Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Electrical conductivity measurements on silicate melts using the loop technique

A new method is described for measurement of the electrical conductivity of silicate melts under controlled oxygen partial pressure at temperatures to 1550 C. The melt samples are suspended as droplets on platinum-rhodium loops, minimizing iron loss from the melt due to alloying with platinum, and providing maximum surface exposure of the melt to the oxygen-buffering gas atmosphere. The latter provides extremely rapid equilibration of the melt with the imposed oxygen partial pressure. The loop technique involves a minimum of setup time and cost, provides reproducible results to within + or - 5% and is well suited to electrical conductivity studies on silicate melts containing redox cations.

Waff, H. S.↗

Multicolor pyrometer for materials processing in space

The program goals are to design, construct, and program a prototype imaging pyrometer capable of measuring the temperature distribution across the surface of a moving object suspended in space. The approach is to utilize an optical system which operates at short wavelengths compared to the peak of the blackbody spectrum for the temperature range of interest, thus minimizing errors associated with a lack of knowledge about heated sample emissivity. An analysis of the system's temperature measurement capability based on the camera's responsivity was performed and bound to be satisfactory. Details for the evolving optical design and the progress towards construction of a working model are discussed. Details of the algorithm developed for selecting the optimum colors to be used by the pyrometer are reported. Though final selection of the colors will have to await a final design of the optical system, results using a preliminary optical design are presented.

Frish, Michael↗

Over-Expression, Purification and Crystallization of Human Dihydrolipoamide Dehydrogenase

Dehydrolipoamide dehydrogenase (E3; dihydrolipoan-tide:NAD+ oxidoreductase, EC 1.8.1.4) is a common catalytic component found in pyruvate dehydrogenase complex, alpha-ketoglutarate dehydrogenase complex, and branched-chain cc-keto acid dehydrogenase complex. E3 is also a component (referred to as L protein) of the glycine cleavage system in bacterial metabolism (2). Active E3 forms a homodimer with four distinctive subdomain structures (FAD binding, NAD+ binding, central and interface domains) with non-covalently but tightly bound FAD in the holoenzyme. Deduced amino acids from cloned full-length human E3 gene showed a total of 509 amino acids with a leader sequence (N-terminal 35 amino acids) that is excised (mature form) during transportation of expressed E3 into mitochondria membrane. So far, three-dimensional structure of human E3 has not been reported. Our effort to achieve the elucidation of the X-ray crystal structure of human E3 will be presented. Recombinant pPROEX-1 expression vector (from GIBCO BRL Life Technologies) having the human E3 gene without leader sequence was constructed by Polymerase Chain Reaction (PCR) and subsequent ligation, and cloned in E.coli XL1-Blue by transformation. Since pPROEX-1 vector has an internal His-tag (six histidine peptide) located at the upstream region of a multicloning site, one-step affinity purification of E3 using nickelnitriloacetic acid (Ni-NTA) agarose resin, which has a strong affinity to His-tag, was feasible. Also a seven-amino-acid spacer peptide and a recombinant tobacco etch virus protease recognition site (seven amino acids peptide) found between His-tag and first amino acid of expressed E3 facilitated the cleavage of His-tag from E3 after the affinity purification. By IPTG induction, ca. 15 mg of human E3 (mature form) was obtained from 1L LB culture with overnight incubation at 25C. Over 98% of purity of E3 from one-step Ni-NTA agarose affinity purification was confirmed by SDS-PAGE analysis. For crystallization, E3 samples were prepared with and without His-tag. To minimize the aggregation of E3, apo- and holo- forms of E3s were tested, as well as a mutated E3. Dynamic light scattering measurements revealed that the E3 preparations without His-tag and substrate are highly monodispersive with regard to homodimers. Consequent crystallization trials of this E3 preparation led to single crystals of E3 grown by the vapor diffusion method. Crystals were obtained within a few days from solution containing poly (ethylene glycol) monomethyl ether 5000 as a precipitant. Autoindexing and integration of the X-ray diffraction data showed that E3 crystals belong to an orthorhombic system with unit cell parameters a-- 123. 1, b= 165.3 and c=214.3A. Further optimization of protein preparation and crystallization experiments for the structural determination will be discussed.

