Search NASA⌕ Search

SEARCH · Search NASA

Results for “sludge process”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Evaluation of the Impact of Additional Manganese from the Recycle Collection Tank (RCT) Glycolate Destruction Process on Glass Properties

The Defense Waste Processing Facility (DWPF) is planning to implement glycolic acid as a reductant within the waste processing flowsheet. An assessment of the glycolic acid flowsheet has revealed the potential for thermolytic production of hydrogen in the Concentration, Storage and Transfer Facilities (CSTF) from glycolate entrained in the DWPF recycle stream. To mitigate this potential scenario, a glycolate destruction process utilizing sodium permanganate (NaMnO 4 ) is being developed for use in the DWPF Recycle Collection Tank (RCT). The RCT is fed by the Slurry Mix Evaporator Condensate Tank (SMECT) and the Off-Gas Condensate Tank (OGCT). The SMECT could receive glycolate via a foamover from the Sludge Receipt and Adjustment Tank (SRAT) or the Slurry Mix Evaporator (SME), and the OGCT could receive glycolate via carryover of sludge particles in the purge from the melter during surge conditions. The use of NaMnO 4 additions in the RCT will result in additional manganese (Mn) in the waste stream and needs to be evaluated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Proven Uranium Recovery Solutions for the Nuclear Fuel Manufacturing Market - 16060

During the Nuclear Fuel Manufacturing process a number of by-products and residues are generated from various sources. In recent years, Westinghouse has characterised and processed around 50,000 drums of residue comprising of numerous different types generated over 60 years from the manufacture of numerous types of fuel for greater than 50 reactors. These include, AGR, Magnox (uranium metal fuel), PWR, fast reactors and various test reactors. Different organisations have different definitions and names for each of these categories but essentially they fall into one of the following categories: Clean Scrap (U{sub 3}O{sub 8}, UO{sub 2}, UO{sub 3}, UF{sub 4}, powders, pellets), Dirty Scrap (U{sub 3}O{sub 8}, UO{sub 2}, UO{sub 3}, UF{sub 4}, powders, pellets), Gd Contaminated Scrap (U{sub 3}O{sub 8}, UO{sub 2}, powders, pellets), Ash, Sludge, Combustible / soft residues (e.g. ventilation filters, gloves, plastic bags), Contaminated metals (including contaminated scrap zirconium tubes), Materials arising from decommissioning. Routes have been developed across the industry for a number of the categories listed above, however in numerous examples, routes have not been established and materials have been stored creating a significant legacy. Westinghouse understands the issues regarding legacy uranic material and the financial and regulatory impact of storage. Interim storage of materials may seem like a low cost option in the short term; however ongoing costs for facilities, manpower and equipment, without a permanent and final solution can result in significant lifetime material management costs. Recovery of uranium and sending materials for safe disposal of enriched uranium residues is not easy because of the criticality risk both during processing and at a disposal site. Therefore quantities of materials than can be sent via permitted disposal routes are very limited The development of regulations often means that finding solutions is becoming more difficult. It is believed that timely resolution is ultimately the most cost effective solution. In addition, the intrinsic value of recycling this material is also high and in some cases can mitigate the cost of processing. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

