Search NASA⌕ Search

SEARCH · Search NASA

Results for “Clocks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Characterization of frequency standard instability by estimation of their covariance matrix

The popular 3-cornered hat method used for evaluating the noise contributions of individual frequency standards is revisited. This method is used in several cases, but sometimes the results are not consistent because one or more estimated clock variances turn out to be negative. Different causes of this unacceptable result have been conjectured: among them one regards the hypothesis of uncorrelated clocks, essential in this method. Since recently realistic cases of correlation between clocks, mainly due to the environmental conditions, have been observed, this paper proposes an entirely revisited version of the 3-cornered hat method which permits to evaluate the individual variances and also the possible covariances between clocks, by relaxing the hypothesis of uncorrelation. The uncertainty and the lack of contemporaneity of the measurement series are assumed to be negligible. The lack of the uncorrelation hypothesis calls for a more general mathematical model leading to an underdetermined linear system. The estimates of the (co)variances of the measurement series us well us those of the individual clocks are introduced by means of the scalar product of the related time series and arranged in the respective covariance matrices S and R. Since covariance matrix is positive definite by definition, the problem consists in estimating the unknown R, subject to the constraint of positive definiteness, from the known S. Unfortunately, this constraint is not sufficient to estimate R. Therefore a suitable optimization criterion is proposed, which assures the positive definiteness of R and, at the same time, minimizes the global correlation among clocks. Examples of frequency instability measurements processed by the "classical" 3-cornered hat method and the here-revisited method are presented showing that the solutions are identical only when the uncorrelation hypothesis doesn't violate the positive definiteness of R.

PatriziaTravella↗

TimeSet: A computer program that accesses five atomic time services on two continents

TimeSet is a shareware program for accessing digital time services by telephone. At its initial release, it was capable of capturing time signals only from the U.S. Naval Observatory to set a computer's clock. Later the ability to synchronize with the National Institute of Standards and Technology was added. Now, in Version 7.10, TimeSet is able to access three additional telephone time services in Europe - in Sweden, Austria, and Italy - making a total of five official services addressable by the program. A companion program, TimeGen, allows yet another source of telephone time data strings for callers equipped with TimeSet version 7.10. TimeGen synthesizes UTC time data strings in the Naval Observatory's format from an accurately set and maintained DOS computer clock, and transmits them to callers. This allows an unlimited number of 'freelance' time generating stations to be created. Timesetting from TimeGen is made feasible by the advent of Becker's RighTime, a shareware program that learns the drift characteristics of a computer's clock and continuously applies a correction to keep it accurate, and also brings .01 second resolution to the DOS clock. With clock regulation by RighTime and periodic update calls by the TimeGen station to an official time source via TimeSet, TimeGen offers the same degree of accuracy within the resolution of the computer clock as any official atomic time source.

Petrakis, P. L.↗

(T2L2) Time Transfer by Laser Link

T2L2 (Time Transfer by Laser Link) is a new generation time transfer experiment based on the principles of LASSO (Laser Synchronization from Synchronous Orbit) and used with an operational procedure developed at OCA (Observatoire de la Cote d'Azur) during the active intercontinental phase of LASSO. The hardware improvements could lead to a precision better than 10 ps for time transfer (flying clock monitoring or ground based clock comparison). Such a package could fly on any spacecraft with a stable clock. It has been developed in France in the frame of the PHARAO project (cooled atom clock in orbit) involving CNES and different laboratories. But T2L2 could fly on any spacecraft carrying a stable oscillator. A GPS satellite would be a good candidate, as T2L2 could allow to link the flying clock directly to ground clocks using light, aiming to important accuracy checks, both for time and for geodesy. Radioastron (a flying VLBI antenna with a H-maser) is also envisioned, waiting for a PHARAO flight. The ultimate goal of T2L2 is to be part of more ambitious missions, as SORT (Solar Orbit Relativity Test), aiming to examine aspects of the gravitation in the vicinity of the Sun.

