Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector Readout”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

ACHILLES-GENIE Interface for Neutrino Simulations, ADRIANO2 Tile Prototype for High-Granularity Dual-Readout Calorimetry

ICARUS (Imaging Cosmic And Rare Underground Signals) is a liquid argon time projection chamber (LArTPC) detector that pursues the sterile neutrino, which relies on accurate simulations of neutrino-argon interactions. REDTOP (Rare Eta Decays To Observe new Physics) is a proposed low-energy, high-intensity meson factory designed to explore rare $\eta$/$\eta'$ meson decays and probe physics beyond the Standard Model. As a next-generation experiment, this requires both accurate simulations and innovative detector technologies. This project contributes to both ICARUS, from a simulation perspective, and REDTOP, from both a simulation and detection perspective, through the event generation of lepton-nucleon interactions and the physical enhancement of the calorimeter technology within the REDTOP detector. We developed an interface between ACHILLES (A CHIcago Land Lepton Event Simulator), a theory-driven lepton-level event generator, and GENIE, a robust event generator framework used for neutrino physics. By incorporating the precise theoretical cross-section calculations of ACHILLES into the experimental realism of GENIE, the interface allows for improved accuracy of neutrino-nucleon simulations, which can be adapted for the proton beam specifications of the REDTOP meson factory as well as for the ICARUS experiment. In parallel, we developed an improved prototype for the ADRIANO2 (A Dual Readout Integrally Active Non-segmented Option) dual-readout calorimeter tiles for the REDTOP detector. To improve the efficiency of the lead-glass tiles trapping Cherenkov light for energy reconstruction and particle identification, we optimized the application of a highly reflective coating. Through viscosity and thickness control, masking, and a custom spray technique, we refined the coating process to reduce surface defects and improve light yield. Together, these efforts strengthen the ICARUS neutrino program and REDTOP's capability of detecting rare decay events.

Visser, Erin [Michigan State U.]↗

Exploring Graphene Field Effect Transistor Devices to Improve Spectral Resolution of Semiconductor Radiation Detectors

Graphene, a planar, atomically thin form of carbon, has unique electrical and material properties that could enable new high performance semiconductor devices. Graphene could be of specific interest in the development of room-temperature, high-resolution semiconductor radiation spectrometers. Incorporating graphene into a field-effect transistor architecture could provide an extremely high sensitivity readout mechanism for sensing charge carriers in a semiconductor detector, thus enabling the fabrication of a sensitive radiation sensor. In addition, the field effect transistor architecture allows us to sense only a single charge carrier type, such as electrons. This is an advantage for room-temperature semiconductor radiation detectors, which often suffer from significant hole trapping. Here we report on initial efforts towards device fabrication and proof-of-concept testing. This work investigates the use of graphene transferred onto silicon and silicon carbide, and the response of these fabricated graphene field effect transistor devices to stimuli such as light and alpha radiation.

36 MATERIALS SCIENCE↗

Operationally induced preferred basis in unitary quantum mechanics

The preferred-basis problem and the definite-outcome aspect of the measurement problem persist even if the detector is modeled unitarily, because experimental data are necessarily represented in a Boolean event algebra of mutually exclusive records whereas the theoretical description is naturally formulated in a noncommutative operator algebra with continuous unitary symmetry. This change of mathematical type constitutes the core of the 'cut': a structurally necessary interface from group-based kinematics to set-based counting. In the presented view the basis relevant for recorded outcomes is not determined by the system Hamiltonian alone; it is induced by the measurement mapping, i.e., by the detector channel together with the coarse-grained readout that defines an instrument. The probabilistic mapping is anchored in symmetry and measure theory: by Gleason-type uniqueness (Gleason for projections in $d>2$ and Busch's extension for Positive Operator-Valued Measures (POVMs) including $d=2$), the trace rule is the unique probability measure consistent with additivity over exclusive events and basis-independence of the unitary sector. A compact qubit--pointer model yields an induced unsharp POVM $E_\pm=\tfrac12(\id\pm η\,σ_z)$ with $η$ fixed by pointer resolution, displaying explicitly how the detector induces the relevant basis. Finally, nested-observer paradoxes are tightened into a non-composability lemma: joint assignment of outcome propositions is obstructed unless a joint instrument exists. This relocates the origin of randomness to the stochasticity of the transition rules.

