Search NASA⌕ Search

SEARCH · Search NASA

Results for “CT Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

TU-F-BRF-09: Feasibility Study of Spatial and Temporal Fractionation Using a Table-Top Image-Guided MRT System

Purpose: Microbeam radiation therapy is a promising experimental radiotherapy method for cancer treatment. Synchrotron studies have shown that MRT can preferentially ablate tumors while mostly preserving the surrounding normal tissues. Our purpose is to develop a compact microbeam irradiator that can be accessible for laboratory research on MRT's therapeutic mechanism, with the ultimate goal of translating this technique for clinical applications. Utilizing a carbon nanotube field emission X-ray source array, our lab has developed a first of its kind table-top microbeam irradiator. The purpose of this study is to investigate the possibility of increasing the total dose to the tumor region using spatial and temporal fractionation. Methods: MRI and CT scans were acquired and registered to locate both the target region and the landmark in the treatment coordinate space. A crossbeam treatment configuration was planned to achieve the desired dosage and tumor coverage. One array of 300 μm-thick microbeams was delivered to the target on the first day. Another array, perpendicular to the first one, was delivered the next day targeting the same region. The feasibility of this image-guided MRT procedure was evaluated using a phantom. Gafchromic EBT2 film was employed to characterize the targeting accuracy and the delivered tumor dose. Results: The preliminary phantom study showed that a cross-pattern of microbeam arrays was successfully delivered with sub-millimeter targeting accuracy. The delivered dose in the target region was doubled. The fraction of tumor volume that received the peak dose was increased. Conclusion: Temporal fractionation of crosspatterned microbeams can be delivered to the same target region. The feasibility of this procedure was investigated with a phantom study. Once implemented, this procedure has the potential of increasing the tumor control effect of MRT and of achieving better normal tissue recovery.

60 APPLIED LIFE SCIENCES↗

WE-A-17A-06: Evaluation of An Automatic Interstitial Catheter Digitization Algorithm That Reduces Treatment Planning Time and Provide Means for Adaptive Re-Planning in HDR Brachytherapy of Gynecologic Cancers

Purpose: To evaluate an automatic interstitial catheter digitization algorithm that reduces treatment planning time and provide means for adaptive re-planning in HDR Brachytherapy of Gynecologic Cancers. Methods: The semi-automatic catheter digitization tool utilizes a region growing algorithm in conjunction with a spline model of the catheters. The CT images were first pre-processed to enhance the contrast between the catheters and soft tissue. Several seed locations were selected in each catheter for the region growing algorithm. The spline model of the catheters assisted in the region growing by preventing inter-catheter cross-over caused by air or metal artifacts. Source dwell positions from day one CT scans were applied to subsequent CTs and forward calculated using the automatically digitized catheter positions. This method was applied to 10 patients who had received HDR interstitial brachytherapy on an IRB approved image-guided radiation therapy protocol. The prescribed dose was 18.75 or 20 Gy delivered in 5 fractions, twice daily, over 3 consecutive days. Dosimetric comparisons were made between automatic and manual digitization on day two CTs. Results: The region growing algorithm, assisted by the spline model of the catheters, was able to digitize all catheters. The difference between automatic and manually digitized positions was 0.8±0.3 mm. The digitization time ranged from 34 minutes to 43 minutes with a mean digitization time of 37 minutes. The bulk of the time was spent on manual selection of initial seed positions and spline parameter adjustments. There was no significance difference in dosimetric parameters between the automatic and manually digitized plans. D90% to the CTV was 91.5±4.4% for the manual digitization versus 91.4±4.4% for the automatic digitization (p=0.56). Conclusion: A region growing algorithm was developed to semi-automatically digitize interstitial catheters in HDR brachytherapy using the Syed-Neblett template. This automatic digitization tool was shown to be accurate compared to manual digitization.

