Search NASA⌕ Search

SEARCH · Search NASA

Results for “Circulating Water System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Can general circulation models (GCMs) represent cloud liquid water path adjustments to aerosol–cloud interactions?

Abstract. General circulation models (GCMs), unlike other lines of evidence, indicate that anthropogenic aerosols cause a global-mean increase in cloud liquid water path (ℒ) and thus a negative adjustment to radiative forcing of the climate by aerosol–cloud interactions. In part 1 of this series of papers, we showed that this is true even in models that reproduce the negative correlation observed in present-day internal variability in ℒ and cloud droplet number concentration (Nd). We studied several possible confounding mechanisms that could explain the noncausal cloud–aerosol correlations in GCMs and that possibly contaminate observational estimates of radiative adjustments. Here, we perform single-column and full-atmosphere GCM experiments to investigate the causal model-physics mechanisms underlying the model radiative adjustment estimate. We find that both aerosol–cloud interaction mechanisms thought to be operating in real clouds – precipitation suppression and entrainment evaporation enhancement – are active in GCMs and behave qualitatively in agreement with physical process understanding. However, the modeled entrainment enhancement has a negligible global-mean effect. This raises the question of whether the GCM estimate is incorrect due to parametric or base-state representation errors or whether the process understanding gleaned from a limited set of canonical cloud cases is insufficiently representative of the diversity of clouds in the real climate. Regardless, even at limited resolution, the GCM physics appears able to parameterize the small-scale microphysics–turbulence interplay responsible for the entrainment enhancement mechanism. We suggest ways to resolve tension between current and future (storm-resolving) global modeling systems and other lines of evidence in synthesis climate projections.

54 ENVIRONMENTAL SCIENCES↗

Amphibian fertilization and development in microgravity

During the year before launch, female frogs will be tested every 3 months for the quantity and quality of eggs produced. Two weeks or more prior to launch, male and female frogs will be transported to the John F. Kennedy Space Center (KSC). During the few weeks before launch, groups will be periodically tested for egg quality to assure that the frogs have adapted to the KSC laboratory environment. About 27 hours before launch, four females will be placed in a damp foam-lined box, called the Adult Frog Box (AFB), through which 100 cc/min of air wil be circulated. The AFB will be lowered into the Spacelab and loaded into the Frog Environmental Unit (FEU) during the final pre-launch preparations. A sperm suspension, for use in flight to fertilize the eggs, will also be prepared and loaded during the pre-launch period. The sperm suspension, together with a kit of syringes containing Human Chorionic Gonadotropin (HCG), will be stored in a refrigerator aboard the shuttle until needed in flight. On the first day of flight, the AFB will be transferred from the FEU to the General Purpose Work Station (GPWS), which is a type of glove box specially designed to allow the crew to use chemicals and biological materials during the flight without contaminating the shuttle/Spacelab environment. Inside the GPWS the four adult frogs will be injected with the HCG hormone and returned to the FEU. Approximately 16 hours after injection, ovulation should have taken place and 15 to 20 eggs from each frog will be placed on each of two egg baskets and covered with sperm for 10 minutes. The egg baskets are inserted into acrylic egg chambers and 50 ml of 'pond water' (20 percent strength Modified Ringers solution (is added. One of the chambers from each frog will be placed on a centrifuge within the FEU and rotated to simulate normal terrestrial gravity (1 g). The remaining chambers are incubated under microgravity conditions within the FEU. Forty minutes after fertilization, the four chambers exposed to 1 g will be removed and observed within the GPWS using a dissecting microscope and camera system. On the basis of egg rotation and egg appearance, the 'best' and 'second best' frogs will be selected to contribute additional eggs. Using the two best frogs, 22 egg chambers will be loaded with eggs and fertilized. Eleven chambers wil be incubated at microgravity and eleven will be incubated on the centrifuge. At various times during the flight, chambers will be removed from the FEU and transferred to the GPWS where a formaldehyde-based fixative will be injected in order to preserve important developmental stages for in depth study following the flight. Five of the 22 chambers plus the eight fertilization test chambers will be returned to Earth with live tadpoles. The swimming behavior of these free swimming tadpoles will be examined within several hours of landing and some will be fixed for a detailed analysis of their inner ear, the otolity, the animals 'balance system.' Lychakov and Vinikov reported an increase in otolith size in tadpoles that developed (but were not fertilized) in space. Live tadpoles from the SL-J flight will be raised through metamorphsis for studies of maturation including an analysis of the effects of space flight on their ability to produce normal progency. Following the flight, the fixed embryos will be serially sectioned and stained using procedures that were developed for this experiment. The embroys fixed at the 2-4 cell stage will be examined for the distribution of cytoplasmic contents, including the various classes of yolk platelets, and the location and shape of the cleavage furrows. The gastrulae will be assessed for the normality of the complex cellular rearrangements that constitute blastopore formation and involution, i.e., the differentiation of the embryo into its specialized body parts. Using a new procedure, the gastrulae will be bleached which will enable the initial sperm entry point (SEP) to be located. The correlation between the SEP and the dorsal lip of the blastopore will be determined. Under normal terrestrial conditions it was shown that the SEP typically is located on the side of the egg opposite the future dorsal side of the embryo. The neurulae will be examined for the normality and completeness of the neural plate and archenteron expansion. The tadpole stages will be used to study the allometry and morphology of the various organ systems.

