Search NASA⌕ Search

SEARCH · Search NASA

Results for “long term testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Differences in Pre and Post Vascular Patterning Within Retinas from ISS Crew Members and Head-Down Tilt (HDT) Subjects by VESGEN Analysis

Accelerated research by NASA has investigated the significant risks incurred during long-duration missions in microgravity for Space Flight-Associated Neuro-ocular Syndrome (SANS, formerly known as Visual Impairments associated with Increased Intracranial Pressure, VIIP) [1]. For our study, NASA's VESsel GENeration Analysis (VESGEN) was used to investigate the role of retinal blood vessels in the etiology of SANS/VIIP. The response of retinal vessels to microgravity was evaluated in astronaut crew members pre and post flight to the International Space Station (ISS), and compared to the response of retinal vessels in healthy volunteers to 6deg head-down tilt during 70 days of bed rest (HDTBR). For the study, we are testing the hypothesis that long-term cephalad fluid shifts resulting in ocular and visual impairments are necessarily mediated in part by retinal blood vessels, and therefore are accompanied by structural adaptations of the vessels. METHODS: Vascular patterns in the retinas of crew members and HDTBR subjects extracted from 30deg infrared (IR) Heidelberg Spectralis images collected pre/postflight and pre/post HDTBR, respectively, were analyzed by VESGEN (patent pending). VESGEN is a mature, automated software developed as a research discovery tool for progressive vascular diseases in the retina and other tissues. The multi-parametric VESGEN analysis generates maps of branching arterial and venous trees quantified by parameters such as the fractal dimension (Df, a modern measure of vascular space-filling capacity), vessel diameters, and densities of vessel length and number classified into specific branching generations according to vascular physiological branching rules. The retrospective study approved by NASA's Institutional Review Board included the analysis of bilateral retinas in eight ISS crew members monitored by routine occupational surveillance and six HDTBR subjects (NASA FARU Campaign 11, for example). The VESGEN analysis was conducted in a blinded fashion, with IR retinal images masked to the subject's identity, ophthalmic and clinical characteristics, and to the temporal sequence of image collection. To complete our study, VESGEN results will be analyzed statistically and correlated with other ophthalmic and medical findings. RESULTS: Preliminary results for changes in the pre to post status of vascular patterning in the retinas of crew members and HDTBR subjects are interestingly opposite. By Df and other vascular branching measures, the space-filling capacity of arterial and venous trees decreased in the majority of crew members (11/16 retinas). In contrast, vascular densities increased in HDTBR subjects by the same parameters (6/10 retinas). To conclude the study, biostatistics and medical analyses will be conducted to quantify and draw conclusions about how the changes associated with flight compare to those associated with HDTBR. CONCLUSIONS: Vascular densities appeared to decrease in the retinas of ISS crew members and increase in HDTBR subjects. Differences in arterial and venous response to cephalad fluid shifts induced by ISS and HDTBR may have resulted from a long-duration conditioning phenomenon (for example, 6-month ISS missions compared to 70 days HDTBR), or the presence of gravity in HDTBR compared to microgravity on the ISS. In addition, increased and decreased vessel diameters for Crew Members and HDTBR, respectively, are subject to limits of im

Vascular↗

Voltage Stability Assessment Using Synchronized Phasor Measurements Applied to the Argentine Power System

This paper presents tests of different methods for long term voltage stability analysis based on PMU measurements. In particular, Thevenin Impedance Matching and sensitivity calculation are studied. Simulation are performed in a modified Argentine power system model, to include the main components for studying long term voltage stability. Disconnection of a large Thermal Generating Station causing long-term voltage instability at Gran Buenos Aires Area is studied. It is shown that computing the apparent impedance of Thevenin equivalent at load bus from measurements taken at a single time but at various locations of the transmission corridor produce a significant reduction of the estimation error produce when only local measurements are used. Voltage Stability analysis is performed using a reduced power system model where changing parameters are fully computed through PMU data at each time. Over this reduced power system model, voltage stability index and sensibility calculations are performed.

