Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Active Measurement of Plasma Parameters in Over-Dense MFE Reactor Plasma Using High Frequency Beat-Wave Resonantly Generated Thermal Bernstein Waves

UC Davis was funded to explore the combination of beat-wave excitation and laser scattering to make completely non-invasive determination of local plasma conditions. This involves the use of two high frequency mm-wave sources of differing frequencies (the pump waves) to excite plasma waves at the difference of the frequencies, which is known as the beat frequency. The difference frequency or the frequency of the beat wave is chosen so that we produce plasma waves whose fluctuating electron density is a sensitive function of plasma parameters at the location where the source waves overlap. This fluctuation can be detected from outside the plasma, by measuring the deflection of a probe beam directed at the overlap region between the two pump waves (i.e., collective scattering). This work is an extension of mm-wave frequencies of a 10 GHz beat-wave experiment conducted on the DDT toroidal device (see Fig. 1) in a magnetized plasma where the excited Langmuir wave is replaced by the magnetized upper hybrid wave. Here, two high power (> 1 kW) ~94 GHz pump sources will be employed to match the upper hybrid resonance. The primary envisioned experiment is to drive the electron Bernstein wave (EBW) in the interior of a magnetized plasma. The EBW is a hot-plasma electrostatic wave, which cannot propagate in vacuum. Roots of the EBW dispersion relation occur at frequencies slightly higher than harmonics of the electron cyclotron frequency. Use of the EBW has particular advantages for measuring plasma magnetic field in plasmas with relatively high density and low magnetic field, as is the case in spherical tokamaks. This is the “over dense” condition of future efficient high beta magnetic confinement fusion reactors such as the spherical tokamak (STs). The overarching goal of the proposed project is to demonstrate beat wave EBW excitation in low density and temperature parameters that are directly scalable to over-dense spherical tokamaks such as NSTX or MAST, where measurement of magnetic field by electron cyclotron emission (ECE) is experimentally complex, and requires models of plasma profiles in order to interpret results. In such experiments, availability of point measurements of magnetic field strength provided by a beat-wave diagnostic would serve as a powerful independent check on the ECE results, serving to validate the assumed profiles and wave-propagation models used. The first step was to assemble/modify the target chamber in which the beat-wave plasma experiments will take place. Here, the target chamber of the CTIX compact-toroid (spheromak) injector was chosen. At the time that the proposal was submitted, the aim was to conduct the experiments in the CTIX experimental facilities located at the Livermore campus of UC Davis using microwave/mm-wave equipment brought from the main campus., However, by the time DoE funds for this project were awarded, the CTIX experimental facilities located at the Livermore campus of UC Davis were in the process of being shut down due to the closure of the Livermore campus by Lawrence Livermore National Laboratory (LLNL). Consequently, the equipment needed for this project was crated up and shipped from Livermore to Davis as part of the laboratory shutdown after space on campus was secured and College of Engineering approval secured. Once it arrived in Davis on December 20, 2018, work on the project began in earnest with the initial efforts directed toward developing a new plasma target source. Because of the shutdown of the CTIX facility, the scope of the project thus had to be reduced due to the abbreviated amount of time allocated to the project once the shutdown/move had been completed. Chamber modifications have been completed, including the fabrication and installation of a 38 GHz interferometer, as described in Sec. 3. The thermionic plasma source has been tested and characterized. The magnetic field required for the EBW experiments will be generated by permanent magnets mounted on plates positioned above and below the chamber. Magnetic simulations have been performed, and show that a 3-ring magnet arrangement on each plate, with a plate separation of 50 cm, is required to achieve the ~100 G uniform magnetic field in the interaction region that we feel is necessary to ensure good EBW coupling. We proved unable to successfully revive either of Prof. Luhmann’s two high power (≥20 kW) 94 GHz millimeter-wave sources after their extended time in storage and decided to postpone further efforts and concentrate on slightly lower power sources. Consequently, we were successful in reviving a ~2 kW extended klystron amplifier (EIK), which together with a ~2 kW extended interaction oscillator (EIO) will provide the two pump sources required for the project. Safe operation of the EIO requires extensive modifications to one of Prof. Luhmann’s pulse modulators - these modulator modifications are ongoing, which has unfortunately delayed the planned beat-wave experiments. Details of this work are provided in Sec. 3. Even though project funding has now ended, we still plan to proceed to complete the EIO pulse modulator modifications, install the two ~94 GHz pump wave sources on the target chamber, and conduct unmagnetized tests of the beat-wave concept which involve coupling to unmagnetized electron plasma waves rather than magnetized EBWs. Should these experiments prove successful, we plan to submit a follow-up proposal for additional funding which would allow us to undertake the magnetized EBW experiments.

