Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Modeling and Analysis of Hybrid Pixel Detector Deficiencies for Scientific Applications

Semiconductor hybrid pixel detectors often consist of a pixellated sensor layer bump bonded to a matching pixelated readout integrated circuit (ROIC). The sensor can range from high resistivity Si to III-V materials, whereas a Si CMOS process is typically used to manufacture the ROIC. Independent, device physics and electronic design automation (EDA) tools are used to determine sensor characteristics and verify functional performance of ROICs respectively with significantly different solvers. Some physics solvers provide the capability of transferring data to the EDA tool. However, single pixel transient simulations are either not feasible due to convergence difficulties or are prohibitively long. A simplified sensor model, which includes a current pulse in parallel with detector equivalent capacitor, is often used; even then, spice type top-level (entire array) simulations range from days to weeks. In order to analyze detector deficiencies for a particular scientific application, accurately defined transient behavioral models of all the functional blocks are required. Furthermore, various simulations, such as transient, noise, Monte Carlo, inter-pixel effects, etc. of the entire array need to be performed within a reasonable time frame without trading off accuracy. The sensor and the analog front-end can be modeling using a real number modeling language, as complex mathematical functions or detailed data can be saved to text files, for further top-level digital simulations. Parasitically aware digital timing is extracted in a standard delay format (sdf) from the pixel digital back-end layout as well as the periphery of the ROIC. For any given input, detector level worst-case and best-case simulations are performed using a Verilog simulation environment to determine the output. Each top-level transient simulation takes no more than 10-15 minutes. The impact of changing key parameters such as sensor Poissonian shot noise, analog front-end bandwidth, jitter due to clock distribution etc. can be accurately analyzed to determine ROIC architectural viability and bottlenecks. Hence the impact of the detector parameters on the scientific application can be studied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulse-by-pulse transient thermal deformation in crystal optics under high-repetition-rate FEL

Time-domain modeling of the thermal deformation of crystal optics can help define acceptable operational ranges across the pulse-energy repetition-rate phase space. In this paper, we have studied the transient thermal deformation of a water-cooled diamond crystal for a cavity-based X-ray free-electron laser (CBXFEL), either an X-ray free-electron laser oscillator (XFELO) or a regenerative amplifier X-ray free-electron laser (RAFEL), by numerical simulations including finite-element analysis and advanced data processing. Pulse-by-pulse transient thermal deformation of a 50 µm-thick diamond crystal has been performed with X-ray pulse repetition rates between 50 kHz and 1 MHz. Results for temperature and thermal deformation have been compared with the results of transient analysis using a continuous wave (CW) power loading. Temperature and thermal deformation results from pulse-by-pulse transient analysis vary with time about the results for the CW case for the same average power. The variation amplitude increases with pulse energy and decreases with repetition rate. When the repetition rate increases to infinity, both temperature and thermal deformation converge to the results for the CW case. Two critical time scales for the operation of crystal optics in a CBXFEL are (1) first-turn time, i.e. the time for the XFEL pulse to complete the first turn around the cavity so that the crystal sees the recirculated XFEL pulse, and (2) period-end time, i.e. the time that the next electron bunch arrives for the amplification, so that the crystal outcouples the amplified FEL power. For the same average power, simulation results show that the crystal thermal deformation seen by the XFEL beam decreases with repetition rate at the first-turn time of a 300 m-long cavity and increases with repetition rate at the period-end time. For the wavefront preservation requirement of the crystal optics, a pulse-energy versus repetition-rate phase space has been established. The upper bounds of the pulse energy at both first-turn and period-end times decreases with repetition rate, especially at the period-end time. The upper bound of the thermal deformation of the crystal at the period-end time for any repetition frequency can be estimated from the CW case. For a water-cooled diamond crystal of dimension 5 mm × 5 mm × 0.05 mm, the time to reach a quasi steady-state is about 50 ms for temperature and 50 µs for thermal deformation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Inhibition of B-NHEJ in Plateau-Phase Cells Is Not a Direct Consequence of Suppressed Growth Factor Signaling