Veillet, Christian↗

Appendix A: The Impact of the HP 5071A on International Atomic Time

The international clock ensemble, which contributes to the generation of International Atomic Time (TAI and UTC) has improved dramatically over the last few years. The main change has been the introduction of a significant number of HP 5071A clocks. Of the 313 clocks contributing to TAI/UTC during 1994, 94 of these were HP 5071As. The environmental insensitivity of the HP 5071A clocks is more than an order of magnitude better than that of previously contributing clocks. This environmental insensitivity translates to outstanding long-term stability - with a typical flicker floor of a few x10(sup -15). in addition, there are now several hydrogen masers with cavity tuning contributing to TAI/UTC. These not only have outstanding short-term stability, but comparatively low frequency drifts and excellent intermediate-type frequency stability. By analyzing data available from the international ensemble, we have obtained two important results. First the frequency stability obtainable with an optimum algorithm is about 10(sup -15) for both the intermediate and long-term regions. It could be as good in the short-term (if time transfer measurement instabilities were reduced sufficiently. Second, with cooperation, this performance can be made available on an international basis in near real time. The recent enhancements in the contributing clocks are already providing a significant improvement in the accuracy with which UTC is made available to the world from several of the national timing centers, such as the National Institute for Standards and Technology (NIST) and the US Naval Observatory (USNO).

Allan, David W.↗

Ultralow-Power Digital Correlator for Microwave Polarimetry

A recently developed high-speed digital correlator is especially well suited for processing readings of a passive microwave polarimeter. This circuit computes the autocorrelations of, and the cross-correlations among, data in four digital input streams representing samples of in-phase (I) and quadrature (Q) components of two intermediate-frequency (IF) signals, denoted A and B, that are generated in heterodyne reception of two microwave signals. The IF signals arriving at the correlator input terminals have been digitized to three levels (-1,0,1) at a sampling rate up to 500 MHz. Two bits (representing sign and magnitude) are needed to represent the instantaneous datum in each input channel; hence, eight bits are needed to represent the four input signals during any given cycle of the sampling clock. The accumulation (integration) time for the correlation is programmable in increments of 2(exp 8) cycles of the sampling clock, up to a maximum of 2(exp 24) cycles. The basic functionality of the correlator is embodied in 16 correlation slices, each of which contains identical logic circuits and counters (see figure). The first stage of each correlation slice is a logic gate that computes one of the desired correlations (for example, the autocorrelation of the I component of A or the negative of the cross-correlation of the I component of A and the Q component of B). The sampling of the output of the logic gate output is controlled by the sampling-clock signal, and an 8-bit counter increments in every clock cycle when the logic gate generates output. The most significant bit of the 8-bit counter is sampled by a 16-bit counter with a clock signal at 2(exp 8) the frequency of the sampling clock. The 16-bit counter is incremented every time the 8-bit counter rolls over.

Piepmeier, Jeffrey R.↗

Laser Communications Relay Demonstration Optimetrics Experiment

Within this paper, we report on an Optimetrics experiment conducted on the National Aeronautics and Space Administration (NASA) Laser Communication Relay Demonstration (LCRD). The high precision two-way ranging is conducted on the optical communications link between the LCRD space terminal in a geosynchronous orbit and the Optical Ground Station 1 (OGS1) at Table Mountain, California, and is referred to as optimetrics ranging. The receiver to transmitter clock loopback is implemented in the LCRD space modem. A digital dual mixer time difference phase meter (DDMTD) is implemented in the OGS1 ground modem. The round-trip time is measured with the DDMTD by counting the frame and data clock ticks between transmitter and receiver frame synchronization markers for coarse range, and the relative phase of the transmit and receive clock for high precision range. This approach provides coverage for all potential ranges with no ranging ambiguity. The flight modem FPGA code was modified for frame and data clock loopback and the OGS1 FPGA code was modified for the DDMTD phase meter implementation. The experiment team conducted a 36-hour continuous ranging measurement. Preliminary two-way optimetrics ranging data show a noise floor of 3cm (rms). Based on our theoretical noise analysis and ground tests with spare flight modems, we expected one order of magnitude improvement on ranging precision. We are conducting detailed post data processing to identify the differences to further reduce the noise level and formulating an improved implementation approach for future missions. For reference and comparison, traditional Radio Frequency (RF) ranging between LCRD and OGS1 was conducted at the same time and indicates a ranging noise floor of 30cm(rms). Other telemetry and relevant environmental parameters such as weather and atmosphere temperature were also collected for offline data processing. The high precision ranging and range rate measurements from the laser communications data link clock and clock phase are performed simultaneously with continuous optical communication. No extra hardware added to existing system. This high precision optimetrics measurement implementation provides alternative ranging and range rate measurements for orbit determination (OD) and flight dynamics calculations with higher precision. We see significant improvement on OD for navigation upon implementation in future optical communication systems.

