Search NASA⌕ Search

SEARCH · Search NASA

Results for “intermittency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Screw Placement and Osteoplasty Under Computed Tomographic-Fluoroscopic Guidance in a Case of Advanced Metastatic Destruction of the Iliosacral Joint

We present a case of combined surgical screw placement and osteoplasty guided by computed tomography-fluoroscopy (CTF) in a 68-year-old man with unilateral osteolytic destruction and a pathological fracture of the iliosacral joint due to a metastasis from renal cell carcinoma. The patient experienced intractable lower back pain that was refractory to analgesia. After transarterial particle and coil embolization of the tumor-feeding vessels in the angiography unit, the procedure was performed under general anesthesia by an interdisciplinary team of interventional radiologists and trauma surgeons. Under intermittent single-shot CTF, two K wires were inserted into the left iliosacral joint from a lateral transiliac approach at the S1 level followed by two self-tapping surgical screws. Continuous CTF was used for monitoring of the subsequent polymethylmethacrylate injection through two vertebroplasty cannulas for further stabilization of the screw threads within the osteolytic sacral ala. Both the screw placement and cement injection were successful, with no complications occurring during or after the procedure. With additional nonsteroidal anti-inflammatory and opioid medication, the patient reported a marked decrease in his lower back pain and was able to move independently again at the 3-month follow-up assessment. In our patient with intolerable back pain due to tumor destruction and consequent pathological fracture of the iliosacral joint, CTF-guided iliosacral screw placement combined with osteoplasty was successful with respect to joint stabilization and a reduction in the need for analgesic therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Subintimal Angioplasty of Long Chronic Total Femoropopliteal Occlusions: Long-Term Outcomes, Predictors of Angiographic Restenosis, and Role of Stenting

Purpose: The purpose of this article is to report the results of a prospective single-center study analyzing the long-term clinical and angiographic outcomes of subintimal angioplasty (SIA) for the treatment of chronic total occlusions (CTOs) of the femoropopliteal artery. Materials and Methods: Patients with severe intermittent claudication or critical limb ischemia (CLI) were enrolled in the study. All lesions were treated with SIA and provisional stenting. Primary end points were technical success, patient survival, limb salvage, lesion primary patency, angiographic binary restenosis (>50%), and target lesion revascularization (TLR). Regular clinical and angiographic follow-up was set at 6 and 12 months and yearly thereafter. Study end points were calculated with life-table survival analysis. Proportional-hazards regression analysis with a Cox-model was applied to adjust for confounding factors of heterogeneity. Results: Between May 2004 and July 2009, 98 patients (105 limbs, patient age 69.3 {+-} 9.9 years) were included in the study. Technical success rate was 91.4% with a lesion length of 121 {+-} 77 mm. Limb-salvage and survival rates were 88.7% and 84.1% at 3 years, respectively. After 12, 24, and 36 months, primary patency was 80.1%, 42.3%, and 29.0%, angiographic binary restenosis was 37.2%, 68.6%, and 80.0%, and TLR was 84.8%, 73.0%, and 64.5%, respectively. CLI was the only adverse predictor for decreased primary patency (hazard ratio [HR] 0.36; 95% confidence interval [CI] 0.16-0.80, p = 0.012), whereas significantly less restenosis was detected after spot stenting of the entry and/or re-entry site (HR 0.31; 95% CI 0.10-0.89, p = 0.01 and HR 0.20; 95% CI 0.07-0.56, p = 0.002, respectively). Conclusions: Subintimal angioplasty is a safe and effective revascularization technique for the treatment of CTOs of the femoropopliteal artery. Provisional stenting may have a role at the subintimal entry or true lumen re-entry site.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Management of the Arteria Profunda Femoralis: Long-Term Angiographic and Clinical Outcomes

