Search NASA⌕ Search

SEARCH · Search NASA

Results for “millimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

High power, high efficiency millimeter wavelength traveling wave tubes for high rate communications from deep space

The high-power transmitters needed for high data rate communications from deep space will require a new class of compact, high efficiency traveling wave tubes (TWT's). Many of the recent TWT developments in the microwave frequency range are generically applicable to mm wave devices, in particular much of the technology of computer aided design, cathodes, and multistage depressed collectors. However, because TWT dimensions scale approximately with wavelength, mm wave devices will be physically much smaller with inherently more stringent fabrication tolerances and sensitivity to thermal dissipation.

Dayton, James A., Jr.↗

A wide-band monolithic quasi-optical power meter for millimeter- and submillimeter-wave applications

A novel monolithic power meter has been developed for submillimeter-wave applications (100 GHz to 10 THz). The detector is a large-area bismuth bolometer integrated on a 1.2-micron-thick dielectric membrane. This approach results in a wide-band, high-responsivity detector. The power meter is simple to fabricate, is inexpensive, and can be easily calibrated using a low-frequency network. Quasi-optical measurements at 90, 140, and 240 GHz show that the bolometer is polarization-independent and could be modeled by a simple transmission line model. Absolute power measurements at 90, 140, and 240 GHz show a + or - 5 percent accuracy and agree well with a calibrated Anritsu power meter at 90 GHz. Potential application areas are power calibration, antenna coupling efficiency measurements, and absolute power measurements from solid-state devices and far-infrared lasers at submillimeter wavelengths. Absolute output power measurements on a 220-280 GHz tripler using the quasi-optical power meter are presented as an application example.

Ling, Curtis C.↗

YBCO superconducting ring resonators at millimeter-wave frequencies

Microstrip ring resonators operating at 35 GHz were fabricated from laser ablated YBCO films deposited on lanthanum aluminate substrates. They were measured over a range of temperatures and their performances compared to identical resonators made of evaporated gold. Below 60 Kelvin the superconducting strip performed better than the gold, reaching an unloaded Q approximately 1.5 times that of gold at 25 K. A shift in the resonant frequency follows the form predicted by the London equations. The Phenomenological Loss Equivalence Method is applied to the ring resonator and the theoretically calculated Q values are compared to the experimental results.

Chorey, Christopher M.↗

Variable temperature pressure broadening of HNO3 in the millimeter wave spectral region

Measurements were performed for both O2 and N2 broadening in the 100-380 K temperature range by using a heated equilibrium cell for elevated temperatures and the utilization of a collisionally cooled cell at the lower temperatures where HNO3 has a small vapor pressure. Observed pressure-broadening data can be fit to the normal empirical law, giving n values between 0.62 and 0.84.

Goyette, Thomas M.↗

Development of theoretical models of integrated millimeter wave antennas

Extensive radiation patterns for Linear Tapered Slot Antenna (LTSA) Single Elements are presented. The directivity of LTSA elements is predicted correctly by taking the cross polarized pattern into account. A moment method program predicts radiation patterns for air LTSAs with excellent agreement with experimental data. A moment method program was also developed for the task LTSA Array Modeling. Computations performed with this program are in excellent agreement with published results for dipole and monopole arrays, and with waveguide simulator experiments, for more complicated structures. Empirical modeling of LTSA arrays demonstrated that the maximum theoretical element gain can be obtained. Formulations were also developed for calculating the aperture efficiency of LTSA arrays used in reflector systems. It was shown that LTSA arrays used in multibeam systems have a considerable advantage in terms of higher packing density, compared with waveguide feeds. Conversion loss of 10 dB was demonstrated at 35 GHz.

Yngvesson, K. Sigfrid↗

Goddard Space Flight Center specification for Helical-Scan 8-millimeter (mm) magnetic digital data tape cartridge

The same kind of standard and controls are established that are currently in use for the procurement of new analog, digital, and IBM/IBM compatible 3480 tape cartridges, and 1 in wide channel video magnetic tapes. The Magnetic Tape Certification Facility (MTCF) maintains a Qualified Products List (QPL) for the procurement of new magnetic media and uses the following specifications for the QPL and Acceptance Tests: (1) NASA TM-79724 is used for the QPL and Acceptance Testing of new analog magnetic tapes; (2) NASA TM-80599 is used for the QPL and Acceptance Testing of new digital magnetic tapes; (3) NASA TM-100702 is used for the QPL and Acceptance Testing of new IBM/IBM compatible 3840 magnetic tape cartridges; and (4) NASA TM-100712 is used for the QPL and Acceptance Testing of new 1 in wide channel video magnetic tapes. This document will be used for the QPL and Acceptance Testing of new Helical Scan 8 mm digital data tape cartridges.

