Search NASA⌕ Search

SEARCH · Search NASA

Results for “Unit testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Extraction of Xenon using Enriching Reflux Pressure Swing Adsorption

Measuring radioactive xenon isotopes in the atmosphere is an important technique used for monitoring within the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Several process steps are needed to capture and prepare a xenon sample suitable for transfer to a nuclear detector. These processes include air drying, xenon collection, concentration and purification. The ideal xenon sampling system would be small, have low power consumption, not use consumables (such as helium gas or liquid nitrogen) and be fully automated, robust and dependable. Due to the low concentration of xenon in the air, the most energy intensive part of the gas processing is the first stage collection and concentration. Pacific Northwest National Laboratory has developed a batch mode enriching-reflux pressure-swing-adsorption (ER-PSA) process that shows promise as a xenon collection and concentration technique. The development of this process was guided by finite element models of the process chemistry. The modeling showed minimizing the xenon dispersion in the adsorption columns is critical to achieving a good separation. Prior to hardware construction, models were used to determine appropriate trap dimensions, adsorbent particle size and optimum process variables such as cycle steps, step times, and flow rates. A bench top ER-PSA unit was constructed and testing under various operating conditions has begun. The results obtained in these initial parametric experiments have provided insight into the physics of the process and have refined the mathematical models. The combination of modeling and experiment provides a better understanding of process physics than either experiment or models alone. The bench top system has demonstrated room temperature collection of xenon with a xenon enrichment of 1000 (starting from air) with a modest pressure ratio of 7-10 resulting in an energy efficient separation technique. The technique does not use exotic adsorbents, cryogenic temperatures or high pressure compressors, enabling a small, low power and robust system. This ER-PSA process is an enabling technology for small energy efficient xenon collectors, desirable qualities for next generation international xenon systems.

Williams, Richard M.↗

Aerosol Sampling System for Collection of Capstone Depleted Uranium Particles in a High-Energy Environment

The Capstone Depleted Uranium Aerosol Study was undertaken to obtain aerosol samples resulting from a kinetic-energy cartridge with a large-caliber depleted uranium (DU) penetrator striking an Abrams or Bradley test vehicle. The sampling strategy was designed to (1) optimize the performance of the samplers and maintain their integrity in the extreme environment created during perforation of an armored vehicle by a DU penetrator, (2) collect aerosols as a function of time post-impact, and (3) obtain size-classified samples for analysis of chemical composition, particle morphology, and solubility in lung fluid. This paper describes the experimental setup and sampling methodologies used to achieve these objectives. Custom-designed arrays of sampling heads were secured to the inside of the target in locations approximating the breathing zones of the vehicle commander, loader, gunner, and driver. Each array was designed to support nine filter cassettes and nine cascade impactors mounted with quick-disconnect fittings. Shielding and sampler placement strategies were used to minimize sampler loss caused by the penetrator impact and the resulting fragments of eroded penetrator and perforated armor. A cyclone train was used to collect larger quantities of DU aerosol for chemical composition and solubility. A moving filter sample was used to obtain semicontinuous samples for depleted uranium concentration determination. Control for the air samplers was provided by five remotely located valve control and pressure monitoring units located inside and around the test vehicle. These units were connected to a computer interface chassis and controlled using a customized LabVIEW engineering computer control program. The aerosol sampling arrays and control systems for the Capstone study provided the needed aerosol samples for physicochemical analysis, and the resultant data were used for risk assessment of exposure to DU aerosol.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

1016516285-AA - Handling Frame Assembly Table Structural and Seismic Analysis

Within the NIF (National Ignition Facility) sustainment project, LLNL is replacing all 1,728 blast shields with new ones. Before the new blast shield glass can be installed on NIF, it must pass through the AMOL (Amplifier Main Optics Loop). The AMOL process involves cleaning and coating the glass, assembling it into a Line Replaceable Unit (LRU), and performing testing and inspection. This work will be conducted in the OPFX cleanroom facility (Building 391, Room 1250) and requires several pieces of custom equipment. One key piece of equipment within the loop is the Handling Frame Assembly Table (see Figure 1.1). Its purpose is to assist operators in installing the blast shield glass into handling frames (1014442709) (see Figure 1.2). The table is also used to store handling frame assembly components. The primary components stored are the L-frames (1015208271), which are kept in a drawer underneath the table (see Figure 1.3). The purpose of this safety note is to ensure that the system does not pose a risk of injury to personnel during a seismic event. The system owner is OMST Engineering & Maintenance.

