Search NASA⌕ Search

SEARCH · Search NASA

Results for “Failure Modes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Analysis and design of advanced composite bounded joints

Advances in the analysis of adhesive-bonded joints are presented with particular emphasis on advanced composite structures. The joints analyzed are of double-lap, single-lap, scarf, stepped-lap and tapered-lap configurations. Tensile, compressive, and in-plane shear loads are covered. In addition to the usual geometric variables, the theory accounts for the strength increases attributable to adhesive plasticity (in terms of the elastic-plastic adhesive model) and the joint strength reductions imposed by imbalances between the adherends. The solutions are largely closed-form analytical results, employing iterative solutions on a digital computer for the more complicated joint configurations. In assessing the joint efficiency, three potential failure modes are considered. These are adherend failure outside the joint, adhesive failure in shear, and adherend interlaminar tension failure (or adhesive failure in peel). Each mode is governed by a distinct mathematical analysis and each prevails throughout different ranges of geometric sizes and proportions.

Hart-Smith, L. J.↗

Digital I and C system upgrade integration technique

This work developed an integration technique for digital I and C system upgrade, the utility can replace the I and C systems step by step systematically by this method. Inst. of Nuclear Energy Research (INER) developed a digital Instrumentation and Control (I and C) replacement integration technique on the basis of requirement of the three existing nuclear power plants (NPPs), which are Chin-Shan (CS) NPP, Kuo-Sheng (KS) NPP, and Maanshan (MS) NPP, in Taiwan, and also developed the related Critical Digital Review (CDR) Procedure. The digital I and C replacement integration technique includes: (I) Establishment of Nuclear Power Plant Digital Replacement Integration Guideline, (2) Preliminary Investigation on I and C System Digitalization, (3) Evaluation on I and C System Digitalization, and (4) Establishment of I and C System Digitalization Architectures. These works can be a reference for performing I and C system digital replacement integration of the three existing NPPs of Taiwan Power Company (TPC). A CDR is the review for a critical system digital I and C replacement. The major reference of this procedure is EPRI TR- 1011710 (2005) 'Handbook for Evaluating Critical Digital Equipment and Systems' which was published by the Electric Power Research Inst. (EPRI). With this document, INER developed a TPC-specific CDR procedure. Currently, CDR becomes one of the policies for digital I and C replacement in TPC. The contents of this CDR procedure include: Scope, Responsibility, Operation Procedure, Operation Flow Chart, CDR review items. The CDR review items include the comparison of the design change, Software Verification and Validation (SVandV), Failure Mode and Effects Analysis (FMEA), Evaluation of Diversity and Defense-in-depth (D3), Evaluation of Watchdog Timer, Evaluation of Electromagnetic Compatibility (EMC), Evaluation of Grounding for System/Component, Seismic Evaluation, Witness and Inspection, Lessons Learnt from the Digital I and C Failure Events. A solid review can assure the quality of the digital I and C system replacement. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Reliability Assessment of Cooling Fans for PV Inverters: Testing, Modeling, and Case Studies

The reliability of photovoltaic (PV) inverters is critical for long-term solar system performance, with cooling fan failures frequently leading to costly downtime. While much research exists on general cooling fan reliability, little attention has been given to fans operating within PV inverters and their unique environmental challenges. Here, this article proposes a comprehensive methodology to address this gap. First, a failure mode and effects analysis is performed on fans to identify the key failure mechanisms in PV applications, their corresponding stressors, and the models necessary for lifetime prediction. Second, an accelerated life test is designed and conducted to collect valuable experimental data for PV inverter fans in a reasonable amount of time. Third, a mathematical conversion of dynamic mission profiles into effective constant stress levels is derived. Fourth, case studies are given, showcasing lifetime estimates that account for geographic variations in mission profile data. The results demonstrate that this integrated approach leads to an accurate reliability assessment for PV inverter cooling fans.

accelerated life testing (ALT)↗

Filament-reinforced metal composite pressure vessel evaluation and performance demonstration

Two different Kevlar-49 filament-reinforced metal sphere designs were developed, and six vessels of each type were fabricated and subjected to fatigue cycling, sustained loading, and hydrostatic burst. The 61 cm (24 inch) diameter Kevlar-49/cryoformed 301 stainless steel pressure vessels demonstrated the required pressure cycle capability, burst factor of safety, and a maximum pressure times volume divided by weight (pV/W) performance of 210 J/g (834 000 in-lb/lbm) at burst; this represented a 25 to 30% weight saving over the lightest weight comparable, 6A1-4V Ti, homogeneous pressure vessel. Both the Kevlar/stainless steel design and the 97 cm (38 inch) diameter Kevlar-49/2219-T62 aluminum sphere design demonstrated nonfragmentation and controlled failure mode features when pressure cycled to failure at operating pressure. When failure occurred during pressure cycling, the mode was localized leakage and not catastrophic. Kevlar/stainless steel vessels utilized a unique conical boss design, and Kevlar/aluminum vessels incorporated a tie-rod to carry port loads; both styles of polar fittings performed as designed during operational testing of the vessels.

