Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Low-temperature microwave characteristics of pseudomorphic In(x)Ga(1-x) As/In(0.52)Al(0.48)As modulation-doped field-effect transistors

Low-temperature microwave measurements of both lattice-matched and pseudomorphic In(x)Ga(1-x)As/In(0.48)As (x = 0.53, 0.60, and 0.70) channel MODFETs on InP substrates were carried out in a cryogenic measurement system. The measurements were done in the temperature range of 77 to 300 K and in the frequency range of 0.5 to 11.0 GHz at different bias conditions. The cutoff frequency (fT) for the In(x)Ga(1-x)As/In(0.52)Al(0.48)As MODFETs improved from 22 to 29 GHz, 29 to 38 GHz, and 39 to 51 GHz, for x = 0.53, 0.60, and 0.70, respectively, as the temperature was lowered from 300 to 77 K, which is approximately a 31 percent increase at each composition. No degradations were observed in device performance. These results indicate an excellent potential of the pseudomorphic devices at low temperatures.

Lai, R.↗

Resonance Raman mapping as a tool to monitor and manipulate Si nanocrystals in Si-SiO{sub 2} nanocomposite

Specially designed laser heating experiment along with Raman mapping on Si-SiO{sub 2} nanocomposites elucidates the contribution of core and surface/interface in the intermediate frequency range (511–514 cm{sup −1}) Si phonons. The contribution of core to surface/interface increases with the size of Si nanocrystal, which itself increases on laser irradiation. Further, it is found that resonance Raman is crucial to the observance of surface/interface phonons and wavelength dependent Raman mapping can be corroborated with band edges observed in absorption spectra. This understanding can be gainfully used to manipulate and characterize Si-SiO{sub 2} nanocomposite, simultaneously for photovoltaic device applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

AN ABSENCE OF X-RAY ACCRETION SHOCK INSTABILITY SIGNATURES IN TW HYDRAE

Gas accreting onto T Tauri stars should form shocks that are susceptible to the classical radiative shock instability. The instability should give rise to strong periodic modulation in the X-ray emission from the shock-heated plasma. Time series analysis of soft X-rays thought to arise predominantly in an accretion shock on the classical T Tauri star TW Hydrae reveals no periodic variations and a 99% confidence pulsed fraction limit of 5% over the frequency range 0.0001-6.81 Hz. We find no clear explanation for the absence of X-ray instability signatures, but suggest that existing one-dimensional models are too simple to explain the three-dimensional shock structure, or that preheating and deceleration of the accretion stream by the damping of magnetohydrodynamic waves excited either by the shock itself, or more deeply in the stellar envelope, could ameliorate the instability in the likely case of a sub-Alfvenic shock.

79 ASTRONOMY AND ASTROPHYSICS↗

Crystals with an Open Wave-Vector Surface: Peculiarities of Reflection and Possibilities of Designing Flat Lenses

The frequency dependence of the reflection coefficient of MgF{sub 2} crystal in the frequency range of 200-800 cm{sup -1} at different orientations of the optical axis has been investigated. The experimental data are compared with the calculation results. This comparison confirms that the wave vectors for the extraordinary wave have an open surface. This makes it possible to focus a divergent beam refracted at a flat boundary ori- ented perpendicularly to the optical crystal axis. The focusing effect of a plane-parallel MgF{sub 2} crystal plate is calculated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental observation of 3-D, impulsive reconnection events in a laboratory plasma

Fast, impulsive reconnection is commonly observed in laboratory, space, and astrophysical plasmas. In this work, impulsive, local, 3-D reconnection is identified for the first time in a laboratory current sheet. The two-fluid, impulsive reconnection events observed on the Magnetic Reconnection Experiment (MRX) [Yamada et al., Phys Plasmas 4, 1936 (1997)] cannot be explained by 2-D models and are therefore fundamentally three-dimensional. Several signatures of flux ropes are identified with these events; 3-D high current density regions with O-point structure form during a slow buildup period that precedes a fast disruption of the reconnecting current layer. The observed drop in the reconnection current and spike in the reconnection rate during the disruption are due to ejection of these flux ropes from the layer. Underscoring the 3-D nature of the events, strong out-of-plane gradients in both the density and reconnecting magnetic field are found to play a key role in this process. Electromagnetic fluctuations in the lower hybrid frequency range are observed to peak at the disruption time; however, they are not the key physics responsible for the impulsive phenomena observed. Important features of the disruption dynamics cannot be explained by an anomalous resistivity model. An important discrepancy in the layer width and force balance between the collisionless regime of MRX and kinetic simulations is also revisited. The wider layers observed in MRX may be due to the formation of flux ropes with a wide range of sizes; consistent with this hypothesis, flux rope signatures are observed down to the smallest scales resolved by the diagnostics. Finally, a 3-D two-fluid model is proposed to explain how the observed out-of-plane variation may lead to a localized region of enhanced reconnection that spreads in the direction of the out-of-plane electron flow, ejecting flux ropes from the layer in a 3-D manner.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultrasonic Phased Array Evaluations Of Implanted And In-Situ Grown Flaws In Cast Austenitic Stainless Steel Pressurizer Surge Line Piping

