At least 829 records · Page 46

Individual NSLS-II Multipole Magnet Alignment by Laser Trackers

The magnet alignment of the 90 th and final multipole girder assembly was completed January 17 th , 2013. Our procedure of “rough” pre-alignment by laser trackers and final alignment by vibrating wire & “Differential Variable Reluctance Transducers” (DVRT) has been quite successful, achieving magnet to magnet alignment well under the 30 micron specification. The pre-alignment accuracy is verified by the initial scan from the vibrating wire. The alignment residuals can be calculated from the offsets of a best fit line. The results are impressive, especially considering the environment of the Building 902 Annex (which has a large bay door that would open during pre-alignment, without fail), the sloppiness of the magnets’ fiducials, and especially the fact that the girders were pre-aligned to their mechanical centers, but the vibrating wire reports the magnetic centers which may be considerably different. This result hints at the potential feasibility of alignment with laser trackers for replacement magnets of NSLS-II and maybe even all magnets of future accelerators. But, it is difficult to predict the achievable accuracy until the main three error sources (a.k.a. Survey group excuses) are eliminated: measuring environment, bad magnet fiducials, and mechanical/magnetic center differences. The test performed on a large aperture quadrupole on girder assembly C19G4 was designed to answer the following questions with the aforementioned error sources either eliminated or simulated: 1) How accurately can a NSLS-II multipole be realigned after repair or other disturbance given the existing fiducials? 2) How accurately can a replacement NSLS-II multipole be installed in situ if its magnetic center is known relative to good fiducials? 3) If the current NSLS-II spares are never magnetically fiducialized, how well can they be installed using only mechanical data? 4) Could the magnets of a future accelerator (with similar alignment specifications as NSLS-II) be aligned using commercially available metrology instruments? This paper will answer these questions.

36 MATERIALS SCIENCE↗

Modeling the Electronic Absorption Spectra of the Indocarbocyanine Cy3

Accurate modeling of optical spectra requires careful treatment of the molecular structures and vibronic, environmental, and thermal contributions. The accuracy of the computational methods used to simulate absorption spectra is limited by their ability to account for all the factors that affect the spectral shapes and energetics. The ensemble-based approaches are widely used to model the absorption spectra of molecules in the condensed-phase, and their performance is system dependent. The Franck–Condon approach is suitable for simulating high resolution spectra of rigid systems, and its accuracy is limited mainly by the harmonic approximation. In this work, the absorption spectrum of the widely used cyanine Cy3 is simulated using the ensemble approach via classical and quantum sampling, as well as, the Franck–Condon approach. The factors limiting the ensemble approaches, including the sampling and force field effects, are tested, while the vertical and adiabatic harmonic approximations of the Franck–Condon approach are also systematically examined. Our results show that all the vertical methods, including the ensemble approach, are not suitable to model the absorption spectrum of Cy3, and recommend the adiabatic methods as suitable approaches for the modeling of spectra with strong vibronic contributions. We find that the thermal effects, the low frequency modes, and the simultaneous vibrational excitations have prominent contributions to the Cy3 spectrum. The inclusion of the solvent stabilizes the energetics significantly, while its negligible effect on the spectral shapes aligns well with the experimental observations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Speed-dependent effects in the near-infrared spectrum of self-colliding H{sub 2}{sup 18}O molecules

The absorption line shape of a given H{sub 2}{sup 18}O vibration-rotation line at 1.38 {mu}m was deeply investigated using a spectroscopic approach based upon the use of a pair of offset-frequency locked extended-cavity diode lasers. This dual-laser apparatus ensures extreme levels of accuracy in controlling and measuring any variation of the laser frequency around a given absolute reference. As a result, high levels of precision and accuracy were reached in the observation of a molecular absorption line shape in the near infrared. A variety of semiclassical models, accounting for Dicke narrowing and speed-dependent effects, were implemented and tested in order to describe the physical situation of self-colliding H{sub 2}{sup 18}O molecules. Our study demonstrates that the molecular confinement alone is unable to explain entirely the departures from the Voigt profile and that the speed dependence of pressure-induced broadening and shift cannot be ignored, even in the case of pure water samples at relatively small pressures. The absorption spectrum was successfully interpolated using the uncorrelated version of the speed-dependent Galatry profile, with a hypergeometric dependence on the absorber speed for both pressure broadening and pressure shift parameters, thus reaching an agreement between theory and experiment at the level of 5x10{sup -5}.