42 ENGINEERING↗

Beam test evaluation of electromagnetic calorimeter modules made from proton-damaged PbWO 4 crystals

The performance of electromagnetic calorimeter modules made of proton-irradiated PbWO 4 crystals has been studied in beam tests. The modules, similar to those used in the Endcaps of the CMS electromagnetic calorimeter (ECAL), were formed from 5×5 matrices of PbWO 4 crystals, which had previously been exposed to 24 GeV protons up to integrated fluences between 2.1 × 10 13 and 1.3 × 10 14 cm –2 . These correspond to the predicted charged-hadron fluences in the ECAL Endcaps at pseudorapidity η = 2.6 after about 500 fb –1 and 3000 fb –1 respectively, corresponding to the end of the LHC and High Luminosity LHC operation periods. The irradiated crystals have a lower light transmission for wavelengths corresponding to the scintillation light, and a correspondingly reduced light output. A comparison with four crystals irradiated in situ in CMS showed no significant rate dependence of hadron-induced damage. A degradation of the energy resolution and a non-linear response to electron showers are observed in damaged crystals. Direct measurements of the light output from the crystals show the amplitude decreasing and pulse becoming faster as the fluence increases. The latter is interpreted, through comparison with simulation, as a side-effect of the degradation in light transmission. In conclusion, the experimental results obtained can be used to estimate the long term performance of the CMS ECAL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PTT System Performance Evaluation in 3-D Imaging of Calibrated Defects: Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components

Research activity in this project is aimed at developing pulsed thermal tomography (PTT) architecture and algorithms for in-service non-destructive examination (NDE) of additively manufactured (AM) reactor components and materials. Recent advances in AM technology could allow cost-efficient fabrication of parts for operating reactors. However, because of stringent safety requirements, long-term performance of AM reactor components needs to be investigated before AM is widely accepted. Because of the complex shapes and significant surface roughness of components due to layer-by-layer welding process in AM, conventional methods might not be useful for in-service NDE of AM components. PTT is ideally suited for in-service NDE of AM metallic components because the method is non-contact, and offers high resolution #-D imaging of material flaws. The objective of this report is to provide initial evaluate of PTT performance sin detecting calibrated flaws in reactor structural materials. Preliminary COMSOL models were developed to conduct super computing simulations of PTT. In the experimental studies, high strength Stainless Steel 316 and Inconel 718 alloys were considered, as well as lower grade Stainless Steel 304, Nickel 200, and Hastelloy C276. Specimens investigated in this report consisted of approximately 1/4in-thick plates made out of these alloys using conventional manufacturing methods. The calibrated defects were created in the form of flat bottom holes (FBH) drilled in metallic plates. The diameters of FBH's varied from 1mm to 8mm, and their depths below the plate flat surface varied between 1mm and 6mm. The size of the smallest FBH was limited to 1mm because conventional mechanic drills were used for creating the holes. PTT imaging results have shown that 1mm-diameter FBH located 1mm and 2mm below the surface were detectable. Larger size FBH were detectable at greater depth. For example, 6mm-diameter FBH could be detected at 8mm depth. Image contrast varied slightly between the specimens, with the best reconstructions obtained in SS316 and C276 plates. In addition, a 2/3in-thick Inconel 718 nozzle plate produced with additive manufacturing method was imaged with PTT. It was shown that PTT can scan through the plate in approximately 20s. Several modes of 3-D data visualization were explored, including using ImageJ and MATLAB software packages.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Variably Saturated Flow and Multicomponent Biogeochemical Reactive Transport Modeling of a Uranium Bioremediation Field Experiment

