Impact of particle loading and phase coupling on gas–solid flow dynamics: A case study of a two-phase, gas–solid flow in an annular pipe

The present study is devoted to a two-phase, gas–solid flow in an annular pipe (hollow cylinder) at an elevated pressure of 15 bars and moderate Reynolds number of circa 6000. The influence of the particle loading, the interaction between the phases, and turbulence dispersion on the flow dynamics is systematically studied by means of computational fluid dynamics simulations, employing the Ansys FLUENT commercial package. The cases with a particle volumetric fraction of 1.2% are referred to as “high particle loading,” and those with 0.13% are denoted as “low particle loading.” The following cases are investigated: (1) pure gas flow; (2) low particle loading two-phase flow with one-way coupling and with turbulence dispersion; (3) low particle loading two-phase flow with two-way coupling but without turbulence dispersion; (4) low particle loading two-phase flow with two-way coupling and with turbulence dispersion; (5) high particle loading two-phase flow with one-way coupling and with turbulence dispersion; (6) high particle loading two-phase flow with two-way coupling but without turbulence dispersion; and (7) high particle loading two-phase flow with two-way coupling and with turbulence dispersion. Additionally, the boundary layer is found to grow without fluctuations of the turbulent kinetic energy (TKE) for cases 1, 2, and 5. For case 4, the TKE fluctuations have been identified, although they appear to be less substantial than those in cases 6 and 7. The authors attribute the semi-chaotic nature of the TKE fluctuations to the particle loading and two-way coupling. In addition, the onset and development of the flow instability have been observed at a random axial distance in cases 4, 6, and 7. Such instability is also attributed to the two-way coupling with turbulence dispersion in the flow. It is concluded that the particle loading, one-way, or two-way coupling between the phases, and the turbulence dispersion models significantly influence the development of the flow dynamics with the same inlet and boundary conditions. Consequently, it is not a trivial question, which result a user should trust. The present computational results inspire to perform verification as well as experimental validation of the simulations, so the simulation results can subsequently be used with confidence for design analysis.

42 ENGINEERING↗

Chain and Segmental Dynamics in Polymer–Nanoparticle Composites with High Nanoparticle Loading

Recent experimental and simulation studies have shown that polymer–nanoparticle (NP) composites (PNCs) with ultra-high NP loading (>50%) exhibit remarkable mechanical properties and dramatic increases in polymer glass-transition temperature, viscosity, and thermal stability compared to the bulk polymer. These deviations in macroscopic properties suggest a slowdown in both segmental and chain-scale polymer dynamics due to confinement. In this work, we examine the polymer conformations and dynamics in these PNCs using molecular dynamics simulations of both unentangled and entangled coarse-grained polymers in random-close-packed NP packings with varying polymer fill fractions. We find that the changes in the polymer dynamics depend on the number of NPs in contact with a polymer segment. Using the number of polymer–NP contacts and different polymer chain conformations as criteria for categorization, we further examine the polymer dynamics at multiple length scales to show the high level of dynamic heterogeneity in PNCs with ultra-high NP loading.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing Microplasticity in Small-Scale FCC Crystals via Dynamic Mechanical Analysis

In small-scale metallic systems, collective dislocation activity has been correlated with size effects in strength and with a steplike plastic response under uniaxial compression and tension. Yielding and plastic flow in these samples is often accompanied by the emergence of multiple dislocation avalanches. Dislocations might be active preyield, but their activity typically cannot be discerned because of the inherent instrumental noise in detecting equipment. We apply alternate current load perturbations via dynamic mechanical analysis during quasistatic uniaxial compression experiments on single crystalline Cu nanopillars with diameters of 500 nm and compute dynamic moduli at frequencies 0.1, 0.3, 1, and 10 Hz under progressively higher static loads until yielding. By tracking the collective aspects of the oscillatory stress-strain-time series in multiple samples, we observe an evolving dissipative component of the dislocation network response that signifies the transition from elastic behavior to dislocation avalanches in the globally preyield regime. We postulate that microplasticity, which is associated with the combination of dislocation avalanches and slow viscoplastic relaxations, is the cause of the dependency of dynamic modulus on the driving rate and the quasistatic stress. We construct a continuum mesoscopic dislocation dynamics model to compute the frequency response of stress over strain and obtain a consistent agreement with experimental observations. The results of our experiments and simulations present a pathway to discern and quantify correlated dislocation activity in the preyield regime of deforming crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design of a Three-Layer Impactor for Material Strength Measurements at Multi-Megabar Pressures

