Search NASA⌕ Search

SEARCH · Search NASA

Results for “conversion methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Integrated CO 2 capture and hydrogenation in presence of Ru–Na 2 ZrO 3 : An in-situ study

Integrated CO 2 capture and conversion (ICCC) by hydrogenation is a promising strategy to utilize carbon dioxide and this work add to the effort to elucidate the catalytic hydrogenation mechanism using Ru based dual functional materials (DFM). Ru-Na 2 ZrO 3 DFMs, obtained through different wet methods, were evaluated for the first time and the relationship between Ru and support systematically investigated. The thermally stable and cyclable Ru-Na 2 ZrO 3 -a (obtained without filtration step) exhibited CO 2 conversion of 80% and a higher yield of CO at 400°C compared to previously tested DFM, while the Na depleted/Zr rich Ru-Na 2 ZrO 3 -b resulted in 90% selectivity to CH 4 with yield of 1.11 mmol/g at the same temperature. The in-situ experiments have provided conclusive evidence showing that CO 2 hydrogenation on the two Ru DFMs is fundamentally different. In Ru-Na 2 ZrO 3 -a, the monoclinic Na 2 ZrO 3 support acted as the active centre (not as promoter) for CO 2 bridging binding and hydrogenation to CH 4 at the metal-support interface through associative formate pathway with limited further reduction to methane due to lack of H 2 spillover from the small and well dispersed Ru NPs, which results in CO desorption. Conversely, abundant clusters of larger Ru NPs in Ru-Na 2 ZrO 3 -b, led to CH 4 production due to co-existent Ru on-top direct dissociation of CO 2 (preferential) and monodentate formate adsorption and further methanation. Alkali zirconates doped metals, and their synthesis method could thus play a crucial role in designing tuneable heterogeneous catalysis in C 1 chemistry, which could significantly benefit the environment by lowering CO 2 levels, encouraging cleaner industrial practices, supporting a circular economy, and converting waste CO 2 into valuable products.

36 MATERIALS SCIENCE↗

Particle size effect of redox reactions for Co species supported on silica

Conversions of chemical states during redox reactions of two silica-supported Co catalysts, which were prepared by the impregnation method, were evaluated by using an in situ XAFS technique. The addition of citric acid into the precursor solution led to the formation on silica of more homogeneous and smaller Co particles, with an average diameter of 4 nm. The supported Co{sub 3}O{sub 4} species were reduced to metallic Co via the divalent CoO species during a temperature-programmed reduction process. The reduced Co species were quantitatively oxidized with a temperature-programmed oxidation process. The higher observed reduction temperature of the smaller CoO particles and the lower observed oxidation temperature of the smaller metallic Co particles were induced by the higher dispersion of the Co oxide species, which apparently led to a stronger interaction with supporting silica. The redox temperature between CoO and Co{sub 3}O{sub 4} was found to be independent of the particle size. - Graphical abstract: Chemical state conversions of SiO{sub 2}-supported Co species and the particle size effect have been analyzed by means of in situ XAFS technique. The small CoO particles have endurance against the reduction and exist in a wide temperature range. Display Omitted - Highlights: • The conversions of the chemical state of supported Co species during redox reaction are evaluated. • In operando XAFS technique were applied to measure redox properties of small Co particles. • A small particle size affects to the redox temperatures of cobalt catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Woody Feedstock 2022 State of Technology Report

