Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital Instrumentation and Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

High-rate x-ray spectroscopy in mammography with a CdTe detector: A digital pulse processing approach

Purpose:Direct measurement of mammographic x-ray spectra under clinical conditions is a difficult task due to the high fluence rate of the x-ray beams as well as the limits in the development of high resolution detection systems in a high counting rate environment. In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate x-ray spectroscopy in mammography. Methods: The DPP system performs a digital pile-up inspection and a digital pulse height analysis of the detector signals, digitized through a 14-bit, 100 MHz digitizer, for x-ray spectroscopy even at high photon counting rates. We investigated on the response of the digital detection system both at low (150 cps) and at high photon counting rates (up to 500 kcps) by using monoenergetic x-ray sources and a nonclinical molybdenum anode x-ray tube. Clinical molybdenum x-ray spectrum measurements were also performed by using a pinhole collimator and a custom alignment device. Results: The detection system shows excellent performance up to 512 kcps with an energy resolution of 4.08% FWHM at 22.1 keV. Despite the high photon counting rate (up to 453 kcps), the molybdenum x-ray spectra, measured under clinical conditions, are characterized by a low number of pile-up events. The agreement between the attenuation curves and the half value layer values, obtained from the measured spectra, simulated spectra, and from the exposure values directly measured with an ionization chamber, also shows the accuracy of the measurements. Conclusions: These results make the proposed detection system a very attractive tool for both laboratory research and advanced quality controls in mammography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feedback lock-in: A versatile multi-terminal measurement system for electrical transport devices

Here, we present the design and implementation of a measurement system that enables parallel drive and detection of small currents and voltages at numerous electrical contacts to a multi-terminal electrical device. This system, which we term a feedback lock-in, combines digital control-loop feedback with software-defined lock-in measurements to dynamically source currents and measure small, pre-amplified potentials. The effective input impedance of each current/voltage probe can be set via software, permitting any given contact to behave as an open-circuit voltage lead or as a virtually grounded current source/sink. This enables programmatic switching of measurement configurations and permits measurement of currents at multiple drain contacts without the use of current preamplifiers. Our 32-channel implementation relies on commercially available digital input/output boards, home-built voltage preamplifiers, and custom open-source software. With our feedback lock-in, we demonstrate differential measurement sensitivity comparable to a widely used commercially available lock-in amplifier and perform efficient multi-terminal electrical transport measurements on twisted bilayer graphene and SrTiO 3 quantum point contacts. The feedback lock-in also enables a new style of measurement using multiple current probes, which we demonstrate on a ballistic graphene device.

47 OTHER INSTRUMENTATION↗

Muon Lifetime Measurement and Introduction to the use of FPGAs in Experimental Physics

During the laboratory sessions at the Workshop, the students used a simple experimental setup to measure the muon lifetime with a 10% statistical error. The muon detector consisted of a sealed container, filled with liquid scintillator, coupled to a 2.5'' photomultiplier (PMT). A personal computer (PC) was used to control a digital oscilloscope which directly measured the time interval between two consecutive PMT pulses in a time window of 20 {mu}s. The students were also introduced to the use of root to analyze the muon data and to measure the muon lifetime. They were also presented with a basic introduction to the application of field-programmable gate arrays (FPGAs) in data acquisition (DAQ) systems by means of examples. We started with a brief introduction to the VHDL language and the software package used to program FPGAs and PROMs on a commercial FPGA development board. They learned to program FPGAs for handling data transfers using the RS-232 port of a PC. They were also introduced to the concepts of circular RAMs (Random Access Memory) and FIFO (First-In First-Out) memories in the context of fast and efficient DAQ systems. We emphasized the way in which inexpensive FPGA-based electronics replaces the use of traditionally used electronics modules, such as NIM, CAMAC, FASTBUS, VME, etc., to construct fast and powerful DAQ systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A servo controlled gradient loading triaxial model test system for deep-buried cavern

