Search NASA⌕ Search

SEARCH · Search NASA

Results for “maximum likelihood”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

A Copula-Based Conditional Probabilistic Forecast Model for Wind Power Ramps

Efficient management of wind ramping characteristics can significantly reduce wind integration costs for balancing authorities. By considering the stochastic dependence of wind power ramp (WPR) features, this paper develops a conditional probabilistic wind power ramp forecast (cp-WPRF) model based on Copula theory. The WPRs dataset is constructed by extracting ramps from a large dataset of historical wind power. Each WPR feature (e.g., rate, magnitude, duration, and start-time) is separately forecasted by considering the coupling effects among different ramp features. To accurately model the marginal distributions with a copula, a Gaussian mixture model (GMM) is adopted to characterize the WPR uncertainty and features. The Canonical Maximum Likelihood (CML) method is used to estimate parameters of the multivariable copula. The optimal copula model is chosen based on the Bayesian information criterion (BIC) from each copula family. Finally, the best conditions based cp-WPRF model is determined by predictive interval (PI) based evaluation metrics. Numerical simulations on publicly available wind power data show that the developed copula-based cp-WPRF model can predict WPRs with a high level of reliability and sharpness.

17 WIND ENERGY↗

Joint Sparsity Pattern Recovery With 1-b Compressive Sensing in Distributed Sensor Networks

In this paper, we study the problem of joint sparse support recovery with 1-b quantized compressive measurements in a distributed sensor network. Multiple nodes in the network are assumed to observe sparse signals having the same but unknown sparse support. Each node quantizes its measurement vector element-wise to 1 b. First, we consider that all the quantized measurements are available at a central fusion center. We derive performance bounds for sparsity pattern recovery using 1-bit quantized measurements from multiple sensors when the maximum likelihood decoder is employed. We further develop two computationally tractable algorithms for joint sparse support recovery in the centralized setting. One algorithm minimizes a cost function defined as the sum of the likelihood function and the l-∝ quasi-norm, while the other algorithm extends the binary iterative hard thresholding algorithm to the multiple measurement vector case. Second, we consider a decentralized setting where each node transmits 1-b measurements to its one-hop neighbors. The basic idea behind the algorithms developed in the decentralized setting is to embed collaboration among nodes and fusion strategies. We show that even with noisy 1-b compressed measurements, joint support recovery can be carried out accurately in both centralized and decentralized settings. Additionally, we further show that the performance of the proposed 1-bit compressive sensing-based algorithms is very close to that of their real-valued counterparts except when the signal-to-noise ratio is very small.

97 MATHEMATICS AND COMPUTING↗

Genome-based evolutionary history of Pseudomonas spp

Pseudomonas is a large and diverse genus of Gammaproteobacteria. To provide a framework for discovery of evolutionary and taxonomic relationships of these bacteria, we compared the genomes of type strains of 163 species and 3 additional subspecies of Pseudomonas, including 118 genomes sequenced herein. A maximum likelihood phylogeny of the 166 type strains based on protein sequences of 100 single-copy orthologous genes revealed thirteen groups of Pseudomonas, composed of two to sixty three species each. Pairwise average nucleotide identities and alignment fractions were calculated for the data set of the 166 type strains and 1224 genomes of Pseudomonas available in public databases. Results revealed that 394 of the 1224 genomes were distinct from any type strain, suggesting that the type strains represent only a fraction of the genomic diversity of the genus. The core genome of Pseudomonas was determined to contain 794 genes conferring primarily housekeeping functions. Here, the results of this study provide a phylogenetic framework for future studies aiming to resolve the classification and phylogenetic relationships, identify new gene functions and phenotypes, and explore the ecological and metabolic potential of the Pseudomonas spp.