Hong, Y. S.↗

Comparison of Shortwave Cloud Radiative Forcing Derived from ARM SGP Surface and GOES-8 Satellite Measurements During ARESE I and ARESE II

One of the objectives of the ARM Enhanced Shortwave Experiment (ARESE) is to investigate the absorption of solar radiation by clouds over the ARM Southern Great Plains central facility. A variety of techniques employing various combinations Of Surface, aircraft, and satellite data have been used to estimate the absorption empirically. During ARESE-I conducted during fall 1995, conflicting results were produced from different analyses of the combined datasets leading to the need for a more controlled experiment. ARESE-II was conducted during spring 2000. Improved calibrations, different sampling strategies, and broadband satellite data were all available to minimize some of the sources of uncertainty in the data. In this paper, cloud absorption or its parametric surrogates (e.g., Cess et al. 1995) are derived from collocated and coincident surface and satellite radiometer data from both ARESE-I and ARESE-II using the latest satellite and surface instrument calibrations.

Rapp, A. D.↗

Determination of Small Animal Long Bone Properties Using Densitometry

Assessment of bone structural property changes due to loading regimens or pharmacological treatment typically requires destructive mechanical testing and sectioning. Our group has accurately and non-destructively estimated three dimensional cross-sectional areal properties (principal moments of inertia, Imax and Imin, and principal angle, Theta) of human cadaver long bones from pixel-by-pixel analysis of three non-coplanar densitometry scans. Because the scanner beam width is on the order of typical small animal diapbyseal diameters, applying this technique to high-resolution scans of rat long bones necessitates additional processing to minimize errors induced by beam smearing, such as dependence on sample orientation and overestimation of Imax and Imin. We hypothesized that these errors are correctable by digital image processing of the raw scan data. In all cases, four scans, using only the low energy data (Hologic QDR-1000W, small animal mode), are averaged to increase image signal-to-noise ratio. Raw scans are additionally processed by interpolation, deconvolution by a filter derived from scanner beam characteristics, and masking using a variable threshold based on image dynamic range. To assess accuracy, we scanned an aluminum step phantom at 12 orientations over a range of 180 deg about the longitudinal axis, in 15 deg increments. The phantom dimensions (2.5, 3.1, 3.8 mm x 4.4 mm; Imin/Imax: 0.33-0.74) were comparable to the dimensions of a rat femur which was also scanned. Cross-sectional properties were determined at 0.25 mm increments along the length of the phantom and femur. The table shows average error (+/- SD) from theory of Imax, Imin, and Theta) over the 12 orientations, calculated from raw and fully processed phantom images, as well as standard deviations about the mean for the femur scans. Processing of phantom scans increased agreement with theory, indicating improved accuracy. Smaller standard deviations with processing indicate increased precision and repeatability. Standard deviations for the femur are consistent with those of the phantom. We conclude that in conjunction with digital image enhancement, densitometry scans are suitable for non-destructive determination of areal properties of small animal bones of comparable size to our phantom, allowing prediction of Imax and Imin within 2.5% and Theta within a fraction of a degree. This method represents a considerable extension of current methods of analyzing bone tissue distribution in small animal bones.

Breit, Gregory A.↗

Bacterial Degradation of Plastics

Plastics are not only a major component of societies on Earth but also those in Space. After use, plastics can accumulate and become difficult to recycle or reuse. Finding ways to degrade and recycle synthetic plastics would provide a way to reduce the upmass of Space Travel, create a closed-loop system of resources and even benefit life on Earth. The purpose of this project is to identify and characterize bacterial species that can degrade and recycle plastics. It has been suggested that bacteria can use plastics, like polyethylene and polystyrene, as a carbon source. These plastics are broken down into intermediary molecules which can then be used in the bacterium's metabolism. Environmental samples were collected from various locations rich in plastic waste. These samples are currently being used to culture bacteria in M9 minimal media containing polyethylene and polystyrene beads as the sole carbon source. High Performance Liquid Chromatography (HPLC), Scanning Electron Microscopy (SEM), and DNA sequencing are among the various methods that will be used identify and characterize bacteria that can degrade plastics. The results from these experiments will provide methods to reduce waste of plastics and ultimately improve sustainability for long-term space exploration.

