Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

A strainmeter array as the fulcrum of novel observatory sites along the Alto Tiberina Near Fault Observatory

Fault slip is a complex natural phenomenon involving multiple spatiotemporal scales from seconds to days to weeks. To understand the physical and chemical processes responsible for the full fault slip spectrum, a multidisciplinary approach is highly recommended. The Near Fault Observatories (NFOs) aim at providing high-precision and spatiotemporally dense multidisciplinary near-fault data, enabling the generation of new original observations and innovative scientific products. The Alto Tiberina Near Fault Observatory is a permanent monitoring infrastructure established around the Alto Tiberina fault (ATF), a 60 km long low-angle normal fault (mean dip 20°), located along a sector of the Northern Apennines (central Italy) undergoing an extension at a rate of about 3 mm yr –1 . The presence of repeating earthquakes on the ATF and a steep gradient in crustal velocities measured across the ATF by GNSS stations suggest large and deep (5–12 km) portions of the ATF undergoing aseismic creep. Both laboratory and theoretical studies indicate that any given patch of a fault can creep, nucleate slow earthquakes, and host large earthquakes, as also documented in nature for certain ruptures (e.g., Iquique in 2014, Tōhoku in 2011, and Parkfield in 2004). Nonetheless, how a fault patch switches from one mode of slip to another, as well as the interaction between creep, slow slip, and regular earthquakes, is still poorly documented by near-field observation. With the strainmeter array along the Alto Tiberina fault system (STAR) project, we build a series of six geophysical observatory sites consisting of 80–160 m deep vertical boreholes instrumented with strainmeters and seismometers as well as meteorological and GNSS antennas and additional seismometers at the surface. By covering the portions of the ATF that exhibits repeated earthquakes at shallow depth (above 4 km) with these new observatory sites, we aim to collect unique open-access data to answer fundamental questions about the relationship between creep, slow slip, dynamic earthquake rupture, and tectonic faulting.

58 GEOSCIENCES↗

Primary Water Stress Corrosion Cracks in Nickel Alloy Dissimilar Metal Welds: Detection and Sizing Using Established and Emerging Nondestructive Examination Techniques

The U.S. Nuclear Regulatory Commission has established the Program to Assess the Reliability of Emerging Nondestructive Techniques (PARENT) as a follow-on to the international cooperative Program for the Inspection of Nickel Alloy Components (PINC). The goal of PINC was to evaluate the capabilities of various nondestructive evaluation (NDE) techniques to detect and characterize surface-breaking primary water stress corrosion cracks in dissimilar-metal welds (DMW) in bottom-mounted instrumentation (BMI) penetrations and small-bore (≈400-mm diameter) piping components. A series of international blind round-robin tests were conducted by commercial and university inspection teams. Results from these tests showed that a combination of conventional and phased-array ultrasound techniques provided the highest performance for flaw detection and depth sizing in dissimilar metal piping welds. The effective detection of flaws in BMIs by eddy current and ultrasound shows that it may be possible to reliably inspect these components in the field. The goal of PARENT is to continue the work begun in PINC and apply the lessons learned to a series of open and blind international round-robin tests that will be conducted on a new set of piping components including large-bore (≈900-mm diameter) DMWs, small-bore DMWs, and BMIs. Open round-robin testing will engage universities and industry worldwide to investigate the reliability of emerging NDE techniques to detect and accurately size flaws having a wide range of lengths, depths, orientations, and locations. Blind round-robin testing will invite testing organizations worldwide, whose inspectors and procedures are certified by the standards for the nuclear industry in their respective countries, to investigate the ability of established NDE techniques to detect and size flaws whose characteristics range from easy to very difficult to detect and size. This paper presents highlights of PINC and reports on the plans and progress for PARENT round-robin tests.

cracks↗

Characterization of a Low-Cost Multiparameter Sensor for Solar Resource Applications

Low-cost, multiparameter sensing and measurement devices enable cost-effective monitoring of the functional, operational reliability, efficiency, and resiliency of the electric grid. The National Renewable Research Laboratory (NREL) Solar Radiation Research Laboratory (SRRL), in collaboration with Arable Labs, Inc., deployed Arable Lab's Mark multiparameter sensor system. The device measures the downwelling and upwelling shortwave solar resource and longwave radiation, humidity, air temperature, and ground temperature. The system is also equipped with six downward-and upward-facing narrowband spectrometer channels that measure spectral radiation and surface spectral reflectance. This study describes the shortwave calibration, characterization, and validation of measurement accuracy of this instrument by comparison with existing instruments that are part of NREL-SRRL's Baseline Measurement System.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a cell culture surface conversion technique using alginate thin film for evaluating effect upon cellular differentiation

