Search NASA⌕ Search

SEARCH · Search NASA

Results for “Configuration Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Load Mitigation on Floating Offshore Wind Turbines with Advanced Controls and Tuned Mass Dampers

General Electric, the National Renewable Energy Laboratory (NREL), the University of Massachusetts Amherst (UMass), and Glosten have recently completed a US Department of Energy (DOE)-funded research program to study technologies for mitigating loads on floating offshore wind turbines through the use of advanced turbine controls and tuned mass dampers (TMDs). The analysis was based upon the Glosten PelaStar tension leg platform (TLP) with GE Haliade 150 turbine, a system developed in a previous front end engineering design (FEED) study funded by the Energy Technology Institute (ETI) in the UK. The platform was designed for the WaveHub wave energy research site, with a mean water depth of 59-m. Loads were analyzed by running time-domain simulations in four 50-year return period (50-YRP) ultimate load state (ULS) conditions and 77 fatigue load state (FLS) environmental conditions. In 50-YRP conditions advanced controls are not active. The influence of TMDs on ULS loads have been reported previously (Park et al. [2]). In FLS conditions advanced controls and TMDs afford dramatic reductions in fatigue damage, offering the potential of significant savings in tower structural requirements. Simulations in turbine idling conditions were run in OrcaFlex, and simulations in operating conditions were run in FAST. Simulations were run with a baseline turbine controller, representative of the current state of the art, and an advanced controller developed by NREL to use collective and individual blade pitch control to maintain rotor speed and reduce tower loads. UMass developed a number of TMD types, with varying system configurations, including passive nonlinear dampers and semi-actively controlled dampers with an inverse velocity groundhook control algorithm. Loads and accelerations in FLS conditions were evaluated on the basis of damage equivalent loads (DELs), and fatigue damage was computed by Miner's summations of stress cycles at the tower base. To study sensitivity to water depth, loads were analyzed at both the 59-m WaveHub depth and a more commercially realistic depth of 100 m. TMDs reduce fatigue damage at the tower-column interface flange by up to 52% in 59-m water depth and up to 28% in 100 m water depth. Advanced controls reduce fatigue damage at the tower-column flange by up to 22% in 59-m water depth and up to 40% in 100 m water depth. The most effective load-mitigation strategy is combining advanced controls with TMDs. This strategy affords a 71% reduction in fatigue damage in both 59-m and 100-m water depths.

17 WIND ENERGY↗

Mercury control in 2009

Although activated carbon injection (ACI) has been proven to be effective for many configurations and is a preferred option at many plants sufficient quantities of powdered activated coking (PAC) must be available to meet future needs. The authors estimate that upcoming federal and state regulations will result in tripling the annual US demand for activated carbon to nearly 1.5 billion lb from approximately 450 million lb. Rapid expansion of US production capacity is required. Many PAC manufacturers are discussing expansion of their existing production capabilities. One company, ADA Carbon Solutions, is in the process of constructing the largest activated carbon facility in North America to meet the future demand for PAC as a sorbent for mercury control. Emission control technology development and commercialization is driven by regulation and legislation. Although ACI will not achieve > 90% mercury control at every plant, the expected required MACT legislation level, it offers promise as a low-cost primary mercury control technology option for many configurations and an important trim technology for others. ACI has emerged as the clear mercury-specific control option of choice, representing over 98% of the commercial mercury control system orders to date. As state regulations are implemented and the potential for a federal rule becomes more imminent, suppliers are continuing to develop technologies to improve the cost effectiveness and limit the balance of plant impacts associated with ACI and are developing additional PAC production capabilities to ensure that the industry's needs are met. The commercialisation of ACI is a clear example of industry, through the dedication of many individuals and companies with support from the DOE and EPRI, meeting the challenge of developing cost-effectively reducing emissions from coal-fired power plants. 7 refs., 1 fig.

