SEARCH · Search NASA
Results for “graphite modeling”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Non-thermal structural transformation of diamond driven by x-rays
Intense x-ray pulses can cause the non-thermal structural transformation of diamond. At the SACLA XFEL facility, pump x-ray pulses triggered this phase transition, and probe x-ray pulses produced diffraction patterns. Time delays were observed from 0 to 250 fs, and the x-ray dose varied from 0.9 to 8.0 eV/atom. The intensity of the (111), (220), and (311) diffraction peaks decreased with time, indicating a disordering of the crystal lattice. From a Debye–Waller analysis, the rms atomic displacements perpendicular to the (111) planes were observed to be significantly larger than those perpendicular to the (220) or (311) planes. At a long time delay of 33 ms, graphite (002) diffraction indicates that graphitization did occur above a threshold dose of 1.2 eV/atom. These experimental results are in qualitative agreement with XTANT+ simulations using a hybrid model based on density-functional tight-binding molecular dynamics.
Characterization of runaway electron impact on instrumented sacrificial limiters on DIII-D
Instrumented sacrificial limiter heads, both domed (proud) and flat (flush) are used in DIII-D runaway electron (RE) wall strikes to study the wall impact dynamics with high spatial and time resolution. The approximate structure of the RE wetted area and heating depth on the domed limiter heads were predicted qualitatively using orbit-tracking simulations, although a strong left–right asymmetry (about the magnetic field direction) was not captured well by the simulations. It is hypothesized that this difference is perhaps due to the local 3D magnetic field perturbation of the dome limiter head. The average kinetic energy K and pitch angle θ of REs striking the limiter head were estimated from the spatial distribution of local HXR emission and were estimated to be roughly K ≈ 4 MeV and θ ≈ 0.2 rad. These values are roughly consistent with in-plasma values estimated before the loss event, indicating that RE kinetic energy and pitch angle are not drastically altered when transporting to the wall. Large shot–shot variations (1–10 kJ) in energy deposition into the limiter head were observed and were explained by shot–shot variations in locked magneto-hydrodynamics mode toroidal phase. For the largest deposited energies (10 kJ), graphite material failure and explosive dust release was observed, and the depth of material failure at higher energy deposition was successfully reproduced using modelling of volumetric energy deposition and brittle failure. The presence of energetic (keV) level ion impact during the RE wall strike was confirmed by three different surface analysis techniques. The ratio of energetic ion to RE flux appears to be larger on flat surfaces within the RE wetted area, although the energetic ion flux and total energy flux due to energetic ions have not yet been quantified.
Four-Wave-Mixing Approach to In Situ Detection of Nanoparticles
Here, we report on the development and experimental validation of a laser-based technique which uses coherent Rayleigh-Brillouin scattering (CRBS) to detect nanoparticles with characteristic sizes ranging from the atomic scale to tens of nanometers. This technique is aimed (nonexclusively) at the detection of nanoparticles produced by volumetric nanoparticle synthesis methods. Using CRBS, carbon nanoparticles of dimensions less than 10 nm and concentrations of 10 10 cm –3 are detected in situ in a carbon arc discharge with graphite electrodes. This four-wave-mixing approach should enable advances in the understanding of nanoparticle growth that could potentially lead to improved modeling of the growth mechanisms, and thus to improve synthesis selectivity of nanoparticles and yield.
Investigation of Structure and Reactivity Relationship in M-N-C Type Catalysts using Density Functional Tight Binding
Catalysts inhibition studies were performed to indisputably confirm the role of various metal, carbon, and nitrogen moieties in the individual steps of oxygen reduction reaction (ORR) on M-N-C catalysts. ORR activity was studied at University of New Mexico by rotating ring disk electrode method in the acidic electrolyte with the addition of Tris (tris(hydroxymethyl)-aminomethane) as inhibiting agent. To understand the interaction of Tris with different defects that exist in Fe-N-C materials and provide the support for the experimental data, we used density functional theory (DFT) and modeled the interaction of protonated Tris (TrisH) with Fe containingcenters (Fe-N 4 and Fe-N 2 C 2 ), pyridinic nitrogen, graphitic nitrogen, and pyrrolic nitrogen both as in plane and edge defects.
