Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Sample Complexity of Power System State Estimation using Matrix Completion: Preprint

In this paper, we propose an analytical framework to quantify the amount of data samples needed to obtain accurate state estimation in a power system-a problem known as \emph{sample complexity} analysis in computer science. Motivated by the increasing adoption of distributed energy resources into the distribution-level grids, it becomes imperative to estimate the state of distribution grids in order to ensure stable operation. Traditional power system state estimation techniques mainly focus on the transmission network which involve solving an overdetermined system and eliminating bad data. However, distribution networks are typically \emph{underdetermined} due to the large number of connection points and high cost of pervasive installation of measurement devices. In this paper, we consider the recently proposed state-estimation method for underdetermined systems that is based on \emph{matrix completion}. In particular, a \emph{constrained} matrix completion algorithm was proposed, wherein the standard matrix completion problem is augmented with additional equality constraints representing the physics (namely power-flow constraints). We analyze the sample complexity of this general method by proving an upper bound on the sample complexity that depends directly on the properties of these constraints that can lower number of needed samples as compared to the unconstrained problem. To demonstrate the improvement that the constraints add to state estimation, we test the method on a 141-bus distribution network case study and compare it to the traditional least squares minimization state estimation method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Can Control Banding be better than traditional Industrial Hygiene?

The answer to this question should be 'no' if you can afford it and 'yes' if you cannot. However, Control Banding (CB) is proving itself in areas with uncertainties. This could be either a lack of knowledge--as with nanomaterials or when lacking an OEL--or with the lack or expertise, as can be seen with SMEs and in Economically Developing Countries (EDCs). Over 90% of the world's workers do not have access to occupational safety, health, and hygiene (OSHH) professionals and traditional quantitative risk assessment methods to achieve prevention from acquiring work-related illness and injury. Although risk factors for work-related illness and disease are well known, until the recent growth of CB there had yet to be designed and implemented a comprehensive OSHH process that focuses on achieving minimization of these occupational risk factors for the vast majority of the global workforce. This problem exists for three primary reasons: (1) There are not a sufficient number of trained and qualified OSHH professionals worldwide to attempt to offer comparable levels of traditional services necessary to achieve prevention; (2) The vast majority of OSHH professionals, and the funds to afford their conventional approaches, are concentrated in Developed Countries, such as those in the EU and the US, whereas the greatest need for work-related disease, illness, and injury prevention lies within EDCs; and (3) Even within Developed Countries, the funding to acquire the services of OSHH professionals sits primarily within the largest of industries and governmental institutions. This problem renders a void of occupational risk management for the professions and trades within EDCs and similarly the SMEs within even the richest of Developed Countries. Further, conventional means to achieve such prevention rely heavily on exposure assessment sampling strategies that, although proven successful, are cost-prohibitive in these arenas.

99 GENERAL AND MISCELLANEOUS↗

Cross-Domain Recognition by Identifying Joint Subspaces of Source Domain and Target Domain

This paper introduces here a new method to solve the cross-domain recognition problem. Different from the traditional domain adaption methods which rely on a global domain shift for all classes between the source and target domains, the proposed method is more flexible to capture individual class variations across domains. By adopting a natural and widely used assumption that the data samples from the same class should lay on an intrinsic low-dimensional subspace, even if they come from different domains, the proposed method circumvents the limitation of the global domain shift, and solves the cross-domain recognition by finding the joint subspaces of the source and target domains. Specifically, given labeled samples in the source domain, we construct a subspace for each of the classes. Then we construct subspaces in the target domain, called anchor subspaces, by collecting unlabeled samples that are close to each other and are highly likely to belong to the same class. The corresponding class label is then assigned by minimizing a cost function which reflects the overlap and topological structure consistency between subspaces across the source and target domains, and within the anchor subspaces, respectively. We further combine the anchor subspaces to the corresponding source subspaces to construct the joint subspaces. Subsequently, one-versus-rest support vector machine classifiers are trained using the data samples belonging to the same joint subspaces and applied to unlabeled data in the target domain. We evaluate the proposed method on two widely used datasets: 1) object recognition dataset for computer vision tasks and 2) sentiment classification dataset for natural language processing tasks. Comparison results demonstrate that the proposed method outperforms the comparison methods on both datasets.