GeoMelt{sup R} ICV{sup TM} Treatment of Sellafield Pond Solids Waste - 13414

Kurion, Inc., in partnership with AMEC Ltd., is demonstrating its GeoMelt{sup R} In-Container Vitrification (ICV){sup TM} Technology to Sellafield Ltd. (SL). SL is evaluating the proposition of directly converting a container (skip/box/drum) of raw solid ILW into an immobilized waste form using thermal treatment, such that the resulting product is suitable for interim storage at Sellafield and subsequent disposal at a future Geological Disposal Facility. Potential SL feed streams include sludges, ion-exchange media, sand, plutonium contaminated material, concrete, uranium, fuel cladding, soils, metals, and decommissioning wastes. The solid wastes have significant proportions of metallic constituents in the form of containers, plant equipment, structural material and swarf arising from the nuclear operations at Sellafield. GeoMelt's proprietary ICV process was selected for demonstration, with the focus being high and reactive metal wastes arising from solid ILW material. A composite surrogate recipe was used to demonstrate the technology towards treating waste forms of diverse types and shapes, as well as those considered difficult to process; all the while requiring few (if any) pre-treatment activities. Key strategic objectives, along with their success criterion, were established by SL for this testing, namely: 1. Passivate and stabilize the raw waste simulant, as demonstrated by the entire quantity of material being vitrified, 2. Immobilize the radiological and chemo-toxic species, as demonstrated via indicative mass balance using elemental analyses from an array of samples, 3. Production of an inert and durable product as evidenced by transformation of reactive metals to their inert oxide forms and satisfactory leachability results using PCT testing. Two tests were performed using the GeoMelt Demonstration Unit located at AMEC's Birchwood Park Facilities in the UK. Post-melt examination of the first test indicated some of the waste simulant had not fully processed, due to insufficient processing time and melt temperature. A second test, incorporating operational experience from the first test, was performed and resulted in all of the 138 kg of feed material being treated. The waste simulant portion, at 41 kg, constituted 30 wt% of the total feed mass, with over 90% of this being made up of various reactive and non-reactive metals. The 95 liters of staged material was volume reduced to 41 liters, providing a 57% overall feed to product volume reduction in a fully passivated two-phase glass/metal product. The GeoMelt equipment operated as designed, vitrifying the entire batch of waste simulant. Post-melt analytical testing verified that 91-99+% of the radiological tracer metals were uniformly distributed within the glass/cast refractory/metal product, and the remaining fraction was captured in the offgas filtration systems. PCT testing of the glass and inner refractory liner showed leachability results that outperform the DOE regulatory limit of 2 g/m{sup 2} for the radiological species of interest (Sr, Ru, Cs, Eu, Re), and by more than an order of magnitude better for standard reference analytes (B, Na, Si). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Deposition Velocities of Non-Newtonian Slurries in Pipelines: Complex Simulant Testing

One of the concerns expressed by the External Flowsheet Review Team (EFRT) is about the potential for pipe plugging at the Waste Treatment and Immobilization Plant (WTP). Per the review’s executive summary, “Piping that transports slurries will plug unless it is properly designed to minimize this risk. This design approach has not been followed consistently, which will lead to frequent shutdowns due to line plugging.” To evaluate the potential for plugging, deposition-velocity tests were performed on several physical simulants to determine whether the design approach is conservative. Deposition velocity is defined as the velocity below which particles begin to deposit to form a moving bed of particles on the bottom of a straight horizontal pipe during slurry-transport operations. The deposition velocity depends on the system geometry and the physical properties of the particles and fluid. An experimental program was implemented to test the stability-map concepts presented in WTP-RPT-175 Rev. 01. Two types of simulant were tested. The first type of simulant was similar to the glass-bead simulants discussed in WTP-RPT-175 Rev. 0 ; it consists of glass beads with a nominal particle size of 150 µm in a kaolin/water slurry. The initial simulant was prepared at a target yield stress of approximately 30 Pa. The yield stress was then reduced, stepwise, via dilution or rheological modifiers, ultimately to a level of <1 Pa. At each yield-stress step, deposition-velocity testing was performed. Testing over this range of yield-stress bounds the expected rheological operating window of the WTP and allows the results to be compared to stability-map predictions for this system. The second simulant was a precipitated hydroxide that simulates HLW pretreated sludge from Hanford waste tank AZ-101. Testing was performed in a manner similar to that for the first simulant over a wide range of yield stresses; however, an additional test of net-positive suction-head required (NPSHR) was performed at each yield stress condition. Unlike the previous simulant, the sizes and densities of the particles that can deposit in the piping are a result of the simulant precipitation process; there is expected to be a complex mixture of particles of various sizes and densities that make it difficult to predict a stability map. The objective of the testing is to observe whether behavior consistent with the stability-map concept occurs in complex simulants with mixtures of different sizes and densities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Defense Waste Processing Facility (DWPF) Durability-Composition Models and the Applicability of the Associated Reduction of Constraints (ROC) Criteria for High TiO 2 Containing Glasses