Off-Hugoniot loading methods for dynamic compression have been a topic of interest for many years as a means of accessing high pressures without melting a material. Simulations and an initial test experiment of a three-layer gas-gun impactor suitable for use in measuring dynamic material strength at multi-megabar pressures are described. As shown through ARES hydrocode simulations, an impactor consisting of a low-, medium-, and high-impedance material, such as TPX, Al, and Ta or Pt, can produce a quasi-isentropic loading path up to 4.6 Mbar pressure with a low homologous temperature (T/T melt = 0.1–0.25). These impactors can also be tailored to create a pressure drive suitable for a Lagrangian sound speed experiment. Simulated in-situ velocities were analyzed to determine the change in calculated strength due to non-uniformity in the impactor, which provides a measure of error sensitivity. An initial test of a three-layer projectile onto a flat target at 4.4 km/s impact velocity is reported. Finally, while the impactor incurred some delamination during firing, the measured sample/window interface velocity generally agrees with the simulated peak velocity and subsequent release, indicating the feasibility of this approach for measuring material strength.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Examining Uncertainty in Demand Response Baseline Models and Variability in Automated Response to Dynamic Pricing

Controlling electric loads to deliver power system services presents a number of interesting challenges. For example, changes in electricity consumption of Commercial and Industrial (C&I) facilities are usually estimated using counterfactual baseline models, and model uncertainty makes it difficult to precisely quantify control responsiveness. Moreover, C&I facilities exhibit variability in their response. This paper seeks to understand baseline model error and demand-side variability in responses to open-loop control signals (i.e. dynamic prices). Using a regression-based baseline model, we define several Demand Response (DR) parameters, which characterize changes in electricity use on DR days, and then present a method for computing the error associated with DR parameter estimates. In addition to analyzing the magnitude of DR parameter error, we develop a metric to determine how much observed DR parameter variability is attributable to real event-to-event variability versus simply baseline model error. Using data from 38 C&I facilities that participated in an automated DR program in California, we find that DR parameter errors are large. For most facilities, observed DR parameter variability is likely explained by baseline model error, not real DR parameter variability; however, a number of facilities exhibit real DR parameter variability. In some cases, the aggregate population of C&I facilities exhibits real DR parameter variability, resulting in implications for the system operator with respect to both resource planning and system stability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wind Turbine Gust Load Alleviation with Active Flow Control

Large wind turbine rotors are becoming more common in utility-scale wind power, especially for offshore wind plants. However, the trend toward large rotors can be limited by their ability to manage dynamic and extreme loads. To provide a safety margin for the rotor design and avoid catastrophic events such as tower strikes, extreme loads need to be controlled. The objective of this study is to develop and evaluate a feedback control system to alleviate extreme loads and reduce blade deflections under gust events using active flow control devices. We also propose a modification in the turbine controller to achieve further reduction in extreme loads. The extreme load reductions are evaluated under gust wind conditions with direction changes according to the IEC standard. The effects of the gust alleviation controller on turbine performance and fatigue loads are investigated as well. With the deployment of the gust alleviation controller and modified turbine baseline controller, the extreme loads and deflections reduce by up to 23%. The energy captured by the turbine is not affected by the proposed gust alleviation controller. The fatigue loads of various wind turbine components are either reduced or remain unchanged.

17 WIND ENERGY↗

Reviewing flexibility in industrial electrification: Focusing on green ammonia and steel in the United States

The renewable energy transition in the power sector involves a paradigm shift for flexibility. Flexible demand is more attainable than before, while supply flexibility faces new constraints due to the increased share of variable renewable resources. Increased demand flexibility can allow less use of peaking power plants and avoid need for additional capacity. Industrial flexibility could be especially interesting in this regard, as industrial customers are larger on average than other customers and have typically provided the largest share of demand response in the United States. We consider industrial demand, studying characteristics of flexible industrial loads. We then examine the dynamics of change occurring around industrial load flexibility by focusing on two case studies: green ammonia and steel production via electric arc furnaces. Electric arc furnace steel production is an important component of current demand response programs, whereas green ammonia and green fuels offer new paradigms for flexibility. We analyze the structure and functions of the technological innovation systems of load flexibility in those two industries via interviews with twenty-two stakeholders. Here, we conclude that in the United States these technological innovation systems are not well-functioning for industry in general or for steel, but do seem to be present for green ammonia. Additionally, explicit connections between scope two greenhouse gas emissions (those from purchased energy) and flexibility are lacking, and likewise industry stakeholders do not appear to make a connection between decarbonization and load flexibility, thus flexible demand is not viewed as a tool in industrial decarbonization.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Technology Solutions Case Study: Advanced Boiler Load Monitoring Controls, Chicago, Illinois

