Search NASA⌕ Search

SEARCH · Search NASA

Results for “Well Test Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

HERO CarbonSAFE Phase 2 Project in the Columbia River Basalt Group

The Hermiston, Oregon Basalt CarbonSAFE Phase II project (HERO CarbonSAFE) seeks to accelerate the deployment of commercial carbon dioxide (CO2) storage projects in basaltic rocks. Basalt CO2 storage has several advantages to conventional saline storage reservoirs including 1. The potential for rapid mineralization of CO2, 2. Associated decreases in pressure and CO2 migration risks, 3. Reduced long-term monitoring requirements with respect to plume tracking, 4. Widespread geographic distribution and, 5. Large storage potential due to thickness, porosity, and CO2 interactions with basalt. And for locations such as the Pacific Northwest, Hawaii, Iceland, India and Japan, basalts may offer the only economically feasible option for local CO2 storage. However, there are limited field-scale assessments of CO2 storage in basalt, and current carbon capture utilization and storage (CCUS) permitting and regulatory frameworks were developed for conventional saline reservoirs. HERO CarbonSAFE is designed to address research gaps and uncertainties associated with basalt storage. Specifically, the project will assess the feasibility of CO2 injection in the deep layered basalts, long-term storage (mineralization), practical approaches for large-scale implementation (50+ million metric tons of CO2 over 30 years), lithology-specific risks, and the technoeconomic potential for CO2 storage in basalts. The HERO CarbonSAFE project will assess feasibility of developing a commercial-scale (50+ million metric tons of CO2) geological storage complex within the Columbia River Basalt Group (CRBG), a layered continental flood basalt complex that underlies Calpine’s natural gas-fired Hermiston Power Project (HPP) in Hermiston, OR (Figure 1). Under this 2-year CarbonSAFE Phase II project, the HERO team will conduct a data acquisition campaign that includes drilling a stratigraphic well to a total depth of ~1,500 m into the thick layered basalts proximal to HPP. A comprehensive well logging and hydrologic testing program will be augmented with new core collected from flow zones and sealing units, and comprehensive laboratory testing to help refine the kinetic rates of mineralization. The newly acquired information will be integrated with existing data from regional wells to correlate basalt injection zone properties to develop storage hub/commercial-scale models. Using these models, the project team will evaluate injection scenarios to define the technical and economic potential for storing a minimum of 50 million metric tons of CO2 over a 30-year period, along with a robust sensitivity analysis on key parameters governing reservoir viability for sustainable injection over a commercial project lifetime. Specific technical objectives of HERO are: (1) assessing the reservoir response of a series of stacked layered reservoir flowtop sequences occurring in this area of the CRBG to commercial-scale injection volumes; (2) extending prior efforts by the project team to characterize the deep layered basalts encountered in regional studies, to leverage prior investments by U.S. Department of Energy’s (DOE) Carbon Storage program; (3) leveraging DOE’s mineralization characterization efforts to advance model parametrization for commercial scale injection of CO2 in basalts; (4) conducting risk assessments associated with scaling up to commercial storage hub injection goals, while validating DOE’s National Risk Assessment Partnership (NRAP) tools, to identify potential constraints that would prevent the CRBG from serving as a commercial-scale storage complex; (5) developing mitigation plans to address identified risks; (6) developing a commercial-scale injection and monitoring, verification and accounting (MVA) strategy; (7) utilizing computational models to define and minimize, if possible, the Area of Review (AoR) under Class VI regulations; and (8) developing a robust CO2 management strategy for CRBG that also considers a regional source/sink approach that is responsive to stakeholder needs and industrial demand. Specific institutional objectives are: (1) identifying and developing plans to mitigate the nontechnical challenges associated with the build-out of a commercial-scale storage complex within the CRBG with integrated CO2 sources; (2) implementing the community outreach plan; (3) conducting regulatory research, including a survey of issues related to pore space ownership, MVA and long-term assurance of mineralization-based storage, to support an eventual application for a UIC Class VI permit; (4) advancing the project’s plan for CO2 liability management; and (5) continuing to refine and update the project’s economic model. The final objective is the preparation of a comprehensive Site Characterization Plan that draws upon the technical and institutional feasibility assessments to prepare the project for future commercialization efforts.