60 APPLIED LIFE SCIENCES↗

WE-A-17A-09: Exploiting Electromagnetic Technologies for Real-Time Seed Drop Position Validation in Permanent Implant Brachytherapy

Purpose: To report on preliminary results validating the performance of a specially designed LDR brachytherapy needle prototype possessing both electromagnetic (EM) tracking and seed drop detection abilities. Methods: An EM hollow needle prototype has been designed and constructed in collaboration with research partner Philips Healthcare. The needle possesses conventional 3D tracking capabilities, along with a novel seed drop detection mechanism exploiting local changes of electromagnetic properties generated by the passage of seeds in the needle's embedded sensor coils. These two capabilities are exploited by proprietary engineering and signal processing techniques to generate seed drop position estimates in real-time treatment delivery. The electromagnetic tracking system (EMTS) used for the experiment is the NDI Aurora Planar Field Generator. The experiment consisted of dropping a total of 35 seeds in a prismatic agarose phantom, and comparing the 3D seed drop positions of the EMTS to those obtained by an image analysis of subsequent micro-CT scans. Drop position error computations and statistical analysis were performed after a 3D registration of the two seed distributions. Results: Of the 35 seeds dropped in the phantom, 32 were properly detected by the needle prototype. Absolute drop position errors among the detected seeds ranged from 0.5 to 4.8 mm with mean and standard deviation values of 1.6 and 0.9 mm, respectively. Error measurements also include undesirable and uncontrollable effects such as seed motion upon deposition. The true accuracy performance of the needle prototype is therefore underestimated. Conclusion: This preliminary study demonstrates the potential benefits of EM technologies in detecting the passage of seeds in a hollow needle as a means of generating drop position estimates in real-time treatment delivery. Such tools could therefore represent a potentially interesting addition to existing brachytherapy protocols for rapid dosimetry validation. Equipments and fundings for this project were provided by Philips Medical.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-E-18A-11: Fluoro-Tomographic Images From Projections of On-Board Imager (OBI) While Gantry Is Moving

Purpose: A method to generate a series of fluoro-tomographic images (FTI) of the slice of interest (SOI) from the projection images of the On-board imager (OBI) while gantry is moving is developed and tested. Methods: Tomographic image via background subtraction, TIBS has been published by our group. TIBS uses a priori anatomical information from a previous CT scan to isolate a SOI from a planar kV image by factoring out the attenuations by tissues outside the SOI (background). We extended the idea to 4D TIBS, which enables to generate from the projection of different gantry angles. A set of background images for different angles are prepared. A background image at a given gantry angle is subtracted from the projection image at the same angle to generate a TIBS image. Then the TIBS image is converted to a reference angle. The 4D TIBS is the set of TIBS that originated from gantry angles other than the reference angle. Projection images of lung patients for CBCT acquisition are used to test the 4D TIBS. Results: Fluoroscopic images of a coronal plane of lung patients are acquired from the CBCT projections at different gantry angles and times. Change of morphology of hilar vessels due to breathing and heart beating are visible in the coronal plane, which are generated from the set of the projection images at gantry angles other than antero-posterior. Breathing surrogate or sorting process is not needed. Unlike tomosynthesis, FTI from 4D TIBS maintains the independence of each of the projections thereby reveals temporal variations within the SOI. Conclusion: FTI, fluoroscopic imaging of a SOI with x-ray projections, directly generated from the x-ray projection images at different gantry angles is tested with a lung case and proven feasible. This technique can be used for on-line imaging of moving targets. NIH Grant R01CA133539.

60 APPLIED LIFE SCIENCES↗

WE-G-17A-04: Measurements of the Electron-Return-Effect in a Commercial Magnetic Resonance Image Guided Radiation Therapy (MR-IGRT) System

Purpose: The aim of this work was to measure the influences of the Lorentz force (electron return effect) on secondary electron transport in the presence of a low magnetic field produced in a commercial MR-IGRT system using a custom heterogeneous phantom. Methods: A commercial MR-IGRT system has been commissioned in our department. The system combines real-time imaging using a split-bore 0.35-T MRI and three Co-60 heads, each collimated with a doubly-focused MLC. The integrated treatment planning system uses a Monte-Carlo algorithm that models the magnetic field effects on scattered electrons. During commissioning, a custom heterogeneity phantom was designed to acquire ionization chamber and film measurements. The 30 cm cubic phantom consists of two waterfilled annuli, each containing a central region that simulates a 6 cm cubic lung tumor using polystyrene embedded in cork. Film may be placed inbetween the halves, and small-volume ionization chambers may be placed in different positions to measure dose to the tumor and near interfaces where the electron return effect is expected. The treatment planning system was used to create open-field and IMRT treatment plans on a CT scan of the phantom. Plans were delivered to the phantom, and radiographic film and ionization chamber measurements were obtained. Results: The mean ionization chamber measured dose ratio for 27 measurements for 5 plans was 0.993 ± 0.027. Lateral profile film measurements confirm that the electron-return-effect is observable, producing local dose variations of less than 10% over 5 mm with 0.35 T magnetic field for single field treatment plans. The effect becomes negligible for opposing-field and IMRT treatments. Conclusion: A heterogeneous phantom for measurement of the electron-return-effect has been designed. Ionization chamber and film measurements made with the phantom indicate that the dosimetric effect is minimal, and the treatment planning system predicts dose reasonably well for complex heterogeneous scenarios.