Design and fabrication of composite wing panels containing a production splice
Bolted specimens representative of both upper and lower wing surface splices of a transport aircraft were designed and manufactured for static and random load tension and compression fatigue testing including ground-air-ground load reversals. The specimens were fabricated with graphite-epoxy composite material. Multiple tests were conducted at various load levels and the results were used as input to a statistical wearout model. The statically designed specimens performed very well under highly magnified fatigue loadings. Two large panels, one tension and compression, were fabricated for testing by NASA-LRC.
Analytical prediction of moisture absorption/desorption in resin matrix composites exposed to aircraft environments
The moisture absorption/desorption behavior of resin matrix composites was mathematically modeled by classical diffusion theory using an effective diffusion coefficient. Good agreement was found between calculated moisture content and published data for T300/5208 graphite fiber reinforced epoxy matrix composite. Weather Bureau data for Langley Air Force Base and Norfolk, Va., were used to calculate the amount of moisture a T300/5208 composite panel would contain if exposed outdoors. Results obtained by using average monthly weather data for several high aircraft usage locations around the world suggest that, except for desert areas, geographical locations should have only minimal effect on the moisture absorption level reached in composites. Solar radiation data together with cloud and wind information were included in the analysis to estimate an effective temperature of the composite panel during ground exposure.
LSSA large area silicon sheet task continuous Czochralski process development
A Czochralski crystal growing furnace was converted to a continuous growth facility by installation of a premelter to provide molten silicon flow into the primary crucible. The basic furnace is operational and several trial crystals were grown in the batch mode. Numerous premelter configurations were tested both in laboratory-scale equipment as well as in the actual furnace. The best arrangement tested to date is a vertical, cylindrical graphite heater containing small fused silicon test tube liner in which the incoming silicon is melted and flows into the primary crucible. Economic modeling of the continuous Czochralski process indicates that for 10 cm diameter crystal, 100 kg furnace runs of four or five crystals each are near-optimal. Costs tend to asymptote at the 100 kg level so little additional cost improvement occurs at larger runs. For these conditions, crystal cost in equivalent wafer area of around $20/sq m exclusive of polysilicon and slicing was obtained.
Interlaminar stress analysis at the skin-stiffener interface of a grid-stiffened composite panel
Results are presented of an analysis of the interlaminar stress components at the skin-wrap, skin-core, and wrap-core interfaces for an advanced-concept stiffened panel using a global/local finite element procedure. The procedure consists of a global model of two-dimensional shell elements that is used to design a grid-stiffened panel with blade-type stiffeners, a local model of three-dimensional solid elements that is used to compute interlaminar stress components, and a scheme devised to assign displacement boundary conditions for the local model that are derived from displacement and rotation data of a few nodes of the global model. The interlaminar stresses for this panel design were found to be well below typical tensile normal and shearing strengths of a graphite-epoxy material.
Dynamic Finite Element Predictions for Mars Sample Return Cellular Impact Test #4
The nonlinear finite element program MSC.Dytran was used to predict the impact pulse for (he drop test of an energy absorbing cellular structure. This pre-test simulation was performed to aid in the design of an energy absorbing concept for a highly reliable passive Earth Entry Vehicle (EEV) that will directly impact the Earth without a parachute. In addition, a goal of the simulation was to bound the acceleration pulse produced and delivered to the simulated space cargo container. EEV's are designed to return materials from asteroids, comets, or planets for laboratory analysis on Earth. The EEV concept uses an energy absorbing cellular structure designed to contain and limit the acceleration of space exploration samples during Earth impact. The spherical shaped cellular structure is composed of solid hexagonal and pentagonal foam-filled cells with hybrid graphite-epoxy/Kevlar cell walls. Space samples fit inside a smaller sphere at the enter of the EEV's cellular structure. The material models and failure criteria were varied to determine their effect on the resulting acceleration pulse. Pre-test analytical predictions using MSC.Dytran were compared with the test results obtained from impact test #4 using bungee accelerator located at the NASA Langley Research Center Impact Dynamics Research Facility. The material model used to represent the foam and the proper failure criteria for the cell walls were critical in predicting the impact loads of the cellular structure. It was determined that a FOAMI model for the foam and a 20% failure strain criteria for the cell walls gave an accurate prediction of the acceleration pulse for drop test #4.