42 ENGINEERING↗

Personnel Certifications for the Design, Installation and Maintenance of Photovoltaic Systems. Final Technical Report

The North American Board of Certified Energy Practitioners (NABCEP) is the most respected, well-established, and widely recognized national certification organization for professionals in the field of renewable energy. NABCEP’s certifications were created to facilitate consumer protection, improve quality assurance, and help employers judge the skills of existing or potential employees. The certifications also allow individuals to differentiate themselves from others in their field and advance their careers while fostering increased recognition of the profession. Since NABCEP’s founding in 2002, all of its certification exams have been administered in paper-and-pencil format twice per year at 30 exam sites around the United States. The biannual test administration and relatively low number of exam sites make it challenging for many qualified renewable energy professionals to take NABCEP’s certification exams. The rigorous nature of the exam, which leads to many candidates failing the exam on their first and sometimes second attempts, combined with the low number of annual test administrations means that anyone who fails will need to wait another six months for the chance to retake the exam. These factors limited the potential growth of NABCEP’s certification programs and the resultant quality assurance within the renewable energy industry. Thanks to a generous grant by the Department of Energy’s Solar Training and Education for Professional (STEP) program, NABCEP recently began updating its Photovoltaic (PV) Installation Professional Exam and developing three new specialty certifications in PV design, PV installation, and PV commissioning & maintenance. One of the primary objectives of this STEP-funded project was to develop the exams using a computer-based testing (CBT) model to increase the number of exam administrations and available exam sites for NABCEP’s certification exams. To successfully complete this project, NABCEP partnered with Castle Worldwide, Inc. With more than 25 years of experience in test development, test administration, analysis of examinations, and has a staff of 70 experienced personnel, NABCEP was confident that Castle’s team was more than qualified to help NABCEP make the transition to CBT examinations. NABCEP and Castle Worldwide jointly developed a project management plan that included key deliverables, scope management, a work breakdown structure, roles and responsibilities, and a project schedule with milestones. The project schedule was carefully monitored to ensure that activities along the critical path were not delayed and, when deemed necessary, the project was crashed to add resources so that activities could occur in parallel. NABCEP and Castle Worldwide staff met weekly to discuss any potential schedule variances and activities which might delay the closing of the project. NABCEP also recruited 46 subject matter experts (SMEs) to work with Castle’s staff on this project. NABCEP staff, SME’s, and Castle staff worked together to develop the Job Task Analyses that form the basis for the certification exams, create new examination forms, conduct passing score studies, and complete a psychometrical analysis of potential exam items. NABCEP’s SMEs utilized Castle’s item development platform during face-to-face meetings, webinars, and remote item authoring to write, review, and approve exam items. Castle also used their software to psychometrically analyze existing exam items to confirm the reliability and validity of the NABCEP’s certification exams. On January 3rd, 2018, NABCEP’s began offering its PV Installation Professional certification exam via CBT. The exam was available at Castle’s nearly 600 exam sites in the United States. A large number of sites will help to ensure better access for solar professionals in rural and remote areas, which drives down the implicit costs of taking the certification exams. Thanks to the STEP grant and the robust partnership between NABCEP and Castle Worldwide, Inc., personnel certifications will be much more accessible and affordable for renewable energy professionals.

14 SOLAR ENERGY↗

Development and application of a standardized flow measurement uncertainty analysis framework to various low-head short-converging intake types across the United States federal hydropower fleet