A servo controlled gradient loading model test system is developed to simulate the gradient geostress in deep-buried cavern. This system consists of the gradient loading apparatus, the digital servo control device, and the measurement system. Among them, the gradient loading apparatus is the main component which is used for exerting load onto the model. This loading apparatus is placed inside the counterforce wall/beam and is divided to several different loading zones, with each loading zone independently controlled. This design enables the gradient loading. Hence, the “real” geostress field surrounding the deep-buried cavern can be simulated. The loading or unloading process can be controlled by the human-computer interaction machines, i.e., the digital servo control system. It realizes the automation and visualization of model loading/unloading. In addition, this digital servo could control and regulate hydraulic loading instantaneously, which stabilizes the geostress onto the model over a long term. During the loading procedure, the collision between two adjacent loading platens is also eliminated by developing a guide frame. This collision phenomenon is induced by the volume shrinkage of the model when compressed in true 3D state. In addition, several accurate measurements, including the optical and grating-based method, are adopted to monitor the small deformation of the model. Hence, the distortion of the model could be accurately measured. In order to validate the performance of this innovative model test system, a 3D geomechanical test was conducted on a simulated deep-buried underground reservoir. The result shows that the radial convergence increases rapidly with the release of the stress in the reservoir. Moreover, the deformation increases with the increase of the gas production rate. This observation is consistence with field observation in petroleum engineering. The system is therefore capable of testing deep-buried engineering structures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Topographically Induced Thermal Effects on Lunar Hydrogen Distributions: Correlated Observations from the LRO LEND and LOLA Instruments

The question of whether water exists on the Moon's surface has long been an enigma to Lunar researchers. Largely, this was due to the thermally extreme lunar surface environment that would seem to preclude any long term maintenance, manufacture, transport or accumulation of hydrogen (H) volatiles over most of the lunar surface. As a result, for many years the cold permanent shadow regions (PSR) in the bottoms of craters near the lunar poles appeared to provide the basic conditions at least for maintenance of lunar hydrogen. Importantly, recent discoveries indicate that there is some hydrogen at the poles. However, the picture of the lunar hydrogen budget may be more complex than the PSR hypothesis has suggested. This evidence comes from observations by the Lunar Exploration Neutron Detector (LEND) onboard the Lunar Reconnaissance Orbiter (LRO) that inclici1te 1) some H concentrations lie outside PSR and 2) though a few of the larger PSR's have high hydrogen, PSR does not appear to be an independent factor influencing the large-scale suppression of polar epithermals observed by LEND and the Lunar Prospector Neutron Spectrometer. In this research we investigate the possibility that the thermal contrast between pole-facing and equator facing-slopes is a factor influencing the surface distributions of lunar H. We perform this bulk correlated observation and study by developing a thermal proxy from slope data of the Lunar Orbiting Laser Altimeter (LOLA) digital elevation model (DEM) which is registered with the collimated LEND epithermal map. From the LOLA transforms we impose a thermal functional decomposition and systematic statistical analysis of the LEND epithermal map. Our hypothesis testing suggests in most high latitude bands studied> +/- 45 deg: Epithermal rates in pole-facing slopes are significantly lower than epithermal rates in equivalent equator-facing slopes. As a control study, we find that there is no statistically significant difference between equivalent east and west facing slopes. This finding suggests topographic modulation of insolation is a factor influencing the lunar H budget. Importantly, this result is consistent with observations in terrestrial, Martian research.