The U.S. Department of Energy promotes production of advanced liquid transportation fuels from lignocellulosic biomass by funding fundamental and applied research that advances the state of technology (SOT). As part of its involvement in this mission, Idaho National Laboratory completes an annual SOT report for n th -plant and 1 st -plant woody biomass feedstock logistics. The purpose of the SOT is to provide the status of feedstock supply system technology development for woody biomass to biofuels relative to technical targets and cost goals from specific design cases, based on data and experimental results. Conventional feedstock supply systems need to be modified to meet the demands of conversion pathways, specifically to have the ability to adjust the quality of the raw biomass materials. Advanced systems incorporate innovative methods of material handling, preprocessing and supply chain configuration. In advanced designs, variability of the raw biomass can be reduced to produce feedstocks of a uniform format, moving toward biomass commoditization. Against this backdrop, the 2022 Woody SOT for low-ash woody feedstocks utilizes feedstock fractionation by incorporating technologies that can separate the biomass into its anatomical fractions (wood, bark, needle, and extrinsic ash) to reduce impurities and attempt to maximize the retention of usable fractions that satisfy downstream quality considerations. By using a series of air classification steps, this strategy can reduce the extrinsic ash in forest residues, separate out a majority of the incoming needles (which can be supplied to alternate markets), and maximize the retention of whitewood in the usable fraction. The fractionated forest residues are then mixed with clean-pine chips in a 50-50 blend to prepare the feedstock for the desired conversion pathway. The n th -plant analysis estimated the delivered cost for the feedstock at $\$$69.23/dry ton (2016$\$$) which represents a $\$$6.64/dry ton decrease compared to the cost estimate of the 2021 Woody SOT supply system for low-ash woody feedstocks. The quality requirements in the 2022 Woody SOT were identical to those of the 2021 Woody SOT at = 1.00 wt % ash and = 50.51 wt% carbon. The cost savings derive primarily from reductions in dry matter losses during air classification. The GHG emissions for the n th -plant analysis were estimated at 178.39 kg CO2e/dry ton compared to 178.71 kg CO 2 e/dry ton in the 2021 Woody SOT, a decrease of 0.32 kg CO2e/dry ton. The small change stems from an increase in emissions attributed to preprocessing and slightly larger savings in emissions from transportation. In the 1 st -plant analysis of the 2022 Woody SOT system, the average throughput was estimated to be approximately 2,128 dry tons/day or 96.51% of the name plate capacity. During the simulation the daily throughput ranged from 1,090 dry tons/day to 2,200 dry tons/day, or 49.43% to 99.75% of the daily nameplate capacity. After the year of operation 722,403 tons of processed feedstock were produced in total without regard to quality considerations (99.64% of the annual nameplate capacity). The variability in throughput was primarily caused by equipment failures in the system. Regular failures, downtime caused by routine maintenance per manufacturer guidelines, contributed to a majority 62.50% of failures and 62.60% of downtime. Failures due to wear were the other cause of disruption within the system, impacting the rotary shear and orbital screen and accounting for 37.50% of the failures and 37.40% of the total downtime. Ultimately the system was on stream for 87.84% during the simulation period, which is only 2.16 percentage points below the nth-plant assumption for on-stream time. The production cost of the system averaged $\$$71.66/dry ton. The costs ranged from a minimum of $\$$71.23/dry ton to a maximum of $\$$2,115.30/dry ton. When dry matter losses (disposed low-quality fractions as well as other losses such as in grinders) were considered the costs increased to an average of $\$$75.11/dry ton with a minimum of $\$$74.69/dry ton and a maximum of $\$$2,136.86/dry ton...

09 BIOMASS FUELS↗

Effect of Ce/Zr molar ratio on the performance of Cu–Ce{sub x}–Zr{sub 1−x}/TiO{sub 2} catalyst for selective catalytic reduction of NO{sub x} with NH{sub 3} in diesel exhaust

Graphical abstract: The Cu–Ce{sub 0.25}–Zr{sub 0.75}/TiO{sub 2} catalyst exhibited excellent SCR activity at 165–450 °C within the range of exhaust temperatures of diesel engines. - Highlights: • Cu–Ce{sub x}–Zr{sub 1−x}/TiO{sub 2} catalysts were prepared by a wet impregnation method. • The property for NH{sub 3}-selective catalytic reduction of NO{sub x} were investigated. • The Ce/Zr molar ratio had effects on the performance of Cu–Ce–Zr/TiO{sub 2} catalysts. • The Cu–Ce{sub 0.25}–Zr{sub 0.75}/TiO{sub 2} sample exhibited 100% NO{sub x} conversion between 165 °C and 450 °C. • The factors that govern the activity enhancement were extensively investigated. - Abstract: Copper–cerium–zirconium catalysts loaded on TiO{sub 2} prepared by a wet impregnation method were investigated for NH{sub 3}-selective catalytic reduction of NO{sub x}, aiming to study the effects of the Ce/Zr molar ratio on the performance of Cu–Ce–Zr/TiO{sub 2} catalysts. The Cu–Ce{sub 0.25}–Zr{sub 0.75}/TiO{sub 2} sample exhibited nearly 100% NO{sub x} conversion over a wide temperature range (165–450 °C), which is strikingly superior to that of Cu/TiO{sub 2} (210–389 °C) within the range of exhaust temperatures of diesel engines. The factors that govern the activity enhancement were extensively investigated by using a series of characterization techniques, namely X-ray diffraction (XRD), transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS) and temperature-programmed reduction by hydrogen (H{sub 2}-TPR). The results showed that the addition of zirconium and/or cerium refined the copper dispersion, prevented copper crystallization and partially incorporated the copper ions into the zirconia (ceira) lattice, which led to enhance the redox abilities of Cu–Ce–Zr/TiO{sub 2} catalysts.

