Search NASA⌕ Search

SEARCH · Search NASA

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

SU-E-J-48: Development of An Abdominal Compression Device for Respiratory Correlated Radiation Therapy

Purpose: The aim of this study is to develop the abdominal compression device which could control pressure level according to the abdominal respiratory motion and evaluate its feasibility. Methods: In this study, we focused on developing the abdominal compression device which could control pressure level at any point of time so the developed device is possible to use a variety of purpose (gating technique or respiratory training system) while maintaining the merit of the existing commercial device. The compression device (air pad form) was designed to be able to compress the front and side of abdomen and the pressure level of the abdomen is controlled by air flow. Pressure level of abdomen (air flow) was determined using correlation data between external abdominal motion and respiratory volume signal measured by spirometer. In order to verify the feasibility of the device, it was necessary to confirm the correlation between the abdominal respiratory motion and respiratory volume signal and cooperation with respiratory training system also checked. Results: In the previous study, we could find that the correlation coefficient ratio between diaphragm and respiratory volume signal measured by spirometer was 0.95. In this study, we confirmed the correlation between the respiratory volume signal and the external abdominal motion measured by belt-transducer (correlation coefficient ratio was 0.92) and used the correlated respiratory volume data as an abdominal pressure level. It was possible to control the pressure level with negligible time delay and respiratory volume data based guiding waveforms could be properly inserted into the respiratory training system. Conclusion: Through this feasibility study, we confirmed the correlation between the respiratory volume signal and the external abdominal motion. Also initial assessment of the device and its compatibility with the respiratory training system were verified. Further study on application in respiratory gated therapy and respiratory training system will be investigated. This work was supported by Radiation Technology R and D program (No. 2013M2A2A7043498)and Basic Atomic Energy Research Institute (BAERI)(No. NRF-2009-0078390) through the National Research Foundation of Korea funded by the Ministry of Science, ICT and Future Planning.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-F-J-225: Histology Study of MR Guided Pulsed Focused Ultrasound On Treatment of Prostate Cancer in Vivo

Purpose: Our previous study demonstrated significant tumor growth delay in the mice treated with pulsed high intensity focused ultrasound (pHIFU). The purpose of this study is to understand the cell killing mechanisms of pHIFU. Methods: Prostate cancer cells (LNCaP), were grown orthotopically in 17 nude mice. Tumor-bearing mice were treated using pHIFU with an acoustic power of 25W, pulse width 100msec and 300 pulses in one sonication under MR guidance. Mutiple sonications were used to cover the whole tumor volume. The temperature (less than 40 degree centigrade in the focal spot) was monitored using MR thermometry. Animals were euthanized at pre-determined time points (n=2) after treatment: 0 hours; 6 hrs; 24 hrs; 48 hrs; 4 days and 7 days. Two tumorbearing mice were used as control. Three tumor-bearing mice were treated with radiation (RT, 2 Gy) using 6 MV photon beams. RT treated mice were euthanized at 0 hr, 6 hrs and 24 hrs. The tumors were processed for immunohistochemical (IHC) staining for PARP (a surrogate of apoptosis). A multispectral imaging analysis system was used to quantify the expression of PARP staining. Cell apoptosis was calculated based on the PARP expression level using the DAB analysis software. Results: Our data showed that PARP related apoptosis peaked at 48 hrs and 7 days in pHIFU treated mice, which is comparable to that for the RT group at 24 hrs. The preliminary results from this study were consistent with our previous study on tumor growth delay using pHIFU. Conclusion: Our results demonstrated that non-thermal pHIFU increased apoptotic tumor cell death through the PARP related pathway. MR guided pHIFU may have a great potential as a safe, noninvasive treatment modality for cancer therapy. This treatment modality may synergize with PARP inhibitors to achieve better therapeutic result.

