Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALIBRATION STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Phase Calibration of Microphones by Measurement in the Free-field

Over the past several years, significant effort has been expended at NASA Langley developing new Micro-Electro-Mechanical System (MEMS)-based microphone directional array instrumentation for high-frequency aeroacoustic measurements in wind tunnels. This new type of array construction solves two challenges which have limited the widespread use of large channel-count arrays, namely by providing a lower cost-per-channel and a simpler method for mounting microphones in wind tunnels and in field-deployable arrays. The current generation of array instrumentation is capable of extracting accurate noise source location and directivity on a variety of airframe components using sophisticated data reduction algorithms [1-2]. Commercially-available MEMS microphones are condenser-type devices and have some desirable characteristics when compared with conventional condenser-type microphones. The most important advantages of MEMS microphones are their size, price, and power consumption. However, the commercially-available units suffer from certain important shortcomings. Based on experiments with array prototypes, it was found that both the bandwidth and the sound pressure limit of the microphones should be increased significantly to improve the performance and flexibility of the microphone array [3]. It was also desired to modify the packaging to eliminate unwanted Helmholtz resonance s exhibited by the commercial devices. Thus, new requirements were defined as follows: Frequency response: 100 Hz to 100 KHz (+/-3dB) Upper sound pressure limit: Design 1: 130 dB SPL (THD less than 5%) Design 2: 150-160 dB SPL (THD less than 5%) Packaging: 3.73 x 6.13 x 1.3 mm can with laser-etched lid. In collaboration with Novusonic Acoustic Innovation, NASA modified a Knowles SiSonic MEMS design to meet these new requirements. Coupled with the design of the enhanced MEMS microphones was the development of a new calibration method for simultaneously obtaining the sensitivity and phase response of the devices over their entire broadband frequency range. Traditionally, electrostatic actuators (EA) have been used to characterize air-condenser microphones; however, MEMS microphones are not adaptable to the EA method due to their construction and very small diaphragm size [4]. Hence a substitution based, free-field method was developed to calibrate these microphones at frequencies up to 80 kHz. The technique relied on the use of a random, ultrasonic broadband centrifugal sound source located in a small anechoic chamber. The free-field sensitivity (voltage per unit sound pressure) was obtained using the procedure outlined in reference 4. Phase calibrations of the MEMS microphones were derived from cross spectral phase comparisons between the reference and test substitution microphones and an adjacent and invariant grazing-incidence 1/8-inch standard microphone. The free-field calibration procedure along with representative sensitivity and phase responses for the new high-frequency MEMS microphones are presented here.

Shams, Qamar A.↗

Simultaneous energy and mass calibration of large-radius jets with the ATLAS detector using a deep neural network

The energy and mass measurements of jets are crucial tasks for the Large Hadron Collider experiments. This paper presents a new calibration method to simultaneously calibrate these quantities for large-radius jets measured with the ATLAS detector using a deep neural network (DNN). To address the specificities of the calibration problem, special loss functions and training procedures are employed, and a complex network architecture, which includes feature annotation and residual connection layers, is used. The DNN-based calibration is compared to the standard numerical approach in an extensive series of tests. The DNN approach is found to perform significantly better in almost all of the tests and over most of the relevant kinematic phase space. In particular, it consistently improves the energy and mass resolutions, with a 30% better energy resolution obtained for transverse momenta $p$ T > $500$ GeV.

47 OTHER INSTRUMENTATION↗

The Quality Assurance Measures for Laser Tracker

Laser tracker as a major survey instrument is widely used in BNL site. There will be totally at least 8 in NSLS, CAD and NSLS-II. The accuracy it can achieve will range from several to hundreds microns due to the effect of instrument performance, methodology, environment and operator etc. NSLS-II project have a very tight requirement to alignment error, for instance, the magnet relative alignment error in one common girder should be better than ±30 micron (2σ). In order to attain this goal, many measures will be taken, which have been elucidated in several technical notes. Those measures will immune the survey and alignment design from a laser tracker of potentially compromised performance; however, it’s still desirable that a precise instrument is present when performing most of the stringent alignment work. This entails the necessity of effective quality assurance for laser tracker system. Although not mandatory, it’s also a good metrology practices to keep them calibrated annually and have the traceability to certain national or international standard (i.e. NIST). However, the sent-out style calibration of laser tracker may cost us the down-time of a month for each tracker every year. It’s not affordable to us as we have a very busy alignment schedule. An in-house monitoring and calibration is strongly desired. This article will discuss the feasibility of calibration laser tracker by us at BNL site. The instrument’s performance will be monitored via the analysis of acquired observations on daily basis. The calibration routine will be carried out at least half-annually. They will be detailed later.

