Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

X-ray spectrometer

An x-ray spectrometer includes: an x-ray plasma source that produces first x-rays; an x-ray optic in optical communication with the x-ray plasma source and that: receives the first x-rays from the x-ray plasma source; focuses the first x-rays to produce second x-rays; and communicates the second x-rays to a sample that produces product x-rays in response to receipt of the second x-rays and second light; and a microcalorimeter array detector in optical communication with the sample and that receives the product x-rays from the sample.

Ullom, Joel↗

AXEAP (ARGONNE X-RAY EMISSION PACKAGE)

Argonne X-ray Emission Package (AXEAP), a singular purpose software package for processing X-ray emission (XES) images collected with a 2-dimensional position sensitive pixel array detector, has been developed. AXEAP can rapidly convert XES image files into a spectral form by applying parallel computation and unsupervised machine learning to compute vast amount of image data. Special focus has been placed on designing user-friendly-interface for processing multiple edges, non-resonant and resonant x-ray emission image analysis, in order to make data processing quick and easy. AXEAP is free software and is written in MATLAB, armed with powerful libraries and toolboxes. The software runs on all common operating systems such as Linux, Window, and Mac.

SUN, CHENGJUN↗

Influence of dissolved salts and impurities on seawater on heat transfer and fluid flow through fuel channels and debris bed

This project aims to better understand this mechanism and its effect on heat transfer. Specifically, experimental research was conducted to investigate the long term coolability issues in scaled test setups. Advanced diagnostic and measurement techniques were investigated and incorporated into an annular test facility and a debris bed test facility. The diagnostic techniques investigated included: radioactively tagged salt solution, Frisch collar radiation detector array, neutron and x-ray imaging systems, and a Rayleigh backscatter-based fiber-optic temperature system. Models were checked against the in-situ experimental data and recommendations were made for modeling purposes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-contrast, convergent x-ray imaging with laser-Compton sources

Techniques are provided for the production of high-contrast, x-ray and/or gamma-ray radiographic images. The images have minimal contributions from object-dependent background radiation. The invention utilizes the low divergence, quasi-monoenergetic, x-ray or gamma-ray output from a laser-Compton source in combination with x-ray optical technologies to produce a converging x-ray or gamma-ray beam with which to produce a high-contrast, shadowgraph of a specific object. The object to be imaged is placed within the path of the converging beam between the x-ray optical assembly and the focus of the x-ray beam produced by that assembly. The beam is then passed through an optically thick pinhole located at the focus of the beam. Downstream of the pinhole, the inverted shadowgraph of the object is then recorded by an appropriate 2D detector array.

Barty, Christopher P. J.↗

Design and Contruction of a Longitudinally Polarized Solid Nuclear Target for CLAS12

A new polarized nuclear target has been developed, constructed, and deployed at Jefferson Laboratory in Newport News, VA for use with the upgraded 12 GeV CEBAF (Continuous Electron Beam Accelerator Facility) accelerator and the Hall B CLAS12 (12 GeV CEBAF Large Acceptance Spectrometer) detector array. This ?APOLLO? (Ammonia PO-Larized LOngitudinally) target is a longitudinally polarized, solid ammonia, nuclear target which employs DNP (Dynamic Nuclear Polarization) to induce a net polarization in samples of protons (NH3) and deuterons (ND3) cooled to 1 K via helium evaporation, held in a 5 T polarizing field supplied by the CLAS12 spectrometer, and irradiated with 140 GHz microwave radiation. It was utilized in the RGC (Run Group C) experiment suite through a collaboration of the JLab Target Group, Old Dominion University, Christopher Newport University, the University of Virginia, and the CLAS Collaboration. RGC comprised six experiments which measured multiple spin-dependent observables across a wide kinematic phase space for use in nucleon spin studies. The dimensional constraints necessary for the incorporation of APOLLO into CLAS12, as well as the considerations necessary to utilize the CLAS12 solenoid, introduced unique challenges to the target design. This document presents the innovative solutions developed for these challenges including a novel material transport system, superconducting magnetic correction coils, and an all new bespoke NMR (Nuclear Magnetic Resonance) system. In addition to a detailed description of the complete target system and an initial report of the RGC experimental run, it will also present a study of Quark-Hadron Duality in the g1 spin structure function based on Hall B EG1b data and pQCD fits from the JAM (Jefferson Lab Angular Momentum) Collaboration.

