Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

The NO$v$A Test Beam Program

NO$\nu$A is a long-baseline off-axis beam neutrino experiment. By measuring $\nu_\mu$ disappearance and $\nu_e$ appearance at the 14 kiloton NO$\nu$A Far Detector, the experiment is addressing outstanding questions in neutrino physics, including the neutrino mass hierarchy and existence of leptonic CP violation. The NO$\nu$A Test Beam program, under deployment at the Fermilab Test Beam Facility, will use a scaled-down NO$\nu$A detector to sample beams of tagged electrons, muons, pions, and protons in the momentum range of 0.3 to 2 GeV/c. It will further the NO$\nu$A physics reach by precisely measuring the detector's muon energy scale and electromagnetic and hadronic response, and provide real data for detailed studies of particle identification techniques. Ongoing efforts on beam-line instrumentation, data acquisition, simulation, momentum reconstruction and particle identification are presented. Implications for the neutrino oscillation measurements are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experiments to Quantify the Shielding Efficacy of Materials to be Implemented for Portable Shielding Enclosures that Adequately Mitigate EMI from Lighting Attachment Events

Mitigating electric and magnetic fields induced by lightning strike events is critical for the security and longevity of electrical components. Electromagnetic interference originating from a lightning strike is categorized into the low to medium frequency ranges, commonly referred to as the “magnetic coupling” regime. This low-frequency characteristic brings about the problem of shielding magnetic flux lines. Such shielding can be accomplished with highly conductive materials via the generation of eddy currents or by diverting the flux lines using materials with a large relative permeability. The shielding effectiveness of materials with varying thicknesses and geometry are tested using a pulse forming network having comparable characteristics to a scaled lighting strike. A four-stage Marx generator with a peak current of ~33 kA and a risetime of 1.4 μs is used as the pulse forming network to emulate the scaled electric and magnetic fields. The data collected from these experiments provide information and techniques that can be implemented into the design of a portable, deployable shielding enclosure.

61 RADIATION PROTECTION AND DOSIMETRY↗

Inferences on mass composition and tests of hadronic interactions from 0.3 to 100 EeV using the water-Cherenkov detectors of the Pierre Auger Observatory

We present a new method for probing the hadronic interaction models at ultra-high energy and extracting details about mass composition. This is done using the time profiles of the signals recorded with the water-Cherenkov detectors of the Pierre Auger Observatory. The profiles arise from a mix of the muon and electromagnetic components of air-showers. Using the risetimes of the recorded signals we define a new parameter, which we use to compare our observations with predictions from simulations. We find, firstly, inconsistencies between our data and predictions over a greater energy range and with substantially more events than in previous studies. Secondly, by calibrating the new parameter with fluorescence measurements from observations made at the Auger Observatory, we can infer the depth of shower maximum for a sample of over 81,000 events extending from 0.3 EeV to over 100 EeV. Above 30 EeV, the sample is nearly fourteen times larger than currently available from fluorescence measurements and extending the covered energy range by half a decade. The energy dependence of the average depth of shower maximum is compared to simulations and interpreted in terms of the mean of the logarithmic mass. Here, we find good agreement with previous work and extend the measurement of the mean depth of shower maximum to greater energies than before, reducing significantly the statistical uncertainty associated with the inferences about mass composition.

79 ASTRONOMY AND ASTROPHYSICS↗

Adaptive model order reduction for the Jacobian calculation in inverse multi-frequency problem for Maxwell's equations

Here this work develops a model order reduction method for a numerical solution of an inverse multi-frequency eddy current problem using a rational interpolation of the transfer function in the complex plane. We use the Pade interpolation in the complex frequency plane; this allows us to speed up the calculation of the frequency-dependent Jacobian in the inversion procedure without loosing accuracy. Interpolating frequencies are chosen adaptively to reduce the maximal approximation error. We use the error indicator that is equivalent to a seminorm of the residual. The efficiency of the developed approach is demonstrated by applying it to the inverse magnetotelluric problem, which is a geophysical electromagnetic remote sensing method used in mineral, geothermal, and groundwater exploration. In this application, the transfer function values are needed for shifts in a purely imaginary interval. Thus we consider the interpolating shifts in the same interval as well as in a purely real interval, containing the spectrum of the operator. Numerical tests show an excellent performance of the proposed methods characterized by a significant reduction of computational time without loss of accuracy of the calculated Jacobian.

