Search NASA⌕ Search

SEARCH · Search NASA

Results for “response surface methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Magnetic Coupling of the Toroidal Plasma with External Asymmetries

A general analytical solution of the coupling problem is proposed which is based on the first-principle equations and standard operations of the electromagnetic theory. This allows direct calculation of the plasma-produced magnetic field after calculating the perturbed plasma equilibrium. The described method leads to the desired result in a more simple and direct way than those used in earlier applications such as coupling of linear MHD solvers to 3D codes for the computation of eddy currents in the metallic structures surrounding the plasma and studying the plasma response to external magnetic perturbations. To facilitate the use of the coupling equations, they are presented in several forms: in terms of the magnetic field, through its scalar potential in vacuum, and via the equivalent surface current. The reduction of the coupling equations is shown from the full toroidal formulation to the cylindrical single-mode limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of three-wavelength CCD image pyrometer used for the temperature field measurements of continuous casting billets

This paper develops an imaging based three-color pyrometer for the monitoring of temperature distribution in a continuous casting billet. A novel optical device, together with an embedded electronic system, is designed to sequentially collect a dark image and three thermal images with specified wavelengths on a same monochromatic charge-coupled-device (CCD). The three thermal images provide the basis for the determination of target temperature, while the dark image is used to online eliminate the dark noise of CCD with a differential method. This image pyrometer is not only independent of target emissivity but also overcomes the dissimilarity of measuring accuracy between the micro-sensors of CCD resulted from the non-uniformity of pixels’ intensity response and the vignetting of optical system. Furthermore, a precise two-color temperature field measuring model on the CCD pyrometer is established, based on which a self-adaptive light-integration mechanism is presented. Compared with the traditional fixed light-integration method, the measuring range of the pyrometer is greatly extended and its sensitivity in low temperature segment is improved. The test results in a steel factory demonstrate that the pyrometer is capable of meeting the requirement of surface temperature measurements about casting billets. Reliability and accuracy of measurement results are also discussed herein.

42 ENGINEERING↗

Combined thermographic phosphor and digital image correlation (TP + DIC) for simultaneous temperature and strain measurements

We report thermographic phosphors (TP) are combined with stereo digital image correlation (DIC) in a novel diagnostic, TP + DIC, to measure full-field surface strains and temperatures simultaneously. The TP + DIC method is presented, including corrections for nonlinear CMOS camera detectors and generation of pixel-wise calibration curves to relate the known temperature to the ratio of pixel intensities between two distinct wavelength bands. Additionally, DIC is employed not only for strain measurements but also for accurate image registration between the two cameras for the two-colour ratio method approach of phosphoric thermography. TP + DIC is applied to characterize the thermo-mechanical response of 304L stainless steel dog bones during tensile testing at different strain rates. The dog bones are patterned for DIC with Mg 3 F 2 GeO 4 :Mn (MFG) via aerosol deposition through a shadow mask. Temperatures up to 425°K (150°C) and strains up to 1.0 mm/mm are measured in the localized necking region, with conservative noise levels of 10°K and 0.01 mm/mm or less. Finally, TP + DIC is compared to the more established method of combining infrared (IR) thermography with DIC (IR + DIC), with results agreeing favourably. Three topics of continued research are identified, including cracking of the aerosol-deposited phosphor DIC features, incomplete illumination for pixels on the border of the phosphor features, and phosphor emission evolution as a function of applied substrate strain. This work demonstrates the combination of phosphor thermography and DIC and lays the foundation for further development of TP + DIC for testing in combined thermo-mechancial environments.

