Search NASA⌕ Search

SEARCH · Search NASA

Results for “application”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Building a Fault Tolerant MPI Application: A Ring Communication Example

Process failure is projected to become a normal event for many long running and scalable High Performance Computing (HPC) applications. As such many application developers are investigating Algorithm Based Fault Tolerance (ABFT) techniques to improve the efficiency of application recovery beyond what existing checkpoint/restart techniques alone can provide. Unfortunately for these application developers the libraries that their applications depend upon, like Message Passing Interface (MPI), do not have standardized fault tolerance semantics. This paper introduces the reader to a set of run-through stabilization semantics being developed by the MPI Forum's Fault Tolerance Working Group to support ABFT. Using a well-known ring communication program as the running example, this paper illustrates to application developers new to ABFT some of the issues that arise when designing a fault tolerant application. The ring program allows the paper to focus on the communication-level issues rather than the data preservation mechanisms covered by existing literature. This paper highlights a common set of issues that application developers must address in their design including program control management, duplicate message detection, termination detection, and testing. The discussion provides application developers new to ABFT with an introduction to both new interfaces becoming available, and a range of design issues that they will likely need to address regardless of their research domain.

99 GENERAL AND MISCELLANEOUS↗

Tracking Radioactive Isotopes in HVAC and Application for Hot Cell Analyses - 20155

In recent years, the surge in the number of isotope production facilities under design has increased the need to analyze isotope migration in facility Heating, Ventilation, and Air Conditioning (HVAC) during normal operations and accident scenarios. These facilities are used to produce isotopes for medical, security, and industrial applications and as such are subject to license and regulatory requirements 10CFR20, 10CFR30, 10CFR50, and 10CFR70. GOTHIC, a general-purpose thermal-hydraulics software package, includes the ability to model isotopic tracers, radioactive decay and isotope migration as well as HEPA and charcoal filters for isotope retention. A GOTHIC model was developed by Zachry Nuclear Engineering (ZNE) to examine the effect of negative room pressure, HEPA filtration, and HVAC fluctuations on radiation areas, hot cells and gloveboxes. Radioactive tracers were used to simulate the concentration of spills within contaminated areas, track the migration of isotopes of interest, and determine the isotopic retention and buildup on facility HEPA filters. A variety of isotopes with concern to dose (e.g., Kr-85, Sr-90, I-131, etc.), including their decay and progeny, are included in the analysis. Negative pressures are maintained in the regions of interest by a representative central HVAC system equipped with a volumetric fan that exhausts to the environment after a series of isolation valves and HEPA filters. GOTHIC is an industry trusted tool for providing engineering solutions for a variety of applications, including fission product tracking, aerosol and particulate transport and ventilation assessments. The software provides an integrated analysis environment that includes a graphical user interface (GUI) for constructing analysis models, a numerical solver that includes parallel processing capabilities and a post-processor for evaluating simulation results. It solves the conservation equations for mass, momentum and energy for multicomponent, multi-phase flow in lumped parameter and multi-dimensional geometries (1, 2, or full 3D), including the effects of turbulence, diffusion and buoyancy. It has been developed and maintained under a Quality Assurance program in compliance with the requirements of 10CFR50 Appendix B and applicable portions of ASME NQA-1 since 1995. GOTHIC has been used for assessing both forced and natural convection conditions for a wide range of applications, including: - Tracking concentration of hazardous gases and chemicals for habitability and safety assessments - Determining ventilation and filtration requirements and optimizing location and arrangement of these systems - Room heat-up, including diverse and Flexible coping strategies for Extended Loss of AC Power (FLEX/ELAP) - Equipment Qualification (EQ) A distinctive feature of GOTHIC is the ability to track many different fields/substances in a simulation, including user defined tracer elements, in the liquid, vapor and droplet fields as well as surfaces and filters. This capability allows GOTHIC to model fission product transport and release or the removal of particulates or harmful toxins from exhaust gases using a spray scrubber or other types of filtration systems. GOTHIC also includes models for engineered equipment, such as fans, filters, charcoal filters, dryers/demisters, dampers, etc. The aerosols and other filtered material are removed or accumulated in these components. The range of aerosol and radiological applications that GOTHIC has been used for includes: - Source Term: Primary Coolant (Equilibrium) Activity; Non-Water Coolant Source/Leakage. - Conditions for Iodine Re-evolution: Sump/Suppression Pool Conditions and pH; - RWST Conditions and pH. - Isotope Removal Mechanisms: Containment Sprayed and Unsprayed Region Mixing; Charcoal Filter Heating due to Iodine decay. - Radionuclide Transport and Decay: Post-LOCA Release in containment; Transport between connected Compartments and vent systems; Groundwater transport of radionuclides. - Non-Newtonian Fluid modeling for sludge, waste tanks, etc. ADAMS ML071581053 (titled 'Best Practice Guidelines for the use of CFD in Nuclear Reactor Safety Applications') poses guidelines for applying single phase CFD codes in nuclear reactor safety problems and GOTHIC is listed as a 'tool for 3D flows' and 'dispersal and deposition of radionuclides.' The Nuclear Quality Assurance (NQA) pedigree of GOTHIC is an important aspect for applications in the nuclear industry. The fundamental tracer models (convective transport, molecular and turbulent diffusion, removal mechanisms, etc.) have been verified using analytical solutions and validated against applicable separate effects tests. Also, GOTHIC has been benchmarked to many integrated effects tests, including Phebus FP (Fission Product). GOTHIC gives good agreement for the buildup and decay of fission products in Phebus Test 3. The model developed by ZNE demonstrates GOTHIC's applicability and acceptability for use in analyzing the migration and retention of radioactive isotopes and their progeny in normal operation and accident scenario analyses for isotope production facilities, hot cells, and gloveboxes. The tracer activities calculated by GOTHIC can then be used in downstream radiation transport and shielding codes like RADTRAD-NAI{sup C}, MCNP{sup R}, and MicroShield{sup R} to determine on-site and of-site doses. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recent Progress on the Stochastic Objective Decision Aide (SODA) Application