59 BASIC BIOLOGICAL SCIENCES↗

A Bayesian Approach for Extracting Fluorescence Lifetimes from Sparse Data Sets and Its Significance for Imaging Experiments

The measurement of fluorescence lifetimes, especially in small sample volumes, presents the dual challenge of probing a small number of fluorophores and fitting the concomitant sparse data set to the appropriate excited-state decay function. A common method of analysis, such as the maximum likelihood (ML) technique, assumes a uniform probability distribution of the parameters describing the fluorescence decay function. An improvement is thus suggested by implementing a suitable nonuniform distribution, as is provided by a Bayesian framework, where the distribution of parameters is obtained from both their prior knowledge and the evidence-based likelihood of an event for a given set of parameters. We have also considered the Dirichlet prior distribution, whose mathematical form enables analytical solutions of the fitting parameters to be rapidly obtained. If Gaussian and exponential prior distributions are judiciously chosen, they reproduce the experimental target lifetime to within 20% with as few as 20 total photon counts for the data set, as does the Dirichlet prior distribution. But because of the analytical solutions afforded by the Dirichlet prior distribution, it is proposed to employ a Dirichlet prior to search parameter space rapidly to provide, if necessary, appropriate parameters for subsequent employment of a Gaussian or exponential prior distribution

97 MATHEMATICS AND COMPUTING↗

Robust Solution Verification Experiments on Nonuniform Meshes

The activities of verification, validation, and uncertainty quantification (VVUQ) provide a comprehensive means to assess the credibility of computational models. Within VVUQ, solution verification assesses numerical errors and evaluates whether the simulation is sufficiently accurate for its intended applications. As computational modeling gains traction in the development of complex, high-consequence systems, the need for robust solution verification intensifies, particularly because experimental data for these systems are often limited. This work examines improvements in the robustness of Richardson extrapolation (RE), a method commonly used in solution verification to study the discretization error of computational models using a power law. Nonuniform mesh refinement is discussed alongside other pollutants that affect the robustness of the power law model. Maximum likelihood estimation (MLE) is proposed as a robust strategy to address the uncertainty generated by nonuniform mesh refinement. An exploratory computational fluid dynamics (CFD) study of a 2D planar Poiseuille flow is conducted to determine if nonuniform mesh noise can be modeled with this MLE approach for more robust RE.

Weinmeister, Justin [ORNL] (ORCID:0000000160090237↗

Degradation Modeling and Reliability Assessment of Capacitors

The degradation of capacitors under accelerated stress conditions occur in a monotonic and non-linear fashion. Several efforts have been made to model the degradation behavior of capacitor considering either physics-of-failure models or statistical models and subsequently estimate its reliability and lifetime parameters. But most of these models fail to reflect the physical properties of the degradation path, which varies according to several intrinsic and extrinsic factors. These factors introduce random and temporal uncertainty among the population of capacitors. The gamma stochastic process can model both type of uncertainties among the population of capacitors. In this paper, we model the capacitor degradation by non-homogeneous gamma stochastic process in which both the model parameters (shape and scale) are dependent on stress variables. The model parameters are estimated using the maximum likelihood estimation approach.

42 ENGINEERING↗

ESTIMATION OF CRACK-ARREST TOUGHNESS TRANSITION AND NDT TEMPERATURES FROM CHARPY FORCE-DISPLACEMENT IMPACT TRACES

A force-displacement trace of a Charpy impact test of a reactor pressure vessel (RPV) steel in the transition range has a characteristic point, the so-called force at the end of unstable crack propagation , Fa. A two-parameter Weibull probability function is used to model the distribution of the Fa in Charpy tests performed at ORNL on different RPV steels in the unirradiated and irradiated conditions. These data have a good replication at a given test temperature, thus, the statistical analysis was applicable. It is shown that when temperature is normalized to TNDT (T-TNDT) or to T100a (T-T100a), the median Fa values of different RPV steels have a tendency to form the same shape of temperature dependence. Depending on normalization temperature, TNDT or T100a, it suggests a universal shape of the temperature dependence of Fa for different RPV steels. The best fits for these temperature dependencies are presented. These dependencies are suggested for use in estimation of NDT or T100a from randomly generated Charpy impact tests. The maximum likelihood methods are used to derive equations to estimate TNDT and T100a from randomly generated Charpy impact tests.