Here, we sought to develop a cell culture surface conversion technique that would not damage living cells. An alginate thin film, formed on a glass plate by spin coating of sodium alginate solution and dipping into calcium chloride solution, was used to inhibit adhesion of cells. The film could be removed by ethylenediaminetetraacetate (EDTA) at any time during cell culture, permitting observation of cellular responses to conversion of the culture surface in real time. Additionally, we demonstrated the validity of the alginate thin film coating method and the performance of the film. The thickness of the alginate thin film was controlled by varying the rotation speed during spin coating. Moreover, the alginate thin film completely inhibited the adhesion of cultured cells to the culture surface, irrespective of the thickness of the film. When the alginate thin film was removed from the culture surface by EDTA, the cultured cells adhered to the culture surface, and their morphology changed. Finally, we achieved effective differentiation of C2C12 myoblasts into myotube cells by cell culture on the convertible culture surface, demonstrating the utility of our novel technique.

36 MATERIALS SCIENCE↗

Observable signature of a background deviating from the Kerr metric

By detecting gravitational wave signals from extreme mass ratio inspiraling sources (EMRIs) we will be given the opportunity to check our theoretical expectations regarding the nature of supermassive bodies that inhabit the central regions of galaxies. We have explored some qualitatively new features that a perturbed Kerr metric induces in its geodesic orbits. Since a generic perturbed Kerr metric does not possess all the special symmetries of a Kerr metric, the geodesic equations in the former case are described by a slightly nonintegrable Hamiltonian system. According to the Poincare-Birkhoff theorem, this causes the appearance of the so-called Birkhoff chains of islands on the corresponding surfaces of section in between the anticipated KAM curves of the integrable Kerr case, whenever the intrinsic frequencies of the system are at resonance. The chains of islands are characterized by finite width, i.e. there is a finite range of initial conditions that correspond to a particular resonance and consequently to a constant rational ratio of intrinsic frequencies. Thus while the EMRI changes adiabatically by radiating energy and angular momentum, by monitoring the frequencies of a signal we can look for a transient pattern, in the form of a plateau, in the evolution of their ratio. We have shown that such a plateau is anticipated to be apparent in a quite large fraction of possible orbital characteristics if the central gravitating source is not a Kerr black hole. Moreover, the plateau in the ratio of frequencies is expected to be more prominent at specific rational values that correspond to the strongest resonances. This gives a possible observational detection of such non-Kerr exotic objects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monitoring Surface Phenomena Created by an Underground Chemical Explosion Using Fully Polarimetric VideoSAR

Sandia National Laboratories flew its Facility for Advanced RF and Algorithm Development X-Band (9.6-GHz center frequency), fully polarimetric synthetic aperture radar (PolSAR) in VideoSAR mode to collect complex-valued SAR imagery before, during, and after the sixth Source Physics Experiment's (SPE-6) underground explosion. The VideoSAR products generated from the data sets include "movies'' of single- and quad-polarization coherence maps, magnitude imagery, and polarimetric decompositions. Residual defocus, due to platform motion during data acquisition, was corrected with a digital elevation model-based autofocus algorithm. We generated and exploited the VideoSAR image products to characterize the surface movement effects caused by the underground explosion. Unlike seismic sensors, which measure local area seismic waves using sparse spacing and subterranean positioning, these VideoSAR products captured high-spatial resolution, 2-D, time-varying surface movement. The results from the fifth SPE (SPE-5) used single-polarimetric VideoSAR data. In this paper, we present single-polarimetric and fully polarimetric VideoSAR results while monitoring the SPE-6 underground chemical explosion. We show that fully polarimetric VideoSAR imaging provides a unique, coherent, time-varying measure of the surface expression of the SPE-6 underground chemical explosion. As a result, we include new surface characterization results from the measured PolSAR SPE-6 data via H/A/α polarimetric decomposition.