McClanahan, T. P.↗

Infrared Imaging, Spectroscopic, and Photometric Studies of Comets

We have continued our program of infrared (IR) photometric, imaging, spectroscopic, and polarimetric temporal observations of comets to study the properties of comet dust and comet nuclei. During the first two years we digitized our IR data base on P/Halley and other recent comets to facilitate further analysis and comparison with other data bases, and found compelling evidence for the emission of a burst of small grains from P/Halley's nucleus at perihelion. We reported imaging and photometric observations of Comets Austin 1990 V and Swift-Tuttle 1992. The Swift-Tuttle 1992t observations included IR photometry, several 7-14 micron long-slit spectra of the coma and a time-sequence of more than 150 10 micron broadband images of the coma. An analysis of near-IR images of the inner coma of P/Halley obtained on three consecutive nights in 1986 March showed sunwardjets. We completed our analysis of IR imaging spectrosco-photometric data on comets. We also obtained observations of Comets Hyakutake 1996 B2 and Hale/Bopp 1995 01. We obtained infrared imaging, photometric, spectroscopic and polarimetric temporal observations of bright comets using a network of five telescopes, with emphasis on simultaneous observations of comets at many wavelengths with different instruments. Our program offers several unique advantages: 1) rapid observational response to new comets with dedicated infrared telescopes; 2) observations within a few degrees of the sun when comets are near perihelion and 3) access to advanced infrared array imagers and spectrometers. In particular, reduction, analysis, publication and archiving of our Jupiter/sl-9 and Comet Hyakutake infrared data received special emphasis. Instrumentation development included installation of the latest version of the innovative FORTH telescope control and a data acquisition system that enables us to control three telescopes remotely by telephone from anywhere in the world for comet observations in broad daylight. We have acquired more than 3000 256x256 images totaling nearly two gigabytes of data detailing the near-IR development of the impact sites of the S-L9 fragments on Jupiter. These data were obtained using the University of Rochester Imaging IR Camera at the cassegrain focus of the 92" at WIRO. The WIRO data set covers 8 days and is, to our knowledge, one of the most extensive observational records of the S-L/Jupiter encounter obtained by any ground-based telescope. This program benefitted from the compilation during these last few months of an upgrade to the data acquisition program at WIRO with support of this NASA contract.

Gehrz, Robert D.↗

First results from plasma density measurements in the FTU tokamak by means of a two-frequency pulsed time-of-flight refractometer

A pulsed time-of-flight refractometer was developed and tested to determine the mean plasma density in the T-11M tokamak by measuring the propagation time of nanosecond microwave pulses in plasma. Later, it was also proposed to use such an instrument to measure and control the mean plasma density in the ITER tokamak by probing the plasma with an extraordinary wave, the electric field of which is perpendicular to the magnetic field in plasma, in the transparency window at frequencies of 50-100 GHz. To avoid the effect of the density profile shape on the measurement results in the nonlinear mode of refractometer operation (near the cutoff), a system operating at two different probing frequencies was developed and tested. Such a system provides two values of the time delay, which can be used to estimate the peaking factor of the density distribution {alpha} and correctly determine the linear density Left-Pointing-Angle-Bracket Nl Right-Pointing-Angle-Bracket , regardless of the density profile (assuming a smooth density profile of the form of N({rho}) = N(0)(1 - {rho}{sup 2}){sup {alpha}}, where N(0) is the central plasma density and {rho} = r/a is the normalized plasma radius). The first experiments on density measurements in the FTU tokamak performed with this refractometer are described, and results from these experiments are presented. The formation of a thin dense plasma layer in the zone of a strong magnetic field (the so-called MARFE layer) at a relatively low (for FTU) plasma density of {approx}6 Multiplication-Sign 10{sup 19} m{sup -3} was detected. The thickness of this layer, determined from the refractometry data, agrees well with the data obtained using a digital camera.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Specification of EBR-II Laser Profilometry Data

All laser profilometry data stored in FIPD were originally measured using the element laser profilometer system in HFEF/N. The irradiated fuel elements or pins were scanned by a laser beam to measure the outer diameter with position mapping of the spacer wire. The normal operation and data collection were performed automatically with HFEF/N Data Acquisition and Process Control System (DAPCS). With the digital control system, measured laser profilometry data were recorded in digital form on magnetic tapes, different from the analog contact profilometry data recorded by strip-chart record sheets. Two documents contained most of the important details about laser profilometry measurements. The first one is the operational manual of the laser profilometer (title: Element laser profilometer (ELP) operation and maintenance manual, HFEF/N OMM 4329, DOC. NO. W0171-0149-ES-01). This manual provides: (1) description of laser profilometer including the functions of each component (transceiver, retroreflector, clamping guide, shielding enclosure, electronic controller, etc.); (2) step-by-step guidance for calibrations, operations and measurements; and (3) maintenance procedures and other details of the element laser profilometer. Since first issued on 12/1/1986, several revisions/changes of the manual were developed to update the measurement accuracies and other factors for the laser profilometer system. The second document is a publicly accessible conference article titled “the element laser profilometer system in HFEF/N.” This article summarizes important functions and parameters of the laser profilometer. The range of measurements and the uncertainties reported in the article were consistent with the values reported in the operational manual.