Most of Chicago’s older multifamily housing stock is heated by centrally metered steam or hydronic systems. The cost of heat is typically absorbed into the owner’s operating cost and is then passed to tenants. Central boilers typically have long service lifetimes; the incentive for retrofit system efficiency upgrades is greater than equipment replacement for the efficiency-minded owner. System improvements as the “low-hanging fruit” are familiar, from improved pipe insulation to aftermarket controls such as outdoor temperature reset (OTR) or lead/lag controllers for sites with multiple boilers. Beyond these initial system efficiency upgrades are an emerging class of Advanced Load Monitoring (ALM) aftermarket controllers that dynamically respond to the boiler load, with claims of 10% to 30% of fuel savings over a heating season. In this project, the Building America team Partnership for Advanced Residential Retrofit (PARR) installed and monitored an ALM aftermarket controller, the M2G from Greffen Systems, at two Chicago area multifamily buildings with existing OTR control. Results show that energy savings depend on the degree to which boilers are oversized for their load, represented by cycling rates. Also, savings vary over the heating season with cycling rates, with greater savings observed in shoulder months. Over the monitoring period, oversized boilers at one site showed reductions in cycling and energy consumption in line with prior laboratory studies, while less oversized boilers at another site showed muted savings.

Building America↗

THERMAL MODELING OF HANFORD CESIUM AND STRONTIUM CANISTERS DURING SIMULATED LOADING

A computational fluid dynamics (CFD) model was built to simulate planned testing of heater assemblies within a canister and overpack for the Hanford Lead Canister (HLC) project. The HLC is a canister storage system that will contain heaters to simulate the decay heat of nuclear material and provide the canister storage system with environmental conditions equivalent to the operating conditions on a dry storage pad. The HLC will be equipped with long-term data collection and monitoring systems to provide an early warning of corrosion, pitting, cracking, or other signs of canister degradation that might threaten the integrity of the containment boundary over the potentially long term of dry storage. An important part of the HLC development is to make pretest numerical predictions for the behavior of the heated canister during the simulated radiolytic decay heat testing, which simulates the dry storage system during loading operations. The simulated radiolytic decay heat test is planned for mid-2024 in a configuration that includes the heater assembly, overpack, and canister, but with the lids removed to allow loading cesium and strontium capsules into the canister. One of the goals of the test is to evaluate the thermal behavior of the canister and overpack assembly in the ambient air of the test facility, which will provide data critical to validating the thermal models and understanding how the HLC will perform as a system once deployed. To best approximate real-world conditions, the CFD model includes the full air volume of the mock-up truck bay the heated canister test will be performed in, enabling detailed investigation of how the heated canister affects airflow around it. Rigorous pre-deployment testing of the complete HLC cask and canister system is intended to be completed before the HLC is deployed in the 2028 timeframe. This study presents the pre-test temperature predictions of the simulated radiolytic decay heat test. A description of the heater assembly, canister, and overpack system is presented. The model was developed with the commercial CFD software STAR-CCM+. An uncertainty analysis was run with the CFD model to determine the uncertainty in the temperature predictions and provide a range over which the predicted temperatures are expected to vary. The uncertainty analysis was preformed by coupling STAR-CCM+ with the software Dakota, which provides advanced parametric analyses, including quantification of margins and uncertainty with computational models. This work is expected to provide insight into SNF canister behavior.

Carpenter-Graffy, Dina E.↗

Dynamic Spatial and Temporal Structures on the Surface of Solids under Load

A model and a method are proposed to explain the origin and main specific features of the dynamic patterns of different types, which were previously observed on the free surface of solids under load in experiments. It is shown that the pattern is formed due to the dynamic instability of the flat surface of the solid under load. This instability develops at the relaxation mechanism caused by the dynamic atomic displacements due to a change in the interatomic interaction during the electron-density redistribution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Hybrid Demand Response Simulator Version 1.0

A hybrid demand response simulator is developed to test different control algorithms for centralized and distributed demand response (DR) programs in a small distribution power grid. The HDRS is designed to model a wide variety of DR services such as peak having, load shifting, arbitrage, spinning reserves, load following, regulation, emergency load shedding, etc. The HDRS does not model the dynamic behaviors of the loads, rather, it simulates the load scheduling and dispatch process. The load models include TCAs (water heaters, air conditioners, refrigerators, freezers, etc) and non-TCAs (lighting, washer, dishwasher, etc.) The ambient temperature changes, thermal resistance, capacitance, and the unit control logics can be modeled for TCA loads. The use patterns of the non-TCA can be modeled by probability of use and probabilistic durations. Some of the communication network characteristics, such as delays and errors, can also be modeled. Most importantly, because the simulator is modular and greatly simplified the thermal models for TCA loads, it is very easy and fast to be used to test and validate different control algorithms in a simulated environment.