plastic conversion↗

The Dragonfly Entry and Descent System

Dragonfly is a proposed New Frontiers class mission that will send a nuclear powered octocopter to the surface of Titan for an extended science mission. This presentation will provide an overview of the Entry and Descent system that is under development to ensure the save delivery of this unique "relocatable lander" to Titan. Titan's dense atmosphere, large atmospheric scale height, and low gravity allows for a slow-paced entry and descent sequence that lasts more than 100 minutes, as opposed to the "7 minutes of terror" that is charac-teristic of landed Mars missions. This slow pace al-lows for sufficient temporal separation between critical events of the EDL sequence to minimize overall risk.The Dragonfly entry and descent system is composed of high-heritage components, minimizing overall risk. The aeroshell will be a scaled Genesis Sample Return capsule with a diameter of 3.75 meters, built by Lock-heed Martin. The thermal protection system (TPS) is made up of Phenolic Impregnated Carbon Ablator-Domestic (PICA-D) on the heatshield, SLA-561V on the backshell, and SLA-220M on the aft cover and low gain antenna. Each material has extensive heritage for the chosen application. The spacecraft will enter Titan at a velocity of 7.3 km/s, resulting in a predicted fully margined stagnation point heating environment of 254 W/cm2 heat rate and 13 kJ/cm2 heat load, well within the tested limits of the chosen materials. The aeroheat-ing environments, including the significant contribu-tion of shock layer radiation from CN on both the heatshield and backshell, are evaluated using state of the art models and codes that have been validated with appropriate ground testing.Once the deceleration pulse is complete, a disk-gap-band (DGB) drogue parachute will be deployed at ap-proximately Mach 1.5 to stabilize and further deceler-ate the spacecraft. Due to the dense atmosphere, the spacecraft will spend more than 80 minutes on this parachute, until reaching an appropriate altitude to de-ploy the subsonic main parachute. The lander is re-leased after approximately 17 minutes on the main chute before releasing and transitioning to powered flight in order to navigate to its first landing site. The release of the lander from the backshell effectively ends the entry and descent portion of the mission.The full presentation will provide additional details about the design of the EDL system hardware, engi-neering design, and overall con-ops. Preliminary aero-thermal and TPS sizing analyses will be presented, and the parachute system will be described in greater detail. In addition, the Dragonfly spacecraft will carry an En-gineering Science Investigation (ESI) package designed to obtain engineering data during EDL that will be used to validate the design methodology for future missions. An overview of the proposed ESI package will also be presented.

EDL↗

Effects of hand soldering MIL-PRF 55365 tantalum capacitors

Different values of MIL-PRF-55365 tantalum capacitors were subjected to three different types of soldering conditions— Convection Reflow, JPL Standard Hand Soldering, and Optimized Hand Soldering. The electrical parameters for a large number of capacitors of each value were measured before and after thermal soldering stress. The results indicate that tantalum capacitors subjected to convection reflow conditions experience detectable changes in electrical parameters; capacitors subjected to hand solder conditions show reduced changes in electrical parameters when compared to the reflow samples. Optimized hand solder conditions are shown to have a minimal effect on electrical parameters.

Sheldon, Douglas↗

Reweighted ℓ{sub 1} minimization method for stochastic elliptic differential equations

We consider elliptic stochastic partial differential equations (SPDEs) with random coefficients and solve them by expanding the solution using generalized polynomial chaos (gPC). Under some mild conditions on the coefficients, the solution is “sparse” in the random space, i.e., only a small number of gPC basis makes considerable contribution to the solution. To exploit this sparsity, we employ reweighted l{sub 1} minimization to recover the coefficients of the gPC expansion. We also combine this method with random sampling points based on the Chebyshev probability measure to further increase the accuracy of the recovery of the gPC coefficients. We first present a one-dimensional test to demonstrate the main idea, and then we consider 14 and 40 dimensional elliptic SPDEs to demonstrate the significant improvement of this method over the standard l{sub 1} minimization method. For moderately high dimensional (∼10) problems, the combination of Chebyshev measure with reweighted l{sub 1} minimization performs well while for higher dimensional problems, reweighted l{sub 1} only is sufficient. The proposed approach is especially suitable for problems for which the deterministic solver is very expensive since it reuses the sampling results and exploits all the information available from limited sources.

97 MATHEMATICS AND COMPUTING↗

Motion mitigation for lung cancer patients treated with active scanning proton therapy