58 GEOSCIENCES↗

Space Launch System Booster Separation Supersonic Powered Testing with Surface and Off-Body Measurements

A wind tunnel test was run in the NASA Langley Unitary Plan Wind Tunnel simulating the separation of the two solid rocket boosters (SRB) from the core stage of the NASA Space Launch System (SLS). The test was run on a 0.9% scale model of the SLS Block 1B Cargo (27005) configuration and the SLS Block 1B Crew (28005) configuration at a Mach of 4.0. High pressure air was used to simulate plumes from the booster separation motors located at the nose and aft skirt of the two boosters. Force and moment data were taken on both SRBs and on the core stage. Schlieren still photos and video were recorded throughout testing. A set of points were acquired using Cross-correlation Doppler Global Velocimetry (CCDGV) readings to get 3 component velocity measurements between the core and the left-hand SRB. The CCDGV laser was utilized to record flow visualization in the same location, between the core and the left-hand SRB. Pressure Sensitive Paint data were taken on a separate set of runs. Computational Fluid Dynamics (CFD) runs were computed on a subset of the wind tunnel data points for comparison. A combination of the force/moment, CCDGV and Pressure Sensitive Paint (PSP) data (as well as schlieren images) at the CFD-specified test conditions will be used te the CFD simulations that will be used to build an SLS booster separation database flight conditions.

Winski, Courtney S.↗

Measurement of inclusive jet and dijet production in pp collisions at root s=7 TeV using the ATLAS detector

Inclusive jet and dijet cross sections have been measured in proton-proton collisions at a center-of-mass energy of 7 TeV using the ATLAS detector at the Large Hadron Collider. The cross sections were measured using jets clustered with the anti-k{sub t} algorithm with parameters R = 0.4 and R = 0.6. These measurements are based on the 2010 data sample, consisting of a total integrated luminosity of 37 pb{sup -1}. Inclusive jet double-differential cross sections are presented as a function of jet transverse momentum, in bins of jet rapidity. Dijet double-differential cross sections are studied as a function of the dijet invariant mass, in bins of half the rapidity separation of the two leading jets. The measurements are performed in the jet rapidity range |y| < 4.4, covering jet transverse momenta from 20 GeV to 1.5 TeV and dijet invariant masses from 70 GeV to 5 TeV. The data are compared to expectations based on next-to-leading-order QCD calculations corrected for nonperturbative effects, as well as to next-to-leading-order Monte Carlo predictions. In addition to a test of the theory in a new kinematic regime, the data also provide sensitivity to parton distribution functions in a region where they are currently not well-constrained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Viscosity measurements and empirical predictions for coal slags

Slag viscosity in slagging coal gasifier is an important factor affecting the gasification regime and operating cost. Most of the empirical viscosity models of coal slags that are available in the literature are applicable to only limited ranges of temperature and composition. To develop a reliable slag viscosity model, additional data are needed. Slag viscosity was measured under air or reducing atmosphere (calculated pO2~1.2 10-12 atm at 1400°C) at temperatures in the range of 1150-1550°C on 63 statistically designed slags, including 5 actual coal slag compositions and 4 validation slag compositions. The Arrhenius equation, with Arrhenius coefficients A = constant and B expressed as linear function of mass fractions of nine major components was used to fit the viscosity/temperature data. This Arrhenius relationship represents the viscosity–temperature relationship of tested slags reasonably well, = 0.981 (reducing atmosphere) and = 0.974 (air atmosphere). The validation of the model with four randomly selected slags (two from the SciGlass database and two from experimental design) indicated an accurately measured viscosity-temperature data and a fairly good predictive performance of slag viscosity models over designed compositions. The capability of the developed model to predict the viscosity of coal slags under reducing atmosphere was found to be a superior to a number of the most commonly used empirical models in the literature that are based on simplified oxide melts and British or Australian coal ash slags.

01 COAL, LIGNITE, AND PEAT↗

Developing scheduling benchmark tests for the Space Network

A set of benchmark tests were developed to analyze and measure Space Network scheduling characteristics and to assess the potential benefits of a proposed flexible scheduling concept. This paper discusses the role of the benchmark tests in evaluating alternative flexible scheduling approaches and defines a set of performance measurements. The paper describes the rationale for the benchmark tests as well as the benchmark components, which include models of the Tracking and Data Relay Satellite (TDRS), mission spacecraft, their orbital data, and flexible requests for communication services. Parameters which vary in the tests address the degree of request flexibility, the request resource load, and the number of events to schedule. Test results are evaluated based on time to process and schedule quality. Preliminary results and lessons learned are addressed.

Moe, Karen L.↗

Parameter Calibration for Johnson Cook and Preston-Tonks-Wallace Material Strength Models with Uncertainty Quantification

In this study we perform a Bayesian calibration of the parameters in the Johnson Cook (JC) material strength model, with uncertainty, using experiments with for a range of low and medium strain rates. For the parameter calibration, we used a variational Bayesian approach with experimental data from Hopkinson bar and quasi-static tests done on Oxygen Free High Conductivity (OFHC) copper. The estimated parameter values matched well with experimental data for a modest range of strain rates and temperatures. Through this method, we also recovered uncertainty and correlation information for the estimated parameter values. We also compared our results to a calibration of parameters in the Preston-Tonks-Wallace (PTW) material strength model, using the same variational Bayesian method. The parameters estimated for both models provided good agreement with the experimental data.