01 COAL, LIGNITE, AND PEAT↗

Maximum-impact Adversary Design for Network-based Control System: A Case Study on Grid-interactive Efficient Buildings

The Internet of Things (IoT) technology has dramatically improved the efficiency of today's building operation and management. By connecting controllable devices into a communication network, control signals can be easily passed to the devices, and operating status can be acquired from measurable ends with minimal effort. However, this all-connected configuration could also expose the network-based control system (NBCS) to malicious actions, such as cyberattacks. One of the common NBCSs is the building automation system. With the promotion of grid-interactive efficient buildings (GEBs), there has been increasing attention on securing the buildings from the network perspective. This research proposes a maximum-impact adversary design framework so that the adversary can provide the most adversarial impact on the controlled system while remaining stealthy. The proposed framework is numerically demonstrated on a network-based building energy and control system. The building energy system is built in a Modelica-based simulation environment and controlled by the state-of-the-art ASHRAE Guideline 36 control sequences. The control commands at the supervisory level, generated from the Guideline 36 controller, are assumed to be sent to local devices through communication networks using the BACnet protocol. Simulation results show that the proposed maximum-impact adversary on such a system can stealthily affect the building system's performance to its maximum extent. It is anticipated that results can be used by researchers and practitioners in the building automation industry to design efficient and robust cyber-attack detection algorithms, especially for stealthy attacks.

Chu, Mengyuan↗

Modeling Assessment of Residential Air-to-Water Heat Pumps Coupled with Cooling Thermal Storage

This study explored the performance and operating cost viability of air-to-water heat pumps (AWHPs) coupled with thermal energy storage (TES) in efficient new residential construction. AWHPs are an emerging technology in this country, but offer promise in terms of high efficiency, fully contained and factory charged outdoor refrigeration system, and hydronic delivery capabilities, which facilitates zoning, ducts in conditioned space, and TES integration for summer load-shifting. Although this AWHP+TES strategy is not yet mainstream, the authors feel that in ten years as decarbonization efforts proceed and TOU rates become more common, strategies such as this will be more accessible. Validated EnergyPlus simulation models were developed based on detailed monitoring data collected over several years at Pacific Gas and Electric's CVRH laboratory test homes located in Stockton, California. One of the CVRH test homes (1,962 ft 2 two-story) had been testing various AWHP systems and configurations over the past six years. The validated model was then updated with high efficiency IECC ZERH envelope and component requirements for climate zones 1-5, including ducts in conditioned space thermal distribution. Simulations were completed for the 1,962 ft 2 home in each climate zone for a minimum efficiency ASHP, an AWHP coupled with a fan coil, and an AWHP coupled with TES sized to eliminate summer on-peak compressor operation. To maintain consistency in reporting energy use estimates, all cases were run with a similar indoor thermostat control strategy to pre-cool the house below the nominal 76 degrees Fahrenheit set point prior to the on-peak period and float slightly above the set point during the peak period. The AWHP+TES configuration was controlled to alternately condition the indoor space or to charge the TES tanks prior to the beginning of the on-peak. Three composite TOU rates were developed based on existing TOU rates across the U.S. to provide differing economic scenarios to evaluate customer bill impacts throughout the summer. Two of the TOU rates had short three-hour peak periods, while the third rate had a longer seven-hour duration peak period. AWHP modeling projections were based on the observed field performance of the Chiltrix CX34 variable speed unit. Other products on the market or entering the market in the near term would likely perform differently.