Rafael Garcia↗

Synchronization system and method for wireless communicating nodes

A system includes first and second wireless nodes having a clock with plural times, a wireless transceiver, and a processor cooperating with the transceiver to transmit and receive packets. The second node transceivers wirelessly communicate with the first or other second node transceivers. The second nodes include a Kalman filter with an output, plural filter gains, and an input representing the difference between: about the time of the clock when a received packet should have ideally been received, and a time when the received packet was actually received as measured by the clock. A circuit provides dynamic adjustment of the filter gains. The Kalman filter output estimates the difference between the time of the receiving node clock and a corresponding one of the times of the transmitting node clock. The second processor cooperates with the Kalman filter output to adjust the times of the receiving node clock.

Armstrong, Brian S. R.↗

Dynamic voltage frequency scaling based on active memory barriers

A processing unit includes compute units partitioned into one or islands that are provided with operating voltages and clock signals having clock frequencies independent of providing operating voltages or clock signals to other islands of compute units. The processing unit also includes dynamic voltage and frequency scaling (DVFS) hardware configured to compute one or more numbers of active memory barriers in the one or more islands. The DVFS hardware is also configured to modify the operating voltages or clock frequencies provided to the one or more islands in response to a change in numbers of active memory barriers in the one or more islands. In some cases, the operating voltage or clock frequency provided to an island is increased in response to the number of active memory barriers in the island decreasing. The operating voltage or clock frequency provided to the island is decreased in response to the number of active memory barriers in the island increasing.

Bharadwaj, Vedula Venkata Srikant↗

Performance of 3 cm 3 ion trap vacuum package sealed for 10 years

Miniature atomic clocks based on the interrogation of the ground state hyperfine splitting of buffer gas cooled ions confined in radio frequency Paul traps have shown great promise as high precision prototype clocks. We report on the performance of two miniature ion trap vacuum packages after being sealed for as much as 10 years. We find the lifetime of the ions within the trap has increased over time for both traps and can be as long as 50 days. We form two clocks using the two traps and compare their relative frequency instability one with another to demonstrate a short-term instability of 5×10 -13 $τ$ -1/2 integrating down to 1×10 -14 after 2 ks of integration. The trapped ion lifetime and clock instability demonstrated by these miniature devices despite only being passively pumped for many years represents a critical advance toward their proliferation in the clock community.