A set of circumferentially oriented thermal fatigue cracks (TFCs) were implanted into three cast austenitic stainless steel (CASS) pressurizer (PZR) surge-line specimen welds (pipe-to-elbow configuration) that were salvaged from a U.S. commercial nuclear power plant that had not been operated. Thus, these welds were fabricated using vintage CASS materials that were formed in the 1970s. Additionally, in-situ grown TFCs were placed in the adjacent CASS base material of one of these specimens. Ultrasonic phased-array responses from both types of flaws (implanted and in-situ grown) were analyzed for detection and characterization based on sizing and signal-to-noise determination. Multiple probes were employed covering the 0.8 to 2.0 MHz frequency range. To further validate the Pacific Northwest National Laboratory (PNNL) findings, an independent in-service inspection (ISI) supplier evaluated the flaws with their American Society of Mechanical Engineers (ASME) Code, Section XI, Appendix VIII-qualified procedure. The results obtained by PNNL personnel compared favorably to the ISI supplier results. All examined flaws were detected and sized within the ASME Code-allowable limits.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effect of Zr concentration on conductivity behavior of (1-x)PMN-xPZ ceramic: An impedance spectroscopy analysis

Impedance spectroscopy study was carried out on Pb[Mg{sub (1-x)/3}Nb{sub 2(1-x)/3}Zr{sub x}]O{sub 3} for x=0.10, 0.20, and 0.30 in the frequency range 100 Hz-1 MHz and temperature range 498-723 K. The activation energies obtained for the conduction increase with an increase in Zr{sup 4+} content. A significant decrease in the electrical conductivity was observed by an increase in Zr{sup 4+} substitution. The conduction mechanism in PMN-PZ is attributed to the migration of doubly ionized oxygen vacancies. These results are explained in terms of lowering the structural disorder in PMN by Zr{sup 4+} substitution.

36 MATERIALS SCIENCE↗

Lightweight graphene nanoplatelet/boron carbide composite with high EMI shielding effectiveness

Lightweight graphene nanoplatelet (GNP)/boron carbide (B{sub 4}C) composites were prepared and the effect of GNPs loading on the electromagnetic interference (EMI) shielding effectiveness (SE) has been evaluated in the X-band frequency range. Results have shown that the EMI SE of GNP/B{sub 4}C composite increases with increasing the GNPs loading. An EMI SE as high as 37 ∼ 39 dB has been achieved in composite with 5 vol% GNPs. The high EMI SE is mainly attributed to the high electrical conductivity, high dielectric loss as well as multiple reflections by aligned GNPs inside the composite. The GNP/B{sub 4}C composite is demonstrated to be promising candidate of high-temperature microwave EMI shielding material.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

ROTATIONAL SPECTROSCOPY OF THE CO-PARA-H{sub 2} MOLECULAR COMPLEX

The rotational spectrum of the CO-para-H{sub 2} van der Waals complex, produced using a molecular jet expansion, was observed with two different techniques: OROTRON intracavity millimeter-wave spectroscopy and pulsed Fourier transform microwave spectroscopy. Thirteen transitions in the frequency range from 80 to 130 GHz and two transitions in the 14 GHz region were measured and assigned, allowing for a precise determination of the corresponding energy level positions of CO-para-H{sub 2}. The data obtained enable further radio astronomical searches for this molecular complex and provide a sensitive test of the currently best available intermolecular potential energy surface for the CO-H{sub 2} system.

