Search NASA⌕ Search

SEARCH · Search NASA

Results for “diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Upgrade of the ECE diagnostic on EAST

The electron cyclotron emission (ECE) diagnostic on the experimental advanced superconducting tokamak (EAST) was upgraded recently to provide electron temperature profile measurement with wider radial coverage and better precision. Here, the lower limit of the ECE detection frequency band was extended from 104 GHz to 97 GHz by adding a new 8-channel heterodyne radiometer, which ensures capability for the measurement of the second harmonic ECE with toroidal magnetic field down to 1.75 T. Also, the existing 32-channel heterodyne radiometer has been upgraded, with the frequency interval for the lower frequency range up to 120 GHz reduced from 2 GHz to 1 GHz by introducing eight channels in the intermediate frequency part. In addition, a plan is presented to incorporate tunable yttrium iron garnet filters into the existing heterodyne radiometer to obtain detailed measurements of the electron temperature gradient scale length as well as finer spatial pinpointing of magnetohydrodynamic modes. Examples from DIII-D are provided where similar ECE diagnostic allowed precise measurement of the center and width of neoclassical tearing modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Examination of synthetic gas puff imaging diagnostic data from a gyrokinetic turbulence code

A synthetic gas puff imaging (GPI) diagnostic has been developed for the purpose of validating the three-dimensional gyrokinetic turbulence code XGC. The synthetic diagnostic is described and applied to XGC simulations of two Alcator C-Mod discharges. The turbulence characteristics deduced from the resulting simulated GPI frames, using analysis techniques similar to those applied to experimental data, are compared with locally derived characteristics extracted directly from the XGC output. The comparison of the two is shown to be potentially impacted by misalignment between the GPI view and the magnetic field, the dependence of the light emission on the electron density and temperature, and spatial and temporal variations in the neutral gas cloud induced by the turbulent plasma fluctuations. We conclude that quantitative and, in some cases even qualitative, validation of turbulence simulations need to account for these effects. While we cannot directly compare our results with experimental data due to the absence of high quality GPI data from the shots and times simulated by XGC, we do relate the overall characteristics obtained from the synthetic GPI analysis to published Alcator C-Mod GPI data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of microwave broadband CMOS transmitter and receiver circuits for MIR and ECEI plasma diagnostics

To efficiently determine the plasma electron density fluctuations using the MIR diagnostic technique, a 55–75 GHz 65 nm-CMOS transmitter has been developed where four separate intermediate frequency (IF) signals are up-converted, amplified, and then combined to generate an 8-tone RF output; a broadband 90 nm-CMOS receiver has also been constructed, which consists of an RF-low noise amplifier (LNA), mixer, and IF amplifier. The circuits and their corresponding modules will soon be deployed on the DIII-D and NSTX-U fusion devices. A 110–140 GHz 65 nm-CMOS receiver has also been designed, which is suitable for measuring the deep-core temperature fluctuations in the DIII-D tokamak using the electron cyclotron emission imaging diagnostic system. In addition to the RF-LNA/balun, mixer, and IF amplifier, an LO balun/tripler and driving amplifier are now included in this highly integrated circuit chip. By adopting the microwave and millimeterwave system-on-chip concept in the front-end system design, this paper demonstrates that compact transmitter and receiver modules can be easily built, which, in turn, facilitates array implementation and maintenance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Upgrades to the ion cyclotron emission diagnostic on the DIII-D tokamak

The ion cyclotron emission diagnostic on the DIII-D tokamak comprises seven single-turn loops that measure high-frequency (1–100 MHz) magnetic field fluctuations that are often excited by energetic particles in the plasma. The raw voltage signals induced in the loops in response to these fluctuations travel through a series of cables, isolation transformer DC blocks, low-pass filters, and finally a digitizer before being analyzed in frequency space. The diagnostic has been recently upgraded, most notably to include four additional graphite tile loops and a new eight-channel digitizer. The previous three loops are all on the low-field side of the tokamak. The measurement capabilities of the system have been expanded by the addition of a new horizontally oriented loop on the low-field side, an additional toroidal loop on the low-field side, and two toroidal loops on the high-field side. These loops will be used to provide approximate mode polarization, improved toroidal mode number calculations, and information on modes in inward-shifted plasmas, respectively.