97 MATHEMATICS AND COMPUTING↗

Compendium of photovoltaic degradation rates

Abstract Published data on photovoltaic (PV) degradation measurements were aggregated and re‐examined. The subject has seen an increased interest in recent years resulting in more than 11 000 degradation rates in almost 200 studies from 40 different countries. As studies have grown in number and size, we found an impact from sampling bias attributable to size and accuracy. Because of the correlational nature of this study we examined the data in several ways to minimize this bias. We found median degradation for x‐Si technologies in the 0.5–0.6%/year range with the mean in the 0.8–0.9%/year range. Hetero‐interface technology (HIT) and microcrystalline silicon (µc‐Si) technologies, although not as plentiful, exhibit degradation around 1%/year and resemble thin‐film products more closely than x‐Si. Several studies showing low degradation for copper indium gallium selenide (CIGS) have emerged. Higher degradation for cadmium telluride (CdTe) has been reported, but these findings could reflect a convolution of less accurate studies and longer stabilization periods for some products. Significant deviations for beginning‐of‐life measurements with respect to nameplate rating have been documented over the last 35 years. Therefore, degradation rates that use nameplate rating as reference may be significantly impacted. Studies that used nameplate rating as reference but used solar simulators showed less variation than similar studies using outdoor measurements, even when accounting for different climates. This could be associated with confounding effects of measurement uncertainty and soiling that take place outdoors. Hotter climates and mounting configurations that lead to sustained higher temperatures may lead to higher degradation in some, but not all, products. Wear‐out non‐linearities for the worst performing modules have been documented in a few select studies that took multiple measurements of an ensemble of modules during the lifetime of the system. However, the majority of these modules exhibit a fairly linear decline. Modeling these non‐linearities, whether they occur at the beginning‐of‐life or end‐of‐life in the PV life cycle, has an important impact on the levelized cost of energy. Copyright © 2016 John Wiley & Sons, Ltd.

Jordan, Dirk C.↗

PlumeSeeker{sup TM}: A Model-Based Least-Cost Monitoring Network Design Technology for 3-D Contaminant Plume Boundary Delineation - 19582

Delineating the extent of contamination in an aquifer is a pre-requisite for designing remediation schemes as well as for satisfying regulators and stakeholders. Contaminant plumes are typically delineated using either monitoring well locations with observed concentrations below remedial goals or with computer-drawn contour maps based on available concentration measurements in the groundwater. Computer-generated plume information lacks ground truth resulting in uncertainty about the true limits of contamination. The location of groundwater delineation wells is usually chosen solely based on professional judgement and experience. Both approaches can be inefficient, risky and often unnecessarily expensive. PlumeSeeker{sup TM} is a software-based technology well-suited for the optimal delineation of radiological or emerging contaminant plumes with single or multiple source locations. The software is an enhancement of a university research code for plume delineation using geostatistical and stochastic modeling tools integrated with the widely used groundwater flow and transport modeling software MODFLOW-SURFACT{sup TM}. PlumeSeeker{sup TM} increases the overall confidence in the location and geometry of the plume boundary through the sequential (i.e. a rank-ordered listing) or batch (i.e. a suite of multiple wells) selection of existing or new monitoring wells based on the criteria of maximizing plume boundary uncertainty reduction and on new field information. Using PlumeSeeker{sup TM}, remediation managers can optimally locate new wells at sites where well installation costs are high or hydrogeology is complex. Applicable at sites with or without existing monitoring wells, PlumeSeeker{sup TM} is particularly powerful for optimally allocating project resources (labor, well installation, and laboratory costs) between existing wells and sampling at new locations. An application of PlumeSeeker{sup TM} at a DoD installation demonstrates how the cost of delineating a plume can be minimized. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fast and low-dose computed laminography using compressive sensing based technique