Landes, R. E.↗

Failure Mechanisms of Hollow Fiber Supported Ionic Liquid Membranes

Hollow fiber supported ionic liquid membranes (SILMs) were tested using the bubble point method to investigate potential failure modes, including the maximum transmembrane pressure before loss of the ionic liquid from the support. Porous hollow fiber supports were fabricated with different pore morphologies using Matrimid® and Torlon® as the polymeric material and 1-hexyl-3-methylimidalzolium bis(trifluoromethylsulfonyl)imide ([C6mim][Tf2N]) as the ionic liquid (IL) component. Hollow fiber SILMs were tested for their maximum pressure before failure, with pressure applied either from the bore side or shell side. It was found that the membranes exhibited one or more of three different modes of failure when pressurized: liquid loss (occurring at the bubble point), rupture, and collapse.

rupture↗

Dynamic properties of FeCrMnNi, a high entropy alloy

The goal of this paper was to assess the dynamic properties of a new class of materials, High entropy alloys (HEAs). Specifically, gas gun experiments coupled with recovery were performed on a specific HEA, FeCrMnNi, to measure its equation of state (EOS) and its spall strength, which is a measure of the stress required to nucleate voids under shock loading conditions. While there has been a plethora of work performed to assess the mechanical properties of these HEAs under uniaxial stress conditions as a function of strain rate, investigation of its properties in dynamic extremes remains rare. The current work fills this gap in knowledge for this novel class of materials. Our results show that the measured EOS for this material at one velocity was in reasonable agreement with an estimated Hugoniot. Furthermore, while the spall strength for this material was found to be ~1.9 GPa, with some variation based on sample location, the main failure mode was brittle. This brittle failure leading to formation of cracks in the material is different than the ductile failure observed in pure iron and its alloys.

36 MATERIALS SCIENCE↗

Shock-induced twinning/detwinning and spall failure in Cu–Ta nanolaminates at atomic scales

Here, this study provides new insights into the role of interfaces on the deformation and failure mechanisms in shock-loaded Cu–Ta–Cu trilayer system. The thickness of the Ta layer, piston velocities, and shock pulse durations were varied to explore the impact of impedance mismatch and loading conditions on spallation behavior and twin formation. It was found that the interfaces play a crucial role in the dynamic response of these multilayered systems since secondary reflection waves generated at the interfaces significantly affected the peak stress and pressure profiles, influencing void nucleation and failure modes. In the trilayer systems, failure predominantly occurred at interfaces and within the Ta layer, with void nucleation sites and twinning behavior being markedly different compared to single-crystal Cu and Ta. Increasing the Ta layer thickness modified the wave interactions, leading to different failure locations. Higher piston velocities were associated with increased spall strength by enhancing wave interactions and void formation, particularly at the interfaces and within the Ta layer, under specific configurations. Additionally, shorter shock pulse durations facilitated earlier initiation of the release fan, reducing twin formation and altering the failure dynamics by accelerating twin annihilation and pressure release.

36 MATERIALS SCIENCE↗

SU-F-R-12: Prediction of TrueBeam Hardware Issues Using Trajectory Log Analysis

Purpose: To predict potential failures of hardware within the Varian TrueBeam linear accelerator in order to proactively replace parts and decrease machine downtime. Methods: Machine downtime is a problem for all radiation oncology departments and vendors. Most often it is the result of unexpected equipment failure, and increased due to lack of in-house clinical engineering support. Preventative maintenance attempts to assuage downtime, but often is ineffective at preemptively preventing many failure modes such as MLC motor failures, the need to tighten a gantry chain, or the replacement of a jaw motor, among other things. To attempt to alleviate downtime, software was developed in house that determines the maximum value of each axis enumerated in the Truebeam trajectory log files. After patient treatments, this data is stored in a SQL database. Microsoft Power BI is used to plot the average maximum error of each day of each machine as a function of time. The results are then correlated with actual faults that occurred at the machine with the help of Varian service engineers. Results: Over the course of six months, 76,312 trajectory logs have been written into the database and plotted in Power BI. Throughout the course of analysis MLC motors have been replaced on three machines due to the early warning of the trajectory log analysis. The service engineers have also been alerted to possible gantry issues on one occasion due to the aforementioned analysis. Conclusion: Analyzing the trajectory log data is a viable and effective early warning system for potential failures of the TrueBeam linear accelerator. With further analysis and tightening of the tolerance values used to determine a possible imminent failure, it should be possible to pinpoint future issues more thoroughly and for more axes of motion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Protection Instrument Reliability and Maintainability Data

This report is a collection of reliability and maintenance data on several types of radiation protection instrumentation. Some radiation detectors are used for personnel safety; others are used for environmental stewardship. Six types of instruments are addressed in this report. These are: continuous air monitors, tritium room air monitors, facility vent stack monitors, tritium bubbler monitors, tritium in effluent water monitors, and general purpose radiation survey meters. Literature searches, operating experience data, and occurrence reports were used to identify failure modes and to estimate quantitative failure rates for several general types of radiation protection instruments. Likewise, data on instrument repair has been found when possible and used to estimate the mean time to repair. These data can be useful for facility safety assessment, personnel safety assessment, environment assessment, and for equipment and labor planning purposes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Joint Development of SAS4A Code in Application to Oxide-fueled LFR Severe Accident Analysis