Field experiments at a former uranium mill tailings site have identified the potential for stimulating indigenous bacteria to catalyze the conversion of aqueous uranium in the +6 oxidation state to immobile solid-associated uranium in the +4 oxidation state. This effectively removes uranium from solution resulting in groundwater concentrations below actionable standards. Three-dimensional, coupled variably-saturated flow and biogeochemical reactive transport modeling of a 2008 in situ uranium bioremediation field experiment is used to better understand the interplay of transport rates and biogeochemical reaction rates that determine the location and magnitude of key reaction products. A comprehensive reaction network, developed largely through previous 1-D modeling studies, was used to simulate the impacts on uranium behavior of pulsed acetate amendment, seasonal water table variation, spatially-variable physical (hydraulic conductivity, porosity) and geochemical (reactive surface area) material properties. A principal challenge is the mechanistic representation of biologically-mediated terminal electron acceptor process (TEAP) reactions whose products significantly alter geochemical controls on uranium mobility through increases in pH, alkalinity, exchangeable cations, and highly reactive reduction products. In general, these simulations of the 2008 Big Rusty acetate biostimulation field experiment in Rifle, Colorado confirmed previously identified behaviors including (1) initial dominance by iron reducing bacteria that concomitantly reduce aqueous U(VI), (2) sulfate reducing bacteria that become dominant after {approx}30 days and outcompete iron reducers for the acetate electron donor, (3) continuing iron-reducer activity and U(VI) bioreduction during dominantly sulfate reducing conditions, and (4) lower apparent U(VI) removal from groundwater during dominantly sulfate reducing conditions. New knowledge on simultaneously active metal and sulfate reducers has been incorporated into the modeling. In this case, an initially small population of slow growing sulfate reducers is active from the initiation of biostimulation. Three-dimensional, variably saturated flow modeling was used to address impacts of a falling water table during acetate injection. These impacts included a significant reduction in aquifer saturated thickness and isolation of residual reactants and products, as well as unmitigated uranium, in the newly unsaturated vadose zone. High permeability sandy gravel structures resulted in locally high flow rates in the vicinity of injection wells that increased acetate dilution. In downgradient locations, these structures created preferential flow paths for acetate delivery that enhanced local zones of TEAP reactivity and subsidiary reactions. Conversely, smaller transport rates associated with the lower permeability lithofacies (e.g., fine) and vadose zone were shown to limit acetate access and reaction. Once accessed by acetate, however, these same zones limited subsequent acetate dilution and provided longer residence times that resulted in higher concentrations of TEAP products when terminal electron donors and acceptors were not limiting. Finally, facies-based porosity and reactive surface area variations were shown to affect aqueous uranium concentration distributions; however, the ranges were sufficiently small to preserve general trends. Large computer memory and high computational performance were required to simulate the detailed coupled process models for multiple biogeochemical components in highly resolved heterogeneous materials for the 110-day field experiment and 50 days of post-biostimulation behavior. In this case, a highly-scalable subsurface simulator operating on 128 processor cores for 12 hours was used to simulate each realization. An equivalent simulation without parallel processing would have taken 60 days, assuming sufficient memory was available.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary waste management plan of European spallation

The European Spallation Source (ESS) is the European common effort in designing and building a next generation large-scale user facility for studies of the structure and dynamics of materials. The proposed schematic layout of the ESS facility is based on a linear driver (linac) directing the proton beam (5 MW of 2.5 GeV) of 2.8 ms long pulses with a 20 Hz on a tungsten target where neutrons are produced via spallation reactions. Further the neutrons will be moderated to thermal and sub-thermal energies in a couple of moderators placed around the target. The moderators feed 22 beamlines guiding the neutrons to the scattering instruments, mainly for neutron scattering research, as has been previously mentioned. The objective of this work is to develop a waste management plan for ESS facility. In this respect two important aspects are analyzed. First the present status of the problem is outlined as follow. Estimate types and quantities of waste that the ESS project will generate at different stages: commission, operation, decommissioning were derived using: i) precise Monte Carlo calculations ii) scaling the activity from the operation experience of the existing spallation source installations for waste such it is difficult to predict level of activation or for components of the facility in stage of the preconceptual model. Associated waste treatment/conditioning options and final disposal route were further analyzed in order to define the waste type and packet descriptions in agreement with Swedish regulations and policy. It was found that the compilation of completely new waste type descriptions for qualification of the ESS waste for disposal will be necessary. Particular attention was devoted to 'problematic waste' as Beryllium reflector, C-14 from graphite used as core zone of the beam-dump and collimators or waste arising from the purification systems of both Helium and water cooling circuits. Management of waste on ESS site: collection/segregation systems, characterization system, storage options, is also described. In the second step, the acquired information is used for planning and implementing actions involving all participants (ESS, treatment facility operator, disposal operator, regulatory body and other authorized authorities). (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Experimental Study of the 3 He and Neutron Spin Structure at Low Q 2 and The Upgrade of the JLab Polarized 3 He Target