97 MATHEMATICS AND COMPUTING↗

Low-loss negative index metamaterials for X, Ku, and K microwave bands

Low-loss, negative-index of refraction metamaterials were designed and tested for X, Ku, and K microwave frequency bands. An S-shaped, split-ring resonator was used as a unit cell to design homogeneous slabs of negative-index metamaterials. Then, the slabs of metamaterials were cut unto prisms to measure experimentally the negative index of refraction of a plane electromagnetic wave. Theoretical simulations using High-Frequency Structural Simulator, a finite element equation solver, were in good agreement with experimental measurements. The negative index of refraction was retrieved from the angle- and frequency-dependence of the transmitted intensity of the microwave beam through the metamaterial prism and compared well to simulations; in addition, near-field electromagnetic intensity mapping was conducted with an infrared camera, and there was also a good match with the simulations for expected frequency ranges for the negative index of refraction.

36 MATERIALS SCIENCE↗

Double side read-out technique for mitigation of radiation damage effects in PbWO 4 crystals

Test beam results of a calorimetric module based on 3×3×22 cm 3 PbWO 4 crystals, identical to those used in the CMS ECAL Endcaps, read out by a pair of photodetectors coupled to the two opposite sides (front and rear) of each crystal are presented. Nine crystals with different level of induced absorption, from 0 to 20 m -1 , have been tested using electrons in the 50–200 GeV energy range. Photomultiplier tubes have been chosen as photodetectors to allow for a precise measurement of highly damaged crystals. The information provided by this double side read-out configuration allows to correct for event-by-event fluctuations of the longitudinal development of electromagnetic showers. By strongly mitigating the effect of non-uniform light collection efficiency induced by radiation damage, the double side read-out technique significantly improves the energy resolution with respect to a single side read-out configuration. The non-linearity of the response arising in damaged crystals is also corrected by a double side read-out configuration and the response linearity of irradiated crystals is restored. In high radiation environments at future colliders, as it will be the case for detectors operating during the High Luminosity phase of the Large Hadron Collider, defects can be created inside the scintillator volume leading to a non-uniform response of the calorimetric cell. As a result, the double side read-out technique presented in this study provides a valuable way to improve the performance of calorimeters based on scintillators whose active volumes are characterized by high aspect ratio cells similar to those used in this study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-AB-201-03: A Robot for the Automated Delivery of An Electromagnetic Tracking Sensor for the Localization of Brachytherapy Catheters

Purpose: To present a programmable robotic system for the accurate and fast deployment of an electromagnetic (EM) sensor for brachytherapy catheter localization. Methods: A robotic system for deployment of an EM sensor was designed and built. The system was programmed to increment the sensor position at specified time and space intervals. Sensor delivery accuracy was measured in a phantom using the localization of the EM sensor and tested in different environmental conditions. Accuracy was tested by measuring the distance between the physical locations reached by the sensor (measured by the EM tracker) and the intended programmed locations. Results: The system consisted of a stepper motor connected to drive wheels (that grip the cable to move the sensor) and a series of guides to connect to a brachytherapy transfer tube, all controlled by a programmable Arduino microprocessor. The total cost for parts was <$300. The positional accuracy of the sensor location was within 1 mm of the expected position provided by the motorized guide system. Acquisition speed to localize a brachytherapy catheter with 20 cm of active length was 10 seconds. The current design showed some cable slip and warping depending on environment temperature. Conclusion: The use of EM tracking for the localization of brachytherapy catheters has been previously demonstrated. Efficient data acquisition and artifact reduction requires fast and accurate deployment of an EM sensor in consistent, repeatable patterns, which cannot practically be achieved manually. The design of an inexpensive, programmable robot allowing for the precise deployment of stepping patterns was presented, and a prototype was built. Further engineering is necessary to ensure that the device provides efficient independent localization of brachytherapy catheters. This research was funded by the Kaye Family Award.

60 APPLIED LIFE SCIENCES↗

Summary: SEE4GEO

The seismoelectric effects technique (SEE) is a new and innovative approach for geothermal subsurface imaging and monitoring at reservoir scale. The objective of this project is to assess SEE in terms of data acquisition, cost and quality, and to determine its capability in comparison with classical imaging and monitoring techniques, particularly decoupled seismic and electromagnetic methods. This will be achieved by (1) development of a fast, true 3D numerical package, handling SEE imaging and subsurface properties characterization, including resistivity and permeability, (2) laboratory experiments performed in a controlled environment to define optimal deployment design, data quality, and inform field deployment, and (3) field surveys to ultimately test and draw lessons for practical use of SEE technology. There is a relatively extensive body of work in the literature on SEE, and members of this consortium have been involved in theoretical and numerical development of SEE modeling as well as laboratory experiments. Nevertheless, to our knowledge few, if any, documented efforts have been specifically targeting the use of SEE for geothermal subsurface imaging and monitoring. The strength and originality of our proposal rely on an integrated approach leveraging numerical, laboratory and field experiments, to properly document the practical use of SEE. Through this process, SEE in-hand technology for the geothermal industry will be able to progress from a TRL 1 to TRL 3.