47 OTHER INSTRUMENTATION↗

Calibration of a versatile multi-energy soft x-ray diagnostic for WEST long pulse plasmas

A compact multi-energy soft x-ray diagnostic is being installed on the W Environment in Steady-state Tokamak (WEST), which was designed and built to test ITER-like tungsten plasma facing components in a long pulse (~1000 s) scenario. The diagnostic consists of a pinhole camera fielded with the PILATUS3 photon-counting Si-based detector (≲100 kpixel). The detector has sensitivity in the range 1.6–30 keV and enables energy discrimination, providing a higher energy resolution than conventional systems with metal foils and diodes with adequate space and time resolution (≲1 cm and 2 ms). The lower-absorption cut-off energy is set independently on each one of the ~100 kpixels, providing a unique opportunity to measure simultaneously the plasma emissivity in multiple energy ranges and deduce a variety of plasma parameters (e.g., T e , n Z , and ΔZ eff ). The energy dependence of each pixel is calibrated here over the range 3–22 keV. The detector is exposed to a variety of monochromatic sources—fluorescence emission from metallic targets—and for each pixel, the lower energy threshold is scanned to calibrate the energy dependence. The data are fit to a responsivity curve (“S-curve”) that determines the mapping between the possible detector settings and the energy response for each pixel. Here, the calibration is performed for three energy ranges: low (2.3–6 keV), medium (4.5–13.5 keV), and high (5.4–21 keV). We determine the achievable energy resolutions for the low, medium, and high energy ranges as 330 eV, 640 eV, and 950 eV, respectively. The main limitation for the energy resolution is found to be the finite width of the S-curve.

47 OTHER INSTRUMENTATION↗

Optimization of the gamma reaction history diagnostic for double-shell pusher areal density and reaction history measurements on the National Ignition Facility

The double-shell inertial confinement fusion campaign, which consists of an aluminum ablator, a foam cushion, a high-Z pusher (tungsten or molybdenum), and liquid deuterium–tritium (DT) fuel, aims for its first DT filled implosions on the National Ignition Facility (NIF) in 2024. The high-Z, high density pusher does not allow x-rays to escape the double-shell capsule. Therefore, nuclear diagnostics such as the Gamma Reaction History (GRH) diagnostic on the NIF are crucial for understanding high-Z implosion performance. To optimize the GRH measurement of fusion reaction history and the pusher’s areal density, the MCNP6.3-based forward model of the detector was built. When calculating the neutron-induced inelastic gamma ray production, the interaction of neutrons with the compressed fuel was additionally included. By folding the calculated gamma ray spectrum output and the previously calibrated GRH detector responses, the optimum set of GRH energy thresholds for measuring the pusher areal density is determined to be 2.9 and 6.3 MeV for DT double-shell experiments. In addition, the effect of the down-scattering of neutrons on the gamma ray spectrum, the minimum required yield for measurements, and the attenuation of the gamma rays through the pusher are analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress toward absolute calibrations of DC x-ray sources from 1 keV to >30 keV for Z diagnostics applications

Numerous x-ray diagnostics at the Z facility, time-resolved and time-integrated, would benefit from a local calibrated x-ray source. For many years, Z has used low-power Manson x-ray sources to provide some characterization information for components of Z diagnostics below 30 keV. More recently, we have acquired TruFocus x-ray sources, which operate at voltages up to 100 kV depending on the anode material and model. These DC sources have demonstrated good stability and repeatability. Absolute calibrations of either sources or detectors usually involve another calibrated detector from another source, which has not been readily available locally. Therefore, we have adopted the strategy of characterizing a sensitive semiconductor diode detector by controlling or inferring the active volume. This characterized detector is then used to scale the Manson x-ray spectral shape as measured by an Amptek energy-resolving detector. Here, the result agrees well with the modeled source spectrum. We can apply this technique to the TruFocus as well.

