Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVENTIONAL RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Surface daytime net radiation estimation using artificial neural networks

Net all-wave surface radiation (R n ) is one of the most important fundamental parameters in various applications. However, conventional R n measurements are difficult to collect because of the high cost and ongoing maintenance of recording instruments. Therefore, various empirical R n estimation models have been developed. This study presents the results of two artificial neural network (ANN) models (general regression neural networks (GRNN) and Neuroet) to estimate R n globally from multi-source data, including remotely sensed products, surface measurements, and meteorological reanalysis products. R n estimates provided by the two ANNs were tested against in-situ radiation measurements obtained from 251 global sites between 1991–2010 both in global mode (all data were used to fit the models) and in conditional mode (the data were divided into four subsets and the models were fitted separately). Based on the results obtained from extensive experiments, it has been proved that the two ANNs were superior to linear-based empirical models in both global and conditional modes and that the GRNN performed better and was more stable than Neuroet. The GRNN estimates had a determination coefficient (R 2 ) of 0.92, a root mean square error (RMSE) of 34.27 W·m –2 , and a bias of –0.61 W·m –2 in global mode based on the validation dataset. In conclusion, ANN methods are a potentially powerful tool for global R n estimation.

14 SOLAR ENERGY↗

Investigation of workplace-like calibration fields via a deuterium-tritium (D-T) neutron generator

Radiation survey meters and personal dosimeters are typically calibrated in reference neutron fields based on conventional radionuclide sources, such as Americium Beryllium (AmBe) or Californium-252 (252Cf), either unmodified or heavy-water moderated. However, these calibration neutron fields differ significantly from the workplace fields in which most of these survey meters and dosimeters are being used. Although some detectors are designed to yield an approximately dose-equivalent response over a particular neutron energy range, the response of other detectors is highly dependent upon neutron energy. This, in turn, can result in significant over- or underestimation of the intensity of neutron radiation and/or personal dose equivalent determined in the work environment. The use of simulated workplace neutron calibration fields that more closely match those present at the workplace could improve the accuracy of worker, and workplace, neutron dose assessment. This work provides an overview of the neutron fields found around nuclear power reactors and interim spent fuel storage installations based on available data. The feasibility of producing, in an existing calibration facility, workplace-like calibration fields has been investigated via Monte Carlo simulations. Several moderating assembly configurations, paired with a neutron generator using the deuterium tritium (D-T) fusion reaction, were explored

D–T Generator, neutron calibration, workplace neut↗

Categorizing An Explosive Device by its Nuclear Signature (Rev. 1)

This report documents a study to eliminate ambiguity in identifying a very low-yield nuclear detonation in the early stages of the response to such an event. The ambiguity arises from the very similar explosive and radiation effects produced by three categories of explosive devices: An explosively driven radiological dispersal device (RDD) or an accidental explosion in which radiologic material is scattered by chemical explosives. A failed nuclear device in which nuclear material, such as uranium or plutonium, has been scattered by conventional explosives. A nuclear device that, in addition to scattering nuclear material, produced a very low-yield from nuclear fission. The study found that the properties of fission products provide a ready solution to the problem. The radiation dose rate from fission products that were produced in a nearly instantaneous “fission event” decreases extremely rapidly over the first eight hours after that event, whereas nuclear materials and common radiological materials produce an essentially constant dose rate. This contrast provides an unequivocal fission product signature. The measurements required to utilize this signature can be made by first responders with radiation detectors already in the field, on time scales of an hour, although later confirmation using more capable detectors, including spectroscopic capability, is advised. The process of categorizing an explosives-related incident, both pre- and post-detonation, can be represented as a Decision Tree. The Decision Tree illustrates the use of already-fielded radiation detectors to categorize incidents as likely to involve only conventional explosives, an explosively driven RDD, or a nuclear device. The identification of an explosion as a fission event is extremely important to evacuation planners. It has been shown that delayed evacuation after sheltering in place for up to 24 hours after a fission event has the potential to reduce radiation exposure to the affected public and responders by a factor of ten. Traditional evidence collection after a nuclear detonation is likely to be similarly delayed, as the value and urgency of collection efforts must be weighed against radiation and other hazardous exposure of the collectors. The evidence that survives the immediate effects of a nuclear detonation will, in many cases, still be available for collection once radiation levels have diminished to acceptable levels. Certain classes of evidence, notably information stored on digital media, may significantly degrade from exposure to post-detonation radiation fields. Technical nuclear forensics collections will be performed in all events with nuclear yield. Modification of the high-yield collection strategy may be necessary for a very low-yield device.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Response of solidification cellular structures in additively manufactured 316 stainless steel to heavy ion irradiation: an in situ study