Radioactive high-level waste (HLW) at the Savannah River Site (SRS) has successfully been vitrified into borosilicate glass in the DWPF since 1996. Vitrification requires stringent product/process (P/P) constraints since the glass cannot be reworked once it has been poured into ten foot tall by two foot diameter canisters. A unique “feed forward” statistical process control (SPC) was developed for this control rather than relying on statistical quality control (SQC). In SPC, the feed composition to the DWPF melter is controlled prior to vitrification. In SQC, the glass product would be sampled after it is vitrified. Individual glass property-composition models form the basis for the “feed forward” SPC. The models transform constraints on the melt and glass properties into constraints on the feed composition going to the melter in order to determine, at the 95% confidence level, that the feed will be processable and that the durability of the resulting waste form will be acceptable to a geologic repository. The DWPF SPC system is known as the Product Composition Control System (PCCS). One of the process models within PCCS is known as the Thermodynamic Hydration Energy Reaction MOdel (THERMO™). The DWPF will soon be receiving increased concentrations of TiO 2 -, Na 2 O-, and Cs 2 O-enriched wastes from the Salt Waste Processing Facility (SWPF). The SWPF has been built to pretreat the high-curie fraction of the salt waste to be removed from the HLW tanks in the F- and H-Area Tank Farms at the SRS. In order to validate the existing TiO 2 term in THERMO™ beyond 2.0 wt% in the DWPF, new durability data were developed over the target range of 2.00 to 6.00 wt% TiO 2 and evaluated against the 1995 durability model. The durability was measured by the 7-day Product Consistency Test. This study documents the adequacy of the existing THERMO™ terms. It is recommended that the modified THERMO™ durability models and the modified property acceptable region limits for the durability constraints be incorporated in the next revision of the technical bases for PCCS and then implemented into PCCS. It is also recommended that an reduction of constraints of 4 wt% Al 2 O 3 be implemented with no restrictions on the amount of alkali in the glass for TiO 2 values ≥2 wt%. The ultimate limit on the amount of TiO 2 that can be accommodated from SWPF will be determined by the three PCCS models, the waste composition of a given sludge batch, the waste loading of the sludge batch, and the frit used for vitrification.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Pu Solubility in Glass for Sludge Batch 11

Stainless-steel clad Pu from Japan’s Fast Critical Assembly (FCA) reactor is currently being dispositioned at the Savannah River Site. The electrolytic dissolver, operated by Savannah River Nuclear Solutions in H-Canyon, is being utilized to dissolve the material. The resulting solutions are transferred to the Concentration, Storage, and Transfer Facilities, operated by Savannah River Mission Completion (SRMC), for subsequent vitrification at the Defense Waste Processing Facility (DWPF). In support of the FCA mission startup, a preliminary evaluation was conducted by the Savannah River National Laboratory to assess the impact of the FCA discards on the liquid waste system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

THERMAL MODELING ANALYSIS OF CST MEDIA IN THE SMALL COLUMN ION EXCHANGE PROJECT

Models have been developed to simulate the thermal characteristics of Crystalline Silicotitanate (CST) ion exchange media fully loaded with radioactive cesium in a column configuration and distributed within a waste storage tank. This work was conducted to support the Small Column Ion Exchange (SCIX) program which is focused on processing dissolved, high-sodium salt waste for the removal of specific radionuclides (including Cs-137, Sr-90, and actinides) within a High Level Waste (HLW) storage tank at the Savannah River Site. The SCIX design includes CST columns inserted and supported in the tank top risers for cesium removal. Temperature distributions and maximum temperatures across the column were calculated with a focus on process upset conditions. A two-dimensional computational modeling approach for the in-column ion-exchange domain was taken to include conservative, bounding estimates for key parameters such that the results would provide the maximum centerline temperatures achievable under the design configurations using a feed composition known to promote high cesium loading on CST. One salt processing scenario includes the transport of the loaded (and possibly ground) CST media to the treatment tank floor. Therefore, additional thermal modeling calculations were conducted using a three-dimensional approach to evaluate temperature distributions for the entire in-tank domain including distribution of the spent CST media either as a mound or a flat layer on the tank floor. These calculations included mixtures of CST with HLW sludge or loaded Monosodium Titanate (MST) media used for strontium/actinide sorption. The current full-scale design for the CST column includes one central cooling pipe and four outer cooling tubes. Most calculations assumed that the fluid within the column was stagnant (i.e. no buoyancy-induced flow) for a conservative estimate. A primary objective of these calculations was to estimate temperature distributions across packed CST beds immersed in waste supernate or filled with dry air under various accident scenarios. Accident scenarios evaluated included loss of salt solution flow through the bed (a primary heat transfer mechanism), inadvertent column drainage, and loss of active cooling in the column. The calculation results showed that for a wet CST column with active cooling through one central and four outer tubes and 35 C ambient external air, the peak temperature for the fully-loaded column is about 63 C under the loss of fluid flow accident, which is well below the supernate boiling point. The peak temperature for the naturally-cooled (no active, engineered cooling) wet column is 156 C under fully-loaded conditions, exceeding the 130 C boiling point. Under these conditions, supernate boiling would maintain the column temperature near 130 C until all supernate was vaporized. Without active engineered cooling and assuming a dry column suspended in unventilated air at 35 C, the fully-loaded column is expected to rise to a maximum of about 258 C due to the combined loss-of coolant and column drainage accidents. The modeling results demonstrate that the baseline design using one central and four outer cooling tubes provides a highly efficient cooling mechanism for reducing the maximum column temperature. Results for the in-tank modeling calculations clearly indicate that when realistic heat transfer boundary conditions are imposed on the bottom surface of the tank wall, as much as 450 gallons of ground CST (a volume equivalent to two ion exchange processing cycles) in an ideal hemispherical shape (the most conservative geometry) can be placed in the tank without exceeding the 100 C wall temperature limit. Furthermore, in the case of an evenly-distributed flat layer, the tank wall reaches the temperature limit after the ground CST material reaches a height of approximately 8 inches.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Impact of Permanganate Oxidation of Glycolate on Corrosion of the Defense Waste Processing Facility (DWPF) Recycle Collection Tank (RCT), Transfer-line and Waste Tank Materials of Construction (MoC)