Purpose: It has long been known that the proliferation status of a cell is a determinant of radiation response, and the available evidence implicates repair of DNA double-strand breaks (DSBs) in the underlying mechanism. Recent results have shown that a novel, highly error-prone pathway of nonhomologous end joining (NHEJ) operating as backup (B-NHEJ) processes DSBs in irradiated cells when the canonical, DNA-PK (DNA-dependent protein kinase)-dependent pathway of NHEJ (D-NHEJ) is compromised. Notably, B-NHEJ shows marked reduction in efficiency when D-NHEJ-deficient cells cease to grow and enter a plateau phase. This phenomenon is widespread and observed in cells of different species with defects in core components of D-NHEJ, with the notable exception of DNA-PKcs (DNA-dependent protein kinase, catalytic subunit). Using new, standardized serum-deprivation protocols, we re-examine the growth requirements of B-NHEJ and test the role of epidermal growth factor receptor (EGFR) signaling in its regulation. Methods and Materials: DSB repair was measured by pulsed-field gel electrophoresis in cells maintained under different conditions of growth. Results: Serum deprivation in D-NHEJ-deficient cells causes a rapid reduction in B-NHEJ similar to that measured in normally growing cells that enter the plateau phase of growth. Upon serum deprivation, reduction in B-NHEJ activity is evident at 4 h and reaches a plateau reflecting maximum inhibition at 12-16 h. The inhibition is reversible, and B-NHEJ quickly recovers to the levels of actively growing cells upon supply of serum to serum-deprived cells. Chemical inhibition of EGFR in proliferating cells inhibits only marginally B-NHEJ and addition of EGFR in serum-deprived cells increases only a marginally B-NHEJ. Conclusions: The results document a rapid and fully reversible adaptation of B-NHEJ to growth activity and point to factors beyond EGFR in its regulation. They show notable differences in the regulation of error-prone DSB repair pathways between proliferating and non proliferating cells that may present new treatment design opportunities in radiation therapy.

60 APPLIED LIFE SCIENCES↗

A cascaded model of spectral distortions due to spectral response effects and pulse pileup effects in a photon-counting x-ray detector for CT

Purpose: Energy discriminating, photon-counting detectors (PCDs) are an emerging technology for computed tomography (CT) with various potential benefits for clinical CT. The photon energies measured by PCDs can be distorted due to the interactions of a photon with the detector and the interaction of multiple coincident photons. These effects result in distorted recorded x-ray spectra which may lead to artifacts in reconstructed CT images and inaccuracies in tissue identification. Model-based compensation techniques have the potential to account for the distortion effects. This approach requires only a small number of parameters and is applicable to a wide range of spectra and count rates, but it needs an accurate model of the spectral distortions occurring in PCDs. The purpose of this study was to develop a model of those spectral distortions and to evaluate the model using a PCD (model DXMCT-1; DxRay, Inc., Northridge, CA) and various x-ray spectra in a wide range of count rates. Methods: The authors hypothesize that the complex phenomena of spectral distortions can be modeled by: (1) separating them into count-rate independent factors that we call the spectral response effects (SRE), and count-rate dependent factors that we call the pulse pileup effects (PPE), (2) developing separate models for SRE and PPE, and (3) cascading the SRE and PPE models into a combined SRE+PPE model that describes PCD distortions at both low and high count rates. The SRE model describes the probability distribution of the recorded spectrum, with a photo peak and a continuum tail, given the incident photon energy. Model parameters were obtained from calibration measurements with three radioisotopes and then interpolated linearly for other energies. The PPE model used was developed in the authors’ previous work [K. Taguchi et al., “Modeling the performance of a photon counting x-ray detector for CT: Energy response and pulse pileup effects,” Med. Phys. 38(2), 1089–1102 (2011)]. The agreement between the x-ray spectra calculated by the cascaded SRE+PPE model and the measured spectra was evaluated for various levels of deadtime loss ratios (DLR) and incident spectral shapes, realized using different attenuators, in terms of the weighted coefficient of variation (COV{sub W}), i.e., the root mean square difference weighted by the statistical errors of the data and divided by the mean. Results: At low count rates, when DLR < 10%, the distorted spectra measured by the DXMCT-1 were in agreement with those calculated by SRE only, with COV{sub W}'s less than 4%. At higher count rates, the measured spectra were also in agreement with the ones calculated by the cascaded SRE+PPE model; with PMMA as attenuator, COV{sub W} was 5.6% at a DLR of 22% and as small as 6.7% for a DLR as high as 55%. Conclusions: The x-ray spectra calculated by the proposed model agreed with the measured spectra over a wide range of count rates and spectral shapes. The SRE model predicted the distorted, recorded spectra with low count rates over various types and thicknesses of attenuators. The study also validated the hypothesis that the complex spectral distortions in a PCD can be adequately modeled by cascading the count-rate independent SRE and the count-rate dependent PPE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance of a segmented 6 Li-loaded liquid scintillator detector for the PROSPECT experiment