Computed laminography (CL) is well known for inspecting microstructures in the materials, weldments and soldering defects in high density packed components or multilayer printed circuit boards. The overload problem on x-ray tube and gross failure of the radio-sensitive electronics devices during a scan are among important issues in CL which needs to be addressed. The sparse-view CL can be one of the viable option to overcome such issues. In this work a numerical aluminum welding phantom was simulated to collect sparsely sampled projection data at only 40 views using a conventional CL scanning scheme i.e. oblique scan. A compressive-sensing inspired total-variation (TV) minimization algorithm was utilized to reconstruct the images. It is found that the images reconstructed using sparse view data are visually comparable with the images reconstructed using full scan data set i.e. at 360 views on regular interval. We have quantitatively confirmed that tiny structures such as copper and tungsten slags, and copper flakes in the reconstructed images from sparsely sampled data are comparable with the corresponding structure present in the fully sampled data case. A blurring effect can be seen near the edges of few pores at the bottom of the reconstructed images from sparsely sampled data, despite the overall image quality is reasonable for fast and low-dose NDT.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Innovative Direct Push Technologies for Characterization of the 216-Z-9 Trench at DOE's Hanford Site

Because of the significant radiological and chemical hazards present at the 216-Z-9 Trench at the US Department of Energy Hanford Site, the only practical subsurface characterization methods are those that minimize or control airborne vapors and particles. This study evaluates and compares the performance of two Direct Push Technologies (Hydraulic Hammer Rig (HHR) and Cone Penetrometer Testing (CPT)) with traditional cable tool drilling in similar difficult geologic conditions. The performance was based on the depth of penetration, the ability to collect representative vadose zone soil samples, the penetration rate, and the relative cost. The HHR achieved deeper penetration depths and faster penetration rates than CPT techniques, while still maintaining the waste minimization benefits of direct push technologies. Although cable tool drilling achieved the deepest penetration, the safety and disposal concerns due to the soil cuttings that were generated made this drilling approach both slow and costly compared to the direct push techniques. (authors)

42 ENGINEERING↗

TU-AB-BRC-11: Moving a GPU-OpenCL-Based Monte Carlo (MC) Dose Engine Towards Routine Clinical Use: Automatic Beam Commissioning and Efficient Source Sampling

Purpose: We have previously developed a GPU-OpenCL-based MC dose engine named goMC with built-in analytical linac beam model. To move goMC towards routine clinical use, we have developed an automatic beam-commissioning method, and an efficient source sampling strategy to facilitate dose calculations for real treatment plans. Methods: Our commissioning method is to automatically adjust the relative weights among the sub-sources, through an optimization process minimizing the discrepancies between calculated dose and measurements. Six models built for Varian Truebeam linac photon beams (6MV, 10MV, 15MV, 18MV, 6MVFFF, 10MVFFF) were commissioned using measurement data acquired at our institution. To facilitate dose calculations for real treatment plans, we employed inverse sampling method to efficiently incorporate MLC leaf-sequencing into source sampling. Specifically, instead of sampling source particles control-point by control-point and rejecting the particles blocked by MLC, we assigned a control-point index to each sampled source particle, according to MLC leaf-open duration of each control-point at the pixel where the particle intersects the iso-center plane. Results: Our auto-commissioning method decreased distance-to-agreement (DTA) of depth dose at build-up regions by 36.2% averagely, making it within 1mm. Lateral profiles were better matched for all beams, with biggest improvement found at 15MV for which root-mean-square difference was reduced from 1.44% to 0.50%. Maximum differences of output factors were reduced to less than 0.7% for all beams, with largest decrease being from1.70% to 0.37% found at 10FFF. Our new sampling strategy was tested on a Head&Neck VMAT patient case. Achieving clinically acceptable accuracy, the new strategy could reduce the required history number by a factor of ∼2.8 given a statistical uncertainty level and hence achieve a similar speed-up factor. Conclusion: Our studies have demonstrated the feasibility and effectiveness of our auto-commissioning approach and new efficient source sampling strategy, implying the potential of our GPU-based MC dose engine goMC for routine clinical use.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mann-Kendall Test for Analysis of Groundwater Contaminant Plume Stability and Evaluation of Sampling Frequency for Long-Term Monitoring - 13233