Savannah River Remediation (SRR) is evaluating the use of glycolic acid to replace formic acid as an alternate reductant for the Defense Waste Processing Facility (DWPF) at Savannah River Site (SRS). The replacement is aimed at reducing facility hazards, improving pH stability and rheological control, and lowering off gas production. Glycolate, which is the product that may remain, can also be carried downstream to High-Level Waste and Low-Level Waste facilities. Complete oxidation of glycolate and other organic species from the Sludge Receipt and Adjustment Tank (SRAT) may be necessary to minimize thermolytic hydrogen generation that can cause flammability issues. The glycolate oxidation may be performed in the Recycle Collection Tank (RCT). The RCT heel would be adjusted with sodium hydroxide to maintain the solution caustic and sodium nitrite as corrosion inhibitor prior to the addition of condensate that can be from the contents of the Slurry Mix Evaporator Condensate Tank (SMECT) or Offgas Condensate Tank (OGCT). The RCT tank collects the waste to be transferred via the Low Point Pump Pit – Recycle Pump Tank (LPPP-RPT) through a jacketed transfer-line to the Tank Farm facility. Scoping studies were performed to evaluate an oxidizing agent and sodium permanganate was selected as the best option for glycolate destruction. Testing was recommended to determine the impact on the Materials of Construction (MoC) due to the addition of sodium permanganate. The targeted concentration of sodium permanganate used equated to a 7:1 molar permanganate to glycolate ratio (nominally 0.002 M permanganate). However, to conservatively maximize the permanganate corrosivity, in some cases no glycolate was added.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Changes in cadmium mobility during composting and after soil application

The effect of twelve weeks of composting on the mobility and bioavailability of cadmium in six composts containing sewage sludge, wood chips and grass was studied, along with the cadmium immobilization capacity of compost. Two different soils were used and Cd accumulation measured in above-ground oat biomass (Avena sativa L.). Increasing pH appears to be an important cause of the observed decreases in available cadmium through the composting process. A pot experiment was performed with two different amounts of compost (9.6 and 28.8 g per kg of soil) added into Fluvisol with total Cd 0.255 mg kg{sup -1}, and contaminated Cambisol with total Cd 6.16 mg kg{sup -1}. Decrease of extractable Cd (0.01 mol l{sup -1} CaCl{sub 2}) was found in both soils after compost application. The higher amount of compost immobilized an exchangeable portion of Cd (0.11 mol l{sup -1} CH{sub 3}COOH extractable) in contaminated Cambisol unlike in light Fluvisol. The addition of a low amount of compost decreased the content of Cd in associated above-ground oat biomass grown in both soils, while a high amount of compost decreased the Cd content in oats only in the Cambisol.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A review of technologies and performances of thermal treatment systems for energy recovery from waste