Turbine discharges at low-head short converging intakes are difficult to measure accurately. The proximity of the measurement section to the intake entrance admits large uncertainties related to asymmetry of the velocity profile, swirl, and turbulence. Existing turbine performance codes [10, 24] do not address this special case and published literature is largely silent on rigorous evaluation of uncertainties associated with this measurement context. The American Society of Mechanical Engineers (ASME) Committee investigated the use of Acoustic transit time (ATT), Acoustic scintillation (AS), and Current meter (CM) in a short converging intake at the Kootenay Canal Generating Station in 2009. Based on their findings, a standardized uncertainty analysis (UA) framework for velocity-area method (specifically for CM measurements) is presented in this paper given the fact that CM is still the most fundamental and common type of measurement system. Typical sources of systematic and random errors associated with CM measurements are investigated, and the major sources of uncertainties associated with turbulence and velocity fluctuations, numerical velocity integration technique (bi-cubic spline), and the number and placement of current meters are being considered for an evaluation. Since the velocity measurements in a short converging intake are associated with complex nonlinear and time varying uncertainties (e.g., Reynolds stress in fluid dynamics), simply applying the law of propagation of uncertainty is known to overestimate the measurement variance while the Monte Carlo method does not. Therefore, a pseudo-Monte Carlo simulation method (random flow generation technique [8]) which was initially developed for the purpose of establishing upstream or initial conditions in the Large-Eddy Simulation (LES) and the Direct Numerical Simulation (DNS) is used to statistically determine uncertainties associated with turbulence and velocity fluctuations. This technique is then combined with a bi-cubic spline interpolation method which converts point velocities into a continuous velocity distribution over the measurement domain. Subsequently the number and placement of current meters are simulated to investigate the accuracy of the estimated flow rates using the numerical velocity-area integration method outlined in ISO 3354 [12]. The authors herein consider that statistics on generated flow rates processed with bi-cubic interpolation and sensor simulations are the combined uncertainties which already accounted for the effects of all those three uncertainty sources. A preliminary analysis based on the current meter data obtained through an upgrade acceptance test of a single unit located in a mainstem plant has been presented.

Smith, Brennan T↗

Progress and investigation on lattice Boltzmann modeling of multiple immiscible fluids or components with variable density and viscosity ratios

Lattice Boltzmann models for simulating multiphase flows are relatively new, and much work remains to be done to demonstrate their ability to solve fundamental test cases before they are considered for engineering problems. From this perspective, a hydrodynamic lattice Boltzmann model for simulating immiscible multiphase flows with high density and high viscosity ratios, up to O(1000) and O(100) respectively, is presented and validated against analytical solutions. The method is based on a two phase flow model with operators extended to handle N immiscible fluids. The current approach is O(N) in computational complexity for the number of different gradient approximations. This is a major improvement, considering the O(N{sup 2}) complexity found in most works. A sequence of systematic and essential tests have been conducted to establish milestones that need to be met by the proposed approach (as well as by other methods). First, the method is validated qualitatively by demonstrating its ability to address the spinodal decomposition of immiscible fluids. Second, the model is quantitatively verified for the case of multilayered planar interfaces. Third, the multiphase Laplace law is studied for the case of three fluids. Fourth, a quality index is developed for the three-phase Laplace–Young’s law, which concerns the position of the interfaces between the fluids resulting from the different surface tensions. The current model is compatible with the analytical solution, and is shown to be first order accurate in terms of this quality index. Finally, the multilayered Couette’s flow is studied. In this study, numerical results can recover the analytical solutions for all the selected test cases, as long as unit density ratios are considered. For high density and high viscosity ratios, the analytical solution is recovered for all tests, except that of the multilayered Couette’s flow. Numerical results and a discussion are presented for this unsuccessful test case. It is believed that other LB models may have the same problem in addressing the simulation of multiphase flows with variable density ratios.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fit for Purpose Remote Technology Decommissioning Solutions - 18630