Sokolov, Mikhail A↗

Evaluation of metal artifacts in MVCT systems using a model based correction method

Purpose: To evaluate the performance of a model based image reconstruction method in reducing metal artifacts in the megavoltage computed tomography (MVCT) images of a phantom representing bilateral hip prostheses and to compare with the filtered-backprojection (FBP) technique. Methods: An iterative maximum likelihood polychromatic algorithm for CT (IMPACT) is used with an additional model for the pair/triplet production process and the energy dependent response of the detectors. The beam spectra for an in-house bench-top and TomoTherapy Trade-Mark-Sign MVCTs are modeled for use in IMPACT. The empirical energy dependent response of detectors is calculated using a constrained optimization technique that predicts the measured attenuation of the beam by various thicknesses (0-24 cm) of solid water slabs. A cylindrical (19.1 cm diameter) plexiglass phantom containing various cylindrical inserts of relative electron densities 0.295-1.695 positioned between two steel rods (2.7 cm diameter) is scanned in the bench-top MVCT that utilizes the bremsstrahlung radiation from a 6 MeV electron beam passed through 4 cm solid water on the Varian Clinac 2300C and in the imaging beam of the TomoTherapy Trade-Mark-Sign MVCT. The FBP technique in bench-top MVCT reconstructs images from raw signal normalized to air scan and corrected for beam hardening using a uniform plexiglass cylinder (20 cm diameter). The IMPACT starts with a FBP reconstructed seed image and reconstructs the final image in 150 iterations. Results: In both MVCTs, FBP produces visible dark shading in the image connecting the steel rods. In the IMPACT reconstructed images this shading is nearly removed and the uniform background is restored. The average attenuation coefficients of the inserts and the background are very close to the corresponding values in the absence of the steel inserts. In the FBP images of the bench-top MVCT, the shading causes 4%-9.5% underestimation of electron density at the central inserts with an average of (6.3 {+-} 1.8)% for the range of electron densities studied. In the uniform plexiglass background, the shadow creates 0.8%-4.7% underestimation of electron density with an average of (2.9 {+-} 1.2)%. In the corresponding IMPACT images, the underestimation in the shaded plexiglass background is 0.3%-1.8% with an average of (0.9 {+-} 0.5)% and 1.4%-6.8% with an average of (2.8 {+-} 2.7)% in the central insert region. In the FBP images of the TomoTherapy Trade-Mark-Sign MVCT, this shading creates 2.6%-6.7% underestimation of electron density with an average of (3.7 {+-} 1.4)% at the central inserts and 5.9%-7.2% underestimation in the background with an average of (6.4 {+-} 0.5)%. In the IMPACT images, the uniform background between the steel rods is restored with 0.3%-1.0% underestimation of electron density with an average of (0.7 {+-} 0.3)%. The corresponding underestimation at the central inserts of the IMPACT images is -0.4%-0.1% with an average of (-0.1 {+-} 0.2)%. Conclusions: The shading metal artifact has been nearly removed in MVCT images using the IMPACT algorithm with the accurate geometry of the system, proper modeling of energy dependent response of detectors, and all relevant photon interaction processes. This results less than 1% difference in electron density in the background plexiglass and less than 3% averaged over the range of electron densities investigated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of normalized metal artifact reduction (NMAR) in kVCT using MVCT prior images for radiotherapy treatment planning