Purpose: Motion interplay can affect the tumor dose in scanned proton beam therapy. This study assesses the ability of rescanning and gating to mitigate interplay effects during lung treatments. Methods: The treatments of five lung cancer patients [48 Gy(RBE)/4fx] with varying tumor size (21.1–82.3 cm{sup 3}) and motion amplitude (2.9–30.6 mm) were simulated employing 4D Monte Carlo. The authors investigated two spot sizes (σ ∼ 12 and ∼3 mm), three rescanning techniques (layered, volumetric, breath-sampled volumetric) and respiratory gating with a 30% duty cycle. Results: For 4/5 patients, layered rescanning 6/2 times (for the small/large spot size) maintains equivalent uniform dose within the target >98% for a single fraction. Breath sampling the timing of rescanning is ∼2 times more effective than the same number of continuous rescans. Volumetric rescanning is sensitive to synchronization effects, which was observed in 3/5 patients, though not for layered rescanning. For the large spot size, rescanning compared favorably with gating in terms of time requirements, i.e., 2x-rescanning is on average a factor ∼2.6 faster than gating for this scenario. For the small spot size however, 6x-rescanning takes on average 65% longer compared to gating. Rescanning has no effect on normal lung V{sub 20} and mean lung dose (MLD), though it reduces the maximum lung dose by on average 6.9 ± 2.4/16.7 ± 12.2 Gy(RBE) for the large and small spot sizes, respectively. Gating leads to a similar reduction in maximum dose and additionally reduces V{sub 20} and MLD. Breath-sampled rescanning is most successful in reducing the maximum dose to the normal lung. Conclusions: Both rescanning (2–6 times, depending on the beam size) as well as gating was able to mitigate interplay effects in the target for 4/5 patients studied. Layered rescanning is superior to volumetric rescanning, as the latter suffers from synchronization effects in 3/5 patients studied. Gating minimizes the irradiated volume of normal lung more efficiently, while breath-sampled rescanning is superior in reducing maximum doses to organs at risk.

60 APPLIED LIFE SCIENCES↗

Nondestructive detection and characterization of carbonation in concrete

Exposure of concrete to the environment leads to changes in composition, microstructure, and properties; these effects often start from the surface of a concrete structure. A specific, widespread environmental effect is carbonation, where carbon dioxide penetrates the surface of concrete and reacts with calcium hydroxide that is a product of Portland cement hydration in concrete. Carbonation is of interest not only because it can lead to the initiation of reinforcement corrosion, but also carbon is increasingly used during curing to alter the surface properties of cement-based materials as a method to 'sink' carbon in cement-based materials. Nonlinear Rayleigh surface wave measurements are performed on uncarbonated and carbonated concrete samples to assess any mechanical changes induced by carbonation,. In order to minimize the effects of contact conditions, the generated signals are detected by a noncontact air-coupled transducer (100 kHz) at locations along the propagation axis. The nonlinearity parameter, β is used to quantitatively characterize the degree of carbonation. To more accurately analyze the data, corrections are made for the effects of attenuation and diffraction. A comparison between the carbonated and uncarbonated samples demonstrates that pores and micro-cracks are affected by the carbonation product and these significantly change the measured nonlinearity parameter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Damage Tolerance Assessment of Laser Clad Repairs of Coarse Grain Ti-6Al-4V

Background: Laser cladding offers a promising approach to repairing aviation components, with the ability to restore the geometric shape and the static and fatigue strength. Objective: The damage tolerance of a coarse grain Ti-6Al-4 V material is assessed via three sets of samples: (i) baseline, (ii) laser clad repaired, and (iii) laser cladding followed by heat treatment. Method: The specimens were subjected to fatigue loading using a marker band technique, in which cracks initiated from pre-defined laser slots and the small crack growth rates were measured by quantitative fractography. Additional characterization was performed on these samples, including hardness measurements, microstructure analysis, and multimodal residual stress analyses. Results: The region of the specimen undergoing laser cladding exhibited higher hardness values and a compressive residual stress, based on the slitting method. The samples subjected to heat treatment after cladding displayed negligible differences in grain size and minimal residual stress relaxation. Conclusions: The results demonstrated significant variability, with data demonstrating that cracks in the laser clad region (exhibiting the largest compressive residual stress) grew faster than cracks in the substrate region of the sample or in the baseline cases. Finally, these counterintuitive results are rationalized with additional analyses from synchrotron-based energy dispersive X-ray diffraction and high energy X-ray diffraction, demonstrating significant spatial variability in the residual elastic strains in the millimeter-sized prior β grains within the material.