42 ENGINEERING↗

Deployment of a Full-Scope Commercial Nuclear Power Plant Control Room Simulator at the Idaho National Laboratory

The INL operates the HSSL to conduct research in the design and evaluation of advanced reactor control rooms, integration of intelligent support systems to assist operators, development and assessment of advanced human performance models, and visualizations to assess advanced operational concepts across various infrastructures. This advanced facility consists of a reconfigurable simulator and a virtual reality capability (known as the Computer-Aided Virtual Environment (CAVE)) (Figure 2). It supports human factors research, including human-in-the-loop performance, HSI, and analog and digital hybrid control displays. It can be applied to the development and evaluation of control systems and displays for complex systems such as existing and advanced NPP control rooms, command and control systems, and advance emergency operations centers. The HSSL incorporates a reconfigurable control room simulator, which is currently housed in the Center for Advanced Energy Studies (CAES), a joint venture of the DOE and the Idaho University System. The simulator is a platform- and plant-neutral environment intended for full-scope and part-task testing of operator performance in various control room configurations. The simulator is not limited to a particular plant or even simulator architecture. It can support engineering simulator platforms from multiple vendors using digital interfaces. Due to its ability to be reconfigured, it is possible to switch the HSI - not just to digital panels but also to different control modalities such as those using greater plant automation or intelligent alarm filtering. The simulator currently includes three operator workstations, each capable of driving up to eight 30-inch monitors. The size and number of monitors varies depending on the particular front-end simulator deployed for a simulator study. These operator workstations would typically be used for the shift supervisor or senior reactor operator, reactor operator, and assistant reactor operator in current US NPPs. In addition to the three workstations, information can be shared between the workstations and further displayed on a large-screen overview display or a panel mimic. An 82-inch high-definition display is commonly used for the overview display.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Light Water Reactor Sustainability Program: Digital Architecture Project Plan

There are many technologies available to the nuclear power industry to improve efficiency in plant work activities. These range from new control room technologies to those for mobile field workers. They can make a positive impact on a wide range of performance objectives – increase in productivity, human error reduction, validation of results, accurate transfer of data, and elimination of repetitive tasks. It is expected that the industry will more and more turn to these technologies to achieve these operational efficiencies to lower costs. At the same time, this will help utilities manage a looming staffing problem as the inevitable retirement wave of the more seasoned workers affects both staffing levels and knowledge retention. A barrier to this wide-scale implementation of new technologies for operational efficiency is the lack of a comprehensive digital architecture that can support the real-time information exchanges needed to achieve the desired operational efficiencies. This project will define an advanced digital architecture that will accommodate the entire range of system, process, and plant worker activity to enable the highest degree of integration, thereby creating maximum efficiency and productivity. This pilot project will consider a range of open standards that are suitable for the various data and communication requirements of a seamless digital environment. It will map these standards into an overall architecture to support the II&C developments of this research program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ultrafast pixel array camera system and its applications in high energy density physics

