Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Collagen esterification enhances the function and survival of pancreatic β cells in 2D and 3D culture systems

Collagen, one of the most important components of the extracellular matrix (ECM), may play a role in the survival of pancreatic islet cells. In addition, chemical modifications that change the collagen charge profile to a net positive charge by esterification have been shown to increase the adhesion and proliferation of various cell types. The purpose of this study was to characterize and compare the effects of native collagen (NC) and esterified collagen (EC) on β cell function and survival. After isolation by the collagenase digestion technique, rat islets were cultured with NC and EC in 2 dimensional (2D) and 3 dimensional (3D) environments for a long-term duration in vitro. The cells were assessed for islet adhesion, morphology, viability, glucose-induced insulin secretion, and mRNA expression of glucose metabolism-related genes, and visualized by scanning electron microscopy (SEM). Islet cells attached tightly in the NC group, but islet cell viability was similar in both the NC and EC groups. Glucose-stimulated insulin secretion was higher in the EC group than in the NC group in both 2D and 3D culture. Furthermore, the mRNA expression levels of glucokinase in the EC group were higher than those in the NC group and were associated with glucose metabolism and insulin secretion. Finally, SEM observation confirmed that islets had more intact component cells on EC sponges than on NC sponges. These results indicate that modification of collagen may offer opportunities to improve function and viability of islet cells. - Highlights: • We changed the collagen charge profile to a net positive charge by esterification. • Islets cultured on esterified collagen improved survival in both 2D and 3D culture. • Islets cultured on esterified collagen enhanced glucose-stimulated insulin release. • High levels of glucokinase mRNA may be associated with increased insulin release.

60 APPLIED LIFE SCIENCES↗

Energy Coupling Mechanisms and Scaling Behavior Associated with Laser Powder Bed Fusion Additive Manufacturing

In situ optical absorptivity measurements are carried out to clarify the physics of the laser-material interactions involved and to validate both finite element and analytical models describing laser powder bed fusion processing. Absorption of laser energy is evaluated directly using precise calorimetry measurements and compared to melt pool depths for common structural metal alloys (Ti-6Al-4V, Inconel 625, and stainless steel 316L) as a function of incident laser power, scan velocity and laser beam diameter. Changes in both absorptivity and melt pool depths for all materials are found to vary strongly across the conduction-keyhole mode threshold. A hydrodynamic finite element model is coupled to a ray-tracing-based absorptivity model, yielding excellent agreement with the experimental results and elucidating additional physics. The experimental results are further analyzed using normalized enthalpy ( β ) and normalized thermal diffusion length ( L* th ) relations and demonstrate that the normalized melt pool depth ( d* = d/a , where d is melt pool depth and a is beam radius) is proportional to βL* th , while absorptivity follows an asymptotic exponential function against βL* th . Expressions for melt pool depth and laser absorptivity across different materials and laser scan systems are derived and thus provide useful tools to accelerate the optimization of laser processing parameters for metal 3D printing processes.

36 MATERIALS SCIENCE↗

Cost and Time Effective Lithography of Reusable Millimeter Size Bone Tissue Replicas With Sub‐15 nm Feature Size on A Biocompatible Polymer

Abstract The ability to replicate the microenvironment of biological tissues creates unique biomedical possibilities for stem cell applications. Current fabrication methods are limited by either the control on feature size and shape, or by the throughput and size of the replicas. Here, a novel platform is reported that combines thermal scanning probe lithography (tSPL) with innovative methodologies for the low‐cost and high‐throughput nanofabrication of large area quasi‐3D bone tissue replicas with high fidelity, sub‐15 nm lateral precision, and sub‐2 nm vertical resolution. This bio‐tSPL platform features a biocompatible polymer resist that withstands multiple cell culture cycles, allowing the reuse of the replicas, further decreasing costs and fabrication times. The as‐fabricated replicas support the culture and proliferation of human induced mesenchymal stem cells, which display broad therapeutic and biomedical potential. Furthermore, it is demonstrated that bio‐tSPL can be used to nanopattern the bone tissue replicas with amine groups, for subsequent tissue‐mimetic biofunctionalization. The achieved level of time and cost‐effectiveness, as well as the cell compatibility of the replicas, make bio‐tSPL a promising platform for the production of tissue‐mimetic replicas to study stem cell‐tissue microenvironment interactions, test drugs, and ultimately harness the regenerative capacity of stem cells and tissues for biomedical applications.