Pronskikh, Vitaly [Fermilab] (ORCID:00000002518174↗

Performance of the LHCb muon detector in Run 3

In Run 3 of the LHC, the instantaneous luminosity at the LHCb interaction point has been increased by a factor of five, from to $\mathscr{L}$ = 4 x 10 32 cm -2 s -2 to $\mathscr{L}$ = 2 x 10 33 cm -2 s -1 . Several hardware interventions, including a complete overhaul of the readout electronics, have been carried out on the muon detector. The muon identification algorithms in the software trigger were improved with the aim of ensuring Run 2 performance under a higher particle rate. The operation and calibration of the upgraded muon detector are presented. The muon detection efficiency and muon identification performance are evaluated on data calibration samples collected during the year 2024. A muon identification efficiency above 90% with sub-percent hadron misidentification probability is achieved by exploiting the pattern of hits in the muon detector.

Gaseous detectors↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

Heavy Flavor Physics at the sPHENIX Experiment

The sPHENIX experiment is a state-of-the-art jet and heavy flavor physics detector, which successfully recorded its first Au + Au collision data at 200 GeV at the Relativistic Heavy Ion Collider (RHIC). sPHENIX will provide heavy flavor physics measurements at RHIC, covering an unexplored kinematic region and unprecedented precision, to probe the parton energy loss mechanism, parton transport coefficients in quark–gluon plasma, and the hadronization process under various medium conditions. At the center of sPHENIX, the monolithic active pixel sensor (MAPS)-based VerTeX detector (MVTX) is a high-precision silicon pixel detector. The MVTX provides excellent position resolution and the capability of operating in continuous streaming readout mode, allowing precise vertex determination and recording a large data sample, both of which are particularly crucial for heavy flavor physics measurements. In this work, we will show the general performance of heavy-flavor hadron reconstruction. In addition, we will discuss the commissioning experience with sPHENIX. Finally, we will provide the projection of b-hadron and jet observables and discuss the estimated constraints on theoretical models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Compact multiwire proportional counters for the detection of fission fragments

Two large area multistep position sensitive (two dimensional) multiwire proportional counters have been developed for experiments involving study of fission dynamics using general purpose scattering chamber facility at IUAC. Both detectors have an active area of 20x10 cm{sup 2} and provide position signals in horizontal (X) and vertical (Y) planes, timing signal for time of flight measurements and energy signal giving the differential energy loss in the active volume. The design features are optimized for the detection of low energy heavy ions at very low gas pressures. Special care was taken in setting up the readout electronics, constant fraction discriminators for position signals in particular, to get optimum position and timing resolutions along with high count rate handling capability of low energy heavy ions. A custom made charge sensitive preamplifier, having lower gain and shorter decay time, has been developed for extracting the differential energy loss signal. The position and time resolutions of the detectors were determined to be 1.1 mm full width at half maximum (FWHM) and 1.7 ns FWHM, respectively. The detector could handle heavy ion count rates exceeding 20 kHz without any breakdown. Time of flight signal in combination with differential energy loss signal gives a clean separation of fission fragments from projectile and target like particles. The timing and position signals of the detectors are used for fission coincidence measurements and subsequent extraction of their mass, angular, and total kinetic energy distributions. This article describes systematic study of these fission counters in terms of efficiency, time resolution, count rate handling capability, position resolution, and the readout electronics. The detector has been operated with both five electrode geometry and four electrode geometry, and a comparison has been made in their performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Spurious Charge in SENSEI Skipper-CCDs

Skipper Charge-Coupled Devices (Skipper-CCDs) are a leading technology in the search for sub-GeV dark matter and coherent elastic neutrino-nucleus scattering. A key background for rare-event searches with these detectors arises from "spurious charge" -- single-electron events generated when charges are transferred through the active region to the serial register, and across the serial register to the readout stage. We present a characterization of spurious charge in both the active region and the serial register of SENSEI Skipper-CCDs, and show that, in a well-shielded low-background environment, the dominant contribution originates in the serial register during Skipper readout, when horizontal clocks are held at constant voltage between pixel transfers. Motivated by this finding, we develop a "tri-level" clocking scheme in which the held-low phase is raised to an intermediate voltage during readout to suppress trap-mediated charge generation. Using the SENSEI detector near the MINOS cavern, we measure a serial-register single-electron density of $(2.9 \pm 0.1) \times 10^{-5}$ electrons/pixel/image under standard SENSEI readout conditions, reduced to $(4.0 \pm 0.4) \times 10^{-6}$ electrons/pixel/image with tri-level clocking -- a factor of $\sim$7 improvement. This technique offers a promising path to lower backgrounds in current and future Skipper-CCD experiments.