The Magnox Decommissioning Project is actively progressing clean-up and decommissioning of 12 reactor sites across England, Scotland and Wales. Funded and directed by the United Kingdom's Nuclear Decommissioning Authority (NDA) and managed by the Cavendish Fluor Partnership (CFP), the Magnox Decommissioning Project introduces a wide range of radiological and industrial hazards warranting deployment of remote technologies to safely de-inventory, decontaminate and decommission a vast array of nuclear facilities. The Magnox Decommissioning Project encompasses 22 former Magnox nuclear power production reactors across 10 reactor sites and five research/test reactors at two former research sites. Decommissioning activities have been underway at some sites for nearly 20 years with early focus on retrieving and stabilising wastes and draining and stabilising spent fuel ponds. The Magnox decommissioning strategy invokes a programme perspective to drive consistency in tackling similar decommissioning and waste challenges across multiple sites. Programme central teams have worked with technology suppliers to foster learning from industry experience to develop and deploy tooling and robotics. The programme approach has also facilitated learning from one site to the next. In many cases, this central programme approach has promoted an evolution of technologies resulting in optimisation of simple remote tooling. In other instances, collaboration with suppliers is producing state-of-the-art technologies to tackle more unique challenges including, most recently, early demonstration of laser cutting for reactor vessel dismantling. This paper will outline the programme management approach and the scalable optioneering process Magnox employs to select the engineered controls and technologies used in decommissioning and waste management activities. It will provide an overview of the broad range of remote tooling and robotics deployed across the 12 Magnox sites by exploring some specific examples. Lastly, the paper will summarise key lessons learned in the now extensive history of selecting and using remote technologies to decommission Magnox nuclear facilities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-D-210-07: The Dependence On Acoustic Velocity of Medium On the Needle Template and Electronic Grid Alignment in Ultrasound QA for Prostate Brachytherapy

Purpose: To analyze the impact on acoustic velocity (AV) of two different media (water and milk) using the needle template/electronic grid alignment test. Water, easily available, makes a good material to test the alignment of the template and grid although water’s AV (1498 m/s at 25°C) is significantly different from tissue (1540 m/s). Milk, with an AV much closer (1548 m/s) to prostate tissue, may be a good substitute for water in ultrasound quality assurance testing. Methods: Tests were performed using a Hitachi ultrasound unit with a mechanical arrangement designed to position needles parallel to the transducer. In this work, two materials – distilled water and homogenized whole milk (AVs of 1498 and 1548 m/s at 25°C) were used in a phantom to test ultrasound needle/grid alignment. The images were obtained with both materials and analyzed for their placement accuracy. Results: The needle template/electronic grid alignment tests showed displacement errors between measured and calculated values. The measurements showed displacements of 2.3mm (water) and 0.4mm (milk), and 1.6mm (water) and 0.3mm (milk) at depths of 7cm and 5cm respectively from true needle positions. The calculated results showed a displacement of 2.36 mm (water); 0.435mm (milk), and 1.66mm (water) and 0.31mm (milk) at a depth of 7cm and 5cm respectively. The displacements in the X and Y directions were also calculated. At depths of 7cm and 5cm, the (ΔX,ΔY) displacements in water were (0.829mm, 2.21mm) and (0.273mm, 1.634mm) and for milk were (0.15mm, 0.44mm) and (0.05mm, 0.302mm) respectively. Conclusion: The measured and calculated values were in good agreement for all tests. They show that milk provides superior results when performing needle template and electronic grid alignment tests for ultrasound units used in prostate brachytherapy.

60 APPLIED LIFE SCIENCES↗

Final Status Survey Report for Corrective Action Unit 117 - Pluto Disassembly Facility, Building 2201, Nevada National Security Site, Nevada