60 APPLIED LIFE SCIENCES↗

TH-A-19A-10: Fast Four Dimensional Monte Carlo Dose Computations for Proton Therapy of Lung Cancer

Purpose: To develop and validate a fast and accurate four dimensional (4D) Monte Carlo (MC) dose computation system for proton therapy of lung cancer and other thoracic and abdominal malignancies in which the delivered dose distributions can be affected by respiratory motion of the patient. Methods: A 4D computer tomography (CT) scan for a lung cancer patient treated with protons in our clinic was used to create a time dependent patient model using our in-house, MCNPX-based Monte Carlo system (“MC{sup 2}”). The beam line configurations for two passively scattered proton beams used in the actual treatment were extracted from the clinical treatment plan and a set of input files was created automatically using MC{sup 2}. A full MC simulation of the beam line was computed using MCNPX and a set of phase space files for each beam was collected at the distal surface of the range compensator. The particles from these phase space files were transported through the 10 voxelized patient models corresponding to the 10 phases of the breathing cycle in the 4DCT, using MCNPX and an accelerated (fast) MC code called “FDC”, developed by us and which is based on the track repeating algorithm. The accuracy of the fast algorithm was assessed by comparing the two time dependent dose distributions. Results: The error of less than 1% in 100% of the voxels in all phases of the breathing cycle was achieved using this method with a speedup of more than 1000 times. Conclusion: The proposed method, which uses full MC to simulate the beam line and the accelerated MC code FDC for the time consuming particle transport inside the complex, time dependent, geometry of the patient shows excellent accuracy together with an extraordinary speed.

60 APPLIED LIFE SCIENCES↗

TH-A-18C-10: Dynamic Intensity Weighted Region of Interest Imaging

Purpose: For image guidance tasks full image quality is not required throughout the entire image. With dynamic filtration of the kV imaging beam the noise properties of the CT image can be locally controlled, providing a high quality image around the target volume with a lower quality surrounding region while providing substantial dose sparing to the patient as well as reduced scatter fluence on the detector. Methods: A dynamic collimation device with 3mm copper blades has been designed to mount in place of the bowtie filter on the On-Board Imager (Varian Medical Systems). The beam intensity is reduced by 95% behind the copper filters and the aperture is controlled dynamically to conformally illuminate a given ROI during a standard cone-beam CT scan. A data correction framework to account for the physical effects of the collimator prior to reconstruction was developed. Furthermore, to determine the dose savings and scatter reduction a monte carlo model was built in BEAMnrc with specifics from the Varian Monte Carlo Data Package. The MC model was validated with Gafchromic film. Results: The reconstructed image shows image quality comparable to a standard scan in the specified ROI, with higher noise and streaks in the outer region but still sufficient information for alignment to high contrast structures. The monte carlo modeling showed that the scatter-to-primary ratio was reduced from 1.26 for an unfiltered scan to 0.45 for an intensity weighted scan, suggesting that image quality may be improved in the inner ROI. Dose in the inner region was reduced 10–15% due to reduced scatter and by as much as 75% in the outer region. Conclusion: Dynamic intensity-weighted ROI imaging allows reduction of imaging dose to sensitive organs away from the target region while providing images that retain their utility for patient setup and procedure guidance. Funding was provided in part by Varian Medical Systems and NIH Grants 1RO1CA120540, T32EB002103, S10 RR021039 and P30 CA14599. The contents of this work are solely the responsibility of the authors and do not necessarily represent the official views of any of the supporting organizations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-19A-01: A Simple Deep Inspiration Breath Hold System

