Search NASA⌕ Search

SEARCH · Search NASA

Results for “importance sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Surface Sampling Techniques for the Canister Deposition Field Demonstration

This report describes plans for dust sampling and analysis for the multi-year Canister Deposition Field Demonstration. The demonstration will use three commercial 32PTH2 NUHOMS welded stainless steel storage canisters, which will be stored at an ISFSI site in Advanced Horizontal Storage Modules. One canister will be unheated; the other two will have heaters to achieve canister surface temperatures that match, to the degree possible, spent nuclear fuel (SNF) loaded canisters with heat loads of 10 kW and 40 kW. Surface sampling campaigns will take place on a yearly or bi-yearly basis. The goal of the planned dust sampling and analysis is to determine important environmental parameters that impact the potential occurrence of stress corrosion cracking on SNF dry storage canisters. Specifically, the size, morphology, and composition of the deposited dust and salt particles will be quantified, as well as the soluble salt load per unit area and the rate of deposition, as a function of canister surface temperature, location, time, and orientation. Sampling locations on the canister surface will nominally include 25 locations, corresponding to 5 circumferential locations at each of the 5 longitudinal locations. At each sampling location, a 2x2 sampling grid (containing 4 sample cells) will be painted onto the metal surface. During each sampling campaign, two samples at each sampling location will be collected, in a specific routine to measure both periodic (yearly or bi-yearly) and cumulative deposition rates. For each sample, a wet and a dry sample will be collected. Wet samples will be analyzed to determine the composition of the soluble salt fraction and to estimate salt loading per unit area. Dry samples will be analyzed to assess particle size, morphology, mineralogy, and identity (e.g. for floral/faunal fragments). The data generated by this proposed sampling plan will provide detailed information on dust and salt aerosol deposits on spent nuclear fuel canister surfaces. The anticipated results include information regarding particle compositions, size distributions, and morphologies, in addition to particle deposition rates as a function of canister surface location, orientation, time, and temperature. The information gathered during the Canister Deposition Field Demonstration is critical for ongoing efforts to develop a detailed understanding of the potential for stress corrosion cracking on SNF dry storage canisters

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Probing viscoelastic surfaces with bimodal tapping-mode atomic force microscopy: Underlying physics and observables for a standard linear solid model

This paper presents computational simulations of single-mode and bimodal atomic force microscopy (AFM) with particular focus on the viscoelastic interactions occurring during tip–sample impact. The surface is modeled by using a standard linear solid model, which is the simplest system that can reproduce creep compliance and stress relaxation, which are fundamental behaviors exhibited by viscoelastic surfaces. The relaxation of the surface in combination with the complexities of bimodal tip–sample impacts gives rise to unique dynamic behaviors that have important consequences with regards to the acquisition of quantitative relationships between the sample properties and the AFM observables. The physics of the tip–sample interactions and its effect on the observables are illustrated and discussed, and a brief research outlook on viscoelasticity measurement with intermittent-contact AFM is provided.

36 MATERIALS SCIENCE↗

The Danish contribution to the European DEMOCOPHES project: A description of cadmium, cotinine and mercury levels in Danish mother-child pairs and the perspectives of supplementary sampling and measurements