60 APPLIED LIFE SCIENCES↗

Rapid Characterization of Vegetation Structure with a Microsoft Kinect Sensor

The importance of vegetation structure and biomass in controlling land-atmosphere exchange is widely recognized, but measurements of canopy structure are challenging, time consuming, and often rely on destructive methods. The Microsoft Kinect is an infrared sensor designed for video gaming that outputs synchronized color and depth images and that has the potential to allow rapid characterization of vegetation structure. We compared depth images from a Kinect sensor with manual measurements of plant structure and size for two species growing in a California grassland. The depth images agreed well with the horizontal and vertical measurements of plant size made manually. Similarly, the plant volumes calculated with a three-dimensional convex hulls approach was well related to plant biomass. The Kinect showed some limitations for ecological observation associated with a short measurement range and daytime light contamination. Nonetheless, the Kinect’s light weight, fast acquisition time, low power requirement, and cost make it a promising tool for rapid field surveys of canopy structure, especially in small-statured vegetation.

Microsoft Kinect↗

The German product quality control of the compacted metallic nuclear waste - 15311

The treatment and safe disposal of spent nuclear fuel is a key challenge of nuclear energy utilization and has to be accomplished regardless the future nuclear of electricity production or phase-out policies. Until June 2005 approx. 6662 tons of spent fuel from German nuclear power plants was sent to the La Hague (France) and Sellafield (UK) plants for reprocessing. An equivalent amount of nuclear waste compounds has contractually to be returned to Germany, which is currently in progress. The returnable waste streams comprise mainly highly-active vitrified waste containing a major part of fission products and actinides, and intermediate-active super-compacted metallic waste containing reprocessed fuel element's structural materials and some technological waste from the reprocessing process itself. Shearing and dissolution of spent fuel leaves scraps of fuel metal cladding, the end-pieces and spacers which are contaminated, activated and irradiating from their life in a reactor core. In fact, this metallic intermediate level radioactive waste makes up a bit more than half of the total volume of the reprocessed waste. At La Hague the metallic waste is super-compacted. Several, typically eight, compacted discs are stacked in a stainless steel container, named CSD-C as for 'Colis Standard de Dechets Compactes'. 4104 containers of such CSD-Cs in 152 transport/storages casks have to be returned to Germany. Each one of them has to be checked and quality certified for its conformity with German national product specifications and acceptance criteria by independent national product quality control inspectors (PKS). The residue package documentation has to be complete and the characterization methods have to be comprehensive. Due to the heterogeneity of metallic waste the characterization and control of its properties is very complex. The nuclear characterization is performed by means of non-destructive measurements, where only a few key nuclides are measured directly. In fact, the proper calculation of the whole nuclear inventory relies on numerous supplementary simulations. The measurement and calculation methodology is scrutinized by PKS in detail and key points are benchmarked with our own simulations for the sake of an independent nuclear inventory declaration check. With respect to the vast amount of documentation and parameters, which have to be checked and verified, PKS had to optimize their checking procedures. For this purpose dedicated proof tools have been developed that shall be applied for selected indicative cross-checks of the relevant parameters. This contribution is dedicated to the procedure of quality control by PKS and examples of actually performed computational verifications of declared nuclear inventory. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Growth of detector-grade CZT by Traveling Heater Method (THM): An advancement

In this present work we report the growth of Cd{sub 0.9}Zn{sub 0.1}Te doped with In by a modified THM technique. It has been demonstrated that by controlling the microscopically flat growth interface, the size distribution and concentration can be drastically reduced in the as-grown ingots. This results in as-grown detector-grade CZT by the THM technique. The three-dimensional size distribution and concentrations of Te inclusions/precipitations were studied. The size distributions of the Te precipitations/inclusions were observed to be below the 10-{micro}m range with the total concentration less than 10{sup 5} cm{sup -3}. The relatively low value of Te inclusions/precipitations results in excellent charge transport properties of our as-grown samples. The ({mu}{tau}){sub e} values for different as-grown samples varied between 6-20 x 10{sup -3} cm{sup 2}/V. The as-grown samples also showed fairly good detector response with resolution of {approx}1.5%, 2.7% and about 3.8% at 662 keV for quasi-hemispherical geometry for detector volumes of 0.18 cm{sup 3}, 1 cm{sup 3} and 4.2 cm{sup 3}, respectively.

