A Method to Recognize Anatomical Site and Image Acquisition View in X-ray Images

A method was developed to recognize anatomical site and image acquisition view automatically in 2D X-ray images that are used in image-guided radiation therapy. The purpose is to enable site and view dependent automation and optimization in the image processing tasks including 2D-2D image registration, 2D image contrast enhancement, and independent treatment site confirmation. The X-ray images for 180 patients of six disease sites (the brain, head-neck, breast, lung, abdomen, and pelvis) were included in this study with 30 patients each site and two images of orthogonal views each patient. A hierarchical multiclass recognition model was developed to recognize general site first and then specific site. Each node of the hierarchical model recognized the images using a feature extraction step based on principal component analysis followed by a binary classification step based on support vector machine. Given two images in known orthogonal views, the site recognition model achieved a 99% average F1 score across the six sites. If the views were unknown in the images, the average F1 score was 97%. If only one image was taken either with or without view information, the average F1 score was 94%. The accuracy of the site-specific view recognition models was 100%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An improved method for simulating microcalcifications in digital mammograms

The assessment of the performance of a digital mammography system requires an observer study with a relatively large number of cases with known truth which is often difficult to assemble. Several investigators have developed methods for generating hybrid abnormal images containing simulated microcalcifications. This article addresses some of the limitations of earlier methods. The new method is based on digital images of needle biopsy specimens. Since the specimens are imaged separately from the breast, the microcalcification attenuation profile scan is deduced without the effects of over and underlying tissues. The resulting templates are normalized for image acquisition specific parameters and reprocessed to simulate microcalcifications appropriate to other imaging systems, with different x-ray, detector and image processing parameters than the original acquisition system. This capability is not shared by previous simulation methods that have relied on extracting microcalcifications from breast images. The method was validated by five experienced mammographers who compared 59 pairs of simulated and real microcalcifications in a two-alternative forced choice task designed to test if they could distinguish the real from the simulated lesions. They also classified the shapes of the microcalcifications according to a standardized clinical lexicon. The observed probability of correct choice was 0.415, 95% confidence interval (0.284, 0.546), showing that the radiologists were unable to distinguish the lesions. The shape classification revealed substantial agreement with the truth (mean kappa=0.70), showing that we were able to accurately simulate the lesion morphology. While currently limited to single microcalcifications, the method is extensible to more complex clusters of microcalcifications and to three-dimensional images. It can be used to objectively assess an imaging technology, especially with respect to its ability to adequately visualize the morphology of the lesions, which is a critical factor in the benign versus malignant classification of a lesion detected in screening mammography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereo-Video Data Reduction of Wake Vortices and Trailing Aircrafts

This report presents stereo image theory and the corresponding image processing software developed to analyze stereo imaging data acquired for the wake-vortex hazard flight experiment conducted at NASA Langley Research Center. In this experiment, a leading Lockheed C-130 was equipped with wing-tip smokers to visualize its wing vortices, while a trailing Boeing 737 flew into the wake vortices of the leading airplane. A Rockwell OV-10A airplane, fitted with video cameras under its wings, flew at 400 to 1000 feet above and parallel to the wakes, and photographed the wake interception process for the purpose of determining the three-dimensional location of the trailing aircraft relative to the wake. The report establishes the image-processing tools developed to analyze the video flight-test data, identifies sources of potential inaccuracies, and assesses the quality of the resultant set of stereo data reduction.

Alter-Gartenberg, Rachel↗

Photon detection with parallel asynchronous processing

An approach to photon detection with a parallel asynchronous signal processor is described. The visible or IR photon-detection capability of the silicon p(+)-n-n(+) detectors and the parallel asynchronous processing are addressed separately. This approach would permit an independent analog processing channel to be dedicated to every pixel. A laminar architecture consisting of a stack of planar arrays of the devices would form a 2D array processor with a 2D array of inputs located directly behind a focal-plane detector array. A 2D image data stream would propagate in neuronlike asynchronous pulse-coded form through the laminar processor. Such systems can integrate image acquisition and image processing. Acquisition and processing would be performed concurrently as in natural vision systems. The possibility of multispectral image processing is addressed.