36 MATERIALS SCIENCE↗

Catlas: an automated framework for catalyst discovery demonstrated for direct syngas conversion

Catalyst discovery is paramount to support access to energy and key chemical feedstocks in a post fossil fuel era. Exhaustive computational searches of large material design spaces using ab initio methods like density functional theory (DFT) are infeasible. We seek to explore large design spaces at relatively low computational cost by leveraging large, generalized, graph-based machine learning (ML) models, which are pretrained and therefore require no upfront data collection or training. We present Catlas, a framework that distributes and automates the generation of adsorbate-surface configurations and ML inference of DFT energies to achieve this goal. Catlas is open source, making ML assisted catalyst screenings easy and available to all. To demonstrate its efficacy, we use Catlas to explore catalyst candidates for the direct conversion of syngas to multi-carbon oxygenates. For this case study, we explore 947 stable/metastable binary, transition metal intermetallics as possible catalyst candidates. On this subset of materials, we are able to predict the adsorption energy of key descriptors, *CO and *OH, with good accuracy (0.16, 0.14 eV MAE, respectively). Using the projected selectivity towards C 2+ oxygenates from an existing microkinetic model, we identified 144 candidate materials. For 10 promising candidates, DFT calculations reveal a good correlation with our assessment using ML. Finally, among the top elemental combinations were Pt–Ti, Pd–V, Ni–Nb, and Ti–Zn, all of which appear unexplored experimentally.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TU-F-BRB-03: Clinical Implementation of MR-Based Motion Management

The current clinical standard of organ respiratory imaging, 4D-CT, is fundamentally limited by poor soft-tissue contrast and imaging dose. These limitations are potential barriers to beneficial “4D” radiotherapy methods which optimize the target and OAR dose-volume considering breathing motion but rely on a robust motion characterization. Conversely, MRI imparts no known radiation risk and has excellent soft-tissue contrast. MRI-based motion management is therefore highly desirable and holds great promise to improve radiotherapy of moving cancers, particularly in the abdomen. Over the past decade, MRI techniques have improved significantly, making MR-based motion management clinically feasible. For example, cine MRI has high temporal resolution up to 10 f/s and has been used to track and/or characterize tumor motion, study correlation between external and internal motions. New MR technologies, such as 4D-MRI and MRI hybrid treatment machines (i.e. MR-linac or MR-Co60), have been recently developed. These technologies can lead to more accurate target volume determination and more precise radiation dose delivery via direct tumor gating or tracking. Despite all these promises, great challenges exist and the achievable clinical benefit of MRI-based tumor motion management has yet to be fully explored, much less realized. In this proposal, we will review novel MR-based motion management methods and technologies, the state-of-the-art concerning MRI development and clinical application and the barriers to more widespread adoption. Learning Objectives: Discuss the need of MR-based motion management for improving patient care in radiotherapy. Understand MR techniques for motion imaging and tumor motion characterization. Understand the current state of the art and future steps for clinical integration. Henry Ford Health System holds research agreements with Philips Healthcare. Research sponsored in part by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

TU-PIS-Exhibit Hall-1: Tools for Collecting and Analyzing Patient Dose Index Information from Imaging Equipment