In the scattering process off a nuclear or nucleon target, the Gerasimov-Drell-Hearn (GDH) sum rule for real photons (Q 2 =0 where Q 2 &equiv; -q 2 with q the photon's 4-momentum) relates static properties of the target particle's ground state to dynamic properties of all its excited states. On the other side of the Q 2 spectrum, the Bjorken sum rule holds in the Bjorken limit Q 2 &rarr; &infin;. Bjorken sum rule relates the final structure functions of the proton and neutron to the nucleon axial coupling constant in weak decay. These two sum rules belong to domains where calculations are achievable but use different degrees of freedom: hadronic degrees of freedom at low Q 2 versus partonic degrees of freedom at intermediate Q 2 . Meanwhile, different methods have been used to connect the two sum rules at finite Q 2 values: Chiral Perturbation Theory is used to expand the GDH sum rule while Operator Product Expansion is used to expand the Bjorken sum rule. In recent decades, improvements in polarized beam and polarized target techniques have made it possible to test theoretical predictions in the intermediate Q 2 region. During the Jefferson Lab (JLab) Hall A E97110 experiment, a precise measurement of polarized cross sections was performed at 0.02 < Q 2 < 0.3 GeV 2 using a polarized 3 He target as an effective polarized neutron target. The measured data allowed us to test predictions of Chiral Perturbation Theory at very low Q 2 . Furthermore, an extrapolation to the real photon point Q 2 =0 tests the GDH sum rule on the neutron. In order to reach the small angles necessary for the low Q 2 range, a new septum magnet was installed in Hall A for this experiment. Unfortunately, the magnet was mis-wired during initial running. There were therefore two periods for this experiment: the first period had the defective magnet due to mis-wiring; while in the second period, the magnet had been fixed and was working properly. The cross sections and the asymmetries for the first period must be extracted using a difficult and unusual method employing focal plane variables in the spectrometer. In the work described in this thesis, the target-plane and focal-plane method will be established first and confirmed by elastic scattering cross section measurements from carbon foil and 3 He targets. Cross sections and asymmetries of inelastic scattering were then extracted using the same method, which constitute the main physics results of this thesis. Preliminary results on ITT , the integral of the polarized cross section, were also extracted and are presented in this thesis. In addition to the data analysis of E97110, this thesis includes instrumentation work performed on the polarized 3 He target at JLab. For the 12 GeV program of JLab, the polarized 3 He target is being upgraded to satisfy new experimental requirements. The new target is a convection-based cell with two transfer tubes rather than a single transfer tube as in the former 6 GeV design. The first stage of the target upgrade aims to produce a 40 cm long, 10 amg target that can withstand 30 &mu;A of electron beam current with an in-beam polarization of 55%, doubling the figure-of-merit from the 6 GeV time. Several studies were conducted at the Test Lab of JLab on the new convection cell. Work and improvement done on the Pulse Nuclear Magnetic Resonance (NMR) polarimetry and its test results will be presented. As this thesis is written, the target is being installed in Hall C of JLab in preparation for a 6-month long running from November 2019 to May 2020.

Ton, Nguyen↗

Physical conditions for UO formation in laser-produced uranium plumes

Laser-induced plasma spectroscopy is a powerful method for elemental detection and analysis, however the broadening and merging of densely packed spectral lines can make it especially challenging for studying high-Z elements such as uranium and other actinides. In order to understand the processes occurring in laser-induced plasma, it is necessary to evaluate the variation of its thermodynamic parameters. We performed spatiotemporal diagnostics of uranium species in plasma plumes produced by nanosecond near-infrared laser pulses in low- pressure environment. Spatially- and temporally-resolved emission spectroscopy experiments are supported by modeling of uranium emission and its persistence in the plume. Saha-Eggert equation as well as Boltzmann diagrams generated from numerous U I transitions are used to infer temperature. We report the rst measurements of uranium Stark broadening parameters for U I 499.01 nm and U II 500.82 nm transitions. The Stark widths of selected U transitions were measured by comparing their linewidths with the broadening of O I 777.19 nm line. Electron density was found to be on the order of 1016 cm??3, while the temperature was found to be in the range of 3000{8000 K. In addition to enhancing the fundamental understanding of high-Z plasmas under reduced-pressure environments, the knowledge of Stark broadening parameters could improve modeling capabilities and analytical performance of techniques that rely on emission plasma spectroscopy.