Souza, Kenneth A.↗

Sensitivity to Glacial Forcing in the CCSM4

Findings are introduced from the Community Climate System Model, version 4 (CCSM4), simulation of the Last Glacial Maximum (LGM) from phase 5 of the Coupled Model Intercomparison Project (CMIP5) at the standard 1° resolution, the same resolution as the majority of the CCSM4 CMIP5 long-term simulations for the historical and future projection scenarios. The forcings and boundary conditions for this simulation follow the protocols of the Paleoclimate Modeling Intercomparison Project, version 3 (PMIP3). Two additional CCSM4 CO 2 sensitivity simulations, in which the concentrations are abruptly changed at the start of the simulation to the low 185 ppm LGM concentrations (LGMCO2) and to a quadrupling of the preindustrial concentration (4×CO 2 ), are also analyzed. For the full LGM simulation, the estimated equilibrium cooling of the global mean annual surface temperature is 5.5°C with an estimated radiative forcing of -6.2 W m -2 . The radiative forcing includes the effects of the reduced LGM greenhouse gases, ice sheets, continental distribution with sea level lowered by approximately 120 m from the present, and orbital parameters, but not changes to atmospheric aerosols or vegetation biogeography. The LGM simulation has an equilibrium climate sensitivity (ECS) of 3.1(±0.3)°C, comparable to the CCSM4 4×CO 2 result. The LGMCO 2 simulation shows a greater ECS of 4.2°C. Other responses found at the LGM in CCSM4 include a global precipitation rate decrease at a rate of ~2% °C -1 , similar to climate change simulations in the Intergovernmental Panel on Climate Change Fourth Assessment Report (IPCC AR4); a strengthening of the Atlantic meridional overturning circulation (AMOC) with a shoaling of North Atlantic Deep Water and a filling of the deep basin up to sill depth with Antarctic Bottom Water; and an enhanced seasonal cycle accompanied by reduced ENSO variability in the eastern Pacific Ocean’s SSTs.

54 ENVIRONMENTAL SCIENCES↗

Assessing shellfish water exposure to fecal bacteria pollution in Salish Sea: three-dimensional modeling and implications for monitoring

Fecal bacteria (FB) contamination poses significant risks to shellfish safety and management in coastal and estuarine waters. Despite extensive pollution identification and correction efforts, FB contamination in shellfish-growing areas persists in the Salish Sea, highlighting the need to identify overlooked sources and better understand FB transport from riverine and shoreline inputs to shellfish beds. To address this, a high-resolution three-dimensional hydrodynamic model coupled with FB kinetics was developed and applied to a case study site in Salish Sea—Portage Bay—to simulate freshwater plume circulation, flushing dynamics, and bacterial transport. Daily FB loading from the major freshwater inflow—Nooksack River was generated by both linear interpolation and integrating a machine learning approach (XGBoost), trained on historical hydrological and meteorological data. The model successfully reproduced both the magnitude and seasonal variation of FB concentrations in Portage Bay for the year of 2021, demonstrating that simplified FB kinetics with first-order decay due to mortality was effective in this dynamic coastal environment with short flushing time. Model results identified the Nooksack River as the dominant far-field FB source, while scenario simulations showed that near-field coastal stormwater outfalls elevated local FB levels following rainfall, particularly under low-flow conditions. The XGBoost prediction provided comparable or superior accuracy to linear interpolation, particularly during periods of missing observational data, by capturing short-term variability and event-driven loading more effectively. Integrating data-driven riverine FB inputs with mechanistic coastal numerical modeling provides a robust framework for operational forecasting of shellfish bed exposure risk and supports adaptive monitoring and management of shellfish growing areas in the Salish Sea and similar coastal systems.