Purpose: To evaluate the metal artifacts in kilovoltage computed tomography (kVCT) images that are corrected using a normalized metal artifact reduction (NMAR) method with megavoltage CT (MVCT) prior images.Methods: Tissue characterization phantoms containing bilateral steel inserts are used in all experiments. Two MVCT images, one without any metal artifact corrections and the other corrected using a modified iterative maximum likelihood polychromatic algorithm for CT (IMPACT) are translated to pseudo-kVCT images. These are then used as prior images without tissue classification in an NMAR technique for correcting the experimental kVCT image. The IMPACT method in MVCT included an additional model for the pair/triplet production process and the energy dependent response of the MVCT detectors. An experimental kVCT image, without the metal inserts and reconstructed using the filtered back projection (FBP) method, is artificially patched with the known steel inserts to get a reference image. The regular NMAR image containing the steel inserts that uses tissue classified kVCT prior and the NMAR images reconstructed using MVCT priors are compared with the reference image for metal artifact reduction. The Eclipse treatment planning system is used to calculate radiotherapy dose distributions on the corrected images and on the reference image using the Anisotropic Analytical Algorithm with 6 MV parallel opposed 5 × 10 cm{sup 2} fields passing through the bilateral steel inserts, and the results are compared. Gafchromic film is used to measure the actual dose delivered in a plane perpendicular to the beams at the isocenter.Results: The streaking and shading in the NMAR image using tissue classifications are significantly reduced. However, the structures, including metal, are deformed. Some uniform regions appear to have eroded from one side. There is a large variation of attenuation values inside the metal inserts. Similar results are seen in commercially corrected image. Use of MVCT prior images without tissue classification in NMAR significantly reduces these problems. The radiation dose calculated on the reference image is close to the dose measured using the film. Compared to the reference image, the calculated dose difference in the conventional NMAR image, the corrected images using uncorrected MVCT image, and IMPACT corrected MVCT image as priors is ∼15.5%, ∼5%, and ∼2.7%, respectively, at the isocenter.Conclusions: The deformation and erosion of the structures present in regular NMAR corrected images can be largely reduced by using MVCT priors without tissue segmentation. The attenuation value of metal being incorrect, large dose differences relative to the true value can result when using the conventional NMAR image. This difference can be significantly reduced if MVCT images are used as priors. Reduced tissue deformation, better tissue visualization, and correct information about the electron density of the tissues and metals in the artifact corrected images could help delineate the structures better, as well as calculate radiation dose more correctly, thus enhancing the quality of the radiotherapy treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preliminary investigations on the determination of three-dimensional dose distributions using scintillator blocks and optical tomography

Purpose: Clinical QA in teletherapy as well as the characterization of experimental radiation sources for future medical applications requires effective methods for measuring three-dimensional (3D) dose distributions generated in a water-equivalent medium. Current dosimeters based on ionization chambers, diodes, thermoluminescence detectors, radiochromic films, or polymer gels exhibit various drawbacks: High quality 3D dose determination is either very sophisticated and expensive or requires high amounts of effort and time for the preparation or read out. New detectors based on scintillator blocks in combination with optical tomography are studied, since they have the potential to facilitate the desired cost-effective, transportable, and long-term stable dosimetry system that is able to determine 3D dose distributions with high spatial resolution in a short time.Methods: A portable detector prototype was set up based on a plastic scintillator block and four digital cameras. During irradiation the scintillator emits light, which is detected by the fixed cameras. The light distribution is then reconstructed by optical tomography, using maximum-likelihood expectation maximization. The result of the reconstruction approximates the 3D dose distribution. First performance tests of the prototype using laser light were carried out. Irradiation experiments were performed with ionizing radiation, i.e., bremsstrahlung (6 to 21 MV), electrons (6 to 21 MeV), and protons (68 MeV), provided by clinical and research accelerators.Results: Laser experiments show that the current imaging properties differ from the design specifications: The imaging scale of the optical systems is position dependent, ranging from 0.185 mm/pixel to 0.225 mm/pixel. Nevertheless, the developed dosimetry method is proven to be functional for electron and proton beams. Induced radiation doses of 50 mGy or more made 3D dose reconstructions possible. Taking the imaging properties into account, determined dose profiles are in agreement with reference measurements. An inherent drawback of the scintillator is the nonlinear light output for high stopping-power radiation due to the quenching effect. It impacts the depth dose curves measured with the dosimeter. For single Bragg peak distributions this leads to a peak to plateau ratio of 2.8 instead of 4.5 for the reference ionization chamber measurement. Furthermore, the transmission of the clinical bremsstrahlung beams through the scintillator leads to the saturation of one camera, making dose reconstructions in that case presently not feasible.Conclusions: It is shown that distributions of scintillation light generated by proton or electron beams can be reconstructed by the dosimetry system within minutes. The quenching apparent for proton irradiation, and the yet not precisely determined position dependency of the imaging scale, require further investigation and corrections. Upgrading the prototype with larger or inorganic scintillators would increase the detectable proton and electron energy range. The presented results show that the determination of 3D dose distributions using scintillator blocks and optical tomography is a promising dosimetry method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a constrained paired-view technique in iterative reconstruction for breast tomosynthesis