47 OTHER INSTRUMENTATION↗

Comparing Coarse-Resolution Land Surface Temperature Products over Western Australia

Satellite-derived land surface temperature (LST) has commonly been used to monitor global temperature changes. The MODIS MYD11A2 product is the most common coarse-resolution product used for this purpose. An updated MODIS product (MYD21A2) and new VIIRS (VNP21A2) product have also recently become available. This study analyses eight-day, quality-controlled, LST imagery over Western Australia (WA) for the three products for an urban and a non-urban area for the years 2013, 2016, and 2019. An analysis of the data indicates that (i) the averaged daytime LST difference between the three products for Perth city over the three years was 1.32 °C, while at night it was 0.89 °C; (ii) the averaged daytime difference over the Kimberley region was 7.02 °C with a night average difference of 2.39 °C; and (iii) both the MYD21A2 and VNP21A2 products still appear to record anomalous monthly LST values, particularly in the humid Kimberley monsoonal months. The overall objective of the National Aeronautics and Space Administration (NASA) is to ensure that the LST values of the two satellite system products are comparable, so evidence of LST value differences will require further investigation, especially if the older product is to be replaced by the newer systems.

47 OTHER INSTRUMENTATION↗

Confocal Raman Microscopy as a Probe of Material Deconstruction in Processed Low-Density Polyethylene Particles

Confocal Raman microscopy was applied to detect structural change within individual particles of low-density polyethylene (LDPE) following chemical and electrochemical processing steps that aimed to facilitate material decomposition. A high numerical aperture (NA) oil-immersion objective enabled depth-profiling through the near surface region (20 μm–40 μm) of irregularly shaped particles with an axial spatial resolution < 2 μm estimated from measurements of instrument detection efficiency profiles. Changes in vibrational bands sensitive to polyethylene crystallinity were evident following treatments and linked to the release of low molecular weight compounds present as additives and products of processing. Effects of processing were probed by monitoring the rise of Raman scattering intensity in vibrational modes associated with polyethylene chains in a zig-zag (trans) conformation near 1128 cm –1 , 1294 cm –1 , and 1418 cm –1 , signaling chain clustering and development of organized, crystalline-like assemblies. Pristine LDPE particles displayed a uniform structure across the near surface region, while particles treated initially with chemical extractant and then further processed displayed increasingly enhanced crystallinity up to the maximum depth probed (40 μm). As a step toward measurements on ensembles of particles, least squares modeling was adapted to derive pure component spectra reflecting crystallinity change within spectral datasets. The work demonstrates high spatial resolution Raman depth-profiling for the characterization of processed polymers using a high NA immersion objective to overcome the limitations of air-objectives often used for confocal Raman microscopy.

Wahiduzzaman, Md. [Department of Chemistry and Bio↗

Note: A novel technique for analysis of aqueous solutions by laser-induced breakdown spectroscopy

Surface-enhanced Raman spectroscopy (SERS) substrates typically consist of gold or silver nanoparticles deposited on a non-conductive substrate. In Raman spectroscopy, the nanoparticles produce an enhancement of the electromagnetic field which, in turn, leads to greater electronic excitation of molecules in the local environment. Here, we show that these same surfaces can be used to enhance the signal-to-noise ratio obtained in laser-induced breakdown spectroscopy of aqueous solutions. In this case, the SERS substrates not only lower breakdown thresholds and lead to more efficient plasma initiation but also provide an appropriately wettable surface for the deposition of the liquid. We refer to this technique as surface-enhanced laser-induced breakdown spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of PuO 2 With Visible and UV Raman Spectroscopy: Discrimination Between the Bulk, Surface, and an Intermediate Disordered Layer

Raman spectroscopy is an ideal tool in the characterization of materials including PuO 2 . The wavelength-dependent absorptivity of the material defines the light penetration depth and the relative Raman scattering contribution from the bulk and the surface. Here, the surface contribution to the total Raman scattering was investigated for PuO 2 calcined at various temperatures and recorded with laser wavelengths of 355, 325, and 244 nm. These experiments provided the first glimpse of the wavelength-dependent disappearance and emergence of new phonons and electronic bands from the PuO 2 surface layers. The first indication of the wavelength transition in the Raman spectra was the loss of the 2LO2 (overtone, ~1155 cm -1 ) band and the weakening intensity of the Г 1 → Γ 5 electronic band (~2135 cm -1 ) with the 355-nm excitation laser. The Γ 5 electronic band was barely visible with the 244-nm excitation. The electronic band located at ~1050 cm -1 , corresponding to the Г 1 → Γ 4 electronic transition was observed to dramatically increase in intensity while the Г 1 → Γ 3 electronic band (2640 cm -1 ) sharpened as the UV wavelength was increased in energy from the near- to deep-UV (355–325–244 nm). The FWHM of the T 2g band was found to vary with calcination temperature (450°C and 900°C) with the 325-nm laser and the 244-nm laser. The T 2g band attributes, the strong emergence of the Г 1 → Γ 4 electronic band, and the disappearance of the 2LO2 overtone acquired with the 244-nm excitation for the different calcination temperatures suggest a shallow penetration depth.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge management for gravitational-wave observatories using UV LEDs