Highlights: • The topic of energy recovery from waste by thermal treatment is reviewed. • Combustion, gasification and pyrolysis were considered. • Data about energy recovery performances were collected and compared. • Main limitations to high values of energy performances were illustrated. • Diffusion of energy recovery from waste in EU, USA and other countries was discussed. - Abstract: The aim of this work is to identify the current level of energy recovery through waste thermal treatment. The state of the art in energy recovery from waste was investigated, highlighting the differences for different types of thermal treatment, considering combustion/incineration, gasification and pyrolysis. Also different types of wastes – Municipal Solid Waste (MSW), Refuse Derived Fuel (RDF) or Solid Refuse Fuels (SRF) and some typologies of Industrial Waste (IW) (sludge, plastic scraps, etc.) – were included in the analysis. The investigation was carried out mainly reviewing papers, published in scientific journals and conferences, but also considering technical reports, to gather more information. In particular the goal of this review work was to synthesize studies in order to compare the values of energy conversion efficiencies measured or calculated for different types of thermal processes and different types of waste. It emerged that the dominant type of thermal treatment is incineration associated to energy recovery in a steam cycle. When waste gasification is applied, the produced syngas is generally combusted in a boiler to generate steam for energy recovery in a steam cycle. For both the possibilities – incineration or gasification – cogeneration is the mean to improve energy recovery, especially for small scale plants. In the case of only electricity production, the achievable values are strongly dependent on the plant size: for large plant size, where advanced technical solutions can be applied and sustained from an economic point of view, net electric efficiency may reach values up to 30–31%. In small-medium plants, net electric efficiency is constrained by scale effect and remains at values around 20–24%. Other types of technical solutions – gasification with syngas use in internally fired devices, pyrolysis and plasma gasification – are less common or studied at pilot or demonstrative scale and, in any case, offer at present similar or lower levels of energy efficiency.

09 BIOMASS FUELS↗

Analysis of Tank 38H (HTF-38-19-77, -78) and Tank 43H (HTF-43-19-79, -80) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. Overall, the results indicate the concentrations of most species in the Tank 38H surface and sub-surface samples increased significantly from the previous sample results. The Tank 38H sub-surface sample is more concentrated than the surface sample indicating stratification within the tank. Both the Tank 43H surface and sub-surface samples are similar in composition to the previous samples for most species analyzed. The Tank 43H subsurface sample remains slightly more concentrated than the surface sample indicating a small amount of stratification remains in the tank. The total uranium concentrations for the two Tank 38H samples differ significantly due to the presence of sludge solids in the sub-surface sample that markedly increased the uranium concentration. Both the Tank 38H surface and sub-surface samples have higher uranium concentrations than the previous samples from the tank. The weight percent water insoluble solids on the Tank 38H sub-surface sample show the sample contained 0.30 wt% insoluble solids, well below the 1 wt% limit. The total uranium concentrations of the two Tank 43H samples differ by <10% and are similar to the previous sample results. The sum of the major cations versus the sum of the major anions shows a difference of ~1% for the both the Tank 38H and Tank 43H surface samples providing an indication of good data quality for the nonradioactive analytes in the surface samples. The silicon concentrations measured in the Tank 38H surface and sub-surface samples are higher than the previous sample results. Due to the presence of sludge solids, the Tank 38H sub-surface sample show a silicon concentration an order of magnitude higher than the previous result. The Tank 43H surface and sub-surface samples have similar silicon concentrations and are similar to the previous Tank 43H samples. The silicon concentration was below detectable levels in the process blank. The five samples analyzed show silicon concentrations ranging from 88 to 710 mg/L.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

K-1435 Wastewater Treatment System for the Toxic Substances Control Act Incinerator Wastewater at the East Tennessee Technology Park, Oak Ridge, TN

