Search NASA⌕ Search

SEARCH · Search NASA

Results for “parameter selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Design and construction of a compact, high-repetition-rate ultrafast electron diffraction instrument

We present the design and performance of a compact ultrafast electron diffraction instrument. The diffractometer provides a means of examining time-resolved ultrafast dynamical properties of solids. The system’s utilization is discussed in terms of instrument parameters and diffraction data from selected condensed matter samples. Here, the difractometer’s performance is highlighted in terms of detection sensitivity, instrumental temporal resolution, and the electron beam transverse coherence length. Following specific details of the construction, we present a practical discussion of parameters such as repetition rate and provide advice on general construction approaches for laboratory-based, keV ultrafast electron diffractometers. In addition, design guidance for constructing a compact electron gun source that is well-suited for studying diffraction from hard condensed matter is given. A unique data acquisition scheme, utilizing high laser repetition rates, is presented.

47 OTHER INSTRUMENTATION↗

A Kriging-Based Approach to Autonomous Experimentation with Applications to X-Ray Scattering

Abstract Modern scientific instruments are acquiring data at ever-increasing rates, leading to an exponential increase in the size of data sets. Taking full advantage of these acquisition rates will require corresponding advancements in the speed and efficiency of data analytics and experimental control. A significant step forward would come from automatic decision-making methods that enable scientific instruments to autonomously explore scientific problems—that is, to intelligently explore parameter spaces without human intervention, selecting high-value measurements to perform based on the continually growing experimental data set. Here, we develop such an autonomous decision-making algorithm that is physics-agnostic, generalizable, and operates in an abstract multi-dimensional parameter space. Our approach relies on constructing a surrogate model that fits and interpolates the available experimental data, and is continuously refined as more data is gathered. The distribution and correlation of the data is used to generate a corresponding uncertainty across the surrogate model. By suggesting follow-up measurements in regions of greatest uncertainty, the algorithm maximally increases knowledge with each added measurement. This procedure is applied repeatedly, with the algorithm iteratively reducing model error and thus efficiently sampling the parameter space with each new measurement that it requests. We validate the method using synthetic data, demonstrating that it converges to faithful replica of test functions more rapidly than competing methods, and demonstrate the viability of the approach in an experimental context by using it to direct autonomous small-angle (SAXS) and grazing-incidence small-angle (GISAXS) x-ray scattering experiments.

36 MATERIALS SCIENCE↗

flowVS: channel-specific variance stabilization in flow cytometry

Abstract Background Comparing phenotypes of heterogeneous cell populations from multiple biological conditions is at the heart of scientific discovery based on flow cytometry (FC). When the biological signal is measured by the average expression of a biomarker, standard statistical methods require that variance be approximately stabilized in populations to be compared. Since the mean and variance of a cell population are often correlated in fluorescence-based FC measurements, a preprocessing step is needed to stabilize the within-population variances. Results We present a variance-stabilization algorithm, called flowVS, that removes the mean-variance correlations from cell populations identified in each fluorescence channel. flowVS transforms each channel from all samples of a data set by the inverse hyperbolic sine (asinh) transformation. For each channel, the parameters of the transformation are optimally selected by Bartlett’s likelihood-ratio test so that the populations attain homogeneous variances. The optimum parameters are then used to transform the corresponding channels in every sample. flowVS is therefore an explicit variance-stabilization method that stabilizes within-population variances in each channel by evaluating the homoskedasticity of clusters with a likelihood-ratio test. With two publicly available datasets, we show that flowVS removes the mean-variance dependence from raw FC data and makes the within-population variance relatively homogeneous. We demonstrate that alternative transformation techniques such as flowTrans, flowScape, logicle, and FCSTrans might not stabilize variance. Besides flow cytometry, flowVS can also be applied to stabilize variance in microarray data. With a publicly available data set we demonstrate that flowVS performs as well as the VSN software, a state-of-the-art approach developed for microarrays. Conclusions The homogeneity of variance in cell populations across FC samples is desirable when extracting features uniformly and comparing cell populations with different levels of marker expressions. The newly developed flowVS algorithm solves the variance-stabilization problem in FC and microarrays by optimally transforming data with the help of Bartlett’s likelihood-ratio test. On two publicly available FC datasets, flowVS stabilizes within-population variances more evenly than the available transformation and normalization techniques. flowVS-based variance stabilization can help in performing comparison and alignment of phenotypically identical cell populations across different samples. flowVS and the datasets used in this paper are publicly available in Bioconductor.