Purpose: The order in which the projection views are employed in the reconstruction of tomosynthesis by iterative algorithms, such as simultaneous algebraic reconstruction technique and maximum likelihood, has a strong effect on the rate of convergence, accuracy, and the edge-blurring artifacts in the reconstructed image. The purpose of this investigation was to characterize and evaluate the effects of ordering schemes on image quality for breast tomosynthesis reconstruction and to explore a new constrained paired-view technique that could provide reduction of reconstruction artifacts. In this work, the authors compared several different ordering schemes and characterized the image quality and the formation of out-of-plane artifacts. Furthermore, a new normalization method is presented. It produces more accurate reconstructions with reduced artifacts comparing to the standard method of sequential ordering.Methods: In addition to visual assessment of image quality, several indices such as the signal-difference-to-noise ratio, the artifact-spread function, and the lesion detectability (d{sup ′}) were computed to quantitatively evaluate the effect of ordering scheme. The sets of breast tomosynthesis projection images were simulated for reconstruction; one set had uniform background (white noise only) and the other two contained both anatomic background and quantum noise. Clinical breast images were also studied for comparison.Results: The authors have quantified the image quality in reconstructed slices for a range of tumor sizes. The authors’ proposed method provides better performance for all of the metrics tested (contrast, d{sup ′}, and the level of artifacts) both for the uniform phantom case and in the presence of anatomical structure.Conclusions: The paired projection normalization provides better performance in the image quality of the reconstructed slices, and results in a lower level of artifacts in the Z direction. This implies that even a relatively simple method like the “side-to-side” sequence, which pairs two symmetrical projections with equal angular distance from the central projection, would achieve better reconstructed image quality than the conventional “step-by-step” method, which uses sequential projections one after another.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-399: Determination of the Radiobiological Parameters That Describe the Dose-Response Relations of Xerostomia and Disgeusia From Head and Neck Radiotherapy

Purpose: To estimate the radiobiological parameters that describe the doseresponse relations of xerostomia and disgeusia from head and neck cancer radiotherapy. To identify the organs that are best correlated with the manifestation of those clinical endpoints. Finally, to evaluate the goodnessof- fit by comparing the model predictions against the actual clinical results. Methods: In this study, 349 head and neck cancer patients were included. For each patient the dose volume histograms (DVH) of parotids (separate and combined), mandible, submandibular glands (separate and combined) and salivary glands were calculated. The follow-up of those patients was recorded at different times after the completion of the treatment (7 weeks, 3, 7, 12, 18 and 24 months). Acute and late xerostomia and acute disgeusia were the clinical endpoints examined. A maximum likelihood fitting was performed to calculate the best estimates of the parameters used by the relative seriality model. The statistical methods of the error distribution, the receiver operating characteristic (ROC) curve, the Pearson's test and the Akaike's information criterion were utilized to assess the goodness-of-fit and the agreement between the pattern of the radiobiological predictions with that of the clinical records. Results: The estimated values of the radiobiological parameters of salivary glands are D50 = 25.2 Gy, γ = 0.52, s = 0.001. The statistical analysis confirmed the clinical validity of those parameters (area under the ROC curve = 0.65 and AIC = 38.3). Conclusion: The analysis proved that the treatment outcome pattern of the patient material can be reproduced by the relative seriality model and the estimated radiobiological parameters. Salivary glands were found to have strong volume dependence (low relative seriality). Diminishing the biologically effective uniform dose to salivary glands below 30 Gy may significantly reduce the risk of complications to the patients irradiated for prostate cancer.