Human biomonitoring (HBM) is an important tool, increasingly used for measuring true levels of the body burdens of environmental chemicals in the general population. In Europe, a harmonized HBM program was needed to open the possibility to compare levels across borders. To explore the prospect of a harmonized European HBM project, DEMOCOPHES (DEMOnstration of a study to COordinate and Perform Human biomonitoring on a European Scale) was completed in 17 European countries. The basic measurements performed in all implemented countries of DEMOCOPHES included cadmium, cotinine and phthalate metabolites in urine and mercury in hair. In the Danish participants, significant correlations between mothers and children for mercury in hair and cotinine in urine were found. Mercury in hair was further significantly associated with intake of fish and area of residence. Cadmium was positively associated with BMI in mothers and an association between cadmium and cotinine was also found. As expected high cotinine levels were found in smoking mothers. For both mercury and cadmium significantly higher concentrations were found in the mothers compared to their children. In Denmark, the DEMOCOPHES project was co-financed by the Danish ministries of health, environment and food safety. The co-financing ministries agreed to finance a number of supplementary measurements of substances of current toxicological, public and regulatory interest. This also included blood sampling from the participants. The collected urine and blood samples were analyzed for a range of other persistent and non-persistent environmental chemicals as well as two biomarkers of effect. The variety of supplementary measurements gives the researchers further information on the exposure status of the participants and creates a basis for valuable knowledge on the pattern of exposure to various chemicals. - Highlights: • Levels of cadmium, mercury and cotinine in the Danish subpopulation are comparable to levels in the total DEMOCOPHES population with mercury in hair above the European median. • Supplementary sample collection and measurements in Denmark gave valuable exposure information on a variety of other chemicals of current toxicological, public and regulatory interest, such as persistent organic pollutants. • It is highly valuable to obtain as much exposure information as possible once you have established the study cohort.

54 ENVIRONMENTAL SCIENCES↗

The effect of hardness on polymer-bonded pentaerythritol tetranitrate (PETN) explosive impact sensitivity

Handling sensitivity is an important property to assess when working with explosive samples and can be measured using a variety of tests, including drop-weight impact sensitivity. There exists a longstanding interest in the explosives community on the importance of measurable chemical, physical, and mechanical properties of explosives in impact sensitivity. However, most recent work in this area has explored chemical attributes rather than physical and mechanical properties of explosives. In this study, we measure hardness of explosive samples of pentaerythritol tetranitrate and Sylgard binder (XTX) during the curing process. The samples have been characterized for particle morphology through scanning electron microscopy and handling sensitivity through drop-weight impact testing. The relative importance of states of cure, methods of curing, morphology, and age of material are discussed. The data indicate that although there is a notable difference in morphology and mechanical properties for the samples as the polymer-bonded mixtures cure, the resulting changes to mechanical properties have a minimal effect on the sensitivity of the XTX.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Statistics of associations among IR galaxies

In the course of expanding the search of Kleinmann et. al. (1988) for distant, infrared-luminous objects, the authors noticed (as is often remarked) that a large number of infrared-selected galaxies have close neighbors or show merger characteristics (e.g., tidal tails, distorted disks). Because the sample size is large (567 infrared galaxies and 2182 field galaxies), this sample is ideal for statistically examining the importance of interactions among infrared galaxies. In particular, the authors compare the nearest-neighbor distribution and the two-point correlation function of their sample with that of a control sample of field galaxies.

Gallimore, Jack F.↗

The Lunar Sample Compendium

The Lunar Sample Compendium is a succinct summary of the data obtained from 40 years of study of Apollo and Luna samples of the Moon. Basic petrographic, chemical and age information is compiled, sample-by-sample, in the form of an advanced catalog in order to provide a basic description of each sample. The LSC can be found online using Google. The initial allocation of lunar samples was done sparingly, because it was realized that scientific techniques would improve over the years and new questions would be formulated. The LSC is important because it enables scientists to select samples within the context of the work that has already been done and facilitates better review of proposed allocations. It also provides back up material for public displays, captures information found only in abstracts, grey literature and curatorial databases and serves as a ready access to the now-vast scientific literature.