Wu, Yikai [YITP, Stony Brook; SUNY, Stony Brook]↗

Readout system of TPC/MPD NICA project

The time-projection chamber (TPC) is the main tracking detector in the MPD/NICA. The information on charge-particle tracks in the TPC is registered by the MWPG with cathode pad readout. The frontend electronics (FEE) are developed with use of modern technologies such as application specific integrated circuits (ASIC), field-programmable gate arrays (FPGA), and data transfer to a concentrator via a fast optical interface. The main parameters of the FEE are as follows: total number of channels, ∼95 000; data stream from the whole TPC, 5 GB/s; low power consumption, less than 100 mW/ch; signal to noise ratio (S/N), 30; equivalent noise charge (ENC), <1000e{sup –} (C{sub in} = 10–20 pF); and zero suppression (pad signal rejection ∼90%). The article presents the status of the readout chamber construction and the data acquisition system. The results of testing FEE prototypes are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Study of a Mini-Drift GEM Tracking Detector

In this paper, a GEM tracking detector with an extended drift region has been studied as part of an effort to develop new tracking detectors for future experiments at RHIC and for the Electron Ion Collider that is being planned for BNL or JLAB. The detector consists of a triple GEM stack with a 1.6 cm drift region that was operated in a mini TPC type configuration. Both the position and arrival time of the charge deposited in the drift region were measured on the readout plane which allowed the reconstruction of a short vector for the track traversing the chamber. The resulting position and angle information from the vector could then be used to improve the position resolution of the detector for larger angle tracks, which deteriorates rapidly with increasing angle for conventional GEM tracking detectors using only charge centroid information. Two types of readout planes were studied. One was a COMPASS style readout plane with 400 μm pitch XY strips and the other consisted of 2 × 10 mm 2 chevron pads. The detector was studied in test beams at Fermilab and CERN, along with additional measurements in the lab, in order to determine its position and angular resolution for incident track angles up to 45 degrees. Several algorithms were studied for reconstructing the vector using the position and timing information in order to optimize the position and angular resolution of the detector for the different readout planes. Finally, applications for large angle tracking detectors at RHIC and EIC are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

End-to-End Modeling of the TDM Readout System for CMB-S4

The CMB-S4 experiment is developing next-generation ground-based microwave telescopes to observe the cosmic microwave background with unprecedented sensitivity. This will require an order of magnitude increase in the 100-mK detector count, which, in turn, increases the demands on the readout system. The CMB-S4 readout will use time-division multiplexing (TDM), taking advantage of faster switches and amplifiers in order to achieve an increased multiplexing factor. To facilitate the design of the new readout system, we have developed a model that predicts the bandwidth and noise performance of this circuitry and its interconnections. This is then used to set requirements on individual components in order to meet the performance necessary for the full system. Here, we present an overview of this model and compare the model results to the performance of both legacy and prototype readout hardware.

47 OTHER INSTRUMENTATION↗

High-Frequency Gravitational Wave Search with ABRACADABRA-10 cm

ABRACADABRA-10 cm has had great success as a pathfinder lumped-element axion dark matter experiment, setting limits on axion dark matter at the GUT scale. Now, using the interaction of gravitational waves with electrodynamics and a change in readout strategy, we use the ABRA-10 cm detector for the first search for high-frequency gravitational waves using a modified axion detector. Potential sources at these high frequencies (10 kHz to 5 MHz) include merging primordial black hole binaries or superradiance, among other beyond the standard model phenomena. This paper presents the design, results, and challenges from the ABRA-10 cm high-frequency gravitational wave search, showing it is possible to simultaneously look for axions and high-frequency gravitational waves with both searches matching theoretical expectations for sensitivity. Additionally, we conducted the first time series transient search with data from an axion experiment, achieving sensitivity to $10^{-4}$ in strain. Scaled directly to the next generation axion experiment, DMRadio-GUT, this sensitivity would imply a reach to 0.01 $M_{\odot}$ primordial black hole mergers at distances around 3 pc, with prospects to go significantly further with modifications to the readout.