60 APPLIED LIFE SCIENCES↗

Side readout of long scintillation crystal elements with digital SiPM for TOF-DOI PET

Purpose: Side readout of scintillation light from crystal elements in positron emission tomography (PET) is an alternative to conventional end-readout configurations, with the benefit of being able to provide accurate depth-of-interaction (DOI) information and good energy resolution while achieving excellent timing resolution required for time-of-flight PET. This paper explores different readout geometries of scintillation crystal elements with the goal of achieving a detector that simultaneously achieves excellent timing resolution, energy resolution, spatial resolution, and photon sensitivity. Methods: The performance of discrete LYSO scintillation elements of different lengths read out from the end/side with digital silicon photomultipliers (dSiPMs) has been assessed. Results: Compared to 3 × 3 × 20 mm{sup 3} LYSO crystals read out from their ends with a coincidence resolving time (CRT) of 162 ± 6 ps FWHM and saturated energy spectra, a side-readout configuration achieved an excellent CRT of 144 ± 2 ps FWHM after correcting for timing skews within the dSiPM and an energy resolution of 11.8% ± 0.2% without requiring energy saturation correction. Using a maximum likelihood estimation method on individual dSiPM pixel response that corresponds to different 511 keV photon interaction positions, the DOI resolution of this 3 × 3 × 20 mm{sup 3} crystal side-readout configuration was computed to be 0.8 mm FWHM with negligible artifacts at the crystal ends. On the other hand, with smaller 3 × 3 × 5 mm{sup 3} LYSO crystals that can also be tiled/stacked to provide DOI information, a timing resolution of 134 ± 6 ps was attained but produced highly saturated energy spectra. Conclusions: The energy, timing, and DOI resolution information extracted from the side of long scintillation crystal elements coupled to dSiPM have been acquired for the first time. The authors conclude in this proof of concept study that such detector configuration has the potential to enable outstanding detector performance in terms of timing, energy, and DOI resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recovery and normalization of triple coincidences in PET

Purpose: Triple coincidences in positron emission tomography (PET) are events in which three γ-rays are detected simultaneously. These events, though potentially useful for enhancing the sensitivity of PET scanners, are discarded or processed without special consideration in current systems, because there is not a clear criterion for assigning them to a unique line-of-response (LOR). Methods proposed for recovering such events usually rely on the use of highly specialized detection systems, hampering general adoption, and/or are based on Compton-scatter kinematics and, consequently, are limited in accuracy by the energy resolution of standard PET detectors. In this work, the authors propose a simple and general solution for recovering triple coincidences, which does not require specialized detectors or additional energy resolution requirements. Methods: To recover triple coincidences, the authors’ method distributes such events among their possible LORs using the relative proportions of double coincidences in these LORs. The authors show analytically that this assignment scheme represents the maximum-likelihood solution for the triple-coincidence distribution problem. The PET component of a preclinical PET/CT scanner was adapted to enable the acquisition and processing of triple coincidences. Since the efficiencies for detecting double and triple events were found to be different throughout the scanner field-of-view, a normalization procedure specific for triple coincidences was also developed. The effect of including triple coincidences using their method was compared against the cases of equally weighting the triples among their possible LORs and discarding all the triple events. The authors used as figures of merit for this comparison sensitivity, noise-equivalent count (NEC) rates and image quality calculated as described in the NEMA NU-4 protocol for the assessment of preclinical PET scanners. Results: The addition of triple-coincidence events with the authors’ method increased peak NEC rates of the scanner by 26.6% and 32% for mouse- and rat-sized objects, respectively. This increase in NEC-rate performance was also reflected in the image-quality metrics. Images reconstructed using double and triple coincidences recovered using their method had better signal-to-noise ratio than those obtained using only double coincidences, while preserving spatial resolution and contrast. Distribution of triple coincidences using an equal-weighting scheme increased apparent system sensitivity but degraded image quality. The performance boost provided by the inclusion of triple coincidences using their method allowed to reduce the acquisition time of standard imaging procedures by up to ∼25%. Conclusions: Recovering triple coincidences with the proposed method can effectively increase the sensitivity of current clinical and preclinical PET systems without compromising other parameters like spatial resolution or contrast.