This paper discusses the design and performance of a wastewater treatment system installed to support the operation of a hazardous waste incinerator. The Oak Ridge Toxic Substances Control Act Incinerator (TSCAI), located at the East Tennessee Technology Park (ETTP), is designed and permitted to treat Resource ConservatioN and Recovery Act (RCRA) wastes including characteristic and listed wastes and polychlorinated biphenyl (PCB)-contaminated mixed waste. the incinerator process generates acidic gases and particulates which consist of salts, metals, and radionuclides. These off-gases from the incinerator are treated with a wet off-gas scrubber system. The recirculated water is continuously purged (below down), resulting in a wastewater to be treated. Additional water sources are also collected on the site for treatment, including storm water that infiltrates into diked areas and fire water from the incinerator's suppression system. To meet regulatory requirements for discharge, a wastewater treatment system (WWTS) was designed, constructed, and operated to treat these water sources. The WWTS was designed to provide for periodic fluctuation of contaminant concentrations due to various feed streams to the incinverator. Blow down consists of total suspended solids (TSS) and total dissolved solids (TDS), encompassing metals, radionuclide contamination and trace organics. The system design flow rate range is 35 to 75 gallons per minute (gpm). The system is designed with redundancy to minimize time off-line and to reduce impacts to the TSCAI operations. A novel treatment system uses several unit operations, including chemical feed systems, two-stage chemical reaction treatment, microfiltration, sludge storage and dewatering, neutralization, granular activated carbon, effluent neutralization, and a complete programmable logic controller (PLC) and human-machine interface (HMI) control system. To meet the space requirements and to provide portability of the WWTS to other applications, the system was installed in three, over-the-road semi trailers, and interconnected with piping and power. Trailers were oriented on a small site footprint to facilitate ease of installation. A remote sump pump skid was provided to convey water from two holding sumps adjacent to the treatment process. An accumulation tank and pump were also provided to receive miscellaneous wastewaters for treatment if they meet the waste acceptance criteria. The paper includes details of the technology used in the design, the requirements for compliance, and the initial performance demonstration and jar testing results. The WWTS successfully allowed for highly efficient, high-volume treatment with compliant discharge to off-site surface water.

54 ENVIRONMENTAL SCIENCES↗

Functional Insights of Salinity Stress-Related Pathways in Metagenome-Resolved Methanothrix Genomes

Recently, methanogenic archaea belonging to the genus Methanothrix were reported to have a fundamental role in maintaining stable ecosystem functioning in anaerobic bioreactors under different configurations/conditions. In this study, we reconstructed three Methanothrix metagenome-assembled genomes (MAGs) from granular sludge collected from saline upflow anaerobic sludge blanket (UASB) reactors, where Methanothrix harundinacea was previously implicated with the formation of compact and stable granules under elevated salinity levels (up to 20 g/L Na + ). Genome annotation and pathway analysis of the Methanothrix MAGs revealed a genetic repertoire supporting their growth under high salinity. Specifically, the most dominant Methanothrix (MAG_279), classified as a subspecies of Methanothrix_A harundinacea_D, had the potential to augment its salinity resistance through the production of different glycoconjugates via the N-glycosylation process, and via the production of compatible solutes as N ε -acetyl-β-lysine and ectoine. The stabilization and reinforcement of the cell membrane via the production of isoprenoids was identified as an additional stress-related pathway in this microorganism. The improved understanding of the salinity stress-related mechanisms of M. harundinacea highlights its ecological niche in extreme conditions, opening new perspectives for high-efficiency methanisation of organic waste at high salinities, as well as the possible persistence of this methanogen in highly-saline natural anaerobic environments.

59 BASIC BIOLOGICAL SCIENCES↗

An Assessment of the Materials of Construction for the Transfer Lines and Unit Operations Equipment Associated with the Recycle Diversion Process

The Defense Waste Processing Facility (DWPF) processes and vitrifies radioactive waste that it receives from the Concentration, Storage, and Transfer Facility (CSTF) and Salt Waste Processing Facility (SWPF). As a result of the evaporation of water during both the melter feed preparation and the melter feed vitrification steps in DWPF, a recycle waste stream is generated, neutralized, and sent back to the CSTF. The recycle waste is a dilute water stream originating from the collection of condensate liquids containing some minor sludge and frit solids and other waste components primarily resulting from entrainment into the condensate during foam-over events. The recycle stream volume is significant and is expected to approach 3 million gallons per year once the SWPF reaches full operation. Diverting the bulk of the recycle waste stream from the CSTF is essential for the eventual closure of the waste tanks, and hence the completion of the SRS liquid waste mission.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improving Volatile Fatty Acid Productivity of Anaerobic Digestion