Diagnostics in high energy density physics, shock physics, and related fields are primarily driven by a need to record rapidly time-evolving signals in single-shot events. These measurements are often limited by channel count and signal degradation issues on cable links between the detector and digitizer. Here we present the Ultrafast Pixel Array Camera (UPAC), a compact and flexible detector readout system with 32 waveform-recording channels at up to 10 Gsample/s and 1.8 GHz analog bandwidth. The compact footprint allows the UPAC to be directly embedded in the detector environment. A key enabling technology is the PSEC4A chip, an eight-channel switch-capacitor array sampling device with up to 1056 samples/channel. The UPAC system includes a high-density input connector that can plug directly into an application-specific detector board, programmable control, and serial readout, with less than 5 W of power consumption in full operation. We present the UPAC design and characterization, including a measured timing resolution of ~20 ps or better on acquisitions of sub-nanosecond pulses with minimal system calibrations. Example applications of the UPAC are also shown to demonstrate operation of a solid-state streak camera, an ultrafast imaging array, and a neutron time-of-flight spectrometer.

47 OTHER INSTRUMENTATION↗

Digital Twin Framework for the Resilient Remote Monitoring and Operation of Nuclear Microreactors

The nuclear industry is developing new advanced reactor technologies, and many companies are conceptualizing designs for microreactors, a class of nuclear reactor with a sub-20 MWth power output designed to be factory fabricated, easily transportable, and simple to control. Microreactors offer promising solutions to several use cases for which large-scale plants would not be suitable, and conventional power generation means, notably diesel electric generators, are expensive and logistically difficult. Many of the potential use cases are in isolated locations such as arctic communities, remote mines, and military installations. Therefore, the cost of microreactor deployment and traditional onsite operations pose a challenge that requires new technical solutions to address. One solution that has the potential to greatly improve economics is to operate and monitor microreactors remotely from a centralized location. Remote monitoring and operation are novel concepts to the nuclear industry and will greatly alter the tasks and responsibilities associated with current commercial nuclear power plant operators. As such, it is important to perform research on potential technological solutions and the impacts those solutions have on operations with end-goal of defining a safe and effective remote concept of operations. This paper proposes a framework for resilient remote operation of microreactors enabled by a novel digital twin implementation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrating a Microwave Radiometer into Radar Hardware for Simultaneous Data Collection Between the Instruments

The conventional method for integrating a radiometer into radar hardware is to share the RF front end between the instruments, and to have separate IF receivers that take data at separate times. Alternatively, the radar and radiometer could share the antenna through the use of a diplexer, but have completely independent receivers. This novel method shares the radar's RF electronics and digital receiver with the radiometer, while allowing for simultaneous operation of the radar and radiometer. Radars and radiometers, while often having near-identical RF receivers, generally have substantially different IF and baseband receivers. Operation of the two instruments simultaneously is difficult, since airborne radars will pulse at a rate of hundreds of microseconds. Radiometer integration time is typically 10s or 100s of milliseconds. The bandwidth of radar may be 1 to 25 MHz, while a radiometer will have an RF bandwidth of up to a GHz. As such, the conventional method of integrating radar and radiometer hardware is to share the highfrequency RF receiver, but to have separate IF subsystems and digitizers. To avoid corruption of the radiometer data, the radar is turned off during the radiometer dwell time. This method utilizes a modern radar digital receiver to allow simultaneous operation of a radiometer and radar with a shared RF front end and digital receiver. The radiometer signal is coupled out after the first down-conversion stage. From there, the radar transmit frequencies are heavily filtered, and the bands outside the transmit filter are amplified and passed to a detector diode. This diode produces a DC output proportional to the input power. For a conventional radiometer, this level would be digitized. By taking this DC output and mixing it with a system oscillator at 10 MHz, the signal can instead be digitized by a second channel on the radar digital receiver (which typically do not accept DC inputs), and can be down-converted to a DC level again digitally. This unintuitive step allows the digital receiver to sample both the radiometer and radar data at a rapid, synchronized data rate (greater than 1 MHz bandwidth). Once both signals are sampled by the same digital receiver, high-speed quality control can be performed on the radiometer data to allow it to take data simultaneously with the radar. The radiometer data can be blanked during radar transmit, or when the radar return is of a power level high enough to corrupt the radiometer data. Additionally, the receiver protection switches in the RF front end can double as radiometer calibration sources, the short (four-microsecond level) switching periods integrated over many seconds to estimate the radiometer offset. The major benefit of this innovation is that there is minimal impact on the radar performance due to the integration of the radiometer, and the radiometer performance is similarly minimally affected by the radar. As the radar and radiometer are able to operate simultaneously, there is no extended period of integration time loss for the radiometer (maximizing sensitivity), and the radar is able to maintain its full number of pulses (increasing sensitivity and decreasing measurement uncertainty).