Salish Sea↗

Report on Year-4 of Water NSTF Matrix Testing: Facility Maintenance and Accident Testing

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report serves as a summary of maintenance and experimental activities during the program’s fourth year of water-based operation. A planned six-month maintenance period began in August 2021, during which major inspections, repairs, cleaning, and installation of new instrumentation and data acquisition hardware were conducted. Most significantly, two heaters that faulted during Year-3 were repaired, allowing the facility to resume use of the full heated section area and full range of available electric power. The remainder of the year consisted of eight months of test operations, during which the facility logged 211 hours of active heating across one bake-out (following the maintenance period) and seven matrix tests; five classifieds as Accepted per NQA-1, one as Trending, and one as Failed. Testing began by performing two repeat cases to confirm expected facility response and behavior during both single- and two-phase flow conditions, ensuring no changes were introduced during the maintenance period that might have altered the thermal-hydraulic characteristics of the facility. In continuation of the power parametric series initiated in previous years, a high-power test case was then performed examining heat removal performance at a decay heat load equivalent to 2.4 MWt, full-scale, a level exceeding maximum design targets. Additional testing then introduced various blockage scenarios along the network piping, examining the effects of partial and complete blockages of the flow paths on the system behavior and heat removal performance. A study of static boiling tests directed at understanding the geysering two-phase instability was also conducted. The loop was filled only to the bottom of the tank outlet, creating an open loop configuration that prevents any natural circulation flow from occurring, and the heaters were powered on until the facility reached saturation conditions. Following, a series of quasi-steady-state conditions were introduced by adjusting the inventory level in the adiabatic chimney piping at decreasingly lower elevations above the heated region. A strong correlation of geysering characteristics and loop level was observed, with flow and temperature excursions decreasing in intensity, but increasing in frequency, as the fill were reduced to lower elevations along the chimney piping. Once the level fell very low in the chimney, at points near the top of the heated section, the system reached a stable state of continuous boiling without any occurrence of geysering eruptions. A final significant testing accomplishment this year was successful completion of an “accident scenario” test, whose operating conditions were based on a prototypic decay heat curve provided by Framatome and scaled for the NSTF. This test began by establishing steady-state, single-phase “normal operation” conditions, before simulating an accident trip where the availability of active cooling systems was lost. Loop temperatures gradually increased until reaching saturation and subsequent two-phase boiling flow. Over the course of an extended operational period along the defined decay heat curve, steam boil-off caused gradual but continued depletion of liquid inventory until reaching a critically low level causing flow stagnation and cessation of natural circulation heat removal. At this point, after nearly 72 hours of continuous operation, a cold refill was performed to replenish the system inventory and allow the facility to re-establish closed loop natural circulation flow and return to a safe operational state.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simulation of DWPF Chemical Process Cell Using a Reaction Calorimeter

The Defense Waste Processing Facility (DWPF) converts liquid radioactive waste into glass using a Sludge Receipt Adjustment Tank (SRAT) and Slurry Mix Evaporator (SME) in addition to other processes. The SRAT and SME processes can be simulated on a small-scale using the Mettler-Toledo Reaction Calorimeter (RC1). This equipment is able to automate the execution and monitoring of experiments involving nonradioactive chemical simulants. During the chemical processing of sludge in the SRAT process, foam begins to form and can foam over the reaction vessel. The current antifoam used at DWPF creates a risk of increased flammability and has a limited pH range. Usually, mercury is circulated back into the reaction vessel during the SRAT process, making it difficult to remove. To combat foam over, novel antifoams will be tested during the boil-up process using the RC1. To improve mercury extraction, 3D-printed coalescer columns will be tested within the Mercury Water Wash Tank (MWWT) of the RC1. Testing of Simulant Sludge Batch 6 (SB6) was performed to ensure: the sludge would form a stable foam at boiling during full SRAT/SME runs; the antifoam would reduce the amount of foam within the vessel The sludge and a Precipitate Reactor Feed Tank (PRFT) simulant with monosodium titanate (MST) were mixed separately, combined, and then heated to boiling. As shown below, the antifoam used was able to eliminate the foam within the vessel, as expected. The FormLabs Form2 3D Printer can be used to create roughly 3-inch tall and 1-inch diameter columns from clear and ceramic resins. The columns will utilize chemical and physical forces to draw the mercury out of a condensed offgas stream leaving the RC1 reaction vessel. These columns will be tested during full SRAT/SME runs on the basis of how well they are able to collect elemental mercury. In preparation for full-scale runs, the RC1 equipment was assembled onto a custom table and tested with water runs. The software used to control automation, iControl, has a user-friendly interface that allows the experiment to be altered as needed. An example of the data recorded during an experimental run is represented in Figure 1 below. Water runs were utilized as a way to prove if the RC1 system was functioning in the following areas: Boil-up rates, Chemical additions using pumps, Temperature readings, Balance readings, Probe readings, Offgas system, Agitation. Future Plans: Five novel antifoams will be tested during full SRAT/SME runs. The most effective antifoam will be utilized in DWPF's Chemical Process Cell. The design of the Mercury Extraction Coalescer can be further manipulated to increase the extraction of not only elemental mercury, but other heavy metals in environmental remediation processes as well.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dual Rate Adaptive Control for an Industrial Heat Supply Process Using Signal Compensation Approach