Lagerquist, Victoria Lagerquist↗

Development of the Low Granularity Pair Spectrometer counters in Hall D at JLab

The pair spectrometer in the photon beam line of Hall D at JLab is designed to monitor the stability of photon flux and the relative tagging efficiency of the photon tagger via a well known electron-positron pair production measurement. The pair spectrometer consists of a thin foil converter, a dipole magnet, and two identical left and right arm detector packages. Each detector package covers the electron or position energy from 3 GeV to 6.25 GeV. It consists of a front detector array for fine position resolution and rear scintillating hodoscopes to provide fast timing to form the pair production trigger. This presentation will focus on the construction and testing of the Low-Granularity Pair Spectrometer counters.

Dzbenski, Nathan↗

Neutron-induced capture-to-fission cross section ratio measured at LANSCE

Capture-to-fission cross section ratios are used as an alternative to absolute cross section measurements. This is due to the simplification on the calculations and the reduction of the uncertainties with respect to an absolute measurement of the cross section by eliminating experimental complications like self-absorption, beam/target overlap and non-uniformities. Different capture-to-fission reactions have been measured through the years at the Los Alamos Neutron Science Center (LANSCE) at Los Alamos National Laboratory (LANL) using the Detector for Advanced Neutron Capture Experiments (DANCE) combined with different fission detectors. Some of these are a Parallel Plate Avalanche Counter (PPAC) to detect fission fragments (FF), and the NEUtron detector array at DANCE (NEUANCE) to detect fission neutrons. As DANCE detects the γ-rays produced in capture and fission reactions, the fission instrument placed inside the DANCE cavity is used to tag the fission γ-rays for background identification and subtraction. Some examples of capture-to-fission ratio measurements performed with DANCE in the last years are the 233 U, 235 U and 239 Pu. The measurement technique, the different setups, and other potential applications of the instruments will be explained.

Nuclear Criticality Safety Program (NCSP)↗

Upper limit on the diffuse flux of UHE tau neutrinos from the Pierre Auger Observatory

The surface detector array of the Pierre Auger Observatory is sensitive to Earth-skimming tau-neutrinos {nu}{sub {tau}} that interact in the Earth's crust. Tau leptons from {tau}{sub {tau}} charged-current interactions can emerge and decay in the atmosphere to produce a nearly horizontal shower with a significant electromagnetic component. The data collected between 1 January 2004 and 31 August 2007 is used to place an upper limit on the diffuse flux of {nu}{sub {tau}} at EeV energies. Assuming an E{sub {nu}}{sup -2} differential energy spectrum the limit set at 90 % C.L. is E{sub {nu}}{sup 2} dN{sub {nu}{sub {tau}}}/dE{sub {nu}} < 1.3 x 10{sup -7} GeV cm{sup -2} s{sup -1} sr{sup -1} in the energy range 2 x 10{sup 17} eV < E{sub {nu}} < 2 x 10{sup 19} eV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectroscopy of neutron-rich palladium and cadmium isotopes near A=120

New high-spin levels have been identified in the nucleus {sup 120}Pd from analysis of the coincidence gamma rays observed in the {sup 238}U({alpha}, f{gamma}{gamma}{gamma}) reaction. Recoiling fragments were detected with the Rochester heavy-ion detector array, CHICO, in coincidence with gamma-rays using Gammasphere. An A=110-130 mass-gated {gamma} - {gamma} - {gamma} cube from this experiment was constructed and analyzed for coincident gamma-rays in several nuclei near A=120. New results for neutron-rich {sup 118}Pd and {sup 120}Pd have been obtained. The {sup 120}Pd level scheme was extended to spin of 10{sup +} by building on the new low-energy gamma rays identified in decay studies of {sup 120}Rh. The details of the {sup 118}Pd level scheme derived from this work are compared to previous work. The systematics of the yrast levels in even-even Pd and Cd isotopes are presented and the symmetry of energy levels around N = 68 is discussed. A new 10{sup +} level in {sup 124}Cd has been observed. The population intensity of even-even neutron-rich Cd isotopes is deduced, indicating that nuclides near {sup 120}Cd are preferentially populated following alpha-induced fission of {sup 238}U.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Binary Pseudo-random Grating Standard for Calibration of Surface Profilometers

We suggest and describe the use of a binary pseudo-random (BPR) grating as a standard test surface for measurement of the modulation transfer function (MTF) of interferometric microscopes. Knowledge of the MTF of a microscope is absolutely necessary to convert the measured height distribution of a surface undergoing metrology into an accurate power spectral density (PSD) distribution. For an'ideal' microscope with an MTF function independent of spatial frequency out to the Nyquist frequency of the detector array with zero response at higher spatial frequencies, a BPR grating would produce a flat 1D PSD spectrum, independent of spatial frequency. For a'real' instrument, the MTF is found as the square root of the ratio of the PSD spectrum measured with the BPR grating to the'ideal,' spatial frequency independent, PSD spectrum. We present the results from a measurement of the MTF of MicromapTM-570 interferometric microscope demonstrating a high efficiency for the calibration method.