47 OTHER INSTRUMENTATION↗

Quantification of Residual Water in Spent Fuel Dry Storage Canisters Using Mass Spectrometry

The purpose of this report is to document updates on the apparatus to simulate commercial vacuum drying procedures at the Nuclear Energy Work Complex at Sandia National Laboratories. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system during subsequent storage and disposal, such as fuel degradation; cladding corrosion, embrittlement, or breaching; and the creation of a flammable environment via radiolysis of water. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates well-designed investigations of drying process efficacy and water retention. Scaled tests that incorporate relevant physics and well-controlled boundary conditions are essential to provide insight and guidance to the simulation of prototypic systems undergoing drying processes. This report documents details on the quantification of residual water in the Advanced Drying Cycle Simulator (ADCS), an apparatus built to simulate commercial drying procedures and quantify the amount of residual water remaining in a pressurized water reactor (PWR) fuel assembly after drying. The ADCS was constructed with a prototypic 17×17 PWR fuel skeleton and waterproof heater rods to simulate decay heat. The ADCS is outfitted with thermocouples to measure the thermal response of the ADCS to simulated decay heats and internal helium fill pressures relevant to commercial drying procedures. The ADCS is also instrumented with pressure transducers to measure the pressures and vacuum levels observed during simulated commercial drying. The most unique instrumentation used for quantifying residual water in the ADCS is a Hiden Analytical HPR-30 mass spectrometer (MS), which measures gas compositions of the ADCS internal free volume, based on partial pressures calculated from relative proportions of gas molecules detected by the MS. This report details the methodology used to implement MS measurements in quantifying residual water in the ADCS. This methodology includes the calibration of the HPR-30 MS to a Buck Research Instruments CR-4 chilled mirror hygrometer, which itself is calibrated to a NIST-traceable standard. Data collected by both the MS and the chilled mirror hygrometer from water/helium mixtures ranging from 150 to 500,000 ppmv water in helium were used to generate calibration curves, establishing a source of verification of MS measured water contents. Details regarding water content measurement uncertainties are included in this report, defining the accuracy and verifiability of the HPR-30 MS in measuring residual water content in simulated dry storage canister environments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Spectral analysis and temperature measurement during flash sintering under AC electric field

In-situ diffraction experiments were used to study the change in peak profiles of 8YSZ during conventional sintering and flash sintering under AC electric field. Using calibration from a conventionally heated standard, the lattice expansion of 8YSZ under flash conditions was correlated to actual specimen temperature, indicating temperature comparable to that required for conventional sintering. At higher current densities, a temperature rise greater than 2000 °C was reached, which resulted in abnormal grain growth and temperature instability. Microstructural analysis demonstrated that finer grain size can be achieved by limiting the current in order to avoid high specimen temperatures. Experiments varying the thickness of the green compact resulted in higher heat loss due to thermal conduction and corresponding reduction in final density. A replacement to the blackbody radiation model was successfully used to fit the data and explain all effects based on Joule heating as well as provide a flash sintering processing map incorporating furnace temperature, power dissipation, and sample geometry.