Idaho State University, in collaboration with Idaho National Laboratory, is engaged in development of a simple to use software application that utilizes stochastic techniques for the calculation of radiation doses associated with hypothetical radioactive material releases. This work is being performed through a grant from the U.S. Department of Energy (DOE) Nuclear Safety Research and Development (NSR and D) Program. Initial progress on the application was reported previously. Recent additions to the application are reported here. The Stochastic Objective Decision Aide (SODA) provides an easy to use software application to help decision makers support their judgment about the need or lack of need for safety structures, systems, and components. SODA is not intended to replace traditional design basis accident dose calculation methodology, nor is it intended to replace existing software used to perform formal dose consequence calculations. Rather, SODA is intended to supplement information obtained from existing codes to give a decision maker more information about an accident scenario. SODA also provides a simple method to perform parametric or sensitivity studies on individual input parameters. Non-reactor nuclear facilities operated under the approval authority of the US DOE use unmitigated hazard evaluations to determine if potential radiological doses associated with design basis events challenge dose evaluation guidelines. Unmitigated events that sufficiently challenge dose evaluation guidelines merit the selection of safety structures, systems, or components (SSCs) to prevent or mitigate the hazard. Dose consequence calculations traditionally involve use of the 'five-factor' formula: ST = MAR.DR.ARF.RF.LPF where ST is the source term (Bq), MAR is the total available material-at-risk (Bq), DR is the damage ratio (no units), ARF is the airborne release fraction (no units), RF is the respirable fraction (no units), and LPF is the leak path factor (no units). Potential radiation doses are then calculated using: CED = χ/Q.BR.ST.DCF (2) where CED is the committed effective dose (Sv), χ/Q is the plume dispersion (s/m{sup 3}), BR is the breathing rate (m{sup 3}/s), ST is the source term (Bq), and DCF is the dose conversion factor (Sv/Bq). Conservative single value input parameters are typically used to represent ARF, RF, LPF and BR. The traditional methodology, while conservative, can lead to skewed conclusions in the balance between cost and risk reduction resulting in over engineered systems with greater design, construction and operating costs. Rather than using a bounding single point value for each parameter in the dose consequence calculation, SODA uses distributions for some or all of the parameters. Each input parameter distribution is stochastically sampled and the resulting dose consequence calculation is repeated many times to develop a dose consequence distribution. The resulting distribution provides more information for the decision maker to rely upon when determining the need for safety SSCs. The SODA application was developed using MATLAB and it incorporates the use of Monte Carlo techniques as well as a graphical user interface (GUI). The application includes user selection of the governing distribution for parameters such as the MAR, DR, ARF, RF, LPF,χ/Q, BR, and DCF. While MATLAB was used for the development work, the application is distributed as a self-contained executable program. Features of the application include pull down menus with available distributions for the various parameters. The user has the option to plot the input parameter distribution that results from the random sampling process. The resulting dose consequence distribution is automatically analyzed to determine its similarity to well know distributions. This was done using the Bayesian Information Criterion method. If the resulting distribution is sufficiently similar to a well-known distribution, the application provides information about the distributions such as the mean value and other parameters. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Continuous whole-system monitoring toward rapid understanding of production HPC applications and systems