Meyer, Charles↗

Thermal Flux Maximization from a DD Neutron Generator

The University of Sharjah recently acquired a model DD-109.4M neutron generator from Adelphi Technology. The generator is moderated and has three neutron ports which are capable of providing fast and thermal neutrons. The neutron ports are plugged with polyethylene layers of different thickness in order to control the neutron flux at different regions in the port. Neutron Activation Analysis (NAA) is an important analysis technique to determine the amounts of isotopes in a sample at different concentrations. For many isotopes the ability to precisely determine their concentrations is enhanced by utilizing thermal neutrons in the activation process; where the capture cross section is greatest. It is thus important to subject the sample to the maximum thermal flux in order to minimize the time required to activate the sample and consequently extend the lifetime of the neutron generator. A detailed MCNP model of the neutron generator has been developed for the purpose of determining the moderator thickness required to maximize the thermal neutron flux in the neutron port. The maximization of the neutron flux must therefore take into account both the forward and backscattered neutrons reaching the sample. Also provided in this work is a mapping of the thermal flux at different moderator thicknesses in order to study the variation of the flux over the area of the sample. The developed model will be used as the basis for optimizing experiments and predicting their results. A study was performed to determine the moderator thickness needed to maximize the thermal neutron flux that can be obtained from a DD neutron generator. This has a significant role in the efficient utilization of the neutron generator. The maximum thermal neutron flux was found at approximately a 3.2 cm moderator thickness. The thermal neutron flux is resulting from both the directly moderated neutrons and the backscattered neutrons from the surrounding polyethylene. The results obtained in this work will be verified experimentally by irradiating samples at different moderator thickness and performing a neutron activation analysis for these samples. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Mass recovery methods for trichloroethylene in plant tissue.

Monitoring expenses form a significant fraction of the costs associated with remediation of contaminated soil and groundwater sites. A novel monitoring method that could result in significant cost savings is the use of plants as monitoring devices; previous work indicates that plant tissue samples, especially trunk (core) and branch samples, can be used to delineate soil and groundwater plumes at phytoremediation sites. An important factor in reducing the uncertainty associated with this sampling method is development of a technique to analyze, both consistently and accurately, the chemicals stored in plant tissue samples. The present research presents a simple, robust, and inexpensive technique to recover most of the contaminant in plant branch tissue, irrespective of the age or species of the plant. Trichloroethylene (TCE) was the chemical analyzed. A number of headspace and solvent extraction techniques in the literature were evaluated, including headspace extraction at different incubation times and temperatures and solvent extraction using hexane or hot methanol. Extraction using hot methanol was relatively fast, simple, and reliable; this method recovered more than 89% of the TCE present in branches of five different tree species.

10 SYNTHETIC FUELS↗

Primary differentiation in the early Earth: Nd and Sr isotopic evidence from diamondiferous eclogites for both old depleted and old enriched mantle, Yakutia, Siberia

Ancient, stable, continental cratons possess thick, subcontinental-lithospheric mantle 'keels' which favor particularly the emplacement of diamondiferous kimberlites and included peridotites and eclogites. These refractory mantle samples of the roots provide hard constraints on the theories of formation, growth, and evolution of these cratons. Xenoliths containing only primary garnet and clinopyroxene (eclogites), although rare in most kimberlites, can retain the geochemical signatures of their parent protoliths (e.g., subducted oceanic crust, ancient mantle) thus offering the opportunity to address mantle processes which may have taken place at earlier times in the Earth's history. In fact, it has been postulated that some eclogites are residues from the accretion of the early Earth. Nd and Sr isotopic data are presented which may be interpreted as evidence of an early (greater than 4 Ga) mantle differentiation event. The kimberlites of Yakutia are located both marginal and central to the Siberian craton, and a wide variety of xenoliths are present within them. The Siberian mantle samples have received little attention in the western world, largely because suitable suites of Yakutian samples have not been readily available. Importantly, there is evidence that metasomatism of the Siberian lithosphere has been considerably less intense or extensive than for the Kaapvaal craton. Therefore, it should be considerably easier to elicit the igneous/metamorphic histories of Siberian kimberlitic xenoliths. One of the notable features of the Siberian eclogites is the common appearance of diamonds, especially in the Mir and Udachnaya pipes. In all, eight eclogite samples (eight garnet separates and eight clinopyroxene separates) have been analyzed to date on the Udachnaya pipe, seven from our group.

Snyder, Gregory A.↗

Magnetic anisotropy and crystalline electric field effects in RRh{sub 4}B{sub 4} single crystals.