This paper describes a spreadsheet-based approach for applying the Mann-Kendall (MK) Test to identify statistically significant increasing or decreasing concentration trends, stable concentration trends (not increasing or decreasing), and indeterminate concentration trends (no trend) defined by time-series groundwater monitoring data for inorganic, organic, or radiological contaminants. The approach has been applied in support of ongoing long-term monitoring (LTM) of groundwater contamination at the U.S. Department of Energy (DOE) Y-12 National Security Complex (Y-12) in Oak Ridge, Tennessee and elsewhere on the DOE Oak Ridge Reservation (ORR), and has proven effective at minimizing subjective bias in the evaluation and interpretation of contaminant concentration trend data. Application of the approach for the purposes of optimizing groundwater sampling frequency for LTM also is outlined. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A novel apparatus for in situ compression of submicron structures and particles in a high resolution SEM

We report on the development and characterization of a novel in situ manipulation device to perform stressing experiments on the submicron scale inside a high resolution field emission scanning electron microscope. The instrument comprises two main assembly groups: an upper part for positioning and moving a mounted probe and a force sensor as well as a specimen support as lower part. The upper part consists of a closed loop tripod piezoelectric scanner mounted on a self-locking coarse positioning stage. Two interlocked steel springs and a linear variable differential transformer measuring the springs' deflections compose the lower part of the instrument. This arrangement acts as force-sensor and sample support. In comparison to already well-established concepts a wide measuring range is covered by adjusting the spring constant between 30 N/m and 50000 N/m. Moreover, the new device offers striking advantages with respect to force calibration and sample deformation measurements. Force calibration is performed using the eigenfrequency of the force detection system directly inside the SEM. Deformation data are obtained with high accuracy by simultaneously recording displacements above and below the specimen. The detrimental apparatus compliance is determined, and the influence on measured data subsequently minimized: an easy to validate two-springs-in-series model is used for data correction. A force resolution in normal direction of 100 nN accompanied by a sample deformation resolution of 5 nm can be achieved with the instrument using an appropriate load cell stiffness. The capabilities and versatility of this instrument are exemplified by compression experiments performed on submicron amorphous silica particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synergistic Effect of Nitrogen and Refractory Material on TiN Formation and Equiaxed Grain Structure of Ferritic Stainless Steel

The effect of nitrogen content on the formation of an equiaxed solidification structure of Fe-16Cr steel was investigated. Moreover, two different kinds of refractory materials, i.e., alumina and magnesia, were employed to control the type of oxide inclusion. The characteristics of TiN(-oxide) inclusions were quantitatively analyzed in both molten steel and solidified samples. When the melting was carried out in the alumina refractory, the grain size continuously decreased with increasing nitrogen content. However, a minimum grain size was observed at a specific nitrogen content (approx. 150 ppm) when the steel was melted in the magnesia refractory. Most of the single TiN particles had a cuboidal shape and fine irregularly shaped particles were located along the grain boundary due to the microsegregation of Ti at the grain boundary during solidification. The type of TiN-oxide hybrid inclusion was strongly affected by the refractory material where Al{sub 2}O{sub 3}-TiN and MgAl{sub 2}O{sub 4}-TiN hybrid-type inclusions were obtained in the alumina and magnesia refractory experiments, respectively. The formation of oxide inclusions was well predicted by thermochemical computations and it was commonly found that oxide particles were initially formed, followed by the nucleation and growth of TiN. When the nitrogen content increased, the number density of TiN linearly increased in the alumina refractory experiments. However, the number of TiN exhibits a maximum at about [N] = 150 ppm, at which a minimum grain size was obtained in the magnesia refractory experiments. Therefore, the larger the number density of TiN, the smaller the primary grain size after solidification. The number density of TiN in the steel melted in the magnesia refractory was greater than that in the steel melted in the alumina refractory at given Ti and N contents, which was due to the lower planar lattice disregistry of MgAl{sub 2}O{sub 4}-TiN interface rather than that of Al{sub 2}O{sub 3}-TiN interface. When ∆T{sub TiN} (= difference between the TiN precipitation temperature and the liquidus of the steel) was 20 K to 40 K, the number density of effective TiN was maximized and thus, the grain size was minimized after solidification. Finally, although most of the TiN particles were smaller than 1 μm in the molten steel samples irrespective of the nitrogen content, TiN particles larger than 10 μm were observed in the solidified samples when the nitrogen content was greater than 150 ppm. The growth of TiN particles during melting and solidification was well predicted by the combinatorial simulation of the ‘Ostwald ripening model’ based on the Lifshitz–Slyozov–Wagner theory in conjunction with the ‘Diffusion controlled model’ using Ohnaka’s microsegregation equation.

