Search NASA⌕ Search

SEARCH · Search NASA

Results for “ADHESION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Load-deflection tests and computer analyses of a high-precision adhesive-bonded antenna reflector panel

New adhesive-bonded panels are being investigated as a part of an effort to extend and upgrade the 64-m to a 70-m antenna network. Load-deflection tests were conducted on a sample high-precision adhesive-bonded panel for comparison with design criteria. Two computerized structural models were developed in order to predict the deformation patterns under different types of distributed and concentrated loadings. The main purpose was to obtain empirical stiffness factors for the slit beams and girders in the panel structure. With determination and use of the empirical stiffness factors, there is a good agreement between the theoretically predicted deflections and the test measurements. It was also found that the new bonded panels satisfy the stringent design specifications and surface tolerance bounds.

Chian, C. T.↗

Interaction of mixed mode loading on cyclic debonding in adhesively bonded composite joints

A combined experimental and analytical investigation of an adhesively-bonded composite joint was conducted to characterize the fracture mode dependence of cyclic debonding. The system studied consisted of graphite/epoxy adherends bonded with EC 3445 adhesive. Several types of specimens are tested which provide the cyclic debond growth rate measurements under various load conditions: mode 1, mixed mode 1 to 2, and mostly mode 2. This study shows that the total strain-energy-release rate is the governing factor for cyclic debonding.

Mall, S.↗

Evaluation of high temperature structural adhesives for extended service, phase 4

The evaluation of three phenylquinoxaline polymers as high temperature structural adhesives is presented. These included an experimental crisskubjabke oiktner (X-PQ) and two experimental materials (PPQ-2501) and (PPQ-HC). Lap shear, crack extension, and climing drum peel specimens were fabricated from all three polymers, and tested after thermal, combined thermal/humidity, and stressed Skydrol exposure. All three polymers generally performed well as adhesives at initial test temperatures from 219K (-67 F) to 505K (450 F) and after humidity exposure. The 644K (700 F) cured test specimens exhibited superior Skydrol resistance and thermal stability at 505K (450 F) when compared to the 602K (625 F) cured test specimens.

Hendricks, C. L.↗

Fracto-emission accompanying adhesive failure

The fractoemission characteristics of various material interfaces have been investigated experimentally. The interfaces studied include brittle materials/epoxy, glass/elastomers and brittle materials/pressure sensitive adhesives. Results are presented for both large (1 sq cm) planar surfaces together with a few small microns fibers (E-glass, S-glass, Kevlar, and graphite), and a small (10-500 micron) particles in polymer matrices. The composition and energies of the particles emitted during adhesive failure were measured over a wide range of time scales by means of conventional particle counting techniques and photon imaging. Measurements of the time dependence, energy distribution, crack velocity dependence, and spatial distribution of fractoemissive particles are also presented. Some correlations between the various fractoemission components are described in detail.

Dickinson, J. T.↗

Repeatability of mixed-mode adhesive debonding

The repeatability of debond growth rates in adhesively bonded subjected to constant-amplitude cyclic loading was studied. Debond growth rates were compared from two sets of cracked-lap-shear specimens that were fabricated by two different manufacturers and tested in different laboratories. The fabrication method and testing procedures were identical or both sets of specimens. The specimens consisted of aluminum adherends bonded with FM-73 adhesive. Critical values of strain-energy-release rate were also determined from specimens that were monotonically loaded to failure. The test results showed that the debond growth rates for the two sets of specimens were within a scatter band which is similar to that observed in fatigue crack growth in metals. Cyclic debonding occurred at strain-energy-release rates that were more than an order of magnitude less than the critical strain-energy-release rate in static tests.

Everett, R. A., Jr.↗

Tensile adhesion test measurements on plasma-sprayed coatings

Adhesion measurements on plasma-sprayed coatings are briefly studied, including a critical analysis of the experimental scatter for duplicate tests. The application of a simple method which presents adhesion strength data in a fracture mechanics perspective is demonstrated. Available data are analyzed in a way which suggests an approach to finding the overall defect contribution to reducing the apparent strength of coatings.