Research on polycrystalline RRh{sub 4}B{sub 4} samples has shown that crystalline electric field (CEF) effects play an important role in these compounds. The successful synthesis of single crystal samples of RRh{sub 4}B{sub 4} with R = Y, Sm, Gd, Tb, Dy, Ho, Er, Tm, and Lu has provided an opportunity to further investigate CEF effects in these materials. Magnetization and magnetic susceptibility measurements on the RRh{sub 4}B{sub 4} single crystals revealed strong magnetic anisotropy, and the experimental results could be described well by CEF calculations based on the parameters derived from an analysis of experimental data for ErRh{sub 4}B{sub 4} single crystals. The easy directions of magnetization of these compounds are consistent with the signs of the Stevens factor {alpha}J of the CEF Hamiltonian. A strong influence of magnetic anisotropy on superconductivity was also observed.

36 MATERIALS SCIENCE↗

Proceedings for the Workshop on Applied Nuclear Data Activities 2024

The Workshop for Applied Nuclear Data Activities (WANDA) is designed to increase communication among nuclear data (ND) users in multidisciplinary federal programs, ND producers, ND funders, and other ND experts. It also presents an opportunity to cross-pollinate ideas as well as introduce ND gaps identified by federal programs to ND experts and ND capabilities to the various federal ND users. WANDA 2024 included five technical sessions, three of which focused on Fusion Energy Sciences (FES)—FES Fusion Neutronics, FES Tritium Production, and FES Material Damage—and two stand-alone sessions—Isotopes and Targetry for Nuclear Data and Uncertainty Quantification. The FES sessions successfully brought new voices to the WANDA discussions, expanding the application space in which nuclear data are critical. FES programs need accurate nuclear data with realistic uncertainty quantification to properly estimate, for example, shielding, activation, tritium production, helium production, structural material integrity, and superconducting magnet operation. This includes a variety of projectile (neutrons, photons, charged particles) and target atoms. One of the action items common to all the FES sessions was a need to perform sensitivity studies to identify the prioritization of nuclear data needs. The Isotopes and Targetry session highlighted the many capabilities available to produce high-quality targets for nuclear data measurements, including 3D printing with spherical powders, combustion synthesis coupled with spin coating & electrospraying, inkjet printing, and isotopic doping. These new methods open doors for more accurate measurement, but it was also stressed that sample characterization following any method of fabrication is of the highest importance to accurately interpret nuclear data measurement results that used that sample. The Uncertainty Quantification (UQ) session was broken into two categories: nuclear data uncertainty quantification and the use of that uncertainty quantification. Thematic to the UQ session was the loss of information when going from nuclear data measurement, to evaluation, to evaluated file, and finally to neutron transport calculations. Current evaluated ND libraries typically only contain covariances, which assume that the probability distributions are Gaussian. Beyond being a simplified assumption for many evaluations, this can lead to negative values on many observables when attempting to sample the covariance. The covariance format, however, is very efficient in that a simple set of linear equations can transform uncertainty from parameters or cross sections to the application of interest. Focused collaboration is needed between nuclear data evaluators and nuclear data users to ensure that needs are being met.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Use of Transmission Electron Microscopy for Analysis of Aerosol Particles and Strategies for Imaging Fragile Particles

For over 25 years, transmission electron microscopy (TEM) has provided a method for the study of aerosol particles with sizes from below the optical diffraction limit to several microns, resolving the particles as well as smaller features. The wide use of this technique to study aerosol particles has contributed important insights about environmental aerosol particle samples and model atmospheric systems. TEM produces an image that is a 2D projection of aerosol particles that have been impacted onto grids and, through associated techniques and spectroscopies, can contribute additional information such as the determination of elemental composition, crystal structure, and 3D particle structures. Soot, mineral dust, and organic/inorganic particles have all been analyzed using TEM and spectroscopic techniques. TEM, however, has limitations that are important to understand when interpreting data including the ability of the electron beam to damage and thereby change the structure and shape of particles, especially in the case of particles composed of organic compounds and salts. In this paper, we concentrate on the breadth of studies that have used TEM as the primary analysis technique. Another focus is on common issues with TEM and cryogenic-TEM. Insights for new users on best practices for fragile particles, that is, particles that are easily susceptible to damage from the electron beam, with this technique are discussed. Tips for readers on interpreting and evaluating the quality and accuracy of TEM data in the literature are also provided and explained.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of spectral analysis techniques for randomly sampled velocimetry data

