Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thick Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Crystallizing Membrane Proteins in Lipidic Mesophases. A Host Lipid Screen

The default lipid for the bulk of the crystallogenesis studies performed to date using the cubic mesophase method is monoolein. There is no good reason, however, why this 18-carbon, cis-monounsaturated monoacylglycerol should be the preferred lipid for all target membrane proteins. The latter come from an array of biomembrane types with varying properties that include hydrophobic thickness, intrinsic curvature, lateral pressure profile, lipid and protein makeup, and compositional asymmetry. Thus, it seems reasonable that screening for crystallizability based on the identity of the lipid creating the hosting mesophase would be worthwhile. For this, monoacylglycerols with differing acyl chain characteristics, such as length and olefinic bond position, must be available. A lipid synthesis and purification program is in place in the author's laboratory to serve this need. In the current study with the outer membrane sugar transporter, OprB, we demonstrate the utility of host lipid screening as a means for generating diffraction-quality crystals. Host lipid screening is likely to prove a generally useful strategy for mesophase-based crystallization of membrane proteins.

59 BASIC BIOLOGICAL SCIENCES↗

Ion beam sputter deposited zinc telluride films

Zinc telluride is of interest as a potential electronic device material, particularly as one component in an amorphous superlattice, which is a new class of interesting and potentially useful materials. Some structural and electronic properties of ZnTe films deposited by argon ion beam sputter depoairion are described. Films (up to 3000 angstroms thick) were deposited from a ZnTe target. A beam energy of 1000 eV and a current density of 4 mA/sq. cm. resulted in deposition rates of approximately 70 angstroms/min. The optical band gap was found to be approximately 1.1 eV, indicating an amorphous structure, as compared to a literature value of 2.26 eV for crystalline material. Intrinsic stress measurements showed a thickness dependence, varying from tensile for thicknesses below 850 angstroms to compressive for larger thicknesses. Room temperature conductivity measurement also showed a thickness dependence, with values ranging from 1.86 x to to the -6/ohm. cm. for 300 angstrom film to 2.56 x 10 to the -1/ohm. cm. for a 2600 angstrom film. Measurement of the temperature dependence of the conductivity for these films showed complicated behavior which was thickness dependent. Thinner films showed at least two distinct temperature dependent conductivity mechanisms, as described by a Mott-type model. Thicker films showed only one principal conductivity mechanism, similar to what might be expected for a material with more crystalline character.

Gulino, D. A.↗

Ion beam sputter deposited zinc telluride films

Zinc telluride is of interest as a potential electronic device material, particularly as one component in an amorphous superlattice, which is a new class of interesting and potentially useful materials. Some structural and electronic properties of ZnTe films deposited by argon ion beam sputter deposition are described. Films (up to 3000 angstroms thick) were deposited from a ZnTe target. A beam energy of 1000 eV and a current density of 4 mA/sq cm resulted in deposition rates of approximately 70 angstroms/min. The optical band gap was found to be approximately 1.1 eV, indicating an amorphous structure, as compared to a literature value of 2.26 eV for crystalline material. Intrinsic stress measurements showed a thickness dependence, varying from tensile for thicknesses below 850 angstroms to compressive for larger thicknesses. Room temperature conductivity measurement also showed a thickness dependence, with values ranging from 1.86 x 10 to the -6th/ohm cm for 300 angstrom film to 2.56 x 10 to the -1/ohm cm for a 2600 angstrom film. Measurement of the temperature dependence of the conductivity for these films showed complicated behavior which was thickness dependent. Thinner films showed at least two distinct temperature dependent conductivity mechanisms, as described by a Mott-type model. Thicker films showed only one principal conductivity mechanism, similar to what might be expected for a material with more crystalline character.