74 ATOMIC AND MOLECULAR PHYSICS↗

The anatomy of the renal pyelocaliceal system studied by CTU

Introduction and objectives: Knowledge of the pyelocaliceal system anatomy is essential for the safe and successful performance of endourologic procedures. The purpose of this study was to provide a better understanding of the full three-dimensional pyelocaliceal system anatomy. Methods: Morphometric parameters of the three-dimensional reconstructions of computed tomography intravenous urography scans (n = 25 scans) were analyzed. Both kidneys were divided into three equal-sized segments (US: upper segment, MS: mid segment, LS: lower segment). Infundibular length (IL), infundibular width (IW), the number of calyces, and the transverse orientation in hours of a clock of each calyx as well as the dimension of the pyelum were determined. Results: The mean upper IL (n = 92) was longer than the middle (n = 154) and lower IL (n = 112) (30.6 ± 7.9 mm vs. 16.4 ± 7.7 mm vs. 16.0 ± 6.0 mm, respectively; P = < 0.0001). IW was significantly smaller in the MS [3.7 ± 1.9 mm], followed by the US [4.6 ± 1.9 mm], and the LS [4.9 ± 2.2] in the increasing order. No correlation was found between IL and IW (Pearson correlation coefficient = 0.1). The US calyces were predominantly orientated lateral (8-10 o’clock: 44.5%) and medial (2–4 o’clock: 30.5%), in the MS lateral (8–10 o’clock: 87.6%) and anterolateral in the LS (9–12 o’clock: 67.9%). 74% of the kidneys consisted of 6–8 calyces (mean 7.2 ± 1.4, range 4–10), with the majority of the calyces in the MS (3.1 ± 0.8) followed by the LS (2.24 ± 0.8), and US (1.8 ± 0.7). There were no statistical differences between the right and left kidneys in terms of IL (P = 0.112) and number of calyces (P = 0.685). Conclusion: Anatomic differences between the three segments of the pyelocaliceal system in terms of IL, IW, calyces number, and orientation are seen and should be considered when performing an endourologic procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Altered Stra13 and Dec2 circadian gene expression in hypoxic cells

The circadian system regulates rhythmically most of the mammalian physiology in synchrony with the environmental light/dark cycle. Alteration of circadian clock gene expression has been associated with tumour progression but the molecular links between the two mechanisms remain poorly defined. Here we show that Stra13 and Dec2, two circadian transcriptional regulators which play a crucial role in cell proliferation and apoptosis are overexpressed and no longer rhythmic in serum shocked fibroblasts treated with CoCl{sub 2,} a substitute of hypoxia. This effect is associated with a loss of circadian expression of the clock genes Rev-erb{alpha} and Bmal1, and the clock-controlled gene Dbp. Consistently, cotransfection assays demonstrate that STRA13 and DEC2 both antagonize CLOCK:BMAL1 dependent transactivation of the Rev-erb{alpha} and Dbp promoters. Using a transplantable osteosarcoma tumour model, we show that hypoxia is associated with altered circadian expression of Stra13, Dec2, Rev-erb{alpha}, Bmal1 and Dbp in vivo. These observations collectively support the notion that overexpression of Stra13 and Dec2 links hypoxia signalling to altered circadian clock gene expression.

60 APPLIED LIFE SCIENCES↗

An experiment to verify that the weak interactions satisfy the strong equivalence principle

The construction of a clock based on the beta decay process is proposed to test for any violations by the weak interaction of the strong equivalence principle bu determining whether the weak interaction coupling constant beta is spatially constant or whether it is a function of gravitational potential (U). The clock can be constructed by simply counting the beta disintegrations of some suitable source. The total number of counts are to be taken a measure of elapsed time. The accuracy of the clock is limited by the statistical fluctuations in the number of counts, N, which is equal to the square root of N. Increasing N gives a corresponding increase in accuracy. A source based on the electron capture process can be used so as to avoid low energy electron discrimination problems. Solid state and gaseous detectors are being considered. While the accuracy of this type of beta decay clock is much less than clocks based on the electromagnetic interaction, there is a corresponding lack of knowledge of the behavior of beta as a function of gravitational potential. No predictions from nonmetric theories as to variations in beta are available as yet, but they may occur at the U/sg C level.

Eby, P. B.↗

Time determination for spacecraft users of the Navstar Global Positioning System /GPS/

Global Positioning System (GPS) navigation is performed by time measurements. A description is presented of a two body model of spacecraft motion. Orbit determination is the process of inferring the position, velocity, and clock offset of the user from measurements made of the user motion in the Newtonian coordinate system. To illustrate the effect of clock errors and the accuracy with which the user spacecraft time and orbit may be determined, a low-earth-orbit spacecraft (Seasat) as tracked by six Phase I GPS space vehicles is considered. The obtained results indicate that in the absence of unmodeled dynamic parameter errors clock biases may be determined to the nanosecond level. There is, however, a high correlation between the clock bias and the uncertainty in the gravitational parameter GM, i.e., the product of the universal gravitational constant and the total mass of the earth. It is, therefore, not possible to determine clock bias to better than 25 nanosecond accuracy in the presence of a gravitational error of one part per million.