36 MATERIALS SCIENCE↗

Identification and Removal of Contaminant Sequences From Ribosomal Gene Databases: Lessons From the Census of Deep Life

Earth’s subsurface environment is one of the largest, yet least studied, biomes on Earth, and many questions remain regarding what microorganisms are indigenous to the subsurface. Through the activity of the Census of Deep Life (CoDL) and the Deep Carbon Observatory, an open access 16S ribosomal RNA gene sequence database from diverse subsurface environments has been compiled. However, due to low quantities of biomass in the deep subsurface, the potential for incorporation of contaminants from reagents used during sample collection, processing, and/or sequencing is high. Thus, to understand the ecology of subsurface microorganisms (i.e., the distribution, richness, or survival), it is necessary to minimize, identify, and remove contaminant sequences that will skew the relative abundances of all taxa in the sample. In this meta-analysis, we identify putative contaminants associated with the CoDL dataset, recommend best practices for removing contaminants from samples, and propose a series of best practices for subsurface microbiology sampling. The most abundant putative contaminant genera observed, independent of evenness across samples, were Propionibacterium, Aquabacterium, Ralstonia, and Acinetobacter. While the top five most frequently observed genera were Pseudomonas, Propionibacterium, Acinetobacter, Ralstonia, and Sphingomonas. The majority of the most frequently observed genera (high evenness) were associated with reagent or potential human contamination. Additionally, in DNA extraction blanks, we observed potential archaeal contaminants, including methanogens, which have not been discussed in previous contamination studies. Such contaminants would directly affect the interpretation of subsurface molecular studies, as methanogenesis is an important subsurface biogeochemical process. Utilizing previously identified contaminant genera, we found that ~27% of the total dataset were identified as contaminant sequences that likely originate from DNA extraction and DNA cleanup methods. Thus, controls must be taken at every step of the collection and processing procedure when working with low biomass environments such as, but not limited to, portions of Earth’s deep subsurface. Taken together, we stress that the CoDL dataset is an incredible resource for the broader research community interested in subsurface life, and steps to remove contamination derived sequences must be taken prior to using this dataset.

16S rRNA↗

Picosecond-resolved X-ray absorption spectroscopy at low signal contrast using a hard X-ray streak camera

A picosecond-resolving hard-X-ray streak camera has been in operation for several years at Sector 7 of the Advanced Photon Source (APS). Several upgrades have been implemented over the past few years to optimize integration into the beamline, reduce the timing jitter, and improve the signal-to-noise ratio. These include the development of X-ray optics for focusing the X-rays into the sample and the entrance slit of the streak camera, and measures to minimize the amount of laser light needed to generate the deflection-voltage ramp. For the latter, the photoconductive switch generating the deflection ramp was replaced with microwave power electronics. With these, the streak camera operates routinely at 88 MHz repetition rate, thus making it compatible with all of the APS fill patterns including use of all the X-rays in the 324-bunch mode. Sample data are shown to demonstrate the performance.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Mission Concept for a Europa Lander

A NASA HQ-directed study team led by the Jet Propulsion Laboratory (JPL) with partners including Applied Physics Lab, Marshall Space Flight Center, Goddard Space Flight Center, Langley Research Center and Sandia National Laboratory has recently presented a mission concept for a Europa Lander that would search for bio-signatures and signs of life in the near-subsurface of the Jovian moon. The mission would follow the Europa Clipper multiple-flyby mission, planned for launch in June of 2022, which would provide reconnaissance imagery and other data to the Lander for use in selecting a scientifically compelling site and certifying it for engineering safety. The Europa Lander concept accommodates the Model Payload identified by the Europa Lander Science Definition Team (SDT) and documented in the Europa Lander Study 2016 Report released in February of 2017. The currently envisioned Europa Lander would launch on an SLS Block 1B as early as October of 2025 into a VEGA trajectory, arriving in the Jovian system as early as July of 2030. The baseline design of the integrated flight system includes a dedicated Carrier and Relay Stage, a Deorbit Vehicle composed of a Deorbit Stage consisting of a solid rocket motor (SRM), an MSL-like sky-crane Descent Stage, and a Lander which accommodates the instrument suite. The Lander would be powered by primary batteries over a 20-day surface mission. The science goals envisioned by the SDT require five samples taken from a depth of 10cm, a depth chosen to ensure minimal radiation processing of the potential biomarkers. Mission challenges include the large launch mass, unknown terrain topography, surface composition and materials properties, the high radiation environment, and complying with stringent planetary protection requirements. The mission concept uses a strategy of early risk reduction and overlapping requirements to provide robustness to harsh and uncertain environments. Early risk reduction efforts are aimed at maturing technologies associated with the sampling system, the intelligent landing system, high specific energy batteries, low mass and power motor controllers, and a thermal sterilization system.

Dooley, Jennifer↗

Method and apparatus for background signal reduction in opto-acoustic absorption measurement

The sensitivity of an opto-acoustic absorption detector is increased to make it possible to measure trace amounts of constituent gases. A second beam radiation path is created through the sample cell identical to a first path except as to length, alternating the beam through the two paths and minimizing the detected pressure difference for the two paths while the beam wavelength is tuned away from the absorption lines of the sample. Then with the beam wavelength tuned to the absorption line of any constituent of interest, the pressure difference is a measure of trace amounts of the constituent. The same improved detector may also be used for measuring the absorption coefficient of known concentrations of absorbing gases.