60 APPLIED LIFE SCIENCES↗

Design considerations for the free-electron laser with the self-seeding and current-enhanced SASE

Cost of the facility producing x-rays using free-electron lasers (FELs) is largely defined by the electron beam energy E 0 and by the availability of the undulators with a certain period that will support production of photons in the range of photon energies between ℏω 1 and ℏω 2 corresponding to the wavelengths λ 1 and λ 2 . Here we first consider a trade-off of various parameters that could provide initial guidance in the cost optimization of the FEL covering the range of photon energies from ℏω 1 = 4 keV to ℏω 2 = 5 keV. In this analysis we also compare helical and planar undulators. After selecting a preferred set of parameters, we proceed with a preliminary design of the FEL that employs self-seeding and enhanced SASE techniques.

Zholents, Alexander↗

Efficient sensitivity analysis of the thermal profile in powder bed fusion of metals using hypercomplex automatic differentiation finite element method

Rapid cyclic temperature fluctuation occurring in powder bed fusion of metals using a laser beam (PBF-LB/M) influences the formation of flaws in printed parts. Consequently, there is a pressing need to enhance the quality of printed parts by developing innovative methodologies that can predict thermal histories and help uncover the intricate relationships between process parameters and thermal profiles. Sensitivity Analysis (SA) emerges as an essential tool for this, offering the potential for process optimization and enhanced quality control. Nonetheless, conventional SA methodologies often incur in excessive computational costs and potential numerical approximation errors. Here, to address this technical challenge, we present a novel method for SA that integrates the HYPercomplex-based Automatic Differentiation (HYPAD) technique with transient thermal simulations conducted via the finite element method (FEM). Leveraging this methodology, we efficiently and accurately perform SA for PBF-LB/M processes in a post-processing step. Compared to traditional methods like Finite Differences (FD), HYPAD-FEM required 96 % less computational time for obtaining sensitivities for 22 process parameters, under a comparative study conducted within the context of the 2018–02 AM benchmark of the National Institute of Standards and Technology. In summary, HYPAD-FEM offers superior efficiency and accuracy in SA over conventional methods, delivering the best sensitivity of a model without the need for step-size selection and problem or parameter-based implementations.

36 MATERIALS SCIENCE↗

Sensitivity of Austempering Heat Treatment of Ductile Irons to Changes in Process Parameters

Austempered ductile iron (ADI) is frequently obtained by means of a three-step austempering heat treatment. The parameters of this process play a crucial role on the microstructure of the final product. This paper considers the influence of some process parameters (i.e., the initial microstructure of ductile iron and the thermal cycle) on key features of the heat treatment (such as minimum required time for austenitization and austempering and microstructure of the final product). A computational simulation of the austempering heat treatment is reported in this work, which accounts for a coupled thermo-metallurgical behavior in terms of the evolution of temperature at the scale of the part being investigated (the macroscale) and the evolution of phases at the scale of microconstituents (the microscale). The paper focuses on the sensitivity of the process by looking at a sensitivity index and scatter plots. The sensitivity indices are determined by using a technique based on the variance of the output. The results of this study indicate that both the initial microstructure and the thermal cycle parameters play a key role in the production of ADI. This work also provides a guideline to help selecting values of the appropriate process parameters to obtain parts with a required microstructural characteristic.