Perry, Jimmy L.↗

Commercial applications of the ACTS mobile terminal millimeter-wave antennas

NASA's Jet Propulsion Laboratory is currently developing the Advanced Communications Technology Satellite (ACTS) Mobile Terminal (AMT), which will provide voice, data, and video communications to and from a vehicle (van, truck, or car) via NASA's geostationary ACTS satellite using the K- and K(sub a)-band frequency bands. The AMT is already planned to demonstrate a variety of communications from within the mobile vehicular environment, and within this paper a summary of foreseen commercial application opportunities is given. A critical component of the AMT is its antenna system, which must establish and maintain the basic RF link with the satellite. Two versions of the antenna are under development, each incorporating different technologies and offering different commercial applications.

Densmore, Arthur C.↗

A millimeter wave technique for measuring ice thickness on the Space Shuttle's external tank

A solution is presented for detecting and measuring ice that can form on the spray-on foam insulation protecting Space Shuttle fueltanks. The method involves the measurement of the emission properties of the fueltank with a mm-wave radiometer. Emission from the insulated panel is measured for the case of insulation with the original rough surface and the case of insulation sanded down to have a smooth surface. The radiative transfer calculations are facilitated by using a smooth surface, and experimental evidence demonstrates the effective and accurate prediction of ice thickness on the smooth surface. The panel with a rough surface is measured, and the emmision levels are higher than those predicted by model calculations. Sensitivity to ice thickness is similar in both situations in spite of the bias introduced by the rough surface.

Kendra, John E.↗

Angstrom level profilometry for sub-millimeter to meter scale surface errors

A versatile noncontacting profilimetry approach is defined which involves the measurement of the local curvature of a test piece by simultaneously measuring its slope at two slightly displaced locations. Several extensions of the measurement technique are emphasized including beam expansion for long scans, measurement of circularity and cone angle of near cylindrical optics, and measurement of absolute flatness.

Glenn, Paul↗

Infrared dust and millimeter-wave carbon monoxide emission in the Orion region

The far-infrared dust emission seen by the IRAS satellite in the Orion region is analyzed as a function of the local radiation field intensity, and the dust temperature and opacity are compared with (C-12)O and (C-13)O emission. The infrared radiation is interpreted within the framework of a single-component large grain model and a multicomponent grain model consisting of subpopulations of grains with size-dependent temperatures. A strong dependence of the 100-micron optical depth derived is found using the large grain model on the average line-of-sight dust temperature and radiation field. In the hot environment surrounding high-luminosity sources and H II regions, all dust along the line-of-sight radiates at 100 microns, and the dust-to-gas ratio, based on the 100-micron opacity and I(/C-13/O), appears to be in agreement with the standard value, about 1 percent by mass. A relationship is found between the inferred dust-to-gas ratio and the radiation field intensity responsible for heating the dust which can be used to estimate the gas column density from the dust opacity derived from the 60- and 100-micron IRAS fluxes.

Bally, John↗

The molecular core in G34.3 + 0.2 - Millimeter interferometric observations of HCO(+), H(C-13)N, H(C-15)N, and SO

This study presents high-resolution observations of the molecular core in the star-forming region G34.3 + 0.2. Maps at 6-arcsec resolution of emission and absorption of the J = 1 - 0 transitions of HCO(+), H (C-13)N, H(C-15)N, and of the 2(2) - 1(1) transition of SO were obtained in addition to a map of the 3.4-mm continuum emission from the compact H II component. The HCL(+) emission toward G34.3 + 0.2 traces a warm molecular core about 0.9 pc in size. Emission from H (C-13)N is detected over about 0.3 pc. The cometary H II region lies near the edge of the molecular core. The blueshift of the radio recombination lines with respect to the molecular emission suggests that gas from the H II region is accelerated in a champagne flow caused by a steep gradient in the ambient gas density.