A detailed understanding of HPC applications’ resource needs and their complex interactions with each other and HPC platform resources are critical to achieving scalability and performance. Such understanding has been difficult to achieve because typical application profiling tools do not capture the behaviors of codes under the potentially wide spectrum of actual production conditions and because typical monitoring tools do not capture system resource usage information with high enough fidelity to gain sufficient insight into application performance and demands. In this paper we present both system and application profiling results based on data obtained through synchronized system wide monitoring on a production HPC cluster at Sandia National Laboratories (SNL). We demonstrate analytic and visualization techniques that we are using to characterize application and system resource usage under production conditions for better understanding of application resource needs. Furthermore, our goals are to improve application performance (through understanding application-to-resource mapping and system throughput) and to ensure that future system capabilities match their intended workloads.

97 MATHEMATICS AND COMPUTING↗

A survey of software implementations used by application codes in the Exascale Computing Project

The US Department of Energy Office of Science and the National Nuclear Security Administration initiated the Exascale Computing Project (ECP) in 2016 to prepare mission-relevant applications and scientific software for the delivery of the exascale computers starting in 2023. The ECP currently supports 24 efforts directed at specific applications and six supporting co-design projects. These 24 application projects contain 62 application codes that are implemented in three high-level languages—C, C++, and Fortran—and use 22 combinations of graphical processing unit programming models. The most common implementation language is C++, which is used in 53 different application codes. The most common programming models across ECP applications are CUDA and Kokkos, which are employed in 15 and 14 applications, respectively. This article provides a survey of the programming languages and models used in the ECP applications codebase that will be used to achieve performance on the future exascale hardware platforms.

97 MATHEMATICS AND COMPUTING↗

PREPARING FOR EXASCALE: ORNL Leadership Computing Application Requirements and Strategy