Coon, D. D.↗

Technical Note: Impact on detective quantum efficiency of edge angle determination method by International Electrotechnical Commission methodology for cardiac x-ray image detectors

Purpose: Cardiac x-ray detectors are used to acquire moving images in real-time for angiography and interventional procedures. Detective quantum efficiency (DQE) is not generally measured on these dynamic detectors; the required “for processing” image data and control of x-ray settings have not been accessible. By 2016, USA hospital physicists will have the ability to measure DQE and will likely utilize the International Electrotechnical Commission (IEC) standard for measuring DQE of dynamic x-ray imaging devices. The current IEC standard requires an image of a tilted tungsten edge test object to obtain modulation transfer function (MTF) for DQE calculation. It specifies the range of edge angles to use; however, it does not specify a preferred method to determine this angle for image analysis. The study aimed to answer the question “will my choice in method impact my results?” Four different established edge angle determination methods were compared to investigate the impact on DQE. Methods: Following the IEC standard, edge and flat field images were acquired on a cardiac flat-panel detector to calculate MTF and noise power spectrum, respectively, to determine DQE. Accuracy of the methods in determining the correct angle was ascertained using a simulated edge image with known angulations. Precision of the methods was ascertained using variability of MTF and DQE, calculated via bootstrapping. Results: Three methods provided near equal angles and the same MTF while the fourth, with an angular difference of 6%, had a MTF lower by 3% at 1.5 mm{sup −1} spatial frequency and 8% at 2.5 mm{sup −1}; corresponding DQE differences were 6% at 1.5 mm{sup −1} and 17% at 2.5 mm{sup −1}; differences were greater than standard deviations in the measurements. Conclusions: DQE measurements may vary by a significant amount, depending on the method used to determine the edge angle when following the IEC standard methodology for a cardiac x-ray detector. The most accurate and precise methods are recommended for absolute assessments and reproducible measurements, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development Of Software To Recognize Parts Of Plants

Report describes first phase in development of digital image-processing subsystem recognizing parts of plants. Subsystem part of robotic system tending and harvesting plants in automated plant-growth chamber. Initial focus on image-processing software that distinguishes among seed heads, stems, and leaves of wheat plants and further distinguishes between these parts and background. Software adaptable to other types of plants.

Despain, Ronald R.↗

Predicting Switchgrass Biomass Yields Using a Spectral Vegetation Index Derived from Multispectral Satellite Imagery

Successful scaling of perennial bioenergy crop production requires a landscape design that optimizes the benefits of finite lands for people, communities, and environments. Utilizing marginal areas is the key to sustainable bioenergy crop production (Ssegane et al., 2015, 2016). Marginal areas are often small-sized lands and unevenly distributed across the agricultural landscape (Ssegane et al., 2016); thus, a systematic, semi-automated remote sensing method is needed as an effective means of estimating bioenergy crop yields across landscapes. Argonne National Laboratory (Argonne) is currently developing a tool, Scaling Up Perennial Bioenergy Economics and Ecosystem Services Tool (SUPERBEEST), to identify marginal agricultural lands and quantify environmental and economic effects of perennial bioenergy crop production systems. The tool aims to provide users a path to foster the sustainable and productive integration of bioenergy crops in the Midwestern agricultural landscape. Reliable, cost-effective, and timely estimation of bioenergy crop yields using remote sensing would help calculate and track the success of integrated bioenergy crops in the landscape for those communities. Argonne previously conducted feasibility studies for estimating biomass yields for bioenergy feedstock, corn and perennial grass using spectral vegetation indices (SVIs)1 derived from optical imagery (Hamada et al., 2015, 2021). In both studies, SVIs, more specifically those sensitive to plant chlorophyll or nitrogen contents, showed potential for estimating or predicting biomass yields with a correlation of determination (R2) ranging from 0.54 to 0.96, indicating a value for further investigation as a viable means of quantifying bioenergy feedstock production across large landscapes. Thus, the goal of this study is to evaluate the feasibility of use of SVIs as a means of estimating or predicting switchgrass biomass yields at harvest using publicly available multispectral satellite imagery. The feasibility analysis was performed using four study areas of mature switchgrass located in Virginia. Objectives are to (1) examine the SVIs and establish their relationships with switchgrass biomass yields at harvest, (2) develop a parsimonious image processing model for predicting at-harvest yields by applying the relationships with the most promising spectral index and (3) map switchgrass yields predicted by the image processing model across the study sites. The calibration to field data will rely on switchgrass biomass yields determined by the baling method, representing a potential challenge to the analysis but an important practical aspect for future applications. With this research design, the study aimed to gain insights into enabling remote sensing-based estimation of bioenergy crop yields in a reliable, cost- effective, and timely manner across large, heterogeneous landscapes.