304L stainless steel↗

Dilute Paramagnetism and Non-Trivial Topology in Quasicrystal Approximant Fe4Al13

A very fundamental property of both weakly and strongly interacting materials is the nature of their magnetic response. In this work, we detail the growth of crystals of the quasicrystal approximant Fe4Al13 with an Al flux solvent method. We characterize our samples using electrical transport and heat capacity, yielding results consistent with a simple non-magnetic metal. However, magnetization measurements portray an extremely unusual response for a dilute paramagnet and do not exhibit the characteristic Curie behavior expected for a weakly interacting material at high temperature. Electronic structure calculations confirm metallic behavior but also indicate that each isolated band near the Fermi energy hosts non-trivial topologies, including strong, weak, and nodal components, with resultant topological surface states distinguishable from bulk states on the (001) surface. With half-filled flat bands apparent in the calculation, but an absence of long-range magnetic order, the unusual quasi-paramagnetic response suggests the dilute paramagnetic behavior in this quasicrystal approximant is surprising and may serve as a test of the fundamental assumptions that are taken for granted for the magnetic response of weakly interacting systems.

Avers, Keenan E. (ORCID:0000000223441939)↗

Radial impurity flux measuring method with plasma heating in general geometry

Devising a means to measure the radial impurity flux across the pedestal could be used to reduce impurity accumulation, if not prevent it while providing natural fueling, and thus improving fusion performance in tokamaks. We employ a novel solution procedure that takes advantage of the poloidal flow measurement to obtain the radial impurity flux directly from available diagnostics, such as charge exchange recombination spectroscopy and Thomson scattering. In the absence of our procedure a computationally demanding kinetic calculation of the full bulk ion response would be required at finite aspect ratio for the flux surface shape of interest. The more general form of the model considered here permits large toroidal impurity flow on the order of the impurity thermal speed. Moreover, it allows plasma heating techniques to be employed to actively modify the poloidal variation of the potential to adjust the location of impurity accumulation and thereby alter the radial impurity flux.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementation of radiochromic film dosimetry protocol for volumetric dose assessments to various organs during diagnostic CT procedures

Purpose: The authors present a means to measure high-resolution, two-dimensional organ dose distributions in an anthropomorphic phantom of heterogeneous tissue composition using XRQA radiochromic film. Dose distributions are presented for the lungs, liver, and kidneys to demonstrate the organ volume dosimetry technique. XRQA film response accuracy was validated using thermoluminescent dosimeters (TLDs). Methods: XRQA film and TLDs were first exposed at the center of two CTDI head phantoms placed end-to-end, allowing for a simple cylindrical phantom of uniform scatter material for verification of film response accuracy and sensitivity in a computed tomography (CT) exposure geometry; the TLD and film dosimeters were exposed separately. In a similar manner, TLDs and films were placed between cross-sectional slabs of a 5 yr old anthropomorphic phantom's thorax and abdomen regions. The anthropomorphic phantom was used to emulate real pediatric patient geometry and scatter conditions. The phantom consisted of five different tissue types manufactured to attenuate the x-ray beam within 1%-3% of normal tissues at CT beam energies. Software was written to individually calibrate TLD and film dosimeter responses for different tissue attenuation factors, to spatially register dosimeters, and to extract dose responses from film for TLD comparison. TLDs were compared to film regions of interest extracted at spatial locations corresponding to the TLD locations. Results: For the CTDI phantom exposure, the film and TLDs measured an average difference in dose response of 45%(SD{+-}2%). Similar comparisons within the anthropomorphic phantom also indicated a consistent difference, tracking along the low and high dose regions, for the lung (28%) (SD{+-}8%) and liver and kidneys (15%) (SD{+-}4%). The difference between the measured film and TLD dose values was due to the lower response sensitivity of the film that arose when the film was oriented with its large surface area parallel to the main axis of the CT beam. The consistency in dose response difference allowed for a tissue specific correction to be applied. Once corrected, the average film response agreed to better than 3%(SD{+-}2%) for the CTDI scans, and for the anthropomorphic phantom scans: 3%(SD{+-}3%) for the lungs, 5%(SD{+-}3%) for the liver, and 4%(SD{+-}3%) for the kidneys. Additionally, XRQA film measured a heterogeneous dose distribution within the organ volumes. The extent of the dose distribution heterogeneity was not measurable with the TLDs due to the limitation on the number of TLDs loadable in the regions of the phantom organs. In this regard, XRQA film demonstrated an advantage over the TLD method by discovering a 15% greater maximum dose to lung in a region unmeasured by TLDs. Conclusions: The films demonstrated a lower sensitivity to absorbed dose measurements due to the geometric inefficiency of measuring dose from a beam situated end-on to the film. Once corrected, the film demonstrated equivalent dose measurement accuracy as TLD detectors with the added advantage of relatively simple measurement of high-resolution dose distributions throughout organ volumes.