In 2009 the Oak Ridge Leadership Computing Facility (OLCF), a U.S. Department of Energy (DOE) facility at the Oak Ridge National Laboratory (ORNL) National Center for Computational Sciences (NCCS), elicited petascale computational science requirements from leading computational scientists in the international science community. This effort targeted science teams whose projects received large computer allocation awards on OLCF systems. A clear finding of this process was that in order to reach their science goals over the next several years, multiple projects will require computational resources in excess of an order of magnitude more powerful than those currently available. Additionally, for the longer term, next-generation science will require computing platforms of exascale capability in order to reach DOE science objectives over the next decade. It is generally recognized that achieving exascale in the proposed time frame will require disruptive changes in computer hardware and software. Processor hardware will become necessarily heterogeneous and will include accelerator technologies. Software must undergo the concomitant changes needed to extract the available performance from this heterogeneous hardware. This disruption portends to be substantial, not unlike the change to the message passing paradigm in the computational science community over 20 years ago. Since technological disruptions take time to assimilate, we must aggressively embark on this course of change now, to insure that science applications and their underlying programming models are mature and ready when exascale computing arrives. This includes initiation of application readiness efforts to adapt existing codes to heterogeneous architectures, support of relevant software tools, and procurement of next-generation hardware testbeds for porting and testing codes. The 2009 OLCF requirements process identified numerous actions necessary to meet this challenge: (1) Hardware capabilities must be advanced on multiple fronts, including peak flops, node memory capacity, interconnect latency, interconnect bandwidth, and memory bandwidth. (2) Effective parallel programming interfaces must be developed to exploit the power of emerging hardware. (3) Science application teams must now begin to adapt and reformulate application codes to the new hardware and software, typified by hierarchical and disparate layers of compute, memory and concurrency. (4) Algorithm research must be realigned to exploit this hierarchy. (5) When possible, mathematical libraries must be used to encapsulate the required operations in an efficient and useful way. (6) Software tools must be developed to make the new hardware more usable. (7) Science application software must be improved to cope with the increasing complexity of computing systems. (8) Data management efforts must be readied for the larger quantities of data generated by larger, more accurate science models. Requirements elicitation, analysis, validation, and management comprise a difficult and inexact process, particularly in periods of technological change. Nonetheless, the OLCF requirements modeling process is becoming increasingly quantitative and actionable, as the process becomes more developed and mature, and the process this year has identified clear and concrete steps to be taken. This report discloses (1) the fundamental science case driving the need for the next generation of computer hardware, (2) application usage trends that illustrate the science need, (3) application performance characteristics that drive the need for increased hardware capabilities, (4) resource and process requirements that make the development and deployment of science applications on next-generation hardware successful, and (5) summary recommendations for the required next steps within the computer and computational science communities.

applications requirements↗

Application health monitoring for extreme-scale resiliency using cooperative fault management

Resiliency is and will be a critical factor in determining scientific productivity on current and exascale supercomputers, and beyond. Applications oblivious to and incapable of handling transient soft and hard errors could waste supercomputing resources or, worse, yield misleading scientific insights. In this work, we introduce a novel application-driven silent error detection and recovery strategy based on application health monitoring. Our methodology uses application output that follows known patterns, as indicators of an application's health and knowledge that violation of these patterns could be indication of faults. Information from system monitors that report hardware and software health status is used to corroborate faults. Collectively, this information is used by a fault coordinator agent to take preventive and corrective measures by applying computational steering to an application between checkpoints. This cooperative fault management system uses the Fault Tolerance Backplane as a communication channel. The benefits of this framework are demonstrated with two real application case studies, molecular dynamics, and quantum chemistry simulations, on scalable clusters with simulated memory and I/O corruptions. Lastly, the developed approach is general and can be easily applied to other applications.

97 MATHEMATICS AND COMPUTING↗

An extensible and lightweight architecture for adaptive server applications

Server applications augmented with behavioral adaptation logic can react to environmental changes, creating self-managing server applications with improved quality of service at runtime. However, developing adaptive server applications is challenging due to the complexity of the underlying server technologies and highly dynamic application environments. This paper presents an architecture framework, the Adaptive Server Framework (ASF), to facilitate the development of adaptive behavior for legacy server applications. ASF provides a clear separation between the implementation of adaptive behavior and the business logic of the server application. This means a server application can be extended with programmable adaptive features through the definition and implementation of control components defined in ASF. Furthermore, ASF is a lightweight architecture in that it incurs low CPU overhead and memory usage. We demonstrate the effectiveness of ASF through a case study, in which a server application dynamically determines the resolution and quality to scale an image based on the load of the server and network connection speed. The experimental evaluation demonstrates the erformance gains possible by adaptive behavior and the low overhead introduced by ASF.

97 MATHEMATICS AND COMPUTING↗

Application-Specific Fault Tolerance via Data Access Characterization

Recent trends in semiconductor technology and supercomputer design predict an increasing probability of faults during an application's execution. Designing an application that is resilient to system failures requires careful evaluation of the impact of various approaches on preserving key application state. In this paper, we present our experiences in an ongoing effort to make a large computational chemistry application fault tolerant. We construct the data access signatures of key application modules to evaluate alternative fault tolerance approaches. We present the instrumentation methodology, characterization of the application modules, and evaluation of fault tolerance techniques using the information collected. The application signatures developed capture application characteristics not traditionally revealed by performance tools. We believe these can be used in the design and evaluation of runtimes beyond fault tolerance.