Typical anaerobic digestion (AD) focusses on complete conversion of waste to biogas (primarily carbon dioxide and methane). However, the intermediate metabolites of the AD process, which includes short- and long-chain volatile fatty acids (VFAs), that could serve as the precursors for useful industrial applications are typically ignored. The goal of this project is to eliminate production of biogas while enhancing the production of the intermediate VFAs. Using a mixed microbial consortium (from rumen sources and waste-water sludge), we have determined the optimal carbon loading (chemical oxygen demand, "COD") and optimal pH, that results in high VFA concentrations from food waste. The best VFA yields were obtained using 15 g COD/L and a pH of 9.0 for this substrate. pH 9 produced over 200% higher VFA titers than the controlled conditions (i.e., ph 7.0) after 35 d of digestion, in comparison to pH 5 that showed - 88% higher titers than the control digestion. As expected, the cumulative biogas production was highest in the pH 7.0 condition, in comparison to pH 5.0 or pH 9.0. We further observed that removal of VFAs using solid-liquid separation technique reduce the inhibitory effects of VFAs, thereby leading to overall improvement in conversion efficiency. 16s rRNA analysis is being carried out to explain and identify the biocatalysts that enable VFA production in these AD cultures. Additional efforts to improve VFA yields via increasing the total solid content, temperature optimizations, VFA removal via electrodialysis, and improving hydrolysis via microaeration will be presented.

anaerobic digestion↗

CHANGING THE SAFETY CULTURE IN HANFORD TANK FARMS

In 2000 the Hanford Tank Farms had one of the worst safety records in the Department of Energy Complex. By the end of FY08 the safety performance of the workforce had turned completely around, resulting in one of the best safety records in the DOE complex for operations of its kind. This paper describes the variety of programs and changes that were put in place to accomplish such a dramatic turn-around. The U.S. Department of Energy's 586-square-mile Hanford Site in Washington State was established during World War II as part of the Manhattan Project to develop nuclear materials to end the war. For the next several decades it continued to produce plutonium for the nation's defense, leaving behind vast quantities of radioactive and chemical waste. Much of this waste, 53,000,000 gallons, remains stored in 149 aging single-shell tanks and 28 newer double-shell tanks. One of the primary objectives at Hanford is to safely manage this waste until it can be prepared for disposal, but this has not always been easy. These giant underground tanks, many of which date back to the beginning of the Manhattan Project, range in size from 55,000 gallons up to 1.1 million gallons, and are buried beneath 10 feet of soil near the center of the site. Up to 67 of the older single-shell tanks have leaked as much as one million gallons into the surrounding soil. Liquids from the single-shell tanks were removed by 2003 but solids remain in the form of saltcake, sludges and a hardened heel at the bottom of some tanks. The Department of Energy's Office of River Protection was established to safely manage this waste until it could be prepared for disposal. For most of the last seven years the focus has been on safely retrieving waste from the 149 aging single-shell and moving it to the newer double-shell tanks. Removing waste from the tanks is a difficult and complex task. The tanks were made to put waste in, not take it out. Because of the toxic nature of the waste, both chemically as well as radiologically, all retrieval operations must be performed using remote-controlled equipment which has to be installed in each tank, then removed when retrieval is completed. This process involves a variety of potentially hazardous construction activities including crane and rigging, excavation, electrical and piping work. It also requires strong attention to safety to avoid injuries to personnel and contamination of the environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PROTEC TM TEAR-OFFS: RESULTS OF LONG TERM TESTING