Analysis of Graphite Reinforced Cementitious Composites
This paper describes analytical methods that can be used to determine the deflections and stresses in highly compliant graphite-reinforced cementitious composites. It is demonstrated that the standard transform section fails to provide accurate results when the elastic modulus ratio exceeds 20. So an alternate approach is formulated by using the rule of mixtures to determine a set of effective material properties for the composite. Tensile tests are conducted on composite samples to verify this approach; and, when the effective material properties are used to characterize the deflections of composite beams subject to pure bending, an excellent agreement is obtained. Laminated composite plate theory is also investigated as a means for analyzing even more complex composites, consisting of multiple graphite layers oriented in different directions. In this case, composite beams are analyzed by incorporating material properties established from tensile tests. Finite element modeling is used to verity the results and, considering the complexity of the samples, a very good agreement is obtained.
Meteorite Dunite Breccia MIL 03443: A Probable Crustal Cumulate Closely Related to Diogenites from the HED Parent Asteroid
There are numerous types of differentiated meteorites, but most represent either the crusts or cores of their parent asteroids. Ureilites, olivine-pyroxene-graphite rocks, are exceptions; they are mantle restites [1]. Dunite is expected to be a common mantle lithology in differentiated asteroids. In particular, models of the eucrite parent asteroid contain large volumes of dunite mantle [2-4]. Yet dunites are very rare among meteorites, and none are known associated with the howardite, eucrite, diogenite (HED) suite. Spectroscopic measurements of 4 Vesta, the probable HED parent asteroid, show one region with an olivine signature [5] although the surface is dominated by basaltic and orthopyroxenitic material equated with eucrites and diogenites [6]. One might expect that a small number of dunitic or olivine-rich meteorites might be delivered along with the HED suite. The 46 gram meteoritic dunite MIL 03443 (Fig. 1) was recovered from the Miller Range ice field of Antarctica. This meteorite was tentatively classified as a mesosiderite because large, dunitic clasts are found in this type of meteorite, but it was noted that MIL 03443 could represent a dunite sample of the HED suite [7]. Here I will present a preliminary petrologic study of two thin sections of this meteorite.
Stability margin analysis of the Holos-quad microreactor design
A simplified point model of the Holos-Quad microreactor is introduced. The model is based on the point kinetics equations coupled to three heat balance equations, representing the mean temperatures of the fuel particles, the graphite moderator and the helium coolant. The differential equations are converted to the frequency domain, enabling the construction of the closed-loop reactor transfer function. Using this function the stability margins of the core design is analyzed for various power levels. It is shown that the gain margins approaches infinity, demonstrating the stability of the reactor for all power levels. The phase margin at nominal power is about 60 degrees, however it shows a non-monotonous dependence on power, with minimal value obtained for about 10% of nominal power. As power level is further increased, the phase margin also increases, demonstrating the reactor becomes more stable. This behavior may be of high importance in load-follow scenarios, where the power level of the reactor changes with time. (authors)
Development of the TREAT M2 experiment as a transient benchmark
A transient benchmark based on the Transient Reactor Test Facility (TREAT) M2 Calibration experiment (M2-CAL) is under development. TREAT, at Idaho National Laboratory, is a graphite moderated air-cooled research reactor which has been used extensively for fuel material testing under extreme and accident conditions. Accurate benchmark models are a beneficial component in the operations, experimental planning, and development of TREAT. In this work, we present a transient benchmark model for the M2-CAL experiment core loading. The benchmark model incorporates the coupling between the Monte Carlo Code SERPENT and the computational fluid dynamics code OpenFOAM to capture the temperature feedback mechanism. The M2-CAL transient 2580 was simulated in this work. A pre-transient analysis was performed to determine the optimum core composition and conditions before the beginning of the transient. The analysis was validated against historic TREAT kinetic measurements and the worth of the transient rod T-2. The axial power distribution in the flux wire for the M2-CAL experiment was determined and contrasted with the experiment. The model was then used to simulate the M2-CAL transient 2580 experiment based on the reported pre-transient and transient conditions. Several transient observables were calculated and compared to the experiment. The model shows good agreement with the experimental power traces, period, and average increase of power at the power ramp (time > 7.8 s). Inverse point kinetics analysis was performed during the period of the power ramp for the model and the experiment based on that, the temperature feedback component was isolated and contrasted with the experimental feedback. (authors)