Gulino, D. A.↗

Evaluating the Suitability for CO 2 Storage at the FutureGen 2.0 Site, Morgan County, Illinois, USA

FutureGen 2.0 site will be the first near-zero emission power plant with fully integrated long-term storage in a deep, non-potable saline aquifer in the United States. The proposed FutureGen 2.0 CO 2 storage site is located in northeast Morgan County, Illinois, U.S.A., forty-eight kilometres from the Meredosia Energy Center where a large-scale oxy-combustion demonstration will be conducted. The demonstration will involve > 90% carbon capture, which will produce more than one million metric tons (MMT) of CO 2 per year. The CO 2 will be compressed at the power plant and transported via pipeline to the storage site. To examine CO 2 storage potential of the site, a 1,467m characterization well (FGA#1) was completed in December 2011. The target reservoir for CO 2 storage is the Mt. Simon Sandstone and Elmhurst Sandstone Member of the lower Eau Claire Formation for a combined thickness of 176 m. Confining beds of the overlying Lombard and Proviso Members (upper Eau Claire Formation) reach a thickness of 126 m. Characterization of the target injection zone and the overlying confining zone was based on wellbore data, cores, and geophysical logs, along with surface geophysical (2-D seismic profiles, magnetic and gravity), and structural data collected during the initial stage of the project . Based on this geological model, 3D simulations of CO 2 injection and redistribution were conducted using STOMP-CO 2 , a multiphase flow and transport simulator. After this characterization stage, it appears that the injection site is a suitable geologic system for CO 2 sequestration and that the injection zone is sufficient to receive up to 33 MMT of CO 2 at a rate of 1.1 MMT/yr. GHGT-11 conference

54 ENVIRONMENTAL SCIENCES↗

2169 Steel Waveform Experiments

In support of LLNL efforts to develop multiscale models of a variety of materials, we have performed a set of eight gas gun impact experiments on 2169 steel (21% Cr, 6% Ni, 9% Mn, balance predominantly Fe). These experiments provided carefully controlled shock, reshock and release velocimetry data, with initial shock stresses ranging from 10 to 50 GPa (particle velocities from 0.25 to 1.05 km/s). Both windowed and free-surface measurements were included in this experiment set to increase the utility of the data set, as were samples ranging in thickness from 1 to 5 mm. Target physical phenomena included the elastic/plastic transition (Hugoniot elastic limit), the Hugoniot, any phase transition phenomena, and the release path (windowed and free-surface). The Hugoniot was found to be nearly linear, with no indications of the Fe α – ε phase transition. Releases were non-hysteretic, and relatively consistent between 3- and 5-mm–thick samples (the 3 mm samples giving slightly lower wavespeeds on release). Reshock tests with explosively welded impactors produced clean results; those with glue bonds showed transient releases prior to the arrival of the reshock, reducing their usefulness for deriving strength information. The free-surface samples, which were steps on a single piece of steel, showed lower wavespeeds for thin (1 mm) samples than for thicker (2 or 4 mm) samples. A configuration used for the last three shots allows release information to be determined from these free surface samples. The sample strength appears to increase with stress from ~1 GPa to ~ 3 GPa over this range, consistent with other recent work but about 40% above the Steinberg model.

Furnish, Michael David↗

Overview of the DESI Milky Way Survey

Abstract We describe the Milky Way Survey (MWS) that will be undertaken with the Dark Energy Spectroscopic Instrument (DESI) on the Mayall 4 m telescope at the Kitt Peak National Observatory. Over the next 5 yr DESI MWS will observe approximately seven million stars at Galactic latitudes ∣ b ∣ > 20°, with an inclusive target selection scheme focused on the thick disk and stellar halo. MWS will also include several high-completeness samples of rare stellar types, including white dwarfs, low-mass stars within 100 pc of the Sun, and horizontal branch stars. We summarize the potential of DESI to advance understanding of the Galactic structure and stellar evolution. We introduce the final definitions of the main MWS target classes and estimate the number of stars in each class that will be observed. We describe our pipelines for deriving radial velocities, atmospheric parameters, and chemical abundances. We use ≃500,000 spectra of unique stellar targets from the DESI Survey Validation program (SV) to demonstrate that our pipelines can measure radial velocities to ≃1 km s −1 and [Fe/H] accurate to ≃0.2 dex for typical stars in our main sample. We find the stellar parameter distributions from ≈100 deg 2 of SV observations with ≳90% completeness on our main sample are in good agreement with expectations from mock catalogs and previous surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectral characterization by CVD diamond detectors of energetic protons from high-repetition rate laser for aneutronic nuclear fusion experiments