99 GENERAL AND MISCELLANEOUS↗

System modeling for grid-interactive efficient building applications

Despite the abundance of research applications of system modeling in grid-interactive efficient buildings (GEBs), the transfer of those applications to real-world practices is still in its early stages. This is partially due to the lack of a summary on how system modeling should be established for a given application of GEBs. Here, we fill this gap by providing an extensive survey of the literature on system modeling for different GEBs that have been produced in the past decade. This survey involves over 300 relevant journal articles from the building community, the power system community, and the society of control. Specifically, we first identified key requirements of system modeling for GEBs based on various types of applications discussed in those publications. We then summarized the system modeling applications from those publications, in terms of their assumptions, modeling approach, and simulation. After that, we analyzed different assumptions made for various applications, the extent to which those modeling approaches satisfied the key requirements, and how those approaches can be scaled up for large-scale applications, which are quite common in GEBs. In addition, we gave insights on how to use system modeling for different applications in GEBs. At the end, we provided recommended directions for future studies to fully unleash the potentials of system modeling to support GEBs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dosimetric Comparison of Tandem and Ovoids vs. Tandem and Ring for Intracavitary Gynecologic Applications

We evaluated dosimetric differences in tandem and ovoid (TO) and tandem and ring (TR) gynecologic brachytherapy applicators. Seventeen patients with cervical cancer (Stages II-IV) receiving 3 high-dose-rate (HDR) brachytherapy applications (both TO and TR) were studied. Patients underwent computed tomography (CT) scans with contrast in bladder, and were prescribed 8 Gy to ICRU points A, with additional optimization goals of maintaining the pear-shaped dose distribution and minimizing bladder and rectum doses. Bladder and rectum point doses, mean, and maximum doses were calculated. Total treatment time and volumes treated to 95%, 85%, 50%, and 20% or the prescription dose were compared. There were no significant differences between TO and TR applicators in doses to prescription points or critical organs. However, there were significant differences (p < 0.001) between the applicators in treated volumes and total treatment time. The TO treated larger volumes over a longer time. Within each patient, when the applicators were compared, treated volumes were also found to be significantly different (p < 0.01, {chi}{sup 2}). Our results demonstrate that the 2 applicators, while delivering the prescribed dose to points A and keeping critical organ doses below tolerance, treat significantly different volumes. It is unclear if this difference is clinically meaningful. TO applicators may be treating surrounding healthy tissue unnecessarily, or TR applicators may be underdosing tumor tissue. Further investigation with appropriate imaging modalities is required for accurate delineation of target volumes. Clearly, the TO and TR are not identical, and should not be used interchangeably without further study.

61 RADIATION PROTECTION AND DOSIMETRY↗

Implementation of a multi-threaded framework for large-scale scientific applications

The CMS experiment has recently completed the development of a multi-threaded capable application framework. In this paper, we will discuss the design, implementation and application of this framework to production applications in CMS. For the 2015 LHC run, this functionality is particularly critical for both our online and offline production applications, which depend on faster turn-around times and a reduced memory footprint relative to before. These applications are complex codes, each including a large number of physics-driven algorithms. While the framework is capable of running a mix of thread-safe and 'legacy' modules, algorithms running in our production applications need to be thread-safe for optimal use of this multi-threaded framework at a large scale. Towards this end, we discuss the types of changes, which were necessary for our algorithms to achieve good performance of our multithreaded applications in a full-scale application. Lastly performance numbers for what has been achieved for the 2015 run are presented.

97 MATHEMATICS AND COMPUTING↗

ParaOpt: Automated Application Parameterization and Optimization for the Cloud

The variety of instance types available on cloud platforms offers enormous flexibility to match the requirements of applications with available resources. However, selecting the most suitable instance type and configuring an application to optimally execute on that instance type can be complicated and time-consuming. For example, application parallelism flags must match available cores and problem sizes must be tuned to match available memory. As the search space of application configurations can be enormous, we propose an automated approach, called ParaOpt, to automatically explore and tune application configurations on arbitrary cloud instances. ParaOpt supports arbitrary applications, enables use of custom optimization methods, and can be configured with different optimization targets such as runtime and cost. We evaluate ParaOpt by optimizing genomics, molecular dynamics, and machine learning applications with four types of optimizers. We show with as few as 15 parameterized executions of an application, representing between 1.2%-26.7% of the search space, that ParaOpt is able to identify the optimal configuration in 32.7% of experiments and a near-optimal configuration in 83.2% of cases. As a result of using near-optimal configurations, ParaOpt reduces overall execution time by up to 85.8% when compared with using the default configuration.