Accumulation of electrical charge on the end mirrors of gravitational-wave observatories can become a source of noise limiting the sensitivity of such detectors through electronic couplings to nearby surfaces. Torsion balances provide an ideal means for testing gravitational-wave technologies due to their high sensitivity to small forces. Our torsion pendulum apparatus consists of a movable plate brought near a plate pendulum suspended from a nonconducting quartz fiber. A UV LED located near the pendulum photoejects electrons from the surface, and a UV LED driven electron gun directs photoelectrons towards the pendulum surface. We have demonstrated both charging and discharging of the pendulum with equivalent charging rates of {approx}10{sup 5}e/s, as well as spectral measurements of the pendulum charge resulting in a white noise level equivalent to 3x10{sup 5}e/{radical}(Hz).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cleaned 5-Minute Resolution Air Quality and Meteorological Data from Nine TCEQ CAMS Sites in Houston, Texas (Nov 2021 – Oct 2022)

These data encompass 5-minute air monitoring and meteorological observations collected in the greater Houston, Texas metropolitan region, at nine (9) Continuous Ambient Monitoring Stations (CAMS) operated by the Texas Commission on Environmental Quality (TCEQ) between November 1, 2021 and October 31, 2022. The CAMS sites (CAMS 1, 8, 35, 45, 148, 403, 405, 410, and 1052) were chosen because their instrumentation includes measurements of PM2.5. These sites also provide continuous multi-parameter air-quality and meteorological measurements. Particulate matter (PM2.5, PM10) was sampled along with several trace gases, including ozone (O3), nitrogen oxides (NO, NO2, NOx), sulfur dioxide (SO2), and carbon monoxide (CO). The data set also contains standard surface meteorological parameters (temperature, humidity, pressure, wind speed, and wind direction). Several sites also include AutoGC-based measurements of volatile organic compounds (VOCs). Air monitoring instruments deployed at the selected sites comprise the following systems: BAM-1020 or TEOM (PM2.5), Thermo Scientific TEI 49i (O3), TEI 42i (NOx), and AutoGCs (VOCs). This data set is similar to the data included within the houairq5mX1.00 datastream, except for a few additional quality control steps. A systematic data cleaning and verification process was performed on the data set to ensure its quality and preparation for analysis. Removal of non-numeric status flags (e.g., [LIM], [QAS], [SPZ], [CAL], [PMA], [AQI], [SPN], [MAL]) was accomplished by employing rule-based string parsing to extract valid numerical values. Missing entries were set to -9999; however, invalid or anomalous values (e.g., 99999) were retained as originally reported by the TCEQ to preserve data provenance. The time sequence was verified for completeness, removal of duplicates, and uniformity at 5-minute intervals. Column labeling was standardized, and corresponding values were assessed for physical plausibility. All timestamps in the data set were reported in Coordinated Universal Time (UTC) as provided by the TCEQ. Further, the latitude and longitude coordinates were added for each CAMS site. A subset of the data (June 1–September 30, 2022) has been used in the following publication: Subba et al. 2025. “Implications of sea breeze circulations on boundary layer aerosols in the southern coastal Texas region.” EGUsphere 2025: 1–49, https://doi.org/10.5194/egusphere-2025-2659.

latitude↗

Optimal alignment of mirror based pentaprisms for scanning deflectometric devices

In the recent work [Proc. of SPIE 7801, 7801-2/1-12 (2010), Opt. Eng. 50(5) (2011), in press], we have reported on improvement of the Developmental Long Trace Profiler (DLTP), a slope measuring profiler available at the Advanced Light Source Optical Metrology Laboratory, achieved by replacing the bulk pentaprism with a mirror based pentaprism (MBPP). An original experimental procedure for optimal mutual alignment of the MBPP mirrors has been suggested and verified with numerical ray tracing simulations. It has been experimentally shown that the optimally aligned MBPP allows the elimination of systematic errors introduced by inhomogeneity of the optical material and fabrication imperfections of the bulk pentaprism. In the present article, we provide the analytical derivation and verification of easily executed optimal alignment algorithms for two different designs of mirror based pentaprisms. We also provide an analytical description for the mechanism for reduction of the systematic errors introduced by a typical high quality bulk pentaprism. It is also shown that residual misalignments of an MBPP introduce entirely negligible systematic errors in surface slope measurements with scanning deflectometric devices.