This document contains the process knowledge, radiological data and subsequent statistical methodology and analysis to support approval for the radiological release of Corrective Action Unit (CAU) 117 – Pluto Disassembly Facility, Building 2201 located in Area 26 of the Nevada National Security Site (NNSS). Preparations for release of the building began in 2009 and followed the methodology described in the Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM). MARSSIM is the DOE approved process for release of Real Property (buildings and landmasses) to a set of established criteria or authorized limits. The pre-approved authorized limits for surface contamination values and corresponding assumptions were established by DOE O 5400.5. The release criteria coincide with the acceptance criteria of the U10C landfill permit. The U10C landfill is the proposed location to dispose of the radiologically non-impacted, or “clean,” building rubble following demolition. However, other disposition options that include the building and/or waste remaining at the NNSS may be considered providing that the same release limits apply. The Final Status Survey was designed following MARSSIM guidance by reviewing historical documentation and radiological survey data. Following this review a formal radiological characterization survey was performed in two phases. The characterization revealed multiple areas of residual radioactivity above the release criteria. These locations were remediated (decontaminated) and then the surface activity was verified to be less than the release criteria. Once remediation efforts had been successfully completed, a Final Status Survey Plan (10-015, “Final Status Survey Plan for Corrective Action Unit 117 – Pluto Disassembly Facility, Building 2201”) was developed and implemented to complete the final step in the MARSSIM process, the Final Status Survey. The Final Status Survey Plan consisted of categorizing each individual room into one of three categories: Class 1, Class 2 or Class 3 (a fourth category is a “Non-Impacted Class” which in the case of Building 2201 only pertained to exterior surfaces of the building.) The majority of the rooms were determined to fall in the less restrictive Class 3 category, however, Rooms 102, 104, 106, and 107 were identified as containing Class 1 and 2 areas. Building 2201 was divided into “survey units” and surveyed following the requirements of the Final Status Survey Plan for each particular class. As each survey unit was completed and documented, the survey results were evaluated. Each sample (static measurement) with units of counts per minute (cpm) was corrected for the appropriate background and converted to a value with units of dpm/100 cm2. With a surface contamination value in the appropriate units, it was compared to the surface contamination limits, or in this case the derived concentration guideline level (DCGLw). The appropriate statistical test (sign test) was then performed. If the survey unit was statistically determined to be below the DCGLw, then the survey unit passed and the null hypothesis (that the survey unit is above limits) was rejected. If the survey unit was equal to or below the critical value in the sign test, the null hypothesis was not rejected. This process was performed for all survey units within Building 2201. A total of thirty-three “Class 1,” four “Class 2,” and one “Class 3” survey units were developed, surveyed, and evaluated. All survey units successfully passed the statistical test. Building 2201 meets the release criteria commensurate with the Waste Acceptance Criteria (for radiological purposes) of the U10C landfill permit residing within NNSS boundaries. Based on the thorough statistical sampling and scanning of the building’s interior, Building 2201 may be considered radiologically “clean,” or free of contamination.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hermes-3: Multi-component plasma simulations with BOUT++

A new open source tool for fluid simulation of multi-component plasmas is presented, based on a flexible software design that is applicable to scientific simulations in a wide range of fields. Hermes-3 is built on plasma simulation framework BOUT++, consolidating earlier SD1D and Hermes models into a single code that can be configured at run-time to solve plasma models in 1D, 2D or 3D, either for transport (steady-state) or turbulent (time-evolving) problems, with an arbitrary number of ion and neutral species. Here, we describe the improved numerical algorithms and software design that have been implemented in Hermes-3. To demonstrate the capabilities of this tool, applications relevant to the boundary of tokamak plasmas are presented: 1D simulations of diveror plasmas evolving equations for all charge states of neon and deuterium; 2D transport simulations of tokamak equilibria in single-null X-point geometry with plasma ion and neutral atom species; and simulations of the time-dependent propagation of plasma filaments (blobs). Hermes-3 is publicly available on Github under the GPL-3 open source license. The repository includes documentation and a suite of unit, integrated and convergence tests.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation therapy of synchronous bilateral breast carcinoma (SBBC) using multiple techniques

The purpose of this study was to establish intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) treatment plans for synchronous bilateral breast cancer (SBBC) and to compare those plans with the previous treatment plans using 3D conformal radiation therapy (3DCRT). The differences among the treatments were also statistically compared regarding dosimetry distribution and treatment efficiency. The research was conducted with 10 SBBC patients. The study established IMRT (12 fields with a single isocenter) and VMAT (2 partial arcs with a single isocenter) treatment plans for SBBC patients and then compared those plans with 3DCRT (8 fields with multiple isocenters). The plans were evaluated based on a dose-volume histogram analysis. For planning target volumes (PTVs), the mean doses and the values of V{sub 95%}, V{sub 105%}, conformity index, and homogeneity index were reported. For the organs at risk, the analysis included the mean dose, maximum dose, and V{sub XGy}, depending on the organs (lungs, heart, and liver). To objectively evaluate the efficiency of the treatment plans, each plan's beam times, treatment times (including set-up time), and monitor units were compared. Tukey test and one-way analysis of variance were used to compare the PTV and organs at risk values of the 3 techniques. Additionally, the independent-samples t-test was used to compare the 2 techniques (IMRT and VMAT) based on the values of Rt. PTV and Lt. PTV (p mean and of approximately 5.7% in V{sub 95%} dose distribution compared with 3DCRT. In comparison to VMAT, 3DCRT showed about 3.0% higher dose distribution in D{sub mean} and V{sub 95%}. IMRT was the best in terms of conformity index and homogeneity index (p 30Gy and V{sub 40Gy} was approximately 70% lower for IMRT and approximately 40% lower for VMAT than for 3DCRT. For distribution volumes of low doses such as V{sub 5%} and V{sub 10%}, that for 3DCRT was approximately 60% smaller than for IMRT and approximately 70% smaller than for VMAT. Comparison between IMRT and VMAT showed that the IMRT was superior in all distribution factors. VMAT showed better treatment efficiency than 3DCRT or IMRT. Among the SBBC radiotherapy treatment plans, IMRT was superior to 3DCRT and VMAT in terms of PTV dose distribution, whereas VMAT showed the most outstanding treatment efficiency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