The current clinical standard of organ respiratory imaging, 4D-CT, is fundamentally limited by poor soft-tissue contrast and imaging dose. These limitations are potential barriers to beneficial “4D” radiotherapy methods which optimize the target and OAR dose-volume considering breathing motion but rely on a robust motion characterization. Conversely, MRI imparts no known radiation risk and has excellent soft-tissue contrast. MRI-based motion management is therefore highly desirable and holds great promise to improve radiotherapy of moving cancers, particularly in the abdomen. Over the past decade, MRI techniques have improved significantly, making MR-based motion management clinically feasible. For example, cine MRI has high temporal resolution up to 10 f/s and has been used to track and/or characterize tumor motion, study correlation between external and internal motions. New MR technologies, such as 4D-MRI and MRI hybrid treatment machines (i.e. MR-linac or MR-Co60), have been recently developed. These technologies can lead to more accurate target volume determination and more precise radiation dose delivery via direct tumor gating or tracking. Despite all these promises, great challenges exist and the achievable clinical benefit of MRI-based tumor motion management has yet to be fully explored, much less realized. In this proposal, we will review novel MR-based motion management methods and technologies, the state-of-the-art concerning MRI development and clinical application and the barriers to more widespread adoption. Learning Objectives: Discuss the need of MR-based motion management for improving patient care in radiotherapy. Understand MR techniques for motion imaging and tumor motion characterization. Understand the current state of the art and future steps for clinical integration. Henry Ford Health System holds research agreements with Philips Healthcare. Research sponsored in part by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

TU-PIS-Exhibit Hall-2: How to Move Beyond Dose Monitoring to Imaging Performance Utilization

The current clinical standard of organ respiratory imaging, 4D-CT, is fundamentally limited by poor soft-tissue contrast and imaging dose. These limitations are potential barriers to beneficial “4D” radiotherapy methods which optimize the target and OAR dose-volume considering breathing motion but rely on a robust motion characterization. Conversely, MRI imparts no known radiation risk and has excellent soft-tissue contrast. MRI-based motion management is therefore highly desirable and holds great promise to improve radiotherapy of moving cancers, particularly in the abdomen. Over the past decade, MRI techniques have improved significantly, making MR-based motion management clinically feasible. For example, cine MRI has high temporal resolution up to 10 f/s and has been used to track and/or characterize tumor motion, study correlation between external and internal motions. New MR technologies, such as 4D-MRI and MRI hybrid treatment machines (i.e. MR-linac or MR-Co60), have been recently developed. These technologies can lead to more accurate target volume determination and more precise radiation dose delivery via direct tumor gating or tracking. Despite all these promises, great challenges exist and the achievable clinical benefit of MRI-based tumor motion management has yet to be fully explored, much less realized. In this proposal, we will review novel MR-based motion management methods and technologies, the state-of-the-art concerning MRI development and clinical application and the barriers to more widespread adoption. Learning Objectives: Discuss the need of MR-based motion management for improving patient care in radiotherapy. Understand MR techniques for motion imaging and tumor motion characterization. Understand the current state of the art and future steps for clinical integration. Henry Ford Health System holds research agreements with Philips Healthcare. Research sponsored in part by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

TU-PIS-Exhibit Hall-3: Simultaneous tracking of patient and real time staff dose to optimize interventional workflow

The current clinical standard of organ respiratory imaging, 4D-CT, is fundamentally limited by poor soft-tissue contrast and imaging dose. These limitations are potential barriers to beneficial “4D” radiotherapy methods which optimize the target and OAR dose-volume considering breathing motion but rely on a robust motion characterization. Conversely, MRI imparts no known radiation risk and has excellent soft-tissue contrast. MRI-based motion management is therefore highly desirable and holds great promise to improve radiotherapy of moving cancers, particularly in the abdomen. Over the past decade, MRI techniques have improved significantly, making MR-based motion management clinically feasible. For example, cine MRI has high temporal resolution up to 10 f/s and has been used to track and/or characterize tumor motion, study correlation between external and internal motions. New MR technologies, such as 4D-MRI and MRI hybrid treatment machines (i.e. MR-linac or MR-Co60), have been recently developed. These technologies can lead to more accurate target volume determination and more precise radiation dose delivery via direct tumor gating or tracking. Despite all these promises, great challenges exist and the achievable clinical benefit of MRI-based tumor motion management has yet to be fully explored, much less realized. In this proposal, we will review novel MR-based motion management methods and technologies, the state-of-the-art concerning MRI development and clinical application and the barriers to more widespread adoption. Learning Objectives: Discuss the need of MR-based motion management for improving patient care in radiotherapy. Understand MR techniques for motion imaging and tumor motion characterization. Understand the current state of the art and future steps for clinical integration. Henry Ford Health System holds research agreements with Philips Healthcare. Research sponsored in part by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