Phase change material-to-refrigerant heat exchangers: Experimental validation and uneven melting analysis
Thermal energy storage (TES) using phase change materials (PCMs) enables load shifting and reduces mismatches between the building's thermal demand and the heat pump (HP) system's thermal capacity. While most TES studies have focused on single-phase heat transfer fluids, PCM-to-refrigerant heat exchangers (PRHX), in which the refrigerant undergoes liquid-vapor phase change, remain largely underexplored. Here, to address this gap, this study systematically investigates a shell-and-tube PRHX operating as the condenser in an HP through experiments and simulations. A two-dimensional enthalpy-based finite-volume PRHX model was developed and validated against experimental data, including refrigerant and PCM temperature profiles, PRHX capacity, and system-level performance. Results show three characteristic stages: Stage I, the condenser temperature rapidly increases with PCM in the solid state absorbing sensible heat; Stage II, stable operation during PCM phase change; and Stage III, performance decline once part of the PCM becomes fully melted. Heat transfer analysis revealed that uneven PCM melting along the condenser length was driven primarily by variations in the refrigerant-side heat transfer coefficient, rather than local approach temperature differences. Further study demonstrated that minimizing refrigerant outlet subcooling led to more uniform PCM melting and extended Stages I and II by up to 89%. This paper provides a validated PRHX model, clarifies the mechanisms of uneven PCM melting, and highlights subcooling control as an effective strategy to improve TES performance in HP systems without requiring secondary loops.
Experiment-modeling studies comparing energy dissipation in the DIII-D SAS and SAS-VW divertors
Recent DIII-D experiments on Small Angle Slot (SAS) divertors have confirmed that a combination of divertor closure and target shaping can enhance cooling across the divertor target and increase energy dissipation, but with significant dependence on B T (toroidal magnetic field) direction. In these novel divertors, the roles of closure, target shaping, drifts, and scale lengths are all interconnected in optimizing dissipation, with the separatrix electron density n eSEP being the key parameter associated with the level of dissipation/detachment. After modifying the original flat-targeted graphite SAS to include a V shape with a tungsten coating on the outer side of the divertor (SAS-VW), matched series of discharges were run to compare to detailed SOLPS-ITER modeling. Experimentally, when run as designed with the outer strike point at the slot vertex, SAS-VW requires nearly identical n eSEP for detachment as the original SAS, with little difference in dissipation for the new geometry. This is in contrast to (1) earlier modeling predictions that a small change of the SAS geometry to a V shape should enhance dissipation at the same n eSEP for magnetic configurations having better H-mode access (ion B × ∇B drift directed into the divertor), and (2) despite the achievement of significantly higher (2-7x) neutral pressures and compression in the SAS-VW slot. Comparisons of experimental density scans to the most recent SOLPS-ITER modeling with ExB drifts show reasonable agreement for dissipation/detachment onset when using separatrix density as the independent parameter. In order to help understand the discrepancy in modeled vs actual performance for the new configuration, additional measurements varying gas injection location and impurity injection were undertaken. In-slot D 2 gas fueling is more effective (5–22 %) in promoting detachment, in accord with modeling. In-slot impurity injection (N 2 or Ne) can yield 30 % lower core Z eff and 15 % less confinement degradation after detachment compared to main chamber puffing, as well as relatively lower tungsten leakage from the divertor. Modeling can also reproduce the improved detachment seen as the strike point moves inboard of the slot vertex. While we can explain the effects of the most important parameters causing energy dissipation in these slot divertors, it remains that many aspects of their behavior cannot be accurately modeled using state-of-art codes such as SOLPS-ITER. This is of concern for future model-driven designs utilizing similar V-shaped geometries.