36 MATERIALS SCIENCE↗

Subsonic stability and control flight test results of the Space Shuttle /tail cone off/

The subsonic stability and control testing of the Space Shuttle Orbiter in its two test flights in the tailcone-off configuration is discussed, and test results are presented. Flight test maneuvers were designed to maximize the quality and quantity of stability and control data in the minimal time allotted using the Space Shuttle Functional Simulator and the Modified Maximum Likelihood Estimator (MMLE) programs, and coefficients were determined from standard sensor data sets using the MMLE, despite problems encountered in timing due to the different measurement systems used. Results are included for lateral directional and longitudinal maneuvers as well as the Space Shuttle aerodynamic data base obtained using the results of wind tunnel tests. The flight test data are found to permit greater confidence in the data base since the differences found are well within control system capability. It is suggested that the areas of major differences, including lateral directional data with open speedbrake, roll due to rudder and normal force due to elevon, be investigated in any further subsonic flight testing. Improvements in sensor data and data handling techniques for future orbital test flights are indicated.

Cooke, D. R.↗

An Initial Assessment of the Surface Reference Technique Applied to Data from the Dual-Frequency Precipitation Radar (DPR) on the GPM Satellite

It has long been recognized that path-integrated attenuation (PIA) can be used to improve precipitation estimates from high-frequency weather radar data. One approach that provides an estimate of this quantity from airborne or spaceborne radar data is the surface reference technique (SRT), which uses measurements of the surface cross section in the presence and absence of precipitation. Measurements from the dual-frequency precipitation radar (DPR) on the Global Precipitation Measurement (GPM) satellite afford the first opportunity to test the method for spaceborne radar data at Ka band as well as for the Ku-band-Ka-band combination. The study begins by reviewing the basis of the single- and dual-frequency SRT. As the performance of the method is closely tied to the behavior of the normalized radar cross section (NRCS or sigma(0)) of the surface, the statistics of sigma(0) derived from DPR measurements are given as a function of incidence angle and frequency for ocean and land backgrounds over a 1-month period. Several independent estimates of the PIA, formed by means of different surface reference datasets, can be used to test the consistency of the method since, in the absence of error, the estimates should be identical. Along with theoretical considerations, the comparisons provide an initial assessment of the performance of the single- and dual-frequency SRT for the DPR. The study finds that the dual-frequency SRT can provide improvement in the accuracy of path attenuation estimates relative to the single-frequency method, particularly at Ku band.

space-borne weather radars↗

Development and testing of neutron cross-section covariance data for Scale 6.2 - 14604

Neutron cross-section covariance data are essential for many sensitivity/uncertainty and uncertainty quantification assessments performed both within the TSUNAMI suite and more broadly throughout the SCALE code system. The release of ENDF/B-VII.1 included a more complete set of neutron cross-section covariance data: these data form the basis for a new cross-section covariance library to be released in SCALE 6.2. A range of testing is conducted to investigate the properties of these covariance data and ensure that the data are reasonable. These tests include examination of the uncertainty in critical experiment benchmark model k{sub eff} values due to nuclear data uncertainties, as well as similarity assessments of irradiated pressurized water reactor (PWR) and boiling water reactor (BWR) fuel with suites of critical experiments. The contents of the new covariance library, the testing performed, and the behavior of the new covariance data are described in this paper. The neutron cross-section covariances can be combined with a sensitivity data file generated using the TSUNAMI suite of codes within SCALE to determine the uncertainty in system k{sub eff} caused by nuclear data uncertainties. The Verified, Archived Library of Inputs and Data (VALID) maintained at Oak Ridge National Laboratory (ORNL) contains over 400 critical experiment benchmark models, and sensitivity data are generated for each of these models. The nuclear data uncertainty in k{sub eff} is generated for each experiment, and the resulting uncertainties are tabulated and compared to the differences in measured and calculated results. The magnitude of the uncertainty for categories of nuclides (such as actinides, fission products, and structural materials) is calculated for irradiated PWR and BWR fuel to quantify the effect of covariance library changes between the SCALE 6.1 and 6.2 libraries. One of the primary applications of sensitivity/uncertainty methods within SCALE is the assessment of similarities between benchmark experiments and safety applications. This is described by a ck value for each experiment with each application. Several studies have analyzed typical ck values for a range of critical experiments compared with hypothetical irradiated fuel applications. The ck value is sensitive to the cross-section covariance data because the contribution of each nuclide is influenced by its uncertainty; large uncertainties indicate more likely bias sources and are thus given more weight. Changes in ck values resulting from different covariance data can be used to examine and assess underlying data changes. These comparisons are performed for PWR and BWR fuel in storage and transportation systems. (authors)