In-core or cladding structural materials exposed to heavy ion irradiation often suffer serious irradiation-induced damages. Introducing defect sinks can effectively mitigate irradiation-induced degradation in materials. Here, we investigated the radiation response of additively manufactured 316 austenitic stainless steel with high-density solidification cellular structures via in situ Kr ++ irradiation at 400°C to 5dpa. The study shows that the trapped dislocations along with the cellular walls can serve as effective defect sinks, thus reduce dislocation loop density compared with the conventional coarse-grained counterparts. This study provides a positive step for the potential applications of radiation-resistant, additively manufactured steels in advanced nuclear reactors.

36 MATERIALS SCIENCE↗

A Phase 1/2 Trial of Brief Androgen Suppression and Stereotactic Radiation Therapy (FASTR) for High-Risk Prostate Cancer

Purpose: To initiate a phase 1/2 trial to examine the tolerability of a condensed combined-modality protocol for high-risk prostate cancer. Methods and Materials: Men scoring ≥3 on the Vulnerable Elderly Scale (VES) or refusing conventionally fractionated treatment for high-risk prostate cancer were eligible to participate. Androgen suppression was delivered for 12 months, and radiation therapy was delivered using 25 Gy to pelvic nodes delivered synchronously with 40 Gy to the prostate given as 1 fraction per week over 5 weeks. The phase 1 component included predetermined stopping rules based on 6-month treatment-related toxicity, with trial suspension specified if there were ≥6 of 15 patients (40%) or ≥3 of 15 (20%) who experienced grade ≥2 or ≥3 gastrointestinal (GI) or genitourinary (GU) toxicity, respectively. Results: Sixteen men were enrolled, with 7 men meeting the criteria of VES ≥3 and 9 men having a VES <3 but choosing the condensed treatment. One man was not treated owing to discovery of a synchronous primary rectal cancer. Four patients (26%) experienced grade ≥2 toxicity at 6 weeks after treatment. There were 9 of 15 (60%) who experienced grade ≥2 GI or GU toxicity and 4 of 15 (26%) grade ≥3 GI or GU toxicity at 6 months, and 5 of 15 (30%) grade ≥2 GI and GU toxicity at 6 months. A review of the 15 cases did not identify any remedial changes, thus the phase 1 criteria were not met. Conclusion: This novel condensed treatment had higher than anticipated late toxicities and was terminated before phase 2 accrual. Treatment factors, such as inclusion of pelvic lymph node radiation therapy, planning constraints, and treatment margins, or patient factors related to the specific frail elderly population may be contributing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Numerical investigation of laser radiation conversion to X rays in experiments with spherical boxes with interior coatings of different materials

The dynamics of laser and X-ray radiation fields in experiments with spherical boxes was numerically investigated in a sector approximation using the SND-LIRA numerical code. The experiments were performed on the Iskra-5 laser facility at a wavelength {lambda}=0.657 {mu}m (the second harmonic of iodine laser radiation). The characteristics of X-ray generation were investigated with the inner surface of a converter box coated with different-Z materials (Au, Cu, Mg). With lowering Z, the laser energy absorption coefficient k{sub a} decreases and there occurs a lowering of the effective X-ray radiation temperature. Our calculations reveal a strong dependence of the results on the electron free-streaming flux limitation f. In particular, on lowering f from 0.1 to 0.03 for a conventional box with a gold coating, the coefficient k{sub a} decreases from 0.83 to 0.5 and the peak X-ray radiation temperature drops from 170 to 150eV. In these calculations, the rms nonuniformity of the X-ray irradiation of a capsule with thermonuclear fuel amounted to 1%-3%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ionic Liquids: Radiation Chemistry, Solvation Dynamics and Reactivity Patterns