Crystal spectroscopy↗

A new synthetic correlation electron cyclotron emission diagnostic for validating nonlinear gyrokinetic simulations of electron temperature turbulence

To validate nonlinear gyrokinetic simulations of electron temperature turbulence, the experimental correlation electron cyclotron emission (CECE) measurements are to be compared using a synthetic CECE diagnostic, which generates modeled CECE measurement quantities by implementing realistic measurement parameters (e.g., spatial and wavenumber resolutions, radial location, etc.) to nonlinear gyrokinetic simulations. In this work, we calculate the radial and vertical spatial and wavenumber transfer functions, which are defined by the electron cyclotron emission emissivity radial profile and vertical probing antenna pattern, respectively. These transfer functions are applied to nonlinear gyrokinetic simulations of electron temperature turbulence using the continuum gyrokinetic code. A simultaneous comparison of the experimental electron temperature turbulence power spectrum and root-mean-square (RMS) level, as well as the radial correlation length with the new synthetic CECE diagnostic at a core location ρ ∼ 0.75 in an L-mode DIII-D tokamak plasma, is presented. Here, the preliminary result shows that the synthetic CECE output underestimates the RMS level by ∼42% and overestimates the radial correlation length by ∼40%.

Cyclotron radiation↗

LAMP Diagnostics at the Point-of-Care: Emerging Trends and Perspectives for the Developer Community

Over the past decade, loop-mediated isothermal amplification (LAMP) technology has played an important role in molecular diagnostics. Amongst numerous nucleic acid amplification assays, LAMP stands out in terms of sample-to-answer time, sensitivity, specificity, cost, robustness, and accessibility, making it ideal for field-deployable diagnostics in resource-limited regions. In this review, we outline the front-end LAMP design practices for point-of-care (POC) applications, including sample handling and various signal readout methodologies. Next, we explore existing LAMP technologies that have been validated with clinical samples in the field. We summarize recent work that utilizes reverse transcription (RT) LAMP to rapidly detect SARS-CoV-2 as an alternative to standard PCR protocols. Finally, we describe challenges in translating LAMP from the benchtop to the field and opportunities for future LAMP assay development and performance reporting. Despite the popularity of LAMP in the academic research community and a recent surge in interest in LAMP due to the COVID-19 pandemic, there are numerous areas for improvement in the fundamental understanding of LAMP, which are needed to elevate the field of LAMP assay development and characterization.

60 APPLIED LIFE SCIENCES↗

Liquid Metal Diagnostics

Liquid metal (LM) plasma-facing components (PFCs) (LM-PFCs) within next-generation fusion reactors are expected to enhance plasma confinement, facilitate tritium breeding, improve reactor thermal efficiency, and withstand large heat and particle fluxes better than solid components made from tungsten, molybdenum, or graphite. Some LM divertor concepts intended for long-pulse operation at >20 MW/m 2 incorporate thin (~1 cm), fast-moving (~5 to 10 m/s), free-surface flows. Such systems will require a range of diagnostics to monitor and control the velocity, flow depth, temperature, and impurity concentration of the LM. As such, this paper will highlight technologies developed for the fission and casting/metallurgical industries that can be adapted to meet the needs of LM-PFC research. This paper is divided into four major parts. The first part will look at noncontact flowmeter technologies that are suitable for high-temperature alkali metal systems. These technologies include rotating Lorentz-force flowmeters for bulk flow rate measurements and particle tracking techniques for surface velocity measurements. Second, this paper will detail the operation of a new inductive level sensor that can be used within free-surface LM-PFCs. This robust level sensor can be mounted below the substrate that supports the LM, so it is simple to install and is protected from the damaging conditions inside a fusion reactor. It has been shown that this level sensor can be calibrated using either numerical or experimental techniques. Third, distributed temperature sensors based on fiber-optic technologies will be discussed. This advanced measurement technique provides temperature data with high spatial resolution and has recently been successfully tested in LM systems. Last, diagnostics to measure impurity concentration, such as electrochemical cells, plugging meters, and spectroscopic systems, will be addressed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PLASMA DIAGNOSTIC POTENTIAL OF 2p4f IN N{sup +}—ACCURATE WAVELENGTHS AND OSCILLATOR STRENGTHS