The industrial heat supply process (HSP) is a highly nonlinear cascaded process which uses a steam valve opening as its control input, the steam flow-rate as its inner loop output and the supply water temperature as its outer loop output. The relationship between the heat exchange rate and the model parameters, such as steam density, entropy, and fouling correction factor and heat exchange efficiency are unknown and nonlinear. Moreover, these model parameters vary in line with steam pressure, ambient temperature and the residuals caused by the quality variations of the circulation water. When the steam pressure and the ambient temperature are of high values and are subjected to frequent external random disturbances, the supply water temperature and the steam flow-rate would interact with each other and fluctuate a lot. This is also true when the process exhibits unknown characteristic variations of the process dynamics caused by the unexpected changes of the heat exchange residuals. As a result, it is difficult to control the supply water temperature and the rates of changes of steam flow-rate well inside their targeted ranges. In this paper, a novel compensation signal based dual rate adaptive controller is developed by representing the unknown variations of dynamics as unmodeled dynamics. In the proposed controller design, such a compensation signal is constructed and added onto the control signal obtained from the linear deterministic model based feedback control design. Such a compensation signal aims at eliminating the unmodeled dynamics and the rate of changes of the currently sample unmodeled dynamics. A successful industrial application is carried out, where it has been shown that both the supply water temperature and the rate of the changes of the steam flow-rate can be controlled well inside their targeted ranges when the process is subjected to unknown variations of its dynamics.

Adaptive signal approacg↗

Low-frequency variations in the atmospheric branch of the global hydrological cycle

The annual variation of the hydrological cycle is illustrated in terms of hemispheric-mean hydrological variables for the Northern and Southern Hemispheres, while the intraseasonal variations of the global hydrological cycle are illustrated with mean values over two hemispheres that form an east-west partition of the globe. This partition is defined by the 60 deg E-120 deg W great circle and was chosen so that the mean precipitation difference and the divergent water vapor transport between the two hemispheres was maximized. Two years (1979-80) of daily precipitation estimates from the Goddard Laboratory for Atmospheres an 14 years (1979-92) of upper-air data generated by the Global Data Assimilation System at the National Meteorological Center are used in making quantitative estimates of the annual and intraseasonal variations in the global hydrological cycle. The annual variations in hemispheric-mean precipitation (P-circumflex) and water vapor flux divergence (del(vector differential operator) dot Q-circumflex) for the Northern and Southern Hemispheres are comparable with amplitudes of about 0.5 approximately 0.7 mm/day. Both (P-circumflex) and (del(vector differential operator) dot Q-circumflex) vary annually in a coherent way in each hemisphere so that water vapor diverges from the winter hemisphere, where (P-circumflex) reaches its minimum, to the summer hemisphere, where (P-circumflex) attains its maximum. In fact, the hemispheric-mean divergence of water vapor flux changes sign during the annual cycle. Intraseasonal variations of hemispheric-mean precipitation mean P-tilde, evaporation mean E-tilde, and water vapor flux divergence mean del (vector differential operator) dot Q-tilde in the two hemisphres in the east-west direction are comparable with amplitudes of about 0.1 approximately 0.2 mm/day, although amplitudes in some cases exceed 0.3 mm/day. Hemispheric-mean precipitation mean P-tilde varies coherently in opposite phase for the two hemispheres, while mean del (vector differential operator) dot Q-tilde varies so that water vapor diverges from the hemisphere of maximum mean P-tilde to the hemisphere to the hemisphere of minimum mean P-tilde. Intraseasonal variations of mean P-tilde, mean E-tilde, and mean del (vector differential oprator) dot Q-tilde are in accord with the eastward propagation of the intraseasonal global divergent circulation.

Chen, Tsing-Chang↗

Improving Reanalyses Using TRMM and SSM/I-Derived Precipitation and Total Precipitable Water Observations

Global reanalyses currently contain significant errors in the primary fields of the hydrological cycle such as precipitation, evaporation, moisture, and the related cloud fields, especially in the tropics. The Data Assimilation Office (DAO) at the NASA Goddard Space Flight Center has been exploring the use of rainfall and total precipitable water (TPW) observations from the Tropical Rainfall Measuring Mission (TRMM) Microwave Imager (TMI) and the Special Sensor Microwave/ Imager (SSM/I) instruments to improve these fields in reanalyses. The DAO has developed a "1+1"D procedure to assimilate 6-hr averaged rainfall and TPW into the Goddard Earth Observing System (GEOS) Data Assimilation System (DAS). The algorithm is based on a 6-hr time integration of a column version of the GEOS DAS. The "1+1" designation refers to one spatial dimension plus one temporal dimension. The scheme minimizes the least-square differences between the satellite-retrieved rain rates and those produced by the column model over the 6-hr analysis window. The control variables are analysis increments of moisture within the Incremental Analysis Update (IAU) framework of the GEOS DAS. This 1+1D scheme, in its generalization to four dimensions, is related to the standard 4D variational assimilation but differs in its choice of the control variable. Instead of estimating the initial condition at the beginning of the assimilation cycle, it estimates the constant IAU forcing applied over a 6-hr assimilation cycle. In doing so, it imposes the forecast model as a weak constraint in a manner similar to the variational continuous assimilation techniques. We present results from an experiment in which the observed rain rate and TPW are assumed to be "perfect". They show that assimilating the TMI and SSM/I-derived surface precipitation and TPW observations improves not only the precipitation and moisture fields but also key climate parameters directly linked to convective activities such as clouds, the outgoing longwave radiation, and the large-scale circulation in the tropics. In particular, assimilating these data types reduce the state-dependent systematic errors in the assimilated products. The improved analysis also leads to a better short-range forecast, but the impact is modest compared with improvements in the time-averaged fields. These results suggest that, in the presence of biases and other errors of the forecast model, it is possible to improve the time-averaged "climate content" in the assimilated data without comparable improvements in the short-range forecast skill. Results of this experiment provide a useful benchmark for evaluating error covariance models for optimal use of these data types.