Purpose: Deep Inspiration Breath Hold (DIBH) Radiation therapy for left sided breast can reduce dose to the lungs and heart. The purpose of this work is to illustrate how to implement a simple method of DIBH for simulation and treatment using equipment readily available in most radiation oncology clinics. Methods: For simulation and treatment, a foam block is placed on the patient's abdomen or chest and a horizontal laser mounted on a movable slide is aimed at the center of the foam block. After a coaching session the block is marked at the average free breathing position and average DIBH position. The position of block relative to laser can be seen by the patient via prism glasses as well as the radiation therapists via a video camera system. Simulation CT scans and treatment delivery are performed under DIBH conditions. Imaging and treatment are performed by manually turning the beam on once the patient has achieved DIBH after being given verbal instructions. Results: Manually triggered imaging was used daily to verify DIBH reproducibility for all patients treated using this system. Sets of before and during port images were used to ensure patient position was appropriate for treatment. Results of the laser on block method were compared to a sister facility using surface mapping techniques for DIBH and the two methods were found to have clinically equivalent reproducibility. Conclusion: The laser and block system was found to be simple to implement and robust during patient treatment. This system can be created from readily available materials at low cost and provides adequate feedback to patient and therapists. During treatment images document the reproducibility of setup and give confidence to clinicians that this method is reproducible from day to day.

60 APPLIED LIFE SCIENCES↗

SU-C-BRD-06: Results From a 5 Patient in Vivo Rectal Wall Dosimetry Study Using Plastic Scintillation Detectors

Purpose: To evaluate the performance characteristics of plastic scintillation detectors (PSDs) in an in vivo environment for external beam radiation, and to establish the usefulness and ease of implementation of a PSD based in vivo dosimetry system for routine clinical use. Methods: A five patient IRB approved in vivo dosimetry study was performed. Five patients with prostate cancer were enrolled and PSDs were used to monitor rectal wall dose and verify the delivered dose for approximately two fractions each week over the course of their treatment (approximately fourteen fractions), resulting in a total of 142 in vivo measurements. A set of two PSDs was fabricated for each patient. At each monitored fraction the PSDs were attached to the anterior surface of an endorectal balloon used to immobilize the patient's prostate during treatment. A CT scan was acquired with a CTon- rails linear accelerator to localize the detectors and to calculate the dose expected to be delivered to the detectors. Each PSD acquired data in 10 second intervals for the duration of the treatment. The deviation between expected and measured cumulative dose was calculated for each detector for each fraction, and averaged over each patient and the patient population as a whole. Results: The average difference between expected dose and measured dose ranged from -3.3% to 3.3% for individual patients, with standard deviations between 5.6% and 7.1% for four of the patients. The average difference for the entire population was -0.4% with a standard deviation of 2.8%. The detectors were well tolerated by the patients and the system did not interrupt the clinical workflow. Conclusion: PSDs perform well as in vivo dosimeters, exhibiting good accuracy and precision. This, combined with the practicability of using such a system, positions the PSD as a strong candidate for clinical in vivo dosimetry in the future. This work supported in part by the National Cancer Institute through an R01 grant (CA120198-01A2) and by the American Legion Auxiliary through the American Auxiliary Fellowship in Cancer Research.

60 APPLIED LIFE SCIENCES↗

Sci—Thur AM: YIS - 11: Estimation of Bladder-Wall Cumulative Dose in Multi-Fraction Image-Based Gynaecological Brachytherapy Using Deformable Point Set Registration

Dosimetric parameters based on dose-volume histograms (DVH) of contoured structures are routinely used to evaluate dose delivered to target structures and organs at risk. However, the DVH provides no information on the spatial distribution of the dose in situations of repeated fractions with changes in organ shape or size. The aim of this research was to develop methods to more accurately determine geometrically localized, cumulative dose to the bladder wall in intracavitary brachytherapy for cervical cancer. The CT scans and treatment plans of 20 cervical cancer patients were used. Each patient was treated with five high-dose-rate (HDR) brachytherapy fractions of 600cGy prescribed dose. The bladder inner and outer surfaces were delineated using MIM Maestro software (MIM Software Inc.) and were imported into MATLAB (MathWorks) as 3-dimensional point clouds constituting the “bladder wall”. A point-set registration toolbox for MATLAB, Coherent Point Drift (CPD), was used to non-rigidly transform the bladder-wall points from four of the fractions to the coordinate system of the remaining (reference) fraction, which was chosen to be the emptiest bladder for each patient. The doses were accumulated on the reference fraction and new cumulative dosimetric parameters were calculated. The LENT-SOMA toxicity scores of these patients were studied against the cumulative dose parameters. Based on this study, there was no significant correlation between the toxicity scores and the determined cumulative dose parameters.