This study describes the design and performance of a 50 liter, two-segment 6 Li-loaded liquid scintillator detector that was designed and operated as prototype for the PROSPECT (Precision Reactor Oscillation and Spectrum) Experiment. The two-segment detector was constructed according to the design specifications of the experiment. It features low-mass optical separators, an integrated source and optical calibration system, and materials that are compatible with the 6 Li-doped scintillator developed by PROSPECT. We demonstrate a high light collection of 850±20 PE/MeV, an energy resolution of σ = 4.0±0.2% at 1 MeV, and efficient pulse-shape discrimination of low dE/dx (electronic recoil) and high dE/dx (nuclear recoil) energy depositions. An effective scintillation attenuation length of 85±3 cm is measured in each segment. The 0.1% by mass concentration of 6 Li in the scintillator results in a measured neutron capture time of τ = 42.8±0.2 μs. The long-term stability of the scintillator is also discussed. Finally, the detector response meets the criteria necessary for achieving the PROSPECT physics goals and demonstrates features that may find application in fast neutron detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution 3D-printed plastic scintillators with tertiary dye

Additive manufacturing offers efficient production of plastic scintillators with nontrivial geometries using vat polymerization, allowing fabrication of geometries which would be difficult or even impossible to produce using conventional subtractive manufacturing. This work presents a novel photocurable scintillator formula that includes coumarin 450 as a tertiary dye to enable high-resolution 3D printing via the manipulation of the 405 nm cure light. Bulk photocured and 3D printed (with and without tertiary dye) samples were compared through observational assessment and spectral response. All samples showed pulse shape discrimination between neutron and gamma events. Inclusion of the tertiary dye has minimal impact on emission spectrum and light output, but significant impact on print resolution as shown by comparison of printed high-complexity geometries and feature resolution test objects. With the use of a cure-limiting dye, unsupported features — such as freestanding pillars — were resolvable down to 0.7 mm. Even finer resolution at or below 0.1 mm was achieved in fully supported, integrated structures printed with off-the-shelf 405 nm desktop 3D printer. Scintillators demonstrated a light output up to 50% of EJ-200 with a PSD figure of merit up to 1.35 at 0.9–1.1 MeVee.

36 MATERIALS SCIENCE↗

Three Dimensional Simulations of Multiphase Flows Using a Lattice Boltzmann Method Suitable for High Density Ratios - 12126

Multiphase flows involving gas and liquid phases can be observed in engineering operations at various Department of Energy sites, such as mixing of slurries using pulsed-air mixers and hydrogen gas generation in liquid waste tanks etc. The dynamics of the gas phase in the liquid domain play an important role in the mixing effectiveness of the pulsed-air mixers or in the level of gas pressure build-up in waste tanks. To understand such effects, computational fluid dynamics methods (CFD) can be utilized by developing a three-dimensional computerized multiphase flow model that can predict accurately the behavior of gas motion inside liquid-filled tanks by solving the governing mathematical equations that represent the physics of the phenomena. In this paper, such a CFD method, lattice Boltzmann method (LBM), is presented that can model multiphase flows accurately and efficiently. LBM is favored over traditional Navier-Stokes based computational models since interfacial forces are handled more effectively in LBM. The LBM is easier to program, more efficient to solve on parallel computers, and has the ability to capture the interface between different fluid phases intrinsically. The LBM used in this paper can solve for the incompressible and viscous flow field in three dimensions, while at the same time, solve the Cahn-Hillard equation to track the position of the gas-liquid interface specifically when the density and viscosity ratios between the two fluids are high. This feature is of primary importance since the previous LBM models proposed for multiphase flows become unstable when the density ratio is larger than 10. The ability to provide stable and accurate simulations at large density ratios becomes important when the simulation case involves fluids such as air and water with a density ratio around 1000 that are common to many engineering problems. In order to demonstrate the capability of the 3D LBM method at high density ratios, a static bubble simulation is conducted to solve for the pressure difference between the inside and outside of a gas bubble in a liquid domain. Once the results show that the method is in agreement with the Laplace law, buoyant bubble simulations are conducted. The initial results obtained for bubble shape during the rising process was found to be in agreement with the theoretical expectations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiation-Induced Effects on the Extraction Properties of Hexa-n-octylnitrilo-triacetamide (HONTA) Complexes of Americium and Europium