Wu, Chaofeng↗

Autotuning in High-Performance Computing Applications

Autotuning refers to the automatic generation of a search space of possible implementations of a computation that are evaluated through models and/or empirical measurement to identify the most desirable implementation. Autotuning has the potential to dramatically improve the performance portability of petascale and exascale applications. To date, autotuning has been used primarily in high-performance applications through tunable libraries or previously tuned application code that is integrated directly into the application. This paper draws on the authors' extensive experience applying autotuning to high-performance applications, describing both successes and future challenges. If autotuning is to be widely used in the HPC community, researchers must address the software engineering challenges, manage configuration overheads, and continue to demonstrate significant performance gains and portability across architectures. In particular, tools that configure the application must be integrated into the application build process so that tuning can be reapplied as the application and target architectures evolve.

97 MATHEMATICS AND COMPUTING↗

Understanding the Performance and Potential of Cloud Computing for Scientific Applications

In this paper, commercial clouds bring a great opportunity to the scientific computing area. Scientific applications usually require significant resources, however not all scientists have access to sufficient high-end computing systems, may of which can be found in the Top500 list. Cloud Computing has gained the attention of scientists as a competitive resource to run HPC applications at a potentially lower cost. But as a different infrastructure, it is unclear whether clouds are capable of running scientific applications with a reasonable performance per money spent. This work studies the performance of public clouds and places this performance in context to price. We evaluate the raw performance of different services of AWS cloud in terms of the basic resources, such as compute, memory, network and I/O. We also evaluate the performance of the scientific applications running in the cloud. This paper aims to assess the ability of the cloud to perform well, as well as to evaluate the cost of the cloud running scientific applications. We developed a full set of metrics and conducted a comprehensive performance evlauation over the Amazon cloud. We evaluated EC2, S3, EBS and DynamoDB among the many Amazon AWS services. We evaluated the memory sub-system performance with CacheBench, the network performance with iperf, processor and network performance with the HPL benchmark application, and shared storage with NFS and PVFS in addition to S3. We also evaluated a real scientific computing application through the Swift parallel scripting system at scale. Armed with both detailed benchmarks to gauge expected performance and a detailed monetary cost analysis, we expect this paper will be a recipe cookbook for scientists to help them decide where to deploy and run their scientific applications between public clouds, private clouds, or hybrid clouds.

97 MATHEMATICS AND COMPUTING↗

Potential use of P-32 ophthalmic applicator: Monte Carlo simulations for design and dosimetry

Postoperative {beta}-irradiation after pterygium excision has been considered a valuable therapeutic procedure to reduce the recurrence rate. Recently, it was reported that {beta}-irradiation also substantially reduced the risk of surgical failure after glaucoma surgery. Pure {beta}-irradiation using a {sup 90}Sr/Y applicator has been almost exclusively used for this purpose. As an alternative to {sup 90}Sr/Y {beta}-irradiation, we propose treatment with betas of a {sup 32}P source. While {sup 32}P has a lower maximum energy (1.71 MeV) than {sup 90}Sr/Y (2.27 MeV), it has an average energy comparable to that of {sup 90}Sr/Y. Furthermore, it can be produced easily in a nuclear reactor by neutron activation and is considered a less hazardous material. Monte Carlo simulations for the dosimetry of proposed {sup 32}P applicators were performed using the MCNP5 code. The structure and dimension of the {sup 32}P applicators were based on those of the {sup 90}Sr/Y applicators currently available, while medical plastic encapsulation and liquid source were chosen to enhance {beta}-dose to the surface of the conjunctiva. The {sup 32}P applicator showed that the surface dose distribution (up to 0.75 mm depth) is very similar to that of {sup 90}Sr/Y. However, beyond 0.75 mm depth, the {sup 32}P doses decrease with depths more rapidly than {sup 90}Sr/Y doses. In order to achieve the same surface dose rate, the required {sup 32}P activity is about three times that for a {sup 90}Sr/Y applicator. We conclude that the proposed {sup 32}P applicator can deliver therapeutic doses to the target lesion while sparing the lens better than the {sup 90}Sr/Y applicator. The {sup 32}P activity required to deliver therapeutic doses can be produced in a 30 MW reactor available at the Korea Atomic Energy Research Institute.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment planning of a skin-sparing conical breast brachytherapy applicator using conventional brachytherapy software