, standards, surface roughness, interference micro↗

Results from the CDMS 5-Tower Operation

Astrophysical observations strongly suggest that non-luminous, nonbaryonic components, so called 'Dark Matter', may constitute most of the matter in the Universe. The Cryogenic Dark Matter Search (CDMS) experiment is designed to detect Dark Matter interaction events through nuclear recoils from elastic scattering. The detector is capable of reading out both phonon and ionization energy of an interaction in Ge or Si crystals. We present results from the CDMS five-tower detector arrays. The data were collected in the period between October 2006 and July 2007 (with an effective exposure of 121.3 kg-days). No WIMP signal was observed. The results, when combined with previous CDMS Soudan data, set a 90% confidence level upper bound on the WIMP-nucleon cross section of 4.6 x 10{sup -44} cm{sup 2} at 60 Gev/c{sup 2} WIMP mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scannerless loss modulated flash color range imaging

Scannerless loss modulated flash color range imaging methods and apparatus are disclosed for producing three dimensional (3D) images of a target within a scene. Apparatus and methods according to the present invention comprise a light source providing at least three wavelengths (passbands) of illumination that are each loss modulated, phase delayed and simultaneously directed to illuminate the target. Phase delayed light backscattered from the target is spectrally filtered, demodulated and imaged by a planar detector array. Images of the intensity distributions for the selected wavelengths are obtained under modulated and unmodulated (dc) illumination of the target, and the information contained in the images combined to produce a 3D image of the target.

47 OTHER INSTRUMENTATION↗

New results near {sup 100}Sn : observation of single-neutron states in {sup 101}Sn.

A search for in-beam {gamma}-ray transitions in {sup 101}Sn, which contains only one neutron outside the {sup 100}Sn core, using a novel approach was carried out at the Argonne Tandem-Linac System. {sup 101}Sn nuclei were produced using the {sup 46}Ti({sup 58}Ni, 3n){sup 101}Sn fusion-evaporation reaction. Beta-delayed protons with energies and decay times consistent with previous {sup 101}Sn decay studies were observed at the focal plane of the Fragment Mass Analyzer. In-beam {gamma} rays were detected in the Gammasphere Ge-detector array and were correlated with the {sup 101}Sn {beta}-delayed protons using the Recoil-Decay Tagging method. As a result, a {gamma}-ray transition between the single-neutron {nu}g{sub 7/2} and {nu}d{sub 5/2} states situated at the Fermi surface was identified. The measured {nu}g{sub 7/2}-{nu}d{sub 5/2} energy splitting was compared with predictions corresponding to various mean-field potentials and was used to calculate multi-neutron configurations in light Sn isotopes. Similar approach can be used to study core excitations in {sup 101}Sn and other exotic nuclei near {sup 100}Sn.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An analysis of 25Al energy levels observed in the 28Si(p,alpha)25Al reaction

The level structure of {sup 25}Al has been studied at the ORNL Holifield Radioactive Ion Beam Facility (HRIBF) by measuring the angular and energy distributions of alpha particles from the {sup 28}Si(p,{alpha}){sup 25}Al reaction. Proton beams ({approx}10 nA) at laboratory energies of 40- and 42-MeV were generated by the 25 MV tandem accelerator and bombarded a natural silicon target (50 {micro}g/cm{sup 2}). Alpha particles were detected and identified in the Silicon Detector Array (SIDAR) in the 'telescope' configuration [1]. Eighteen levels have been observed and spins for several have been constrained through a distorted-wave Born approximation (DWBA) analysis of the angular distributions.