60 APPLIED LIFE SCIENCES↗

Beamlet based direct aperture optimization for MERT using a photon MLC

Purpose: A beamlet based direct aperture optimization (DAO) for modulated electron radiotherapy (MERT) using photon multileaf collimator (pMLC) shaped electron fields is developed and investigated. Methods: The Swiss Monte Carlo Plan (SMCP) allows the calculation of dose distributions for pMLC shaped electron beams. SMCP is interfaced with the Eclipse TPS (Varian Medical Systems, Palo Alto, CA) which can thus be included into the inverse treatment planning process for MERT. This process starts with the import of a CT-scan into Eclipse, the contouring of the target and the organs at risk (OARs), and the choice of the initial electron beam directions. For each electron beam, the number of apertures, their energy, and initial shape are defined. Furthermore, the DAO requires dose–volume constraints for the structures contoured. In order to carry out the DAO efficiently, the initial electron beams are divided into a grid of beamlets. For each of those, the dose distribution is precalculated using a modified electron beam model, resulting in a dose list for each beamlet and energy. Then the DAO is carried out, leading to a set of optimal apertures and corresponding weights. These optimal apertures are now converted into pMLC shaped segments and the dose calculation for each segment is performed. For these dose distributions, a weight optimization process is launched in order to minimize the differences between the dose distribution using the optimal apertures and the pMLC segments. Finally, a deliverable dose distribution for the MERT plan is obtained and loaded back into Eclipse for evaluation. For an idealized water phantom geometry, a MERT treatment plan is created and compared to the plan obtained using a previously developed forward planning strategy. Further, MERT treatment plans for three clinical situations (breast, chest wall, and parotid metastasis of a squamous cell skin carcinoma) are created using the developed inverse planning strategy. The MERT plans are compared to clinical standard treatment plans using photon beams and the differences between the optimal and the deliverable dose distributions are determined. Results: For the idealized water phantom geometry, the inversely optimized MERT plan is able to obtain the same PTV coverage, but with an improved OAR sparing compared to the forwardly optimized plan. Regarding the right-sided breast case, the MERT plan is able to reduce the lung volume receiving more than 30% of the prescribed dose and the mean lung dose compared to the standard plan. However, the standard plan leads to a better homogeneity within the CTV. The results for the left-sided thorax wall are similar but also the dose to the heart is reduced comparing MERT to the standard treatment plan. For the parotid case, MERT leads to lower doses for almost all OARs but to a less homogeneous dose distribution for the PTV when compared to a standard plan. For all cases, the weight optimization successfully minimized the differences between the optimal and the deliverable dose distribution. Conclusions: A beamlet based DAO using multiple beam angles is implemented and successfully tested for an idealized water phantom geometry and clinical situations.

60 APPLIED LIFE SCIENCES↗

The evaluation of a 2D diode array in “magic phantom” for use in high dose rate brachytherapy pretreatment quality assurance