Rosengren, L. G.↗

SAIL-Isotopologue (SAIL-iso) Field Campaign Report

The SAIL-iso project took place from November 19, 2022 to June 3, 2023 as part of the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Surface Atmosphere Integrated Field Laboratory (SAIL) project at the main project site in Gothic, Colorado. The project sought to use measurements of the stable isotopic composition of water vapor to better understand cloud-aerosol interactions in a remote mountainous watershed. Water vapor isotopologue and humidity measurements were determined using a Los Gatos Research Triple Water Vapor Isotope Analyzer (TWVIA). The instrument was deployed in the guest van and consists of three main components: a water vapor isotope analyzer, a Los Gatos Research Water Vapor Isotope Standard Source (WVISS), and a Los Gatos Research Dry Air Source. Ambient air samples were collected through an inlet located about one meter above roof of the shipping container. Samples were then delivered to the analyzer through Teflon tubing by use of an external pump to minimize the transport time between the inlet and analyzer. The inlet tubing was surrounded by a Briskheat heat trace and insulating material to ensure ambient air samples did not fall below the dew point and result in condensation. The analyzer uses cavity ringdown spectroscopy to report isotopic ratios of ambient air samples at a frequency of 1 Hz. The calibration unit of the instrument was used in conjunction with the dry air source to periodically measure the δ values of standard waters. It uses a nebulizer to push small water droplets into a hot chamber that vaporizes the water without fractionation. This vapor was then transported to the analyzer using a built-in compressor and the dry air source, which allows each standard with known δ values to be measured at a wide range of humidity values for post-measurement calibration of ambient air samples. Multiple sources of uncertainty are introduced at different stages during the data collection and processing. These include (1) instrument precision, (2) uncertainty in the secondary standards, (3) humidity-correction uncertainty, and (4) Vienna Standard Mean Ocean Water – Standard Light Antarctic Precipitation (VSMOW-SLAP) calibration uncertainty. Uncertainty from each step is propagated in quadrature to calculate a total uncertainty of each isotopologue. Uncertainty was determined to be 2.3‰ for δD and 0.4‰ for δ 18 O.

54 ENVIRONMENTAL SCIENCES↗

Water vapor isotopic composition during TRACER IOP

The TRACER-Iso project took place from June 1 to September 30, 2022 as part of the intensive observation period (IOP) of the Tracking Aerosol Convection Interactions (TRACER) project at the main project site at the La Porte, Texas, municipal airport. The project sought to use measurements of the stable isotopic composition of water vapor to better understand cloud-aerosol interactions in deep convection in a polluted urban setting. Water vapor isotopologue and humidity measurements were determined using a Picarro L2130 Water Vapor Isotope Analyzer. The instrument was deployed in the guest van and consists of three main components: a water vapor isotope analyzer, and a Los Gatos Research Water Vapor Isotope Standard Source (WVISS), and a Los Gatos Research Dry Air Source. Ambient air samples were collected through an inlet located about one meter above roof of the shipping container. Samples were then delivered to the analyzer through teflon tubing by use of an external pump to minimize the transport time between the inlet and analyzer. The inlet tubing was surrounded by a Briskheat heat trace and insulating material to ensure ambient air samples did not fall below the dew point and result in condensation. The analyzer uses cavity ringdown spectroscopy to report isotopic ratios of ambient air samples at a frequency of 1 Hz. The calibration unit of the instrument was used in conjunction with the dry air source to periodically measure the δ values of standard waters. It uses a nebulizer to push small water droplets into a hot chamber that vaporizes the water without fractionation. This vapor was then transported to the analyzer using a built-in compressor and the dry air source, which allows each standard with known δ values to be measured at a wide range of humidity values for post-measurement calibration of ambient air samples. There are multiple sources of uncertainty introduced at different stages during the data collection and processing. These include (1) instrument precision, (2) uncertainty in the secondary standards, (3) humidity-correction uncertainty, and (4) VSMOW-SLAP calibration uncertainty. Uncertainty from each step is propagated in quadrature to calculate a total uncertainty of each isotopologue. Uncertainty was determined to be 2.3‰ for δD and 0.4‰ for δ18O.

54 ENVIRONMENTAL SCIENCES↗