25 ENERGY STORAGE↗

Tuning of Nacelle Feedback Gains for Floating Wind Turbine Controllers Using a Two-DOF Model

Designing a collective blade pitch controller for floating offshore wind turbines (FOWTs) poses unique challenges due to the interaction of the controller with the dynamics of the platform. The controller must also handle the competing objectives of power production performance and fatigue load management. Existing solutions either detune the controller with the result of slowed response, make use of complicated tuning methods, or incorporate a nacelle velocity feedback gain. With the goal of developing a simple control tuning method for the general FOWT researcher that is easily extensible to a wide array of turbine and hull configurations, this last idea is built upon by proposing a simple tuning strategy for the feedback gain. This strategy uses a two degree-of-freedom (DoF) turbine model that considers tower-top fore-aft and rotor angular displacements. For evaluation, the nacelle velocity term is added to an existing gain scheduled proportional-integral controller as a proportional gain. The modified controller is then compared to baseline land-based and detuned controllers on an example system for several load cases. First-pass results are favorable, demonstrating how researchers can use the proposed tuning method to efficiently schedule gains for adequate controller performance as they investigate new FOWT configurations.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

Genesis of a novel high-rate composite manufacturing process using large-scale additive manufacturing – compression molding (AM-CM) system: Possibilities and limitations

Oak Ridge National Laboratory (ORNL) has developed a highly automated manufacturing process for thermoplastic composites that combines the benefits of Additive Manufacturing and Compression Molding (AM-CM) to produce high-performance functional composite structures at automotive production rates. Here, the AM-CM process creates highly precise preforms by additively placing extruded fiber-filled polymers (with controlled fiber orientations and multi-material configurations) in the desired mold location before undergoing a secondary compression molding process immediately before the preform cools down. Preforms can be in the form of short, long-chopped, or continuous fiber-filled thermoplastic polymers (e.g., CF/GF-filled ABS, PC, LM-PAEK, etc.). The AM-CM process combines the benefits of controlled fiber alignment, that is only achievable in AM-printed parts with the classical CM process, which eliminates porosity and good surface finish. A preform created using AM-CM can integrate various materials to enable additional architectural functionalities, including over-molding, selective stiffening, and the incorporation of electrically or thermally conductive channels. All these advantages come with a fast part production cycle time. The AM-CM process can manufacture multi-material, multi-functional parts in under 3 min, starting from raw material (pellets) to the final product. The novel AM-CM process offers superior microstructural control and enhanced multi-functionality previously unattainable with any other traditional high-rate thermoplastic composite manufacturing method. This work covers the manufacturing concept, system development, materials and applications of AM-CM process in detail.

Kumar, Vipin [Oak Ridge National Laboratory (ORNL)↗

An Exhaust Catalyst Simulator (ExhCatSim): Reducing Catalyst Development Costs and Improving the Performance of Exhaust Aftertreatment Systems

The proposed ExhCatSim software tool can be used to account for CO/HC/NOx/PM emissions controls required by EPA regulation standards via the integration of variable catalysts listed in the tool, e.g. exploring various aftertreatment configurations and technologies (like DOC/DPF/SCR/ASC) for extra low emissions control. Moreover, the software tool can be used to investigate the tradeoff between cost and catalytic performance.

Gao, Zhiming↗

A reference open-source controller for fixed and floating offshore wind turbines

Abstract. This paper describes the development of a new reference controller framework for fixed and floating offshore wind turbines that greatly facilitates controller tuning and represents standard industry practices. The reference wind turbine controllers that are most commonly cited in the literature have been developed to work with specific reference wind turbines. Although these controllers have provided standard control functionalities, they are often not easy to modify for use on other turbines, so it has been challenging for researchers to run representative, fully dynamic simulations of other wind turbine designs. The Reference Open-Source Controller (ROSCO) has been developed to provide a modular reference wind turbine controller that represents industry standards and performs comparably to or better than existing reference controllers. The formulation of the ROSCO controller logic and tuning processes is presented in this paper. Control capabilities such as tip speed ratio tracking generator torque control, minimum pitch saturation, wind speed estimation, and a smoothing algorithm at near-rated operation are included to provide modern controller features. A floating offshore wind turbine feedback module is also included to facilitate growing research in the floating offshore arena. All of the standard controller implementations and control modules are automatically tuned such that a non-controls engineer or automated optimization routine can easily improve the controller performance. This article provides the framework and theoretical basis for the ROSCO controller modules and generic tuning processes. Simulations of the National Renewable Energy Laboratory (NREL) 5 MW reference wind turbine and International Energy Agency 15 MW reference turbine on the University of Maine semisubmersible platform are analyzed to demonstrate the controller's performance in both fixed and floating configurations, respectively. The simulation results demonstrate ROSCO's peak shaving routine to reduce maximum rotor thrusts by over 10 % compared to the NREL 5 MW reference wind turbine controller on the land-based turbine and to reduce maximum platform pitch angles by nearly 30 % when using the platform feedback routine instead of a more traditional low-bandwidth controller.