99 GENERAL AND MISCELLANEOUS↗

Quality of Radiotherapy Reporting in Randomized Controlled Trials of Hodgkin's Lymphoma and Non-Hodgkin's Lymphoma: A Systematic Review

Purpose: Standards for the reporting of radiotherapy details in randomized controlled trials (RCTs) are lacking. Although radiotherapy (RT) is an important component of curative therapy for Hodgkin's lymphoma (HL) and non-Hodgkin's lymphoma (NHL), we postulated that RT reporting may be inadequate in Phase III HL and NHL trials. Methods and Materials: We searched PubMed and the Cochrane registry for reports of RCTs involving RT and either HL or NHL published between 1998 and 2007. We screened 133 titles and abstracts to identify relevant studies. We included a total of 61 reports. We assessed these reports for the presence of six quality measures: target volume, radiation dose, fractionation, radiation prescription, quality assurance (QA) process use, and adherence to QA (i.e., reporting of major or minor deviations). Results: Of 61 reports, 23 (38%) described the target volume. Of the 42 reports involving involved-field RT alone, only 8 (19%) adequately described the target volume. The radiation dose and fractionation was described in most reports (54 reports [89%] and 39 reports [64%], respectively). Thirteen reports specified the RT prescription point (21%). Only 12 reports (20%) described using a RT QA process, and 7 reports (11%) described adherence to the QA process. Conclusion: Reporting of RT in HL and NHL RCTs is deficient. Because the interpretation, replication, and application of RCT results depend on adequate description and QA of therapeutic interventions, consensus standards for RT reporting should be developed and integrated into the peer-review process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Positioning Accuracy of Four Different Immobilizations Using Cone-Beam CT in Radiotherapy of Non-Small-Cell Lung Cancer

Purpose: To evaluate the positioning accuracy of four different immobilizations by use of cone-beam computed tomography guidance for radiotherapy of non-small-cell lung cancer (NSCLC). Methods and Materials: Sixty-seven patients with NSCLC received conventional or stereotactic body radiotherapy. Of these, 30 were immobilized with a thermoplastic frame (TF), 16 with a thermoplastic frame and active breathing control (TF-ABC), 7 with a stereotactic body frame (SBF), and 14 with a stereotactic body frame and active breathing control (SBF-ABC). Cone-beam computed tomography scans at initial setup and after correction were registered to planning computed tomography. The positional errors in the left-to-right, superior-inferior, and anterior-posterior directions were analyzed. The planning target volume margins were calculated. Results: The precorrection systematic and random errors ranged from 1.9 to 4.2 mm for TF, 1.9 to 4.3 mm for SBF, 1.2 to 5.8 mm for TF-ABC, and 2.3 to 3.9 mm for SBF-ABC. The postcorrection systematic and random errors ranged from 0.3 to 1.9 mm for the four immobilizations. The planning target volume margins (conventional vs. stereotactic body radiotherapy) were 15.6 vs. 13.9 mm (TF), 14.9 vs. 14.8 mm (TF-ABC), 14.4 vs. 13.4 mm (SBF), and 9.9 vs. 9.4 mm (SBF-ABC) before correction and 7.3 vs. 6.9 mm (TF), 4.0 vs. 3.8 mm (TF-ABC), 7.5 vs. 7.1 mm (SBF), and 4.5 vs. 4.2 mm (SBF-ABC) after correction. Conclusions: The positioning accuracies of SBF and TF were similar. Active breathing control increased positioning error but reduced internal margin. Cone-beam computed tomography online correction improved the positioning accuracy of NSCLC patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proton Radiotherapy for Pediatric Central Nervous System Germ Cell Tumors: Early Clinical Outcomes