Purpose: AccuBoost is a noninvasive image-guided technique for the delivery of partial breast irradiation to the tumor bed and currently serves as an alternate to conventional electron beam boost. To irradiate the target volume while providing dose sparing to the skin, the round applicator design was augmented through the addition of an internally truncated conical shield and the reduction of the source to skin distance. Methods: Brachytherapy dose distributions for two types of conical applicators were simulated and estimated using Monte Carlo (MC) methods for radiation transport and a conventional treatment planning system (TPS). MC-derived and TPS-generated dose volume histograms (DVHs) and dose distribution data were compared for both the conical and round applicators for benchmarking purposes. Results: Agreement using the gamma-index test was {>=}99.95% for distance to agreement and dose accuracy criteria of 2 mm and 2%, respectively. After observing good agreement, TPS DVHs and dose distributions for the conical and round applicators were obtained and compared. Brachytherapy dose distributions generated using Pinnacle{sup 3} for ten CT data sets showed that the parallel-opposed beams of the conical applicators provided similar PTV coverage to the round applicators and reduced the maximum dose to skin, chest wall, and lung by up to 27%, 42%, and 43%, respectively. Conclusions: Brachytherapy dose distributions for the conical applicators have been generated using MC methods and entered into the Pinnacle{sup 3} TPS via the Tufts technique. Treatment planning metrics for the conical AccuBoost applicators were significantly improved in comparison to those for conventional electron beam breast boost.

60 APPLIED LIFE SCIENCES↗

HDR brachytherapy of rectal cancer using a novel grooved-shielding applicator design

Purpose: The aim of this work was to design a novel high-dose rate (HDR) ({sup 192}Ir) brachytherapy applicator for treatment of rectal carcinomas that uses tungsten shielding for possibly improved dosimetric results over commercial brachytherapy applicator(s).Methods: A set of 15 single-depth applicators and one dual-depth applicator were designed and simulated using Monte Carlo (MCNPX). All applicators simulated were high-density tungsten alloy cylinders, 16-mm in diameter, and 60-mm long, with longitudinal grooves within which an {sup 192}Ir source can be placed. The single-depth designs varied regarding the number and depth of these grooves, ranging from 8 to 16 and 1-mm to 3-mm, respectively. The dual-depth design had ten channels, each of which had two depths at which the source could be placed. Optimized treatment plans were generated for each design on data from 13 treated patients (36 fractions) with asymmetrical clinical target volumes (CTVs). All results were compared against the clinically treated plans which used intracavitary mold applicator (ICMA), as well as a recently designed, highly automated, and collimated intensity modulation device named dynamic modulated brachytherapy (DMBT) device.Results: All applicator designs outperformed the ICMA in every calculated dosimetric criteria, except the total dwell times (∼30% increase). There were clear, but relative, tradeoffs regarding both the number of channels and the depth of each channel. Overall, the 12-channel, 1-mm depth, and 14-channel 2-mm depth designs had the best results of the simpler designs, sparing the healthy rectal tissues the most while achieving comparable CTV coverage with the dose heterogeneity index and lateral spill doses improving by over 10% and the contralateral healthy rectum dose dropping over 30% compared to ICMA. The ten-channel dual-depth design outperformed each single-depth design, yielding the best coverage and sparing.Conclusions: New grooved tungsten HDR-brachytherapy devices have been designed and simulated. The results of this work attest to the capability of these new, highly anisotropic, intelligently shielded applicators to limit dose to healthy tissues while maintaining a conformal prescription dose to the CTV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