Gill-Estebez, Pablo↗

Studies on the Encapsulation of Brine Generated from a Process Using Selective Electrodialysis Reversal

This topical report summarizes the laboratory testing, geochemical modeling, and mineralogical testing conducted to examine the efficacy of wastewater encapsulation for the brine generated from the Saltworks Flex electrodialysis reversal technology. Within the laboratory testing, the short- and long-term physical properties of seven separate mix designs were examined along with the leaching of each mix design. Additionally, geochemical thermodynamic modeling was used along with mineralogical analyses to help gain a fundamental understanding of the chemistry involved in the encapsulation process. Encapsulation is a process that results in the immobilization of constituents of interest by creating an engineered material that contains the waste within its matrix, both physically and chemically, in such a manner that the receiving environment is protected from adverse effects. Within the context of this study, encapsulation mix designs involved mixing the Saltworks brine with fly ash and various additives, principally lime (calcium oxide) and cement, to form a paste that eventually sets and hardens into a monolith upon placement in a landfill. Moisture conditioning fly ash with wastewater sources for on-site landfill disposal is a process that is in use at some sites and has been presented as a viable option to dispose of liquid wastes. However, because chemical reactions that can lead to sequestration of constituents of interest are not optimized, leaching can occur. Therefore, in this study, mixes were created to mimic moisture conditioning, as well as engineered pastes of varying mix designs. The study found that engineered encapsulation mixes provide significant resistance to leaching compared to moisture conditioning alone. The best performing encapsulation mix used lime as the additive, which proved superior to the use of cement. After 90 days of curing, this encapsulated mix was 5.5 times stronger than the moisture conditioned mix. Additionally, this mix exhibited an approximate 2.5 order of magnitude drop in hydraulic conductivity compared to the moisture conditioned mix. When comparing leaching, nearly all the chloride was found to evolve from the moisture conditioned mix, whereas only 6.7% of the chlorine contained in the best performing encapsulated mix leached out. Mineralogical analysis via X-ray diffraction (XRD) showed a significant concentration of the chloride sequestering mineral, Friedel’s salt, in the best performing encapsulation mix, whereas none was observed in the moisture conditioned mix, pointing to it being the primary chemical mechanism for chloride retention, along with the physical impermeability of the material. With respect to the modeling study, the model was successful in predicting the presence of most mineral phases observed in the XRD analysis.

01 COAL, LIGNITE, AND PEAT↗

Influence of dissolved salts and impurities on seawater on heat transfer and fluid flow through fuel channels and debris bed

This project aims to better understand this mechanism and its effect on heat transfer. Specifically, experimental research was conducted to investigate the long term coolability issues in scaled test setups. Advanced diagnostic and measurement techniques were investigated and incorporated into an annular test facility and a debris bed test facility. The diagnostic techniques investigated included: radioactively tagged salt solution, Frisch collar radiation detector array, neutron and x-ray imaging systems, and a Rayleigh backscatter-based fiber-optic temperature system. Models were checked against the in-situ experimental data and recommendations were made for modeling purposes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Low Activity Waste Glass Waste Form Data Package for Hanford's Integrated Disposal Facility Performance Assessment - 16480

A Direct Feed Low Activity Waste (DFLAW) flowsheet has been initiated to begin immobilization of Hanford tank wastes. In the DFLAW configuration, a pretreatment system will segregate the high level and the low activity wastes (LAW). The LAW will be immobilized in the Waste Treatment Plant (WTP) and disposed of in Hanford's Integrated Disposal Facility (IDF). To obtain authorization to dispose of wastes in the IDF, a Performance Assessment (PA) must be completed in accordance with DOE Order 435.1. The PA shall include calculations of potential doses to representative future members of the public and potential releases from the facility to provide a reasonable expectation that performance objectives will not be exceeded as a result of operation and closure of the facility. To support the development of the PA, data from ILAW glass testing are needed to model the long term release of contaminants over the compliance period and verify that impacts to groundwater quality will be within performance objective limits. Washington River Protection Solutions is conducting an ILAW glass testing program to produce the required data. This program is a combined effort involving National Laboratories with known expertise in glass waste form research. The work involves accelerated testing to develop parameters that can be used in computer simulations of glass corrosion and contaminant release in the IDF environment. The results of this work will be compiled in an ILAW glass waste form performance data package for the IDF PA. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data from: Lowland Tropical Forests Remain a Methane Sink Under Warming and Long-Term Hurricane Disturbance Recovery