47 OTHER INSTRUMENTATION↗

Investigation on Growth and Surface Analysis of DAST Single Crystals

We have explored the growth of bulk size N, N-dimethylamino-N'-methylstilbazolium p-toluenesulphonate (DAST) using slope nucleation method. The grown crystal was characterized by single crystal X-ray diffraction (XRD), and CHN analyses. The surface morphology of the crystal was analyzed using Scanning electron microscopy (SEM).

36 MATERIALS SCIENCE↗

Momentum resolution in inverse photoemission

We present a method to determine the electron beam divergence, and thus the momentum resolution, of an inverse-photoemission setup directly from a series of spectra measured on Cu(111). Simulating these spectra with different beam divergences shows a distinct influence of the divergence on the appearance of the Shockley surface state. Upon crossing the Fermi level, its rise in intensity can be directly linked with the beam divergence. A comparison of measurement and simulation enables us to quantify the momentum resolution independent of surface quality, energy resolution, and experimental geometry. With spin resolution, a single spectrum taken around the Fermi momentum of a spin-split surface state, e.g., on Au(111), is sufficient to derive the momentum resolution of an inverse-photoemission setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigations of protons passing through the CR-39/PM-355 type of solid state nuclear track detectors

Solid State Nuclear Track Detectors of the CR-39/PM-355 type were irradiated with protons with energies in the range from 0.2 to 8.5 MeV. Their intensities and energies were controlled by a Si surface barrier detector located in an accelerator scattering chamber. The ranges of protons with energies of 6–7 MeV were comparable to the thickness of the PM-355 track detectors. Latent tracks in the polymeric detectors were chemically etched under standard conditions to develop the tracks. Standard optical microscope and scanning electron microscopy techniques were used for surface morphology characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron Strippers for Compact Neutron Generators

The next generation of compact tandem-type DD or DT neutron generators requires a robust electron stripper with high charge exchange efficiency. In this study, stripping foils of various types were tested, and the H{sup -} to H{sup +} conversion efficiency, endurance to the heat load, and durability were investigated in terms of suitability in the tandem-type neutron generator. In the experiments, a H{sup -} beam was accelerated to about 180 keV, passes through a stripping foil, and produces a mixed beam of H{sup -}, H{sup 0}, and H{sup +}. These ions were separated by an electric field, and detected by a movable Faraday cup to determine the conversion efficiency. The experimental results using thin foils of diamond-like carbon, gold, and carbon nano-tubes revealed issues on the robustness. As a new concept, a H{sup -} beam was injected onto a metal surface with an oblique angle, and reflected H{sup +} ions are detected. It was found that the conversion efficiency, H{sup +} fraction in the reflected particles, depends on the surface condition, with the maximum value of about 90%.

43 PARTICLE ACCELERATORS↗

Efficiency analysis of helium-cooled MAS DNP: case studies of surface-modified nanoparticles and homogeneous small-molecule solutions

Despite the growing number of successful applications of dynamic nuclear polarization (DNP)-enhanced magic-angle spinning (MAS) NMR in structural biology and materials science, the nuclear polarizations achieved by current MAS DNP instrumentation are still considerably lower than the theoretical maximum. Here, the method could be significantly strengthened if experiments were performed at temperatures much lower than those currently widely used (~100 K). Recently, the prospects of helium (He)-cooled MAS DNP have been increased with the instrumental developments in MAS technology that uses cold helium gas for sample cooling. Despite the additional gains in sensitivity that have been observed with He-cooled MAS DNP, the performance of the technique has not been evaluated in the case of surfaces and interfaces that benefit the most from DNP. Herein, we studied the efficiency of DNP at temperatures between ~30 K and ~100 K for organically functionalized silica material and a homogeneous solution of small organic molecules at a magnetic field B 0 = 16.4 T. We recorded the changes in signal enhancement, paramagnet-induced quenching and depolarization effects, DNP build-up rate, and Boltzmann polarization. For these samples, the increases in MAS-induced depolarization and DNP build-up times at around 30 K were not as severe as anticipated. In the case of the surface species, we determined that MAS DNP at 30 K provided ~10 times higher sensitivity than MAS DNP at 90 K, which corresponds to the acceleration of experiments by multiplicative factors of up to 100.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