17 WIND ENERGY↗

Design and Performance Evaluation of a Resistive Control Using a Hydraulic PTO System for the TALOS Wave Energy Converter

This study is focused on developing a numerical model to evaluate the performance of a hydraulic PTO system for the TALOS Wave Energy Converter. The WEC device is described and the architecture of the hydraulic PTO system is presented with detail. The WEC is modeled using WEC-Sim, and the PTO is modeled using the Simscape Fluids library from Simulink. The hydraulic PTO is based on a constant pressure configuration that is suitable for WEC passive control. The hydraulic system is composed by a set of rectifying valves and two hydraulic accumulators that reduce the stiffness of the system and also serve as energy storage devices. One of the advantages of this hydraulic PTO architecture is the possibility of controlling the electric generator to operate around the optimal efficiency operating point. The main components of the hydraulic PTO are off-the-shelf devices that are commercially available, which will facility a future deployment of the designed system. The design variables used for this study are the accumulator size, the maximum pressure in the accumulators, the hydraulic motor maximum displacement, and the shaft speed in the electric generator. The performance of the system is evaluated individually, using sinusoidal inputs that replicates regular wave conditions. In addition to this, the numerical model of the PTO is coupled to a WEC-Sim simulation of the TALOS Wave Energy Converter with six PTOs to generate a wave-to-wire model. The main objective of this work is to present a comprehensive design methodology that could serve as a guideline for future research efforts focused on implementing control algorithms on multi degree of freedom WECs.

hydraulic systems↗

MPC solution for optimal load shifting for buildings with ON/OFF staged packaged units: Experimental demonstration, and lessons learned

Small and medium-sized commercial buildings (SMCB) are significant demand response resources, and it is important to develop grid-responsive control algorithms that exploit those resources and create financial benefits for building owners and HVAC service providers. Furthermore, unlike large-sized commercial buildings, there is an opportunity to have universally applicable control solutions for many SMCBs since those buildings have a consistent HVAC system configuration: SMCBs are commonly served by multiple-staged air conditioning units controlled by their own thermostats. Despite the demand response potential and scalability, however, very few control solutions are available for SMCBs. Typical model predictive control (MPC) and heuristic control approaches for cooling load shifting that lower thermostat setpoints before an electric price jump are suitable mainly for large-sized commercial buildings where a continuous capacity modulation is possible, e.g., via dampers in variable air volume terminal units. However, those approaches can cause undesired, high peaks for SMCBs due to the nature of ON/OFF unit staging and narrow thermostat deadbands. This could discourage the use of advanced grid-responsive controls for SMCBs due to the concern of high demand charges, and has to be resolved. This paper presents a MPC solution that overcomes this challenge. It has a hierarchical MPC structure where an upper level MPC is responsible for electrical load shifting in response to an electric price signal while a lower level MPC is responsible for coordinating compressor stages to eliminate unnecessary peaks and follows the setpoints determined by the upper level MPC. In this work, two one-month, comprehensive laboratory tests have been carried out to demonstrate load shifting and cost savings for the algorithm. Interesting trade-offs between energy efficiency and load flexibility were observed and are discussed, and lessons learned for applying MPCs for SMCBs are also presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Practical factors of envelope model setup and their effects on the performance of model predictive control for building heating, ventilating, and air conditioning systems