This work describes the results of experiments performed at the femtosecond ECLIPSE laser facility at CELIA in Bordeaux. Targets constituted by aluminium foils of various thicknesses were irradiated with accelerated protons with energies in the range of interest for p+ 11 B nuclear fusion. Plasma formed in the laser-target interaction were detected using high temperature high radiation resistant diamonds. Time-of-flight measurements were performed by using Chemical Vapor Deposition (CVD) monocrystalline diamonds detectors, which are specifically designed to operate in harsh environments where large ElectroMagnetic Pulses (EMPs) are generated during laser-target interaction. The 1 Hz high repetition rate used for the ECLIPSE laser allowed the collection of a large number of similar shots, giving therefore a large statistics to accurately characterize the energy spectrum of the laser-plasma accelerated protons. As a result, the laser repetitivity at a relatively small intensity permits to improve the signal-to-noise ratio of the detection of the products of low cross-section reactions, such as the p+ 11 B one, by their collection over a large number of similar shots.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron capture of UO 2 targets prepared by spin-coating assisted combustion synthesis

Two uranium dioxide (UO 2 ) targets of (414 ± 23) nm and (1092 ± 93) nm thicknesses were prepared on 6061 aluminum alloy and puratronic grade aluminum backing materials. The targets were deposited with a novel method combining spin coating and solution combustion synthesis (SCS). The target layers consisted of small (3–7 nm) UO 2 grains and uniformly distributed ultra-small (1–3 nm) pores. The prepared targets were tested at the Los Alamos National Laboratory’s LANSCE facility for neutron irradiation damage and suitability for neutron capture experiments. The samples showed no signs of target material loss after the irradiation. However, irradiation caused a significant increase in the grain size (4–10 nm), as well as upward mass diffusion and coalescence of the pores due to the thermal spikes. The magnesium in the aluminum 6061 alloy backing also diffused into the UO 2 layer during neutron irradiation. The structural changes in the target after the irradiation do not affect the data from neutron capture. As a result, the new method can be used more broadly to prepare other actinide targets for nuclear physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systems and methods for interferometric end point detection for a focused ion beam fabrication tool

Various technologies for providing an operator of a focused ion beam (FIB) system with navigational and processing data are described herein. An exemplary system includes a broadband light source and a narrowband light source that emit light to a target of the FIB. An optical detector receives reflections of the broadband light from the target and outputs data that is used to generate two-dimensional images of the target in a region near a location of incidence of the FIB at the target. An interferometer receives reflections of the narrowband light from the target and outputs data indicative of an interference pattern of the narrowband reflections. A computing device computes a thickness of one or more material layers that make up the target based upon the interference pattern. A two-dimensional image of the target and an indication of the computed thickness are then displayed to the operator of the FIB.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dissolution of Additively Manufactured Mo Disks and Structures for Accelerator Based Production of Mo-99

The press-and-sinter approach for production of Mo targets has been successfully tested and demonstrated. The main advantage of this process is that it uses readily available technology and tools that have been tuned for production of various metal and metal oxide targets. However, certain target design specifications, such as dimensional accuracy of the diameter and thickness of the disks, are required for proper fit into a target holder and therefore place strict tolerances on sintered Mo disks intended for accelerator production. Furthermore, having a target composed of multiple disks poses certain challenges for post-irradiation processing, where there is a potential for spillage of individual disks during the manipulation for dissolution inside a processing hot cell. Additive manufacturing (AM), also referred to as 3D printing, provides capabilities to design and build a single-piece Mo target that provides the opportunity for better geometry for optimized production of Mo-99, improved cooling capability, and safer post-irradiation handling. A drawback of AM Mo structures is roughness of finished surfaces, which could reduce the effectiveness of gas cooling systems. Process development for AM Mo structures using selective laser melting is described in work by Gibson and Lowden. For post-irradiation processing, it is important to look at the dissolution behavior of AM Mo structures in comparison to readily dissolved press-and-sinter Mo targets. The dissolution behavior of press-and-sinter targets has been well documented in our previous reports. In this report, we discuss results of dissolution experiments conducted with AM Mo disks and structures (provided by Oak Ridge National Laboratory [ORNL]) in 50% hydrogen peroxide (H 2 O 2 ).