Liu, Xiangyu↗

Opening band gaps of low-dimensional materials at the meta-GGA level of density functional approximations

The quasiparticle band structure can be properly described by Hedin's GW approximation (GW), at a high computational cost. For band gaps, semilocal density functionals up to the generalized gradient approximation (GGA) level cannot compete with the accuracy of hybrid-based approximations or GW. Meta-GGA density functionals with a strong dependence on the kinetic energy density ingredient can potentially give wider band gaps compared with GGAs. The recent TASK meta-GGA density functional from Aschebrock and Kümmel [ Phys. Rev. Research 1 , 033082 (2019) ], is constructed with an enhanced nonlocality in the generalized Kohn-Sham scheme and therefore harbors great opportunities for band gap prediction. Although this approximation was found to yield excellent band gaps of bulk solids, this accuracy cannot be straightforwardly transferred to low-dimensional materials. Additionally, the reduced screening of these materials results in larger band gaps compared with their bulk counterparts, as an additional barrier to overcome. In this paper we demonstrate how the alteration of this functional affects the band gaps of monolayers and nanoribbons and present accurate band gaps competing with the revised Heyd-Scuseria-Ernzerhof (HSE06) approximation. In order to achieve this goal, we have modified the TASK functional (a) by changing the tight upper bound for one- or two-electron systems ( h X 0 ) from 1.174 to 1.29 and (b) by changing the limit of the interpolation function f X ( α → ∞ ) of the TASK functional that interpolates the exchange enhancement factor F X ( s , α ) from α = 0 to 1. The resulting modified TASK (mTASK) was tested for various materials from three dimensions to two dimensions to one dimension (nanoribbons) and was compared with the results of the higher-level hybrid functional HSE06 or with the G 0 W 0 approximation within many-body perturbation theory. We find that mTASK systematically improves the band gaps and band structures of two-dimensional (2D) and 1D systems, without significantly affecting the accuracy of the original TASK for the bulk 3D materials, when compared with the Perdew-Burke-Ernzerhof (PBE) GGA and the strongly constrained and appropriately normed (SCAN) meta-GGA. We further demonstrate the applicability of mTASK by assessing the band structures of transition metal dichalcogenide nanoribbons with respect to various bending curvatures.

36 MATERIALS SCIENCE↗

Evaluation of a multi-atlas based method for segmentation of cardiac CTA data: a large-scale, multicenter, and multivendor study

Purpose: Computed tomography angiography (CTA) is increasingly used for the diagnosis of coronary artery disease (CAD). However, CTA is not commonly used for the assessment of ventricular and atrial function, although functional information extracted from CTA data is expected to improve the diagnostic value of the examination. In clinical practice, the extraction of ventricular and atrial functional information, such as stroke volume and ejection fraction, requires accurate delineation of cardiac chambers. In this paper, we investigated the accuracy and robustness of cardiac chamber delineation using a multiatlas based segmentation method on multicenter and multivendor CTA data. Methods: A fully automatic multiatlas based method for segmenting the whole heart (i.e., the outer surface of the pericardium) and cardiac chambers from CTA data is presented and evaluated. In the segmentation approach, eight atlas images are registered to a new patient's CTA scan. The eight corresponding manually labeled images are then propagated and combined using a per voxel majority voting procedure, to obtain a cardiac segmentation. Results: The method was evaluated on a multicenter/multivendor database, consisting of (1) a set of 1380 Siemens scans from 795 patients and (2) a set of 60 multivendor scans (Siemens, Philips, and GE) from different patients, acquired in six different institutions worldwide. A leave-one-out 3D quantitative validation was carried out on the eight atlas images; we obtained a mean surface-to-surface error of 0.94{+-}1.12 mm and an average Dice coefficient of 0.93 was achieved. A 2D quantitative evaluation was performed on the 60 multivendor data sets. Here, we observed a mean surface-to-surface error of 1.26{+-}1.25 mm and an average Dice coefficient of 0.91 was achieved. In addition to this quantitative evaluation, a large-scale 2D and 3D qualitative evaluation was performed on 1380 and 140 images, respectively. Experts evaluated that 49% of the 1380 images were very accurately segmented (below 1 mm error) and that 29% were accurately segmented (error between 1 and 3 mm), which demonstrates the robustness of the presented method. Conclusions: A fully automatic method for whole heart and cardiac chamber segmentation was presented and evaluated using multicenter/multivendor CTA data. The accuracy and robustness of the method were demonstrated by successfully applying the method to 1420 multicenter/multivendor data sets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-230: Evaluation of ViewRay 0.35 T MRI Normal Structure Segmentation