43 PARTICLE ACCELERATORS↗

Development of a Fluxless Flip Chip Bonding Process for Optical Military Electronics

As military electronics tend to become lighter, smaller, thinner, and lower cost, the use of flip chip technology is becoming more common place to meet system requirements, yet survive environments. This paper explores the development of an optical flip chip application and details the selection/qualification of the substrate. The selected assembly consists of a procured 1x12 Vertical Cavity Surface Emitting Laser (VCSEL) die, having 80um diameter eutectic AuSn solder bumps at 250um pitch and flip chip bonded to a .006” thick 99.6% alumina substrate with .006” diameter thru holes and metallized with 500Å WTi, under minimum 2.0-3.0μm (80-120μ”) thin film deposited Au. An 8 run, 3 factor, 2 level Full Factorial Design of Experiments (DOE) was completed on procured detector arrays and procured ceramic substrates using the Suss Microtec FC150. The optimum settings for the peak temperature, peak time and final die z-height were selected using the ANOVA results and interaction plots. Additional studies were completed to qualify in-house produced substrates. An epoxy glob-top encapsulant was selected to dissipate stress on the flip chip solder joints and to enhance thermal shock performance.

42 ENGINEERING↗

Feeding of the 1 1/2- isomers in stable Ir and Au isotopes

Excited states were studied and absolute partial {gamma}-ray cross sections were measured using the ({eta}, {eta}'{gamma}) reaction in {sup 191}Ir, {sup 193}Ir and {sup 197}Au. A Compton-suppressed germanium-detector array (GEANIE) for {gamma}-ray spectroscopy and the broad-spectrum pulsed neutron source of the Los Alamos Neutron Science Center's WNR facility were used for the measurement. The energy of the incident neutrons was determined using the time-of-flight technique. Absolute partial {gamma}-ray cross sections were measured up to incident neutron energy of 20 MeV for several transitions feeding directly the 1 1/2- isomers and ground states in {sup 191}Ir, {sup 193}Ir and {sup 197}Au. The feeding of the 1 1/2- isomers, which originate from the odd proton occupying the h{sub 1 1/2} orbital, was found for the three targets to be very similar and increasing relative to the feeding of the corresponding ground state with increasing neutron energy up to E{sub n} {approx} 10 MeV. Above this neutron energy the opening of the (n, 2{sub n}) reaction channel strongly affects the population of the isomers and leads to a decrease of their relative population compared to the population of the ground states. The experimental results are compared with theoretical predictions from the GNASH reaction model calculation implementing a version of the spin distribution for the pre-equilibrium reaction piece with either a compound nucleus spin distribution (CN-GNASH) or a Feshbach-Kerman-Koonin (FKK-GNASH) quantum mechanical spin distribution. The effects of the spin cutoff parameter values on the population of states are examined. Evidence is presented that FKK-GNASH provides a description of the experimental data that mitigates the need for adjustment of the level density parameter to fit the data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scannerless loss modulated flash color range imaging

Scannerless loss modulated flash color range imaging methods and apparatus are disclosed for producing three dimensional (3D) images of a target within a scene. Apparatus and methods according to the present invention comprise a light source providing at least three wavelengths (passbands) of illumination that are each loss modulated, phase delayed and simultaneously directed to illuminate the target. Phase delayed light backscattered from the target is spectrally filtered, demodulated and imaged by a planar detector array. Images of the intensity distributions for the selected wavelengths are obtained under modulated and unmodulated (dc) illumination of the target, and the information contained in the images combined to produce a 3D image of the target.

47 OTHER INSTRUMENTATION↗

K-isomers near and away the line of stability.

Gammaray spectroscopy studies of deformed rareearth and transfermium nuclei provide valuable information on the phenomena associated with high-K isomers and on the seniority dependence of the major residual interactions in deformed nuclei. Most of the studies in the A{approx}180 region so far were focused on neutrondeficient nuclei that are accessible by heavyion fusion evaporation reactions. Recently deepinelastic and multinucleon transfer reactions, in conjunction with time correlated {gamma}-ray coincidence techniques and large g-ray detector arrays, have been shown to represent a powerful tool to study nuclei near the valley of stability, as well as to access neutronrich nuclei. In addition, the discovery and characterization of highK isomeric states in {sup 254}No and neighboring transfermium nuclei play an important role in better understanding the structure of the heaviest elements and in testing theoretical predictions of their stability. This presentation will review the status of recent Kisomer studies in various regions of the nuclear chart, including nuclei near the line of stability where the longestlived isomers are known to reside, protonand neutronrich nuclei away from the line of stability and transfermium nuclei at the limit of nuclear existence. Selected examples from g-ray spectroscopy measurements using Gammasphere spectrometer and Fragment Mass Analyzer at Argonne National Laboratory will be presented. Properties of two quasiparticle Kisomers in a number of eveneven Cm, Pu, Fm and No nuclei and predictions of their excitation energies, quantum numbers and associate configurations, including comparisons with available experimental data, will be also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