36 MATERIALS SCIENCE↗

Mathematical model parameters for describing the particle size spectra of knife-milled corn stover

Particle size distributions of Corn stover (Zea mays L.) created by a knife mill were determined using integral classifying screens with sizes from 12.7 to 50.8 mm, operating at speeds from 250 to 500 rpm, and mass input rates ranging from 1 to 9 kg min_1. Particle distributions were classified using American Society of Agricultural and Biological Engineers (ASABE) standardised sieves for forage analysis that incorporated a horizontal sieving motion. The sieves were made from machined-aluminium with their thickness proportional to the sieve opening dimensions. A wide range of analytical descriptors that could be used to mathematically represent the range of particle sizes in the distributions were examined. The correlation coefficients between geometric mean length and screen size, feed rate, and speed were 0.980, 0.612, and _0.027, respectively. Screen size and feed rate directly influenced particle size, whereas operating speed had a weak indirect relation with particle size. The Rosin Rammler equation fitted the chopped corn stover size distribution data with coefficient of determination (R2) > 0.978. This indicated that particle size distribution of corn stover was well-fit by the Rosin Rammler function. This can be attributed to the fact that Rosin Rammler expression was well suited to the skewed distribution of particle sizes. Skewed distributions occurred when significant quantities of particles, either finer or coarser, existed or were removed from region of the predominant size. The mass relative span was slightly greater than 1, which indicated that it was a borderline narrow to wide distribution of particle sizes. The uniformity coefficient was <4.0 for 19.0 50.8 mm screens, which indicated particles of relatively uniform size. Knife mill chopping of corn stover produced fine-skewed mesokurtic particles with 12.7 50.8 mm screens. Size-related parameters, namely, geometric mean length, Rosin Rammler size parameter, median length, effective length, and size guide number, were well predicted at R2 values of 0.981, 0.982, 0.979, 0.950 and 0.978, respectively as a function of knife mill screen size, feed rate, and speed. Results of this analysis of particle sizes could be applied to the selection of knife mill operating parameters to produce a particular size of corn stover chop, and could serve as a guide for the relationships among various analytic descriptors of biomass particle distributions.

09 BIOMASS FUELS↗

Morphometric Atlas Selection for Automatic Brachial Plexus Segmentation

Purpose: The purpose of this study was to determine the effects of atlas selection based on different morphometric parameters, on the accuracy of automatic brachial plexus (BP) segmentation for radiation therapy planning. The segmentation accuracy was measured by comparing all of the generated automatic segmentations with anatomically validated gold standard atlases developed using cadavers. Methods and Materials: Twelve cadaver computed tomography (CT) atlases (3 males, 9 females; mean age: 73 years) were included in the study. One atlas was selected to serve as a patient, and the other 11 atlases were registered separately onto this “patient” using deformable image registration. This procedure was repeated for every atlas as a patient. Next, the Dice and Jaccard similarity indices and inclusion index were calculated for every registered BP with the original gold standard BP. In parallel, differences in several morphometric parameters that may influence the BP segmentation accuracy were measured for the different atlases. Specific brachial plexus-related CT-visible bony points were used to define the morphometric parameters. Subsequently, correlations between the similarity indices and morphometric parameters were calculated. Results: A clear negative correlation between difference in protraction-retraction distance and the similarity indices was observed (mean Pearson correlation coefficient = −0.546). All of the other investigated Pearson correlation coefficients were weak. Conclusions: Differences in the shoulder protraction-retraction position between the atlas and the patient during planning CT influence the BP autosegmentation accuracy. A greater difference in the protraction-retraction distance between the atlas and the patient reduces the accuracy of the BP automatic segmentation result.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Vadose Zone Flow and Transport Parameters Data Package for the Hanford Site Composite Analysis and Cumulative Impact Evaluation

This report provides a description of the basis for the development and implementation of a conceptual model for vadose zone flow and transport for the composite analysis (CA) groundwater pathway analysis and the cumulative impact evaluation (CIE). The parameterization for a numerical model is intimately linked to the conceptual model framework. The report describes the basis for the selection of hydraulic and transport parameters for the hydrostratigraphic units (HSUs) identified in the 200 East and 200 West Areas. Whenever data are sparse or unavailable, surrogate hydraulic properties are chosen based on samples collected within the 200 Areas and nearby locations that are representative of sediments characteristic of the HSUs identified elsewhere.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A review of thermo-hydro-mechanical modeling of coupled processes in fractured rock: From continuum to discontinuum perspective