Purpose: To report early clinical outcomes for children with central nervous system (CNS) germ cell tumors treated with protons; to compare dose distributions for intensity-modulated photon radiotherapy (IMRT), three-dimensional conformal proton radiation (3D-CPT), and intensity-modulated proton therapy with pencil beam scanning (IMPT) for whole-ventricular irradiation with and without an involved-field boost. Methods and Materials: All children with CNS germinoma or nongerminomatous germ cell tumor who received treatment at the Massachusetts General Hospital between 1998 and 2007 were included in this study. The IMRT, 3D-CPT, and IMPT plans were generated and compared for a representative case. Results: Twenty-two patients were treated with 3D-CPT. At a median follow-up of 28 months, there were no CNS recurrences; 1 patient had a recurrence outside the CNS. Local control, progression-free survival, and overall survival rates were 100%, 95%, and 100%, respectively. Comparable tumor volume coverage was achieved with IMRT, 3D-CPT, and IMPT. Substantial normal tissue sparing was seen with any form of proton therapy as compared with IMRT. The use of IMPT may yield additional sparing of the brain and temporal lobes. Conclusions: Preliminary disease control with proton therapy compares favorably to the literature. Dosimetric comparisons demonstrate the advantage of proton radiation over IMRT for whole-ventricle radiation. Superior dose distributions were accomplished with fewer beam angles utilizing 3D-CPT and scanned protons. Intensity-modulated proton therapy with pencil beam scanning may improve dose distribution as compared with 3D-CPT for this treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Coarse-grained molecular dynamics integrated with convolutional neural network for comparing shapes of temperature sensitive bottlebrushes

Quantification of shape changes in nature-inspired soft material architectures of stimuli-sensitive polymers is critical for controlling their properties but is challenging due to their softness and flexibility. Here, we have computationally designed uniquely shaped bottlebrushes of a thermosensitive polymer, poly(N-isopropylacrylamide) (PNIPAM), by controlling the length of side chains along the backbone. Coarse-grained molecular dynamics simulations of solvated bottlebrushes were performed below and above the lower critical solution temperature of PNIPAM. Conventional analyses (free volume, asphericity, etc.) show that lengths of side chains and their immediate environments dictate the compactness and bending in these architectures. We further developed 100 unique convolutional neural network models that captured molecular-level features and generated a statistically significant quantification of the similarity between different shapes. Thus, our study provides insights into the shapes of complex architectures as well as a general method to analyze them. The shapes presented here may inspire the synthesis of new bottlebrushes.

36 MATERIALS SCIENCE↗

Ocelot: An Interactive, Efficient Distributed Compression-As-a-Service Platform With Optimized Data Compression Techniques

Large volumes of data generated by scientific simulations, genome sequencing, and other applications need to be moved among clusters for data collection/analysis. Data compression techniques have effectively reduced data storage and transfer costs. However, users' requirements on interactively controlling both data quality and compression ratios are non-trivial to fulfill. Here, we propose a novel Compression-as-a-Service (CaaS) platform called Ocelot with four important contributions: (1) It offers real-time visualization, interactive compression, and transfer of scientific datasets. (2) It incorporates new strategies for compressing diverse types of datasets more effectively than traditional methods. (3) It provides an effective method for estimating the compression ratio and execution time of compression tasks. (4) Experiments on multiple real-world datasets on geographically distributed computers show that Ocelot can significantly improve data transfer efficiency with a performance gain of more than 10x in computing clusters with relatively slow networks.