TU-PIS-Exhibit Hall-4: How to implement a dose monitoring solution in the real world: a technical perspective

The current clinical standard of organ respiratory imaging, 4D-CT, is fundamentally limited by poor soft-tissue contrast and imaging dose. These limitations are potential barriers to beneficial “4D” radiotherapy methods which optimize the target and OAR dose-volume considering breathing motion but rely on a robust motion characterization. Conversely, MRI imparts no known radiation risk and has excellent soft-tissue contrast. MRI-based motion management is therefore highly desirable and holds great promise to improve radiotherapy of moving cancers, particularly in the abdomen. Over the past decade, MRI techniques have improved significantly, making MR-based motion management clinically feasible. For example, cine MRI has high temporal resolution up to 10 f/s and has been used to track and/or characterize tumor motion, study correlation between external and internal motions. New MR technologies, such as 4D-MRI and MRI hybrid treatment machines (i.e. MR-linac or MR-Co60), have been recently developed. These technologies can lead to more accurate target volume determination and more precise radiation dose delivery via direct tumor gating or tracking. Despite all these promises, great challenges exist and the achievable clinical benefit of MRI-based tumor motion management has yet to be fully explored, much less realized. In this proposal, we will review novel MR-based motion management methods and technologies, the state-of-the-art concerning MRI development and clinical application and the barriers to more widespread adoption. Learning Objectives: Discuss the need of MR-based motion management for improving patient care in radiotherapy. Understand MR techniques for motion imaging and tumor motion characterization. Understand the current state of the art and future steps for clinical integration. Henry Ford Health System holds research agreements with Philips Healthcare. Research sponsored in part by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

TU-PIS-Exhibit Hall-5: Use of the Enterprise-wide Dose Tracking Software Radimetrics In an Academic Medical System

The current clinical standard of organ respiratory imaging, 4D-CT, is fundamentally limited by poor soft-tissue contrast and imaging dose. These limitations are potential barriers to beneficial “4D” radiotherapy methods which optimize the target and OAR dose-volume considering breathing motion but rely on a robust motion characterization. Conversely, MRI imparts no known radiation risk and has excellent soft-tissue contrast. MRI-based motion management is therefore highly desirable and holds great promise to improve radiotherapy of moving cancers, particularly in the abdomen. Over the past decade, MRI techniques have improved significantly, making MR-based motion management clinically feasible. For example, cine MRI has high temporal resolution up to 10 f/s and has been used to track and/or characterize tumor motion, study correlation between external and internal motions. New MR technologies, such as 4D-MRI and MRI hybrid treatment machines (i.e. MR-linac or MR-Co60), have been recently developed. These technologies can lead to more accurate target volume determination and more precise radiation dose delivery via direct tumor gating or tracking. Despite all these promises, great challenges exist and the achievable clinical benefit of MRI-based tumor motion management has yet to be fully explored, much less realized. In this proposal, we will review novel MR-based motion management methods and technologies, the state-of-the-art concerning MRI development and clinical application and the barriers to more widespread adoption. Learning Objectives: Discuss the need of MR-based motion management for improving patient care in radiotherapy. Understand MR techniques for motion imaging and tumor motion characterization. Understand the current state of the art and future steps for clinical integration. Henry Ford Health System holds research agreements with Philips Healthcare. Research sponsored in part by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

TU-F-BRB-00: MRI-Based Motion Management for RT

The current clinical standard of organ respiratory imaging, 4D-CT, is fundamentally limited by poor soft-tissue contrast and imaging dose. These limitations are potential barriers to beneficial “4D” radiotherapy methods which optimize the target and OAR dose-volume considering breathing motion but rely on a robust motion characterization. Conversely, MRI imparts no known radiation risk and has excellent soft-tissue contrast. MRI-based motion management is therefore highly desirable and holds great promise to improve radiotherapy of moving cancers, particularly in the abdomen. Over the past decade, MRI techniques have improved significantly, making MR-based motion management clinically feasible. For example, cine MRI has high temporal resolution up to 10 f/s and has been used to track and/or characterize tumor motion, study correlation between external and internal motions. New MR technologies, such as 4D-MRI and MRI hybrid treatment machines (i.e. MR-linac or MR-Co60), have been recently developed. These technologies can lead to more accurate target volume determination and more precise radiation dose delivery via direct tumor gating or tracking. Despite all these promises, great challenges exist and the achievable clinical benefit of MRI-based tumor motion management has yet to be fully explored, much less realized. In this proposal, we will review novel MR-based motion management methods and technologies, the state-of-the-art concerning MRI development and clinical application and the barriers to more widespread adoption. Learning Objectives: Discuss the need of MR-based motion management for improving patient care in radiotherapy. Understand MR techniques for motion imaging and tumor motion characterization. Understand the current state of the art and future steps for clinical integration. Henry Ford Health System holds research agreements with Philips Healthcare. Research sponsored in part by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