Purpose: In order to take advantage of the high resolution soft tissue imaging available in MR images, we investigated 3D images obtained with the low field 0.35 T MR in ViewRay to serve as an alternative to CT scans for radiotherapy treatment planning. In these images, normal and target structure delineation can be visualized. Assessment is based upon comparison with the CT images and the ability to produce comparable contours. Methods: Routine radiation oncology CT scans were acquired on five patients. Contours of brain, brainstem, esophagus, heart, lungs, spinal cord, and the external body were drawn. The same five patients were then scanned on the ViewRay TrueFISP-based imaging pulse sequence. The same organs were selected on the MR images and compared to those from the CT scan. Physical volume and the Dice Similarity Coefficient (DSC) were used to assess the contours from the two systems. Image quality stability was quantitatively ensured throughout the study following the recommendations of the ACR MR accreditation procedure. Results: The highest DSC of 0.985, 0.863, and 0.843 were observed for brain, lungs, and heart respectively. On the other hand, the brainstem, spinal cord, and esophagus had the lowest DSC. Volume agreement was most satisfied for the heart (within 5%) and the brain (within 2%). Contour volume for the brainstem and lung (a widely dynamic organ) varied the most (27% and 19%). Conclusion: The DSC and volume measurements suggest that the results obtained from ViewRay images are quantitatively consistent and comparable to those obtained from CT scans for the brain, heart, and lungs. MR images from ViewRay are well-suited for treatment planning and for adaptive MRI-guided radiotherapy. The physical data from 0.35 T MR imaging is consistent with our geometrical understanding of normal structures.

60 APPLIED LIFE SCIENCES↗

SU-E-T-500: Initial Implementation of GPU-Based Particle Swarm Optimization for 4D IMRT Planning in Lung SBRT

Purpose 4D-IMRT planning, combined with dynamic MLC tracking delivery, utilizes the temporal dimension as an additional degree of freedom to achieve improved OAR-sparing. The computational complexity for such optimization increases exponentially with increase in dimensionality. In order to accomplish this task in a clinically-feasible time frame, we present an initial implementation of GPU-based 4D-IMRT planning based on particle swarm optimization (PSO). Methods The target and normal structures were manually contoured on ten phases of a 4DCT scan of a NSCLC patient with a 54cm3 right-lower-lobe tumor (1.5cm motion). Corresponding ten 3D-IMRT plans were created in the Eclipse treatment planning system (Ver-13.6). A vendor-provided scripting interface was used to export 3D-dose matrices corresponding to each control point (10 phases × 9 beams × 166 control points = 14,940), which served as input to PSO. The optimization task was to iteratively adjust the weights of each control point and scale the corresponding dose matrices. In order to handle the large amount of data in GPU memory, dose matrices were sparsified and placed in contiguous memory blocks with the 14,940 weight-variables. PSO was implemented on CPU (dual-Xeon, 3.1GHz) and GPU (dual-K20 Tesla, 2496 cores, 3.52Tflops, each) platforms. NiftyReg, an open-source deformable image registration package, was used to calculate the summed dose. Results The 4D-PSO plan yielded PTV coverage comparable to the clinical ITV-based plan and significantly higher OAR-sparing, as follows: lung Dmean=33%; lung V20=27%; spinal cord Dmax=26%; esophagus Dmax=42%; heart Dmax=0%; heart Dmean=47%. The GPU-PSO processing time for 14940 variables and 7 PSO-particles was 41% that of CPU-PSO (199 vs. 488 minutes). Conclusion Truly 4D-IMRT planning can yield significant OAR dose-sparing while preserving PTV coverage. The corresponding optimization problem is large-scale, non-convex and computationally rigorous. Our initial results indicate that GPU-based PSO with further software optimization can make such planning clinically feasible. This work was supported through funding from the National Institutes of Health and Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Elemental and topographical imaging of microscopic variations in deposition on NSTX-U and DIII-D samples