Purpose: High dose rate (HDR) brachytherapy is a treatment method that is used increasingly worldwide. The development of a sound quality assurance program for the verification of treatment deliveries can be challenging due to the high source activity utilized and the need for precise measurements of dwell positions and times. This paper describes the application of a novel phantom, based on a 2D 11 × 11 diode array detection system, named “magic phantom” (MPh), to accurately measure plan dwell positions and times, compare them directly to the treatment plan, determine errors in treatment delivery, and calculate absorbed dose. Methods: The magic phantom system was CT scanned and a 20 catheter plan was generated to simulate a nonspecific treatment scenario. This plan was delivered to the MPh and, using a custom developed software suite, the dwell positions and times were measured and compared to the plan. The original plan was also modified, with changes not disclosed to the primary authors, and measured again using the device and software to determine the modifications. A new metric, the “position–time gamma index,” was developed to quantify the quality of a treatment delivery when compared to the treatment plan. The MPh was evaluated to determine the minimum measurable dwell time and step size. The incorporation of the TG-43U1 formalism directly into the software allows for dose calculations to be made based on the measured plan. The estimated dose distributions calculated by the software were compared to the treatment plan and to calibrated EBT3 film, using the 2D gamma analysis method. Results: For the original plan, the magic phantom system was capable of measuring all dwell points and dwell times and the majority were found to be within 0.93 mm and 0.25 s, respectively, from the plan. By measuring the altered plan and comparing it to the unmodified treatment plan, the use of the position–time gamma index showed that all modifications made could be readily detected. The MPh was able to measure dwell times down to 0.067 ± 0.001 s and planned dwell positions separated by 1 mm. The dose calculation carried out by the MPh software was found to be in agreement with values calculated by the treatment planning system within 0.75%. Using the 2D gamma index, the dose map of the MPh plane and measured EBT3 were found to have a pass rate of over 95% when compared to the original plan. Conclusions: The application of this magic phantom quality assurance system to HDR brachytherapy has demonstrated promising ability to perform the verification of treatment plans, based upon the measured dwell positions and times. The introduction of the quantitative position–time gamma index allows for direct comparison of measured parameters against the plan and could be used prior to patient treatment to ensure accurate delivery.

60 APPLIED LIFE SCIENCES↗

Computer-aided pulmonary image analysis in small animal models

Purpose: To develop an automated pulmonary image analysis framework for infectious lung diseases in small animal models. Methods: The authors describe a novel pathological lung and airway segmentation method for small animals. The proposed framework includes identification of abnormal imaging patterns pertaining to infectious lung diseases. First, the authors’ system estimates an expected lung volume by utilizing a regression function between total lung capacity and approximated rib cage volume. A significant difference between the expected lung volume and the initial lung segmentation indicates the presence of severe pathology, and invokes a machine learning based abnormal imaging pattern detection system next. The final stage of the proposed framework is the automatic extraction of airway tree for which new affinity relationships within the fuzzy connectedness image segmentation framework are proposed by combining Hessian and gray-scale morphological reconstruction filters. Results: 133 CT scans were collected from four different studies encompassing a wide spectrum of pulmonary abnormalities pertaining to two commonly used small animal models (ferret and rabbit). Sensitivity and specificity were greater than 90% for pathological lung segmentation (average dice similarity coefficient > 0.9). While qualitative visual assessments of airway tree extraction were performed by the participating expert radiologists, for quantitative evaluation the authors validated the proposed airway extraction method by using publicly available EXACT’09 data set. Conclusions: The authors developed a comprehensive computer-aided pulmonary image analysis framework for preclinical research applications. The proposed framework consists of automatic pathological lung segmentation and accurate airway tree extraction. The framework has high sensitivity and specificity; therefore, it can contribute advances in preclinical research in pulmonary diseases.

60 APPLIED LIFE SCIENCES↗

SU-C-213-02: Characterizing 3D Printing in the Fabrication of Variable Density Phantoms

Purpose: In this work, we present characterization, process flow, quality control and application of 3D fabricated low density phantoms for radiotherapy quality assurance. Methods: A Rostock delta 3D printer using polystyrene filament of diameter 1.75 mm was used to print geometric volumes of 2×2×1 cm{sup 3} of varying densities. The variable densities of 0.1 to 0.75 g/cm {sup 3} were created by modulating the infill. A computed tomography (CT) scan was performed to establish an infill-density calibration curve as well as characterize the quality of the print such as uniformity and the infill pattern. The time required to print these volumes was also recorded. Using the calibration, two low density cones (0.19, 0.52 g/cm{sup 3}) were printed and benchmarked against commercially available phantoms. The dosimetric validation of the low density scaling of Anisotropic Analytical Algorithm (AAA) was performed by using a 0.5 g/cm{sup 3} slab of 10×10×2.4 cm{sup 3} with EBT3 GafChromic film. The gamma analysis at 3%/3mm criteria were compared for the measured and computed dose planes. Results: Analysis of the volume of air pockets in the infill resulted in a reasonable uniformity for densities 0.4 to 0.75 g/cm{sup 3}. Printed phantoms with densities below 0.4 g/cm{sup 3} exhibited a higher ratio of air to polystyrene resulting in large non-uniformity. Compared to the commercial inserts, good agreement was observed only for the printed 0.52 g/cm{sup 3} cone. Dosimetric comparison for a printed low density volume placed in-between layers of solid water resulted in >95% gamma agreement between AAA calculated dose planes and measured EBT3 films for a 6MV 5×5 cm{sup 2} clinical beam. The comparison showed disagreement in the penumbra region. Conclusion: In conclusion, 3D printing technology opens the door to desktop fabrication of variable density phantoms at economical prices in an efficient manner for the quality assurance needs of a small clinic.