Ionic liquids (ILs) are a rapidly expanding family of condensed-phase media with important applications in energy production, nuclear fuel and waste processing, improving the efficiency and safety of industrial chemical processes, and pollution prevention. ILs generally have low volatilities and are combustion-resistant, highly conductive, recyclable and capable of dissolving a wide variety of materials. They are finding new uses in chemical synthesis, catalysis, separations chemistry, electrochemistry and other areas. Ionic liquids have dramatically different properties compared to conventional molecular solvents, and they provide a new and unusual environment to test our theoretical understanding of primary radiation chemistry, charge transfer and other reactions. We are interested in how IL properties influence physical and dynamical processes that determine the stability and lifetimes of reactive intermediates and thereby affect the courses of reactions and product distributions. We study these issues by characterization of primary radiolysis products and measurements of their yields and reactivity, quantification of electron solvation dynamics and scavenging of electrons in different states of solvation. From this knowledge we wish to learn how to predict radiolytic mechanisms and control them or mitigate their effects on the properties of materials used in nuclear fuel processing, for example, and to apply IL radiation chemistry to answer questions about general chemical reactivity in ionic liquids that will aid in the development of applications listed above. Very early in our radiolysis studies it became evident that the slow solvation dynamics of the excess electron in ILs (which vary over a wide viscosity range) increase the importance of pre-solvated electron reactivity and consequently alter product distributions and subsequent chemistry. This difference from conventional solvents has profound effects on predicting and controlling radiolytic yields, which need to be quantified for the successful use under radiolytic conditions. Electron solvation dynamics in ILs are measured directly when possible and estimated using proxies (e.g. coumarin-153 dynamic emission Stokes shifts or benzophenone anion solvation) in other cases. Electron reactivity is measured using ultrafast kinetics techniques for comparison with the solvation process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of radiometric errors on accuracy of temperature-profile measurement by spectral scanning using absorption-emission pyrometry

The spectral-scanning method may be used to determine the temperature profile of a jet- or rocket-engine exhaust stream by measurements of gas radiation and transmittance, at two or more wavelengths. A single, fixed line of sight is used, using immobile radiators outside of the gas stream, and there is no interference with the flow. At least two sets of measurements are made, each set consisting of the conventional three radiometric measurements of absorption-emission pyrometry, but each set is taken over a different spectral interval that gives different weight to the radiation from a different portion of the optical path. Thereby, discrimination is obtained with respect to location along the path. A given radiometric error causes an error in computed temperatures. The ratio between temperature error and radiometric error depends on profile shape, path length, temperature level, and strength of line absorption, and the absorption coefficient and its temperature dependency. These influence the choice of wavelengths, for any given gas. Conditions for minimum temperature error are derived. Numerical results are presented for a two-wavelength measurement on a family of profiles that may be expected in a practical case of hydrogen-oxygen combustion. Under favorable conditions, the fractional error in temperature approximates the fractional error in radiant-flux measurement.

Buchele, D. R.↗

SU-F-P-05: Initial Experience with an Independent Certification Program for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