09 BIOMASS FUELS↗

X-ray computed tomography-based porosity analysis: Algorithms and application for porous woody biomass

The properties of lignocellulosic biomass, such as bulk physical, thermal, and mechanical properties, as well as the mobility of enzymes or catalysts, are largely affected by porosity, pore structures, and pore size distribution. While X-ray computed tomography (CT) has been introduced to effectively produce 3D volumetric images of material microstructure, a quantitative porosity analysis from the 3D images has never been done. This work introduces a first-of-its-kind X-ray CT-based quantitative porosity analysis method and applies the developed toolkit to characterize the internal porosity distribution of loblolly pine. A sample loblolly pine chip was scanned by a nano-resolution X-ray CT system and digitally reconstructed after a sequence of image processing operations. Here, a comprehensive porosity analysis was then performed to quantify the envelope porosity, the spatial distribution of local porosity, and the directional porosity. Solutions to the various challenges in image processing, porosity calculation, and large data handling are provided.

42 ENGINEERING↗

X-ray microtomography

In this tutorial, we describe X-ray microtomography as a technique to nondestructively characterize material microstructure in three dimensions at a micron level spatial resolution. While commercially available laboratory scale instrumentation is available, we focus our attention on synchrotron-based systems, where we can exploit a high flux, monochromatic X-ray beam to produce high fidelity three-dimensional images. A brief description of the physics and the mathematical analysis behind the technique is followed by example applications to specific materials characterization problems, with a particular focus on the utilization of three-dimensional image processing that can be used to extract a wide range of useful information.

36 MATERIALS SCIENCE↗

Revealing asymmetries in the HD 181327 debris disk: A recent massive collision or interstellar medium warping

New multi-roll coronagraphic images of the HD 181327 debris disk obtained using the Space Telescope Imaging Spectrograph on board the Hubble Space Telescope reveal the debris ring in its entirety at high signal-to-noise ratio and unprecedented spatial resolution. We present and apply a new multi-roll image processing routine to identify and further remove quasi-static point-spread function-subtraction residuals and quantify systematic uncertainties. We also use a new iterative image deprojection technique to constrain the true disk geometry and aggressively remove any surface brightness asymmetries that can be explained without invoking dust density enhancements/deficits. The measured empirical scattering phase function for the disk is more forward scattering than previously thought and is not well-fit by a Henyey-Greenstein function. The empirical scattering phase function varies with stellocentric distance, consistent with the expected radiation pressured-induced size segregation exterior to the belt. Within the belt, the empirical scattering phase function contradicts unperturbed debris ring models, suggesting the presence of an unseen planet. The radial profile of the flux density is degenerate with a radially varying scattering phase function; therefore estimates of the ring's true width and edge slope may be highly uncertain. We detect large scale asymmetries in the disk, consistent with either the recent catastrophic disruption of a body with mass >1% the mass of Pluto, or disk warping due to strong interactions with the interstellar medium.

79 ASTRONOMY AND ASTROPHYSICS↗

A new photometric correction technique for the IUE final archive

A substantial fraction of the noise in reduced International Ultraviolet Explorer data is shown to result from limitations of the image processing methods used. An improved method for photometrically correcting spectral images that will be used in the IUE final archive processing software is described. An image processed with this photometric correction software is shown to have not only lower noise overall, but none of the periodic changes in noise amplitude. The improvement that is realized through the approach not only solves a long standing difficulty with IUE data reduction techniques, but substantially enhances the quality of the IUE archive.