Purpose: This study was designed to investigate the long-term angiographic and clinical outcomes of percutaneous transluminal angioplasty (PTA) of the arteria profunda femoralis (PFA), in a series of patients suffering from critical limb ischemia (CLI) or severe intermittent claudication (IC). Methods: Our department's database was searched to identify patients who underwent PTA or bail-out stenting of the PFA. Among the study's inclusion criteria were Rutherford categories 3-6 and {>=}70% stenosis of the PFA. Only de novo stenotic lesions were assessed. Primary endpoints were technical success, angiographic lesion primary patency, angiographic binary in-lesion restenosis, and target lesion recanalization (TLR) rates. Secondary endpoints included patient survival, limb salvage, and complication rates. Patient's baseline demographics, lesion, and procedural details were analyzed. Results: Between 2001 and 2011, 20 consecutive patients (17 males) with a mean age of 73 {+-} 9 (range 53-87) years underwent PTA or bail-out stenting in 23 PFA lesions. Critical limb ischemia was the indication in eight of 20 patients (40%). The mean lesion length was 31 {+-} 9.5 mm. The procedural technical success was 100% (23/23), whereas mean time angiographic and clinical follow-up was 26.8 {+-} 24.6 months. According to the Kaplan-Meier analysis, primary patency and binary restenosis rate were 95 and 86.1% respectively up to 8 years follow-up. No TLR procedures were performed. The 8-year patient survival and limb salvage rates were 87.5 and 84.7% respectively. Conclusions: PTA or stenting of focal, stenotic, PFA lesions, in patients suffering from CLI or IC, exhibit high long-term primary patency rates, as well as low binary restenosis and TLR rates. Large, multicenter studies are required to validate these results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fracture and Collapse of Balloon-Expandable Stents in the Bilateral Common Iliac Arteries Due to Shiatsu Massage

We report a case of stent fracture and collapse of balloon-expandable stents caused by shiatsu massage. A 76-year-old man presented with complaints of intermittent claudication of the right lower extremity. Stenoses of the bilateral common iliac arteries (CIAs) were detected. Balloon-expandable stents were deployed in both CIAs, resulting in resolution of symptoms. Five months later, pelvis x-ray showed collapse of both stents. Despite the stent collapse, the patient was asymptomatic, and his ankle brachial index values were within the normal range. Further history showed that the patient underwent daily shiatsu therapy in the umbilical region, which may have triggered collapse of the stent. Physicians should advise patients to avoid compression of the abdominal wall after implantation of a stent in the iliac artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cutting-Balloon Angioplasty Versus Balloon Angioplasty as Treatment for Short Atherosclerotic Lesions in the Superficial Femoral Artery: Randomized Controlled Trial

Purpose: To evaluate the treatments of a short-segment atherosclerotic stenosis in the superficial femoral arteries with the cutting balloon angioplasty (CBA) versus conventional balloon angioplasty [percutaneous transluminal angioplasty (PTA)] in a randomized controlled trial. Material and Methods: The study group comprised 60 patients (33 men, 27 women; average age 64 years) with a short ({<=}5 cm) focal SFA de novo atherosclerotic stenosis associated with a history of intermittent claudication or rest pain. The primary end point of this study was the rate of binary restenosis in the treated segment 12 months after the intervention. All patients were evenly randomized to either the PTA or CBA treatment arms. Follow-up angiograms and ankle-brachial index (ABI) measurements were performed after 12 months. The evaluation of the restenosis rates and factors influencing its occurrence were calculated by logistic regression analysis. Results: In the intention-to-treat analysis, restenosis rates after 2-month follow-up were 9 of 30 (30 %) in the PTA group and 4 of 30 (13 %) in the CBA group (p = 0.117). In the actual treatment analysis, after exclusion of patients who required nitinol stent placement for a suboptimal result after angioplasty alone (5 patients in the PTA group and none in the CBA group), restenosis rates were 9 of 25 (36 %) and 4 of 30 (13 %), respectively (p = 0.049). In the intention-to-treat analysis there were also significant differences in ABI values between the PTA and CBA groups at 0.77 {+-} 0.11 versus 0.82 {+-} 0.12, respectively (p = 0.039), at 12 months. Conclusion: Based on the presented results of the trial, CBA seems to be a safer and more effective than PTA for treatment of short atherosclerotic lesions in the superior femoral artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Arterial Embolization with n-Butyl Cyanoacrylate for the Treatment of Acquired Uterine Vascular Malformations