74 ATOMIC AND MOLECULAR PHYSICS↗

Experimental Verification of Pulse Shaping in Elastic Metamaterials Under Impact Excitation

Here, we present experimental verification of pulse shaping in elastic metamaterials together with a procedure to design, fabricate, and verify metamaterial pulse shapers under impact excitation. The split Hopkinson pressure bar (SHPB) test, a fundamental dynamic test introduced more than 70 years ago, often incorporates pulse shaping as a means to alter a stress wave, providing the primary motivation for the presented study. Elastic metamaterials hold promise for enhancing conventional pulse shaping abilities and improving capabilities of the SHPB test. We first design the pulse shaper by numerically optimizing its response using finite element analysis. The pulse shaper consists of repeated unit cells based on a combination of a phononic crystal and a local resonator. Then, we fabricate and test pulse shaper candidates to validate the procedural efficacy. An iterative element corrects inaccuracies in input force and material properties and allows convergence on an appropriate pulse shaper. We carry out this procedure by designing pulse shapers fabricated from 3D-printed polylactic acid (PLA) to achieve an extended dwell acceleration pulse shape. In experimental impact tests, the procedure results in rise, dwell, and fall behaviors comparable to that predicted, effectively confirming the efficacy of the presented procedure and verifying the performance of metamaterial-based pulse shapers.

36 MATERIALS SCIENCE↗

Experimental validation of the Finite Element-Multibody model of a cryomodule during road transportation

The present activity aims to test the Transportation Tooling (TT) designed for the Cryomodule SSR1 at Fermilab facilities. The tests consisted of road transportation trials of a cryomodule sub-assembly, suspended on a truck using the designed TT. The truck drove along a path inside Fermilab facilities. The trial was performed at an approximate speed of about 25 km/h, which is close to the transportation conditions of the complete Cryomodule. Several accelerometers were mounted on the Transportation Tooling frame and the cryomodule sub-assembly. This allowed comparing the vibration behavior of the inner frame of the TT with the solicitation coming from the truck loading bed, to assess the filtering capabilities of the tooling. Also, the acceleration of the main components could be monitored during the whole transportation, to obtain a validation of the developed numerical model.

43 PARTICLE ACCELERATORS↗

Analyzing data from a PDV microphone

Photon Doppler Velocimetry (PDV) is used at Los Alamos National Laboratory to measure extremely fast velocities (on the order of 0.01 - 5 km/s) of projectiles during material testing procedures. This kind of testing is extremely important to understand how materials behave in extreme conditions (such as in nuclear explosions). PDV data is created by summing an incident beam with a Doppler shifted reflection, forming a beat frequency. The beat frequency is directly proportional to the velocity of the reflecting surface. We explored a new way of using PDV: measuring slow velocities (less than 1 m/s). The principle method we used was to measure vibrations in a Mylar sheet due to incident sound waves. I analyzed these files using both my own coding as well as a program designed at NSTec for this purpose. Analysis included performing Fourier Transforms, extracting velocity as a function of time, and playing the velocity function through a speaker to recreate the initial sound. We were able to create a successful microphone, though playback quality was poor. The limiting factor was the low velocity of the Mylar sheet, which was about 0.2 m/s. Other methods are now being explored to extract velocity data in a more efficient manner. During this project I gained extensive experience in programming, data analysis, problem solving, and communication. I learned that one must be creative in order to solve complex problems, approaching them from various angles. I also gained a lot of practice working on a team, which consisted of a high school student, another college intern, and our mentor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of maximum strain of steel beam structures based on average strains from vibrating wire strain gages

In structural health monitoring, the safety of steel beam structures can be assessed by comparing the measured maximum stress and the allowable stress of the beam calculated by a design code. For the case of a steel beam subjected to variable lateral loadings, many difficulties exist in measuring the maximum stress in a beam with point sensors that can measure the strain only at a local point of a beam since the location and magnitude of the maximum stress induced in a beam by the loading change. Although traditional strain sensors can measure the strain only at a local point, a vibrating wire strain gage (VWSG) that measures integrated strains over its gage length can consider the variation of strains due to variable loadings. This paper presents an estimation model to determine the maximum strains or stresses in a steel beam based on average strains measured using VWSGs. The model is derived by defining the relation between the average strains measured using VWSGs and the maximum strains of beams. The model is experimentally tested by comparing the maximum strain directly obtained from electrical strain gages and the estimated maximum strain based on the average strain from VWSGs.