Model predictive control (MPC) for buildings is attracting significant attention in research and industry due to its potential to address a number of challenges facing the building industry, including energy cost reduction, grid integration, and occupant connectivity. However, the strategy has not yet been implemented at any scale, largely due to the significant effort required to configure and calibrate the model used in the MPC controller. While many studies have focused on methods to expedite model configuration and improve model accuracy, few have studied the impact a wide range of factors have on the accuracy of the resulting model. In addition, few have continued on to analyze these factors’ impact on MPC controller performance in terms of final operating costs. Therefore, this study first identifies the practical factors affecting model setup, specifically focusing on the thermal envelope. The seven that are identified are building design, model structure, model order, data set, data quality, identification algorithm and initial guesses, and software tool-chain. Then, through a large number of trials, it analyzes each factor's influence on model accuracy, focusing on grey-box models for a single zone building envelope. Finally, this study implements a subset of the models identified with these factor variations in heating, ventilating, and air conditioning MPC controllers, and tests them in simulation of a representative case that aims to optimally cool a single-zone building with time-varying electricity prices. It is found that a difference of up to 20%25 in cooling cost for the cases studied can occur between the best performing model and the worst performing model. The primary factors attributing to this were model structure and initial parameter guesses during parameter estimation of the model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On the improvement of photovoltaic action of ZnO/P3HT:PCBM by controlling roughness of window layer

Polymer solar cells with configuration ITO/ZnO/P3HT:PCBM/Ag were fabricated using cost effective chemical spray pyrolysis and spin coating techniques. When surface of ZnO layer was modified with a second layer so as to increase the roughness, considerable improvement in cell parameters were observed. Optimum conditions for the required roughness were identified and changes in cell parameters with variation in surface roughness were studied. Major enhancements were observed in the open circuit voltage and in the cell efficiency.

14 SOLAR ENERGY↗

Optimal Configurations for Normal-Metal Traps in Transmon Qubits

Controlling quasiparticle dynamics can improve the performance of superconducting devices. For example, it has been demonstrated effective in increasing the lifetime and stability of superconducting qubits. In this work, we study how to optimize the placement of normal-metal traps in transmon-type qubits. When the trap size increases beyond a certain characteristic length, the details of the geometry and trap position, and even the number of traps, become important. We discuss for some experimentally relevant examples how to shorten the decay time of the excess quasiparticle density. Moreover, we show that a trap in the vicinity of a Josephson junction can significantly reduce the steady-state quasiparticle density near that junction, thus, suppressing the quasiparticle-induced relaxation rate of the qubit. Such a trap also reduces the impact of fluctuations in the generation rate of quasiparticles, rendering the qubit more stable.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Polyelectrolyte Conformation Controlled by a Trivalent-Rich Ion Jacket

The configuration of charged polymers is heavily dependent on interactions with surrounding salt ions, typically manifesting as a sensitivity to the bulk ionic strength. In this work, we use single-molecule mechanical measurements to show that a charged polysaccharide, hyaluronic acid, reflects an interesting regime of insensitivity to ionic strength in the presence of trivalent ions. Using simulations and theory, we propose that this is caused by the formation of a “jacket” of ions, tightly associated with the polymer, whose charge (and thus effect on configuration) is robust against changes in solution composition.