36 MATERIALS SCIENCE↗

252 Cf yield calibration method for nuclear material accountancy and safeguards practitioners

Californium-252 is an isotope commonly encapsulated as a physically small but strong spontaneous fission neutron source for applications in industry, academia, and research. Within the nuclear safeguards community, a well-characterized 252 Cf source is often used as an accessible alternative for plutonium in calibrations measurements, which require the absolute source strength. Current methods of source strength quantification can provide an accurate estimate, approximately 1% uncertainty under optimal conditions, but are typically costly and time consuming. An alternative method was developed to determine 252 Cf source strength using passive neutron correlation counting (PNCC). The PNCC method enables institutions and facilities to perform 252 Cf source calibration measurements in-house using detection systems that are common within the nuclear safeguards community. This novel method was previously successfully demonstrated using neutron multiplicity well counters. However, the previous evaluation utilized detection systems with high neutron detection efficiencies, greater than 60%. The purpose of the current study is to extend the previous evaluation and demonstrate the feasibility of the PNCC 252 Cf calibration method for suite of coincidence counters with lower neutron detection efficiencies, between 15% and 35%, which are more commonly encountered in the field, as well as to provide a step-by-step guide to using the method. The neutron source used in this evaluation was previously certified by the National Institutes of Science and Technology (NIST), which provides a reference for the accuracy of the PNCC method. In conclusion, the present source yield calculations demonstrate excellent agreement with a NIST calibration technique and achieve a standard uncertainty below the target 1%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental analysis of a novel and low-cost pin photodiode dosimetry system for diagnostic radiology

Silicon PIN photodiode has recently found broad and exciting applications in the ionizing radiation dosimetry. In this study a compact and novel dosimetry system using a commercially available PIN photodiode (BPW34) has been experimentally tested for diagnostic radiology. The system was evaluated with clinical beams routinely used for diagnostic radiology and calibrated using a secondary reference standard. Measured dose with PIN photodiode (Air Kerma) varied from 10 to 430 μGy for tube voltages from 40 to 100 kVp and tube current from 0.4 to 40 mAs. The minimum detectable organ dose was estimated to be 10 μGy with 20% uncertainty. Results showed a linear correlation between the PIN photodiode readout and dose measured with standard dosimeters spanning doses received. The present dosimetry system having advantages of suitable sensitivity with immediate readout of dose values, low cost, and portability could be used as an alternative to passive dosimetry system such as thermoluminescent dosimeter for dose measurements in diagnostic radiology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved laser-induced desorption spectroscopy (LIDS) for quantified in-situ hydrogen isotope retention measurement and removal from plasma facing materials

A laboratory scale laser induced thermal desorption spectroscopy system is developed and tested on tungsten-deuterium and titanium-deuterium codeposits, and its feasibility as a hydrogenic inventory measurement diagnostic is demonstrated over a range of retention values from 5 × 10 19 m -2 to 7 × 10 23 m -2 for absorbed laser power densities as low as 8 MW m -2 . Codeposit layer samples are grown by magnetron sputtering and immersed in a weak argon rf plasma. A 1 kW fiber laser (λ = 1100 nm) heats the samples up to a peak surface temperature ranging from 900 to 1500 K using pulse widths of 0.5 and 1 s. Spectral line emission from Balmer series Dα and Hα from thermally desorbed deuterium and hydrogen, as well as line emission from argon, are monitored as a function of time using an optical spectrometer with maximum temporal resolution of 1 ms. To correct for wall recycling and pumping speed, and to accurately measure the time evolution of the laser-induced thermal desorption, the raw Dα signal is deconvolved with the system response function, which is obtained by injecting a short burst of D 2 to approximate an impulse. Calibration is done with a standard D 2 leak, and laser induced desorption spectroscopy deuterium retention values are found to be in good agreement with companion measurements made using conventional temperature programmed desorption on samples from the same codeposit batch.

36 MATERIALS SCIENCE↗

Isolating the Lyman alpha forest BAO anomaly

A 2.5-3σ discrepancy has been reported between the baryonic acoustic oscillation peak (BAO) in the Lyman α forest at z ∼ 2.34 and the best fit Planck ΛCDM cosmology. To isolate the origin of the tension, we consider unanchored BAO, in which the standard BAO ruler is not calibrated, eliminating any dependence on cosmology before redshift z ∼ 2.34. We consider BOSS BAO measurements at z ∼ 0.32, 0.57 and 2.34, using the full 2-dimensional constraints on the angular and line of sight BAO scale, as well as isotropic BAO measurements by 6dF and SDSS at z ∼ 0.106 and z ∼ 0.15. We find that the z >0.43 data alone is in 2.9σ of tension with ΛCDM with or without the Planck best fit values of the mass fraction Ω {sub m} and the BAO scale r {sub d} H {sub 0}, indicating that the tension arises not from the ΛCDM parameters but from the dark energy evolution itself at 0.57< z <2.34. This conclusion is supported when the acoustic scale measured by the CMB is included, which further increases the tension and excludes a solution with a constant dark energy equation of state. Including the low z BAO data, which is itself consistent with ΛCDM, reduces the tension to just over 2σ, however in this case a CPL parametrization of the dark energy evolution yields only a modest improvement.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of light production and transport in tellurium dioxide crystals