Radiative emission lines from nitrogen and its ions are often observed in nebula spectra, where the N{sup 2+} abundance can be inferred from lines of the 2p4f configuration. In addition, intensity ratios between lines of the 2p3p-2p3s and 2p4f-2p3d transition arrays can serve as temperature diagnostics. To aid abundance determinations and plasma diagnostics, wavelengths and oscillator strengths were calculated with high precision for electric dipole (E1) transitions from levels in the 2p4f configuration of N{sup +}. Electron correlation and relativistic effects, including the Breit interaction, were systematically taken into account within the framework of the multiconfiguration Dirac-Hartree-Fock method. Except for the 2p4f-2p4d transitions with quite large wavelengths and the two-electron-one-photon 2p4f-2s2p {sup 3} transitions, the uncertainties of the present calculations were controlled to within 3% and 5% for wavelengths and oscillator strengths, respectively. We also compared our results with other theoretical and experimental values when available. Discrepancies were found between our calculations and previous calculations due to the neglect of relativistic effects in the latter.

79 ASTRONOMY AND ASTROPHYSICS↗

Observations of xenon spectra on the EAST x-ray crystal spectrometer for high-temperature plasma diagnostics

The Xe 44+ 2.7203 Å line, which has been proposed as one of the diagnostic lines for the x-ray imaging crystal spectrometer on ITER, is observed on the EAST tokamak together with its several satellite lines. The observations are made under high electron temperature (T e ) conditions (core T e > 5 keV). Most of the observed xenon lines are identified by comparing the experiment results with the atomic simulation results. The first ion temperature measurements made by the xenon spectra on EAST are also reported in this article. These xenon spectra observations contribute to the justification for using xenon as the diagnostic impurity in x-ray crystal spectrometers in future reactor-scale high-temperature plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PLASMA DIAGNOSTICS OF AN EIT WAVE OBSERVED BY HINODE/EIS AND SDO/AIA

We present plasma diagnostics of an Extreme-Ultraviolet Imaging Telescope (EIT) wave observed with high cadence in Hinode/Extreme-Ultraviolet Imaging Spectrometer (EIS) sit-and-stare spectroscopy and Solar Dynamics Observatory/Atmospheric Imaging Assembly imagery obtained during the HOP-180 observing campaign on 2011 February 16. At the propagating EIT wave front, we observe downward plasma flows in the EIS Fe XII, Fe XIII, and Fe XVI spectral lines (log T Almost-Equal-To 6.1-6.4) with line-of-sight (LOS) velocities up to 20 km s{sup -1}. These redshifts are followed by blueshifts with upward velocities up to -5 km s{sup -1} indicating relaxation of the plasma behind the wave front. During the wave evolution, the downward velocity pulse steepens from a few km s{sup -1} up to 20 km s{sup -1} and subsequently decays, correlated with the relative changes of the line intensities. The expected increase of the plasma densities at the EIT wave front estimated from the observed intensity increase lies within the noise level of our density diagnostics from EIS Fe XIII 202/203 A line ratios. No significant LOS plasma motions are observed in the He II line, suggesting that the wave pulse was not strong enough to perturb the underlying chromosphere. This is consistent with the finding that no H{alpha} Moreton wave was associated with the event. The EIT wave propagating along the EIS slit reveals a strong deceleration of a Almost-Equal-To -540 m s{sup -2} and a start velocity of v{sub 0} Almost-Equal-To 590 km s{sup -1}. These findings are consistent with the passage of a coronal fast-mode MHD wave, pushing the plasma downward and compressing it at the coronal base.