(140.3440) Laser-induced breakdown, (280.4788) Opt↗

Transitions From Stochastic to Point Kinetics Models In Fissile Solutions

Fissile solutions form an integral part of the fuel cycle, being used to store and process both fresh fuel and waste. Fissile solutions are also found within Aqueous Homogeneous Reactors (AHRs) including research reactors such as CRAC and SILENE and also potential future systems which could be used for the production of medical isotopes. In the case of fissile solutions in the fuel cycle, avoiding criticality is a priority but accidents have occurred in which a significant number of fissions occurred. In the case of AHRs, a sustained neutron population and fission rate is desired. In both cases the ability to simulate transients where changes in reactivity cause the neutron population to increase are important. A popular method for the simulation of such transients is the point kinetic method which allows the capture of the major features of a transient at a fraction of the computational runtime and code complexity of more comprehensive modelling technologies. A limitation of the point kinetics method and other mainstream methods of predicting neutron behaviour is that they assume the neutron population is large enough that the mean behaviour will be observed. When the neutron population is low, however, the deviation around the mean behaviour is expected to be relatively large as there is an aleatoric uncertainty arising from the uncertain fate of individual neutrons. Such limitations are of particular importance when the reactivity of a system is rapidly increasing while the neutron population is low, which is often true in accident scenarios involving fissile solutions. This provides the motivation for the coupling of point kinetics and a probabilistic models of fissile solutions. This summary aims to explore some of the behaviours resulting from a low neutron population and rising reactivity using a coupled probabilistic and point kinetics model of a fissile solution. As the effects of a low neutron population are the primary concern of this summary, the point kinetics and thermal hydraulic models used will be relatively simple but these models should be sufficient to capture the most important behaviours of the system in the first minute or so of a transient. This work is an extension of the work found in [1]. In that work the methodology was applied to fast pulses produced by systems such as Godiva and its results were found to compare favourably to experimental and analytical results, such as the burst wait time, in [2]. This work focuses on the application of this methodology to a fissile solution but the method could be applied to a number of criticality safety or reactor operation scenarios through suitable modification of the point kinetics model and would produce a more accurate prediction of the peak power obtained when a system first becomes critical compared to the use of a standard point kinetics model. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dose optimization in pediatric cardiac x-ray imaging

Purpose: The aim of this research was to explore x-ray beam parameters with intent to optimize pediatric x-ray settings in the cardiac catheterization laboratory. This study examined the effects of peak x-ray tube voltage (kVp) and of copper (Cu) x-ray beam filtration independently on the image quality to dose balance for pediatric patient sizes. The impact of antiscatter grid removal on the image quality to dose balance was also investigated. Methods: Image sequences of polymethyl methacrylate phantoms approximating chest sizes typical of pediatric patients were captured using a modern flat-panel receptor based x-ray imaging system. Tin was used to simulate iodine-based contrast medium used in clinical procedures. Measurements of tin detail contrast and flat field image noise provided the contrast to noise ratio. Entrance surface dose (ESD) and effective dose (E) measurements were obtained to calculate the figure of merit (FOM), CNR{sup 2}/dose, which evaluated the dose efficiency of the x-ray parameters investigated. The kVp, tube current (mA), and pulse duration were set manually by overriding the system's automatic dose control mechanisms. Images were captured with 0, 0.1, 0.25, 0.4, and 0.9 mm added Cu filtration, for 50, 55, 60, 65, and 70 kVp with the antiscatter grid in place, and then with it removed. Results: For a given phantom thickness, as the Cu filter thickness was increased, lower kVp was favored. Examining kVp alone, lower values were generally favored, more so for thinner phantoms. Considering ESD, the 8.5 cm phantom had the highest FOM at 50 kVp using 0.4 mm of Cu filtration. The 12 cm phantom had the highest FOM at 55 kVp using 0.9 mm Cu, and the 16 cm phantom had highest FOM at 55 kVp using 0.4 mm Cu. With regard to E, the 8.5 and 12 cm phantoms had the highest FOM at 50 kVp using 0.4 mm of Cu filtration, and the 16 cm phantom had the highest FOM at 50 kVp using 0.25 mm Cu. Antiscatter grid removal improved the FOM for a given set of x-ray conditions. Under aforesaid optimal settings, the 8.5 cm phantom FOM improved by 24% and 33% for ESD and E, respectively. Corresponding improvements were 26% and 24% for the 12 cm phantom and 6% and 15% for the 16 cm phantom. Conclusions: For pediatric patients, using 0.25-0.9 mm Cu filtration in the x-ray beam while maintaining 50-55 kVp, depending on patient size, provided optimal x-ray image quality to dose ratios. These settings, adjusted for x-ray tube loading limits and clinically acceptable image quality, should provide a useful strategy for optimizing iodine contrast agent based cardiac x-ray imaging. Removing the antiscatter grid improved the FOM for the 8.5 and 12 cm phantoms, therefore grid removal is recommended for younger children. Improvement for the 16 cm phantom declined into the estimated margin of error for the FOM; the need for grid removal for older children would depend on practical feasibility in the clinical environment.

