Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Photolysis of solid NH{sub 3} and NH{sub 3}-H{sub 2}O mixtures at 193 nm

We have studied UV photolysis of solid ammonia and ammonia-dihydrate samples at 40 K, using infrared spectroscopy, mass spectrometry, and microgravimetry. We have shown that in the pure NH{sub 3} sample, the main species ejected are NH{sub 3}, H{sub 2}, and N{sub 2}, where the hydrogen and nitrogen increase with laser fluence. This increase in N{sub 2} ejection with laser fluence explains the increase in mass loss rate detected by a microbalance. In contrast, for the ammonia-water mixture, we see very weak signals of H{sub 2} and N{sub 2} in the mass spectrometer, consistent with the very small mass loss during the experiment and with a <5% decrease in the NH{sub 3} infrared absorption bands spectroscopy after a fluence of {approx}3 x 10{sup 19} photons/cm{sup 2}. The results imply that ammonia-ice mixtures in the outer solar system are relatively stable under solar irradiation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Origin of stress in radio frequency magnetron sputtered zinc oxide thin films

Highly c-axis oriented ZnO thin films have been deposited on silicon substrates by planar rf magnetron sputtering under varying pressure (10-50 mTorr) and oxygen percentage (50-100%) in the reactive gas (Ar + O{sub 2}) mixture. The as-grown films were found to be stressed over a wide range from -1 x 10{sup 11} to -2 x 10{sup 8} dyne/cm{sup 2} that in turn depends strongly on the processing conditions, and the film becomes stress free at a unique combination of sputtering pressure and reactive gas composition. Raman spectroscopy and photoluminescence (PL) analyses identified the origin of stress as lattice distortion due to defects introduced in the ZnO thin film. FTIR study reveals that Zn-O bond becomes stronger with the increase in oxygen fraction in the reactive gas mixture. The lattice distortion or stress depends on the type of defects introduced during deposition. PL spectra show the formation of a shoulder in band emission with an increase in the processing pressure and are related to the presence of stress. The ratio of band emission to defect emission decreases with the increase in oxygen percentage from 50 to 100%. The studies show a correlation of stress with the structural, vibrational, and photoluminescence properties of the ZnO thin film. The systematic study of the stress will help in the fabrication of efficient devices based on ZnO film.

36 MATERIALS SCIENCE↗

Electroplating hard magnetic SmCo for magnetic microactuator applications

Patterned SmCo thin films were electroplated from an aqueous solute containing glycine by using dc and pulse dc current on the beaker level. Micromolds prepared by photolithography allow an accurate pattern transfer for patterned deposition of the material. A flux guide of a magnetic microactuator was chosen as a pattern, and Al{sub 2}O{sub 3} was used as the substrate. Au and Cr were investigated as seed layer materials. The content of Sm in the SmCo films is strongly dependent on the applied cathodic current density. A relative Sm content of up to 13.8 at. % could be determined by energy dispersive x-ray (EDX) spectroscopy. The SmCo thin films were annealed at 560 deg. C in a vacuum oven. Vibrating sample magnetometer (VSM) measurements were applied to characterize the magnetic properties. This film features hard magnetic properties with an intrinsic coercivity H{sub ci} of up to 44 kA/m. Electron probe microanalysis (EPMA) measurements showed that up to 40 at. % of O may be integrated in these films. The phases in the deposited films were determined by applying X-ray diffraction (XRD) measurements. These films consist of a mixture of SmCo alloy, Sm oxide, and Co.

36 MATERIALS SCIENCE↗

The In-medium Mass and Widths of Light Vector Mesons

Partial restoration of chiral symmetry in ordinary nuclear matter suggests the modification of properties of vector mesons, such as a shift in mass and/or a change of width. Photoproduction of vector mesons off nuclei were performed at Jefferson Lab using the CEBAF Large Acceptance Spectrometer (CLAS). The properties of the {rho}, {omega} and {phi} mesons were investigated via their rare leptonic decay to e+e-. This decay channel has an advantage over hadronic modes as it eliminates final state interactions in the nuclear matter. After subtracting the combinatorial background, the meson mass distributions were extracted for each of the nuclear targets. No significant mass shift is observed, however substantial increase in the widths of the mesons is reported.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved Scintillator Materials for Compact Electron Antineutrino Detectors