Simultaneous measurement of phonon and light signatures is an effective way to reduce the backgrounds and increase the sensitivity of CUPID, a next-generation bolometric neutrinoless double-beta decay ($0\nu\beta\beta$) experiment. Light emission in tellurium dioxide (TeO$_2$) crystals, one of the candidate materials for CUPID, is dominated by faint Cherenkov radiation, and the high refractive index of TeO$_2$ complicates light collection. Positive identification of $0\nu\beta\beta$ events therefore requires high-sensitivity light detectors and careful optimization of light transport. A detailed microphysical understanding of the optical properties of TeO$_2$ crystals is essential for such optimization. We present a set of quantitative measurements of light production and transport in a cubic TeO$_2$ crystal, verified with a complete optical model and calibrated against a UVT acrylic standard. We measure the optical surface properties of the crystal, and set stringent limits on the amount of room-temperature scintillation in TeO$_2$ for $\beta$ and $\alpha$ particles of 5.3 and 8 photons / MeV, respectively, at 90% confidence. Finally, the techniques described here can be used to optimize and verify the particle identification capabilities of CUPID.

47 OTHER INSTRUMENTATION↗

Tests of acoustic scale shifts in halo-based mock galaxy catalogues

ABSTRACT We utilize mock catalogues from high-accuracy cosmological N-body simulations to quantify shifts in the recovery of the acoustic scale that could potentially result from galaxy clustering bias. The relationship between galaxies and dark matter haloes presents a complicated source of systematic errors in modern redshift surveys, particularly when aiming to make cosmological measurements to sub-per cent precision. Apart from a scalar, linear bias parameter accounting for the density contrast ratio between matter tracers and the true matter distribution, other types of galaxy bias, such as assembly and velocity biases, may also significantly alter clustering signals from small to large scales. We create mocks based on generalized halo occupation populations of 36 periodic boxes from the abacus cosmosrelease, and test various biased models along with an unbiased base case in a total volume of $48 \, h^{-3} \, {\rm Gpc}^{3}$. Two reconstruction methods are applied to galaxy samples and the apparent acoustic scale is derived by fitting the two-point correlation function multipoles. With respect to the baseline, we find a 0.3 per cent shift in the line-of-sight acoustic scale for one variation in the satellite galaxy population, and we find a 0.7 per cent shift for an extreme level of velocity bias of the central galaxies. All other bias models are consistent with zero shift at the 0.2 per cent level after reconstruction. We note that the bias models explored are relatively large variations, producing sizeable and likely distinguishable changes in small-scale clustering, the modelling of which would further calibrate the baryon acoustic oscillations standard ruler.

79 ASTRONOMY AND ASTROPHYSICS↗

Improved measurement of the half-life of the J π = 8 - nuclear isomer 152m 2 Eu

The standard γ-ray energy calibration source 152 Eu is well known based on the 13.5 y decay of its ground state. Nevertheless, in addition to this decay 152 Eu also has two relatively long-lived isomeric states: a 9 h J π =0 - state at E * =46 keV and a 96 min J π =8 - state at E * =148 keV. In this work, we report a new measurement of the half-lives of both of these isomeric states. Excited states in 152 Eu were populated following the 154 Sm (p,3n) reaction using a 25 MeV proton beam from the K-150 cyclotron at the Cyclotron Institute of Texas A&M University. Post irradiation, γ rays from the de-excitation of the long lived isomeric states were measured using the six BGO shielded high-purity germanium (HPGe) clover detectors that are part of the STARLiTeR array. The half-life of the J π =8 - isomer 152m 2 Eu was obtained by measuring the decrease in intensity of the 90 keV γ ray from the cascade to the ground state. The half-life of this state was measured to be 95.8(4) min which is in agreement with and significantly more precise than the previously measured value of 96(1) min. In a manner similar to the ground state the second long-lived isomer 151m 1 Eu, the J π =0 - state at 46 keV, β decays to excited states in 152 Gd and 152 Sm. Also, the half-life of this state was measured to be 9.39(7) h using five γ-ray transitions.