The candidate An(III)/Ln(III) separation ligand hexa-n-octylnitrilo-triacetamide (HONTA) was irradiated under envisioned SELECT (Solvent Extraction from Liquid waste using Extractants of CHON-type for Transmutation) process conditions (n-dodecane/0.1 M HNO 3 ) using a solvent test loop in conjunction with cobalt-60 gamma irradiation. The extent of HONTA radiolysis and complimentary degradation product formation was quantified by HPLC-ESI-MS/MS. Further, the impact of HONTA radiolysis on process performance was evaluated by measuring the change in 243 Am and 154 Eu distribution ratios as a function of absorbed gamma dose. HONTA was found to decay exponentially with increasing dose, affording a dose coefficient of d = (4.48 ± 0.19) × 10 –3 kGy –1 . Multiple degradation products were detected by HPLC-ESI-MS/MS with dioctylamine being the dominant quantifiable species. Both 243 Am and 154 Eu distribution ratios exhibited an induction period of ~70 kGy for extraction (0.1 M HNO 3 ) and back-extraction (4.0 M HNO 3 ) conditions, after which both values decreased with absorbed dose. The decrease in distribution ratios was attributed to a combination of the destruction of HONTA and ingrowth of dioctylamine, which is capable of interfering in metal ion complexation. Furthermore, the loss of HONTA with absorbed gamma dose was predominantly attributed to its reaction with the n-dodecane radical cation (R˙ + ). These R˙ + reaction kinetics were measured for HONTA and its 241 Am and 154 Eu complexes using picosecond pulsed electron radiolysis techniques. All three second-order rate coefficients (k) were essentially diffusion limited in n-dodecane indicating a significant reaction pathway: k(HONTA + R˙ + ) = (7.6 ± 0.8) × 10 9 M –1 s –1 , k(Am(HONTA) 2 + R˙ + ) = (7.1 ± 0.7) × 10 10 M –1 s –1 , and k(Eu(HONTA) 2 + R˙ + ) = (9.5 ± 0.5) × 10 10 M –1 s –1 . HONTA-metal ion complexation afforded an order-of-magnitude increase in rate coefficient. Additional nanosecond time-resolved measurements showed that both direct and indirect HONTA radiolysis yielded the short-lived (< 100 ns) HONTA radical cation and a second long-lived (µs) species identified as the HONTA triplet excited state. The latter was confirmed by a series of oxygen quenching picosecond pulsed electron measurements, affording a quenching rate coefficient of k( 3 [HONTA]* + O 2 ) = 2.2 × 10 8 M –1 s –1 . Overall, both the HONTA radical cation and triplet excited state are important precursors to the suite of measured HONTA degradation products.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Assessment and characterization of the total geometric uncertainty in Gamma Knife radiosurgery using polymer gels

Purpose: This work proposes and implements an experimental methodology, based on polymer gels, for assessing the total geometric uncertainty and characterizing its contributors in Gamma Knife (GK) radiosurgery. Methods: A treatment plan consisting of 26, 4-mm GK single shot dose distributions, covering an extended region of the Leksell stereotactic space, was prepared and delivered to a polymer gel filled polymethyl methacrylate (PMMA) head phantom (16 cm diameter) used to accurately reproduce every link in the GK treatment chain. The center of each shot served as a 'control point' in the assessment of the GK total geometric uncertainty, which depends on (a) the spatial dose delivery uncertainty of the PERFEXION GK unit used in this work, (b) the spatial distortions inherent in MR images commonly used for target delineation, and (c) the geometric uncertainty contributor associated with the image registration procedure performed by the Leksell GammaPlan (LGP) treatment planning system (TPS), in the case that registration is directly based on the apparent fiducial locations depicted in each MR image by the N-shaped rods on the Leksell localization box. The irradiated phantom was MR imaged at 1.5 T employing a T2-weighted pulse sequence. Four image series were acquired by alternating the frequency encoding axis and reversing the read gradient polarity, thus allowing the characterization of the MR-related spatial distortions. Results: MR spatial distortions stemming from main field (B{sub 0}) inhomogeneity as well as from susceptibility and chemical shift phenomena (also known as sequence dependent distortions) were found to be of the order of 0.5 mm, while those owing to gradient nonlinearities (also known as sequence independent distortions) were found to increase with distance from the MR scanner isocenter extending up to 0.47 mm at an Euclidean distance of 69.6 mm. Regarding the LGP image registration procedure, the corresponding average contribution to the total geometric uncertainty ranged from 0.34 to 0.80 mm. The average total geometric uncertainty, which also includes the GK spatial dose delivery uncertainty, was found equal to (0.88 {+-} 0.16), (0.88 {+-} 0.26), (1.02 {+-} 0.09), and (1.15 {+-} 0.24) mm for the MR image series acquired with the read gradient polarity (direction) set toward right, left, posterior, and anterior, respectively. Conclusions: The implemented methodology seems capable of assessing the total geometric uncertainty, as well as of characterizing its contributors, ascribed to the entire GK treatment delivery (i.e., from MR imaging to GK dose delivery) for an extended region of the Leksell stereotactic space. Results obtained indicate that the selection of both the frequency encoding axis and the read gradient polarity during MRI acquisition may affect the magnitude as well as the spatial components of the total geometric uncertainty.