60 APPLIED LIFE SCIENCES↗

Transfer of microstructure pattern of CNTs onto flexible substrate using hot press technique for sensing applications

Graphical abstract: - Highlights: • Successfully transfer of microstructure patterned CNTs on PET substrate. • Demonstrate as resistor-based NH{sub 3} gas sensor in the sub-ppm range. • Excellent photodetector having instantaneous response and recovery characteristics. • An effective technique to grow and produce flexible electronic device. - Abstract: In this work, we report the successful and efficient transfer process of two- dimensional (2-D) vertically aligned carbon nanotubes (CNTs) onto polyethylene terephthalate (PET) substrate by hot pressing method with an aim to develop flexible sensor devices. Carbon nanotubes are synthesized by cold wall thermal chemical vapor deposition using patterned SiO{sub 2} substrate under low pressure. The height of the pattern of CNTs is controlled by reaction time. The entire growth and transfer process is carried out within 30 min. Strong adhesion between the nanotube and polyethylene terephthalate substrate was observed in the post-transferred case. Raman spectroscopy and scanning electron microscope (SEM) studies are used to analyze the microstructure of carbon nanotube film before and after hot pressing. This technique shows great potential for the fabrication of flexible sensing devices. We report for the first time, the application of patterned microstructure developed by this technique in the development of gas sensor and optoelectronic device. Surface resistive mode is used for detection of ammonia (NH{sub 3}) gas in the sub-ppm range. An impressive photoconducting response is also observed in the visible wavelength. The reproducibility of the sample was checked and the results indicate the possibility of use of carbon nanotube as gas sensor, photodetector, CCDs etc.

36 MATERIALS SCIENCE↗

Monitoring CO 2 Storage at Cranfield, Mississippi with Time-Lapse Offset VSP – Using Integration and Modeling to Reduce Uncertainty