Purpose: The ASTRO document “Safety is no accident: A FRAMEWORK FOR QUALITY RADIATION ONCOLOGY AND CARE” recommends external reviews of specialized modalities. The purpose of this presentation is to describe the implementation of such a program for Stereotactic Radiosurgery (SRS) and Stereotactic Body radiation Therapy (SBRT). Methods: The margin of error for SRS and SBRT delivery is significantly smaller than that of conventional radiotherapy and therefore requires special attention and diligence. The Novalis Certified program was created to fill an unmet need for specialized SRS / SBRT credentialing. A standards document was drafted by a panel of experts from several disciplines, including medical physics, radiation oncology and neurosurgery. The document, based on national and international standards, covers requirements in program structure, personnel, training, clinical application, technology, quality management, and patient and equipment QA. The credentialing process was modeled after existing certification programs and includes an institution-generated self-study, extensive document review and an onsite audit. Reviewers generate a descriptive report, which is reviewed by a multidisciplinary expert panel. Outcomes of the review may include mandatory requirements and optional recommendations. Results: 15 institutions have received Novalis Certification, including 3 in the US, 7 in Europe, 4 in Australia and 1 in Asia. 87 other centers are at various stages of the process. Nine reviews have resulted in mandatory requirements, however all of these were addressed within three months of the audit report. All reviews have produced specific recommendations ranging from programmatic to technical in nature. Institutions felt that the credentialing process addressed a critical need and was highly valuable to the institution. Conclusion: Novalis Certification is a unique peer review program assessing safety and quality in SRS and SBRT, while recognizing international practice standards. The approach is capable of highlighting outstanding requirements and providing recommendations to enhance both new and established programs. Timothy Solberg is co-owner of Global Radiosurgery services, LLC.

60 APPLIED LIFE SCIENCES↗

2D Rotational Angiography for Fast and Standardized Evaluation of Peripheral and Visceral Artery Stenoses

Purpose: To investigate the value of rotational digital subtraction angiography (rDSA) for evaluation of peripheral and visceral artery stenoses compared to conventional digital subtraction angiography (cDSA). Methods: A phantom study was performed comparing the radiation dose of cDSA with two projections and rDSA by means of the 2D Dynavision technique (Siemens Medical Solutions, Forchheim, Germany). Subsequently, 33 consecutive patients (18 women, 15 men; mean {+-} SD age 67 {+-} 15 years) were examined by both techniques. In total, 63 vessel segments were analyzed by two observers with respect to stenoses, image contrast, and vessel sharpness. Results: Radiation dose was significantly lower with rDSA. cDSA and rDSA revealed 21 and 24 flow-relevant stenotic lesions and vessel occlusions (70-100%), respectively. The same stenosis grade was assessed in 45 segments. By means of rDSA, 10 lesions were judged to have a higher and 8 lesions a lower stenosis grade compared to cDSA. rDSA yielded additive information regarding the vessel anatomy and pathology in 29 segments. However, a tendency toward better image quality and sharper vessel visualization was seen with cDSA. Conclusion: rDSA allows for multiprojection assessment of peripheral and visceral arteries and provides additional clinically relevant information after a single bolus of contrast medium. At the same time, radiation dose can be significantly reduced compared to cDSA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiotherapy Doses of 80 Gy and Higher Are Associated With Lower Mortality in Men With Gleason Score 8 to 10 Prostate Cancer

Purpose: Men with Gleason score (GS) 8-10 prostate cancer (PCa) are assumed to have a high risk of micrometastatic disease at presentation. However, local failure is also a major problem. We sought to establish the importance of more aggressive local radiotherapy (RT) to {>=}80 Gy. Methods and Materials: There were 226 men treated consecutively with RT {+-} ADT from 1988 to 2002 for GS 8-10 PCa. Conventional, three-dimensional conformal or intensity-modulated (IM) RT was used. Radiation dose was divided into three groups: (1) <75 Gy (n = 50); (2) 75-79.9 Gy (n = 60); or (3) {>=}80 Gy (n = 116). The endpoints examined included biochemical failure (BF; nadir + 2 definition), distant metastasis (DM), cause-specific mortality, and overall mortality (OM). Results: Median follow-up was 66, 71, and 58 months for Groups 1, 2, and 3. On Fine and Gray's competing risk regression analysis, significant predictors of reduced BF were RT dose {>=}80 Gy (p = 0.011) and androgen deprivation therapy duration {>=}24 months (p = 0.033). In a similar model of DM, only RT dose {>=}80 Gy was significant (p = 0.007). On Cox regression analysis, significant predictors of reduced OM were RT dose {>=}80 Gy (p = 0.035) and T category (T3/4 vs. T1, p = 0.041). Dose was not a significant determinant of cause-specific mortality. Results for RT dose were similar in a model with RT dose and ADT duration as continuous variables. Conclusion: The results indicate that RT dose escalation to {>=}80 Gy is associated with lower risks of BF, DM, and OM in men with GS 8-10 PCa, independently of androgen deprivation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In situ measurement of temperature and reduction of rutile titania using energy dispersive x-ray diffraction