The repository folder contains spreadsheets and script for soil greenhouse gas (GHG) fluxes, soil moisture, soil temperature, air temperature, and precipitation measurements collected from the Tropical Responses to Altered Climate Experiment (TRACE) at the Sabana Research Field Station, El Yunque National Forest (USDA Forest Service; 18°19′28.74″ N, 65°43′50.09″ W) — an open-air field warming experiment located in a lowland tropical forest in Puerto Rico within the Luquillo Experimental Forest (LEF) — six to seven years after Hurricanes Irma and Maria (2017). All spreadsheets for soil and air microclimate data, as well as soil greenhouse gas data, are included as csv files. Air temperature data are also included as Excel spreadsheets (.xlsx). The script is built in R Studio, which is the only software required to run data analysis. This dataset is associated with the manuscript “Larocca Conte G ; Zuvela L ; Cruz-Pérez R ; Barreto-Vélez T ; Becerra-Santillan N ; Campbell S ; Chu H ; Dam T ; Grullón-Penkova I ; Kleit M ; Ortiz-Iglesias D ; Rubio-Lebrón L ; Cavaleri M ; Reed S ; Sihi D ; Wood T ; O'Connell C., 2026. Lowland Tropical Forests Remain a Methane Sink Under Warming and Long-Term Hurricane Disturbance Recovery. Agricultural and Forest Meteorology. In review". The dataset was used to test the effect of warming on soil CH4 dynamics following long-term legacy effects of hurricane disturbance. The dataset includes: - An overall README file in word and pdf format describing methodology and spreadsheets’ structure. - Continuous measurements of soil temperature and moisture from January 2023 to July 2024 measured with Campbell CS655 probes (“TRACE_soil_temperature_and_moisture_2023_cleaned(in).csv” and “TRACE_soil_temperature_and_moisture_2024_cleaned. csv”). - Air temperature data measured with a HOBO MX23O1A data logger (“Hobo air temperature 2023 Sep 2024” and “Hobo air temperature 2023 Sep 2024” – “CSV FILES folders”). - Precipitation data from a nearby weather tower downloaded from González et al. (2025; “sabana_2020-2025.csv”). - Soil CH4 and CO2 effluxes measured intermittently in two summer campaigns (June – August 2023 and June – July 2024) with a LI-COR 8200-01S Portable Smart Chamber coupled with a LI-COR LI-7810 CH4/ CO2/H2O Trace Gas Analyzer (“23_24COMBO2.0.csv”). - R markdown script for data analysis (“Trace new_PLOTS.Rmd”).

54 ENVIRONMENTAL SCIENCES↗

Effect of short-term microgravity and long-term hindlimb unloading on rat cardiac mass and function

The purpose of this study was to test the hypothesis that exposure to short-term microgravity or long-term hindlimb unloading induces cardiac atrophy in male Sprague-Dawley rats. For the microgravity study, rats were subdivided into four groups: preflight (PF, n = 12); flight (Fl, n = 7); flight cage simulation (Sim, n = 6), and vivarium control (Viv, n = 7). Animals in the Fl group were exposed to 7 days of microgravity during the Spacelab 3 mission. Animals in the hindlimb-unloading study were subdivided into three groups: control (Con, n = 20), 7-day hindlimb-unloaded (7HU, n = 10), and 28-day hindlimb-unloaded (28HU, n = 19). Heart mass was unchanged in adult animals exposed to 7 days of actual microgravity (PF 1.33 +/- 0.03 g; Fl 1.32 +/- 0.02 g; Sim 1.28 +/- 0.04 g; Viv 1.35 +/- 0.04 g). Similarly, heart mass was unaltered with hindlimb unloading (Con 1.40 +/- 0.04 g; 7HU 1.35 +/- 0.06 g; 28HU 1.42 +/- 0.03 g). Hindlimb unloading also had no effect on the peak rate of rise in left ventricular pressure, an estimate of myocardial contractility (Con 8,055 +/- 385 mmHg/s; 28HU 8,545 +/- 755 mmHg/s). These data suggest that cardiac atrophy does not occur after short-term exposure to microgravity and that neither short- nor long-term simulated microgravity alters cardiac mass or function.