60 APPLIED LIFE SCIENCES↗

System Performance Testing of the Pulse-Echo Ultrasonic Instrument for Critical Velocity Determination during Hanford Tank Waste Transfer Operations - 13584

The delivery of Hanford double-shell tank waste to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) is governed by specific Waste Acceptance Criteria that are identified in ICD 19 - Interface Control Document for Waste Feed. Waste must be certified as acceptable before it can be delivered to the WTP. The fluid transfer velocity at which solid particulate deposition occurs in waste slurry transport piping (critical velocity) is a key waste acceptance parameter that must be accurately characterized to determine if the waste is acceptable for transfer to the WTP. Washington River Protection Solutions and the Pacific Northwest National Laboratory have been evaluating the ultrasonic PulseEcho instrument since 2010 for its ability to detect particle settling and determine critical velocity in a horizontal slurry transport pipeline for slurries containing particles with a mean particle diameter of =14 micrometers (μm). In 2012 the PulseEcho instrument was further evaluated under WRPS' System Performance test campaign to identify critical velocities for slurries that are expected to be encountered during Hanford tank waste retrieval operations or bounding for tank waste feed. This three-year evaluation has demonstrated the ability of the ultrasonic PulseEcho instrument to detect the onset of critical velocity for a broad range of physical and rheological slurry properties that are likely encountered during the waste feed transfer operations between the Hanford tank farms and the WTP. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

G4CMP: Condensed matter physics simulation using the G$\scriptsize{\mathrm{EANT}}$4 toolkit

G4CMP simulates phonon and charge transport in cryogenic semiconductor crystals using the Geant4 toolkit. The transport code is capable of simulating the propagation of acoustic phonons as well as electron and hole charge carriers. Herein processes for anisotropic phonon propagation, oblique charge-carrier propagation, and phonon emission by accelerated charge carriers are included. The simulation reproduces theoretical predictions and experimental observations such as phonon caustics, heat-pulse propagation times, and mean charge-carrier drift velocities. In addition to presenting the physics and features supported by G4CMP, this report outlines example applications from the dark matter and quantum information science communities. These communities are applying G4CMP to model and design devices for which the energy transported by phonons and charge carriers is germane to the performance of superconducting instruments and circuits placed on silicon and germanium substrates. The G4CMP package is available to download from GitHub: github.com/kelseymh/G4CMP.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of Metal Ion Complexation on the Radiolytic Longevity of Butyramide Extractants under Direct Dissolution Process Conditions

The direct dissolution of voloxidized used nuclear fuel (UNF) into an organic solution–comprised of diluent and specialized extractants–poses a promising alternative to the traditional liquid–liquid solvent extraction approach to reprocessing UNF. However, moving to direct dissolution removes the presence of a concentrated nitric acid aqueous phase, which has been shown to significantly influence the radiolytic longevity of extractants in conventional extraction flowsheets. Given the limited knowledge of radiation effects under direct dissolution conditions, here we present a time-resolved and dose-accumulation study on the impact of direct dissolution conditions on the radiolytic longevity of two candidate butyramide extractants, N,N-di(2-ethylhexyl) butyramide (DEHBA) and N,N-di(2-ethylhexyl)isobutyramide (DEHiBA), in pre-equilibrated n-dodecane solvent in the presence and absence of process-relevant metal ions, specifically, uranium and rhenium. Loss G(DEHBA) and G(DEHiBA) values were found to be comparable to each other, with an average of 0.37 ± 0.02 μmol J –1 , and to previous data from the γ irradiation of DEHBA and DEHiBA under conventional solvent extraction conditions. Rhenium, and by extension technetium, extraction had a modest decrease (~10%) in the overall radiolytic stability of DEHiBA only, despite >2× observed increases in chemical kinetic reactivity of the corresponding complexes with the n-dodecane radical cation. Uranium loading, on the other hand, significantly improved the lifetime of both ligands (>30%) under γ irradiation, with a greater stabilization observed for DEHBA over DEHiBA. The observed radioprotective effect afforded by uranium loading is fortuitous for the longevity of direct dissolution solvent.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Effect of chemical environment on the radiation chemistry of N , N -di-(2-ethylhexyl)butyramide (DEHBA) and plutonium retention