42 ENGINEERING↗

$\gamma$-Unstable Bohr Hamiltonian with sextic potential for odd-A nuclei

We report in this paper, odd-A nuclei in the vibrational to γ-soft transitional region are studied in the collective model, in which the odd-A system is described by the Bohr Hamiltonian with the quasi exactly solvable sextic β-part potential for the even-even core coupled with a single nucleon in a j = 3/2 orbit via the β-independent five-dimensional spin-orbit interaction and the total angular momentum degeneracy breaking term. To test the validity of the coupling scheme, we use the model to reproduce experimentally available level energies and B(E2) values of 187,189,191,193,195 Ir. It is clearly shown from both the level energies and the known B(E2) values for 191,193I r fitted that the model with the β-independent five-dimensional spin-orbit interaction and the total angular momentum degeneracy breaking term seems adequate to describe the low-lying level pattern and the structure of these odd-A nuclei.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mechanical joining with self piercing solid-rivets at elevated tool velocities

In the present paper the influence of a higher setting velocity in the joining process of self piercing solid-rivets is shown. In the conventional process tool velocities well below 1 m/s are common. The present research results show the potential of increasing them in the range of about 5 m/s. The results are especially relevant for joining high-strength steels. These steel sheets often cause problems in the process of riveting mixed materials, e. g. aluminium-steel compound. The high strength of the steel sometimes leads to undesirable material flow in the joining process or unwanted burr development. These effects, which are described in detail in the article, can be reduced significantly for the investigated cases by the use of higher tool velocities. Using a high speed camera and a load cell, a test setup based on a drop tower was realized. It was used to time the force signals and the motion profile of the high speed riveting process. The results of the force analysis show an oscillating force progression. Within a numerical research the principal effects influencing the results of the riveting process can be shown. It was found that the pulse-like force transmission between riveting machine and punch, results in various vibrations especially of long and thin tool parts. Hence the rivet penetrates the sheet metal with non-uniform velocities. As a result the early indentation of die into the lower sheet metal at the beginning of the process is reduced, so that the final process step provides a sufficient material flow into the circular rivet groove. A strain-rate dependent process model with elastic tool properties and consideration of inertia effects is presented.

36 MATERIALS SCIENCE↗

Cooling the dark energy camera instrument

DECam, camera for the Dark Energy Survey (DES), is undergoing general design and component testing. For an overview see DePoy, et al in these proceedings. For a description of the imager, see Cease, et al in these proceedings. The CCD instrument will be mounted at the prime focus of the CTIO Blanco 4m telescope. The instrument temperature will be 173K with a heat load of 113W. In similar applications, cooling CCD instruments at the prime focus has been accomplished by three general methods. Liquid nitrogen reservoirs have been constructed to operate in any orientation, pulse tube cryocoolers have been used when tilt angles are limited and Joule-Thompson or Stirling cryocoolers have been used with smaller heat loads. Gifford-MacMahon cooling has been used at the Cassegrain but not at the prime focus. For DES, the combined requirements of high heat load, temperature stability, low vibration, operation in any orientation, liquid nitrogen cost and limited space available led to the design of a pumped, closed loop, circulating nitrogen system. At zenith the instrument will be twelve meters above the pump/cryocooler station. This cooling system expected to have a 10,000 hour maintenance interval. This paper will describe the engineering basis including the thermal model, unbalanced forces, cooldown time, the single and two-phase flow model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design, Assembly, and Testing of a Photon Doppler Velocimetry Probe