60 APPLIED LIFE SCIENCES↗

TU-F-CAMPUS-I-02: Contrast Enhanced Cone Beam CT Imaging with Dual- Gantry Image Acquisition and Constrained Iterative Reconstruction-a Simulation Study for Liver Imaging Application

Purpose: Contrast time-density curves may help differentiate malignant tumors from normal tissues or benign tumors. Repetitive scans using conventional CT or cone beam CT techniques, which Result in unacceptably high dose, may not achieve the desired temporal resolution. In this study we describe and demonstrate a 4D imaging technique for imaging and quantifying contrast flows requiring only one or two 360° scans. Methods: A dual-gantry system is used to simultaneously acquire two projection images at orthogonal orientations. Following the scan, each or both of the two 360° projection sets are used to reconstruct an average contrast enhanced image set which is then segmented to form a 3D contrast map. Alternatively, a pre-injection scan may be made and used to reconstruct a pre-injection image set which is subtracted from the post-injection image set to form the 3D contrast map. Each of the two 360° projection sets is divided into 12 subsets, thus creating 12 pairs of 30° limited angle projection sets, each corresponding to a time spanning over 1/12 of the scanning time. Each pair of the projection sets are reconstructed as a time specific 3D image set with the maximum likelihood estimation iterative algorithm using the contrast map as the constraint. As a demonstration, a 4D abdominal phantom was constructed from clinical CT images with blood flow through the normal tissue and a tumor modeled and imaging process simulated. Results: We have successfully generated a 4D image phantom, and calculated the projection images. The time density curves derived from the reconstructed image set matched well with the flow model used to generate the phantom. Conclusion: Dual-gantry image acquisition and constrained iterative reconstruction algorithm may help to obtain time-density curves of contrast agents in blood flows, which may help differentiate malignant tumors from normal tissues or benign tumors.