58 GEOSCIENCES↗

Seismoelectric Effects for Geothermal Resources Assessment and Monitoring (SEE4GEO)

The seismoelectric effects technique (SEE) is a new and innovative approach for geothermal subsurface imaging and monitoring at reservoir scale. The objective of this project is to assess SEE in terms of data acquisition, cost and quality, and to determine its capability in comparison with classical imaging and monitoring techniques, particularly decoupled seismic and electromagnetic methods. This will be achieved by (1) development of a fast, true 3D numerical package, handling SEE imaging and subsurface properties characterization, including resistivity and permeability, (2) laboratory experiments performed in a controlled environment to define optimal deployment design, data quality, and inform field deployment, and (3) field surveys to ultimately test and draw lessons for practical use of SEE technology. There is a relatively extensive body of work in the literature on SEE, and members of this consortium have been involved in theoretical and numerical development of SEE modeling as well as laboratory experiments. Nevertheless, to our knowledge few, if any, documented efforts have been specifically targeting the use of SEE for geothermal subsurface imaging and monitoring. The strength and originality of our proposal rely on an integrated approach leveraging numerical, laboratory and field experiments, to properly document the practical use of SEE. Through this process, SEE in-hand technology for the geothermal industry will be able to progress from a TRL 1 to TRL 3.

58 GEOSCIENCES↗

Dual Readout in Homogenous Inorganic Scintillators for Precision Calorimeters

Homogeneous inorganic scintillator-based calorimeters are the gold standard for electromagnetic energy resolution, but often degrade the hadronic energy resolution achievable at colliders. By incorporating the dual readout technique, we seek to improve the hadronic energy resolution of these calorimeters through the measurement and separation of the scintillation and Cherenkov light in hadronic showers. In April 2024, CalVision performed single-crystal tests using the electron test beam at DESY. Using a single delay line technique for waveform analysis, sufficient cerenkov light can be extracted to fully capitalize on the dual readout technique. This talk will present the results of PWO, BGO, BSO, PbF2, and two novel scintillating glasses.

Anderson, Thomas [Virginia U.]↗

Insights Gained for Updating an Analog I&C System to a Digital System

Licensees at both Nuclear Power Plants (NPPs) and Non-Power Reactors (NPRs) are increasing their use of state-of-the-art digital technology in instrumentation and control (I&C) systems because digital systems offer improved reactor control, information processing, and information storage over analog. Digital I&C systems can range from experimental systems for reactor control research (at NPRs), to measurement and display systems, to complete reactor console replacements. Because of the increasing difficulty in finding spare parts for their original analog I&C systems, many licensees have begun or have plans to upgrade, refurbish, or replace their old analog I&C systems with digital systems. The perception is that upgrading to a digital I&C system will solve all of a facility s obsolescence problems. However, licensees need to be aware of several issues associated with upgrading to a digital system including obsolescence of the digital system (hardware and software) because of the short product life cycle and the associated cost to acquire, store, and maintain a long-term supply of spare parts. Configuration management and cyber security are also vitally important for any upgrade. Further, it must be recognized that the introduction of software and microprocessors could create new failure mechanisms, such as software errors and increased susceptibility to electromagnetic interference. In fact, experience has shown that these failure mechanisms may cause the reactor to malfunction in a way not previously considered. Thus, a conversion from analog to digital I&C systems solves some problems while potentially introducing others. Recognition of the additional risks coupled with good design, engineering, review, and testing can identify and minimize these risks.

Adams, A.↗

The performance of the LHCf detector

The LHCf experiment is designed to measure energies and transverse momenta of neutral particles emitted in the forward region of {radical}(s) = 14 TeV p-p collision at {+-}140 m away from the interaction point1 (IP1) of LHC. The energy resolution is confirm to be within 5% and the position resolution is better than 0.2 mm for gamma-rays with energies from 100 GeV to 200 GeV by the test beam results at the CERN-SPS. LHCf has taken data at 2009 and 2010 at {radical}(s) = 900 GeV and 7 TeV collision. A brief summary of LHCf operation at LHC is also reported here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing modifications of general relativity using current cosmological observations