Coupled thermo-hydro-mechanical (THM) processes in fractured rock are playing a crucial role in geoscience and geoengineering applications. Diverse and conceptually distinct approaches have emerged over the past decades in both continuum and discontinuum perspectives leading to significant progress in their comprehending and modeling. This review paper offers an integrated perspective on existing modeling methodologies providing guidance for model selection based on the initial and boundary conditions. By comparing various models, one can better assess the uncertainties in predictions, particularly those related to the conceptual models. The review explores how these methodologies have significantly enhanced the fundamental understanding of how fractures respond to fluid injection and production, and improved predictive capabilities pertaining to coupled processes within fractured systems. It emphasizes the importance of utilizing advanced computational technologies and thoroughly considering fundamental theories and principles established through past experimental evidence and practical experience. The selection and calibration of model parameters should be based on typical ranges and applied to the specific conditions of applications. The challenges arising from inherent heterogeneity and uncertainties, nonlinear THM coupled processes, scale dependence, and computational limitations in representing field scale fractures are discussed. Realizing potential advances on computational capacity calls for methodical conceptualization, mathematical modeling, selection of numerical solution strategies, implementation, and calibration to foster simulation outcomes that intricately reflect the nuanced complexities of geological phenomena. Future research efforts should focus on innovative approaches to tackle the hurdles and advance the state-of-the-art in this critical field of study.

Coupling scheme↗

Compiled properties of nucleonic matter and nuclear and neutron star models from nonrelativistic and relativistic interactions

Here, this paper compiles the model parameters and zero-temperature properties of an extensive collection of published theoretical nuclear interactions, including 255 nonrelativistic (Skyrme-like) forces, 270 relativistic mean field (RMF) and point-coupling (RMF-PC) forces, and 13 Gogny-like forces. This forms the most exhaustive tabulation of model parameters to date. The properties of uniform symmetric matter and pure neutron matter at the saturation density are determined. Symmetry properties found from the second-order term of a Taylor expansion in neutron excess are compared with the energy difference of pure neutron and symmetric nuclear matter at the saturation density. Selected liquid-droplet model parameters, including the surface tension and surface symmetry energy, are determined for semi-infinite surfaces. Theoretical liquid droplet model neutron skin thicknesses of the neutron-rich closed-shell nuclei 48 Ca and 208 Pb are compared with published theoretical Hartree-Fock and experimental results. A similar comparison is made between theoretical liquid-droplet and experimental values of dipole polarizabilities. In addition, radii, binding energies, moments of inertia and tidal deformabilities of 1.2⁢M ⊙ , 1.4⁢M ⊙ and 1.6⁢M ⊙ neutron stars are computed. An extensive correlation analysis of bulk matter, nuclear structure, and low-mass neutron star properties is performed and compared with nuclear experiments and astrophysical observations.

nuclear astrophysics↗

Converging Shock Flows for a Mie-Grüneisen Equation of State

Previous work has shown that the one-dimensional (1D) inviscid compressible flow (Euler) equations admit a wide variety of scale-invariant solutions (including the famous Noh, Sedov, and Guderley shock solutions) when the included equation of state (EOS) closure model assumes a certain scale-invariant form. However, this scale-invariant EOS class does not include even simple models used for shock compression of crystalline solids, including many broadly applicable representations of Mie-Grüneisen EOS. Intuitively, this incompatibility naturally arises from the presence of multiple dimensional scales in the Mie-Grüneisen EOS, which are otherwise absent from scale-invariant models that feature only dimensionless parameters (such as the adiabatic index in the ideal gas EOS). The current work extends previous efforts intended to rectify this inconsistency, by using a scale-invariant EOS model to approximate a Mie-Grüneisen EOS form. To this end, the adiabatic bulk modulus for the Mie-Grüneisen EOS is constructed, and its key features are used to motivate the selection of a scale-invariant approximation form. Here, the remaining surrogate model parameters are selected through enforcement of the Rankine-Hugoniot jump conditions for an infinitely strong shock in a Mie-Grüneisen material. Finally, the approximate EOS is used in conjunction with the 1D inviscid Euler equations to calculate a semi-analytical Guderley-like imploding shock solution in a metal sphere and to determine if and when the solution may be valid for the underlying Mie-Grüneisen EOS.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Automating Risk Assessments of Hazardous Material Shipments for Transportation Routes and Mode Selection