A time-lapse Offset Vertical Seismic Profile (OVSP) data set was acquired as part of a subsurface monitoring program for geologic sequestration of CO 2 . The storage site at Cranfield, near Natchez, Mississippi, is part of a detailed area study (DAS) site for geologic carbon sequestration operated by the U.S. Dept. of Energy’s Southeast Regional Carbon Sequestration Partnership (SECARB). The DAS site includes three boreholes, an injection well and two monitoring wells. The project team selected the DAS site to examine CO 2 sequestration multiphase fluid flow and pressure at the interwell scale in a brine reservoir. The time-lapse (TL) OVSP was part of an integrated monitoring program that included well logs, crosswell seismic, electrical resistance tomography and 4D surface seismic. The goals of the OVSP were to detect the CO 2 induced change in seismic response, give information about the spatial distribution of CO 2 near the injection well and to help tie the high-resolution borehole monitoring to the 4D surface data. The VSP data were acquired in well CFU 31-F1, which is the ~3200 m deep CO 2 injection well at the DAS site. A preinjection survey was recorded in late 2009 with injection beginning in December 2009, and a post injection survey was conducted in Nov 2010 following injection of about 250 kT of CO 2 . The sensor array for both surveys was a 50-level, 3-component, Sercel MaxiWave system with 15 m (49 ft) spacing between levels. The source for both surveys was an accelerated weight drop, with different source trucks used for the two surveys. Consistent time-lapse processing was applied to both data sets. Time-lapse processing generated difference corridor stacks to investigate CO 2 induced reflection amplitude changes from each source point. Corridor stacks were used for amplitude analysis to maximize the signal-to-noise ratio (S/N) for each shot point. Spatial variation in reflectivity (used to ‘map’ the plume) was similar in magnitude to the corridor stacks but, due to relatively lower S/N, the results were less consistent and more sensitive to processing and therefore are not presented. We examined the overall time-lapse repeatability of the OVSP data using three methods, the NRMS and Predictability (Pred) measures of Kragh and Christie (2002) and the signal-to-distortion ratio (SDR) method of Cantillo (2011). Because time-lapse noise was comparable to the observed change, multiple methods were used to analyze data reliability. The reflections from the top and base reservoir were identified on the corridor stacks by correlation with a synthetic response generated from the well logs. A consistent change in the corridor stack amplitudes from pre- to post-CO 2 injection was found for both the top and base reservoir reflections on all ten shot locations analyzed. In addition to the well-log synthetic response, a finite-difference elastic wave propagation model was built based on rock/fluid properties obtained from well logs, with CO 2 induced changes guided by time-lapse crosswell seismic tomography (Ajo-Franklin, et al., 2013) acquired at the DAS site. Time-lapse seismic tomography indicated that two reservoir zones were affected by the flood. The modeling established that interpretation of the VSP trough and peak event amplitudes as reflectivity from the top and bottom of reservoir is appropriate even with possible tuning effects. Importantly, this top/base change gives confidence in an interpretation that these changes arise from within the reservoir, not from bounding lithology. The modeled time-lapse change and the observed field data change from 10 shotpoints are in agreement for both magnitude and polarity of amplitude change for top and base of reservoir. Therefore, we conclude the stored CO 2 has been successfully detected and, furthermore, the observed seismic reflection change can be applied to Cranfield’s 4D surface seismic for spatially delineating the CO 2 /brine interface.

54 ENVIRONMENTAL SCIENCES↗

The In Situ Ion Irradiation Toolbox: Time-Resolved Structure and Property Measurements

Abstract The dynamic interactions of ions with matter drive a host of complex evolution mechanisms, requiring monitoring on short spatial and temporal scales to gain a full picture of a material response. Understanding the evolution of materials under ion irradiation and displacement damage is vital for many fields, including semiconductor processing, nuclear reactors, and space systems. Despite materials in service having a dynamic response to radiation damage, typical characterization is performed post-irradiation, washing out all information from transient processes. Characterizing active processes in situ during irradiation allows the mechanisms at play during the dynamic ion-material interaction process to be deciphered. In this review, we examine the in situ characterization techniques utilized for examining material structure, composition, and property evolution under ion irradiation. Covering analyses of microstructure, surface composition, and material properties, this work offers a perspective on the recent advances in methods for in situ monitoring of materials under ion irradiation, including a future outlook examining the role of complementary and combined characterization techniques in understanding dynamic materials evolution.