It is well known that velocimetry (LV) generates individual realization velocity data that are randomly or unevenly sampled in time. Spectral analysis of such data to obtain the turbulence spectra, and hence turbulence scales information, requires special techniques. The 'slotting' technique of Mayo et al, also described by Roberts and Ajmani, and the 'Direct Transform' method of Gaster and Roberts are well known in the LV community. The slotting technique is faster than the direct transform method in computation. There are practical limitations, however, as to how a high frequency and accurate estimate can be made for a given mean sampling rate. These high frequency estimates are important in obtaining the microscale information of turbulence structure. It was found from previous studies that reliable spectral estimates can be made up to about the mean sampling frequency (mean data rate) or less. If the data were evenly samples, the frequency range would be half the sampling frequency (i.e. up to Nyquist frequency); otherwise, aliasing problem would occur. The mean data rate and the sample size (total number of points) basically limit the frequency range. Also, there are large variabilities or errors associated with the high frequency estimates from randomly sampled signals. Roberts and Ajmani proposed certain pre-filtering techniques to reduce these variabilities, but at the cost of low frequency estimates. The prefiltering acts as a high-pass filter. Further, Shapiro and Silverman showed theoretically that, for Poisson sampled signals, it is possible to obtain alias-free spectral estimates far beyond the mean sampling frequency. But the question is, how far? During his tenure under 1993 NASA-ASEE Summer Faculty Fellowship Program, the author investigated from his studies on the spectral analysis techniques for randomly sampled signals that the spectral estimates can be enhanced or improved up to about 4-5 times the mean sampling frequency by using a suitable prefiltering technique. But, this increased bandwidth comes at the cost of the lower frequency estimates. The studies further showed that large data sets of the order of 100,000 points, or more, high data rates, and Poisson sampling are very crucial for obtaining reliable spectral estimates from randomly sampled data, such as LV data. Some of the results of the current study are presented.

Sree, Dave↗

Optimal structure and parameter learning of Ising models

Reconstruction of the structure and parameters of an Ising model from binary samples is a problem of practical importance in a variety of disciplines, ranging from statistical physics and computational biology to image processing and machine learning. The focus of the research community shifted toward developing universal reconstruction algorithms that are both computationally efficient and require the minimal amount of expensive data. Here, we introduce a new method, interaction screening, which accurately estimates model parameters using local optimization problems. The algorithm provably achieves perfect graph structure recovery with an information-theoretically optimal number of samples, notably in the low-temperature regime, which is known to be the hardest for learning. Here, the efficacy of interaction screening is assessed through extensive numerical tests on synthetic Ising models of various topologies with different types of interactions, as well as on real data produced by a D-Wave quantum computer. Finally, this study shows that the interaction screening method is an exact, tractable, and optimal technique that universally solves the inverse Ising problem.

97 MATHEMATICS AND COMPUTING↗

A Comparative Study of Layer Heating and Continuous Heating Methods on Prediction Accuracy of Residual Stresses in Selective Laser Melted Tube Samples

Thermal distortion and residual stresses are two important factors that affect the quality and reliability of steel parts manufactured by laser powder bed fusion (LPBF) processes. A cost-effective model for evaluation of those heat effects is needed to refine the manufacturing process and provides insights into the product design and heat treatment. In this study, the layer heating method and sophisticated track-layer scanning method were applied to simulate the thermo-mechanical response of IN625 tube parts built by LPBF. Based on the similarity of temperature field in each layer deposit, a swept mesh was constructed to perform the thermal analysis for top layer, with the rest of layers referring to the temperature by node number offsetting. A novel explicit finite element analysis code accelerated by graphics processing unit was used for the massive-element numerical analysis. The computational accuracy and efficiency of the layer heating and track-layer scanning methods were compared in detail. It is shown that layer heating method can efficiently capture the pattern of stress distribution with reasonable accuracy in stress magnitude. The grouped track-layer scanning method can predict the residual stress and strain more accurately at a higher cost (5 ~ 10×). The elastic strain distribution was compared with the measurement by X-ray diffraction, confirming the accuracy of residual stress prediction.