The METEOR project at Idaho National Laboratory (INL) successfully addresses the difficult problem in risk assessment analyses of combining the results from bounding deterministic simulation results with probabilistic (Monte Carlo) risk assessment techniques. This paper describes a software suite designed to perform sensitivity and cost/benefit analyses on selected transportation routes and vehicles to minimize risk associated with the shipment of hazardous materials. METEOR uses Monte Carlo techniques to estimate the probability of an accidental release of a hazardous substance along a proposed transportation route. A METEOR user selects the mode of transportation, origin and destination points, and charts the route using interactive graphics. Inputs to METEOR (many selections built in) include crash rates for the specific aircraft, soil/rock type and population densities over the proposed route, and bounding limits for potential accident types (velocity, temperature, etc.). New vehicle, materials, and location data are added when available. If the risk estimates are unacceptable, the risks associated with alternate transportation modes or routes can be quickly evaluated and compared. Systematic optimizing methods will provide the user with the route and vehicle selection identified with the lowest risk of hazardous material release. The effects of a selected range of potential accidents such as vehicle impact, fire, fuel explosions, excessive containment pressure, flooding, etc. are evaluated primarily using hydrocodes capable of accurately simulating the material response of critical containment components. Bounding conditions that represent credible accidents (i.e; for an impact event, velocity, orientations, and soil conditions) are used as input parameters to the hydrocode models yielding correlation functions relating accident parameters to component damage. The Monte Carlo algorithms use random number generators to make selections at the various decision points such as; crash, location, etc. For each pass through the routines, when a crash is randomly selected, crash parameters are then used to determine if failure has occurred using either external look up tables, correlations functions from deterministic calculations, or built in data libraries. The effectiveness of the software was recently demonstrated in safety analyses of the transportation of radioisotope systems for the US Dept. of Energy. These methods are readily adaptable to estimating risks associated with a variety of hazardous shipments such as spent nuclear fuel, explosives, and chemicals.

42 ENGINEERING↗

MASS CALIBRATION AND COSMOLOGICAL ANALYSIS OF THE SPT-SZ GALAXY CLUSTER SAMPLE USING VELOCITY DISPERSION σ {sub v} AND X-RAY Y {sub X} MEASUREMENTS

We present a velocity-dispersion-based mass calibration of the South Pole Telescope Sunyaev-Zel'dovich effect survey (SPT-SZ) galaxy cluster sample. Using a homogeneously selected sample of 100 cluster candidates from 720 deg{sup 2} of the survey along with 63 velocity dispersion (σ {sub v}) and 16 X-ray Y {sub X} measurements of sample clusters, we simultaneously calibrate the mass-observable relation and constrain cosmological parameters. Our method accounts for cluster selection, cosmological sensitivity, and uncertainties in the mass calibrators. The calibrations using σ {sub v} and Y {sub X} are consistent at the 0.6σ level, with the σ {sub v} calibration preferring ∼16% higher masses. We use the full SPT{sub CL} data set (SZ clusters+σ {sub v}+Y {sub X}) to measure σ{sub 8}(Ω{sub m}/0.27){sup 0.3} = 0.809 ± 0.036 within a flat ΛCDM model. The SPT cluster abundance is lower than preferred by either the WMAP9 or Planck+WMAP9 polarization (WP) data, but assuming that the sum of the neutrino masses is ∑m {sub ν} = 0.06 eV, we find the data sets to be consistent at the 1.0σ level for WMAP9 and 1.5σ for Planck+WP. Allowing for larger ∑m {sub ν} further reconciles the results. When we combine the SPT{sub CL} and Planck+WP data sets with information from baryon acoustic oscillations and Type Ia supernovae, the preferred cluster masses are 1.9σ higher than the Y {sub X} calibration and 0.8σ higher than the σ {sub v} calibration. Given the scale of these shifts (∼44% and ∼23% in mass, respectively), we execute a goodness-of-fit test; it reveals no tension, indicating that the best-fit model provides an adequate description of the data. Using the multi-probe data set, we measure Ω{sub m} = 0.299 ± 0.009 and σ{sub 8} = 0.829 ± 0.011. Within a νCDM model we find ∑m {sub ν} = 0.148 ± 0.081 eV. We present a consistency test of the cosmic growth rate using SPT clusters. Allowing both the growth index γ and the dark energy equation-of-state parameter w to vary, we find γ = 0.73 ± 0.28 and w = –1.007 ± 0.065, demonstrating that the expansion and the growth histories are consistent with a ΛCDM universe (γ = 0.55; w = –1)