36 MATERIALS SCIENCE↗

Effects of Irradiation on Brain Vasculature Using an In Situ Tumor Model

Purpose: Damage to normal tissue is a limiting factor in clinical radiotherapy (RT). We tested the hypothesis that the presence of tumor alters the response of normal tissues to irradiation using a rat in situ brain tumor model. Methods and Materials: Intravital microscopy was used with a rat cranial window to assess the in situ effect of rat C6 glioma on peritumoral tissue with and without RT. The RT regimen included 40 Gy at 8 Gy/day starting Day 5 after tumor implant. Endpoints included blood-brain barrier permeability, clearance index, leukocyte-endothelial interactions and staining for vascular endothelial growth factor (VEGF) glial fibrillary acidic protein, and apoptosis. To characterize the system response to RT, animal survival and tumor surface area and volume were measured. Sham experiments were performed on similar animals implanted with basement membrane matrix absent of tumor cells. Results: The presence of tumor alone increases permeability but has little effect on leukocyte-endothelial interactions and astrogliosis. Radiation alone increases tissue permeability, leukocyte-endothelial interactions, and astrogliosis. The highest levels of permeability and cell adhesion were seen in the model that combined tumor and irradiation; however, the presence of tumor appeared to reduce the volume of rolling leukocytes. Unirradiated tumor and peritumoral tissue had poor clearance. Irradiated tumor and peritumoral tissue had a similar clearance index to irradiated and unirradiated sham-implanted animals. Radiation reduces the presence of VEGF in peritumoral normal tissues but did not affect the amount of apoptosis in the normal tissue. Apoptosis was identified in the tumor tissue with and without radiation. Conclusions: We developed a novel approach to demonstrate that the presence of the tumor in a rat intracranial model alters the response of normal tissues to irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Highly Rectifying Fluidic Diodes Based on Asymmetric Layer-by-Layer Nanofilms on Nanochannel Membranes

Nanochannel-based fluidic diodes display ion selectivity and ion-current rectification (ICR), which may prove important in energy harvesting and biosensors. This paper reports asymmetric functionalization of the outer surface of a flexible nanochannel polymer membrane to create fluidic diodes that give ICR. Layer-by-layer (LbL) adsorption with cross-linking of only the underlying part of the polyelectrolyte nanofilm leads to a porosity step across the film. The combination of a high effective surface-charge density and the porosity step in the film leads to a remarkable maximum ICR factor of ~200 with a pH gradient across the film. Incorporation of pH-sensitive polyelectrolyte components enables the ICR factor to increase an order of magnitude on going from pH 8 to pH 3. Furthermore, the coated membrane shows excellent anion-selectivity. Thus, LbL adsorption with partial cross-linking provides a simple method for creating coated nanochannel membranes that serve as pH-responsive ionic diodes for potential chemical/biosensors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-T-329: Characteristic Study of a Rado-Photoluminescenct Glass Dosimeter with Accumulated Dose

Purpose: This study investigated the effect of accumulated dose on radiophotoluminescent glass dosimeter in megavoltage photon. Methods: 45 commercially-available radio-photoluminescence glass dosimeters (RPLGD; GD-302M, Asahi Techno Glass Co., Shizuoka, JAPAN) were irradiated to 10 × 10 cm{sup 2} open-field with 6, 10 and 15 MV photon beams at 100 cm of source to surface distance and dose maximum depths. Each energy has consists of five groups which is consists of three detectors. A group #1 and #2 was irradiated about 1 Gy to 100 Gy, and estimated the integral dose response with and without annealing procedure. A group #3 was read the dose after irradiated 10 Gy of dose by 10 times repeatedly to estimate the fading effect of RPLGD. A group #4 and #5 was produced same ways with different irradiation dose such as 50 Gy for group #4 and 100 Gy for group #5. Results: From the results of group #1 and #2, an annealed detector shows linear response to integral dose but other detectors without the annealing process, has supra linearity for integral dose especially close to 100 Gy dose. For group #3, #4 and #5, the dose response of repeated irradiation, the dose response was decreased about 15%, 12% and 7% for 6 MV, 10 MV and 15MV. Conclusion: It was found that RPLGD response to accumulated dose was supra linear and this respond was altered with amount of accumulated dose to the RPLGD. In addition, the fading effect need to be concern with RPLGD.