PurposeThe purpose of the study was to evaluate the technique and outcomes of transcatheter arterial embolization (TAE) with n-butyl cyanoacrylate (NBCA) for the treatment of acquired uterine arteriovenous malformations (AVMs).Materials and methodsA retrospective review identified five women treated for suspected acquired uterine AVMs with TAE at our institution. Four women (80 %) presented with heavy or intermittent vaginal bleeding after obstetric manipulation. One woman (20 %) was treated for an incidental AVM discovered on ultrasound after an uncomplicated cesarean section. Three women underwent one embolization procedure and two women required two procedures. Embolization material included NBCA in six procedures (80 %) and gelatin sponge in one procedure (20 %).ResultsEmbolization resulted in angiographic stasis of flow in all seven procedures. Four women (80 %) presented with vaginal bleeding which was improved after treatment. One woman returned 24 days after unilateral embolization with recurrent bleeding, which resolved after retreatment. One woman underwent two treatments for an asymptomatic lesion identified on ultrasound. There were no major complications. Three women (60 %) experienced mild postembolization pelvic pain that was controlled with non-steroidal anti-inflammatory drugs. Three women (60 %) had pregnancies and deliveries after embolization.ConclusionsTAE is a safe alternative to surgical therapy for acquired uterine AVMs with the potential to maintain fertility. Experience from this case series suggests that NBCA provides predictable and effective occlusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Day-Case Treatment of Peripheral Arterial Disease: Results from a Multi-Center European Study

PurposeThe purpose of the study was to investigate safety and feasibility of day-case endovascular procedures for the management of peripheral arterial disease.Materials and MethodsThis was a multi-center, retrospective study including all patients treated over a 30-month period with endovascular angioplasty or stenting for intermittent claudication (IC) or critical limb ischemia (CLI) on a day-case basis, in Interventional Radiology (IR) departments of three European tertiary hospitals. Exclusion criteria were not related to the type of lesion and included unavailability of an adult able to take care of patient overnight; high bleeding risk and ASA score ≥4. Primary efficacy outcome was the rate of procedures performed on an outpatient basis requiring no further hospitalization and primary safety outcome was freedom from 30-day major complications’ rate.ResultsThe study included 652 patients (male 75 %; mean age 68 ± 10 years; range: 27–93), 24.6 % treated for CLI. In 53.3 % of the cases a 6Fr sheath was used. Technical success was 97.1 %. Haemostasis was obtained by manual compression in 52.4 % of the accesses. The primary efficacy outcome occurred in 95.4 % (622/652 patients) and primary safety outcome in 98.6 % (643/652 patients). Major complications included five (0.7 %) retroperitoneal hematomas requiring transfusion; one (0.1 %) common femoral artery pseudoaneurysm successfully treated with US-guided thrombin injection, two cases of intra-procedural distal embolization treated with catheter-directed local thrombolysis and one on-table cardiac arrest necessitating >24 h recovery. No major complication was noted after same-day discharge.ConclusionsDay-case endovascular procedures for the treatment of IC or CLI can be safely and efficiently performed in experienced IR departments of large tertiary hospitals.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MRI-guided Wire Localization Surgical Biopsy in an Adolescent Patient with a Difficult to Diagnose Case of Lymphoma

A 17-year-old previously healthy female presented with a progressive soft tissue infiltrative process involving the neck and thorax. Extensive diagnostic evaluation including multiple imaging, laboratory, and biopsy studies was nondiagnostic. Due to an urgent need to establish a diagnosis and several previous nondiagnostic biopsies, she was referred to interventional radiology for MRI-guided wire localization immediately prior to open surgical biopsy. Under general anesthesia, wires were placed in the areas of increased T2 signal within the bilateral splenius capitis muscles using intermittent MRI-guidance followed by immediate surgical biopsy down to the wires. Pathology confirmed the diagnosis of diffuse large B-cell lymphoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proximal Occlusion of Medium-Sized Vessels with the Penumbra Occlusion Device: A Study of Safety and Efficacy