60 APPLIED LIFE SCIENCES↗

A dual-view digital tomosynthesis imaging technique for improved chest imaging

Purpose: Digital tomosynthesis (DTS) has been shown to be useful for reducing the overlapping of abnormalities with anatomical structures at various depth levels along the posterior–anterior (PA) direction in chest radiography. However, DTS provides crude three-dimensional (3D) images that have poor resolution in the lateral view and can only be displayed with reasonable quality in the PA view. Furthermore, the spillover of high-contrast objects from off-fulcrum planes generates artifacts that may impede the diagnostic use of the DTS images. In this paper, the authors describe and demonstrate the use of a dual-view DTS technique to improve the accuracy of the reconstructed volume image data for more accurate rendition of the anatomy and slice images with improved resolution and reduced artifacts, thus allowing the 3D image data to be viewed in views other than the PA view. Methods: With the dual-view DTS technique, limited angle scans are performed and projection images are acquired in two orthogonal views: PA and lateral. The dual-view projection data are used together to reconstruct 3D images using the maximum likelihood expectation maximization iterative algorithm. In this study, projection images were simulated or experimentally acquired over 360° using the scanning geometry for cone beam computed tomography (CBCT). While all projections were used to reconstruct CBCT images, selected projections were extracted and used to reconstruct single- and dual-view DTS images for comparison with the CBCT images. For realistic demonstration and comparison, a digital chest phantom derived from clinical CT images was used for the simulation study. An anthropomorphic chest phantom was imaged for the experimental study. The resultant dual-view DTS images were visually compared with the single-view DTS images and CBCT images for the presence of image artifacts and accuracy of CT numbers and anatomy and quantitatively compared with root-mean-square-deviation (RMSD) values computed using the digital chest phantom or the CBCT images as the reference in the simulation and experimental study, respectively. High-contrast wires with vertical, oblique, and horizontal orientations in a PA view plane were also imaged to investigate the spatial resolutions and how the wire signals spread in the PA view and lateral view slice images. Results: Both the digital phantom images (simulated) and the anthropomorphic phantom images (experimentally generated) demonstrated that the dual-view DTS technique resulted in improved spatial resolution in the depth (PA) direction, more accurate representation of the anatomy, and significantly reduced artifacts. The RMSD values corroborate well with visual observations with substantially lower RMSD values measured for the dual-view DTS images as compared to those measured for the single-view DTS images. The imaging experiment with the high-contrast wires shows that while the vertical and oblique wires could be resolved in the lateral view in both single- and dual-view DTS images, the horizontal wire could only be resolved in the dual-view DTS images. This indicates that with single-view DTS, the wire signals spread liberally to off-fulcrum planes and generated wire shadow there. Conclusions: The authors have demonstrated both visually and quantitatively that the dual-view DTS technique can be used to achieve more accurate rendition of the anatomy and to obtain slice images with improved resolution and reduced artifacts as compared to the single-view DTS technique, thus allowing the 3D image data to be viewed in views other than the PA view. These advantages could make the dual-view DTS technique useful in situations where better separation of the objects-of-interest from the off-fulcrum structures or more accurate 3D rendition of the anatomy are required while a regular CT examination is undesirable due to radiation dose considerations.

60 APPLIED LIFE SCIENCES↗

Segmented slant hole collimator for stationary cardiac SPECT: Monte Carlo simulations

Purpose: This work is a preliminary study of a stationary cardiac SPECT system. The goal of this research is to propose a stationary cardiac SPECT system using segmented slant-hole collimators and to perform computer simulations to test the feasibility. Compared to the rotational SPECT, a stationary system has a benefit of acquiring temporally consistent projections. The most challenging issue in building a stationary system is to provide sufficient projection view-angles. Methods: A GATE (GEANT4 application for tomographic emission) Monte Carlo model was developed to simulate a two-detector stationary cardiac SPECT that uses segmented slant-hole collimators. Each detector contains seven segmented slant-hole sections that slant to a common volume at the rotation center. Consequently, 14 view-angles over 180° were acquired without any gantry rotation. The NCAT phantom was used for data generation and a tailored maximum-likelihood expectation-maximization algorithm was used for image reconstruction. Effects of limited number of view-angles and data truncation were carefully evaluated in the paper. Results: Simulation results indicated that the proposed segmented slant-hole stationary cardiac SPECT system is able to acquire sufficient data for cardiac imaging without a loss of image quality, even when the uptakes in the liver and kidneys are high. Seven views are acquired simultaneously at each detector, leading to 5-fold sensitivity gain over the conventional dual-head system at the same total acquisition time, which in turn increases the signal-to-noise ratio by 19%. The segmented slant-hole SPECT system also showed a good performance in lesion detection. In our prototype system, a short hole-length was used to reduce the dead zone between neighboring collimator segments. The measured sensitivity gain is about 17-fold over the conventional dual-head system. Conclusions: The GATE Monte Carlo simulations confirm the feasibility of the proposed stationary cardiac SPECT system with segmented slant-hole collimators. The proposed collimator consists of combined parallel and slant holes, and the image on the detector is not reduced in size.

60 APPLIED LIFE SCIENCES↗