60 APPLIED LIFE SCIENCES↗

Burning plasma achieved in inertial fusion

Obtaining a burning plasma is a critical step towards self-sustaining fusion energy. A burning plasma is one in which the fusion reactions themselves are the primary source of heating in the plasma, which is necessary to sustain and propagate the burn, enabling high energy gain. After decades of fusion research, here we achieve a burning-plasma state in the laboratory. These experiments were conducted at the US National Ignition Facility, a laser facility delivering up to 1.9 megajoules of energy in pulses with peak powers up to 500 terawatts. We use the lasers to generate X-rays in a radiation cavity to indirectly drive a fuel-containing capsule via the X-ray ablation pressure, which results in the implosion process compressing and heating the fuel via mechanical work. The burning-plasma state was created using a strategy to increase the spatial scale of the capsule through two different implosion concepts. These experiments show fusion self-heating in excess of the mechanical work injected into the implosions, satisfying several burning-plasma metrics. Additionally, we describe a subset of experiments that appear to have crossed the static self-heating boundary, where fusion heating surpasses the energy losses from radiation and conduction. These results provide an opportunity to study α-particle-dominated plasmas and burning-plasma physics in the laboratory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MAJORANA Collaboration's Experience with Germanium Detectors

A unique way to explore the nature of the neutrino is the search for neutrinoless double beta decay (0νββ). Observation of 0νββ-decay would decisively prove that neutrinos are Majorana particles and that lepton number is violated. The Majorana Demonstrator will perform a search for 0νββ-decay in 76Ge. The experiment is currently under construction at the Sanford Underground Facility (SURF) in South Dakota, USA. The Majorana Demonstrator will use an array of 40 kg of high purity germanium detectors, up to 30 kg of which will be enriched to 86% in 76Ge, surrounded by passive and active shielding. The major goal is to demonstrate a path forward to achieving a background rate at or below 3 counts/(ROI-t-y) in the 4 keV region of interest (ROI) around the 2039 keV Q-value of the 76Ge 0νββ decay. This is required for the next generation of tonne-scale germanium-based 0νββ-decay searches that are designed to probe the neutrino mass scale in the inverted-hierarchy region. Beyond the usage of ultra-clean material and extensive shielding, a key feature to achieve a low background level is a high energy resolution to minimize the ROI and pulse-shape discrimination capability to distinguish signal from background events. These properties are provided by High Purity (HP) P-type Point Contact (PPC) germanium (Ge) detectors. By enriching the natural germanium to 87% in 76Ge the detectors can be used as source and detector simultaneously. At the time of this presentation, 30 enriched detectors with average mass of 840 g have been delivered and successfully tested at SURF. All detectors met the requirements during characterization in vendor cryostat and are now being assembled in the final Majorana Demonstrator experiment.

Mertens, S.↗

Approaching hydro-equivalent ignition in laser direct-drive via target design optimization using novel statistical modeling

Laser direct-drive offers significant advantages in terms of target simplicity, improved energy coupling, and large fuel masses over indirect drive. However, performance degradations from hydrodynamic and laser-plasma instabilities seeded and driven by the direct illumination pose limitations on the parameter space available for achieving ignition. In this paper, new design improvements are identified to forge a path forward for a hydro-equivalent ignition demonstration. The first is related to a new formulation of the statistical model (SM) used to accurately predict target performance directly from input parameters such as laser pulse shape and target specifications. This new SM formulation provides direct guidance on target dimensions and laser beam-to-target radius to achieve the highest fusion yield on the OMEGA laser. The second improvement comes from cooling the deuterium–tritium (DT) ice layer below the triple point right before shot time leading to lower DT vapor densities and higher convergence. Guided by these design improvements, a Bayesian optimization algorithm was used to design an implosion that is predicted to closely approach a Lawson triple product that hydrodynamically scales to ignition if equivalent laser–target coupling is achieved at laser energies typical of the National Ignition Facility.