36 MATERIALS SCIENCE↗

Statistical abstraction of high-fidelity CO2 pressure histories in 2-D, uniform, cylindrical domains

Long-term, deep, geologic sequestration of carbon dioxide (CO{sub 2}) is being evaluated as a world-wide strategy for limiting anthropogenic carbon emissions to the atmosphere. A key element of this evaluation is quantification of the ancillary risks associated with this fundamentally new linkage between the global energy economy and the subsurface ecosphere. Quantitative risk assessment methods traditionally enumerate operational scenarios and describe the multiple physical responses that may ensue from each scenario depending on the quality of information that is available to describe identified system dependencies. For example, multiplepoint injection of compressed CO{sub 2} into a geologic reservoir having a nominal stratigraphy will create a pressurized zone of liquid that migrates through the rock. Scenarios that postulate CO{sub 2} encountering previously undetected wells or natural fractures in the caprock that represent leakage paths to the surface must be treated in a probabilistic format that accommodates unknown details in the subsurface geology. Fluid pressure in the reservoir at the location of the potential transport path drives any potential leakage that might occur, so the spatial and temporal distribution of CO{sub 2} overpressure represents an important metric for numeric simulation. State-of-the-art geologic transport models like FEHM, TUFF, and ECLIPSE (Refs. 1, 2, 3) can accurately simulate multi phase gas migration in a fully characterized geologic domain. However, each simulation can require time periods ranging between minutes and hours to achieve acceptable numerical performance, so it is often impractical to link predictive physics models directly in a quantitative risk assessment that will require transport estimates for thousands of scenarios. When direct computation is not possible, a library of high-fidelity calculations can sometimes be distilled to a simplified statistical correlation that spans the variability in all relevant input parameters while retaining acceptable accuracy in the key predicted qu antities. Essentially, numerical calculations can be used as data for an exploratory trend analysis just as one might regress predictive equations against laboratory measurements to determine unknown parameter values. Statistical correlations are derived here to reproduce radial overpressure as a function of time and position for CO{sub 2} injected along the centerline of cylindrical geologic domains. FEHM was used to compute two-phase pressure histories in a suite of simulations that varied (1) initial pressure, (2) vertical reservoir thickness, (3) domain radius, (4) uniform permeability, and (5) mass injection rate. The simulations include both a 50-yr injection phase and a 50-yr relaxation phase. The correlations are based on a two-step fitting paradigm that first captures the shape of an entire radial pressure profile for a given time and input condition, and then correlates the shape parameters as generalized power products of 6 dimensionless parameters. Estimated overpressures are accurate within a factor of 1.25 compared to the suite of simulated values. The correlations can be used to evaluate rapidly local temporal overpressure for any continuous values within the defined space of input parameters. Inversion of the pressure correlation is also demonstrated to determine the maximum injection rate corresponding to an assumed limiting fracture pressure.

54 ENVIRONMENTAL SCIENCES↗

Multi-modality nanoparticles having optically responsive shape

In certain embodiments novel nanoparticles (nanowontons) are provided that are suitable for multimodal imaging and/or therapy. In one embodiment, the nanoparticles include a first biocompatible (e.g., gold) layer, an inner core layer (e.g., a non-biocompatible material), and a biocompatible (e.g., gold) layer. The first gold layer includes a concave surface that forms a first outer surface of the layered nanoparticle. The second gold layer includes a convex surface that forms a second outer surface of the layered nanoparticle. The first and second gold layers encapsulate the inner core material layer. Methods of fabricating such nanoparticles are also provided.

36 MATERIALS SCIENCE↗

How Do We Know That Human Activities Have Influenced Global Climate?

Human activities have significantly altered not only the chemical composition of Earth's atmosphere, but also the climate system. Human influences have led to increases in well-mixed greenhouse gases, decreases in stratospheric ozone, and changes in the atmospheric burdens of sulfate and soot aerosols. All of these atmospheric constituents interact with incoming solar and outgoing terrestrial radiation. Human-induced changes in the concentrations of these constituents modify the natural radiative balance of Earth's atmosphere, and therefore perturb climate. Quantifying the size of the human effect on climate is a difficult statistical problem. "Fingerprint" methods are typically used for this purpose. These methods involve rigorous statistical comparisons of modeled and observed climate change patterns. Fingerprinting assumes that each individual influence on climate has a unique signature in climate records. The climate fingerprints in response to different forcing factors are typically estimated with computer models, which can be used to perform the controlled experiments that we cannot conduct in the real world. One criticism of the findings of previous scientific assessments is that they have relied heavily on fingerprint studies involving changes in near-surface temperature. Recent fingerprint work, however, has considered a variety of other climate variables, such as ocean heat content, stratospheric temperatures, Northern Hemisphere sea ice extent, sea level pressure, atmospheric water vapor, and the height of the tropopause. These studies illustrate that a human-induced climate change signal is identifiable in many different variables and geographic regions, and that the climate system is telling us an internally- and physically-consistent story.