Hou, Arthur Y.↗

PERFORMANCE ANALYSIS OF MECHANICAL DRAFT COOLING TOWER

Industrial processes use mechanical draft cooling towers (MDCT's) to dissipate waste heat by transferring heat from water to air via evaporative cooling, which causes air humidification. The Savannah River Site (SRS) has cross-flow and counter-current MDCT's consisting of four independent compartments called cells. Each cell has its own fan to help maximize heat transfer between ambient air and circulated water. The primary objective of the work is to simulate the cooling tower performance for the counter-current cooling tower and to conduct a parametric study under different fan speeds and ambient air conditions. The Savannah River National Laboratory (SRNL) developed a computational fluid dynamics (CFD) model and performed the benchmarking analysis against the integral measurement results to accomplish the objective. The model uses three-dimensional steady-state momentum, continuity equations, air-vapor species balance equation, and two-equation turbulence as the basic governing equations. It was assumed that vapor phase is always transported by the continuous air phase with no slip velocity. In this case, water droplet component was considered as discrete phase for the interfacial heat and mass transfer via Lagrangian approach. Thus, the air-vapor mixture model with discrete water droplet phase is used for the analysis. A series of parametric calculations was performed to investigate the impact of wind speeds and ambient conditions on the thermal performance of the cooling tower when fans were operating and when they were turned off. The model was also benchmarked against the literature data and the SRS integral test results for key parameters such as air temperature and humidity at the tower exit and water temperature for given ambient conditions. Detailed results will be published here.

42 ENGINEERING↗

Explicit quantification of residence and flushing times in the Salish Sea using a sub-basin scale shoreline resolving model

The Salish Sea, located in the Pacific Northwest region of North America has complex currents and circulation features distributed over numerous interconnected deep basins with islands. Increased risk of exposure to oil spills and untreated wastewater from maritime emergencies and treatment plant failures have led to a need for quantifying residence and flushing characteristics at a sub-basin scale using a shoreline resolving hydrodynamic model. An unstructured grid model of the Salish Sea was developed using FVCOM with a ≈75-100m shoreline resolution. In addition to 7 tides and 23 salinity and temperature monitoring stations, an extensive currents data set from 135 stations collected over a span of three years was used for skill assessment and validation. Explicit forward computations were then conducted to define and quantify residence and flushing times in various sub-basins of interest using (a) Lagrangian particles and (b) Numerical/virtual dye experiments. The results in most basins show expected seasonal variability with longer flushing time associated with summer lower tides and lower freshwater inflows. However, contrary to expectation, flushing time is significantly longer in wintertime in large fjord-like basins such as Hood Canal (≈138 days), likely due to increased stratification and reduced mixing. The flushing time for the Puget Sound region of the Salish Sea is ≈115 days, while Georgia Basin is 240 days when analyzed as stand-alone basins with zero background concentrations. When examined as part of the flushing of the entire Puget Sound filled with virtual dye, the compounded flushing times for embedded sub-basins can be significantly longer in order of magnitudes and largely dictated by the flushing time of Puget Sound. The computed residence and flushing time scales tabulated over 36 sub-basins provide an improved understanding of water renewal in the system, informing pollution management actions.