Deuterium↗

PJM Controller Testing with Prototypic PJM Nozzle Configuration

The U.S. Department of Energy (DOE) Office of River Protection’s Waste Treatment Plant (WTP) is being designed and built to pre-treat and then vitrify a large portion of the wastes in Hanford’s 177 underground waste storage tanks. The WTP consists of three primary facilities—pretreatment, low-activity waste (LAW) vitrification, and high-level waste (HLW) vitrification. The pretreatment facility will receive waste piped from the Hanford tank farms and separate it into a high-volume, low-activity liquid stream stripped of most solids and radionuclides and a much smaller volume of HLW slurry containing most of the solids and most of the radioactivity. Many of the vessels in the pretreatment facility will contain pulse jet mixers (PJM) that will provide some or all of the mixing in the vessels. Pulse jet mixer technology was selected for use in black cell regions of the WTP, where maintenance cannot be performed once hot testing and operations commence. The PJMs have no moving mechanical parts that require maintenance. The vessels with the most concentrated slurries will also be mixed with air spargers and/or steady jets in addition to the mixing provided by the PJMs. Pulse jet mixers are susceptible to overblows that can generate large hydrodynamic forces, forces that can damage mixing vessels or their internal parts. The probability of an overblow increases if a PJM does not fill completely. The purpose of the testing performed for this report was to determine how reliable and repeatable the primary and safety (or backup) PJM control systems are at detecting drive overblows (DOB) and charge vessel full (CVF) conditions. Testing was performed on the ABB 800xA and Triconex control systems. The controllers operated an array of four PJMs installed in an approximately 13 ft diameter × 15 ft tall tank located in the high bay of the Pacific Northwest National Laboratory (PNNL) 336 Building test facility. The PJMs were fitted with 4 inch diameter discharge nozzles representative of the nozzles to be used in the WTP. This work supplemented earlier controller tests done on PJMs with 2 inch nozzles (Bontha et al. 2007). Those earlier tests enabled the selection of appropriate pressure transmitters with associated piping and resulted in an alternate overblow detection algorithm that uses data from pressure transmitters mounted in a water flush line on the PJM airlines. Much of that earlier work was only qualitative, however, due to a data logger equipment failure that occurred during the 2007 testing. The objectives of the current work focused on providing quantitative determinations of the ability of the BNI controllers to detect DOB and CVF conditions. On both control systems, a DOB or CVF is indicated when the values of particular internal functions, called confidence values, cross predetermined thresholds. There are two types of confidence values; one based on a transformation of jet pump pair (JPP) drive and suction pressures, the other based on the pressure in the flush line. In the present testing, we collected confidence levels output from the ABB and Triconex controllers. These data were analyzed in terms of the true and noise confidence peaks generated during multiple cycles of DOB and CVF events. The distributions of peak and noise amplitudes were compared to see if thresholds could be set that would enable the detection of DOB and CVF events at high probabilities, while keeping false detections to low probabilities. Supporting data were also collected on PJM operation, including data on PJM pressures and levels, to provide direct experimental evidence of when PJMs were filling, full, driving, or overblowing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

The Uranium-Containing and Thorium-Containing Anions Studied by Photoelectron Spectroscopy