manned↗

Closure End States for Facilities, Waste Sites, and Subsurface Contamination

The United States (U.S.) Department of Energy (DOE) manages the largest groundwater and soil cleanup effort in the world. DOE’s Office of Environmental Management (EM) has made significant progress in its restoration efforts at sites such as Fernald and Rocky Flats. However, remaining sites, such as Savannah River Site, Oak Ridge Site, Hanford Site, Los Alamos, Paducah Gaseous Diffusion Plant, Portsmouth Gaseous Diffusion Plant, and West Valley Demonstration Project possess the most complex challenges ever encountered by the technical community and represent a challenge that will face DOE for the next decade. Closure of the remaining 18 sites in the DOE EM Program requires remediation of 75 million cubic yards of contaminated soil and 1.7 trillion gallons of contaminated groundwater, deactivation & decommissioning (D&D) of over 3000 contaminated facilities and thousands of miles of contaminated piping, removal and disposition of millions of cubic yards of legacy materials, treatment of millions of gallons of high level tank waste and disposition of hundreds of contaminated tanks. The financial obligation required to remediate this volume of contaminated environment is estimated to cost more than 7% of the to-go life-cycle cost. Critical in meeting this goal within the current life-cycle cost projections is defining technically achievable end states that formally acknowledge that remedial goals will not be achieved for a long time and that residual contamination will be managed in the interim in ways that are protective of human health and environment. Formally acknowledging the long timeframe needed for remediation can be a basis for establishing common expectations for remedy performance, thereby minimizing the risk of re-evaluating the selected remedy at a later time. Once the expectations for long-term management are in place, remedial efforts can be directed towards near-term objectives (e.g., reducing the risk of exposure to residual contamination) instead of focusing on long-term cleanup requirements. An acknowledgement of the long timeframe for complete restoration and the need for long-term management can also help a site transition from the process of pilot testing different remedial strategies to selecting a final remedy and establishing a long-term management and monitoring approach. This approach has led to cost savings and the more efficient use of resources across the Department of Defense complex and at numerous industrial sites across the U.S. Defensible end states provide numerous benefits for the DOE environmental remediation programs including cost-effective, sustainable long-term monitoring strategies, remediation and site transition decision support, and long-term management of closure sites.

environmental remediation↗

Closure End States for Facilities, Waste Sites, and Subsurface Contamination - 12543

The United States (U.S.) Department of Energy (DOE) manages the largest groundwater and soil cleanup effort in the world. DOE's Office of Environmental Management (EM) has made significant progress in its restoration efforts at sites such as Fernald and Rocky Flats. However, remaining sites, such as Savannah River Site, Oak Ridge Site, Hanford Site, Los Alamos, Paducah Gaseous Diffusion Plant, Portsmouth Gaseous Diffusion Plant, and West Valley Demonstration Project possess the most complex challenges ever encountered by the technical community and represent a challenge that will face DOE for the next decade. Closure of the remaining 18 sites in the DOE EM Program requires remediation of 75 million cubic yards of contaminated soil and 1.7 trillion gallons of contaminated groundwater, deactivation and decommissioning (D and D) of over 3000 contaminated facilities and thousands of miles of contaminated piping, removal and disposition of millions of cubic yards of legacy materials, treatment of millions of gallons of high level tank waste and disposition of hundreds of contaminated tanks. The financial obligation required to remediate this volume of contaminated environment is estimated to cost more than 7% of the to-go life-cycle cost. Critical in meeting this goal within the current life-cycle cost projections is defining technically achievable end states that formally acknowledge that remedial goals will not be achieved for a long time and that residual contamination will be managed in the interim in ways that are protective of human health and environment. Formally acknowledging the long timeframe needed for remediation can be a basis for establishing common expectations for remedy performance, thereby minimizing the risk of re-evaluating the selected remedy at a later time. Once the expectations for long-term management are in place, remedial efforts can be directed towards near-term objectives (e.g., reducing the risk of exposure to residual contamination) instead of focusing on long-term cleanup requirements. An acknowledgement of the long timeframe for complete restoration and the need for long-term management can also help a site transition from the process of pilot testing different remedial strategies to selecting a final remedy and establishing a long-term management and monitoring approach. This approach has led to cost savings and the more efficient use of resources across the Department of Defense complex and at numerous industrial sites across the U.S. Defensible end states provide numerous benefits for the DOE environmental remediation programs including cost-effective, sustainable long-term monitoring strategies, remediation and site transition decision support, and long-term management of closure sites. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lithium-Ion Cell Storage Study