McLinden, Matthew↗

Complexity and error potential of digital I and C - 135

Utilization of digital I and C for application in nuclear power plants led to a growing discussion on how to create methods for a probabilistic evaluation on such systems. Issues arise on the one hand due to a lack of commonly accepted models for quantitative evaluation of availability and reliability and on the other hand due to the integration of such models into the evaluation of reliability of an overall system. Nevertheless programmable and even more complex systems are implemented to satisfy growing functionality requirements. Therefore the question for a method to evaluate the reliability of systems based on software or on programmable logic became even more urgent. The approach described is based on the commonly accepted assumption that more complex designs are less reliable. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Acoustic Emission signal acquired by the microphones placed in the CABRI test device along the fourteen last R.I.A. experiments: an example of reproducible research in nuclear science

The CABRI facility is an experimental nuclear reactor of the French Atomic Energy Commission. It is located at the Cadarache Research Centre in southern France and it is designed to act as a support to the French nuclear infrastructure. The purpose of the new testing programme termed, 'CABRI International Programme' (CIP) is to study the behaviour of PWR-type fuel rods at high burnup, equipped with an 'advanced' cladding, under Reactivity Initiated Accident (RIA) conditions (such as the scenario of a control rod ejection). Within the framework of this programme, piloted and funded by the French Institute of Nuclear Radioprotection and Safety (IRSN), ten tests are to be conducted with a frequency of two tests per year. The LPRE laboratory of the CEA which is in charge of the Preparation, realisation and breakdown of the test results studies the possibility to set up a new test analysis based on the processing of signals coming from sensors placed within the test equipment. During the experimental phase, the behaviour of the fuel element generates acoustic waves which can be detected by two microphones placed upstream and downstream of the test device. Studies showed the interest to realize temporal and spectral analyses on these signals by showing the existence of signatures which can be correlated with physical phenomena as the rod failure or the test shutdown (i.e. scram). The work presented in this article results from the will to consolidate these studies. Since the main phenomenon to be tracked is the fuel rod failure, the aim would be to highlight specific events which would have been precursors of the rod failure in order to use in the future these signals for further interpretation. Such an antecedent works resumption leads to a better understanding of the experimental needs and constitutes a good initial state to prepare the new very fast digital data acquisition systems. Although all the raw data are accessible in the form of text files, analyses and graphics representations were not straightforward to reproduce from the ancient studies since that, on one hand, people who were in charge of the original work left the laboratory and on the other hand because it is not easy when the time passes, even with our own work, to be able to remember the steps of data manipulations and the exact setup: - During the ancient experiments the use of analog data acquisition systems required to digitize tapes to be able to realize computer treatments. That had had for consequence to lose the initial dating. This one must be correctly edited to do temporal comparisons. - Analyses require functions for calculations whose parameters has to be well-known to reach the same results. We thus wished to manage our workflow in the idea that it can be easily reproducible on all the experiments. The object of the work presented in this article was to put in practice this strong bind between the data, treatments and generation of the document in order not to hesitate to do the iteration principle in action. We do not have to be afraid by the data driven analyses. According to the philosophy of the literate programming, the text of the technical document is woven with the computer code that produces all the printed output as tables, graphs for the study eliminating hence the unrealistic cut and paste. This difficulty is not specific to the nuclear domain. For many years, researchers have been worked out solutions to this mundane issue. And, presently, new technologies and high-level programming languages offer us actual answers. We will firstly present the tools applied in our laboratory to implement this workflow, then we will describe the global perception carried out to continue the study of the Acoustic Emission signals recorded by the two microphones during the fourteen last CABRI R.I.A. test.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A 15GSa/s, 1.5GHz bandwidth waveform digitizing ASIC