We test general relativity (GR) using current cosmological data: the CMB from WMAP5 [E. Komatsu et al. (WMAP Collaboration), Astrophys. J. Suppl. Ser. 180, 330 (2009)], the integrated Sachs-Wolfe (ISW) effect from the cross correlation of the CMB with six galaxy catalogs [T. Giannantonio et al., Phys. Rev. D 77, 123520 (2008)], a compilation of supernovae (SNe) type Ia including the latest Sloan Digital Sky Survey SNe [R. Kessler et al., Astrophys. J. Suppl. Ser. 185, 32 (2009).], and part of the weak lensing (WL) data from the Canada-Franco-Hawaii Telescope Legacy Survey [L. Fu et al., Astron. Astrophys. 479, 9 (2008); M. Kilbinger et al., Astron. Astrophys. 497, 677 (2009).] that probe linear and mildly nonlinear scales. We first test a model in which the effective Newtonian constant {mu} and the ratio of the two gravitational potentials, {eta}, transit from the GR value to another constant at late times; in this case, we find that GR is fully consistent with the combined data. The strongest constraint comes from the ISW effect which would arise from this gravitational transition; the observed ISW signal imposes a tight constraint on a combination of {mu} and {eta} that characterizes the lensing potential. Next, we consider four pixels in time and space for each function {mu} and {eta}, and perform a principal component analysis, finding that seven of the resulting eight eigenmodes are consistent with GR within the errors. Only one eigenmode shows a 2{sigma} deviation from the GR prediction, which is likely to be due to a systematic effect. However, the detection of such a deviation demonstrates the power of our time- and scale-dependent principal component analysis methodology when combining observations of structure formation and expansion history to test GR.

79 ASTRONOMY AND ASTROPHYSICS↗

Vacuum electromagnetic counterparts of binary black-hole mergers

As one step towards a systematic modeling of the electromagnetic (EM) emission from an inspiralling black hole binary we consider a simple scenario in which the binary moves in a uniform magnetic field anchored to a distant circumbinary disc. We study this system by solving the Einstein-Maxwell equations in which the EM fields are chosen with strengths consistent with the values expected astrophysically and treated as test fields. Our initial data consists of a series of binaries with spins aligned or antialigned with the orbital angular momentum and we study the dependence of gravitational and EM signals with different spin configurations. Overall we find that the EM radiation in the lowest l=2, m=2 multipole accurately reflects the gravitational one, with identical phase evolutions and amplitudes that differ only by a scaling factor. This is no longer true when considering higher l modes, for which the amplitude evolution of the scaled EM emission is slightly larger, while the phase evolutions continue to agree. We also compute the efficiency of the energy emission in EM waves and find that it scales quadratically with the total spin and is given by E{sub EM}{sup rad}/M{approx_equal}10{sup -15}(M/10{sup 8}M{sub {center_dot}}){sup 2}(B/10{sup 4}G){sup 2}, hence 13 orders of magnitude smaller than the gravitational energy for realistic magnetic fields. Although large in absolute terms, the corresponding luminosity is much smaller than the accretion luminosity if the system is accreting at near the Eddington rate. Most importantly, this EM emission is at frequencies of {approx}10{sup -4}(10{sup 8}M{sub {center_dot}}/M) Hz, which are well outside those accessible to astronomical radio observations. As a result, it is unlikely that the EM emission discussed here can be detected directly and simultaneously with the gravitational-wave one. However, indirect processes, driven by changes in the EM fields behavior could yield observable events. In particular we argue that if the accretion rate of the circumbinary disc is small and sufficiently stable over the timescale of the final inspiral, then the EM emission may be observable indirectly as it will alter the accretion rate through the magnetic torques exerted by the distorted magnetic field lines.

79 ASTRONOMY AND ASTROPHYSICS↗

Experiment for testing special relativity theory

An experiment aimed at testing special relativity via a comparison of the velocity of a nonmatter particle (annihilation photon) with the velocity of the matter particle (Compton electron) produced by the second annihilation photon from the decay {sup 22}Na ({beta}+){sup 22}Ne is proposed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum calculations of the cavity shift in electron magnetic moment measurements

The measurement of the anomalous electron magnetic moment g – 2 through quantum transitions of a single trapped electron is the most stringent test of quantum field theory. These experiments are now so precise that they must account for the effects of the cavity containing the electron. Classical calculations of this “cavity shift” must subtract the electron’s divergent self-field, and thus require knowledge of the exact Green’s function for the cavity’s electromagnetic field. We perform the first fully quantum calculation of the cavity shift in a closed cavity, which instead involves subtracting linearly divergent cavity mode sums and integrals. Using contour integration methods, we find perfect agreement with existing classical results for both spherical and cylindrical cavities, justifying their current use. Moreover, our mode-based results can be naturally generalized to account for systematic effects, necessary to push future measurements to the next order of magnitude in precision.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Millicharged relics reveal massless dark photons

The detection of massless kinetically-mixed dark photons is notoriously difficult, as the effect of this mixing can be removed by a field redefinition in vacuum. In this work, we study the prospect of detecting massless dark photons in the presence of a cosmic relic directly charged under this dark electromagnetism. Such millicharged particles, in the form of dark matter or dark radiation, generate an effective dark photon mass that drives photon-to-dark photon oscillations in the early universe. We also study the prospect for such models to alleviate existing cosmological constraints on massive dark photons, enlarging the motivation for direct tests of this parameter space using precision terrestrial probes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