Tokamak plasma facing components have surface roughness that can cause microscopic spatial variations in erosion and deposition and hence influence material migration, erosion lifetime, dust and tritium accumulation, and plasma contamination. However high spatial resolution measurements of deposition on the scale of the surface roughness have been lacking to date. We will present elemental images of graphite samples from NSTX-U and DIII-D DiMES experiments performed with a Scanning Auger Microprobe at sub-micron resolution that show strong microscopic variations in deposition and correlate this with 3D topographical maps of surface irregularities. The NSTX-U samples were boronized and exposed to deuterium plasmas and the DiMES samples had localized Al and W films and were exposed to dedicated helium plasmas. Topographical maps of the samples were performed with a 3D confocal optical microscope and compared to the elemental deposition pattern. The results revealed localized deposition concentrated in areas shadowed from the ion flux, incident in a direction calculated (for the DiMES case) by taking account of the magnetic pre-sheath.

Surface analysis↗

Elemental and topographical imaging of microscopic variations in deposition on NSTX-U and DIII-D samples2

Abstract: Tokamak plasma facing components have surface roughness that can cause microscopic spatial variations in erosion and deposition and hence influence material migration, erosion lifetime, dust and tritium accumulation, and plasma contamination. However high spatial resolution measurements of deposition on the scale of the surface roughness have been lacking to date. We will present elemental images of graphite samples from NSTX-U and DIII-D DiMES experiments performed with a Scanning Auger Microprobe at sub-micron resolution that show strong microscopic variations in deposition and correlate this with 3D topographical maps of surface irregularities. The NSTX-U samples were boronized and exposed to deuterium plasmas and the DiMES samples had localized Al and W films and were exposed to dedicated helium plasmas. Topographical maps of the samples were performed with a 3D confocal optical microscope and compared to the elemental deposition pattern. The results revealed localized deposition concentrated in areas shadowed from the ion flux, incident in a direction calculated (for the DiMES case) by taking account of the magnetic pre-sheath.

Erosion, Deposition, NSTX-U, DIMES, Plasma-Materia↗

Additive Manufacturing of Sensors and Components for Non-Destructive Evaluation Applications

Additively manufactured machine components were designed for use in non-destructive evaluations. Additive manufacturing (3D printing) enables rapid production of simple or complex objects at a low cost for use in many fields of research and industry. 3D printed components were used to optimize an eddy current array probe to inspect various complex shaped objects, such as gears. Preliminary eddy current inspections were conducted to test the functionality and compatibility of the 3D printed components to the array probe and existing system. These were done by wrapping replica 3D printed gears with aluminum foil. The results were as expected, rough, uneven surface of the aluminum foil. Calibration scans were also executed to enable proper measurement of defect size in metal structures. For use in waveguide-based distributive sensing technologies, additively manufactured custom waveguides were designed for use in liquid environments to collect pressure and flow data. Waveguides were designed with membranes, thin sections of the walls, which would be pressed inward due to fluid pressure. Waveguide models continue to be developed and revised for most functional utility in liquid environments.

36 MATERIALS SCIENCE↗

An All-Fiber, Modular, Compact Wind Lidar for Wind Sensing and Wake Vortex Applications

This paper discusses an innovative, compact and eyesafe coherent lidar system developed for wind and wake vortex sensing applications. With an innovative all-fiber and modular transceiver architecture, the wind lidar system has reduced size, weight and power requirements, and provides enhanced performance along with operational elegance. This all-fiber architecture is developed around fiber seed laser coupled to uniquely configured fiber amplifier modules. The innovative features of this lidar system, besides its all fiber architecture, include pulsewidth agility and user programmable 3D hemispherical scanner unit. Operating at a wavelength of 1.5457 microns and with a PRF of up to 20 KHz, the lidar transmitter system is designed as a Class 1 system with dimensions of 30"(W) x 46"(L) x 60"(H). With an operational range exceeding 10 km, the wind lidar is configured to measure wind velocities of greater than 120 m/s with an accuracy of +/- 0.2 m/s and allow range resolution of less than 15 m. The dynamical configuration capability of transmitted pulsewidths from 50 ns to 400 ns allows high resolution wake vortex measurements. The scanner uses innovative liquid metal slip ring and is built using 3D printer technology with light weight nylon. As such, it provides continuous 360 degree azimuth and 180 degree elevation scan angles with an incremental motion of 0.001 degree. The lidar system is air cooled and requires 110 V for its operation. This compact and modular lidar system is anticipated to provide mobility, reliability, and ease of field deployment for wind and wake vortex measurements. Currently, this wind lidar is undergoing validation tests under various atmospheric conditions. Preliminary results of these field measurements of wind characteristics that were recently carried out in Colorado are discussed.