74 ATOMIC AND MOLECULAR PHYSICS↗

A Graphene-Based Terahertz Hot Electron Bolometer with Johnson Noise Readout

In this paper, we present the development of a graphene-based hot electron bolometer with Johnson noise readout. The bolometer is a graphene microbridge connected to a log spiral antenna by Au contact pads. The Fourier transform spectrometer measurement shows the bolometer has high coupling efficiency in the frequency range from 0.3 to 1.6 THz. Using 300/77 K blackbody loads, we measure an optical noise equivalent power of 5.6 × 10{sup −12} W/Hz{sup 0.5} at 3.0 K. To understand the thermal transport inside the graphene microbridge, we measure the bolometers with different microbridge lengths at different bath temperatures. We find that the thermal conductance due to electron diffusion is significant in the bolometers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-performance terahertz wave absorbers made of silicon-based metamaterials

Electromagnetic (EM) wave absorbers with high efficiency in different frequency bands have been extensively investigated for various applications. In this paper, we propose an ultra-broadband and polarization-insensitive terahertz metamaterial absorber based on a patterned lossy silicon substrate. Experimentally, a large absorption efficiency more than 95% in a frequency range of 0.9–2.5 THz was obtained up to a wave incident angle as large as 70°. Much broader absorption bandwidth and excellent oblique incidence absorption performance are numerically demonstrated. The underlying mechanisms due to the combination of a waveguide cavity mode and impedance-matched diffraction are analyzed in terms of the field patterns and the scattering features. The monolithic THz absorber proposed here may find important applications in EM energy harvesting systems such as THz barometer or biosensor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probing confined acoustic phonons in free standing small gold nanoparticles

Polarized and depolarized spectra from gold (Au) nanoparticles of different sizes are investigated in the small size range, between 3 and 7 nm, using low frequency Raman spectroscopy. Acoustic vibrations of the free-standing Au nanoparticles are demonstrated with frequencies ranging from 5 to 35 cm{sup -1}, opening the way to the development of the acoustic resonators. A blue shift in the phonon peaks along with the broadening is observed with a decrease in particle size. Comparison of the measured frequencies with vibrational dynamics calculation and an examination as from the transmission electron microscopy results ascertain that the low frequency phonon modes are due to acoustic phonon quantization. Our results show that the observed low frequency Raman scattering originates from the spherical (l = 0) and quadrupolar (l = 2) vibrations of the spheroidal mode due to plasmon mediated acoustic vibrations in Au nanoparticles.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optimization studies of the ITER low field side reflectometer

Microwave reflectometry will be used on ITER to measure the electron density profile, density fluctuations due to MHD/turbulence, ELM density transients, and as a L-H transition monitor. The ITER low field side (LFS) reflectometer system will measure both core and edge quantities using multiple antenna arrays spanning frequency ranges of 15-155 GHz for the O-mode system and 55-220 GHz for the X-mode system. Optimization studies using the GENRAY ray-tracing code have been done for edge and core measurements. The reflectometer launchers will utilize the HE11 mode launched from circular corrugated waveguide. The launched beams are assumed to be Gaussian with a beam waist diameter of 0.643 times the waveguide diameter. Optimum launcher size and placement are investigated by computing the antenna coupling between launchers, assuming the launched and received beams have a Gaussian beam pattern.

47 OTHER INSTRUMENTATION↗

Normal State Charge Dynamics of Fe1.06Te0.88S0.14 Superconductor Probed with Infrared Spectroscopy

We have used optical spectroscopy to probe the normal state electrodynamic response of Fe{sub 1.06}Te{sub 0.88}S{sub 0.14}, a member of the 11 family of iron-based superconductors with T{sub c} = 8 K. Measurements have been conducted over a wide frequency range (50-50,000 cm{sup -1}) at selected temperatures between 10 and 300 K. At low temperatures the material behaves as an 'incoherent metal: a Drude-type peak is absent from the optical conductivity and all optical functions reveal that quasiparticles are not well defined down to the lowest measured temperature. We introduce 'generalized spectral weight' analysis and use it to track temperature induced redistribution of spectral weight. Our results, combined with previous reports, indicate that the 11 family of iron-based superconductors might be different from other families.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Instrumental noise estimates stabilize and quantify endothelial cell micro-impedance barrier function parameter estimates