N,N-di-(2-ethylhexyl)butyramide (DEHBA) has been proposed as part of a hydro-reprocessing solvent extraction system for the co-extraction of uranium and plutonium from spent nuclear fuel, owing to its selectivity for hexavalent uranium and tetravalent plutonium. However, there is a critical lack of quantitative understanding regarding the impact of chemical environment on the radiation chemistry of DEHBA, and how this would affect process performance. Here we present a systematic investigation into the radiolytic degradation of DEHBA in a range of n-dodecane solvent system formulations, where we subject DEHBA to gamma irradiation, measure reaction kinetics, ligand integrity, degradation product formation, and investigate solvent system performance through uranium and plutonium extraction and strip distribution ratios. The rate of DEHBA degradation in n-dodecane was found to be slow (G = -0.31 ± 0.02 μmol J -1 ) but enhanced upon contact with the oxidizing conditions of the investigated solvent systems (organic-only, or in contact with either 0.1 or 3.0 M aqueous nitric acid). Two major degradation products were identified in the organic phase, bis-2-ethylhexylamine (b2EHA) and N-(2-ethylhexyl)butyramide (MEHBA), resulting from the cleavage of C–N bonds, and could account for the total loss of DEHBA up to ~300 kGy for organic-only conditions. Both b2EHA and MEHBA were also found to be susceptible to radiolytic degradation, having G-values of -0.12 ± 0.01 and -0.08 ± 0.01 μmol J -1 , respectively. Solvent extraction studies showed: (i) negligible change in uranium extraction and stripping with increasing absorbed dose; and (ii) plutonium extraction and retention exhibits complex dependencies on absorbed dose and chemical environment. Organic-only conditions afforded enhanced plutonium extraction and retention attributed to b2EHA, while acid contacts inhibited this effect and promoted significant plutonium retention for the highest acidity. Overall it has been demonstrated that chemical environment during irradiation has a significant influence on the extent of DEHBA degradation and plutonium retention.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Environmental Characterization Scans Using Sodium-Iodide Gamma Spectroscopy to Determine Ra-226 Concentration in Surface Soil - 16326

The recent natural gas drilling boom has brought heightened attention to the issue of TENORM waste management. Radioactive residues from the extraction, treatment, and purification of materials containing uranium and thorium, or their progeny, pose a public health hazard primarily in the form of ground water contamination. Hydraulic fracturing can liberate formation waters from shale; the high salinity of which can cause radium to move with the water to the surface. The disposal and handling of this water has been a subject of public controversy. For soil remediation projects, radium-226 is generally one of the radionuclides of concern due to its alpha emissions. However performing a survey scan for Ra-226 is difficult because its photon emissions are low energy and have minimal probability of emission per decay (186.2 keV, 3.3% abundance). Additionally resolving its emission from U-235 (185.7 keV, 57% abundance) with field instrumentation is not feasible. Therefore detection of Ra-226 relies on the presence and photon emissions of its progeny. This paper outlines methodology for calculating the minimum detectable concentration of Ra-226 in characterization scans using a sodium-iodide detector array coupled with a multi-channel analyzer. Using progeny ingrowth as a detection proxy requires knowing decay time in order to determine progeny emission rates. Knowledge of site history, process, and prior survey results can be key in determining an accurate decay time. However in the absence of such information in-situ measurements can be used to estimate decay time by comparing observed progeny emission ratios against established values. These values are determined using Oak Ridge National Laboratory's ORIGEN-ARP program to generate photon energy spectra for Ra-226 and its progeny at specified time intervals. Once decay time is established, the detector's minimum detectable concentration can be calculated by synthesizing the expected emission spectra and Los Alamos National Laboratory's Monte Carlo N-Particle transport code to simulate detector response. Traditionally, one of the steps in calculating a system's minimum detectable concentration is to place an appropriate button source under the detector, record the response, and then move the source by a specified increment. This process is repeated until the detector's spatial efficiency has been mapped. Due to the impracticality of performing this with Ra-226 button sources of varying decay times, Monte Carlo N-Particle transport code was utilized to determine the detector's spatial efficiency. A dime sized source with the established emission spectra was placed into the center of a rectangle of soil. This rectangle, including the source, was used as a lattice element to fill the region of space below the detector. The simulation was designed to track the energy distribution of pulses created in the sodium iodide crystal using the F8 tally, and was setup to isolate each source; thereby correlating detector response to source position. The simulation output required post-processing to determine conversion factors from counts per second to disintegrations per second. Post-processing accounted for subtraction of the Compton continuum, and average the data over the scanning pattern to obtain the expected spatial sensitivity during a characterization study. This was performed for the following photo-peaks: 609 keV (Bi-214), and 1764 keV (Bi-214). For calculation of the scan minimum detectable concentration, the surveyor efficiency coefficient from NUREG 1507 was supplanted in favor of a scan speed deviation factor. This was used because the detector utilizes computerized data collection (spatial and spectral). This report finds that, for two shielded 10.16 cm x 10.16 cm x 40.64 cm sodium-iodide crystals with integrated multi-channel analyzers, the minimum detectable concentration in surface soils is less than 1 pCi per gram Ra-226 for a 1 second survey measurement. These results assume a volumetric source with a maximum depth of 15.24 cm and a minimum decay time of 21 days. Verification of the system's capabilities was performed by sending soil samples from scanned areas, and locations where in-situ measurements were performed, to an independent laboratory for analysis. The laboratory results demonstrated that scanned area was principally comprised of soil containing less than 1 pCi per gram Ra-226. This borders the system MDC and it underestimated the concentration of radium in the soil. The probable causes of this is escape of radon gas from the surface soil. Radon is the daughter of radium, and has a high mobility in soil. If the gas escapes, then the progeny used as the detection proxy will be present in lower than expected concentrations. Radionuclide identification using high volume sodium-iodide crystals in low level characterization scans is demonstrated to be possible. Further system refinement will focus on developing a methodology to estimate a radon escape factor for site specific use. Accounting for radon escape in the top 15.24 cm of soil will allow the system to better estimate Ra-226 concentrations in soil. This is a significant advancement over the gross counting statistics used in most studies to satisfy MARSSIM survey requirements, because it will increase stakeholder confidence. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High-precision {sup 28}Si(p,t){sup 26}Si reaction to determine {sup 22}Mg({alpha},p){sup 25}Al reaction rates