TU-F-BRB-01: Resolving and Characterizing Breathing Motion for Radiotherapy with MRI

The current clinical standard of organ respiratory imaging, 4D-CT, is fundamentally limited by poor soft-tissue contrast and imaging dose. These limitations are potential barriers to beneficial “4D” radiotherapy methods which optimize the target and OAR dose-volume considering breathing motion but rely on a robust motion characterization. Conversely, MRI imparts no known radiation risk and has excellent soft-tissue contrast. MRI-based motion management is therefore highly desirable and holds great promise to improve radiotherapy of moving cancers, particularly in the abdomen. Over the past decade, MRI techniques have improved significantly, making MR-based motion management clinically feasible. For example, cine MRI has high temporal resolution up to 10 f/s and has been used to track and/or characterize tumor motion, study correlation between external and internal motions. New MR technologies, such as 4D-MRI and MRI hybrid treatment machines (i.e. MR-linac or MR-Co60), have been recently developed. These technologies can lead to more accurate target volume determination and more precise radiation dose delivery via direct tumor gating or tracking. Despite all these promises, great challenges exist and the achievable clinical benefit of MRI-based tumor motion management has yet to be fully explored, much less realized. In this proposal, we will review novel MR-based motion management methods and technologies, the state-of-the-art concerning MRI development and clinical application and the barriers to more widespread adoption. Learning Objectives: Discuss the need of MR-based motion management for improving patient care in radiotherapy. Understand MR techniques for motion imaging and tumor motion characterization. Understand the current state of the art and future steps for clinical integration. Henry Ford Health System holds research agreements with Philips Healthcare. Research sponsored in part by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

TU-F-BRB-02: Motion Artifacts and Suppression in MRI

The current clinical standard of organ respiratory imaging, 4D-CT, is fundamentally limited by poor soft-tissue contrast and imaging dose. These limitations are potential barriers to beneficial “4D” radiotherapy methods which optimize the target and OAR dose-volume considering breathing motion but rely on a robust motion characterization. Conversely, MRI imparts no known radiation risk and has excellent soft-tissue contrast. MRI-based motion management is therefore highly desirable and holds great promise to improve radiotherapy of moving cancers, particularly in the abdomen. Over the past decade, MRI techniques have improved significantly, making MR-based motion management clinically feasible. For example, cine MRI has high temporal resolution up to 10 f/s and has been used to track and/or characterize tumor motion, study correlation between external and internal motions. New MR technologies, such as 4D-MRI and MRI hybrid treatment machines (i.e. MR-linac or MR-Co60), have been recently developed. These technologies can lead to more accurate target volume determination and more precise radiation dose delivery via direct tumor gating or tracking. Despite all these promises, great challenges exist and the achievable clinical benefit of MRI-based tumor motion management has yet to be fully explored, much less realized. In this proposal, we will review novel MR-based motion management methods and technologies, the state-of-the-art concerning MRI development and clinical application and the barriers to more widespread adoption. Learning Objectives: Discuss the need of MR-based motion management for improving patient care in radiotherapy. Understand MR techniques for motion imaging and tumor motion characterization. Understand the current state of the art and future steps for clinical integration. Henry Ford Health System holds research agreements with Philips Healthcare. Research sponsored in part by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

Best Practices and Testing Protocols for Benchmarking ORR Activities of Fuel Cell Electrocatalysts Using Rotating Disk Electrode