A novel transcellular micro-impedance biosensor, referred to as the electric cell-substrate impedance sensor or ECIS, has become increasingly applied to the study and quantification of endothelial cell physiology. In principle, frequency dependent impedance measurements obtained from this sensor can be used to estimate the cell cell and cell matrix impedance components of endothelial cell barrier function based on simple geometric models. Few studies, however, have examined the numerical optimization of these barrier function parameters and established their error bounds. This study, therefore, illustrates the implementation of a multi-response Levenberg Marquardt algorithm that includes instrumental noise estimates and applies it to frequency dependent porcine pulmonary artery endothelial cell impedance measurements. The stability of cell cell, cell matrix and membrane impedance parameter estimates based on this approach is carefully examined, and several forms of parameter instability and refinement illustrated. Including frequency dependent noise variance estimates in the numerical optimization reduced the parameter value dependence on the frequency range of measured impedances. The increased stability provided by a multi-response non-linear fit over one-dimensional algorithms indicated that both real and imaginary data should be used in the parameter optimization. Error estimates based on single fits and Monte Carlo simulations showed that the model barrier parameters were often highly correlated with each other. Independently resolving the different parameters can, therefore, present a challenge to the experimentalist and demand the use of non-linear multivariate statistical methods when comparing different sets of parameters.

59 BASIC BIOLOGICAL SCIENCES↗

THz electrical instability of a hybrid system composed of quantum dot and quantum well with drifting electrons

We studied the hybrid system composed of a polarizable nanoparticle and a quantum well. For coupled oscillations of dipole excitations of the nanoparticle and two-dimensional electron gas, we determined frequencies and damping of the Landau-type. We found that under the drift of two-dimensional electrons, electrostatic coupling between the nanoparticle and the quantum well gives rise to a novel type of electrical instability in the terahertz frequency range. Under this electrical instability, amplitudes of the dipole and plasma oscillations increase in time due to the energy transfer from the drifting electrons. The instability arises when the electron drift velocity exceeds a critical value. Long relaxation times of the dipole excitations of the nanoparticle are favorable for development of the instability. We presented estimates, which demonstrate that the instability can be realized in quantum dot-quantum well hybrid systems fabricated by contemporary semiconductor technologies. This instability can provide a new mechanism for generation of THz radiation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observations of Langmuir ponderomotive effects using the Solar TErrestrial RElations Observatory spacecraft as a density probe

Langmuir ponderomotive effects are nonlinear effects that enable to couple the electron and ion dynamics in space plasmas. The main difficulty to provide observational evidence of such nonlinear coupling is to simultaneously observe both fluctuations of plasma density and electric field. We have thus developed a new method to measure and to calibrate in situ small scale density fluctuations. Density fluctuations in the solar wind are measured using the observed quasistatic fluctuations of the STEREO spacecraft floating potential in the frequency range, where the spacecraft floating potential is in quasistatic equilibrium between photoionization and electron attachment, whereas the potential of the antenna, of much longer equilibrium time scale, is blind to the density fluctuations. Density fluctuations and Langmuir waves are thus directly and simultaneously measured using a dataset of more than three years of STEREO/WAVES measurements. We present here the first observational evidence for ponderomotive effects in the solar wind that nonlinearly couple density fluctuations to high energy Langmuir waves (({epsilon}{sub 0}E{sup 2})/(nk{sub B}T)>10{sup -4}).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization of relativistic backward wave oscillator with non-uniform slow wave structure and a resonant reflector

This letter optimizes synchronously 18 parameters of a relativistic backward wave oscillator with non-uniform slow wave structure (SWS) and a resonant reflector by using the parallel genetic algorithms and particle-in-cell simulation. The optimization results show that the generation efficiency of microwave from the electron beam has increased 32% compared to that of the original device. After optimization, the electromagnetic mode propagating in the resonant changes from the original TM{sub 020} mode of reflector to higher-order TM{sub 021} mode, which has a high reflection coefficient in a broader frequency range than that of the former. The modulation of current inside the optimized device is much deeper than that in the original one. The product of the electric field and current is defined. Observing this product, it is found that the interaction of the electron beam with the electromagnetic wave in the optimized device is much stronger than that in the original device, and at the rear part of SWS of the optimized device, the electron beam dominantly gives out the energy to the electromagnetic wave, leading to the higher generation efficiency of microwave than that of the original device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