36 MATERIALS SCIENCE↗

Computing equilibrium free energies through a nonequilibrium quench

Many methods to accelerate sampling of molecular configurations are based on the idea that temperature can be used to accelerate rare transitions. These methods typically compute equilibrium properties at a target temperature using reweighting or through Monte Carlo exchanges between replicas at higher temperatures. A recent paper [G. M. Rotskoff and E. Vanden-Eijnden, Phys. Rev. Lett. 122, 150602 (2019)] demonstrated that accurate equilibrium densities of states can also be computed through a nonequilibrium “quench” process, where sampling is performed at a higher temperature to encourage rapid mixing and then quenched to lower energy states with dissipative dynamics. Here, we provide an implementation of the quench dynamics in LAMMPS and evaluate a new formulation of nonequilibrium estimators for the computation of partition functions or free energy surfaces (FESs) of molecular systems. We show that the method is exact for a minimal model of N-independent harmonic springs and use these analytical results to develop heuristics for the amount of quenching required to obtain accurate sampling. We then test the quench approach on alanine dipeptide, where we show that it gives an FES that is accurate near the most stable configurations using the quench approach but disagrees with a reference umbrella sampling calculation in high FE regions. We then show that combining quenching with umbrella sampling allows the efficient calculation of the free energy in all regions. Moreover, by using this combined scheme, we obtain the FES across a range of temperatures at no additional cost, making it much more efficient than standard umbrella sampling if this information is required. Finally, we discuss how this approach can be extended to solute tempering and demonstrate that it is highly accurate for the case of solvated alanine dipeptide without any additional modifications.

Chemistry↗

Fusibility and sintering characteristics of ash

The temperature characteristics of ash fusibility are studied for a wide range of bituminous and brown coals, lignites, and shales with ratios R{sub B/A} of their alkaline and acid components between 0.03 and 4. Acritical value of R{sub B/A} is found at which the fusion temperatures are minimal. The sintering properties of the ashes are determined by measuring the force required to fracture a cylindrical sample. It is found that the strength of the samples increases sharply at certain temperatures. The alkali metal content of the ashes has a strong effect on their sintering characteristics.

01 COAL, LIGNITE, AND PEAT↗

Impact of sulfation and desulfation on NO x reduction using Cu-chabazite SCR catalysts

This bench reactor study investigates the impact of gaseous sulfur on the NO x reduction activity of Cu-chabazite SCR (Cu-CHA) catalysts at SO 2 concentrations representative of marine diesel engine exhaust. After two hours of 500 ppm SO 2 exposure at 250 and 400 °C in the simulated diesel exhaust gases, the NO x reduction activity of the sulfated Cu-CHA SCR catalysts is severely degraded at evaluation temperatures below 250 °C; however, above 250 °C the impact of sulfur exposure is minimal. EPMA shows that sulfur is located throughout the washcoat and along the entire length of the sulfated samples. Interestingly, BET measurements reveal that the sulfated samples have a 20% decrease in surface area. Moreover, the sulfated samples show a decrease in NO x /nitrate absorption during NO exposure in a DRIFTS reactor which suggests that Cu sites in the catalyst are blocked by the presence of sulfur. SO 2 exposure also results in an increase in NH 3 storage capacity, possibly due to the formation of ammonium sulfate species in the sulfated samples. In all cases, lean thermal treatments as low as 500 °C reverse the effects of sulfur exposure and restore the NO x reduction activity of the Cu-CHA catalyst to that of the fresh condition.