Carral, Patricia↗

An evaluation of HEMT potential for millimeter-wave signal sources using interpolation and harmonic balance techniques

A large-signal analysis method based on an harmonic balance technique and a 2-D cubic spline interpolation function has been developed and applied to the prediction of InP-based HEMT oscillator performance for frequencies extending up to the submillimeter-wave range. The large-signal analysis method uses a limited number of DC and small-signal S-parameter data and allows the accurate characterization of HEMT large-signal behavior. The method has been validated experimentally using load-pull measurement. Oscillation frequency, power performance, and load requirements are discussed, with an operation capability of 300 GHz predicted using state-of-the-art devices (fmax is approximately equal to 450 GHz).

Kwon, Youngwoo↗

Millimeter-wave integrated-horn antennas. I - Theory. II - Experiment

Full-wave analysis is employed to determine the far-field pattern and input impedance of a dipole-fed horn antenna in a ground plane, and the theoretical results are compared with mm-wave and microwave data. The theoretical work exploits the Green's function corresponding to the horn structure and the method of moments. It is determined that the horn should have 70 sections/wavelength and 50 secondary modes for optimized accuracy, and certain dipole positions can reduce the resonance to zero. The experimentally derived impedance and radiation patterns agree with the constraints developed theoretically. The 70-degree flare-angle horn with selected dipole positions and horn apertures yields good radiation patterns, cross-polarization levels, and resonant dipole impedances. The conclusions are of interest to the development of the horn antennas etched in Si/GaAs for applications to zero-visibility tracking, radio astronomy, plasma diagnostics, and remote sensing.

Eleftheriades, George V.↗

Characterization of resonant tunneling diodes for microwave and millimeter-wave detection

The authors report on the direct detection capabilities of resonant tunneling diodes in the 10-100 GHz range. An open circuit voltage sensitivity of 1750 mV/mW (in Ka-band) was measured. This is higher than the sensitivity of comparatively based commercially available solid-state detectors. The detector properties are a strong function of diode bias and the measured tangential signal sensitivity (-32 dBm at Ka-band with 1-MHz bandwidth) and the dynamic range (25 dB) of the diode are smaller compared to other solid-state detectors.

Mehdi, I.↗

Integrated horn antennas for millimeter-wave applications

The development of integrated horn antennas since their introduction in 1987 is reviewed. The integrated horn is fabricated by suspending a dipole antenna, on a thin dielectric membrane, in a pyramidal cavity etched in silicon. Recent progress has resulted in optimized low- and high-gain designs, with single and double polarization for remote-sensing and communication applications. A full-wave analysis technique has resulted in an integrated antenna with performance comparable to that of waveguide-fed corrugated-horn antennas. The integrated horn design can be extended to large arrays, for imaging and phased-array applications, while leaving plenty of room for the RF and IF processing circuitry. Theoretical and experimental results at microwave frequencies and at 90 GHz, 240 GHz, and 802 GHz are presented.

Rebeiz, Gabriel M.↗

A bolometric millimeter-wave system for observations of anisotropy in the cosmic microwave background radiation on medium angular scales

The performance of a bolometric system designed to measure the anisotropy of the cosmic microwave background (CMB) radiation on angular scales from 0.3 to 3 deg is presented. The system represents a collaborative effort combining a low-background 1-m diameter balloon-borne telescope with new multimode feed optics, a beam modulation mechanism with high stability, and a four-channel bolometric receiver with passbands centered near frequencies of 3, 6, 9, and 12/cm (90, 180, 270, and 360 GHz). The telescope has been flown three times with the bolometric receiver and has demonstrated detector noise limited performance capable of reaching sensitivity levels of about 0.00001 with detectors operated at 0.3 K.

Fischer, M. L.↗

Search for sulfur (H2S) on Jupiter at millimeter wavelengths

Jupiter was observed at two wavelengths near 1.4 mm in an attempt to detect gaseous hydrogen sulfide (H2S) or place new upper limits on its abundance on Jupiter's atmosphere. Although no H2S was detected, the first brightness temperature observations of Jupiter at 1.4 mm are reported with a spectral resolution of approximately 1 GHz using Mars as a calibration standard. The methodology and results of a laboratory experiment in which H2S absorption at 1.4 mm was measured in a simulated Jovian atmosphere. The results of laboratory measurements are applied to a radiative transfer model which is used to interpret the observations of Jupiter.

Joiner, Joanna↗