Grenchik, T. J.↗

Precise time transfer using MKIII VLBI technology

It is well known that Very Long Baseline Interferometry (VLBI) is capable of precise time synchronization at subnanosecond levels. This paper deals with a demonstration of clock synchronization using the MKIII VBLI system. The results are compared with clock synchronization by traveling cesium clocks and GPS. The comparison agrees within the errors of the portable clocks (+ 5 ns) and GPS(+ or - 30 ns) systems. The MKIII technology appears to be capable of clock synchronization at subnanosecond levels and appears to be very good benchmark system against which future time synchronization systems can be evaluated.

Johnston, K. J.↗

The time and frequency comparisons via Loran-C and National TV Network in Yugoslavia

Time comparisons were made between cesium clocks in Yugoslavia and other cesium clocks in the country by the Laboratory of Federal Bureau of Measures and Precious Metals. Regional standard frequency and time signals dissemination is over National TV network by so called active TV system. International comparisons are performed via Loran-C system and by clock transportation. The method of calculation and approximation of the time signal propagation delays is given. Settled comparison results of the cesium clocks via TV network, Loran-C, and by clock transportation are also discussed in this paper.

Markovic, Z. M.↗

Synchronization tracking in pulse position modulation receiver

A clock pulse generator for decoding pulse position modulation in an optical communication receiver is synchronized by a delay tracking loop which multiplies impulses of a data pulse by the square wave clock pulses from the generator to produce positive impulses when the clock pulse is of one level, and negative impulses when the clock pulse is of another level. A delay tracking loop integrates the impulses and produces an error signal that adjusts the delay so the clock pulses will be synchronized with data pulses. A dead-time tau sub d is provided between data pulses of an interval tau sub p in the data pulse period tau. When synchronized, the average number of positive impulses integrated will equal the average number of negative impulses over the continuous stream of data pulses.

Vilnrotter, Victor A.↗

Results of using the global positioning system to maintain the time and frequency synchronization in the Deep Space Network

There are two hydrogen maser clocks located at each signal processing center (SPC) in the DSN. Close coordination of the time and frequency of the SPC clocks is needed to navigate spacecraft to the outer planets. A recent example was the Voyager spacecraft's encounter with Uranus in January 1986. The clocks were adjusted with the goal of minimizing time and frequency offsets between the SPCs at encounter. How time and frequency at each SPC is estimated using data acquired from the Global Positioning System Timing Receivers operating on the NBS-BIH (National Bureau of Standards-Bureau International de l'Heure) tracking schedule is described. These data are combined with other available timing receiver data to calculate the time offset estimates. The adjustment of the clocks is described. It was determined that long range hydrogen maser drift is quite predictable and adjustable within limits. This enables one to minimize time and frequency differences between the three SPCs for many months by matching the drift rates of the three standards. Data acquisition and processing techniques using a Kalman filter to make estimates of time and frequency offsets between the clocks at the SPCs and UTC(NBS) (Coordinated Universal Time realized at NBS) are described.

Clements, P. A.↗

The Navstar GPS master control station's Kalman filter experience

The Navstar Global Positioning System (GPS) is a highly accurate space based navigation system providing all weather, 24 hour a day service to both military and civilian users. The system provides a Gaussian position solution with four satellites, each providing its ephemeris and clock offset with respect to GPS time. The GPS Master Clock Station (MCS) is charged with tracking each Navstar spacecraft and precisely defining the ephemeris and clock parameters for upload into the vehicle's navigation message. Briefly described here are the Navstar system and the Kalman filter estimation process used by MCS to determine, predict, and ensure quality control for each of the satellite's ephemeris and clock states. Routine performance is shown. Kalman filter reaction and response is discussed for anomalous clock behavior and trajectory perturbations. Particular attention is given to MCS efforts to improve orbital adjust modeling. The satellite out of service time due to orbital maneuvering has been reduced in the past year from four days to under twelve hours. The planning, reference trajectory model, and Kalman filter management improvements are explained.

Scardera, Michael P.↗