Prasad, Narasimha S.↗

Preserving, Enhancing, and Continuing the Scientific Legacy of the Apollo Sample Suite

From 1969 to 1972, Apollo astronauts collected 382 kg of rocks, soils, and core samples from six geologically diverse locations on the Moon. In the nearly 50 years since the samples were collected, over 3000 different studies have been conducted using the nearly 2200 different Apollo samples. Despite the maturity of the sample collection, many new studies of lunar samples are undertaken each year, with an average of more than 55 requests and more than 600 distinct subsamples allocated annually over the past five years. The Apollo samples are a finite resource, however. Although new studies are encouraged, it is important that new studies do not duplicate previous studies, and where possible, leverage previous results to inform and enhance the current studies. This helps to preserve the samples and scientific funding, both of which are precious resources. We have initiated several new efforts to rescue some of the early analyses from these samples, including unpublished analytical data. We are actively scanning NASA documentation in paper form that is related to the Apollo missions and sample processing, and we are collaborating with IEDA to establish a geochemical data base called MoonDB. To populate this database, we are actively working with about a dozen prominent lunar PIs to organize and transcribe years of both published and unpublished data, making it available to all researchers. This effort will also take advantage of new online analytical tools like PetDB. There have already been tangible results from the MoonDB data rescue effort. A pilot project involving the rescue of geochemical data of John Delano on Apollo pyroclastic glasses has already been referenced in multiple Apollo sample requests, and in fact, the compiled data was used as part of one of the new studies. Similarly, scanned sample handling reports have been utilized to find previously analyzed samples that were appropriate to fulfill new sample requests. We have also begun to image the Apollo samples using (1) micro‐CT scanning to document the interior structure of samples, and (2) comprehensive high resolution photography of samples, enabling high resolution 3D reconstructions of the samples. Both efforts will provide comprehensive access to these samples and allow for more targeted requests, and thus better curation of the samples for decades to come.

Zeigler, Ryan↗

Advancement of Deep Learning and Geometric Methods for Active Terrain Relative Navigation

To enhance NASA’s precision landing capabilities, in conjunction with the development of a novel active terrain relative navigation (ATRN) and terrain mapping system, denoted SHERIF, this work performed a comparative analysis between both deep-learning (DL) based and geometric approaches to hazard detection (HD) and safe-site-identification (SSI) through hardware-in-the loop testing on the Six degree-of-freedom Tendon Actuated Robot (STAR). The Standalone Hazard Evaluation and Refinement using Instrument Findings (SHERIF) system is capable of ingesting sensor data at an asynchronous rate, stitching successive terrain scans together to yield a high-resolution digital elevation map (DEM), performing absolute and relative localization using novel 3D feature extraction and matching methods, and HD/SSI activities. The DL-based HD/SSI algorithm provides a modular alternative to classical geometric approaches which have performance times that scale with map resolution. As the adoption of AI solutions become more prevalent for autonomous system decision making, it is prudent to explore the utility of such solutions in applications where they traditionally excel, such as image classification. Along with the development of a DL-based HD system, this work performed the first comparative analysis between DL and geometric approaches to HD/SSI using real sensor data from real-time testing in a relevant environment.

Davis Adams↗

Simurgh: A Framework for Cad-Driven Deep Learning Based X-Ray CT Reconstruction

High-resolution X-ray computed tomography (XCT) is an important technique for the inspection of additively manufactured (AM) parts. While XCT is typically used off-line to inspect a subset of manufactured parts, significantly accelerating measurement speed while retaining accuracy would enable use of XCT for in-line inspection to rapidly identify defects in each part as it is manufactured. Here, we propose a deep learning (DL) based approach that uses computer aided design (CAD) models of the AM parts and physics-based information to rapidly produce high-quality reconstructions from sparse XCT measurements without high quality ground truth data. Our approach uses a generative adversarial neural network (GAN) to produced realistic training data from the CAD-based simulations and a deep neural network that is trained using data from the first stage to produce accurate 3D reconstructions. Using experimental XCT data of metal parts, we demonstrate enhanced defect detection capabilities while dramatically reducing the scan time.