Lu, Ning↗

Modeling of Inductive Constant Power Load for Electromagnetic-Transient Simulations-Part II

This paper improves the dynamic constant power (CP) load model that was published in Part I, which is appropriate for electromagnetic-transient (EMT). The improved model conserves all features of its predecessor. For instance, it maintains a fixed power consumption (both active and reactive parts) and a fixed power factor for loads that are predominantly inductive. Furthermore, as the proposed model is a time-dependent system, it is applicable to both sinusoidal and non-sinusoidal case studies. However, the previous model cannot be easily integrated with numeric solvers because it simulated load data over one cycle all together, not sequentially in a time-step manner, due to the limitation involved with the power factor. The improved version, on the contrary, allows the load to be simulated at every time step, which would facilitate its integration with numeric solvers. The model's validity is confirmed by comparing its response with data that is synthesized from constant impedance load, and the result is satisfactory.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Rate-dependent phase transition of high density polyethylene

Quasi-static and dynamic tension tests are conducted on a widely used semicrystalline polymer, high density polyethylene (HDPE), to explore the strain rate effects on phase transition. HDPE exhibits considerable strain-rate hardening. In situ , high-speed x-ray diffraction demonstrates a martensitic transformation from the orthorhombic to monoclinic phase during both loading conditions. However, compared to quasi-static loading, the phase transition occurs at a lower bulk strain but higher stress under dynamic loading (strain rate 5100 s –1 ), suggesting strain-rate-accelerated phase transition dynamics. Furthermore, evolutions of lattice strain with bulk stress indicate different roles of amorphous and crystalline phases in deformation under different strain rates.

36 MATERIALS SCIENCE↗

Dynamic Tensile Response of a Fe–49Co–2V Alloy at Various Strain Rates and Temperatures

Soft ferromagnetic alloys are often utilized in electromagnetic applications due to their desirable magnetic properties. In support of these applications, the ferromagnetic alloys are also required to bear mechanical load under various loading and environmental conditions. In this study, a Fe–49Co–2V alloy was dynamically characterized in tension with a Kolsky tension bar and a Drop–Hopkinson bar at various strain rates and temperatures. Dynamic tensile stress–strain curves of the Fe–49Co–2V alloy were obtained at strain rates ranging from 40 to 230 s -1 and temperatures from - 100 to 100 °C. All dynamic tensile stress–strain curves exhibited an initial linear elastic response to an upper yield followed by Lüders band response and then a nearly linear work-hardening behavior. The yield strength of this material was found to be sensitive to both strain rate and temperature, whereas the hardening rate was independent of strain rate or temperature. The Fe–49Co–2V alloy exhibited a feature of brittle fracture in tension under dynamic loading with no necking being observed.

36 MATERIALS SCIENCE↗

Integration of Retail and Wholesale Markets: Modeling Framework and Stability Analysis

As power systems cope with increasing amounts of renewable generation, there is an increasing need to engage flexible demand-side resources and distributed energy resources (DERs) into power systems operations. However engagine millions of DERs in a reliable manner into power systems operations can be a challenging problem. Retail markets can facilitate this by providing a platform to aggregate the flexibility of DERs and bid the aggregate flexibility into wholesale markets. However, unlike generators (which can typically be modeled accurately with capacity constraints and ramping limits), most flexible loads have physical dynamics (like air conditioners) that couples their flexibility over time. This coupling could have unintended undesirable consequences (for example, instability and oscillations in prices and other physical quantities). In this paper, we propose a simple model to capture evolution of load flexibility over time and analyze stability of the interconnection between wholesale and retail electricity markets. We prove that under a natural model of flexibility evolution (assuming a constant base load), oscillations cannot occur and prices converge to a unique equilibrium model quickly.

Ramachandran, Thiagarajan↗

Pre-Compressed Targets for Gas Gun Studies

This work developed the capability for pre-compressing targets for Hugoniot measurements utilizing gas gun driven flyer plates. Initial condition control, such as pre-compression, allows access to states off the principal Hugoniot and in the case of highly compressible materials, the locus of shock states may be well off (significantly denser than) the principal Hugoniot even for relatively modest (~100's MPa) initial pressures. The design and operation of the pre-compression target hardware will be discussed in relation to functionality and design considerations for dynamic testing. Capability for loading of super critical gases and gas mixtures has been successfully demonstrated and dynamic hypervelocity impacts of helium were tested. Example loading of supercritical alcohol (ethanol) will is presented in the context of previous impact studies of initially ambient quiescent liquid. Advantages and limitations of the system are discussed in the context accessing highly compressed states.