36 MATERIALS SCIENCE↗

Suppressing Quantum Circuit Errors Due to System Variability

We present a quantum circuit optimization technique that takes into account the variability in error rates that is inherent across present-day noisy quantum computing platforms. This method can be run after qubit routing or postcompilation and consists of computing isomorphic subgraphs to input circuits and scoring each using heuristic cost functions derived from system calibration data. Using an independent standard algorithmic test suite, we show that it is possible to recover on average nearly 40% of missing fidelity using better qubit selection via efficient to compute cost functions. We demonstrate additional performance gains by considering qubit placement over multiple quantum processors. The overhead from these tools is minimal with respect to other compilation steps, such as qubit routing, as the number of qubits increases. As such, our method can be used to find qubit mappings for problems at the scale of quantum advantage and beyond.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast External Quantum Efficiency Measurements of Photovoltaic Modules

The external quantum efficiency (EQE) or associated spectral response is widely used to evaluate the performance of photovoltaics, light emitting diodes, photodetectors, photodiodes, semiconductor lasers, laser-induced refrigeration of solids etc. For photovoltaic (PV) devices, The EQE is used to determine the spectral mismatch correction that is used to convert a performance measurement from a non-ideal simulator spectrum to a standard spectrum in PV device calibrations. Moreover, EQE can provide important insight into the physics of a PV device. For instance, the EQE shape can be used to infer mechanisms limiting the performance of the device. However, EQE measurements of full-size PV modules remain a challenge in the PV community due to rare availability of reliable module QE measurement tools worldwide and the size and complexity of module architecture that comprises several cells connected in strings (series or/and parallel). Here, we use a customized nondestructive tool made of high-power light emitting diodes to perform high-throughput EQE measurements on PV modules. Circuit simulations show that the measurement system can safely be used to measure both crystalline silicon and thin film-based PV modules with series connected cells without the risk of damage through reverse bias. In addition, EQE mapping combined with electroluminescence show a strong correlation and provide a way to determine both spatial non-uniformity of the spectral response and defects/degradation effects across the module.

PV module↗

Sci—Thur PM: Imaging — 04: An iterative triple energy window (TEW) approach to cross talk correction in quantitative small animal Tc99m and In111 SPECT

Dual isotope SPECT allows simultaneous measurement of two different tracers in vivo. With In111 (emission energies of 171keV and 245keV) and Tc99m (140keV), quantification of Tc99m is degraded by cross talk from the In111 photons that scatter and are detected at an energy corresponding to Tc99m. TEW uses counts recorded in two narrow windows surrounding the Tc99m primary window to estimate scatter. Iterative TEW corrects for the bias introduced into the TEW estimate resulting from un-scattered counts detected in the scatter windows. The contamination in the scatter windows is iteratively estimated and subtracted as a fraction of the scatter-corrected primary window counts. The iterative TEW approach was validated with a small-animal SPECT/CT camera using a 2.5mL plastic container holding thoroughly mixed Tc99m/In111 activity fractions of 0.15, 0.28, 0.52, 0.99, 2.47 and 6.90. Dose calibrator measurements were the gold standard. Uncorrected for scatter, the Tc99m activity was over-estimated by as much as 80%. Unmodified TEW underestimated the Tc99m activity by 13%. With iterative TEW corrections applied in projection space, the Tc99m activity was estimated within 5% of truth across all activity fractions above 0.15. This is an improvement over the non-iterative TEW, which could not sufficiently correct for scatter in the 0.15 and 0.28 phantoms.

60 APPLIED LIFE SCIENCES↗

TU-F-CAMPUS-I-03: Preliminary Study of Size-Specific Dose Estimates in Adult Abdomenal CT Examinations in Taiwan