Berndt, C. C.↗

Adhesive evaluation of LARC-TPI and a water-soluble version of LARC-TPI

The results of a study to evaluate two Langley Research Center thermoplastic polimide (TPI) materials, identified as TPI/MTC for the material from Mitsui Toatsu Chemicals Inc. and TPI/H2O for the material from United Technologies Research Center, as high temperature thermoplastic adhesives and primers for bonding titanium (6AL-4V) adherends are discussed. A limited characterization of the materials was performed using a Diffuse Reflectance-Fourier Transform Infrared Spectroscopy (DR-FTIR) technique. Thermomechanical Analysis (TMA) and torsional braid techniques were used to determine glass transition temperature. The adhesive's strength, as determined by simple lap shear tests, was used to evaluate the effects of long term thermal exposure (up to 1000 hrs) at 204 deg C and a 72-hour water-boil.

Progar, D. J.↗

Interaction of mixed mode loading on cyclic debonding in adhesively bonded composite joints

A combined experimental and analytical investigation of an adhesively-bonded composite joint was conducted to characterize the fracture mode dependence of cyclic debonding. The system studied consisted of graphite/epoxy adherends bonded with EC 3445 adhesive. Several types of specimens are tested which provide the cyclic debond growth rate measurements under various load conditions: mode 1, mixed mode 1 to 2, and mostly mode 2. This study shows that the total strain-energy-release rate is the governing factor for cyclic debonding.

Mall, S.↗

Evaluation of Ti-6Al-4V surface treatments for use with a polyphenylquinoxaline adhesive

Three surface treatments for Ti-6Al-4V adherends were evaluated using a thermoplastic polymer monoether polyphenylquinoxaline, MEPPQ, which had been shown in previous studies to have good potential as a high temperature adhesive for aerospace applications. Initial results based on long term thermal exposure at 232 C (450 F) using the phosphate-fluoride (PF) and chromic acid anodized (CAA) treatments with MEPPQ adhesive were not encouraging. A significant improvement in strength retention and a change in failure mode (cohesive) at 232 C (450F) was found for the SHA treated specimens compared to the PF and CAA treatments. Although an improvement in long term thermal durability was obtained with the SHA treatment of Ti-6Al-4V, an improved surface treatment with better long term durability is still required for aerospace applications.

Progar, D. J.↗

The surface properties of carbon fibers and their adhesion to organic polymers

The state of knowledge of the surface properties of carbon fibers is reviewed, with emphasis on fiber/matrix adhesion in carbon fiber reinforced plastics. Subjects treated include carbon fiber structure and chemistry, techniques for the study of the fiber surface, polymer/fiber bond strength and its measurement, variations in polymer properties in the interphase, and the influence of fiber matrix adhesion on composite mechanical properties. Critical issues are summarized and search recommendations are made.

Bascom, W. D.↗

Space environmental effects on adhesives for the Galileo spacecraft

Requirements for the adhesives used on the Galileo Jovian probe are discussed, and the results of mechanical and radiation experiments for their qualification are presented. The five types of adhesives used for the Wide Field Camera, SXA Antenna, temperature control louvers, and structural bonds all passed the proton and electron tests and the low temperature radiation tests. Possible bond improvements through techniques including gamma ray radiation exposure and ion implantation are also considered.

Bouquet, F. L.↗

Stress ratio effect on cyclic debonding in adhesively bonded composite joints

A study was conducted to investigate the stress ratio effect on cyclic debond growth behavior in adhesively bonded composite joints. The system studied consisted of graphite/epoxy adherends bonded with a toughened epoxy adhesive. This study showed that the strain energy release rate range was the driving factor for cyclic debonding of the tested bonded system when subjected to cyclic loads with different stress ratios for both mode I and mixed mode I-II loadings.

Mall, S.↗

Adhesives For Use In Vacuum, Radiation, And Cold

Report presents results of literature searches and tests of eight adhesives for use in high-radiation, low-temperature, vacuum environment of Galileo spacecraft mission to Jupiter. Used as bonding agents for thermal blankets, instruments, structural members, and coatings. Adhesives tested for contamination, reflectance, bond integrity, color, transmittance, outgassing, dielectric constant, coefficient of thermal expansion, optical interference, peel strength, and shear strength. Some of tests conducted at temperature of liquid nitrogen (-150 degree C).