Shaw, Richard A.↗

New approach to terahertz diagnostics of human psychoemotional state

A new approach to terahertz (THz) diagnostics of the human psychoemotional state is proposed, based on the analysis of the THz contribution to the total signal while simultaneously recording the IR and THz emissions from the human body (hereinafter referred to as the IR – THz image). The developed image-processing algorithm allows extraction of the informative contribution determined by the THz radiation from the total signal perceived by the recording system. Simultaneous registration of the IR – THz images of the human face and the psychophysiological indicators are carried out in situations of physical stress (short-term intense physical exercise – squats functional test), electrical stimulation, and information stress (cognitive load – simple arithmetic mental calculations). The obtained data are compared with those of similar measurements at rest. It is shown that using cluster analysis of IR – THz images it is possible to divide the test subjects into classes according to the type of reaction of the circulatory system under stressful conditions. (paper)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NEW TECHNIQUES FOR HIGH-CONTRAST IMAGING WITH ADI: THE ACORNS-ADI SEEDS DATA REDUCTION PIPELINE

We describe Algorithms for Calibration, Optimized Registration, and Nulling the Star in Angular Differential Imaging (ACORNS-ADI), a new, parallelized software package to reduce high-contrast imaging data, and its application to data from the SEEDS survey. We implement several new algorithms, including a method to register saturated images, a trimmed mean for combining an image sequence that reduces noise by up to {approx}20%, and a robust and computationally fast method to compute the sensitivity of a high-contrast observation everywhere on the field of view without introducing artificial sources. We also include a description of image processing steps to remove electronic artifacts specific to Hawaii2-RG detectors like the one used for SEEDS, and a detailed analysis of the Locally Optimized Combination of Images (LOCI) algorithm commonly used to reduce high-contrast imaging data. ACORNS-ADI is written in python. It is efficient and open-source, and includes several optional features which may improve performance on data from other instruments. ACORNS-ADI requires minimal modification to reduce data from instruments other than HiCIAO. It is freely available for download at www.github.com/t-brandt/acorns-adi under a Berkeley Software Distribution (BSD) license.

79 ASTRONOMY AND ASTROPHYSICS↗

The simulation of 3D mass models in 2D digital mammography and breast tomosynthesis

Purpose: This work proposes a new method of building 3D breast mass models with different morphological shapes and describes the validation of the realism of their appearance after simulation into 2D digital mammograms and breast tomosynthesis images. Methods: Twenty-five contrast enhanced MRI breast lesions were collected and each mass was manually segmented in the three orthogonal views: sagittal, coronal, and transversal. The segmented models were combined, resampled to have isotropic voxel sizes, triangularly meshed, and scaled to different sizes. These masses were referred to as nonspiculated masses and were then used as nuclei onto which spicules were grown with an iterative branching algorithm forming a total of 30 spiculated masses. These 55 mass models were projected into 2D projection images to obtain mammograms after image processing and into tomographic sequences of projection images, which were then reconstructed to form 3D tomosynthesis datasets. The realism of the appearance of these mass models was assessed by five radiologists via receiver operating characteristic (ROC) analysis when compared to 54 real masses. All lesions were also given a breast imaging reporting and data system (BIRADS) score. The data sets of 2D mammography and tomosynthesis were read separately. The Kendall's coefficient of concordance was used for the interrater observer agreement assessment for the BIRADS scores per modality. Further paired analysis, using the Wilcoxon signed rank test, of the BIRADS assessment between 2D and tomosynthesis was separately performed for the real masses and for the simulated masses. Results: The area under the ROC curves, averaged over all observers, was 0.54 (95% confidence interval [0.50, 0.66]) for the 2D study, and 0.67 (95% confidence interval [0.55, 0.79]) for the tomosynthesis study. According to the BIRADS scores, the nonspiculated and the spiculated masses varied in their degrees of malignancy from normal (BIRADS 1) to highly suggestive for malignancy (BIRADS 5) indicating the required variety of shapes and margins of these models. The assessment of the BIRADS scores for all observers indicated good agreement based on Kendall's coefficient for both the 2D and the tomosynthesis evaluations. The paired analysis of the BIRADS scores between 2D and tomosynthesis for each observer revealed consistent behavior for the real and simulated masses. Conclusions: A database of 3D mass models, with variety of shapes and margins, was validated for the realism of their appearance for 2D digital mammography and for breast tomosynthesis. This database is suitable for use in future observer performance studies whether in virtual clinical trials or in patient images with simulated lesions.