PurposeTo retrospectively investigate the safety and efficacy of hybrid proximal coiling of various medium-sized vessels (4 to 8 mm) using the Penumbra Occlusion Device (POD).Materials and MethodsFrom October 2014 to February 2016, 37 proximal embolizations were performed with PODs in 36 patients (mean age: 50.8, range: 10–86; 29 male, 7 female). Vessel occlusions were achieved under fluoroscopic guidance using a 2.7 French microcatheter. Among the 36 vessels targeted, 16 were splenic arteries, 11 renal arteries, 4 mesenteric arteries, 3 arteriovenous fistulae, 1 iliac artery, and 1 gonadal vein. Intermittent follow-up angiography was performed to assess the flow for final occlusion. Outcomes and complications were assessed by clinical and/or imaging follow-up.ResultsTo produce proximal occlusion of the intended vessels, the POD was used alone in 19 embolizations (51.4 %). In 12 procedures (32.4 %), POD was used as a coil constrainer to secure the coil construct. In 6 procedures (16.2 %), additional embolic devices were used to achieve vessel occlusion after initial POD deployment. After a mean follow-up of 3.2 months, no POD migration was observed but two complications occurred (5.4 %): one post embolic syndrome and one extensive infarction with splenic abscess.ConclusionThe POD system allows safe and effective proximal embolization of medium-sized vessels in a variety of clinical settings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostatic Tissue Elimination After Prostatic Artery Embolization (PAE): A Report of Three Cases

PurposeWe report three cases of spontaneous prostatic tissue elimination through the urethra while voiding following technically successful prostatic artery embolization (PAE) as a treatment for lower urinary tract symptoms (LUTS) related to benign prostatic hyperplasia (BPH).MethodsAll patients were embolized with 100- to 300-μm microspheres alone or in combination with 300- to 500-μm microspheres.ResultsDuring follow-up prior to eliminating the tissue fragments, the three patients all presented with intermittent periods of LUTS improvement and aggravation. After expelling the prostatic tissue between 1 and 5 months of follow-up, significant improvements in LUTS and urodynamic parameters were observed in all patients.ConclusionsUrethral obstruction after PAE caused by sloughing prostate tissue is a potential complication of the procedure and should be considered in patients with recurrent LUTS in order to avoid inappropriate management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Frequency Jet Ventilation During Cryoablation of Small Renal Tumours

AimTo evaluate the effect of high-frequency jet ventilation (HFJV) in place of standard intermittent positive-pressure ventilation (IPPV) on procedure duration, patient radiation dose, complication rates, and outcomes during CT-guided cryoablation of small renal tumours.Materials and MethodsOne hundred consecutive CT-guided cryoablation procedures to treat small renal tumours under general anaesthesia were evaluated—50 with standard IPPV and 50 after the introduction of HFJV as standard practice. Anaesthesia and procedural times, ionising radiation dose, complications, and 1-month post-treatment outcomes were collected.ResultsHFJV was feasible and safe in all cases. Mean procedure time and total anaesthetic time were shorter with HFJV (p = <0.0001). The number of required CT acquisitions (p = 0.0002) and total procedure patient radiation dose (p = 0.0027) were also lower in the HFJV group compared with the IPPV group. There were a total of four complications of Clavien–Dindo classification 3 or above—three in the IPPV group and one in the HFJV group. At 1-month follow-up, two cases (both in the IPPV group) demonstrated subtotal treatment. Both cases were subsequently successfully retreated with cryoablation.ConclusionBy reducing target tumour motion during CT-guided renal cryoablation, HFJV can reduce procedure times and exposure to ionising radiation. HFJV provides an important adjunct to complex image-guided interventions, with potential to improve safety and treatment outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Transcatheter Arterial Microembolization on Phantom Limb Pain Persisting for 17 Years