Using in situ energy dispersive x-ray diffraction (EDXRD) the average specimen temperature of TiO 2 in the steady state of flash is experimentally determined. Comparison of the microstructure for flash sintering and conventional sintering in addition to the temperature determined from calibration of the unit cell expansion indicates that rapid Joule heating during flash sintering causes densification and grain growth comparable with conventional sintering. An average temperature approximation model is proposed to account for greybody radiation and thermal conduction. In conclusion, the inhomogeneity of the grain growth across the sample length is confirmed to correlate with inhomogeneity in temperature distribution and this suggests a current induced Peltier effect in n-type TiO 2 .

36 MATERIALS SCIENCE↗

Nonlinear effects in ultrasound fields of diagnostic-type transducers used for kidney stone propulsion: Characterization in water

Newer imaging and therapeutic ultrasound technologies require higher in situ pressure levels compared to conventional diagnostic values. One example is the recently developed use of focused ultrasonic radiation force to move kidney stones and residual fragments out of the urinary collecting system. A commercial diagnostic 2.3 MHz C5-2 array probe is used to deliver the acoustic pushing pulses. The probe comprises 128 elements equally spaced at the 55 mm long convex cylindrical surface with 38 mm radius of curvature. The efficacy of the treatment can be increased by using higher intensity at the focus to provide stronger pushing force; however, nonlinear acoustic saturation can be a limiting factor. In this work nonlinear propagation effects were analyzed for the C5-2 transducer using a combined measurement and modeling approach. Simulations were based on the 3D Westervelt equation; the boundary condition was set to match the focal geometry of the beam as measured at a low power output. Focal waveforms simulated for increased output power levels were compared with the fiber-optic hydrophone measurements and were found in good agreement. It was shown that saturation effects do limit the acoustic pressure in the focal region of the transducer. This work has application to standard diagnostic probes and imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A UNIFORM CORRELATION BETWEEN SYNCHROTRON LUMINOSITY AND DOPPLER FACTOR IN GAMMA-RAY BURSTS AND BLAZARS: A HINT OF SIMILAR INTRINSIC LUMINOSITIES?

We compile 23 gamma-ray bursts (GRBs) and 21 blazars with estimated Doppler factors, and the Doppler factors of GRBs are estimated from their Lorentz factors by assuming their jet viewing angles {theta} {yields} 0{sup 0}. Using the conventional assumption that the prompt emission of GRBs is dominated by the synchrotron radiation, we calculate the synchrotron luminosity of GRBs from their total isotropic energy and burst duration. Intriguingly, we discover a uniform correlation between the synchrotron luminosity and Doppler factor, L{sub syn}{proportional_to}D{sup 3.1}, for GRBs and blazars, which suggests that they may share some similar jet physics. One possible reason is that GRBs and blazars have, more or less, similar intrinsic synchrotron luminosities and both of them are strongly enhanced by the beaming effect. After Doppler and redshift correction, we find that the intrinsic peak energy of the GRBs ranges from 0.1 to 3 keV with a typical value of 1 keV. We further correct the beaming effect for the observed luminosity of GRBs and find that a positive correlation exists between the intrinsic synchrotron luminosity and peak energy for GRBs, which is similar to that of blazars. Our results suggest that both the intrinsic positive correlation and the beaming effect may be responsible for the observed tight correlation between the isotropic energy and the peak energy in GRBs (the so-called Amati relation).