compression as a service (CaaS)↗

SU-F-R-44: Modeling Lung SBRT Tumor Response Using Bayesian Network Averaging

Purpose: The prediction of tumor control after a patient receives lung SBRT (stereotactic body radiation therapy) has proven to be challenging, due to the complex interactions between an individual’s biology and dose-volume metrics. Many of these variables have predictive power when combined, a feature that we exploit using a graph modeling approach based on Bayesian networks. This provides a probabilistic framework that allows for accurate and visually intuitive predictive modeling. The aim of this study is to uncover possible interactions between an individual patient’s characteristics and generate a robust model capable of predicting said patient’s treatment outcome. Methods: We investigated a cohort of 32 prospective patients from multiple institutions whom had received curative SBRT to the lung. The number of patients exhibiting tumor failure was observed to be 7 (event rate of 22%). The serum concentration of 5 biomarkers previously associated with NSCLC (non-small cell lung cancer) was measured pre-treatment. A total of 21 variables were analyzed including: dose-volume metrics with BED (biologically effective dose) correction and clinical variables. A Markov Chain Monte Carlo technique estimated the posterior probability distribution of the potential graphical structures. The probability of tumor failure was then estimated by averaging the top 100 graphs and applying Baye’s rule. Results: The optimal Bayesian model generated throughout this study incorporated the PTV volume, the serum concentration of the biomarker EGFR (epidermal growth factor receptor) and prescription BED. This predictive model recorded an area under the receiver operating characteristic curve of 0.94(1), providing better performance compared to competing methods in other literature. Conclusion: The use of biomarkers in conjunction with dose-volume metrics allows for the generation of a robust predictive model. The preliminary results of this report demonstrate that it is possible to accurately model the prognosis of an individual lung SBRT patient’s treatment.

60 APPLIED LIFE SCIENCES↗

Preliminary analysis of market potential for a hydropneumatic ground-level integrated diverse energy storage system

With the increasing share of renewable energy in the power grid, energy storage is considered a viable and effective solution to mitigate intermittency and improve power system stability. To quantify and estimate market potential for a recently developed Ground-Level Integrated Diverse Energy Storage (GLIDES) technology, the first operation model is developed for this hydropneumatic system and the bilinear pressure-volume terms are then linearized using the binary McCormick Relaxation method to improve solving efficiency. Based on up-to-date 5-min price data in four different real-time markets, several sets of experiments have been designed with three objective scenarios: maximize arbitrage, maximize arbitrage + reserve, maximize arbitrage + reserve + regulation. The experimental results show that the monetary value of GLIDES could be boosted by participation in ancillary markets and that regulation service might contribute more than half of the total revenue, even as high as 90% in PJM and ISONE markets. In addition, a case study for 1-day operation is used to illustrate the volume control of the GLIDES system.

25 ENERGY STORAGE↗

Coupling LaGrit unstructured mesh generation and model setup with TOUGH2 flow and transport: A case study

Furthermore, there are many applications in science and engineering modeling where an accurate representation of a complex model geometry in the form of a mesh is important. In applications of flow and transport in subsurface porous media, this is manifest in models that must capture complex geologic stratigraphy, structure (faults, folds, erosion, deposition) and infrastructure (tunnels, boreholes, excavations). Model setup, defined as the activities of geometry definition, mesh generation (creation, optimization, modification, refine, de-refine, smooth), assigning material properties, initial conditions and boundary conditions requires specialized software tools to automate and streamline the process. In addition, some model setup tools will provide more utility if they are designed to interface with and meet the needs of a particular flow and transport software suite. A control volume discretization that uses a two point flux approximation is for example most accurate when the underlying control volumes are 2D or 3D Voronoi tessellations. In this paper we will present the coupling of LaGriT, a mesh generation and model setup software suite and TOUGH2 to model subsurface flow problems and we show an example of how LaGriT can be used as a model setup tool for the generation of a Voronoi mesh for the simulation program TOUGH2. To generate the MESH file for TOUGH2 from the LaGriT output a standalone module Lagrit2Tough2 was developed, which is presented here and will be included in a future release of LaGriT. Here in this paper an alternative method to generate a Voronoi mesh for TOUGH2 with LaGriT is presented and thanks to the modular and command based structure of LaGriT this method is well suited to generating a mesh for complex models.