42 ENGINEERING↗

Mechanical testing of large thallium doped sodium iodide single crystals

The findings of mechanical tests performed on five thallium-doped sodium iodide NaI(Tl) crystals are presented. These crystals are all in the shape of circular flat plates, 20.0 in. in diameter an d0.5 in. thick. The test setup, testing procedure, and the test data are presented. Large crystals exhibit a high degree of material plasticity, as well as a much higher strength than previously anticipated, on the order of 500 psi. Also revealed from the testing is the fact that crystal with a large number of grain boundaries developed less plasticity, and therefore less permanent deformation, than those with fewer grain boundaries.

Lee, H. M.↗

Interferometer for Testing in Vibration Environments

Temporal phase shifting interferometers require a stable environment during the data acquisition, so that well controlled phase steps can be introduced between successively acquired interferograms. In contrast, single-frame interferometers need to acquire only one interferogram to provide a phase map with very good precision at high spatial resolution. Thus these interferometers are well suited for the interferometric testing of large optics with long radius of curvature for which vibration isolation is difficult, eg. testing astronomical telescope mirrors in a test tower, or testing space optics inside a cryogenic vacuum chamber. This paper describes the Instantaneous Phase Interferometer (IPI) by ADE Phase Shift, together with measurement results at NASA. The IPI consists of a polarization Twyman-Green interferometer operating at 632.8 nm, with single-frame data acquisition based on a spatial carrier technique. The spatial carrier fringes are generated by introducing large amount of tilt between the test beam and the reference beam. The phase information of the optical surface under test is encoded in the straightness of the interference fringes, which can be detected in a single frame with spatial sampling of 1000 x 1000 pixels. Measurements taken at the NASA Marshall Space Flight Cater in support of the characterization of developmental optics for the Next Generation Space Telescope are presented. Such tests consist of a mirror placed inside a cryogenic vacuum chamber, with the IPI placed outside the test chamber without any additional vibration isolation.

Eng, Ron↗

WE-H-207B-00: MRgRT

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗

WE-H-207B-01: Commissioning and QC

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗

WE-H-207B-02: MR-Driven RT Planning

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗

WE-H-207B-03: MRI Guidance in the Radiation Therapy Clinic: Site-Specific Discussions

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗

WE-H-207B-04: Strategies for Adaptive RT

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗

Incorporation of Mean Stress Effects into the Micromechanical Analysis of the High Strain Rate Response of Polymer Matrix Composites

The results presented here are part of an ongoing research program, to develop strain rate dependent deformation and failure models for the analysis of polymer matrix composites subject to high strain rate impact loads. A micromechanics approach is employed in this work, in which state variable constitutive equations originally developed for metals have been modified to model the deformation of the polymer matrix, and a strength of materials based micromechanics method is used to predict the effective response of the composite. In the analysis of the inelastic deformation of the polymer matrix, the definitions of the effective stress and effective inelastic strain have been modified in order to account for the effect of hydrostatic stresses, which are significant in polymers. Two representative polymers, a toughened epoxy and a brittle epoxy, are characterized through the use of data from tensile and shear tests across a variety of strain rates. Results computed by using the developed constitutive equations correlate well with data generated via experiments. The procedure used to incorporate the constitutive equations within a micromechanics method is presented, and sample calculations of the deformation response of a composite for various fiber orientations and strain rates are discussed.

Goldberg, Robert K.↗

OSCEF: The Open-Source CIM-EARTH Framework User Manual for Version 1.0

Computable general equilibrium (CGE) models are used when studying the impacts of economic activity on climate change and vice versa. These models typically include many countries, each endowed with different amounts of labor and natural resources; the commodities produced by those countries; and international trade and transportation of the commodities among the countries. These models are extended to account for the greenhouse gases emitted from burning fossil fuels. The Open-Source CIM-EARTH Framework (OSCEF) is an open-source framework for formulating large-scale CGE models based on the CIM-EARTH architecture. OSCEF Version 1.0 includes basic processing of social accounting matrices (SAMs), which contain critical input data for CGE models. Section 2 provides a quick installation guide OSCEF and the third-party libraries, as well as execution of the OSCEF test suite and use cases. Section 3 describes the SAM data format and Section 4 highlights the design and usage of a few key application programming interfaces (APIs) in OSCEF.

Choi, Sou-Cheng T.↗