International fuel performance study of fresh fuel experiments for PCMI effects during RIA experiments

This paper presents the results of High-burnup Experiments for Reactivity-initiated Accident (HERA) Modeling & Simulation (M&S) exercise. The HERA project under the Nuclear Energy Agency (NEA) Second Framework for Irradiation Experiments (FIDES-II) program is focused on studying Light Water Reactor (LWR) fuel behavior during Reactivity-Initiated Accident (RIA) conditions. The Part I M&S cases are based on a series of tests in the Transient Reactor Test (TREAT) facility in the United States and the Nuclear Safety Research Reactor (NSRR) in Japan. The purpose of this work is to evaluate the test design to accomplish its goals in establishing clearer understanding of the effects of power pulse width during RIA conditions. Further, the blind predictions using various computational tools have been performed and compared amongst to interpret the behaviors of high burnup fuels during RIA. While many international participants evaluate the thermal–mechanical behavior of fuel rod under different conditions, a considerable scatter of outputs comes out for the cases due to the disparity between codes in predicting mechanical behaviors. In general, however, the results of thermal–mechanical analysis elaborate that nominal design conditions the shorter pulse width tests in NSRR should cause cladding failures while the TREAT tests appear to have more split prediction of failure or not. Furthermore, the sensitivity analysis varying key testing parameters reveals the considerable effect of power pulse width and total energy deposition on prediction of fuel rod failure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Stream Temperature Prediction in a Shifting Environment: Explaining the Influence of Deep Learning Architecture

Stream temperature is a fundamental control on ecosystem health. Recent efforts incorporating process guidance into deep learning models for predicting stream temperature have been shown to outperform existing statistical and physical models. This performance is in part because deep learning architectures can actively learn spatiotemporal relationships that govern how water and energy propagate through a river network. However, exploration of how spatiotemporal awareness and process guidance influence a model's generalizability under shifting environmental conditions such as climate change is limited. Here, we use Explainable Artificial Intelligence (XAI) to interrogate how differing deep learning architectures affect a model's learned spatial and temporal dependencies, and how those learned dependencies affect a model's ability to maintain high accuracy when applied to unseen environmental conditions. Using the Delaware River Basin in the northeastern United States as a test case, we compare two spatiotemporally aware process–guided deep learning models for predicting stream temperature (a recurrent graph convolution network—RGCN, and a temporal convolution graph model—Graph WaveNet). Both models achieve equally high predictive performance when testing data are well represented in the training data (test root mean squared errors of 1.64°C and 1.65°C); however, Graph WaveNet significantly outperforms RGCN in 4 out of 5 experiments where test partitions represent different types of unseen environmental conditions. XAI results show that the architecture of Graph WaveNet leads to learned spatial relationships with greater fidelity to physical processes, and that this fidelity improves the generalizability of the model when applied to shifting and/or unseen environmental conditions.

54 ENVIRONMENTAL SCIENCES↗

Fusing subnational with national climate action is central to decarbonization: the case of the United States

Approaches that root national climate strategies in local actions will be essential for all countries as they develop new nationally determined contributions under the Paris Agreement. The potential impact of climate action from non-national actors in delivering higher global ambition is significant. Sub-national action in the United States provides a test for how such actions can accelerate emissions reductions. We aggregated U.S. state, city, and business commitments within an integrated assessment model to assess how a national climate strategy can be built upon non-state actions. We find that existing commitments alone could reduce emissions 25% below 2005 levels by 2030, and that enhancing actions by these actors could reduce emissions up to 37%. We show how these actions can provide a stepped-up basis for additional federal action to reduce emissions by 49%—consistent with 1.5 °C. Our analysis demonstrates sub-national actions can lead to substantial reductions and support increased national action.