36 MATERIALS SCIENCE↗

Dynamic analysis of apoptosis using cyanine SYTO probes: From classical to microfluidic cytometry

Cell death is a stochastic process, often initiated and/or executed in a multi-pathway/multi-organelle fashion. Therefore, high-throughput single-cell analysis platforms are required to provide detailed characterization of kinetics and mechanisms of cell death in heterogeneous cell populations. However, there is still a largely unmet need for inert fluorescent probes, suitable for prolonged kinetic studies. Here, we compare the use of innovative adaptation of unsymmetrical SYTO dyes for dynamic real-time analysis of apoptosis in conventional as well as microfluidic chip-based systems. We show that cyanine SYTO probes allow non-invasive tracking of intracellular events over extended time. Easy handling and 'stain-no wash' protocols open up new opportunities for high-throughput analysis and live-cell sorting. Furthermore, SYTO probes are easily adaptable for detection of cell death using automated microfluidic chip-based cytometry. Overall, the combined use of SYTO probes and state-of-the-art Lab-on-a-Chip platform emerges as a cost effective solution for automated drug screening compared to conventional Annexin V or TUNEL assays. In particular, it should allow for dynamic analysis of samples where low cell number has so far been an obstacle, e.g. primary cancer stems cells or circulating minimal residual tumors.

60 APPLIED LIFE SCIENCES↗

In-line three-dimensional holography of nanocrystalline objects at atomic resolution

We report that resolution and sensitivity of the latest generation aberration-corrected transmission electron microscopes allow the vast majority of single atoms to be imaged with sub-Ångstrom resolution and their locations determined in an image plane with a precision that exceeds the 1.9-pm wavelength of 300 kV electrons. Such unprecedented performance allows expansion of electron microscopic investigations with atomic resolution into the third dimension. Here we show a general tomographic method to recover the three-dimensional shape of a crystalline particle from high-resolution images of a single projection without the need for sample rotation. The method is compatible with low dose rate electron microscopy, which improves on signal quality, while minimizing electron beam-induced structure modifications even for small particles or surfaces. Lastly, we apply it to germanium, gold and magnesium oxide particles, and achieve a depth resolution of 1–2 Å, which is smaller than inter-atomic distances.

36 MATERIALS SCIENCE↗

Compressive sensing lattice dynamics. I. General formalism

Ab initio calculations have been successfully used for evaluating lattice dynamical properties of solids within the (quasi)harmonic approximation (i.e., assuming noninteracting phonons with infinite lifetimes), but it remains difficult to treat anharmonicity in all but the simplest compounds. We detail a systematic information-theory-based approach to deriving ab initio anharmonic force constants: Compressive sensing lattice dynamics (CSLD). The non-negligible terms that are necessary to reproduce the first-principles calculated interatomic forces are automatically selected by minimizing the ℓ 1 norm (sum of absolute values) of the scaled force constants. Here, by using efficient sampling of the configuration space using a modest number of atomic configurations with quasirandom displacements, CSLD is well suited for deriving accurate anharmonic potentials for complex multicomponent compounds with large unit cells. We demonstrate the power and generality of CSLD by calculating the phonon lifetimes and thermal transport properties of type-I Si clathrates.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Influence of Material Properties on TiO 2 Nanoparticle Agglomeration

Emerging nanomaterials are being manufactured with varying particle sizes, morphologies, and crystal structures in the pursuit of achieving outstanding functional properties. These variations in these key material properties of nanoparticles may affect their environmental fate and transport. To date, few studies have investigated this important aspect of nanoparticles’ environmental behavior. In this study, the aggregation kinetics of ten different TiO 2 nanoparticles (5 anatase and 5 rutile each with varying size) was systematically evaluated. Our results show that, as particle size increases, the surface charge of both anatase and rutile TiO 2 nanoparticles shifts toward a more negative value, and, accordingly, the point of zero charge shifts toward a lower value. The colloidal stability of anatase sphere samples agreed well with DLVO theoretical predictions, where an increase in particle size led to a higher energy barrier and therefore greater critical coagulation concentration. In contrast, the critical coagulation concentration of rutile rod samples correlated positively with the specific surface area, i.e., samples with higher specific surface area exhibited higher stability. Finally, due to the large innate negative surface charge of all the TiO 2 samples at the pH value (pH = 8) tested, the addition of natural organic matter was observed to have minimal effect on TiO 2 aggregation kinetics, except for the smallest rutile rods that showed decreased stability in the presence of natural organic matter.

54 ENVIRONMENTAL SCIENCES↗