The rise time of stellar x-ray bursts is a signature of thermonuclear runaway processes in the atmosphere of neutron stars and is highly sensitive to a series of ({alpha},p) reactions via high-lying resonances in sd-shell nuclei. Lacking data for the relevant resonance levels, the stellar reaction rates have been calculated using statistical, Hauser-Feshbach models, assuming a high-level density. This assumption may not be correct in view of the selectivity of the ({alpha},p) reaction to natural parity states. We measured the {sup 28}Si(p,t){sup 26}Si reaction with a high-resolution spectrometer to identify resonance levels in {sup 26}Si above the {alpha}-emission threshold at 9.164 MeV excitation energy. These resonance levels are used to calculate the stellar reaction rate of the {sup 22}Mg({alpha},p){sup 25}Al reaction and to test the validity of the statistical assumption.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Active Measurement of Plasma Parameters in Over-Dense MFE Reactor Plasma Using High Frequency Beat-Wave Resonantly Generated Thermal Bernstein Waves

UC Davis was funded to explore the combination of beat-wave excitation and laser scattering to make completely non-invasive determination of local plasma conditions. This involves the use of two high frequency mm-wave sources of differing frequencies (the pump waves) to excite plasma waves at the difference of the frequencies, which is known as the beat frequency. The difference frequency or the frequency of the beat wave is chosen so that we produce plasma waves whose fluctuating electron density is a sensitive function of plasma parameters at the location where the source waves overlap. This fluctuation can be detected from outside the plasma, by measuring the deflection of a probe beam directed at the overlap region between the two pump waves (i.e., collective scattering). This work is an extension of mm-wave frequencies of a 10 GHz beat-wave experiment conducted on the DDT toroidal device (see Fig. 1) in a magnetized plasma where the excited Langmuir wave is replaced by the magnetized upper hybrid wave. Here, two high power (> 1 kW) ~94 GHz pump sources will be employed to match the upper hybrid resonance. The primary envisioned experiment is to drive the electron Bernstein wave (EBW) in the interior of a magnetized plasma. The EBW is a hot-plasma electrostatic wave, which cannot propagate in vacuum. Roots of the EBW dispersion relation occur at frequencies slightly higher than harmonics of the electron cyclotron frequency. Use of the EBW has particular advantages for measuring plasma magnetic field in plasmas with relatively high density and low magnetic field, as is the case in spherical tokamaks. This is the “over dense” condition of future efficient high beta magnetic confinement fusion reactors such as the spherical tokamak (STs). The overarching goal of the proposed project is to demonstrate beat wave EBW excitation in low density and temperature parameters that are directly scalable to over-dense spherical tokamaks such as NSTX or MAST, where measurement of magnetic field by electron cyclotron emission (ECE) is experimentally complex, and requires models of plasma profiles in order to interpret results. In such experiments, availability of point measurements of magnetic field strength provided by a beat-wave diagnostic would serve as a powerful independent check on the ECE results, serving to validate the assumed profiles and wave-propagation models used. The first step was to assemble/modify the target chamber in which the beat-wave plasma experiments will take place. Here, the target chamber of the CTIX compact-toroid (spheromak) injector was chosen. At the time that the proposal was submitted, the aim was to conduct the experiments in the CTIX experimental facilities located at the Livermore campus of UC Davis using microwave/mm-wave equipment brought from the main campus., However, by the time DoE funds for this project were awarded, the CTIX experimental facilities located at the Livermore campus of UC Davis were in the process of being shut down due to the closure of the Livermore campus by Lawrence Livermore National Laboratory (LLNL). Consequently, the equipment needed for this project was crated up and shipped from Livermore to Davis as part of the laboratory shutdown after space on campus was secured and College of Engineering approval secured. Once it arrived in Davis on December 20, 2018, work on the project began in earnest with the initial efforts directed toward developing a new plasma target source. Because of the shutdown of the CTIX facility, the scope of the project thus had to be reduced due to the abbreviated amount of time allocated to the project once the shutdown/move had been completed. Chamber modifications have been completed, including the fabrication and installation of a 38 GHz interferometer, as described in Sec. 3. The thermionic plasma source has been tested and characterized. The magnetic field required for the EBW experiments will be generated by permanent magnets mounted on plates positioned above and below the chamber. Magnetic simulations have been performed, and show that a 3-ring magnet arrangement on each plate, with a plate separation of 50 cm, is required to achieve the ~100 G uniform magnetic field in the interaction region that we feel is necessary to ensure good EBW coupling. We proved unable to successfully revive either of Prof. Luhmann’s two high power (≥20 kW) 94 GHz millimeter-wave sources after their extended time in storage and decided to postpone further efforts and concentrate on slightly lower power sources. Consequently, we were successful in reviving a ~2 kW extended klystron amplifier (EIK), which together with a ~2 kW extended interaction oscillator (EIO) will provide the two pump sources required for the project. Safe operation of the EIO requires extensive modifications to one of Prof. Luhmann’s pulse modulators - these modulator modifications are ongoing, which has unfortunately delayed the planned beat-wave experiments. Details of this work are provided in Sec. 3. Even though project funding has now ended, we still plan to proceed to complete the EIO pulse modulator modifications, install the two ~94 GHz pump wave sources on the target chamber, and conduct unmagnetized tests of the beat-wave concept which involve coupling to unmagnetized electron plasma waves rather than magnetized EBWs. Should these experiments prove successful, we plan to submit a follow-up proposal for additional funding which would allow us to undertake the magnetized EBW experiments.