A novel fiber-optic probe measures the velocity distribution of an imploding surface along many lines of sight. Reflected light from each spot on the moving surface is Doppler shifted with a small portion of this light propagating backwards through the launching fiber. The reflected light is mixed with a reference laser in a technique called photon Doppler velocimetry, providing continuous time records. Within the probe, a matrix array of 56 single-mode fibers sends light through an optical relay consisting of three types of lenses. Seven sets of these relay lenses are grouped into a close-packed array allowing the interrogation of seven regions of interest. A six-faceted prism with a hole drilled into its center directs the light beams to the different regions. Several types of relay lens systems have been evaluated, including doublets and molded aspheric singlets. The optical design minimizes beam diameters and also provides excellent imaging capabilities. One of the fiber matrix arrays can be replaced by an imaging coherent bundle. This close-packed array of seven relay systems provides up to 476 beam trajectories. The pyramid prism has its six facets polished at two different angles that will vary the density of surface point coverage. Fibers in the matrix arrays are angle polished at 8{sup o} to minimize back reflections. This causes the minimum beam waist to vary along different trajectories. Precision metrology on the direction cosine trajectories is measured to satisfy environmental requirements for vibration and temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Warm Unit Stand Analysis for Proton Improvement Project II

The Proton Improvement Project II, commonly referred to as PIP II, is a linear accelerator overhaul at Fermilab to eventually double the output of its existing proton beam to continue to be the leading force in high energy physics. The proton beam is created through a series of high frequency cryomodules that must be connected utilizing a combination of magnets and vacuum pumps to ensure the beam is properly aligned. A housing mechanism for the magnets and vacuum pumps (Warm Units) will be placed between the cryomodules for realignment and require multiple stages of 6 degree-of-freedom adjustment options, to ensure that the beam alignment can fit all realistic requirements. Extensive testing and design modifications on the Warm Unit stand was completed to confirm not only the strength of the unit in nominal configuration, but also at each possible adjustment orientation for each 6 degree-of-freedom option. Structural analysis was also completed for various unique loading conditions i ncluding transportation loading and confirming the unit satisfies international building code. Simultaneously, testing and design modifications were done to confirm that the frequency modes of the system resided outside of concern ranges, which is determined by Fermilab safety codes and is set to exceed 15 Hz. Design changes that simultaneously stiffen the system to raise the lowest frequency modes while expanding access for technicians and allow for easier fabrication were developed and implemented into the Warm Unit stand. Various relationships between the design changes and the overall vibrational patterns were also developed for future use and study as the rest of PIP II matures.

43 PARTICLE ACCELERATORS↗

Self-supervised and multi-fidelity learning for extended predictive soil spectroscopy

Infrared spectroscopy is a cost-effective, non-destructive, and environmentally benign technology that is increasingly recognized as an important solution for meeting the global demand for soil data. While both near-infrared (NIR) and mid-infrared (MIR) diffuse reflectance spectroscopy enable rapid estimation of soil properties, they present a significant trade-off: NIR offers superior scalability and lower operational costs, whereas MIR provides higher analytical fidelity by capturing fundamental molecular vibrations. In this study, we propose a self-supervised, multi-fidelity learning framework designed to bridge this gap. Our approach leverages large-scale MIR spectral libraries to learn a compact, transferable latent representation, into which NIR spectra are subsequently aligned for downstream prediction. The workflow consists of pretraining a latent model on a large MIR library, adapting the representation using a smaller paired NIR–MIR dataset, and evaluating generalization on an independent external test set. Across a range of chemical and physical soil properties, we found that MIR-derived embeddings improved prediction accuracy relative to baseline models that used raw MIR inputs. Predictions derived from the spectrum conversion (NIR to MIR) task did not match the performance of the original MIR spectra but were similar or superior to predictive performance of NIR-only models, suggesting the unified spectral latent space can effectively leverage the larger and more diverse MIR dataset for prediction of soil properties not well represented in current NIR libraries.