Pappas, Kaliroë M.W. [MIT, LNS] (ORCID:00000003425↗

The Single Event Error (SEE) test and analysis of the CMS Endcap Timing Layer readout chip

The ETROC2, the first full size and full functionality prototype chip for the CMS Endcap Timing Layer readout, is strategically designed to meet the SEE immunity requirements of detector operation with the low power constraint. The triplicated periphery and pixel I2C configuration registers are designed with self-correction feature. The pixel readout control is centralized in the global readout and fully triplicated. The pixel readout is not triplicated, instead protected with power-efficient one-bit correction Hamming code. The TMR protection of the on-pixel threshold calibration can be turned off allowing the detection of the beam spot during the beam test by checking the bit-flips of the internal memory cells. In the initial proton beam test in January 2024, the chip readout process did not hang throughout the tests. The Hamming code correction strategy works because the error corrected TDC data were observed in the data frames. The error-injection simulation is performed to analy ze the small number of bit-flips in the configuration registers. We also performed SEE testing with a heavy ion beam in April and the data analysis is ongoing. The detailed design on the SEE immunity and the testing as well as simulation results will be presented, including follow-up SEE testing results in May and June 2024.

Gong, Datao↗

Development of FELIX based readout system for HV-CMOS sensor testbeam

The High Voltage CMOS (HV-CMOS) sensors are extensively investigated by the ATLAS collaboration for the High-Luminosity LHC (HL-LHC) upgrade of the Inner Tracker (ITk) detector. The HV-CMOS technology is a commercial integrated circuit process with the advantages of monolithic readout and fast charge collection. A front-end test platform of CaRIBOu (Control and Readout Itk BOard) and a testbeam Telescope based on the ATLAS IBL (Insertable B-Layer) silicon pixel modules, have been developed for the HV-CMOS sensor study and characterization in testbeam experiments. The Front-End LInk eXchange (FELIX) system is a newapproach to function as the gateway between detector front-end electronics and the commodity switched network in the ATLAS upgrade. A FELIX based readout system has been developed for both the CaRIBOu and the testbeam Telescope. It has been deployed successfully in the testbeam at theCERNSPS H8 beamline in August 2017. The test results show that the readout system is capable of sensor calibration and readout of a high-density pixel detector with high trigger rate in testbeam experiments.

47 OTHER INSTRUMENTATION↗

A whole-system approach to x-ray spectroscopy in cargo inspection systems

The bremsstrahlung x-ray spectrum used in high-energy, high-intensity x-ray cargo inspection systems is attenuated and modified by the materials in the cargo in a Z-dependent way. Therefore, spectroscopy of the detected x rays yields information about the Z of the x-rayed cargo material. It has previously been shown that such ZSpectroscopy (Z-SPEC) is possible under certain circumstances. A statistical approach, Z-SCAN (Z-determination by Statistical Count-rate ANalysis), has also been shown to be effective, and it can be used either by itself or in conjunction with Z-SPEC when the x-ray count rate is too high for individual x-ray spectroscopy. Both techniques require fast x-ray detectors and fast digitization electronics. It is desirable (and possible) to combine all techniques, including x-ray imaging of the cargo, in a single detector array, to reduce costs, weight, and overall complexity. In this paper, we take a whole-system approach to x-ray spectroscopy in x-ray cargo inspection systems, and show how the various parts interact with one another. Faster detectors and read-out electronics are beneficial for both techniques. A higher duty-factor x-ray source allows lower instantaneous count rates at the same overall x-ray intensity, improving the range of applicability of Z-SPEC in particular. Using an intensity-modulated advanced x-ray source (IMAXS) allows reducing the x-ray count rate for cargoes with higher transmission, and a stacked-detector approach may help material discrimination for the lowest attenuations. Image processing and segmentation allow derivation of results for entire objects, and subtraction of backgrounds. We discuss R and D performed under a number of different programs, showing progress made in each of the interacting subsystems. We discuss results of studies into faster scintillation detectors, including ZnO, BaF{sub 2} and PbWO{sub 4}, as well as suitable photo-detectors, read-out and digitization electronics. We discuss high-duty-factor linear-accelerator x-ray sources and their associated requirements, and how such sources improve spectroscopic techniques. We further discuss how image processing techniques help in correcting for backgrounds and overlapping materials. In sum, we present an integrated picture of how to optimize a cargo inspection system for x-ray spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the directional sensitivity of Dark Matter Time Projection Chamber detectors