60 APPLIED LIFE SCIENCES↗

SU-C-BRB-03: Novel Technique to Implement GRID Therapy in a Commercial Treatment Planning System

Purpose: Due to the difficulty of creating an accurate multi-aperture block in treatment planning systems (TPS), spatially fractionated radiation therapy (GRID Therapy) is limited to clinical setups using simple monitor unit calculations. In this work, we present a novel approach to accurately model a grid block in a TPS and evaluate its dosimetric accuracy. Methods: An acrylic GRID block was fashioned such that the hole size and spacing were the same dimensions of the brass GRID block (dotDecimal) at isocenter. Holes were non-divergent and drilled 1 cm deep. CT scans (RT Lightspeed, GE Healthcare) of the block were acquired using axial slices with a thickness of 0.625 mm. These were imported into Eclipse (version 11, Varian Medical Systems) and holes were auto-contoured into structures. The GRID block was created in Eclipse by forming apertures around the hole structures using a simple three step process. Treatment plans were created in a water-equivalent phantom using 6 and 10 MV beams, delivered with a linear accelerator (Clinac iX, Varian Medical Systems) and measured using a water tank, film and a diode array. Results: Comparisons of percent depth dose curves and profiles at depths of maximum dose, 5cm, and 10cm for field sizes ranging from 5 cm{sup 2} to 25 cm{sup 2} using water and film were within 3% of their respective positions in Eclipse. GRID plans utilizing various jaw sizes and MLC blocking measured with film and a diode array showed pass rates with an average of 97% using Gamma analysis at 3%/ 3 mm and no lower than 93%. Conclusion: We have developed a simple yet accurate method of incorporating a GRID block into a commercially available TPS and demonstrated that the TPS accurately reflects the dose delivered. This will allow for real-time planning using patient scans and encourage new methods for GRID therapy. Support provided by dotDecimal, Sanford, FL.

60 APPLIED LIFE SCIENCES↗

SU-C-BRA-04: Use of Esophageal Wall Thickness in Evaluation of the Response to Chemoradiation Therapy for Esophageal Cancer

Purpose: To quantitatively evaluate the esophageal cancer response to chemoradiation therapy (CRT) by measuring the esophageal wall thickness in CT. Method: Two datasets were used in this study. The first dataset is composed of CT scans of 15 esophageal cancer patients and 15 normal controls. The second dataset is composed of 20 esophageal cancer patients who underwent PET/CT scans before (Pre-CRT) and after CRT (Post-CRT). We first segmented the esophagus using a multi-atlas-based algorithm. The esophageal wall thickness was then computed, on each slice, as the equivalent circle radius of the segmented esophagus excluding the lumen. To evaluate the changes of wall thickness, we computed the standard deviation (SD), coefficient of variation (COV, SD/Mean), and flatness [(Max–Min)/Mean] of wall thickness along the entire esophagus. Results: For the first dataset, the mean wall thickness of cancer patients and normal controls were 6.35 mm and 6.03 mm, respectively. The mean SD, COV, and flatness of the wall thickness were 2.59, 0.21, and 1.27 for the cancer patients and 1.99, 0.16, and 1.13 for normal controls. Statistically significant differences (p < 0.05) were identified in SD and flatness. For the second dataset, the mean wall thickness of pre-CRT and post-CRT patients was 7.13 mm and 6.84 mm, respectively. The mean SD, COV, and flatness were 1.81, 0.26, and 1.06 for pre-CRT and 1.69, 0.26, and 1.06 for post-CRT. Statistically significant difference was not identified for these measurements. Current results are based on the entire esophagus. We believe significant differences between pre- and post-CRT scans could be obtained, if we conduct the measurements at tumor sites. Conclusion: Results show thicker wall thickness in pre-CRT scans and differences in wall thickness changes between normal and abnormal esophagus. This demonstrated the potential of esophageal wall thickness as a marker in the tumor CRT response evaluation. This work was supported in part by the National Cancer Institute Grant R01CA172638.