79 ASTRONOMY AND ASTROPHYSICS↗

Laser power meters as an X-ray power diagnostic for LCLS-II

For the LCLS-II X-ray instruments, laser power meters are being developed as compact X-ray power diagnostics to operate at soft and tender X-ray photon energies. These diagnostics can be installed at various locations along an X-ray free-electron laser (FEL) beamline in order to monitor the transmission of X-ray optics along the beam path. In addition, the power meters will be used to determine the absolute X-ray power at the endstations. Here, thermopile power meters, which measure average power, and have been chosen primarily for their compatibility with the high repetition rates at LCLS-II, are evaluated. Here, a number of characteristics in the soft X-ray range are presented including linearity, calibrations conducted with a photodiode and a gas monitor detector as well as ultra-high-vacuum compatibility tests using residual gas analysis. The application of these power meters for LCLS-II and other X-ray FEL sources is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fluorescence intensity monitors as intensity and beam-position diagnostics for X-ray free-electron lasers

For LCLS-II, a fluorescence intensity monitor for the non-invasive, pulse-by-pulse normalization of experiments has been developed. A prototype diagnostic was constructed with a microchannel plate assembly and two photodiodes. The diagnostic was then installed in the LCLS SXR instrument Kirkpatrick–Baez mirror chamber with the detectors located above the vertically reflecting mirror. The linearity, noise and position sensitivity of the detectors have been characterized. The photodiode responsivity is suitable for high pulse energies. The microchannel plate detector shows sufficient responsivity over a wide range of pulse energies. The relative signal from the two photodiodes provides a sensitive measure of the X-ray beam position. The fluorescence intensity monitor provides intensity normalization while being compatible with high incident power, a 0.93 MHz repetition rate and ultra-high vacuum.

47 OTHER INSTRUMENTATION↗

Photon diagnostics at the FLASH THz beamline

The THz beamline at FLASH, DESY, provides both tunable (1–300 THz) narrow-bandwidth (∼10%) and broad-bandwidth intense (up to 150 uJ) THz pulses delivered in 1 MHz bursts and naturally synchronized with free-electron laser X-ray pulses. Combination of these pulses, along with the auxiliary NIR and VIS ultrashort lasers, supports a plethora of dynamic investigations in physics, material science and biology. The unique features of the FLASH THz pulses and the accelerator source, however, bring along a set of challenges in the diagnostics of their key parameters: pulse energy, spectral, temporal and spatial profiles. Here, these challenges are discussed and the pulse diagnostic tools developed at FLASH are presented. In particular, a radiometric power measurement is presented that enables the derivation of the average pulse energy within a pulse burst across the spectral range, jitter-corrected electro-optical sampling for the full spectro-temporal pulse characterization, spatial beam profiling along the beam transport line and at the sample, and a lamellar grating based Fourier transform infrared spectrometer for the on-line assessment of the average THz pulse spectra. Corresponding measurement results provide a comprehensive insight into the THz beamline capabilities.

47 OTHER INSTRUMENTATION↗

Advances in Optical Fiber-Based Faraday Rotation Diagnostics

In the past two years, we have used optical fiber-based Faraday Rotation Diagnostics (FRDs) to measure pulsed currents on several dozen capacitively driven and explosively driven pulsed power experiments. We have made simplifications to the necessary hardware for quadrature-encoded polarization analysis, including development of an all-fiber analysis scheme. We have developed a numerical model that is useful for predicting and quantifying deviations from the ideal diagnostic response. We have developed a method of analyzing quadrature-encoded FRD data that is simple to perform and offers numerous advantages over several existing methods. When comparison has been possible, we have seen good agreement with our FRDs and other current sensors.

42 ENGINEERING↗

Progress on the Design Development for Hard Core Components for USDA Diagnostics at ITER

An ITER hard core component (HCC) is defined for each undesirable situation with cliff edge effect consequences. Such structure system components (SCCs) are designed to prevent these situations at nuclear power plants, as well as to return and maintain a safe state in the event such a situation occurs. Only two hard core situations can really lead to cliff edge effect unless HCCs are implemented to limit the consequences: extreme earthquake (SL-3) and multiples fire in tritium building initiated by SL-3. The equipment (window and/or shutter) that closes penetrations from both sides of gallery to outside (Diagnostic building, Tritium building, and Assembly building) are classified as HCCs and SIC-2. Furthermore, design status of the HCC penetrations belong to US ITER diagnostic systems will be presented in this publication.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