Purpose: This study was to investigate size-specific dose estimates (SSDE) for routine adult abdominal CT examinations in Taiwan. Methods: A national survey was conducted in Taiwan in 2014 to investigate SSDEs for routine adult abdominal CT examinations. The hospitals involved in this study provided CT images of their typical patients. The CT image in the level of the middle liver was selected to record the corresponding tube current, slice mAs or effective mAs. The image was also used to estimate the dimensions of patient as measuring the lengths in the anterior to posterior (AP) and lateral (LAT) directions. The effective diameter was then calculated from AP and LAT, and used to look up conversion factors in the AAPM 204 report. The volume CTDI (CTDIvol) for each CT unit was measured on sites using a 32-cm cylindrical standard dose phantom and a calibrated pencil-type ionization chamber. Individual patient’s SSDEs were then calculated from the corresponding SSDE conversion factor and the CTDIvol. Results: The study cohort included 111 CT units. The ratio of turning on automatic tube current modulation (ATCM) or not is 88:23. Effective diameters are 258.7±25.1 mm (167–366 mm). 99.3% of typical patients selected by each hospital have smaller effective diameter than the 32-cm dosimetry phantom. Adult abdomenal SSDE is 17.5 ± 8.8 mGy (1.9-58 mGy). The SSDE seems to decrease as the effective diameter increases as the ATCM turns off, and independent with the effective diameter as the ATCM turns on. Conclusion: The SSDE for typical patients in Taiwan was investigated. We continue to complete this investigation in 2015 to include more valid data to establish SSDE reference level in Taiwan. This study was financially supported by the Atomic Energy Council in Taiwan.

60 APPLIED LIFE SCIENCES↗

SU-F-J-50: Study On the Magnetic Field Effect On the Exradin W1 Plastic Scintillation Detector

Purpose: To study the response of the Exradin W1 plastic scintillator detector to a 6 MV photon field in the presence of a strong magnetic field (B). Methods: An Exradin W1 scintillator detector coupled to a SuperMax two-channel electrometer, both manufactured by Standard Imaging, Inc., was first calibrated in a Co-60 beam. The Cerenkov Light Ratio (CLR) was obtained following the procedure recommended by the manufacturer. Subtracting signal in channel 2 multiplied by CLR from the signal in channel 1 should lead to a Cerenkov-free signal. The W1 scintillator was placed in a plastic phantom inside a dipole electromagnet (GMW Associates) that could produce a strong B field, and irradiated using a 6 MV beam from an Elekta Versa HD LINAC. Signals from both channels of the W1 scintillator were acquired as a function of B (0 - 1.5 T). Results: The signals from both channels increased as a function of the B field strength. At 1.5 T, channel 1 increased by 11% compared to the baseline (B=0 T), while channel 2 increased by 22%. Applying the recommended Cerenkov correction led to a 2% difference between dose measurement with and without a magnetic field. The values between B=0.3 T and B=1.5 T remained constant. Conclusion: Signals from the Exradin W1 plastic scintillation detector increased as the B field increased. This increase mainly comes from a change in the amount of Cerenkov light coupled within the optical fiber. Removing the Cerenkov component following the procedure recommended by the manufacturer showed to be an effective way to measure dose accurately in strong magnetic fields. The cause for the residual 2% difference is currently under investigation. We acknowledge research support from Elekta AB.

60 APPLIED LIFE SCIENCES↗

Measurement Error and Resolution in Quantitative Stable Isotope Probing: Implications for Experimental Design

Quantitative stable isotope probing (qSIP) estimates isotope tracer incorporation into DNA of individual microbes and can link microbial biodiversity and biogeochemistry in complex communities. As with any quantitative estimation technique, qSIP involves measurement error, and a fuller understanding of error, precision, and statistical power benefits qSIP experimental design and data interpretation. We used several qSIP data sets—from soil and seawater microbiomes—to evaluate how variance in isotope incorporation estimates depends on organism abundance and resolution of the density fractionation scheme. We assessed statistical power for replicated qSIP studies, plus sensitivity and specificity for unreplicated designs. As a taxon’s abundance increases, the variance of its weighted mean density declines. Nine fractions appear to be a reasonable trade-off between cost and precision for most qSIP applications. Increasing the number of density fractions beyond that reduces variance, although the magnitude of this benefit declines with additional fractions. Our analysis suggests that, if a taxon has an isotope enrichment of 10 atom% excess, there is a 60% chance that this will be detected as significantly different from zero (with alpha 0.1). With five replicates, isotope enrichment of 5 atom% could be detected with power (0.6) and alpha (0.1). Finally, we illustrate the importance of internal standards, which can help to calibrate per sample conversions of %GC to mean weighted density. These results should benefit researchers designing future SIP experiments and provide a useful reference for metagenomic SIP applications where both financial and computational limitations constrain experimental scope.

59 BASIC BIOLOGICAL SCIENCES↗