54 ENVIRONMENTAL SCIENCES↗

High-Level Clouds and Relation to Sea Surface Temperature as Inferred from Japan's GMS Measurements

High-level clouds have a significant impact on the radiation energy budgets and, hence, the climate of the Earth. Convective cloud systems, which are controlled by large-scale thermal and dynamical conditions, propagate rapidly within days. At this time scale, changes of sea surface temperature (SST) are small. Radiances measured by Japan's Geostationary Meteorological Satellite (GMS) are used to study the relation between high-level clouds and SST in the tropical western and central Pacific (30 S-30 N; 130 E-170 W), where the ocean is warm and deep convection is intensive. Twenty months (January 1998 - August, 1999) of GMS data are used, which cover the second half of the strong 1997-1998 El Nino. Brightness temperature at the 11-micron channel is used to identify high-level clouds. The core of convection is identified based on the difference in the brightness temperatures of the 11- and 12-micron channels. Because of the rapid movement of clouds, there is little correlation between clouds six hours apart. When most of deep convection moves to regions of high SST, the domain averaged high-level cloud amount decreases. A +2C change of SST in cloudy regions results in a relative change of -30% in high-level cloud amount. This large change in cloud amount is due to clouds moving from cool regions to warm regions but not the change in SST itself. A reduction in high-level cloud amount in the equatorial region implies an expanded dry upper troposphere in the off-equatorial region, and the greenhouse warming of high clouds and water vapor is reduced through enhanced longwave cooling to space. The results are important for understanding the physical processes relating SST, convection, and water vapor in the tropics. They are also important for validating climate simulations using global general circulation models.

Chou, Ming-Dah↗

Arsenic alters monocyte superoxide anion and nitric oxide production in environmentally exposed children

Arsenic (As) exposure has been associated with alterations in the immune system, studies in experimental models and adults have shown that these effects involve macrophage function; however, limited information is available on what type of effects could be induced in children. The aim of this study was to evaluate effects of As exposure, through the association of inorganic As (iAs) and its metabolites [monomethylated arsenic (MMA) and dimethylated arsenic (DMA)] with basal levels of nitric oxide (NO{sup {center_dot}-}) and superoxide anion (O{sub 2}{sup {center_dot}-}), in peripheral blood mononuclear cells (PBMC) and monocytes, and NO{sup {center_dot}-} and O{sub 2}{sup {center_dot}-} produced by activated monocytes. Hence, a cross-sectional study was conducted in 87 children (6-10 years old) who had been environmentally exposed to As through drinking water. Levels of urinary As species (iAs, MMA and DMA) were determined by hydride generation atomic absorption spectrometry, total As (tAs) represents the sum of iAs and its species; tAs urine levels ranged from 12.3 to 1411 {mu}g/g creatinine. Using multiple linear regression models, iAs presented a positive and statistical association with basal NO{sup {center_dot}-} in PBMC ({beta} = 0.0048, p = 0.049) and monocytes ({beta} = 0.0044, p = 0.044), while basal O{sub 2}{sup {center_dot}-} had a significant positive association with DMA ({beta} = 0.0025, p = 0.046). In activated monocytes, O{sub 2}{sup {center_dot}-} showed a statistical and positive association with iAs ({beta} = 0.0108, p = 0.023), MMA ({beta} = 0.0066, p = 0.022), DMA ({beta} = 0.0018, p = 0.015), and tAs ({beta} = 0.0013, p = 0.015). We conclude that As exposure in the studied children was positively associated with basal levels of NO{sup {center_dot}-} and O{sub 2}{sup {center_dot}-} in PBMC and monocytes, suggesting that As induces oxidative stress in circulating blood cells. Additionally, this study showed a positive association of O{sub 2}{sup {center_dot}-} production with iAs and its metabolites in stimulated monocytes, supporting previous data that suggests that these cells, and particularly the O{sub 2}{sup {center_dot}-} activation pathway, are relevant targets for As toxicity.

60 APPLIED LIFE SCIENCES↗

Super Hot EGS and the Newberry Deep Drilling Project

A productive geothermal well drilled into super-hot rock (SHR) with a temperature above 400°C will produce super-critical fluid. At a flow rate of 60 kg/s, a SHR well could produce 50 MWe compared to 5-7 MWe for the same flow at 200°C. Even though these deeper, super-hot wells will cost more, the high energy density means power produced by engineered geothermal systems (EGS) can meet the market ($46 MW-hr) by directly tapping the heat source. We propose a proof of concept where hot rock is close to the surface (~5 km), and the cost of drilling and EGS stimulation will be lowest. A suitable, ready-to-go SHR site is on Newberry Volcano, Oregon, one of the largest geothermal heat reservoirs in the USA, extensively studied for the last 40 years. Millions of dollars have already been invested in the site by private geothermal developers and the US Department of Energy (DOE), resulting in a ready-to-use facility with the necessary infrastructure, environmental permits, land commitments, and monitoring plans. The Newberry Deep Drilling Project (NDDP) will be located at an idle geothermal exploration well, NWG 46-16, drilled in 2008, 3500 m deep and 320°C at bottom, which will be deepened another 1000 to 1300 m to reach 500 °C. The original well was drilled with few lost circulation zones and the temperature profile indicates conductive heat flow. Compared to other SHR projects world-wide, this well would return more materials (cuttings, core and fluids) with more predictable drilling conditions, thus providing a suite of data near and across the brittle-ductile transition in silicarich rocks. After drilling, a hydraulic well stimulation will both change the pore pressure in fractures and cool the fracture walls resulting in permeability enhancement through both thermal fracturing, and hydro-shearing. The first step for the NDDP was an International Continental Drilling Program (ICDP) sponsored workshop held at the OSU-Cascades campus in Bend from Sept. 10-14, 2017. The workshop concluded by setting ambitious goals for NDDP: 1) test EGS above the critical point of water, 2) collect samples of rocks within the brittle-ductile transition, 3) investigate volcanic hazards, 4) study magmatic geomechanics, 5) calibrate geophysical imaging techniques, and 6) test technology for drilling, well completion, and geophysical monitoring in a very high temperature environment. The second step, completed January 15, 2018, was submitting a proposal to ICDP for 46-16 deepening. The next steps will be to continue building a team with project, technology, and investment partners to make NDDP a reality.

