Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Chirped-grating spectrometer-on-a-chip

We demonstrate an on-chip spectrometer readily integrable with CMOS electronics. The structure is comprised of a SiO 2 /Si 3 N 4 /SiO 2 waveguide atop a silicon substrate. A transversely chirped grating is fabricated, in a single-step optical lithography process, on a portion of the waveguide to provide angle and wavelength dependent coupling to the guided mode. The spectral and angular information is encoded in the spatial dependence of the grating period. A uniform pitch grating area, separated from the collection area by an unpatterned propagation region, provides the out-coupling to a CMOS detector array. A resolution of 0.3 nm at 633 nm with a spectral coverage tunable across the visible and NIR (to ∼ 1 µm limited by the Si photodetector) by changing the angle of incidence, is demonstrated without the need for any signal processing deconvolution. This on-chip spectrometer concept will cost effectively enable a broad range of applications that are beyond the reach of current integrated spectroscopic technologies.

Nezhadbadeh, Shima↗

Single photon detection and timing in the Lunar Laser Ranging Experiment.

The goals of the Lunar Laser Ranging Experiment lead to the need for the measurement of a 2.5 sec time interval to an accuracy of a nanosecond or better. The systems analysis which included practical retroreflector arrays, available laser systems, and large telescopes led to the necessity of single photon detection. Operation under all background illumination conditions required auxiliary range gates and extremely narrow spectral and spatial filters in addition to the effective gate provided by the time resolution. Nanosecond timing precision at relatively high detection efficiency was obtained using the RCA C31000F photomultiplier and Ortec 270 constant fraction of pulse-height timing discriminator. The timing accuracy over the 2.5 sec interval was obtained using a digital interval with analog vernier ends. Both precision and accuracy are currently checked internally using a triggerable, nanosecond light pulser. Future measurements using sub-nanosecond laser pulses will be limited by the time resolution of single photon detectors.

Poultney, S. K.↗

A multisatellite case study of the expansion of a substorm current wedge in the near-earth magnetotail

Results are presented on observations from four satellites (GOES 5, GOES 6, AMPTE CCE, and AMPTE IRM) and two ground stations (San Juan and Tucson) on a substorm that occurred on April 19, 1985 at about 0830 UT. The four spacecraft were arrayed in a configuration that made it possible to separate the effects arising from the longitudinal versus the radial expansion of the substorm current wedge and thus to examine its spatial evolution. The sequence of events that was observed suggests that, during this substorm, the disruption of the cross-tail current sheet, the formation of the substorm current wedge, and the expansion of the plasma sheet began in the near-earth region, and subsequently spread tailward as well as longitudinally.

Lopez, R. E.↗

Radio observations of D I and fractionation

We report observations to detect the 327 MHz line of atomic deuterium in the primarily molecular clouds towards Cas A and Sgr A, making appropriate choices of spectral and spatial resolution. Our best results for Cas A, based on 1253 hr of observing with the 85 foot (26 m) Hat Creek telescope and 45 hr with the very large array (VLA), yield an upper limit for the fraction of deuterium in atomic form, D I, of 0.14. We present an approximate analytical analysis of deuterium fractionation in translucent clouds, which shows that gas-phase ion-molecule reactions, assisted by dust and HD line self-shielding, are efficient in converting deuterium to HD. We conclude that little atomic deuterium is present in the molecular clumps in the Cas A clouds and that much higher sensitivity observations would be required to detect 327 MHz line in molecular clouds. We have also attempted to detect the 72 GHz line of DCO(+) toward Cas A. The observed upper limit to the DCO(+)/HCO(+) ratio of approximately 0.03 is not much larger than our theoretical estimate, and the DCO(+) line should be detectable with existing instrumentation, unless the temperature of these clouds is much larger than usually assumed.

Heiles, Carl↗

Cassini CIRS Observations of Saturn's Rings

In the spring of 2004, during Cassini s approach to Saturn, the Cassini Composite Infrared Spectrometer (CIRS) began acquiring thermal spectra of Saturn s rings. CIRS is a Fourier-transform spectrometer that measures radiation in the thermal infrared from 7 microns to 1 millimeter (1400 to 10/cm). CIRS has a set of 21 detectors, consisting of two 1 x 10 linear arrays with a pixel size of 0.3 mrad, and one 4 mrad circular detector. Just after the completion of the Saturn orbit insertion (SOI) burn, CIRS performed an especially high spatial resolution scan of portions of Saturn s A, B and C rings. In the months following SOI, additional ring measurements have been obtained, including radial scans on the lit and unlit sides of the rings, and azimuthal scans across the shadowed regions of the A, B and C rings.