An in-depth knowledge of actinide chemistry is fundamental to many aspects of nuclear science and technology, including the synthesis and processing of materials and the remediation of waste disposal sites. Among the actinides, the chemical bonding behaviors of actinium and thorium resemble those of the transition metals; the 5f-electrons of protactinium, uranium, neptunium, and plutonium often play important roles in their bonding; and among the still heavier elements, their bonding tends to mimic the lanthanide elements in terms of electron shielding and their f-electron contributions. Bonding that involves 5f-electrons, however, is especially important, in part because of the significance of uranium and plutonium, but also because these elements are among the few where f-electron participation in bonding is relatively common. This work focused on studying uranium-containing and thorium-containing anions in the gas phase using negative ion photoelectron spectroscopy. Since this technique directly probed valence electrons, it was uniquely positioned to address open questions regarding molecular bonding and electron configurations. A particularly important issue concerned how bonding in actinide-containing molecules was affected by modifications to their actinide atoms’ environment, i.e., due to their interaction with ligands. A closely related question was how actinide atoms’ suborbitals were qualitatively reordered and their energies quantitatively shifted as a result of their ligated environments. These were especially relevant issues in regard to uranium due to it having multiple possible oxidation states (OS) and the potential for 5f electron participation in bonding. The effects of ligands on oxidation states and 5f-orbital energies in uranium bonding was expected to be pronounced. Both ligands and excess electrons were seen as probes of actinide atoms within actinide-containing molecules. Our strategy for advancing knowledge of chemical bonding in the actinide-containing species utilized the synergy between experiments and theory, where in some cases experimental results validated theory and where in others computational results assisted in interpreting experiments. Calculations on actinide systems are terrifically challenging due to large spin-orbit interactions, relativistic effects, and just the sheer number of electrons involved. Even in the simplest species, e.g., U and U2, the most sophisticated, modern calculations carried out by the most experienced theorists often only approximate experimentally-measured values, such as electron affinities. For theory to provide confident predictions that can be used to solve real problems it needed an iterative and ultimately corrective mechanism by which its methods can develop further. Experiments can be used to identify when theory has failed; whereupon the subsequent process of using the experiment-theory interplay can be used to find the cause of the failure. Upon fixing it in one case, different test species can be proposed and studied by the experiment-theory combination to determine whether the problem has been corrected. Thus, experiments not only measure the values of molecular properties, they also provide navigational 3 beacons that keep computations off the reefs in an otherwise dark sea with few reference points. Experimental measurements in the actinide field are not only important, they are in actuality essential to computational progress. While it was not always possible to compare the theoreticallydetermined quantity of interest directly with the same experimentally-measured observable, it was usually possible to compare consequential properties that are both calculable and measurable. In the work completed here electron affinities and electronic state spacings were often sensitive consequential parameters. Reasonable agreement between measured and computational values signaled that a calculation that was very likely to be on-track. We had established collaborative relationships with five computational groups, all of which have expertise in computational actinide chemistry. Their PI’s are L. Cheng, D. Dixon, L. Gagliardi, K. Peterson, and B. Vlaisavljevich. Our close interaction with our theory partners led to us suggesting systems to them and them to us. This reciprocal interaction between our experimental and their computational results was among the most important strengths of this work and was a thread woven throughout. Even though anion photoelectron spectroscopic studies are conducted on anions, much of the information that they provide, pertains to the electronic structure of the neutral counterparts of those anions; among these are electron affinities and electronically excited state spacings. Our experimental tools included several specialized ion sources for forming the anionic species of interest, a mass spectrometer for identifying and mass-selecting them, and an anion photoelectron spectrometer for determining their electron affinities (EA) and characterizing the electronic states of the selected anions’ neutral counterparts. Anion photoelectron spectroscopy is conducted by crossing a mass-selected beam of anions with a fixed-frequency laser beam and energy-analyzing the resultant photodetached electrons. The photodetachment process is governed by the energyconserving relationship: hν = EBE + EKE, where hν is the photon’s energy, EBE is the electron binding (photodetachment transition) energy, and EKE is the electron’s kinetic energy. In our apparatus mass-selection is accomplished via time-of-flight mass spectrometry (TOF-MS), electron energy analysis is achieved with either a magnetic bottle or by velocity mapped imaging. Photodetachment of electrons from anions is implemented via either Nd:YAG or excimer lasers. The photodetachment transition energy, i.e., the EBE, between the ground vibrational and electronic state of an anion and the ground vibrational and electronic state of that anion’s neutral counterpart is the adiabatic electron affinity (EA) of that neutral molecule. Likewise, photodetachment transitions between the ground vibrational and electronic state of an anion and the various electronically-excited states of that anion’s corresponding neutral map the electronic spectrum of that neutral species, i.e., the spectral spacings in the photoelectron spectrum are a mirror image of the neutral’s electronic spectrum. It was, of course, crucial to be able to form the anionic species of interest. There, we had a particularly broad field of anion sources from which to choose. These included several variants of pulsed laser vaporization (LV), laser photoemission, infrared desorption plus photoemission, pulsed arc discharge (PACIS), electrospray ionization (ESI), and Rydberg electron transfer (RET). Each of these anion sources were readily combined with, i.e., connected to, the anion photoelectron spectroscopic portion of our apparatus as described above. Among the sources that utilize lasers, visible light for LV sources as well as IR for desorption sources are provided by Nd:YAG lasers. Ultraviolet photons are provided by both Nd:YAG and excimer lasers, whereas the excitation wavelengths for RET experiments come from two Nd:YAG-pumped dye lasers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling light signals using data from the first pulsed neutron source program at the DUNE vertical drift ColdBox test facility at the CERN Neutrino Platform

In this paper, we present a first quantitative test of detected light signals produced in a pulsed neutron source run in a small vertical drift LArTPC at the CERN Neutrino Platform ColdBox test facility. The ColdBox cryostat, detectors, neutron sources, and particle interactions are modeled and simulated using Fluka. We demonstrate the ability to identify the contribution from neutron interactions using X-ARAPUCA photodetectors, and show first comparisons of data to simulation, which indicate reasonable agreement. A time constant is also fitted from the neutron-beam-off light signal spectrum and found consistent between data and simulation. Several important systematic effects are discussed and serve as guides for future runs at larger LArTPCs.

Detector modelling and simulations I (interaction ↗

Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon

Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, 39Ar, a ß emitter of cosmogenic origin. For large detectors, the atmospheric 39Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of 39Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of 39Ar with respect to AAr by a factor larger than 1400. Assessing the 39Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly ?-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.

Noble liquid detectors, Dark Matter detectors, Cry↗