54 ENVIRONMENTAL SCIENCES↗

Predicting the effect of angular momentum on the dissociation dynamics of highly rotationally excited radical intermediates

We present a model which accurately predicts the net speed distributions of products resulting from the unimolecular decomposition of rotationally excited radicals. The radicals are produced photolytically from a halogenated precursor under collision-free conditions so they are not in a thermal distribution of rotational states. The accuracy relies on the radical dissociating with negligible energetic barrier beyond the endoergicity. We test the model predictions using previous velocity map imaging and crossed laser-molecular beam scattering experiments that photolytically generated rotationally excited CD{sub 2}CD{sub 2}OH and C{sub 3}H{sub 6}OH radicals from brominated precursors; some of those radicals then undergo further dissociation to CD{sub 2}CD{sub 2} + OH and C{sub 3}H{sub 6} + OH, respectively. We model the rotational trajectories of these radicals, with high vibrational and rotational energy, first near their equilibrium geometry, and then by projecting each point during the rotation to the transition state (continuing the rotational dynamics at that geometry). This allows us to accurately predict the recoil velocity imparted in the subsequent dissociation of the radical by calculating the tangential velocities of the CD{sub 2}CD{sub 2}/C{sub 3}H{sub 6} and OH fragments at the transition state. The model also gives a prediction for the distribution of angles between the dissociation fragments’ velocity vectors and the initial radical’s velocity vector. These results are used to generate fits to the previously measured time-of-flight distributions of the dissociation fragments; the fits are excellent. The results demonstrate the importance of considering the precession of the angular velocity vector for a rotating radical. We also show that if the initial angular momentum of the rotating radical lies nearly parallel to a principal axis, the very narrow range of tangential velocities predicted by this model must be convoluted with a J = 0 recoil velocity distribution to achieve a good result. The model relies on measuring the kinetic energy release when the halogenated precursor is photodissociated via a repulsive excited state but does not include any adjustable parameters. Even when different conformers of the photolytic precursor are populated, weighting the prediction by a thermal conformer population gives an accurate prediction for the relative velocity vectors of the fragments from the highly rotationally excited radical intermediates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Distributed Magnetic Field and Temperature Monitoring for Superconducting Radio Frequency Cavities

The overall objective of the proposed Phase I program was to design, construct and demonstrate a fiber optic sensing system capable of providing temperature and magnetic field measurements with an enhanced spatial resolution that can be implemented over a large surface area (cryomodules) to survey superconducting radio frequency cavities and magnets. A magnetic field sensor capable of detecting fluxes on the order of 1 μT is required to detect the distribution of trapped flux on the cavity surface. A unique distributed magnetic field sensor was successfully designed and constructed to demonstrate the detection of magnetic fluxes less than 500 nT. The sensor leveraged the ultra-high sensitivity of Sentek’s picoDAS to measure the magnetostriction induced vibrations in a commercially available Metglas 2605 SC ribbon that was in physical contact with sensing fiber. Static magnetic fields were detected by applying an alternating current a copper wire proximate to the Metglas 2605SC ribbon to create an AC bias magnetic field. In an alternative approach, an AC bias magnetic field was applied to a special magnetic field sensing fiber with Metglas 2605SC cladding successfully detect a magnetic field flux of a 3 μT. Exhaustive testing was performed to characterize the dependency of sensor response on the direction of the applied magnetic field. Although the special sensing fiber based magnetic field sensor did not exhibit an observable dependence on the direction of the magnetic field, the Metglas 2605SC ribbon sensor exhibited a clear directional dependence. A wide variety of polymer materials were evaluated to enhance the temperature response of an FBG based sensor at cryogenic temperatures. The processing and performance challenges provided the motivation to develop a new simple cryogenic temperature sensor that uses a commercially available fiber optic splice protector. The EVA hot melt tube that becomes adhered to the optical fiber and the polyolefin outer tube that shrinks upon heating in the fusion splicer heater provide the high thermal expansion coefficient necessary to impart a significant strain on the FBG when exposed to cryogenic temperatures. The temperature sensitivity (Δ𝜆𝐵𝑟𝑎𝑔𝑔~ 62 𝑝𝑝𝑚/℃) of the FBG-based sensor was on par with the best reported to date. The simple design, use of readily available cost-effective materials, and well-established processing techniques lends this approach to the creation of hundreds to thousands of temperature sensors on one single optical fiber length. The inherently small form factor also allows for co-location with the distributed magnetic field sensor. In preparation for field testing of the prototype sensing system at the Jefferson Labs in potential Phase II program, several different cable designs were evaluated to package the sensors. The preliminary successful demonstration of fully functional sensing cables provides the foundation for subsequent development efforts to advance the Technology Readiness Level of the technology. The technical feasibility of the proposed approach was successfully demonstrated in this Phase I effort.