Spilker, Linda J.↗

STAR Concept for Passive Microwave Temperature Sounding from Middle Earth Orbit (MeoSTAR)

A future mission for a new microwave atmospheric temperature sounder radiometer in a Middle Earth Orbit (MEO) at 11,000 km altitude is described. The MeoSTAR design uses a stationary l-dimensional Synthetic Thinned Array Radiometer in the 50-60 GHz microwave sounding band, to provide a 'pushbroom' image as the satellite orbits. The advantage of this concept is an image with a high spatial resolution and a wide swath with no scanning antenna to disturb the visual and IR sensors on the same satellite.

microwave radiometers↗

CMOS foveal image sensor chip

A foveal image sensor integrated circuit comprising a plurality of CMOS active pixel sensors arranged both within and about a central fovea region of the chip. The pixels in the central fovea region have a smaller size than the pixels arranged in peripheral rings about the central region. A new photocharge normalization scheme and associated circuitry normalizes the output signals from the different size pixels in the array. The pixels are assembled into a multi-resolution rectilinear foveal image sensor chip using a novel access scheme to reduce the number of analog RAM cells needed. Localized spatial resolution declines monotonically with offset from the imager's optical axis, analogous to biological foveal vision.

Bandera, Cesar↗

Acoustic diagnostic system and method for superconducting devices operating in gas or liquid

A novel system and method for detecting a quench of a superconducting conductor and detecting abnormal behavior of a superconducting conductor using acoustic sensor technology in the coolant of a superconducting cable and/or magnet is disclosed. This system and method is not only limited to use for superconductors, but also may be used for any device disposed in liquid and gas. Acoustic sensors are installed along a coolant space of a superconducting conductor and monitor coolant conditions. By monitoring acoustic changes, temperature changes or coolant flow disruption can be detected very quickly by an acoustic sensor array. By disposition of the acoustic sensor array in a coolant flow channel, the acoustic sensor system can quickly detect a local condition, such as the thermal status (temperature) of a superconducting cable and magnet with precise spatial resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spatially resolved molecular gas properties of host galaxy of Type I superluminous supernova SN 2017egm

Abstract We present the results of CO(1–0) observations of the host galaxy of a Type I superluminous supernova (SLSN-I), SN 2017egm, one of the closest SLSNe-I at z = 0.03063, by using the Atacama Large Millimeter/submillimeter Array. The molecular gas mass of the host galaxy is Mgas = (4.8 ± 0.3) × 109 M⊙, placing it on the sequence of normal star-forming galaxies in an Mgas–star-formation rate (SFR) plane. The molecular hydrogen column density at the location of SN 2017egm is higher than that of the Type II SN PTF10bgl, which is also located in the same host galaxy, and those of other Type II and Ia SNe located in different galaxies, suggesting that SLSNe-I have a preference for a dense molecular gas environment. On the other hand, the column density at the location of SN 2017egm is comparable to those of Type Ibc SNe. The surface densities of molecular gas and the SFR at the location of SN 2017egm are consistent with those of spatially resolved local star-forming galaxies and follow the Schmidt–Kennicutt relation. These facts suggest that SLSNe-I can occur in environments with the same star-formation mechanism as in normal star-forming galaxies.

Hatsukade, Bunyo (ORCID:0000000164698725)↗

The Hurricane Imaging Radiometer (HIRAD): Instrument Status and Performance Predictions