79 ASTRONOMY AND ASTROPHYSICS↗

Radiation damage in protein serial femtosecond crystallography using an x-ray free-electron laser

X-ray free-electron lasers deliver intense femtosecond pulses that promise to yield high resolution diffraction data of nanocrystals before the destruction of the sample by radiation damage. Diffraction intensities of lysozyme nanocrystals collected at the Linac Coherent Light Source using 2 keV photons were used for structure determination by molecular replacement and analyzed for radiation damage as a function of pulse length and fluence. Signatures of radiation damage are observed for pulses as short as 70 fs. Parametric scaling used in conventional crystallography does not account for the observed effects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tomographic image via background subtraction using an x-ray projection image and a priori computed tomography

Kilovoltage x-ray projection images (kV images for brevity) are increasingly available in image guided radiotherapy (IGRT) for patient positioning. These images are two-dimensional (2D) projections of a three-dimensional (3D) object along the x-ray beam direction. Projecting a 3D object onto a plane may lead to ambiguities in the identification of anatomical structures and to poor contrast in kV images. Therefore, the use of kV images in IGRT is mainly limited to bony landmark alignments. This work proposes a novel subtraction technique that isolates a slice of interest (SOI) from a kV image with the assistance of a priori information from a previous CT scan. The method separates structural information within a preselected SOI by suppressing contributions to the unprocessed projection from out-of-SOI-plane structures. Up to a five-fold increase in the contrast-to-noise ratios (CNRs) was observed in selected regions of the isolated SOI, when compared to the original unprocessed kV image. The tomographic image via background subtraction (TIBS) technique aims to provide a quick snapshot of the slice of interest with greatly enhanced image contrast over conventional kV x-ray projections for fast and accurate image guidance of radiation therapy. With further refinements, TIBS could, in principle, provide real-time tumor localization using gantry-mounted x-ray imaging systems without the need for implanted markers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Second Target Station Target Streaming for the Preliminary Design of the Target Assembly

This report documents the analysis of dose rate fields from a combination of two sources stemming from the target system of the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS) Second Target Station (STS). This analysis supports the target drive components’ lifetime estimates and conventional facilities’ preliminary design. The two sources detailed in this report are the radiation generated by the proton beam incident on the target and the activated cooling water in the pipes at the top of the target assembly. The analysis considers the STS target system in operational configuration, with all shielding in place. The dose rate fields are calculated in the target drive room and through the target drive room ceiling. This report calculates the thickness necessary for the target drive room’s high-density concrete ceiling to meet the 0.25 mrem/hr dose limit requirement in the high bay directly above the target drive room. In addition to sizing the target drive room ceiling, this report includes details of the dose field surrounding the target drive assembly to estimate the deposited dose in the target drive assembly components resulting from both streaming and decay of activated water. Prompt neutrons and gammas generated by the proton beam incident on the target primarily stream along the gaps between the target assembly and core vessel shielding. Because the models and analysis detailed in this report are based on the STS preliminary design, future analysis is needed to support the STS final design.

43 PARTICLE ACCELERATORS↗

YALINA facility a sub-critical Accelerator- Driven System (ADS) for nuclear energy research facility description and an overview of the research program (1997-2008).

The YALINA facility is a zero-power, sub-critical assembly driven by a conventional neutron generator. It was conceived, constructed, and put into operation at the Radiation Physics and Chemistry Problems Institute of the National Academy of Sciences of Belarus located in Minsk-Sosny, Belarus. This facility was conceived for the purpose of investigating the static and dynamic neutronics properties of accelerator driven sub-critical systems, and to serve as a neutron source for investigating the properties of nuclear reactions, in particular transmutation reactions involving minor-actinide nuclei. This report provides a detailed description of this facility and documents the progress of research carried out there during a period of approximately a decade since the facility was conceived and built until the end of 2008. During its history of development and operation to date (1997-2008), the YALINA facility has hosted several foreign groups that worked with the resident staff as collaborators. The participation of Argonne National Laboratory in the YALINA research programs commenced in 2005. For obvious reasons, special emphasis is placed in this report on the work at YALINA facility that has involved Argonne's participation. Attention is given here to the experimental program at YALINA facility as well as to analytical investigations aimed at validating codes and computational procedures and at providing a better understanding of the physics and operational behavior of the YALINA facility in particular, and ADS systems in general, during the period 1997-2008.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