54 ENVIRONMENTAL SCIENCES↗

Radial impurity flux measuring method with plasma heating in general geometry

We report devising a means to measure the radial impurity flux across the pedestal could be used to reduce impurity accumulation, if not prevent it while providing natural fueling, and thus improving fusion performance in tokamaks. We employ a novel solution procedure that takes advantage of the poloidal flow measurement to obtain the radial impurity flux directly from available diagnostics, such as charge exchange recombination spectroscopy and Thomson scattering. In the absence of our procedure, a computationally demanding kinetic calculation of the full bulk ion response would be required at finite aspect ratio for the flux surface shape of interest. The more general form of the model considered here permits large toroidal impurity flow on the order of the impurity thermal speed. Moreover, it allows plasma heating techniques to be employed to actively modify the poloidal variation of the potential to adjust the location of impurity accumulation and thereby alter the radial impurity flux.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physics of direct-contact ultrasonic cloth drying process

Existing methods of drying fabrics involve energy-intensive thermal evaporation of moisture from clothes. Drying fabrics using high-frequency vibrations of piezoelectric transducers can substantially reduce drying time and energy consumption. In this method, vibrational energy generates instability on the liquid-air interface and mechanically ejects water from a wet fabric. For the first time, the physics of the ultrasonic fabric drying process in direct-contact mode is studied. The kinematic and thermal responses of water droplets and fabrics on piezoelectric crystal transducers and metal mesh–based transducers are studied. The results suggest that on piezoelectric crystal transducers, the response of a droplet subjected to ultrasonic excitation is dictated by the relative magnitude of the surface tension and the ultrasonic excitation forces. The drying process for a fabric on the studied transducers consists of two regimes—vibrational and thermal. When the water content is high, the vibrational forces can eject bulk water rapidly. But the more strongly bound water within the smaller fabric pores evaporates by the thermal energy generated as a result of the viscous losses. Our study finds that a metal mesh–based transducer is more suitable for dewatering fabrics, as it facilitates the ejection of water from the fabric–transducer interface to the opposite side of the mesh. A demonstration unit developed consumes 10–20% of the water latent heat energy at water contents greater than 20%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding the Role of Interfaces for Water Management in Platinum Group Metal-Free Electrodes in Polymer Electrolyte Fuel Cells

For this study, a systematic analysis, both experimental and model-assisted, has been performed over three main configurations of platinum group metal-free (PGM-free) electrodes in polymer electrolyte fuel cells (PEFCs): Catalyst-coated membrane CCM technology is being compared to the gas-diffusion electrode (GDE) method of electrode fabrication and juxtaposed to a hybrid/combined GDE-CCM method of membrane-electrode assembly (MEA) fabrication. The corresponding electrodes were evaluated for their electrochemical performance, modeled, and studied with in situ and operando X-ray computed tomography (X-ray CT). The study establishes that through-thickness inhomogeneities play the most important role in water withdrawal/water management and affect most significantly PGM-free PEFC performance. The catalyst integration technique results in formation of interfacial regions with increased porosity and surface roughness. These regions form critical interfaces de facto responsible for flooding type behavior of the PEFC as shown for a first time by operando X-ray CT. The computational model shows that the PEFC performance critically depends on liquid water formation and transport at cold and wet conditions.

25 ENERGY STORAGE↗