Ziabari, Amir↗

Development of a lab-scale, high-resolution, tube-generated X-ray computed-tomography system for three-dimensional (3D) materials characterization

The design and construction of a modular high resolution X-ray computed tomography (XCT) system is highlighted in this paper. The design approach is detailed for meeting a specified set of instrument performance goals tailored towards experimental versatility and high resolution imaging. The XCT tool is unique in the detector and X-ray source design configuration, enabling control in the balance between detection efficiency and spatial resolution. The system package is also unique: The sample manipulation approach implemented enables a wide gamut of in situ experimentation to analyze structure evolution under applied stimulus, by optimizing scan conditions through a high degree of controllability. The component selection and design process is detailed: Incorporated components are specified, custom designs are shared, and the approach for their integration into a fully functional XCT scanner is provided. Custom designs discussed include the dual-target X-ray source cradle which maintains position and trajectory of the beam between the two X-ray target configurations with respect to a scintillator mounting and positioning assembly and the imaging sensor, as well as a novel large-format X-ray detector with enhanced adaptability. The instrument is discussed from an operational point of view, including the details of data acquisition and processing implemented for 3D imaging via micro-CT. The performance of the instrument is demonstrated on a silica-glass particle/hydroxyl-terminated-polybutadiene (HTPB) matrix binder PBX simulant. Post-scan data processing, specifically segmentation of the sample's relevant microstructure from the 3D reconstruction, is provided to demonstrate the utility of the instrument. - Highlights: • Custom built X-ray tomography system for microstructural characterization • Detector design for maximizing polychromatic X-ray detection efficiency • X-ray design offered for maximizing X-ray flux with respect to imaging resolution • Novel lab-scale XCT data acquisition and data processing methods • 3D characterization of glass-bead mock plastic-bonded-explosive stimulant.

36 MATERIALS SCIENCE↗

LANL Robotic Vessel Scanning

Los Alamos National Laboratory in J-1 DARHT Operations Group uses 6ft spherical vessels to contain hazardous materials produced in a hydrodynamic experiment. These contaminated vessels must be analyzed by means of a worker entering the vessel to locate, measure, and document every penetration mark on the vessel. If the worker can be replaced by a highly automated robotic system with a high precision scanner, it will eliminate the risks to the worker and provide management with an accurate 3D model of the vessel presenting the existing damage with the flexibility to manipulate the model for better and more in-depth assessment.The project was successful in meeting the primary goal of installing an automated system which scanned a 6ft vessel with an elapsed time of 45 minutes. This robotic system reduces the total time for the original scope of work by 75 minutes and results in excellent data accumulation and transmission to the 3D model imaging program.

Computer Hardware↗

Three-dimensional nanostructures on Ge/Si(100) wetting layers: Hillocks and pre-quantum dots

The annealing of sub-critical Ge wetting layers (WL < 3.5 ML) initiates the formation of 3D nanostructures, whose shape and orientation is determined by the WL thickness and thus directly related to the strain energy. The emergence of these nanostructures, hillocks and pre-quantum dots, is studied by scanning tunneling microscopy. A wetting layer deposited at 350 °C is initially rough on the nanometer length-scale and undergoes a progressive transformation and smoothening during annealing at T < 460 °C when vacancy lines and the 2xn reconstruction are observed. The metastable Ge WL then collapses to form 3D nanostructures whose morphology is controlled by the WL thickness: first, the hillocks, with a wedding cake-type structure where the step edges run parallel to the 〈110〉 direction, are formed from thin wetting layers, while {105}-faceted structures, called pre-quantum dots (p-QDs), are formed from thicker layers. The wetting layer thickness and thus the misfit strain energy controls the type of structure. The crossover thickness between the hillock and p-QDs regime is between 1.6 and 2.1 ML. The hillocks have larger lateral dimensions and volumes than p-QDs, and the p-QDs are exceptionally small quantum dots with a lower limit of 10 nm in width. Our work opens a new pathway to the control of nanostructure morphology and size in the elastically strained Ge/Si system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