Phantom limb pain is a frequent consequence of the amputation; currently available treatments are far from satisfactory. The present report describes a case in which transcatheter arterial microembolization had a remarkable curative effect on phantom limb pain persisting for 17 years. The patient began feeling phantom limb sensations and brief intermittent pain following lower limb amputation above the knee in 2001. The frequency, intensity, and duration of the pain increased over time, and it was resistant to conservative treatments. Following transcatheter arterial microembolization in 2018, patient immediately experienced marked improvement. The pain has been infrequent, much less intense, and did not interfere with daily life 6 months posttreatment. Transcatheter arterial microembolization could be an alternative treatment option for phantom limb pain. Level of Evidence: IV, Case Report.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volcanic electrification: recent advances and future perspectives

Abstract The electrification of volcanic plumes has been described intermittently since at least the time of Pliny the Younger and the 79 AD eruption of Vesuvius. Although sometimes disregarded in the past as secondary effects, recent work suggests that the electrical properties of volcanic plumes reveal intrinsic and otherwise inaccessible parameters of explosive eruptions. An increasing number of volcanic lightning studies across the last decade have shown that electrification is ubiquitous in volcanic plumes. Technological advances in engineering and numerical modelling, paired with close observation of recent eruptions and dedicated laboratory studies (shock-tube and current impulse experiments), show that charge generation and electrical activity are related to the physical, chemical, and dynamic processes underpinning the eruption itself. Refining our understanding of volcanic plume electrification will continue advancing the fundamental understanding of eruptive processes to improve volcano monitoring. Realizing this goal, however, requires an interdisciplinary approach at the intersection of volcanology, atmospheric science, atmospheric electricity, and engineering. Our paper summarizes the rapid and steady progress achieved in recent volcanic lightning research and provides a vision for future developments in this growing field.

58 GEOSCIENCES↗

Cutting planes for the multistage stochastic unit commitment problem

As renewable energy penetration rates continue to increase in power systems worldwide, new challenges arise for system operators in both regulated and deregulated electricity markets to solve the security-constrained coal-fired unit commitment problem with intermittent generation (due to renewables) and uncertain load, in order to ensure system reliability and maintain cost effectiveness. In this paper, we study a security-constrained coal-fired stochastic unit commitment model, which we use to enhance the reliability unit commitment process for day-ahead power system operations. In our approach, we first develop a deterministic equivalent formulation for the problem, which leads to a large-scale mixed-integer linear program. Then, we verify that the turn on/off inequalities provide a convex hull representation of the minimum-up/down time polytope under the stochastic setting. Next, we develop several families of strong valid inequalities mainly through lifting schemes. In particular, by exploring sequence independent lifting and subadditive approximation lifting properties for the lifting schemes, we obtain strong valid inequalities for the ramping and general load balance polytopes. Lastly, branch-and-cut algorithms are developed to employ these valid inequalities as cutting planes to solve the problem. Our computational results verify the effectiveness of the proposed approach.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Rapid denitrification of nitrate-contaminated groundwater in a low-gradient blackwater stream valley

Leaching of excess nitrogen (N) to groundwater in fertilized landscapes can overwhelm natural biogeochemical processes and cause long-term eutrophication of aquatic systems. We investigated N fate and transport from an intensively managed short-rotation woody crop (Pinus taeda) plantation through the riparian zone of an intermittent, low-gradient blackwater stream. Fertilization of the P. taeda plantation on the uplands resulted in contamination of groundwater with nitrate concentrations between 0.9 and 1.9 mg N L -1 . No corresponding increase in nitrate was observed in stream water or shallow groundwater in the riparian zone. Groundwater travel-time modeling predicted that N from near-stream, upland plantation areas should have reached streams during the monitoring period. Two years of measuring N species in well water in contrasting landscape positions (within the plantation, swale, riparian edge, forested hillslope, and valley), indicated rapid nitrate transformation and denitrification within the forested wetland valleys. Denitrification in the shallow groundwater system within the toeslopes and the riparian zone was estimated to have removed > 90% of nitrate. Finally, these results highlight the importance of riparian zones as pathways for the removal of N and for controlling downstream N loads.