The dark matter time projection chamber (DMTPC) is a direction-sensitive detector designed to measure the direction of recoiling 19 F and 12 C nuclei in low-pressure CF 4 gas using optical and charge readout systems. In this paper, we employ measurements from two DMTPC detectors, with operating pressures of 30–60 torr, to develop and validate a model of the directional response and performance of such detectors as a function of recoil energy. Using our model as a benchmark, we formulate the necessary specifications for a scalable directional detector with sensitivity comparable to that of current-generation counting (nondirectional) experiments, which measure only recoil energy. Furthermore assuming the performance of existing DMTPC detectors, as well as current limits on the spin-dependent WIMP-nucleus cross section, we find that a 10–20 kg scale direction-sensitive detector is capable of correlating the measured direction of nuclear recoils with the predicted direction of incident dark matter particles and providing decisive (3σ) confirmation that a candidate signal from a nondirectional experiment was indeed induced by elastic scattering of dark matter particles off of target nuclei.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time resolution of a 1-inch cylindrical CeBr{sub 3} crystal at {sup 60}Co energies

We have measured time resolutions of a cylindrical CeBr{sub 3} scintillator of 1-inch in height and 1-inch in diameter coupled to two different fast photomultiplier tubes, Hamamatsu R9779 and Photonis XP20D0, as a function of applied high voltages and different settings of a Constant Fraction Discriminator ORTEC 935. The time resolution was measured using a time-delayed coincidence set-up involving a fast reference detector. The best result of 119(2) ps at {sup 60}Co energies was obtained for the CeBr{sub 3} crystal coupled to the Hamamatsu PMT. This result is comparable to the resolution of 107 ps reported for a LaBr{sub 3}(Ce) crystal of the same size. For the coupling of the CeBr{sub 3} scintillator to the Photonis PMT we got the time resolution of 146(2) ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring the Nature of Neutrinos with the Deep Underground Neutrino Experiment (DUNE)

The Deep Underground Neutrino Experiment (DUNE) is a next-generation experimental program designed to study the behaviour of neutrino oscillation. DUNE will utilize a neutrino beam originating at Fermilab, near Chicago, and will leverage a detector at Fermilab (Near Detector) and a detector 1300 km away in South Dakota (Far Detector), south of Saskatchewan. In the first phase of DUNE, its Far Detector will comprise of two 10,000 ton (fiducial) liquid argon (LAr) time-projection chamber (TPC) modules – powerful tracking calorimeter detectors – placed nearly a mile underground. With this large, sensitive, underground detector, DUNE aims to collect a high statistics and pure sample of neutrinos at the Far Detector. This setup also offers the potential to study non-beam physical processes via e.g. neutrinos produced in the atmosphere, supernova neutrino bursts, and/or solar neutrinos, etc. A second phase will aim to add more detector mass and expand the program. The Near Detector will consist of a LAr TPC module as well: critical to constraining systematic uncertainties in the oscillation analysis. However, this LAr TPC will have a novel design using a pixel-based readout instead of the traditional wire-based readout. This and the segmentation of the LAr TPC into multiple units are crucial in mitigating the high multiplicity of neutrino interactions expected in any readout window given its proximity to the beam. The Near Detector will feature additional components and capability beyond the LAr TPC, allowing one to deeply characterize the neutrino flux. Due to the complexity of this experimental program, several smaller-scale prototype detectors have been operating to test, validate, and improve both the technical designs and software for processing and analyzing events. By operating in charged particle test beams or neutrino beams, several of the prototypes are also capable of producing valuable results. Canadian institutions are involved in the realization of the DUNE through efforts with both the Near and Far Detectors and prototypes. DUNE is anticipated to begin operating near the end of this decade/the beginning of the next. This talk will focus on the overall DUNE program, for example its ultimate plans, status, and the efforts with prototypes.

Howard, Bruce [York U., Canada; Fermilab]↗