This viewgraph presentation reviews the issues concerning storage of lithium ion batteries. The presentation outlines tests used to establish a best long term storage for the lithium ion cells. Another objective of the study was to determine the preferred solstice condition for the lithium ion chemistry (polymer and liquid electrolyte). It also compared voltage clamped with trickle charge storage. The tests and results are reviewed

Lee, Leonine↗

FINAL TECHNICAL REPORT

NIST has played a key role in many of the one-on-one, domestic, and international interlaboratory comparisons of measurements on superconductors. The history of interlaboratory comparisons of measurements on superconductors tells us that careful measurement methods are needed to obtain consistent results. Inconsistent results can lead to many problems including: a mistrust of the results of others, unfair advantages in commerce, and erroneous feedback in the optimization of conductor performance. NIST has experience in many interlaboratory comparisons; a long-term commitment to measurement accuracy; and independent, third-party laboratory status. The principal investigator's direct involvement in the measurements and daily supervision of sample mounting is the unique situation that has allowed important discoveries and evolution of our capabilities over the last 30 years. The principal investigator's research and metrology has helped to improve the accuracy of critical-current (I{sub c}) measurements in laboratories throughout the world. As conductors continue to improve and design limits are tested, the continuation of the long-term commitment to measurement accuracy could be vitally important to the success of new conductor development programs. It is extremely important to the U.S. wire manufacturers to get accurate (high certainty) I{sub c} measurements in order to optimize conductor performance. The optimization requires the adjustment of several fabrication parameters (such as reaction time, reaction temperature, conductor design, doping, diffusion barrier, Cu to non-Cu ratio, and twist pitch) based on the I{sub c} measurement of the conductor. If the I{sub c} measurements are made with high variability, it may be unclear whether or not the parameters are being adjusted in the optimal direction or whether or not the conductor meets the target specification. Our metrology is vital to the U.S. wire manufacturers in the highly competitive international arena and to meet the aggressive performance goals. The latest high-performance Nb{sub 3}Sn wires are being designed with higher current densities, larger effective filament diameter, less Cu stabilizer, and, in some cases, larger wire diameters than ever before. In addition, some of the conductor designs and heat treatments cause the residual resistivity ratio (RRR, ratio of room temperature resistivity to the resistivity at 20 K) of the stabilizer to be less than 20. These parameters are pushing the conductors towards less intrinsic stability, into a region we call marginally stable. These parameters also create a whole series of challenges for routine I{sub c} testing on short-samples, even when tested with the sample immersed in liquid helium. High-current, variable-temperature I{sub c} measurements are even more difficult than those made in liquid helium because the sample is only cooled by flowing helium gas. Providing accurate I{sub c} results under these conditions requires a complex system that provide adequate cooling as well as uniform sample temperature. We have been make variable-temperature measurements for about 15 years, but we started to design the first high-current (at least 500 A), variable-temperature, variable-strain apparatus in late 2006. Our first critical-current measurements as a function of strain, temperature, and magnetic field, I{sub c}(B,T,{var_epsilon}), in a new single, unified apparatus (full matrix characterization) were made in the summer of 2008. This is the only such facility in the U.S. and it has some unique components that are not duplicated anywhere in the world. The compounding of all three variables (H, T, {var_epsilon}) makes an already labor and time intensive characterization very formidable; however, the results cannot be generated any other way and are needed to answer key questions about strain and temperature safety margins and about the reliability of using scaling laws based on small data sets to predict performance. In the future, this new apparatus will allow NIST to create a database on strands that would benefit U.S. superconductor wire manufacturers, national research laboratories, and programs using superconductor strands such as HEP and International Thermonuclear Experimental Reactor (ITER).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of Chemistry-Climate Model Results using Long-Term Satellite and Ground-Based Data

Chemistry-climate models attempt to bring together our best knowledge of the key processes that govern the composition of the atmosphere and its response to changes in forcing. We test these models on a process by process basis by comparing model results to data from many sources. A more difficult task is testing the model response to changes. One way to do this is to use the natural and anthropogenic experiments that have been done on the atmosphere and are continuing to be done. These include the volcanic eruptions of El Chichon and Pinatubo, the solar cycle, and the injection of chlorine and bromine from CFCs and methyl bromide. The test of the model's response to these experiments is their ability to produce the long-term variations in ozone and the trace gases that affect ozone. We now have more than 25 years of satellite ozone data. We have more than 15 years of satellite and ground-based data of HC1, HN03, and many other gases. I will discuss the testing of models using long-term satellite data sets, long-term measurements from the Network for Detection of Stratospheric Change (NDSC) , long-term ground-based measurements of ozone.