36 MATERIALS SCIENCE↗

Concepts for Environmental Radioactive Air Sampling and Monitoring

Environmental radioactive air sampling and monitoring is becoming increasingly important as regulatory agencies promulgate requirements for the measurement and quantification of radioactive contaminants. While researchers add to the growing body of knowledge in this area, events such as earthquakes and tsunamis demonstrate how nuclear systems can be compromised. The result is the need for adequate environmental monitoring to assure the public of their safety and to assist emergency workers in their response. Two forms of radioactive air monitoring include direct effluent measurements and environmental surveillance. This chapter presents basic concepts for direct effluent sampling and environmental surveillance of radioactive air emissions, including information on establishing the basis for sampling and/or monitoring, criteria for sampling media and sample analysis, reporting and compliance, and continual improvement.

emissions↗

DEVELOPMENT OF A TAMPER RESISTANT/INDICATING AEROSOL COLLECTION SYSTEM FOR ENVIRONMENTAL SAMPLING AT BULK HANDLING FACILITIES

Environmental sampling has become a key component of International Atomic Energy Agency (IAEA) safeguards approaches since its approval for use in 1996. Environmental sampling supports the IAEA's mission of drawing conclusions concerning the absence of undeclared nuclear material or nuclear activities in a Nation State. Swipe sampling is the most commonly used method for the collection of environmental samples from bulk handling facilities. However, augmenting swipe samples with an air monitoring system, which could continuously draw samples from the environment of bulk handling facilities, could improve the possibility of the detection of undeclared activities. Continuous sampling offers the opportunity to collect airborne materials before they settle onto surfaces which can be decontaminated, taken into existing duct work, filtered by plant ventilation, or escape via alternate pathways (i.e. drains, doors). Researchers at the Savannah River National Laboratory and Oak Ridge National Laboratory have been working to further develop an aerosol collection technology that could be installed at IAEA safeguarded bulk handling facilities. The addition of this technology may reduce the number of IAEA inspector visits required to effectively collect samples. The principal sample collection device is a patented Aerosol Contaminant Extractor (ACE) which utilizes electrostatic precipitation principles to deposit particulates onto selected substrates. Recent work has focused on comparing traditional swipe sampling to samples collected via an ACE system, and incorporating tamper resistant and tamper indicating (TRI) technologies into the ACE system. Development of a TRI-ACE system would allow collection of samples at uranium/plutonium bulk handling facilities in a manner that ensures sample integrity and could be an important addition to the international nuclear safeguards inspector's toolkit. This work was supported by the Next Generation Safeguards Initiative (NGSI), Office of Nonproliferation and International Security (NIS), National Nuclear Security Administration (NNSA).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Qualitative Headspace GCMS Analysis of Lunar Regolith and Volatile Simulant Mixtures