36 MATERIALS SCIENCE↗

Development of near-optimal advanced control sequences for chiller plants with water-side economizers in U.S. Climates (ASHRAE RP-1661)

Various advanced control sequences for chiller plants with water-side economizers (WSE) have been proposed in literature, but the evaluation and optimization of those controls is limited. It is possible to maximize energy savings by selecting different sequences and related parameters based on the plant configuration, load, and climate. This paper addresses this gap by developing near-optimal advanced control sequences for chiller plants with WSEs. First, advanced control sequences for chiller plants with WSEs are categorized into condenser water, chilled water, and hybrid controls and representative sequences from each category are identified. Next, 504 different scenarios are optimized. These scenarios represent all possible combinations of two plant configurations, a constant or variable load profile, three advanced control sequences, and seven optimization parameter combinations in six climate zones. The results show the recommended near-optimal sequences can reduce energy consumption by up to 15% relative to the baseline depending on the configuration, load profile, and climate. Specifically, the CW-CHW sequence is recommended for the majority of systems because it is often the most energy efficient and/or reduces the runtime of chillers. The methodology in this paper provides practical guidance for achieving energy savings through near-optimal control of chiller plants with WSEs.

42 ENGINEERING↗

Remote Deployment and Setup of VOLTTRON Instances

The goal of this project is to increase the pool of people who can install and configure applications in the Intellimation platform. This will be accomplished with a joint development effort between Intellimation and PNNL to create a set of services to simplify the process for the onsite client as well as the Intellimation staff at a centralized location. Intellimation’s tagging capability, hosted in their cloud, will be leveraged to create an autoconfiguration process for selected PNNL applications such as Intelligent Load Control and AIRCX. The results of the configuration process will be sent to Intellimation field units which host the applications locally. This will allow these applications to be configured remotely and with greatly reduced effort on the part of Intellimation staff. Consequently, this will enable a greater usage of these applications and greater impact to energy efficiency than would be possible without this effort. The use of these newly developed services would allow Intellimation to reduce the cost of installation and allow them to offer the service to new and existing clients.

97 MATHEMATICS AND COMPUTING↗

Synchronized operation by field programmable gate array based signal controller for the Thomson scattering diagnostic system in KSTAR

The Thomson scattering diagnostic system is successfully installed in the Korea Superconducting Tokamak Advanced Research (KSTAR) facility. We got the electron temperature and electron density data for the first time in 2011, 4th campaign using a field programmable gate array (FPGA) based signal control board. It operates as a signal generator, a detector, a controller, and a time measuring device. This board produces two configurable trigger pulses to operate Nd:YAG laser system and receives a laser beam detection signal from a photodiode detector. It allows a trigger pulse to be delivered to a time delay module to make a scattered signal measurement, measuring an asynchronous time value between the KSTAR timing board and the laser system injection signal. All functions are controlled by the embedded processor running on operating system within a single FPGA. It provides Ethernet communication interface and is configured with standard middleware to integrate with KSTAR. This controller has operated for two experimental campaigns including commissioning and performed the reconfiguration of logic designs to accommodate varying experimental situation without hardware rebuilding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time sawtooth control and neoclassical tearing mode preemption in ITER

Real-time control of multiple plasma actuators is a requirement in advanced tokamaks; for example, for burn control, plasma current profile control and MHD stabilization—electron cyclotron (EC) wave absorption is ideally suited especially for the latter. On ITER, 24 EC sources can be switched between 56 inputs at the torus. In the torus, 5 launchers direct the power to various locations across the plasma profile via 11 steerable mirrors. For optimal usage of the available power, the aiming and polarization of the beams must be adapted to the plasma configuration and the needs of the scenario. Since the EC system performs many competing tasks, present day systems should demonstrate the ability of an EC plant to deal with several targets in parallel and/or to switch smoothly between goals to attain overall satisfaction. Based on pacing and locking experiments performed on TCV (Tokamak à Configuration Variable), the real-time sawtooth control of ITER with this complex set of actuators is analyzed, as an example. It is shown that sawtooth locking and pacing are possible with various levels of powers, leading to different time delays between the end of the EC power phase and the next sawtooth crash. This timing is important since it allows use of the same launchers for neoclassical tearing mode (NTM) preemption at the q = 1.5 or 2 surface, avoiding the need to switch power between launchers. These options are presented. It is also demonstrated that increasing the total EC power does not necessarily increase the range of control because of the geometry of the launchers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