Combined experimental and numerical evaluation of a prototype nano-PCM enhanced wallboard
In the United States, forty-eight (48) percent of the residential end-use energy consumption is spent on space heating and air conditioning. Reducing envelope-generated heating and cooling loads through application of phase change material (PCM)-enhanced building envelopes can facilitate maximizing the energy efficiency of buildings. Combined experimental testing and numerical modeling of PCM-enhanced envelope components are two important aspects of the evaluation of their energy benefits. An innovative phase change material (nano-PCM) was developed with PCM encapsulated with expanded graphite (interconnected) nanosheets, which is highly conductive for enhanced thermal storage and energy distribution, and is shape-stable for convenient incorporation into lightweight building components. A wall with cellulose cavity insulation and prototype PCM-enhanced interior wallboards was built and tested in a natural exposure test (NET) facility in a hot-humid climate location. The test wall contained PCM wallboards and regular gypsum wallboard, for a side-by-side annual comparison study. Further, numerical modeling of the walls containing the nano-PCM wallboard was performed to determine its actual impact on wall-generated heating and cooling loads. The model was first validated using experimental data, and then used for annual simulations using Typical Meteorological Year (TMY3) weather data. This article presents the measured performance and numerical analysis evaluating the energy-saving potential of the nano-PCM-enhanced wallboard.
Polarity effects and apparent ion recombination in microionization chambers
Purpose: Microchambers demonstrate anomalous voltage-dependent polarity effects. Existing polarity and ion recombination correction factors do not account for these effects. As a result, many commercial microchamber models do not meet the specification of a reference-class ionization chamber as defined by the American Association of Physicists in Medicine. The purpose of this investigation is to determine the cause of these voltage-dependent polarity effects. Methods: A series of microchamber prototypes were produced to isolate the source of the voltage-dependent polarity effects. Parameters including ionization-chamber collecting-volume size, stem and cable irradiation, chamber assembly, contaminants, high-Z materials, and individual chamber components were investigated. Measurements were performed with electrodes coated with graphite to isolate electrode conductivity. Chamber response was measured as the potential bias of the guard electrode was altered with respect to the collecting electrode, through the integration of additional power supplies. Ionization chamber models were also simulated using COMSOL Multiphysics software to investigate the effect of a potential difference between electrodes on electric field lines and collecting volume definition. Results: Investigations with microchamber prototypes demonstrated that the significant source of the voltage-dependent polarity effects was a potential difference between the guard and collecting electrodes of the chambers. The voltage-dependent polarity effects for each prototype were primarily isolated to either the guard or collecting electrode. Polarity effects were reduced by coating the isolated electrode with a conductive layer of graphite. Polarity effects were increased by introducing a potential difference between the electrodes. COMSOL simulations further demonstrated that for a given potential difference between electrodes, the collecting volume of the chamber changed as the applied voltage was altered, producing voltage-dependent polarity effects in the chamber response. Ionization chamber measurements and COMSOL simulations demonstrated an inverse relationship between the chamber collecting volume size and the severity of voltage-dependent polarity effects on chamber response. The effect of a given potential difference on chamber polarity effects was roughly ten times greater for microchambers as compared to Farmer-type chambers. Stem and cable irradiations, chamber assembly, contaminants, and high-Z materials were not found to be a significant source of the voltage-dependent polarity effects. Conclusions: A potential difference between the guard and collecting electrodes was found to be the primary source of the voltage-dependent polarity effects demonstrated by microchambers. For a given potential difference between electrodes, the relative change in the collecting volume is smaller for larger-volume chambers, illustrating why these polarity effects are not seen in larger-volume chambers with similar guard and collecting electrode designs. Thus, for small-volume chambers, it is necessary to reduce the potential difference between the guard and collecting electrodes in order to reduce polarity effects for reference dosimetry measurements.