Developments in the fields of chemistry and materials science provide new components that hold the potential to improve the performance of liquid scintillation electron antineutrino detectors used for the monitoring of nuclear reactors. New compounds can provide for more efficient, stable, and safer operation of these detectors. Current detectors and their detector materials raise issues regarding size, quantum efficiency, stability, and spatial resolution for the vertex detection. For compact detectors (1 m{sup 3} active volume) improvement of these issues with existing liquid scintillation cocktails can be obtained by means of developing stable and efficient neutron capture agents. These agents comprise of boron or lithium containing coordination compounds, in addition advances in fluorescence detection technologies and optimization of solvent characteristics can improve the overall efficiency. Focus points of the new detector material design are to enable a compact, robust, and direction sensitive electron antineutrino detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Tools For Oilfield Logging-While-Drilling Applications

Schlumberger is an international oilfield service company with nearly 80,000 employees of 140 nationalities, operating globally in 80 countries. As a market leader in oilfield services, Schlumberger has developed a suite of technologies to assess the downhole environment, including, among others, electromagnetic, seismic, chemical, and nuclear measurements. In the past 10 years there has been a radical shift in the oilfield service industry from traditional wireline measurements to logging-while-drilling (LWD) analysis. For LWD measurements, the analysis is performed and the instruments are operated while the borehole is being drilled. The high temperature, high shock, and extreme vibration environment of LWD imposes stringent requirements for the devices used in these applications. This has a significant impact on the design of the components and subcomponents of a downhole tool. Another significant change in the past few years for nuclear-based oilwell logging tools is the desire to replace the sealed radioisotope sources with active, electronic ones. These active radiation sources provide great benefits compared to the isotopic sources, ranging from handling and safety to nonproliferation and well contamination issues. The challenge is to develop electronic generators that have a high degree of reliability for the entire lifetime of a downhole tool. LWD tool testing and operations are highlighted with particular emphasis on electronic radiation sources and nuclear detectors for the downhole environment.

07 ISOTOPE AND RADIATION SOURCES↗

Present and Future of Central Production With STAR Detector at RHIC

The present status and future of the physics program of Central Production using the STAR detector at RHIC are described. The program focuses on particle production in the Double Pomeron Exchange (DPE) process. Forward protons from the DPE interaction are detected in the Roman Pot system installed at 55.5 m and 58.5 m on both sides of the STAR interaction point. The recoil system of charged particles from the DPE process is measured in the STAR Time Projection Chamber (TPC). The first data were taken during the 2009 RHIC Run 9 using polarized proton-proton collisions at {radical}(s) 200 GeV. The preliminary spectra of two pion and four pion invariant mass reconstructed by STAR TPC in central region of pseudo-rapidity |{eta}|<1, are presented. Plans to take data with the current system at {radical}(s) = 500 GeV and plans to upgrade the forward proton tagging system, so that it can reach higher masses and obtain large data samples to allow searching for glueballs that could be produced in the DPE process, are also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Suppression of multipactor discharge on a dielectric surface by an external magnetic field

The multipactor discharge on a dielectric surface in an external magnetic field is simulated by using the particle-in-cell method, and the electron number, energy, the velocity of the yield of secondary electrons, and the power deposited on dielectric surface in the process of multipactor discharge are investigated. The effects of the strength of the external magnetic field on multipactor are studied. The results show that when the external magnetic field reaches a certain value, the multipactor is weaker than that in the case of no external magnetic field and becomes much lighter versus the strength of the external magnetic field in the half microwave period in which the ExB drift pulls the electrons back to dielectric surface. And in the other half microwave period in which the ExB drift pushes the electrons away from the dielectric surface, the multipactor is cut off. So the power capability can be increased to the fourfold by the suppression of multipactor by applying an external magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Meson Spectroscopy at CLAS and CLAS12

We report on meson spectroscopy using the CLAS at Jefferson Lab. We study photo-production of exotic mesons and strangeonia on the largest data sample ever to be produced at photon energies of about 5 GeV. We also describe an experiment to continue meson spectroscopy at CLAS12 (CLAS energy upgrade) using electroproduction at very low Q{sup 2}(''quasireal photons'') up to photon energies of 10 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam emission spectroscopy turbulence imaging system for the MAST spherical tokamak