42 ENGINEERING↗

Beam test evaluation of electromagnetic calorimeter modules made from proton-damaged PbWO 4 crystals

The performance of electromagnetic calorimeter modules made of proton-irradiated PbWO 4 crystals has been studied in beam tests. The modules, similar to those used in the Endcaps of the CMS electromagnetic calorimeter (ECAL), were formed from 5×5 matrices of PbWO 4 crystals, which had previously been exposed to 24 GeV protons up to integrated fluences between 2.1 × 10 13 and 1.3 × 10 14 cm –2 . These correspond to the predicted charged-hadron fluences in the ECAL Endcaps at pseudorapidity η = 2.6 after about 500 fb –1 and 3000 fb –1 respectively, corresponding to the end of the LHC and High Luminosity LHC operation periods. The irradiated crystals have a lower light transmission for wavelengths corresponding to the scintillation light, and a correspondingly reduced light output. A comparison with four crystals irradiated in situ in CMS showed no significant rate dependence of hadron-induced damage. A degradation of the energy resolution and a non-linear response to electron showers are observed in damaged crystals. Direct measurements of the light output from the crystals show the amplitude decreasing and pulse becoming faster as the fluence increases. The latter is interpreted, through comparison with simulation, as a side-effect of the degradation in light transmission. In conclusion, the experimental results obtained can be used to estimate the long term performance of the CMS ECAL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PTT System Performance Evaluation in 3-D Imaging of Calibrated Defects: Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components

Research activity in this project is aimed at developing pulsed thermal tomography (PTT) architecture and algorithms for in-service non-destructive examination (NDE) of additively manufactured (AM) reactor components and materials. Recent advances in AM technology could allow cost-efficient fabrication of parts for operating reactors. However, because of stringent safety requirements, long-term performance of AM reactor components needs to be investigated before AM is widely accepted. Because of the complex shapes and significant surface roughness of components due to layer-by-layer welding process in AM, conventional methods might not be useful for in-service NDE of AM components. PTT is ideally suited for in-service NDE of AM metallic components because the method is non-contact, and offers high resolution #-D imaging of material flaws. The objective of this report is to provide initial evaluate of PTT performance sin detecting calibrated flaws in reactor structural materials. Preliminary COMSOL models were developed to conduct super computing simulations of PTT. In the experimental studies, high strength Stainless Steel 316 and Inconel 718 alloys were considered, as well as lower grade Stainless Steel 304, Nickel 200, and Hastelloy C276. Specimens investigated in this report consisted of approximately 1/4in-thick plates made out of these alloys using conventional manufacturing methods. The calibrated defects were created in the form of flat bottom holes (FBH) drilled in metallic plates. The diameters of FBH's varied from 1mm to 8mm, and their depths below the plate flat surface varied between 1mm and 6mm. The size of the smallest FBH was limited to 1mm because conventional mechanic drills were used for creating the holes. PTT imaging results have shown that 1mm-diameter FBH located 1mm and 2mm below the surface were detectable. Larger size FBH were detectable at greater depth. For example, 6mm-diameter FBH could be detected at 8mm depth. Image contrast varied slightly between the specimens, with the best reconstructions obtained in SS316 and C276 plates. In addition, a 2/3in-thick Inconel 718 nozzle plate produced with additive manufacturing method was imaged with PTT. It was shown that PTT can scan through the plate in approximately 20s. Several modes of 3-D data visualization were explored, including using ImageJ and MATLAB software packages.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