58 GEOSCIENCES↗

Validation of Heat Shock Protein 70 as a Tumor-Specific Biomarker for Monitoring the Outcome of Radiation Therapy in Tumor Mouse Models

Purpose: Tumor cells, in contrast to normal cells, frequently overexpress heat shock protein 70 (Hsp70) in the cytosol, present it on their cell surface, and actively release it. Therefore, soluble Hsp70 (sHsp70) was investigated as a potential tumor biomarker for monitoring the outcome of radiation therapy. Methods and Materials: Plasma from mice bearing membrane Hsp70 (mHsp70)-positive FaDu human squamous cell carcinoma of the head and neck and spontaneous pancreatic ductal adenocarcinoma (PDAC) was investigated. A cohort of mice with FaDu tumors (0.32 cm{sup 3}) was irradiated with 30 Gy, and plasma was collected 24 hours after irradiation, after the tumors had shrunk to 50% of their starting volume and after complete remission. sHsp70 levels in the plasma were quantified by enzyme-linked immunosorbent assay. Results: sHsp70 levels were significantly higher in the blood of tumor-bearing mice than that of control animals. A correlation between increasing sHsp70 plasma levels and tumor volume in the range of 0.01 cm{sup 3} to 0.66 cm{sup 3} was observed. Radiation-induced regression of the tumors was associated with significantly decreased sHsp70 levels, which returned to the level of control animals after complete remission. Conclusion: We propose sHsp70 as an innovative biomarker for detecting tumors and for monitoring the clinical outcome of radiation therapy in cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Review of heat transfer enhancement techniques for single phase flows

The thermal energy exchange between a flowing fluid and its confining channel is a ubiquitous process in modern society. To enhance the fluid-to-wall or wall-to-fluid heat transfer, several techniques have been developed to maximize the contact area between the fluid and the inner wall and/or disrupt the flow to enhance circulation or induce turbulence. Deployment of channels having features capable of enhancing heat transfer enables the reduction of heat exchanger size while maintaining performance. Reduction in equipment size is critical due to the ability to minimize the required volume of costly working fluids and to mitigate potential safety concerns associated with total system fluid volume. Here, a comprehensive review of single-phase heat transfer enhancement techniques is presented. The article provides a thorough comparison by analyzing the heat transfer rate, pressure drop, and other operational aspects. Single-phase heat transfer enhancement methods are divided into active and passive techniques. Active methods such as electrohydrodynamic (EHD), magnetohydrodynamics (MHD), or mechanical motion require external power to create enhancement. Passive methods such as dimples, fins, or tape inserts do not require external input and rely only on surface modification. Although active methods are more expensive and difficult to implement compared to passive techniques, it enables active control of heat transfer augmentation. Finally, this review develops and summarizes key learning data for design optimization enabled by additive manufacturing and machine learning algorithms, helping to inform these next-generation heat exchanger design methodologies for a plethora of modern applications such as electrification of vehicles, computing, and classical industries.

42 ENGINEERING↗

Laser Additive Manufacturing of F/M Steels for Radiation Tolerant Nuclear Components

According to the Nuclear Energy R&D Roadmap Report submitted to Congress in 2010, one the key challenges facing the nuclear energy industry involves development of new reactor designs with reduced capital costs. Two related R&D objectives outlined in the report include: 1) Making improvements in the affordability of new reactors; and 2) Development of structural materials to withstand irradiation for longer periods. Laser additive manufacturing (LAM) is particularly well suited for more rapid and economical fabrication of reactor components relative to current fabrication methods. The proposed work involving LAM directly addresses the two R&D objectives outlined above relevant to the pertinent mission problems. The classical Materials Science approach involving development of Process/Structure/Property/Performance (P/S/P/P) relations was employed in this project. Processing included LAM and heat-treating. Thermal cycling during LAM is discussed here, and phase diagrams and continuous cooling transformation (CCT) diagrams are used to rationalize microstructural evolution. Structures were characterized including grain size & morphology, volume fraction, morphology, composition and location of carbides in as-deposited and heat-treated conditions. In the simplest sense, the goal was to control microstructures through process manipulation with a view toward optimizing properties and performance in service.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A solid iodinated phantom material for use in tomographic x-ray imaging