A new beam emission spectroscopy turbulence imaging system has recently been installed onto the MAST spherical tokamak. The system utilises a high-throughput, direct coupled imaging optics, and a single large interference filter for collection of the Doppler shifted D{sub {alpha}} emission from the {approx}2 MW heating beam of {approx}70 keV injection energy. The collected light is imaged onto a 2D array detector with 8 x 4 avalanche photodiode sensors which is incorporated into a custom camera unit to perform simultaneous 14-bit digitization at 2 MHz of all 32 channels. The array is imaged at the beam to achieve a spatial resolution of {approx}2 cm in the radial (horizontal) and poloidal (vertical) directions, which is sufficient for detection of the ion-scale plasma turbulence. At the typical photon fluxes of {approx}10{sup 11} s{sup -1} the achieved signal-to-noise ratio of {approx}300 at the 0.5 MHz analogue bandwidth is sufficient for detection of relative density fluctuations at the level of a few 0.1%. The system is to be utilised for the study of the characteristics of the broadband, ion-scale turbulence, in particular its interaction with flow shear, as well as coherent fluctuations due to various types of MHD activity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact source for bunches of singly charged atomic ions

We have built, operated, and characterized a compact ion source for low-energy bunches of singly charged atomic ions in a vacuum beam line. It is based on atomic evaporation from an electrically heated oven and ionization by electron impact from a heated filament inside a grid-based ionization volume. An adjacent electrode arrangement is used for ion extraction and focusing by applying positive high-voltage pulses to the grid. The method is particularly suited for experimental environments which require low electromagnetic noise. It has proven simple yet reliable and has been used to produce μs-bunches of up to 10{sup 6} Mg{sup +} ions at a repetition rate of 1 Hz. We present the concept, setup and characterizing measurements. The instrument has been operated in the framework of the SpecTrap experiment at the HITRAP facility at GSI/FAIR to provide Mg{sup +} ions for sympathetic cooling of highly charged ions by laser-cooled {sup 24}Mg{sup +}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ABSOLUTE TIMING OF THE CRAB PULSAR WITH THE INTEGRAL/SPI TELESCOPE

We have investigated the pulse shape evolution of the Crab pulsar emission in the hard X-ray domain of the electromagnetic spectrum. In particular, we have studied the alignment of the Crab pulsar phase profiles measured in the hard X-rays and in other wavebands. To obtain the hard X-ray pulse profiles, we have used six years (2003-2009, with a total exposure of about 4 Ms) of publicly available data of the SPI telescope on-board the International Gamma-Ray Astrophysics Laboratory observatory, folded with the pulsar time solution derived from the Jodrell Bank Crab Pulsar Monthly Ephemeris. We found that the main pulse in the hard X-ray 20-100 keV energy band leads the radio one by 8.18 +- 0.46 milliperiods in phase, or 275 +- 15 mus in time. Quoted errors represent only statistical uncertainties. Our systematic error is estimated to be approx40 mus and is mainly caused by the radio measurement uncertainties. In hard X-rays, the average distance between the main pulse and interpulse on the phase plane is 0.3989 +- 0.0009. To compare our findings in hard X-rays with the soft 2-20 keV X-ray band, we have used data of quasi-simultaneous Crab observations with the proportional counter array monitor on-board the Rossi X-Ray Timing Explorer mission. The time lag and the pulses separation values measured in the 3-20 keV band are 0.00933 +- 0.00016 (corresponding to 310 +- 6 mus) and 0.40016 +- 0.00028 parts of the cycle, respectively. While the pulse separation values measured in soft X-rays and hard X-rays agree, the time lags are statistically different. Additional analysis show that the delay between the radio and X-ray signals varies with energy in the 2-300 keV energy range. We explain such a behavior as due to the superposition of two independent components responsible for the Crab pulsed emission in this energy band.