36 MATERIALS SCIENCE↗

Surface and superficial dose dosimetric verification for postmastectomy radiotherapy

In patients given postmastectomy radiotherapy (PMRT), the chest wall is a very thin layer of soft tissue with a low-density lung tissue behind. Chest wall treated in this situation with a high-energy photon beam presents a high dosimetric uncertainty region for both calculation and measurement. The purpose of this study was to measure and to evaluate the surface and superficial doses for patients requiring PMRT with different treatment techniques. An elliptic cylinder cork and superflab boluses were used to simulate the lung and the chest wall, respectively. Sets of computed tomography (CT) images with different chest wall thicknesses were acquired for the study phantom. Hypothetical clinical target volumes (CTVs) were outlined and modified to fit a margin of 1-3 mm, depending on the chest wall thickness, away from the surface for the sets of CT images. The planning target volume (PTV) was initially created by expanding an isotropic 3-mm margin from the CTV, and then a margin of 3 mm was shrunk from the phantom surface to avoid artifact-driven results in the beam-let intensity. Treatment techniques using a pair of tangential wedged fields (TWFs) and 4-field intensity-modulated radiation therapy (IMRT) were designed with a prescribed fraction dose (D{sub p}) of 180 cGy. Superficial dose profiles around the phantom circumference at depths of 0, 1, 2, 3, and 5 mm were obtained for each treatment technique using radiochromic external beam therapy (EBT) films. EBT film exhibits good characteristics for dose measurements in the buildup region. Underdoses at the median and lateral regions of the TWF plans were shown. The dose profiles at shallow depths for the TWF plans show a dose buildup about 3 mm at the median and lateral tangential incident regions with a surface dose of about 52% of D{sub p}. The dose was gradually increased toward the most obliquely tangential angle with a maximum dose of about 118% of D{sub p.} Dose profiles were more uniform in the PTV region for the 4-F IMRT plans. Most of the PTV region had doses >94% of D{sub p} at depths >1 mm. The mean surface dose was about 65% of D{sub p} for the 4-F IMRT plans. The maximum dose for the 4-F IMRT plans was <118.4% of D{sub p}. The application of added bolus has to consider the treatment technique, tumor coverage, and possible skin reactions. For PMRT, if the chest surface and wall are treated adequately, at least 3 mm bolus should be added to the chest wall when tangential beams and 6-MV photon energy are arranged. However, when the surface and superficial regions are not high-risk areas, an IMRT plan with tangential beams and 6-MV photon energy can provide uniform dose distributions within the PTV, spare the skin reaction, and deliver sufficient doses to the chest wall at depths >1 mm.

61 RADIATION PROTECTION AND DOSIMETRY↗

Primary Mineralogical and Chemical Characteristics of the Major K/T and Late Eocene Impact Deposits

Three well-characterized, distal impact deposits at the WT boundary and in upper Eocene sediments serve as a baseline for understanding other proposed impact deposits. All contain abundant spherules, evidence of shock metamorphism, and the largest have significant extraterrestrial components (ETCs). The K/T and the Eocene cpx-spherule (cpxS) deposits are global - likely from the events that produced the 180 km Chicxulub and 100 km Popigai craters. The Eocene North American microtektite (NAM) deposit is regional and likely from the event that produced the 45 km Chesapeake Bay crater. These deposits all contain abundant spherules formed from both shock-melted target and mixtures of target and projectile in the ejecta plume. Spherules constitute most of the mass of the distal ejecta. K/T spherules in regional deposits around the Gulf of Mexico are from low-velocity, target-rich ejecta. These can be a few mm in size and form deposits 10s of cm thick. Globally deposited KIT spherules from the plume (typically a few hundred micron size) are both target- and projectile-rich. When well preserved, the global deposits are 3 mm thick. Eocene cpxS deposits are similar to distal K/T with both target- and projectile-rich varieties (Le., glassy microtektite, and cpx spherules). They are smaller on average than WT spherules, concentrated in the 125-250 micron and smaller fractions. They are invariably bioturbated, but the initial deposit was probably less than 1 mm thick. The NAM are composed entirely of target-rich glass. They are similar in size to the cpxS. Size is an important criterion for distal ejecta because droplet size in the impact plume is proportional to the energy of the impact. Both the JUT and cpxS deposits are characterized by well-defined ETCs, commonly measured by Ir. The total Ir deposited is about 55 ng per square cm in WT sediments, and about 11 ng for the cpxS layer. This 5/1 proportion in Ir is generally consistent with the approx.1.8/1 ratio in crater diameters. The NAM have no significant ETC. This may be a function of the smaller impact. It indicates there was no significant projectile-rich plume deposit.