Abstract Thin-film-rotating disk electrodes (TF-RDEs) are the half-cell electrochemical system of choice for rapid screening of oxygen reduction reaction (ORR) activity of novel Pt supported on carbon black supports (Pt/C) electrocatalysts. It has been shown that the magnitude of the measured ORR activity and reproducibility are highly dependent on the system cleanliness, evaluation protocols, and operating conditions as well as ink formulation, composition, film drying, and the resultant film thickness and uniformity. Accurate benchmarks of baseline Pt/C catalysts evaluated using standardized protocols and best practices are necessary to expedite ultra-low-platinum group metal (PGM) catalyst development that is crucial for the imminent commercialization of fuel cell vehicles. We report results of evaluation in three independent laboratories of Pt/C electrocatalysts provided by commercial fuel cell catalyst manufacturers (Johnson Matthey, Umicore, Tanaka Kikinzoku Kogyo—TKK). The studies were conducted using identical evaluation protocols/ink formulation/film fabrication albeit employing unique electrochemical cell designs specific to each laboratory. The ORR activities reported in this work provide a baseline and criteria for selection and scale-up of novel high activity ORR electrocatalysts for implementation in proton exchange membrane fuel cells (PEMFCs).

Kocha, Shyam S.↗

Multifunctional transitional metal-based phosphide nanoparticles towards improved polysulfide confinement and redox kinetics for highly stable lithium-sulfur batteries

The shuttle effect and the sluggish redox kinetics of lithium polysulfides (LiPSs) are the major issues impeding the practical applications of lithium-sulfur batteries (LSBs). Herein, a highly-efficient Ni 2 P electrocatalyst supported on N, P co-doped graphene (Ni 2 P@NPG) is developed via a simple “recrystallization-self-assembly” method to address the above issues. Here, the ultrafine Ni 2 P nanoparticles ensure abundant adsorption-diffusion-conversion interfaces for accelerating LiPSs transformation and Li 2 S deposition, which extremely decreases the accumulation of LiPSs in the electrolyte and therefore prevents the migration of LiPSs. Their superior catalytic performance is demonstrated by reduced Gibbs free energy changes of rate-limiting step based on the systematic theoretical calculations and the reduced shuttle effect is tested by the three-dimensional reconstructions of Raman depth profiles. Benefiting from these synergistic effects, the LSBs with Ni 2 P@NPG modified separators present a superior cycling performance with an average capacity decay rate of 0.048 % per cycle at 1C around the 400 cycles and a high-rate capacity of 731 mAh/g at 2C. Even with a high-sulfur loading of 3.53 mg cm –2 , the cell can still contain a reversible capacity of 809 mAh/g at 0.2C with a remarkable columbic efficiency of 98.4 %.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interfacial Structure and Electric Field Probed by in Situ Electrochemical Vibrational Stark Effect Spectroscopy and Computational Modeling

Interfacial electric fields play crucial roles in electrochemistry, catalysis, and solar energy conversion. Understanding of the interfacial electric field effects has been hindered by the lack of a direct spectroscopic method to probe of the interfacial field at the molecular level. Here, we report the characterization of the field and interfacial structure at Au/diisocyanide/aqueous electrolyte interfaces, using a combination of in situ electrochemical vibrational sum frequency generation (SFG) spectroscopy, density functional theory (DFT) calculations, and molecular dynamics (MD) simulations. For 1,4-phenylene diisocyanide (PDI), 4,4'-biphenyl diisocyanide (BPDI), and 4,4"-p-terphenyl diisocyanide (TPDI), our results reveal that the frequency of the gold-bound NC stretch mode of the diisocyanide self-assembled monolayer (SAM) increases linearly with the applied potential, suggesting that SFG can be an in situ probe of the strength of the electric field at electrode/electrolyte interfaces. Using DFT-computed Stark tuning rates of model complexes, the electric field strength at the metal/SAM/electrolyte interfaces is estimated to be 108–109 V/m. The linear dependence of the vibrational frequency (and field) with applied potential is consistent with an electrochemical double-layer structure that consists of a Helmholtz layer in contact with a diffused layer. The Helmholtz layer thickness is approximately the same as the molecular length for PDI, suggesting a well-ordered SAM with negligible electrolyte penetration. For BPDI and TPDI, we found that the Helmholtz layer is thinner than the monolayer of molecular adsorbates, indicating that the electrolyte percolates into the SAM, as shown by molecular dynamics simulations of the Au/PDI/electrolyte interface. The reported analysis demonstrates that a combination of in situ SFG probes and computational modeling provides a powerful approach to elucidate the structure of electrochemical interfaces at the detailed molecular level.

Ge, Aimin↗