PURPOSE: Iodinated phantoms are of value in x-ray imaging for quality control measurements, system calibration, and for use in the research setting; however, the liquid phantoms that are most often used have several limitations including variability between repeated dilutions, inhomogeneities from air bubbles or precipitants, and long set up times. Although suitable materials have been investigated for projection radiography, quantitative measurements of contrast enhancement in computed tomography (CT) have become increasingly important in the clinic, and a need exists for a durable and reproducible iodinated phantom material. In this work, the authors describe a solid radiographic phantom material that has an accurately known concentration of iodine distributed uniformly throughout its volume and that has stable properties over time. This material can be molded or machined into a desired shape to create a test object or for use in an anthropomorphic phantom. Methods: Two sets of calibration phantoms were produced with a clinically relevant range of iodine concentrations. Measurements were made on these phantoms to characterize the material properties in terms of accuracy of iodine concentration, radiographic uniformity, temporal stability of x-ray attenuation, and manufacturing repeatability. Experimentally measured linear x-ray attenuation coefficients were compared to those predicted by a theoretical model. The uniformity of the iodine distribution in the material was assessed by measuring image intensity variation, both in projection images and in reconstructed CT volumes. The reproducibility of manufacture was estimated on a set of independently produced samples. A longitudinal study was performed to assess the stability of the material x-ray characteristics over time by making measurements at 6 month intervals. Results: Good agreement was seen between the experimental measurements of effective attenuation and the theoretically predicted values. It is estimated that a desired iodine concentration could be produced to within 0.04 mg/ml. Comparison of the measured effective linear iodine attenuation coefficients of eight 1.0 mg/ml samples indicated a manufacturing reproducibility of {+-}0.03 mg/ml iodine. Variations in uniformity across each of the samples were on the order of image intensity fluctuations ({sigma}). No inhomogeneities due to mixing or settling were apparent. An analysis of longitudinal data collected for both calibration sets revealed no perceptible change in radiographic properties over the first 6 months after manufacture, nor over a subsequent 1.5 yr period from 1 yr postmanufacture onward. Conclusions: The uniformity, stability, and precision of this iodinated material suggest that it is suitable for use in accurate calibration tools for contrast tomographic imaging.

36 MATERIALS SCIENCE↗

Diffusion tensor imaging of the kidney in healthy controls and in children and young adults with autosomal recessive polycystic kidney disease

Objective: To compare diffusion tensor imaging (DTI) of the kidneys and its derived parameters in children with autosomal recessive polycystic kidney disease (ARPKD) versus healthy controls. Methods: In a prospective IRB-approved study, we evaluated the use of DTI to compare kidney parenchyma FA values in healthy controls (age-matched children with no history of renal disease) versus patients with ARPKD. A 20-direction DTI with b-values of b = 0 s/mm{sup 2} and b = 400 s/mm{sup 2} was used to acquire data in coronal direction using a fat-suppressed spin-echo echo-planar sequence. Diffusion Toolkit and TrackVis were used for analysis and segmentation. TrackVis was used to draw regions of interest (ROIs) covering the entire volume of the renal parenchyma, excluding the collecting system. Fibers were reconstructed using a deterministic fiber tracking algorithm. The FA values based on the ROI data, mean length, and volume of the tracks based on the fiber tracking data were recorded. Results: Eight healthy controls (mean age = 12.9 years ± 4.0; 1/8 males) and six ARPKD participants (mean age = 13.8 years ± 8.5; 5/6 males) were included in the study. Compared to healthy controls, patients with ARPKD had significantly lower FA values (0.33 ± 0.03 vs. 0.25 ± 0.02, p = 0.002) and mean track length (16.73 ± 3.43 vs. 11.61 ± 1.29 mm, p = 0.005). Conclusion: DTI of the kidneys shows significantly lower FA values and mean track length in children and young adults with ARPKD compared to normal subjects. DTI of the kidney offers a novel approach for characterizing renal disease based on changes in diffusion anisotropy and kidney structure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