Kyte, Frank T.↗

Control System For Cryogenic THD Layering At The National Ignition Facility

The National Ignition Facility (NIF) is the world largest and most energetic laser system for Inertial Confinement Fusion (ICF). In 2010, NIF began ignition experiments using cryogenically cooled targets containing layers of the tritium-hydrogen-deuterium (THD) fuel. The 75 {micro}m thick layer is formed inside of the 2 mm target capsule at temperatures of approximately 18 K. The ICF target designs require sub-micron smoothness of the THD ice layers. Formation of such layers is still an active research area, requiring a flexible control system capable of executing the evolving layering protocols. This task is performed by the Cryogenic Target Subsystem (CTS) of the NIF Integrated Computer Control System (ICCS). The CTS provides cryogenic temperature control with the 1 mK resolution required for beta-layering and for the thermal gradient fill of the capsule. The CTS also includes a 3-axis x-ray radiography engine for phase contrast imaging of the ice layers inside of the plastic and beryllium capsules. In addition to automatic control engines, CTS is integrated with the Matlab interactive programming environment to allow flexibility in experimental layering protocols. The CTS Layering Matlab Toolbox provides the tools for layer image analysis, system characterization and cryogenic control. The CTS Layering Report tool generates qualification metrics of the layers, such as concentricity of the layer and roughness of the growth boundary grooves. The CTS activities are automatically coordinated with other NIF controls in the carefully orchestrated NIF Shot Sequence.

42 ENGINEERING↗

Non-DNA radiosensitive targets that initiate persistent behavioral deficits in rats exposed to space radiation

Predicting future CNS risks for astronauts during deep-space missions will rely substantially on ground-based rodent data with space-relevant ions and behaviors. For rats, the accumulated evidence indicates that less densely ionizing radiation, such as 4 He and 12 C ions, induce behavior deficits at lower doses than densely ionizing ions, such as 48 Ti and 56 Fe. However, this observation conflicts with standard somatic radiobiology, in which densely ionizing ions are generally more effective than less densely ionizing ions, and where the DNA/nucleus is the accepted target for radiation-induced tumorigenesis, cytogenetic aberrations, genetic mutations, and reproductive cell death. To gain deeper insight into the subcellular nature of the radiation targets for behavior risks, we compared the effects of dose, fluence, and linear energy transfer (LET) of 4 He and 56 Fe particles using existing datasets for four distinct behavioral outcomes in rats: elevated plus maze (EPM-anxiety), novel object recognition (NOR-memory), operant responding (OR-response to environmental stimuli), and attentional set-shifting (ATSET-cognitive flexibility). We confirmed that less densely ionizing particles (except protons) showed ~100-fold lower threshold doses than densely ionizing particles for behavioral deficits (0.1–1 cGy for 4 He vs. 15–100 cGy for 56 Fe). However, when analyzed by fluence the behavioral responses converged, indicating that 4 He and 56 Fe were equally effective on a per-track basis. When analyzed by LET, there were ~100-fold differences in the LET for maximum effectiveness for behavioral deficits and DNA endpoints (~1 vs ~100 keV/μm, respectively). These unique features of radiation-induced behavioral deficits (high sensitivity to particles in the 1-keV/μm range, insensitivity to protons in the 0.2 keV/μm range, and isofluence dependence for particles with LET>1 keV/μm) provide evidence in support of a new hypothesis of sub-micron sized radiosensitive targets for behavioral effects consistent with the thickness of plasma membranes and/or small subcellular structures, smaller than a whole synapse. Like our behavior findings, mouse immature oocyte killing which is known to have a plasma membrane target was also better explained by fluence, rather than dose. In contrast, fluence analyses for DNA/nuclear endpoints in somatic cells (e.g., tumor induction, chromosome aberrations) showed opposite results, suggesting that behavior targets are not DNA. Our findings raise questions regarding the identity of subcellular targets and the multi-cellular functional unit for behavior risks, low-dose susceptibility, and generalizability from rat to other species and astronauts.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Testing The High-Energy Prompt Neutron Signature At Low Beam Energies