79 ASTRONOMY AND ASTROPHYSICS↗

PKS 1502+106: A NEW AND DISTANT GAMMA-RAY BLAZAR IN OUTBURST DISCOVERED BY THE FERMI LARGE AREA TELESCOPE

The Large Area Telescope (LAT) on board the Fermi Gamma-ray Space Telescope discovered a rapid ({approx}5 days duration), high-energy (E > 100 MeV) gamma-ray outburst from a source identified with the blazar PKS 1502+106 (OR 103, S3 1502+10, z = 1.839) starting on 2008 August 5 ({approx}23 UTC, MJD 54683.95), and followed by bright and variable flux over the next few months. Results on the gamma-ray localization and identification, as well as spectral and temporal behavior during the first months of the Fermi all-sky survey, are reported here in conjunction with a multiwaveband characterization as a result of one of the first Fermi multifrequency campaigns. The campaign included a Swift ToO (followed up by a 16 day observation on August 7-22, MJD 54685-54700), VLBA (within the MOJAVE program), Owens Valley Radio Observatory (OVRO) 40 m, Effelsberg-100 m, Metsaehovi-14 m, RATAN-600, and Kanata-Hiroshima radio/optical observations. Results from the analysis of archival observations by {integral}, XMM-Newton, and Spitzer space telescopes are reported for a more complete picture of this new gamma-ray blazar. PKS 1502+106 is a sub-GeV peaked, powerful flat spectrum radio quasar (luminosity at E > 100 MeV, L{sub g}amma, is about 1.1 x 10{sup 49} erg s{sup -1}, and black hole mass likely close to 10{sup 9} M{sub sun}), exhibiting marked gamma-ray bolometric dominance, in particular during the asymmetric outburst (L{sub g}amma/L{sub opt} {approx} 100, and 5 day averaged flux F{sub E>100MeV} = 2.91 +- 1.4 x 10{sup -6} ph cm{sup -2} s{sup -1}), which was characterized by a factor greater than 3 of flux increase in less than 12 hr. The outburst was observed simultaneously from optical to X-ray bands (F{sub 0.3-10{sub keV}} = 2.18{sup +0.15}{sub -0.12} x 10{sup -12} erg cm{sup -2} s{sup -1}, and hard photon index {approx}1.5, similar to past values) with a flux increase of less than 1 order of magnitude with respect to past observations, and was likely controlled by Comptonization of external-jet photons produced in the broad-line region (BLR) in the gamma-ray band. No evidence of a possible blue bump signature was observed in the optical-UV continuum spectrum, while some hints for a possible 4 day time lag with respect to the gamma-ray flare were found. Nonetheless, the properties of PKS 1502+106 and the strict optical/UV, X-, and gamma-ray cross-correlations suggest the contribution of the synchrotron self-Compton (SSC), in-jet, process should dominate from radio to X-rays. This mechanism may also be responsible for the consistent gamma-ray variability observed by the LAT on longer timescales, after the ignition of activity at these energies provided by the BLR-dissipated outburst. Modulations and subsequent minor, rapid flare events were detected, with a general fluctuation mode between pink-noise and a random-walk. The averaged gamma-ray spectrum showed a deviation from a simple power law, and can be described by a log-parabola curved model peaking around 0.4-0.5 GeV. The maximum energy of photons detected from the source in the first four months of LAT observations was 15.8 GeV, with no significant consequences on extragalactic background light predictions. A possible radio counterpart of the gamma-ray outburst can be assumed only if a delay of more than three months is considered on the basis of opacity effects at cm and longer wavelengths. The rotation of the electric vector position angle observed by VLBA from 2007 to 2008 could represent a slow field ordering and alignment with respect to the jet axis, likely a precursor feature of the ejection of a superluminal radio knot and the high-energy outburst. This observing campaign provides more insight into the connection between MeV-GeV flares and the moving, polarized structures observed by the VLBI.

79 ASTRONOMY AND ASTROPHYSICS↗

HARD X-RAY EMISSION FROM THE NGC 5044 GROUP

Observations made with the Rossi X-ray Timing Explorer Proportional Counter Array (PCA) to constrain the hard X-ray emission in the NGC 5044 group are reported here. Modeling a combined PCA and ROSAT position sensitive proportional counter spectrum with a 0.5-15 keV energy range shows excess hard emission above 4 keV. Addition of a power-law component with a spectral index of 2.6-2.8 and a luminosity of 2.6 x 10{sup 42} erg s{sup -1} within 700 kpc in the observed energy band removes these residuals. Thus, there is a detection of a significant non-thermal component that is 32% of the total X-ray emission. Point-source emission makes up at most 14% of the non-thermal emission from the NGC 5044 group. Therefore, the diffuse, point-source-subtracted, non-thermal component is (2.2-3.0) x 10{sup 42} erg s{sup -1}. The cosmic-ray electron energy density is 3.6 x 10{sup -12} erg cm{sup -3} and the average magnetic field is 0.034 {mu}G in the largest radio emitting region. The ratio of cosmic-ray electron energy density to magnetic field energy density, {approx}2.5 x 10{sup 4}, is significantly out of equipartition and is therefore atypical of radio lobes. In addition, the group's small size and low non-thermal energy density strongly contradicts the size-energy relationship found for radio lobes. Thus, it is unlikely related to the active galaxy and is most likely a relic of the merger. The energy in cosmic rays and magnetic field is consistent with simulations of cosmic-ray acceleration by merger shocks.