The Hurricane Imaging Radiometer (HIRAD) is an innovative radiometer which offers new and unique remotely sensed observations of both extreme oceanic wind events and strong precipitation. It is based on the airborne Stepped Frequency Microwave Radiometer (SFMR) [Uhlhorn and Black, 2004]. The HIRAD instrument advances beyond the current nadir viewing SFMR to an equivalent wide-swath SFMR imager using passive microwave synthetic thinned aperture radiometer (STAR) technology [Ruf et al., 1988]. This sensor operates over 4-7 GHz, where the required tropical cyclone remote sensing physics has been validated by both SFMR and WindSat radiometer [Bettenhausen et al., 2006; Brown et al., 2006]. HIRAD incorporates a new and unique array antenna design along with several technologies successfully demonstrated by the Lightweight Rain Radiometer instrument [Ruf et al., 2002; Ruf and Principe, 2003]. HIRAD will be a compact, lightweight, low-power instrument with no moving parts that will produce wide-swath imagery of ocean winds and rain in hurricane conditions. Accurate observations of surface ocean vector winds (OVW) with high spatial and temporal resolution are required for understanding and predicting tropical cyclones. The Hurricane Imaging Radiometer (HIRAD) is an innovative architecture which offers new and unique remotely sensed observations of both extreme oceanic wind events and strong precipitation. It is based on the airborne Stepped Frequency Microwave Radiometer (SFMR), which is a proven remote sensing technique for observing tropical cyclone (TC) ocean surface wind speeds and rain rates. The proposed HIRAD instrument advances beyond the current nadir viewing SFMR to an equivalent wide-swath SFMR imager using passive microwave synthetic thinned aperture radiometer (STAR) technology combined with a a unique array antenna design. The overarching design concept of HIRAD is to combine the multi-frequency C-band observing strategy of the SFMR with STAR technology to produce a wide-swath imager. Single frequency STAR technology The Hurricane Imaging Radiometer (HIRAD) is an innovative radiometer which offers new and unique remotely sensed observations of both extreme oceanic wind events and strong precipitation. It is based on the airborne Stepped Frequency Microwave Radiometer (SFMR) [Uhlhorn and Black, 2004]. The HIRAD instrument advances beyond the current nadir viewing SFMR to an equivalent wide-swath SFMR imager using passive microwave synthetic thinned aperture radiometer (STAR) technology [Ruf et al., 1988]. This sensor operates over 4-7 GHz, where the required tropical cyclone remote sensing physics has been validated by both SFMR and WindSat radiometer [Bettenhausen et al., 2006; Brown et al., 2006]. HIRAD incorporates a new and unique array antenna design along with several technologies successfully demonstrated by the Lightweight Rain Radiometer instrument [Ruf et al., 2002; Ruf and Principe, 2003]. HIRAD will be a compact, lightweight, low-power instrument with no moving parts that will produce wide-swath imagery of ocean winds and rain in hurricane conditions. Accurate observations of surface ocean vector winds (OVW) with high spatial and temporal resolution are required for understanding and predicting tropical cyclones. The Hurricane Imaging Radiometer (HIRAD) is an innovative architecture which offers new and unique remotely sensed observations of both extreme oceanic wind events and strong precipitation. It is based on the airborne Stepped Frequency Microwave Radiometer (SFMR), which is a proven remote sensing technique for observing tropical cyclone (TC) ocean surface wind speeds and rain rates. The proposed HIRAD instrument advances beyond the current nadir viewing SFMR to an equivalent wide-swath SFMR imager using passive microwave synthetic thinned aperture radiometer (STAR) technology combined with a a unique array antenna design. The overarching design concept of HIRAD is to combine the multi-frequency C-banbserving strategy of the SFMR with STAR technology to produce a wide-swath imager. Single frequency STAR technology

Ruf, Christopher↗

System implications of large radiometric array antennas

Current radiometric earth and atmospheric sensing systems in the centimeter wavelength range generally employ a directive antenna connected through a single terminal pair to a Dicke receiver. It is shown that this approach does not lend itself to systems with greatly increased spatial resolution. Signal to noise considerations relating to antenna efficiency force the introduction of active elements at the subarray level; thus, if Dicke switching is to be used, it must be distributed throughout the system. Some possible approaches are suggested. The introduction of active elements at the subarray level is found to ease the design constraints on time delay elements, necessary for bandwidth, and on multiple beam generation, required in order to achieve sufficient integration time with high resolution.

Levis, C. A.↗

Super-Resolution Ptychography with Small Segmented Detectors

To overcome the spatial resolution limit set by aperture-limited diffraction in traditional scanning transmission electron microscopy, microscopists have developed ptychography enabled by iterative phase retrieval algorithms and high-dynamic-range pixel array detectors. Current detector designs are limited by the data rate off chip, so a high-pixel-count detector has a proportionally lower frame rate than the few-segment detectors used for differential phase contrast (DPC) imaging. This slower acquisition speed leads to heightened vulnerability to scan noise, drift, and potential sample damage. This creates opportunities for repurposing fast segmented detectors for ptychography by trading a reduction in reciprocal space pixels for an increase in real space pixels. Here, we explore a strategy of oversampling in real space and instead apply detector pixel upsampling during the reconstruction process. Further, we demonstrate the viability of achieving super-resolution ptychography on thin objects using only 2 × 2 detector pixels, surpassing the resolution of integrated DPC (iDPC) imaging. With optimization using simulated datasets and experiments on MoTe 2 /WSe 2 bilayer moiré superlattices, we achieved super-resolution ptychography reconstructions under rapid acquisition conditions (37.5 pA, 1 μs dwell time), yielding over 50% improvements in contrast and information limit compared to annular dark field and iDPC imaging on the same detectors.