EGS, Geothermal, Newberry↗

In-Sodium Testing of a Prototype Thermoacoustic Power Sensor for Sodium-Cooled Fast Reactors

The ultimate goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-Cooled Fast Reactors (SFRs), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactors (LFRs), Molten Salt Reactors (MSRs), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the sensor network placed outside and/or inside of the reactor vessel. These sensors require a very small amount of power which, during loss of power events, can be provided, for example, by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. Westinghouse and the University of Pittsburgh designed and fabricated TAPS prototypes for Argonne National Laboratory (ANL) to carry out in-sodium testing to evaluate the effects of sodium on the TAPS and the performance of the TAPS technique in sodium. Argonne received a TAPS prototype from Westinghouse, and the prototype was modified such that it can be installed into a test vessel and function in sodium at elevated temperature without potentially leaking. A water mockup test apparatus was constructed to validate proper working of the prototype. An instrumentation and control (I&C) system, running on the National Instruments (NI) LabView platform, was developed to: 1) operate both the water mockup test and the in-sodium test facility; and 2) process and analyze the received acoustic signals from an array of accelerometers and the Argonne sodium-submersible high-temperature acoustic sensor. The prototype was successfully tested in a water bath at different temperatures. Water mockup tests demonstrated that the TAPS prototype is working properly and its resonance frequency changes linearly with the coolant (water) temperature. A TAPS test apparatus was constructed and integrated with the upgraded Under-Sodium Viewing (USV) sodium test facility. The integrated USV-TAPS sodium test facility has been operational. The TAPS prototype and a high-temperature sodium-submersible acoustic sensor (SSAS) developed by Argonne were both installed inside the TAPS test vessel. Being operated within argon cover gas under ambient conditions, the TAPS prototype demonstrated that it was functioning properly with a resonance frequency at 1407.2 Hz, which was successfully detected by the accelerometers mounted on the external wall of the vessel and the high-temperature SSAS installed inside the vessel. After successfully transferring sodium into the vessel, in-sodium tests of the prototype were conducted. Tests of the TAPS prototype demonstrated that the resonance frequency of the TAPS changes linearly with respect to the temperature difference between the interior of the TAPS and bulk sodium. The early tests showed that the TAPS prototype could not establish a continuous and consistent resonance in sodium. The resonance diminished before the prototype reached its operating temperature. A signal postprocessor was added to the DAQ module latterly to isolate interferences, enhance signal conditioning, improve peak detection, and generate resonance frequency versus temperature plots. After testing in molten sodium and immersion at higher temperature for several weeks, the TAPS prototype was able to establish a continuous resonance. Performance evaluation of the TAPS prototype was then conducted in sodium. The tests included the investigation of 1) the effects of the temperature difference between the TAPS and bulk sodium, 2) the effects of sodium flowrate; and 3) the performance of the different sensor-receiver systems positioned inside or outside the vessel. Results of a test demonstrated that, with limited sodium circulation, a continuous and consistent resonance of the TAPS prototype was established occasionally. The tests also demonstrated that, because of the nature of detection principles and mounting methods, the high temperature SSAS is more affected by acoustic noise, while accelerometers are more affected by vibrations, in the test environment. It is unknown why the TAPS prototype only occasionally established a continuous and consistent resonance when the TAPS temperature reached its operating temperature in molten sodium, and why it ultimately failed to resonate at all. A failure modes assessment was conducted and a few potential causes of failure were identified. Different post in-sodium tests were conducted to obtain additional information potentially relevant to the cause of the failure. Nondestructive evaluation techniques are suggested to examine the internal integrity as well as the gas mixture of the prototype. If they prove inconclusive, the prototype should be cut open to conduct a thorough inspection of its internal integrity and determine the state of the gas mixture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MELCOR Accident Progression and Source Term Demonstration Calculations for a Heat Pipe Reactor