Stolarski, Richard S.↗

Accelerated Stress Testing of Multi-Source LED Products: Horticulture Lamps and Tunable-White Modules

This report discusses the use of accelerated stress testing (AST) to provide insights into the long-term behavior of commercial products utilizing different types of mid-power LEDs (MP-LEDs) integrated into the same LED module. Test results are presented from two commercial lamps intended for use in horticulture applications and one tunable-white LED module intended for use in educational and office lighting applications. Each of these products is designed to provide a custom spectrum for their targeted applications and each achieves this goal in different ways. Consequently, a comparison of the long-term stability of these devices will provide insights regarding approaches that could be used to possibly lengthen the lifetime of SSL products.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Investigation of thermolytic hydrogen generation rate of tank farm simulated and actual waste

To support resolution of Potential Inadequacies in the Safety Analysis for the Savannah River Site (SRS) Tank Farm, Savannah River National Laboratory conducted research to determine the thermolytic hydrogen generation rate (HGR) with simulated and actual waste. Gas chromatography methods were developed and used with air-purged flow systems to quantify hydrogen generation from heated simulated and actual waste at rates applicable to the Tank Farm Documented Safety Analysis (DSA). Initial simulant tests with a simple salt solution plus sodium glycolate demonstrated the behavior of the test apparatus by replicating known HGR kinetics. Additional simulant tests with the simple salt solution excluding organics apart from contaminants provided measurement of the detection and quantification limits for the apparatus with respect to hydrogen generation. Testing included a measurement of HGR on actual SRS tank waste from Tank 38. A final series of measurements examined HGR for a simulant with the most common SRS Tank Farm organics at temperatures up to 140 °C. The following conclusions result from this testing. HGR was measured for an actual-waste Tank 38 sample. The HGR measurements at 80, 90, 100, and 110 °C were 1.7×10 -7 , 4.7×10 -7 , 5.9×10 -7 , and 2.6×10 -6 ft 3 hr -1 gal -1 , respectively. The Limit of Detection and Limit of Quantification for the HGR measurements were 2.6×10-8 ft3 hr-1 gal-1 and 5.1×10 -8 ft 3 hr -1 gal -1 , respectively. HGR was measured in a high boiling point (HBP) simulant with major known SRS Tank Farm organic compounds. Testing used fresh organics and did not simulate the long-term exposure of these organics already experienced in the waste. Hence, testing is expected to provide high bias to the hydrogen generation rates. The final HGR measurements at 75, 100, and 140 °C were 6.2×10 -7 , 3.0×10 -6 , and 8.1×10 -5 ft 3 hr -1 gal -1 , respectively. Decreases in the HGR were noted at isothermal conditions with steady gas tracer concentration, which clouds development of a temperature dependent correlation for generation rate. While the simulant contains high concentrations of major SRS organics tested at high temperatures found in the 3H Evaporator, this limited data set may not fully bound values under all possible operating conditions. The HGR measurement apparatus was successfully employed to replicate hydrogen production rate experiments. Simulant without deliberately added organic carbon was found to contain approximately 200 mg/L of organic carbon from tramp organics in the reagents used to prepare the solution. The tests using such simulant generated hydrogen at rates consistent with, but somewhat lower than, those predicted at equivalent carbon and aluminum loadings by methods used at the Hanford Site. Prior to identifying the organic contaminants, potential sources of hydrogen in simulants without deliberately added organic carbon were examined. Testing determined that this hydrogen is not due to caustic reaction of organic materials of construction within the reaction vessel, electrolysis due to current leak, anode/cathode reactions, corrosion, or the method of heating employed in the experiment. During the HBP and Tank 38 testing, a peak was identified at a retention time greater than the retention time of the inert tracer of krypton. This peak has been identified as methane, and the data have been reexamined to obtain methane concentrations. For the HBP testing, methane concentration was constant at the highest temperature studied (140 °C) and higher than hydrogen. At the lower temperatures (100 and 75 °C), methane and hydrogen tracked closely, with methane concentration generally lower than hydrogen. For Tank 38, methane concentration was approximately 1/3 of the hydrogen concentration during testing (100 and 110 °C). At lower temperatures for Tank 38 testing (90, 80, and 27 °C), methane fell below the quantification range.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NASA Human Spaceflight Scenarios - Do All Our Models Still Say No?