79 ASTRONOMY AND ASTROPHYSICS↗

Multivariate Normal Tissue Complication Probability Modeling of Heart Valve Dysfunction in Hodgkin Lymphoma Survivors

Purpose: To establish a multivariate normal tissue complication probability (NTCP) model for radiation-induced asymptomatic heart valvular defects (RVD). Methods and Materials: Fifty-six patients treated with sequential chemoradiation therapy for Hodgkin lymphoma (HL) were retrospectively reviewed for RVD events. Clinical information along with whole heart, cardiac chambers, and lung dose distribution parameters was collected, and the correlations to RVD were analyzed by means of Spearman's rank correlation coefficient (Rs). For the selection of the model order and parameters for NTCP modeling, a multivariate logistic regression method using resampling techniques (bootstrapping) was applied. Model performance was evaluated using the area under the receiver operating characteristic curve (AUC). Results: When we analyzed the whole heart, a 3-variable NTCP model including the maximum dose, whole heart volume, and lung volume was shown to be the optimal predictive model for RVD (Rs = 0.573, P<.001, AUC = 0.83). When we analyzed the cardiac chambers individually, for the left atrium and for the left ventricle, an NTCP model based on 3 variables including the percentage volume exceeding 30 Gy (V30), cardiac chamber volume, and lung volume was selected as the most predictive model (Rs = 0.539, P<.001, AUC = 0.83; and Rs = 0.557, P<.001, AUC = 0.82, respectively). The NTCP values increase as heart maximum dose or cardiac chambers V30 increase. They also increase with larger volumes of the heart or cardiac chambers and decrease when lung volume is larger. Conclusions: We propose logistic NTCP models for RVD considering not only heart irradiation dose but also the combined effects of lung and heart volumes. Our study establishes the statistical evidence of the indirect effect of lung size on radio-induced heart toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Singling out modified gravity parameters and data sets reveals a dichotomy between Planck and lensing

ABSTRACT An important route to testing general relativity (GR) at cosmological scales is usually done by constraining modified gravity (MG) parameters added to the Einstein perturbed equations. Most studies have analysed so far constraints on pairs of MG parameters, but here, we explore constraints on one parameter at a time while fixing the other at its GR value. This allows us to analyse various models while benefiting from a stronger constraining power from the data. We also explore which specific data sets are in tension with GR. We find that models with (μ = 1, η) and (μ, η = 1) exhibit a 3.9σ and 3.8σ departure from GR when using Planck18 + Supernovae type Ia (SNe) + Baryon acoustic oscillation (BAO), while (μ, η) shows a tension of 3.4σ. We find no tension with GR for models with the MG parameter Σ fixed to its GR value. Using a Bayesian model selection analysis, we find that some one-parameter MG models are moderately favoured over ΛCDM when using all data set combinations except Planck cosmic microwave background lensing and dark energy survey data. Namely, Planck18 shows a moderate tension with GR that only increases when adding any combination of redshift space distortion, SNe, or BAO. However, adding lensing diminishes or removes these tensions, which can be attributed to the ability of lensing in constraining the MG parameter Σ. The two overall groups of data sets are found to have a dichotomy when performing consistency tests with GR, which may be due to systematic effects, lack of constraining power, or modelling. These findings warrant further investigation using more precise data from ongoing and future surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulation-based Performance Evaluation of Model Predictive Control for Building Energy Systems