43 PARTICLE ACCELERATORS↗

Optimizing Deep Geothermal Drilling for Energy Sustainability in the Appalachian Basin

This study investigates the geological and geomechanical characteristics of the MIP 1S geothermal well in the Appalachian Basin to optimize drilling and address the wellbore stability issues encountered. Data from well logs, sidewall core analysis, and injection tests were used to derive elastic and rock strength properties, as well as stress and pore pressure profiles. A robust 1D-geomechanical model was developed and validated, correlating strongly with wellbore instability observations. This revealed significant wellbore breakout, widening the diameter from 12 ¼ inches to over 16 inches. Advanced technologies like Cerebro Force™ In-Bit Sensing were used to monitor drilling performance with high accuracy. This technology tracks critical metrics such as bit acceleration, vibration in the x, y, and z directions, Gyro RPM, stick-slip indicators, and bending on the bit. Cerebro Force™ readings identified hole drag caused by poor hole conditions, including friction between the drill string and wellbore walls and the presence of cuttings or debris. This led to higher torque and weight on bit (WOB) readings at the surface compared to downhole measurements, affecting drilling efficiency and wellbore stability. Optimal drilling parameters for future deep geothermal wells were determined based on these findings.

Environmental Sciences & Ecology↗

Study of Microphonic Effects on the C100 Cryomodule for High Energy Electron Beam Accelerators

The Continuous Electron Beam Accelerator Facility (CEBAF) at Thomas Jefferson National Laboratory (JLab) is a particle accelerator which can accelerate an electron beam to relativistic speeds and apply the beam onto target samples. The C100 superconducting radio frequency (SRF) cavity is the primary accelerating structure of the C100 cryomodule, one of the many cryomodules which compose the CEBAF linear accelerator. SRF cavities are particularly sensitive to internal and external vibrations that can result in a phenomenon called microphonics which degrade the operational stability of a cryomodule. The purpose of this thesis is to investigate the significance of mechanical disturbances on the electromagnetic resonant frequency of a C100 SRF cavity. Knowledge of the mechanical resonance of the cavities and cryomodule sheds light into how these disturbances are most easily realized as deformation which causes radio frequency (RF) detuning. Three studies were conducted: the development and hammer test calibration of a Finite Element Analysis (FEA) model of a C100 cavity, the development and hammer test calibration of an FEA model of a C100 cavity string, and the hammer test of the C100-10R cryomodule at the Cryomodule Test Facility (CMTF). The cavity FEA model was found to accurately predict two modes found in two real cavities in a simply supported configuration. The cavity string FEA model leveraged the calibrated cavity FEA model but was not found to accurately predict the modal behavior of a real cavity string. Even so, the modal behavior of the cavity string inside the C100-10R cryomodule was captured during a hammer test while it was partially assembled. Finally, the C100-10R cryomodule was placed in the CMTF to study RF detuning. The RF detuning spectra during hammer hits and background noise was captured. The results of the hammer testing indicate two strong peaks at low frequencies (9-10 Hz and 22-23 Hz). These two frequencies were found to be nearly coincident to four instances of mechanical resonance found during the hammer testing done on the partially-assembled C100-10R. Because of this, these two modes are believed to contribute to RF detuning of the cryomodule. This test event also included the testing of the effectiveness of a configuration of BNNT canisters designed to act as dampers. While these tests show promising results, the lurking variables render these tests somewhat inconclusive.

Hull, Caleb James↗

Nonlinear resonant ultrasound spectroscopy of stress corrosion cracking in stainless steel rods

Stainless steel containers are susceptible to stress corrosion cracking (SCC) under certain stress and corrosion conditions. Nonlinear ultrasonic techniques are very sensitive to the early presence of damage, more so than linear techniques. Nonlinear Resonant Ultrasound Spectroscopy (NRUS) is used here to measure a nonlinear shift in the resonance frequency due to a cumulative amount of SCC. Steel rods are immersed in a heated magnesium chloride solution and removed after different exposure times. NRUS measurements are conducted using the fundamental longitudinal mode of vibration. Rods exposed longer generally have a larger resonance frequency shift and are therefore more nonlinear. Thus NRUS might offer a means of detecting a cumulative SCC damage in a sample.