Prompt fission neutrons continue to be examined as a signature for detecting the presence of fissionable material. This technique exploits the neutron energy limitations inherent with photonuclear emissions from non-fissionable material, allowing prompt fission neutrons to be identified and engaged for detecting nuclear material. Prompt neutron signal measurements were acquired with bremsstrahlung endpoint energies of 6 MeV for 18 targets comprised of both fissionable and non-fissionable material; delayed neutron measurements were also collected as a reference. The {sup 238}U target was also shielded with increasing thicknesses of lead or borated polyethylene to compare the resulting detection rates of the prompt and delayed fission neutron signals.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparing Exciton-Polariton Couplings in Two-Dimensional MoS2 Cavities

Exciton-polaritons (EPs) are an emerging approach to achieve strong light-matter coupling and robust quantum phenomena, with application to areas such as photonic neuromorphic computing for instance reservoir computing. 2D transition metal dichalcogenides (TMDs) are promising candidates to host EPs due to their potential for strong coupling as evidenced by large Rabi splitting energies, which in the case of few-layer MoS2 has been demonstrated to reach 293 meV when coupled to the C exciton, placing it in the ultrastrong coupling regime, at room temperature. Here we examine how the Rabi splitting of CVD-grown monolayer MoS2 in a cavity can be optimized by tuning two variables: cavity geometry (thickness of silver and dielectric spacers) and the targeted exciton for coupling (A at about 1.9 eV, B at about 2.06 eV, or C at about 2.9 eV). With the cavity geometry, there is a tradeoff between optical field confinement and transmission. With the targeted exciton, there may be a tradeoff between Rabi splitting and lifetime. Transfer matrix simulations are used to inform how thick the cavity layers need to be, and at what angle measurements should be performed, to achieve Rabi splitting at a certain exciton energy. Experimentally, the Rabi splitting is measured by placing the cavity at a specified angle and measuring the optical reflectance and transmittance. By fitting the data, we find Rabi splittings of 124 meV, 194 meV, and 288 meV for the A, B, and C excitons, respectively, which places them in the strong, and on the edge of the ultrastrong, coupling regime.

exciton-polaritons↗

Minimizing scatter-losses during pre-heat for magneto-inertial fusion targets

Here, the size, temporal and spatial shape, and energy content of a laser pulse for the pre-heat phase of magneto-inertial fusion affect the ability to penetrate the window of the laser-entrance-hole and to heat the fuel behind it. High laser intensities and dense targets are subject to laser-plasma-instabilities (LPI), which can lead to an effective loss of pre-heat energy or to pronounced heating of areas that should stay unexposed. While this problem has been the subject of many studies over the last decades, the investigated parameters were typically geared towards traditional laser driven Inertial Confinement Fusion (ICF) with densities either at 10% and above or at 1% and below the laser's critical density, electron temperatures of 3–5 keV, and laser powers near (or in excess of) 1 × 10 15 W/cm 2 . In contrast, Magnetized Liner Inertial Fusion (MagLIF) currently operates at 5% of the laser's critical density using much thicker windows (1.5–3.5 μm) than the sub-micron thick windows of traditional ICF hohlraum targets. This article describes the Pecos target area at Sandia National Laboratories using the Z-Beamlet Laser Facility as a platform to study laser induced pre-heat for magneto-inertial fusion targets, and the related progress for Sandia's MagLIF program. Forward and backward scattered light were measured and minimized at larger spatial scales with lower densities, temperatures, and powers compared to LPI studies available in literature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bright x-ray stainless steel K-shell source development at the National Ignition Facility

High x-ray conversion efficiency (XRCE) K-shell sources are being developed for high energy density experiments for use as backlighters and for the testing of materials exposed to high x-ray fluxes and fluences. Recently, sources with high XRCE in the K-shell x-ray energy range of iron and nickel were investigated at the National Ignition Facility (NIF). The x-ray conversion efficiency in the 5–9 keV spectral range was determined to be 6.8% ± 0.3%. These targets were 4.1 mm diameter, 4 mm tall hollow epoxy tubes having a 50 μm thick wall supporting a tube of 3 to 3.5 μm thick stainless steel. The NIF laser deposited ∼460 kJ of 3ω light into the target in a 140 TW, 3.3 ns square pulse. The absolute x-ray emission of the source was measured by two calibrated Dante x-ray spectrometers. Time resolved images filtered for the Fe K-shell were recorded to follow the heating of the target. Time integrated high-resolution spectra were recorded in the K-shell range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