The Savannah River National Laboratory (SRNL) has completed a series of tests (Phases 1 and 2) to assess the potential use of a Mylar{reg_sign} tear-off system as a primary or secondary protective barrier to minimize acid etching ('frosting'), accidental scratching, and/or radiation damage for shielded cells, glovebox, and/or chemical hood windows. Conceptually, thin, multi-layered sheets of Mylar (referred to throughout this report as the ProTec{trademark} tear-off system) can be directly applied to the shielded cell, glovebox, or hood sash window to serve as a secondary (or primary) barrier. Upon degradation of visual clarity due to accidental scratching, spills/splatters, and/or radiation damage, the outer layer (or sheet) of Mylar could be removed refreshing or restoring the view. Due to the multilayer aspect, the remaining Mylar layers would provide continued protection for the window from potential reoccurrences. Although the concept of using a tear-off system as a protective barrier is conceptually enticing, potential technical issues were identified and addressed as part of this phased study to support implementation of this type of system in the Defense Waste Processing Facility (DWPF). Specific test conditions of interest to the DWPF included the performance of the tear-off system exposed to or under the following conditions: (1) acid(s) (concentrated (28.9 M) HF, concentrated (15.9M) HNO{sub 3}, 6M HCl, and 0.6M H{sub 3}BO{sub 3}); (2) base (based on handling of radioactive sludges with pH of {approx}12-13); (3) gamma radiation (due to radioactive sources or materials being used in the analytical cells); (4) scratch resistance (simulating accidental scratching with the manipulators); and (5) in-situ testing (sample coupons exposed to actual field conditions in DWPF). The results of the Phase 1 study indicated that the ProTec tear-off concept (as a primary or secondary protective barrier) is a potential technical solution to prevent or retard excessive damage that would result from acid etching, base damage (as a result of a sludge spill or splatter), gamma radiation damage, and/or accidental scratching (due to manipulator/tool contact). Although identified as a potential solution, the Phase 1 testing was relatively short-term with exposure times up to 1-2 months for the acid and gamma radiation tests. Phase 2 testing included longer exposure times for the acid resistance (up to 456 days) and gamma radiation exposure (700 days with a cumulative gamma dose of {approx}3.1 x 10{sup 5} rad) assessments. The tear-off system continued to perform well in these longer-term acid resistance testing and gamma exposure conditions. Complete removal of the tear-offs after these long-term exposure times indicate that not only could visual clarity be restored but the mechanical integrity could be retained. The results also provided insight into the ability of the ProTec tear-off system to withstand the chemical and physical abuses expected in off-normal shielded cells operations. The conceptual erasing of scratches or marks by excessive manipulator abuse was demonstrated in the SRNL Shielded Cells mock-up facility through the removal of the outer layer tear-off with manipulators. In addition, the Phase 2 testing included an in-situ assessment of a prototype tear-off system in the DWPF Sampling Cells where the system was exposed to actual field conditions including radioactive sources, acidic and basic environments, dusting, and chemical cleaning solutions over a 5-6 month period. DWPF personnel were extremely satisfied with the performance (including the successful removal of 3 layers with manipulators) of the ProTec tear-off system under actual field conditions. The successful removal of the outer layer tear-offs with the manipulator, using tabs not specifically designed for remote operations, demonstrates that the system is 'manipulator-friendly' and could be implemented in a remote environment. The ability to remove the outer layer tear-off not only regains visual clarity but also reduces waste disposal volumes (i.e., disposal of a thin sheet of Mylar which is 'collapsible' versus the bulk disposal of a rigid Lexan{reg_sign} sheet (alpha shield) or glovebox/sash window) which is more cost effective. The tear-off system could also reduce the number of cell entries needed to replace the Lexan sheet and increase the time interval between glovebox/sash window replacements, which can be costly and time consuming. Although the primary focus of this study addresses the application of the ProTec tear-off system to shielded cells windows, the concept is also potentially applicable to glovebox and hood sash windows. In fact, the tear-off concept is potentially applicable to any system where visual clarity is compromised given the environmental conditions of the test. In addition, the tear-offs could be applied to walls or shelves where a protective barrier would reduce deterioration or discoloration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Remote Evaporator Vessel Repair by Robotics and Powder Injection Laser Welding - 18107

In February 2016 a leak was identified in the 25H evaporator at the Savannah River Site (SRS). The 25H evaporator is used to manage water volume in high level waste (HLW) tanks during solid salt cake and sludge removal. The location and the cause of the leak were unknown. Orano Federal Services (formerly AREVA Federal Services) applied its robotics expertise and commercial nuclear expertise to perform the inspection. Orano and Framatome (formerly AREVA NP INC) combined a BROKK, a commonly used tracked vehicle with remote control, with the KUKA, an automated robotic arm, commonly used in automobile manufacturing, to perform the partial dismantlement and inspection. Once inspection was complete and the leak was identified, Orano conducted a study on two welding processes: Gas Tungsten Arc (GTA-Tig) and Powder Injection Laser Welding. Based on the inspection of the SRS HLW evaporator's material type being Hastelloy{sup R}, along with the remote repair and material thin wall condition, the Powder Injection Laser Welding was chosen for this application. Orano has developed the remote powder injection laser welding and delivery process that will be used to conduct the repair of the SRS HLW evaporator in the fall of 2017. The process includes robotic delivery of components and robotic performance of the weld. Specialized robotic equipment were developed or adapted from other industries to perform the high hazard job of repairing an eroded section of the evaporator pot. The integration of multiple innovative remote techniques provides a unique solution in a highly radioactive environment. These techniques and innovations can be capitalized upon to solve many different remote repairs on equipment resulting in time savings, reduced dose to personnel, and recovery of initial investment in equipment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