2D materials↗

Binary pseudo-random array (BPRA) for inspection and calibration for cylindrical wavefront interferometry

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. However, surface topography measurements are instrument dependent, and without the knowledge of how the instrument performs under the practical usage conditions, the measured data contain some degree of uncertainty. Binary Pseudo Random Array (BPRA) “white noise” artifact are effective and useful for characterizing the Instrument Transfer Function (ITF) of surface topography metrology tools and wavefront measurement instrument. BPRA artifact contains features with all spatial frequencies in the instrument bandpass with equal weight. As a result, power spectral density of the patterns has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range. The application examples include electron microscopes, x-ray microscopes, interferometric microscopes, and large field-of-view Fizeau Interferometers. Furthermore, we will introduce the application of BPRA method to characterizing the ITF of Cylindrical Wavefront Interferometry (CWI), by developing the BPRA artifact which matches the radius of curvature of the cylindrical wavefront. The data acquisition and analysis procedures for different applications of the ITF calibration technique developed are also discussed.

Munechika, K↗

A high resolution soil moisture radiometer

The design of an L-band high resolution soil moisture radiometer is described. The selected system is a planar slotted waveguide array at L-band frequencies. The square aperture is 74.75 m by 74.75 m subdivided into 8 tilted subarrays. The system has a 290 km circular orbit and provides a spatial resolution of 1 km. The aperture forms 230 simultaneous beams in a cross-track pattern which covers a swath 420 km wide. A revisit time of 6 days is provided for an orbit inclination of 50 deg. The 1 km resolution cell allows an integration time of 1/7 second and sharing this time period sequentially between two orthogonal polarization modes can provide a temperature resolution of 0.7 K.

Dod, L. R.↗

Geographic science team

The rational for using remote sensing in land use/land cover, geomorphology, and cartography applications is stated as well as potential uses in each of these areas. The next step to be perfected is indicated. Spatial and spectral resolution requirements for photointerpretations and/or multispectral pattern recognition of geomorphic elements and of cultural surface cover are listed. Requirements for photographic/analog or digital photogrammetry from spaceborne multispectral linear array sensors are included. A prioritized summary of data gaps in the geographic sciences is included.

Bryant, N.↗

Speckle spectroscopy; an application for the multi-anode microchannel array detector system

Plans to combine the High Angular Resolution Imager/Spectrometer on the 4-meter Mayall telescope at the Kitt Peak National Observatory and the (256 x 1024)-pixel Multi-Anode Microchannel Array detector system to produce a unique instrument for speckle spectroscopy are described. The pulse-counting detector system will provide distortion-free imaging and will time tag each spatially-resolved photon event with an accuracy of 100 ns. The Imager/Spectrometer will provide a spatial resolution of 0.07 arcsec orthogonal to the plane of dispersion and 0.18 arcsec in the plane of dispersion.

Butcher, H. R.↗

Thermal response of large area high temperature superconducting YBaCuO infrared bolometer

Thermal analysis of large area high temperature superconducting infrared detector operating in the equilibrium mode (bolometer) was performed. An expression for the temperature coefficient beta=1/R(dR/dT) in terms of the thermal conductance and the thermal time constant of the detector were derived. A superconducting transition edge bolometer is a thermistor consisting of a thin film superconducting YBaCuO evaporated into a suitable thermally isolated substrate. The operating temperature of the bolometer is maintained close to the midpoint of the superconducting transition region where the resistance R has a maximum dynamic range. A detector with a strip configuration was analyzed and an expression for the temperature rise (delta T) above the ambient due to a uniform illumination with a source of power density P(sub i) was calculated. An expression for the thermal responsivity of the detector was derived using the thermal diffusion analysis with appropriate boundary conditions. It was found that the thermal responsibility depends upon the spatial modulation frequency and the angular frequency of the incoming radiation. The problem of the thermal cross talk between different detector elements was addressed. In the case of monolithic HTS detector array with a row of square elements of dimensions 2a and CCD or CID readout electronics the thermal spread function was derived for different spacing between elements. This analysis can be critical for future design and applications of large area focal plane arrays as broad band optical detectors made of granular thin films HTS YBaCuO.

Khalil, Ali E.↗