54 ENVIRONMENTAL SCIENCES↗

Establishing a Proficiency Testing Scheme for Drinking Water Radiochemistry

As part of its international water proficiency testing (PT) scheme, 'Aquacheck', the LGC Proficiency Testing Group has established a new water radiochemistry PT scheme. The PT scheme is aimed at laboratories who undertake radiochemical analysis on drinking water samples as part of an environmental monitoring programme. Following a scheme design and feasibility study, the new scheme was established to monitor the laboratory performance of participants undertaking the determination of gross alpha, gross beta and tritium activity. Three rounds of the new water radiochemistry PT scheme are now complete. This paper explains the process of establishing such a scheme, reviews the results so far, and addresses future development of the scheme.

54 ENVIRONMENTAL SCIENCES↗

Fast, multi-channel real-time processing of signals with microsecond latency using graphics processing units

Fast, digital signal processing (DSP) has many applications. Typical hardware options for performing DSP are field-programmable gate arrays (FPGAs), application-specific integrated DSP chips, or general purpose personal computer systems. This paper presents a novel DSP platform that has been developed for feedback control on the HBT-EP tokamak device. The system runs all signal processing exclusively on a Graphics Processing Unit (GPU) to achieve real-time performance with latencies below 8 μs. Signals are transferred into and out of the GPU using PCI Express peer-to-peer direct-memory-access transfers without involvement of the central processing unit or host memory. Tests were performed on the feedback control system of the HBT-EP tokamak using forty 16-bit floating point inputs and outputs each and a sampling rate of up to 250 kHz. Signals were digitized by a D-TACQ ACQ196 module, processing done on an NVIDIA GTX 580 GPU programmed in CUDA, and analog output was generated by D-TACQ AO32CPCI modules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Media comparison of filtration with Hanford tank AP-107 supernate

The present experimental work was performed in order to investigate media performance in both cross-flow and dead-end filtration on 9 L of Hanford tank AP-107 supernatant. Media grades 0.1 and 5 were tested for each the cross-flow filter (CFF) and dead-end filter (DEF). The CFFs were tested in the cells unit filter (CUF) system in recycle mode and the DEFs (in-line and disc) were used to dewater the feed. Visual inspection of the feed material indicated essentially no settled insoluble solids in the feed material. The 5 micron grade cross flow filter produced stable filter fluxes while the flux for the 0.1 micron grade material steadily decayed. The 5 media grade BDEF (backpulsed dead-end filter) was effective at removing solids from the AP-107 feed and when backpulsed, fully restored the filter flux, indicating that the solids did not irreversibly foul the filter. The 0.1 media grade DEF was used to filter the final 2 liters of AP-107 feed drained from the CUF and collect solids on the filter media. Additional DEF filtering was performed on 4 L of BDEF permeate in order to assess whether small particles that cause fouling in the 0.1 media grade filter passed through the 5 media grade filter. There was no indication of fouling and limited solids were observed on the filter. In conclusion, a direct comparison of filtration rates between the 0.1 and 5 media grade filters for both the CFF and DEF showed the 5 media grade filter flux was, on average, 200 times higher than the 0.1 media grade filter while still effectively filtering the solids.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Gauge invariance and reciprocity in quantum mechanics

Reciprocity in wave propagation usually refers to the symmetry of the Green's function under the interchange of the source and the observer coordinates, but this condition is not gauge invariant in quantum mechanics, a problem that is particularly significant in the presence of a vector potential. Several possible alternative criteria are given and analyzed with reference to different examples with nonzero magnetic fields and/or vector potentials, including the case of a multiply connected spatial domain. It is shown that the appropriate reciprocity criterion allows for specific phase factors separable into functions of the source and observer coordinates and that this condition is robust with respect to the addition of any scalar potential. In the Aharonov-Bohm effect, reciprocity beyond monoenergetic experiments holds only because of subsidiary conditions satisfied in actual experiments: the test charge is in units of e and the flux is produced by a condensate of particles with charge 2e.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