79 ASTRONOMY AND ASTROPHYSICS↗

Synchrotron-radiation-based determination of Xe L-subshell Coster-Kronig yields: A reexamination via high-resolution x-ray spectroscopy

The xenon L-subshell Coster-Kronig (CK) transition yields were revisited via high-resolution measurements of the Lalpha{sub 1,2} (L{sub 3}-M{sub 4,5}) and Lbeta{sub 1} (L{sub 2}-M{sub 4}) x-ray emission lines. The L x-ray spectra were measured employing a Johansson-type curved crystal spectrometer and energy-tunable synchrotron radiation. The CK yields were derived from the relative L x-ray intensity jumps at the L edges by fitting the fluorescence intensities as a function of the photon energy to the L-subshell photoionization cross sections. The latter were obtained from the measured L-edge photoabsorption spectrum. Values of 0.118+-0.029, 0.383+-0.037, and 0.096+-0.016 were found for the f{sub 23}, f{sub 13}, and f{sub 12} CK yields, respectively. Thanks to high resolution, the L{sub 1} fluorescence yield of 0.059+-0.002 was also determined from intensity ratios of the well-resolved Lbeta{sub 4} (L{sub 1}-M{sub 2}) and Lbeta{sub 1} (L{sub 2}-M{sub 4}) lines.

74 ATOMIC AND MOLECULAR PHYSICS↗

Low-energy enhancement in the γ -ray strength functions of Ge 73 , 74

Here, t≤he γ-ray strength functions and level densities of 73,74 Ge have been extracted up to the neutron-separation energy S n from particle-γ coincidence data using the Oslo method. Moreover, the γ-ray strength function of 74 Ge above S n has been determined from photoneutron measurements; hence these two experiments cover the range of Eγ ≈ 1–13 MeV for 74 Ge. The obtained data show that both 73,74 Ge display an increase in strength at low γ energies. The experimental γ-ray strength functions are compared with M1 strength functions deduced from average B(M1) values calculated within the shell model for a large number of transitions. The observed low-energy enhancements in 73,74 Ge are adopted in the calculations of the 72,73 Ge(n,γ) cross sections, where there are no direct experimental data. Calculated reaction rates for more neutron-rich germanium isotopes are shown to be strongly dependent on the presence of the low-energy enhancement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of noncollinear parton dynamics in the prompt photon photoproduction at HERA

We investigate the prompt photon photoproduction at HERA within the framework of the k{sub T}-factorization QCD approach. Our consideration is based on the off-shell matrix elements for the underlying partonic subprocesses. The unintegrated parton densities in a proton and in a photon are determined using the Kimber-Martin-Ryskin prescription. Additionally, we use the Ciafaloni-Catani-Fiorani-Marchesini-evolved unintegrated gluon as well as valence and sea quark distributions in a proton. A conservative error analysis is performed. Both inclusive and associated with the hadronic jet production rates are investigated. The theoretical results are compared with the recent experimental data taken by the H1 and ZEUS Collaborations. We study also the specific kinematical properties of the photon-jet system which are strongly sensitive to the transverse momentum of incoming partons. Using the Kimber-Martin-Ryskin scheme, the contribution from the quarks emerging from the earlier steps of the parton evolution is estimated and found to be of 15%-20% approximately.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Resampling technique to correct for the Doppler effect in a search for gravitational waves

The frequency of any gravitational-wave signal received from a spinning neutron star will appear Doppler-shifted by the Earth's rotation and orbital motion. This frequency shift must be compensated to recover the signal energy as a spectral monochromatic peak with a high signal-to-noise ratio. Generally the correction depends on the source's position in the sky, spin, and spin-down rate. Here we propose a method of applying a single correction to the data which is valid for all the emission frequencies at a fixed position in the sky and for a given spin-down rate. We advance or retard the antenna proper time by removing (or repeating) single samples of the digitized output signal to keep the effective receiver and source clocks in accurate synchronization. The method, which requires just a few lines of code and little computational effort, appears to be very effective for ''semitargeted'' searches, where the source direction is known but the emission frequency is not.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