The performance of model predictive control (MPC) can be significantly affected by different choices of controller parameters such as the time intervals for model discretization and control sampling. Due to the lack of a systematic understanding on how these parameters affect control performance, they are usually selected arbitrarily in practice.In this paper, the combined impacts of selected time intervals for model discretization and control sampling on the performance of MPC are comprehensively investigated for the first time through detailed simulations. Specifically, a typical MPC strategy is first designed to improve building operations based on a reduced-order model of building dynamics. Then, the performance of the designed MPC is evaluated against different choices of time intervals for model discretization and control sampling on a simulated office building. The detailed simulation results reveal that the time interval for model discretization has a much greater influence on the performance of MPC than the time interval for control sampling. Although the time interval for control sampling usually receives more attentions in practice, it turns out that the time interval for model discretization affects the prediction performance, cost saving, and computation time simultaneously and more significantly. Therefore, the simulation-based performance evaluation presented here sheds light on the impacts of different time intervals and facilitates their selection for practical applications of MPC to building operations

Huang, Sen↗

Real Time Flame Monitoring of Gasifier and Injectors

This project is a multistage effort with the final goal to develop a practical and reliable nonintrusive gasifier injector monitor to assess burner wear and need for replacement. The project team included the National Energy Technology Laboratory (NETL), Gas Technology Institute (GTI), North Carolina State University, and ConocoPhillips. This report presents the results of the sensor development and testing initially at GTI combustion laboratory with natural gas flames, then at the Canada Energy Technology Center (CANMET), Canada in the atmospheric coal combustor as well as in the pilot scale pressurized entrained flow gasifier, and finally the sensor capabilities were demonstrated at the Pratt and Whitney Rocketdyne (PWR) Gasifier and the Wabash River Repowering plant located in West Terre Haute, IN. The initial tests demonstrated that GTI gasifier sensor technology was capable of detecting shape and rich/lean properties of natural gas air/oxygen enriched air flames. The following testing at the Vertical Combustor Research Facility (VCRF) was a logical transition step from the atmospheric natural gas flames to pressurized coal gasification environment. The results of testing with atmospheric coal flames showed that light emitted by excited OH* and CH* radicals in coal/air flames can be detected and quantified. The maximum emission intensities of OH*, CH*, and black body (char combustion) occur at different axial positions along the flame length. Therefore, the excitation rates of CH* and OH* are distinct at different stages of coal combustion and can be utilized to identify and characterize processes which occur during coal combustion such as devolatilization, char heating and burning. To accomplish the goals set for Tasks 4 and 5, GTI utilized the CANMET Pressurized Entrained Flow Gasifier (PEFG). The testing parameters of the PEFG were selected to simulate optimum gasifier operation as well as gasifier conditions normally resulting from improper operation or failed gasifier injectors. The sensor developed under previous tasks was used to assess the spectroscopic characteristics of the gasifier flame. The obtained spectral data were successfully translated into flame temperature measurements. It was also demonstrated that the reduced spectral data could be very well correlated with very important gasification process parameters such as the air/fuel and water/fuel ratio. Any of these parameters (temperature, air/fuel, and water/fuel) is sufficient to assess burner wear; however, the tested sensor was capable of monitoring all three of them plus the flame shape as functions of burner wear. This will likely be a very powerful tool which should enable significant improvements in gasifier efficiency, reliability, and availability. The sensor technology was presented to the project's industrial partner (ConocoPhillips). The partner expressed its strong interest in continuing to participate in the field validation phase of GTI's Flame Monitor Project. Finally the sensor was tested in the PWR (Pratt & Whitney Rocketdyne) gasification plant located at GTI's research campus and at the ConocoPhillips industrial scale gasifier at Wabash River Indiana. The field trials of the GTI Gasifier sensor modified to withstand high temperature and pressure corrosive atmosphere of the industrial entrain flow gasifier. The project team successfully demonstrated the Gasifier Sensor system ability to monitor gasifier interior temperature maintaining unobstructed optical access for in excess of six week without any maintenance. The sensor examination upon completion of the trial revealed that the system did not sustain any damage and required minor cleanup of the optics.

01 COAL, LIGNITE, AND PEAT↗