54 ENVIRONMENTAL SCIENCES↗

Coordinative Entities: Forms of Organizing in Data Intensive Science

Scientific collaboration is a long-standing subject of CSCW scholarship that typically focuses on the development and use of computing systems to facilitate research. The research presented in this article investigates the sociality of science by identifying and describing particular, common forms of organizing that researchers in four different scientific realms employ to conduct work in both local contexts and as part of distributed, global projects. This paper introduces five prototypical forms of organizing we categorize as coordinative entities: the Principal Group, Intermittent Exchange, Sustained Aggregation, Federation, and Facility Organization. Coordinative entities as a categorization help specify, articulate, compare, and trace overlapping and evolving arrangements scientists use to facilitate data intensive research. We use this typology to unpack complexities of data intensive scientific collaboration in four cases, showing how scientists invoke different coordinative entities across three types of research activities: data collection, processing, and analysis. Finally, our contribution scrutinizes the sociality of scientific work to illustrate how these actors engage in relational work within and among diverse, dispersed forms of organizing across project, funding, and disciplinary boundaries.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Imputation of urban environmental sensor data using gated attention bidirectional long short-term memory (GA-BiLSTM): methods, performance, and implications

Urban environmental monitoring networks frequently encounter significant data gaps due to sensor malfunctions, environmental disturbances, and communication failures. Reliable approaches to address these gaps are essential for ensuring the continuity and quality of environmental data streams. In this study, we developed a gated attention bidirectional long short-term memory (GA-BiLSTM) model to impute missing data in a dense urban monitoring network. Using observations from the CROCUS network in Chicago, we evaluated GA-BiLSTM against widely used approaches (XGBoost and K-nearest neighbors) under scenarios of both short-term intermittent gaps and prolonged outages. GA-BiLSTM consistently outperformed comparative methods, particularly during extended outages of up to ten days, demonstrating its ability to capture spatiotemporal dependencies across sensor nodes. Beyond performance metrics, feature importance and spatial network analyses highlighted the unexpected but critical predictive role of peripheral rural nodes, underlining their strategic value for maintaining robust urban monitoring systems. These results emphasize that advanced imputation methods can substantially improve the reliability of environmental monitoring networks and support more resilient data infrastructures for urban sustainability.

Data imputation↗

Comparative study of monolithic platinum and iridium as oxygen-evolving anodes during the electrolytic reduction of uranium oxide in a molten LiCl–Li 2 O electrolyte

A series of four electrolytic reduction runs was performed in molten salt at bench scale to compare the performance characteristics of monolithic platinum and iridium as oxygen-evolving anodes, while simultaneously reducing uranium oxide to metal. In each run, 25 g of uranium oxide particulate was loaded into a permeable steel basket, which, in turn, was immersed in a pool of LiCl—1 wt% Li 2 O at 650 °C. Both anodes, each 3 mm in diameter, were suspended vertically in the salt pool, adjacent to the steel cathode basket. The anodes were connected in parallel to separate direct current power supplies with the uranium oxide-loaded basket as the common cathode. A cell voltage (3.1 V) was intermittently applied to the system with both power supplies operating concurrently, effecting the reduction of uranium oxide to uranium metal at the cathode basket and the simultaneous oxidation of oxygen anions in the salt to oxygen gas at each anode. Anode and cathode potentials and currents were recorded to compare the performance of platinum vis-à-vis iridium. After completing the series of runs, both anodes were removed and subjected to dimensional, chemical, and microscopic analyses. Furthermore the accumulated charges on each anode over the series of four runs were similar, the platinum anode exhibited up to 29% reduction in cross-sectional area compared to <3% for the iridium anode.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