Introduction: Future Artemis missions aim to return the volatile-bearing samples collected near lunar polar craters. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving the integrity of returned samples and the science value those samples contain. The extent to which that preservation is possible, and the trade-offs preservation requires (e.g. monetary costs, sample volume limitations) all must be considered. Even less-than pristine volatile-bearing samples will be of tremendous value to the scientific community seeking to unravel the history of lunar surface volatiles and, more broadly, volatiles in the solar system. A sample collected on the lunar surface will experience at least five distinctive periods during which any changes here referred to as “alteration” will certainly occur at some scale: collection on the lunar surface; transportation back to Earth; long-term storage; curatorial processing; and allocation/distribution. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on returned volatile samples by working with high-fidelity volatile-containing regolith simulants, setting the foundation for the future of cold curation. This abstract is focused on gas-surface interactions between LCROSS volatiles and readily available lunar regolith simulants. Experiments involved analyzing differences in headspace gas composition for various combinations of volatile and regolith simulants using gas chromatography/mass spectrometry (GC/MS). Experimental Procedure: The volatile simulants were chosen based on the molecules detected during the LCROSS mission.1 Stock solutions of condensed lunar volatile analytes were: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. The regolith simulants used were primarily JSC-1A and NU-LHT-4M. Additional regolith simulant control studies were conducted with <150 μm sieved sand and KBr. A nested vial sample preparation approach separated the liquid stock solutions from the regolith, eliminating potential matrix effects between liquid and solid phases. Fifteen microliter aliquots of liquid volatile simulants were added to a 2 mL liquid GC vial and capped in atmosphere. An 18G needle punctured the 2 mL GC vial immediately before being transferred and sealed in a 20 mL GC vial containing 0-0.3 g of regolith simulant, see Figure 1. Separating the analytes ensures any changes observed in the total headspace gases is a result of gas-surface and/or gas-gas interactions. Equipment and Method: Initial GC/MS method development for the separation and identification of relevant headspace gases can be found in Amick, et al. 2023.2 The only hardware change is a different column: a TG-1701MS 30 m × 0.25 mm × 1.00 μm column. The vials were sampled at 10°C, room temperature (~25°C) and 50°C. Low temperature samples were kept in a chilled autosampler stage for at least 1 hour prior to sampling. High temperature samples were agitated at 50°C for 5 minutes immediately prior to injection onto the column. Headspace chromatograms were collected for each combination of temperature, regolith, and volatile simulant, including controls without one or both types of analytes, in triplicate. The chromatogram elution window for each analyte or significant atmospheric gas was identified using the peak mass spectrum cross-referenced with Figure 1.Picture of the nested vial set-up. a NIST MS library search. Each analyte peak was integrated after filtering the mass spectrum trace for the parent or most unique mass-to-charge ratio. For example, the mass-to-charge ratio used to identify, filter for, and integrate the carbon dioxide peak was centered around 44 m/z. Results: Figure 2 shows the integrated peak area for hydrogen sulfide in all combinations of regolith simulants, temperatures, and the addition of ammonia in methanol solution. Multiple repeat experiments with H2S and regolith simulants have confirmed hydrogen sulfide is removed from the headspace within 1 hour when exposed to JSC-1A, NU-LHT-4M and sand (not pictured). The consumption of H2S by lunar regolith simulants at different temperatures indicates surface chemistry will be an integral component in sample integrity and preservation. It is important to note that while the effect of surface chemistry on gaseous hydrogen sulfide is intriguing, further investigation into more chemically accurate regolith simulants is necessary and ongoing. The sulfur in hydrogen sulfide is in its most reduced state while off-the-shelf, terrestrially sourced JSC-1A and NU-LHT-4M are more oxidized than most lunar materials,3which likely leads to different oxidation-reduction reactions than would be expected in lunar regolith. Figure 3 shows the integrated peak area of carbon dioxide for each sample combination that contained ammonia in methanol solution. The addition of ammonia to the GC vials results in a consistent and reproducible decrease in carbon dioxide gas, even at 50°C. The effect became more pronounced when JSC-1A or NU-LHT-4M were present. This set of experiments demonstrated that the sample composition will affect the chemical and physical state of each component present. Future spectroscopic and microscopy experiments will be geared towards identifying the cause for the CO2(g) concentration decrease and the consumption of hydrogen sulfide. As cold and volatile curation scientists, this information provides necessary insight on how to appropriately handle and analyze volatile bearing returned samples, as well as predict the effect chemical composition has on the various sample phases we will analyze upon return to Earth. Unlike traditional curation of geologic materials, the molecules in a sample cannot be identified or processed using the naked eye or even an optical microscope. Volatile curation will require a combination of analytical techniques, including but not limited to highly sensitive gas and solid/condensed phase spectroscopy. This set of experiments has demonstrated the need for more detailed studies of volatile mixtures with mineralogically and geochemically analogous lunar regolith simulants to prepare for the curation of volatile-rich lunar samples from the south polar region of the Moon. References: [1] Colaprete, A., et al. (2010) Science, 330, (463-468). [2] Amick, C. L., et al.(2023) Houston, Texas, [3] Heiken, G. H., et al.(1991) (778-778)

Cecilia L Amick↗