60 APPLIED LIFE SCIENCES↗

SU-C-210-03: Impact of Breathing Irregularities On Gated Treatments

Purpose: To evaluate the effect of breathing irregularities on target location in gated treatments using amplitude and phase gating. Methods: 111 breathing patterns acquired using RPM system were categorized based on period and amplitude STD as regular (STD period ≤ 0.5 s, STD amplitude ≤ 1.5 mm), medium (0.5 s < STD period ≤ 1 s, 1.5 mm < STD amplitude ≤ 3 mm) and irregular (STD period > 1 s, STD amplitude > 3 mm). One pattern representative of the average defined population was selected per category and corresponding target motion reproduced using Quasar Respiratory Motion Phantom. Phantom in motion underwent 4D-CT scan with phase reconstruction. Gated window was defined at end of exhale and DRRs reconstructed in treatment planning at 40% (beam on) and 60% phase (beam off). Target location uncertainty was assessed by comparing gated kV triggered images continuously acquired at beam on/off on a True Beam 2.0 with corresponding DRRs. Results: Average target uncertainty with amplitude gating was in [0.4 – 1.9] mm range for the different scenarios with maximum STD of 1.2 mm for the irregular pattern. Average target uncertainty with phase gating was [1.1 – 2.2] mm for regular and medium patterns, while it increased to [3.6 – 9.6] mm for the irregular pattern. Live gated motion was stable with amplitude gating, while increasing with phase gating for the irregular pattern. Treatment duration range was [68 – 160] s with amplitude and [70 – 74] s with phase gating. Conclusion: Breathing irregularities were found to affect gated treatments only when using phase gating. For regular and medium patterns no significant difference was found between the two gating strategies. Amplitude gating ensured stable gated motion within the different patterns, thus reducing intra-fraction target location variability for the irregular pattern and resulting in longer treatment duration.

60 APPLIED LIFE SCIENCES↗

SU-E-J-73: Extension of a Clinical OIS/EMR/R&V System to Deliver Safe and Efficient Adaptive Plan-Of-The-Day Treatments Using a Fully Customizable Plan-Library-Based Workflow

Purpose: To extend a clinical Record and Verify (R&V) system to enable a safe and fast workflow for Plan-of-the-Day (PotD) adaptive treatments based on patient-specific plan libraries. Methods: Plan libraries for PotD adaptive treatments contain for each patient several pre-treatment generated treatment plans. They may be generated for various patient anatomies or CTV-PTV margins. For each fraction, a Cone Beam CT scan is acquired to support the selection of the plan that best fits the patient’s anatomy-of-the-day. To date, there are no commercial R&V systems that support PotD delivery strategies. Consequently, the clinical workflow requires many manual interventions. Moreover, multiple scheduled plans have a high risk of excessive dose delivery. In this work we extended a commercial R&V system (MOSAIQ) to support PotD workflows using IQ-scripting. The PotD workflow was designed after extensive risk analysis of the manual procedure, and all identified risks were incorporated as logical checks. Results: All manual PotD activities were automated. The workflow first identifies if the patient is scheduled for PotD, then performs safety checks, and continues to treatment plan selection only if no issues were found. The user selects the plan to deliver from a list of candidate plans. After plan selection, the workflow makes the treatment fields of the selected plan available for delivery by adding them to the treatment calendar. Finally, control is returned to the R&V system to commence treatment. Additional logic was added to incorporate off-line changes such as updating the plan library. After extensive testing including treatment fraction interrupts and plan-library updates during the treatment course, the workflow is running successfully in a clinical pilot, in which 35 patients have been treated since October 2014. Conclusion: We have extended a commercial R&V system for improved safety and efficiency in library-based adaptive strategies enabling a wide-spread implementation of those strategies. This work was in part funded by a research grant of Elekta AB, Stockholm, Sweden.

60 APPLIED LIFE SCIENCES↗