The PSEC4 custom integrated circuit was designed for the recording of fast waveforms for use in large-area time-of-flight detector systems. The ASIC has been fabricated using the IBM-8RF 0.13 micron CMOS process. On each of 6 analog channels, PSEC4 employs a switched capacitor array (SCA) 256 samples deep, a ramp-compare ADC with 10.5 bits of DC dynamic range, and a serial data readout with the capability of region-of-interest windowing to reduce dead time. The sampling rate can be adjusted between 4 and 15 Gigasamples/second [GSa/s] on all channels and is servo-controlled on-chip with a low-jitter delay-locked loop (DLL). The input signals are passively coupled on-chip with a -3 dB analog bandwidth of 1.5 GHz. The power consumption in quiescent sampling mode is less than 50 mW/chip; at a sustained trigger and readout rate of 50 kHz the chip draws 100 mW. After fixed-pattern pedestal subtraction, the uncorrected integral non-linearity is 0.15% over an 750 mV dynamic range. With a linearity correction, a full 1 V signal voltage range is available.The sampling timebase has a fixed-pattern non-linearity with an RMS of 13%, which can be corrected for precision waveform feature extraction and timing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel integrated time-resolved array avalanche photodiode detection system for nuclear resonant scattering measurements

Here, the nuclear resonant scattering (NRS) experiment requires photon-counting detectors with high time resolution, short dead time, large dynamic range, low noise, and large detection area. An 8-channel avalanche photodiode (APD) array detector system with high integrity, flexibility, and reliability has been developed to adapt to the demands of NRS experiments. The detector system mainly consists of four key parts: (i) an array-APD sensor, (ii) 8-channel integrated fast preamplifiers, (iii) the time-to-digital converter readout electronics, and (iv) a data acquisition system and EPICS support software. Remarkably, the system exhibits a time resolution of better than 500 ps and has a sufficiently low noise level, allowing for the lowest detection energy threshold of 4 keV. The performance of the new array-APD system as well as its real application in nuclear forward scattering (NFS) and nuclear resonant inelastic x-ray scattering (NRIXS) experiments was tested in two synchrotron facilities. With the new system, the NFS signal very close to the prompt electronic scattering signal can be extracted. Thanks to the customized EPICS-areaDetector-based control software, NRIXS spectra can be readily measured with time and energy information of the NRIXS signal stored in the raw data, which is promising for developing NRIXS data analysis in the time domain. The array-APD detector can be deployed for nuclear resonant scattering experiments at various synchrotron radiation facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative requirements, stakes and deployment for 2 ongoing major I and C modernization projects (NPIC2017 - 19956) - 293

Rolls-Royce Civil Nuclear I and C is deploying its safety and safety-related technologies in more than 80 plants, in particular in France, China and Finland. This paper gives an overview of the context (including regulatory requirements), stakes, objectives and progress as well as of the technology and technical solutions being deployed in two representative I and C modernization examples: - The modernization of 2 VVER plants in Loviisa (Finland); - Modernization of 20 PWR plants for EDF in France. While there are many similarities: a tight schedule, the cohabitation of new and old systems, mostly from third parties, both digital and analog, and some additional improvements and modifications, the context of these two projects is very different: - Fleet Vs 'isolated' plants approach; - Different types of reactors (PWR Vs VVER); - Involvement of a large utility and Integrator (EDF/Areva) Vs a smaller Utility (Fortum); - Specific safety requirements from well recognized safety authorities (French ASN and Finnish STUK); - Implementation of specific safety functions with the same Safety platform (Rolls-Royce Spinline{sup R}). From this comparison we will extract the main challenges faced, the solutions implemented and some key success factors for such I and C modernizations. In particular: the licensing, the importance of a proven and adaptable safety platform and the often overlooked aspects such as communication and joint working-organization with all the stakeholders: customer, supply chain and safety authorities. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