60 APPLIED LIFE SCIENCES↗

SU-D-201-03: Imaging Cellular Pharmacokinetics of 18F-FDG in Inflammatory/Stem Cells

Purpose: Atherosclerosis is a progressive inflammatory condition that underlies coronary artery disease (CAD)—the leading cause of death in the USA. Thus, understating the metabolism of inflammatory cells can be a valuable tool for investigating CAD. To the best of our knowledge, we are the first to successfully investigate the pharmacokinetics of [18F]fluoro-deoxyglucose (18F-FDG) uptake in a single macrophages and compared with induced pluripotent stem cells (iPSCs) and mesenchymal stem cells (MSCs) with a novel imaging technique, radioluminescence microscopy, initially developed for cancer imaging. Methods: Live cells were cultured sparsely on Matrigel in a glass-bottom dish and starved for 1 hour before incubation with 250 microCi of 18F-FDG for 45 minutes. Excess radiotracer was removed using DMEM medium without glucose. Before imaging, DMEM (1 mL) was added to the cell culture and a 100 microm-thin CdWO4 scintillator plate was placed on top of the cells. Light produced following beta decay was imaged with a highly sensitive inverted microscope (LV200, Olympus) fitted with a 40x/1.3 high-NA oil objective, and an EM-CCD camera. The images were collected over 18,000 frames with 4×4 binning (1200 MHz EM Gain, 300ms exposure). Custom-written software was developed in MATLAB for image processing (Figure 1). For statistical analysis 10 different region-of-interests (ROIs) were selected for each cell type. Results: Figures 2A–2B show bright-field/fusion images for all three different cell types. The relationship between cell-to-cell comparisons was found to be linear for macrophages unlike iPSCs and MSCs, which were best fitted with moving or rolling average (Figure 2C). The average observed decay of 18F-FDG in a single cell of MSCs per second (0.067) was 20% and 36% higher compared to iPSCs (0.054) and macrophages (0.043), respectively (Figure 2D). Conclusion: MSCs was found to be 2–3x more sensitive to glucose molecule despite constant parameters for each cell type examined.

60 APPLIED LIFE SCIENCES↗

Evaluation of sucrose crystallization kinetics using confocal microscopy: Determining differences in sucrose crystallization kinetics between single and polycrystal studies

Sucrose solution crystal growth kinetics are dependent on temperature, concentration, and impurities. A double polarized confocal microscopy system was used to obtain photographs with high contrast between growing crystals and the background for color background removal image processing. Seeded solutions of 72 wt% sucrose at 27, 35, 45, and 55°C were compared for single and polycrystals. Polycrystal analysis was determined to offer more rapid image processing and to be more applicable to systems in real operating conditions, while single-crystal analysis was determined to give more comprehensive descriptions of individual crystal behavior at the cost of slower processing.

36 MATERIALS SCIENCE↗

Enhancement Of Penetrant-Inspection Images

Proposed computerized video system processes images of fluorescent dyes absorbed in flaws in welds. Video camera, held by operator or by remote manipulator, views weld illuminated by visible white and ultraviolet light. Images of penetrating dye in cracks and voids in weld joint appear on video monitor. Fluorescent features enhanced by software to facilitate identification of true flaws and record important data.

Wilson, Rhonda C.↗

Engraving Print Classification

A print is a mark, or drawing, made in or upon a plate, stone, woodblock or other material which is cover with ink and then is press usually into a paper reproducing the image on the paper. Engraving prints usually are image composed of a group of binary lines, specially those are made with relief and intaglio techniques. Varying the number and the orientation of lines, the drawing of the engraving print is conformed. For this reason we propose an application based on image processing methods to classify engraving prints.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