Bouquet, Frank L.↗

Semi-microdroplet assay for cell adhesion molecules

A new cell-to-cell adhesion assay was devised. Using dissociated embryos of the sea urchin, this procedure involves rotating a 0.100 ml suspension of single cells with 0.100 ml of the solution to be tested in the bulb portion of a transfer pipet with the tip removed. After 1 hour of rotation at 60 rpm at 15 C, the contents of each bulb were transferred into individual wells of a 96 well flat bottom plate. After the plate was incubated for 1 hour at 15 C, black and white photographs were taken with a 35 mm camera attached to an inverted photomicroscope. Examining a proof sheet of the negatives directly allowed a rapid evaluation of suspected cell adhesion promoting factors. A ranking system was used to evaluate all samples. The assay was tested by examining the effect of specific solutions on the aggregation of single cells obtained from dissociated 23 hour embryos.

Tawa, Lawrence Shinzo↗

Adhesion at the interface in cured graphite fiber epoxy-amine resin composites

The effect of high temperature curing on the interface between unsized or epoxy-sized graphite fiber tow and epoxy-amine resin was examined by scanning electron microscopy of compression and freeze fractured specimens. Little or no adhesion was found between the unsized graphite fiber tows and the epoxy-amine resin on curing at 165 C for 17 hrs. Epoxy-sized graphite fibers showed a similar lack of adhesion between the fiber tows and the epoxy-amine resin at 3 and 17 hr cures, although good penetration of the resin into the sized fiber tows had occurred. Interfacial bond strengths for the composites could not be effectively measured by compression fracture of specimens.

Needles, Howard L.↗

Evaluation of Ti-6Al-4V surface treatments for use with a polyphenylquinoxaline adhesive

Three surface treatments for Ti-6Al-4V adherends were evaluated using a thermoplastic polymer monoether polyphenylquinoxaline, MEPPQ, which had been shown in previous studies to have good potential as a high temperature adhesive for aerospace applications. Initial results based on long term thermal exposure at 232 C (450 F) using the phosphate-fluoride (PF) and chromic acid anodized (CAA) treatments with MEPPQ adhesive were not encouraging. A significant improvement in strength retention and a change in failure mode (cohesive) at 232 C (450 F) was found for the SHA treated specimens compared to the PF and CAA treatments. Although an improvement in long term thermal durability was obtained with the SHA treatment of Ti-6Al-4V, an improved surface treatment with better long term durability is still required for aerospace applications.

Progar, Donald J.↗

The use of fluoroepoxy compounds as adhesives to bond fluoroplastics without any surface treatment

The use of fluoroepoxy compounds as adhesives to bond fluoroplastics was investigated. Fluoroepoxy compounds with a F-content higher than 46 percent were able to bond a highly fluorinated plastic such as Teflon PTFE (76 percent F) to give a respectable bond strength without any surface treatment. The advantage of the fluoroepoxy adhesive vanished when applied to a less fluorinated plastic such as Tefzel which contains 55 percent fluorine. Among the curing agents explored, octafluorooctamethylenediamine showed its potential as a cocuring agent for improving both the viscosity of the compound and the flexibility of the cured product.

Lee, Sheng Yen↗

Debonding characteristics of adhesively bonded woven Kevlar composites

The fatigue damage mechanism of an adhesively bonded joint between fabric reinforced composite adherends was investigated with cracked-lap-shear specimens. Two bonded systems were studied: fabric Kevlar 49/5208 epoxy adherends bonded together with either EC 3445 or FM-300 adhesive. For each bonded system, two specimen geometries were tested. In all specimens tested, fatigue damage occurred in the form of cyclic debonding; however, the woven Kevlar specimens gave significantly slower debond growth rates and higher fracture toughness than previously found in the nonwoven adherend specimens. The surfaces for the woven adherends were not smooth; rather, they had regular crests (high spots) and troughs (low spots) due to the weave pattern. Radiographs of the specimens and examination of their failure surfaces revealed that fiber bridging occurred between the crests of the two adherends in the debonded region. The observed improvements in debond growth resistance and static fracture toughness are attributed to this bridging.

Mall, S.↗