Historically, NASA human spaceflight planning has included healthy doses of life cycle cost analysis. Planners put projects and their cost estimates in a budget context. Estimated costs became expected budgets. Regardless, real budgets rarely matched expectations. So plans would come and go as NASA canceled projects. New projects would arise and the cycle would begin again. Repeatedly, NASA schedule and performance ambitions come up against costs growing at double-digit rates while budgets barely rise a couple of percent a year. Significant skepticism greets proposed NASA programs at birth, as cost estimates for new projects are traditionally very high, and worse, far off the mark for those carried forward. In this environment the current "capability driven framework" for NASA human spaceflight evolved, where long term life cycle cost analysis are even viewed as possibly counter-productive. Here, a space exploration project, for example the Space Launch System, focuses on immediate goals. A life cycle is that of a project, not a program, and for only that span of time to a near term milestone like a first test launch. Unfortunately, attempting to avoid some pitfalls in long-term life cycle cost analysis breeds others. Government audits have noted that limiting the scope of cost analysis "does not provide the transparency necessary to assess long-term affordability" making it difficult to understand if NASA "is progressing in a cost-effective and affordable manner." Even in this short-term framework, NASA realizes the importance of long-term considerations, that it must "maximize the efficiency and sustainability of the Exploration Systems development programs", that this is "critical to free resources for re-investment...such as other required deep space exploration capabilities." Assuming the value of long-term life cycle cost analysis, where due diligence meets reconnaissance, and accepting past shortcomings, the work here approaches life cycle cost analysis for human spaceflight differently. 1) If costs have traditionally been so high that adding them up is discouraging, are there any new facts on the ground offering paths to significantly lower costs? 2) If NASA's spaceflight budget and process is an over-arching constraint, with its planning limitations favoring short-term outlooks, is there a way to step outside the budget box? 3) If life cycle answers have historically been too uncertain to be useful, is there a process where stakeholders gain valuable insights merely from emphasizing a common understanding around questions? We analyze the potential life cycle cost of assorted NASA human spaceflight architectures - an architecture as a sum of individual systems, working together. With the prior questions of high costs, limited budgets and uncertainties in mind, public private partnerships are central in these architectures. The cost data for current commercial public private partnerships is encouraging, as are cost estimates for future partnership approaches beyond low Earth orbit. Private capital, directly or indirectly, an ingredient of public private partnerships, may be a significant factor in finding a path around the limits of the NASA spaceflight budget. Also, understanding and reviewing the pros, cons and uncertainties of assorted architectures can assist in developing a common understanding around key questions as important if not more so than the numbers and answers. Lastly, a scenario planning technique is briefly explored that can mature a common understanding about the agencies situation at hand and how diverse stakeholders can go forward together. Scenario planning, rather than focusing on answers, places emphasis on stakeholders developing a common understanding about the future. Putting aside costs, this is especially true of questions about sustainability and growth, results, benefits and expectations. While efficiency exercises or analysis look to reduce resources in one place to apply them elsewhere, moving around slices in a pie, scenario planning can get at the heart of the matter, growing the pie, transforming it, and making the pieces relevant. Especially important is the question of sustainability for different scenarios in the broad sense of the word - not just the narrow ability to survive or continue, but also the ability to adapt, prosper and grow.

space systems life cycle costs↗

Bio-regenerative life support

The basis for and the potential uses of bio-regenerative life support are examined. Bio-regenerative life support systems are an alternative to physical-chemical regeneration techniques for use when resupply of a crew in space is expensive, or when the logistics of resupply are difficult. Many of the scientific studies required for bio-regenerative life support systems have been completed and preliminary development of some components will begin within the next 12 to 18 months. The focus of the work that lies ahead will be efficient power and mass use, long-term system stability, component function, systems integration, and extensive testing in the space environment. Because of the advantages of bio-regeneration, it is anticipated that human life support for long-term space missions will evolve to include increasingly large amounts of biologically-based regeneration.

Macelroy, Robert D.↗