MELCOR is an integrated thermal hydraulics, accident progression, and source term code for reactor safety analysis that has been developed at Sandia National Laboratories for the United States Nuclear Regulatory Commission (NRC) since the early 1980s. Though MELCOR originated as a light water reactor (LWR) code, development and modernization efforts have expanded its application scope to includ e non-LWR reactor concepts. Current MELCOR development efforts include providing the NRC with the analytical capabilities to support regulatory readiness for licensing non-LWR techno logies under Strategy 2 of the NRC?s near- term Implementation Action Plans. Beginning with the Next Generation Nuclear Project (NGNP), MELCOR has undergone a range of enha ncements to provide analytical capabilities for modeling the spectrum of advanced non-LWR concepts. This report describes the generic plant model developed to demonstrate MELCOR capabilities to perform heat pipe reactor (HPR) safety evaluations. The generic plant mode l is based on a publicly-available Los Alamos National Laboratory (LANL) Megapower design as modified in the Idaho National Laboratory (INL) Design A description. For plant aspects (e.g., reactor building size and leak rate) that are not described in the LANL and INL references , the analysts made assumptions needed to construct a MELCOR full-plant model. The HP R uses high assay, low-enrichment uranium (HALEU) fuel with steel cladding that uses heat pipes to transfer heat to a secondary Brayton air cycle. The core region is surrounded by a stainless-steel shroud, alumina reflector, core barrel and boron carbide neutron shield. The reactor is secured inside a below-grade cavity, with the operating floor located above the cavity. Example calculations are performed to show the plant response and MELCOR capabilities to characterize a range of accident conditions. The accidents selected for evaluation consider a range of degraded and failed modes of operation for key safety functions providing re activity control, the primary and secondary system heat removal, and the effectiveness of th e confinement natural circulation flow into the reactor cavity (i.e., a flow blockage).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Spatial and temporal variability of tritium in precipitation within South Africa and it's bearing on hydrological studies

Tritium, the radioactive isotope of hydrogen, has been used to understand groundwater recharge processes for decades. The current variation of tritium in the atmosphere is largely attributed to stratospheric production and fall out rates as well as global circulation phenomena controlling the hydrological cycle. Global controls on the variability in atmospheric tritium activity are poorly suited to explain local variation and tritium activities in precipitation are often assumed to be uniform over both local and regional catchments and watersheds. This assumption can result in both over and under estimation of modern recharge within an aquifer when using tritium as the recharge proxy. In order to minimize the inherent prediction residuals associated with tritium based recharge investigations, the variability of tritium in precipitation was modelled from 127 spatial precipitation samples taken over a two year period, combined with a 76 precipitation sample group-set taken over a one year period in a single location. Precipitation events were traced backward in time, from the point of collection, using HYSPLIT modelling to ascertain the origins of moisture content as well as the altitudes of moisture origin reached along the particle track. Tritium activities, collected over a one year period in Paarl, range from 0.45 to 4.16 TU and have a mean of 1.59 TU. Spatial storm events in the Western Cape in 2017 and 2018 had a range from 0 to 2.2 and 0.37 to 3.27 TU, respectively, with mean activities of 1.18 (n = 34) and 1.25 TU (n = 32). Both storm events had similar tritium variability (σ = 0.5 n = 35 and 0.48 n = 32). Regional precipitation events had the largest range of tritium activities (0.55–12.2 TU). Although not all tritium activities can be explained by interrogating the water mass origin, this study suggests that approximately 90% of events can be completely or partially attributed to the origin of the water mass. The variability of tritium, both spatially and temporally, was higher than expected, confirming that when uniform tritium inputs are used, the groundwater system would provide inaccurate modern recharge estimates. Higher spatial resolution of tritium variation in precipitation for a particular region will improve our ability to relate tritium activities in groundwater to local precipitation.

54 ENVIRONMENTAL SCIENCES↗

Biogeophysical Effects of Land-Use and Land-Cover Change Not Detectable in Warmest Month

Land-use and land-cover changes (hereafter simply “land use”) alter climates biogeophysically by affecting surface fluxes of energy and water. Yet, near-surface temperature responses to land use across observational versus model-based studies and spatial-temporal scales can be inconsistent. Here we assess the prevalence of the historical land use signal of daily maximum temperatures averaged over the warmest month of the year (t LU ) using regularized optimal fingerprinting for detection and attribution. We use observations from the Climatic Research Unit and Berkeley Earth alongside historical simulations with and without land use from phase 6 of the Coupled Model Intercomparison Project to reconstruct an experiment representing the effects of land use on climate. To assess the signal of land use at spatially resolved continental and global scales, we aggregate all input data across reference regions and continents, respectively. At both scales, land use does not comprise a significantly detectable set of forcings for two of four Earth system models and their multimodel mean. Furthermore, using a principal component analysis, we find that t LU is mostly composed of the nonlocal effects of land use rather than its local effects. These findings show that, at scales relevant for climate attribution, uncertainties in Earth system model representations of land use are too high relative to the effects of internal variability to confidently assess land use.

54 ENVIRONMENTAL SCIENCES↗