The scope of this project was to pursue specific SAS4A liquid-metal cooled reactor (LMR) safety analysis software extensions to simulate postulated accidents with fuel failures for oxide-fueled Lead-cooled Fast Reactors (LFRs). Since most U.S. LMR experience is on sodium-cooled fast reactor options based on past testing and operation experience with EBR-II and FFTF, the DOE’s legacy fast reactor safety analysis capabilities were focused on metal-fueled pool-type concepts with sodium coolant. In recent years, Westinghouse Electric Company (WEC) has decided to pursue an LFR design as one of their next generation nuclear technology options because of its favorable safety and economics attributes. Oxide fuel is considered among other fuel options due to previous WEC experience with this fuel form. Development of this new technology requires the availability of adequately accurate computational tools, some of which can be adapted from versions of similar software used for analysis of other LMRs. Although Argonne National Laboratory’s (ANL) SAS4A/SASSYS-1 safety analysis software suite (shortened as SAS4A code hereafter for brevity) has the basic capabilities to model LFR system designs, the SAS4A code modules used in the analysis of accidents with fuel/cladding failures lack appropriate models for the unique phenomena that govern as-irradiated oxide-fuel damage mechanisms in lead coolant. Therefore, the objective of this project was to extend the capabilities of SAS4A with mechanistic oxide-fuel failure models in lead coolant for margin to failure assessments, analysis of failure modes, location and timing of failures under different accident scenarios consistent with the whole-plant dynamic response including the reactivity feedback, and assessment of the potential for fuel damage propagation due to potential fission gas jet and fuel-fragment/molten fuel impingement to neighboring fuel pins in an assembly. This report provides mainly a summary of Argonne’s technical contributions in the joint project, but the reports and publications by the Participant team are included as references at the end of the report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Impacts of PV Module Connector Failures on Cost and Performance of Utility Scale Photovoltaic Systems

The reliability, cost and performance of electrical connectors are a concern in all types of electrical systems, and demands on connectors used on photovoltaic (PV) systems include that connectors maintain electrical conductivity and physical strength, endure ultraviolet sunlight and high ambient temperature, and resist moisture and chemical intrusion over a very long (>25 year) performance period. Connector failures increase operation and maintenance (O&M) costs and reduce plant production, but connector failure can also cause safety and liability problems, which are of greater concern. This work results from a three-year collaboration between Sandia National Laboratories (SNL), the Electric Power Research Institute (EPRI), and the National Renewable Energy Laboratory (NREL) and funded by the U.S. Department of Energy (DOE) Solar Energy Technology Office (SETO) under Agreements #39035 and #38531 "Connector Reliability Across the US Solar Sector." a multi-pronged investigation of PV connector health across the US (see https://energy.sandia.gov/pvconnectors/). This report presents derivation of a Techno-Economic Analysis (TEA) that models failure modes and frequencies (how often failure occurs), estimates O&M costs and lost production associated with connector failures, and then calculates the effect that PV module connectors can have on Levelized Cost of Energy (LCOE). The model is informed with initial data from quantitative assessment of failure rates, root causes and mechanisms, in-situ diagnostics and data collection, lab-based forensics, and interviews with PV connector manufacturers and plant operators. SNL conducted site inspections at multiple utility-scale sites in different climates and subjected field samples of new, used, and degraded connectors to visual and electrical characterization. EPRI conducted metallurgical analysis of the pin and sleeve conductors to study failure-induced morphological and compositional changes. There is in general a shortage of statistically valid data, but data from PVROM database maintained by SNL was sufficient to ascertain failure rates and lost production as well as provide qualitative insight in its curated maintenance records. This report details the structure of the mathematical model but the sources of data to inform the model will continue to evolve. Analysis of a 100 MW PV plant is provided as an example of the use of the model, with results indicating that connectors are responsible for Annualized O&M Costs of $\$$71,933/year; Annualized Unit O&M Costs of $\$$0.72/kW/year; that a Reserve Account of $\$$187,220 should be available to fund repairs related to connectors; that connectors add $\$$1,494,004 to the Net Present Value of the O&M Costs (project life); and that O&M related to connectors adds about $\$$0.00088/kWh to the Levelized Cost of Energy. The impact of this model is to provide a tool to make the US solar sector more robust by quantifying and monetizing the reliability risks to utility-scale PV systems posed by poorly installed, mismatched and/or poorly designed and manufactured connectors. The TEA provides a model incorporating failure statistics, O&M cost data, and lost production into a single figure of merit, informing decisions and enabling practitioners to optimize cost and performance trade-offs. Stakeholders include connector manufacturers, system designers and equipment specifiers, standards bodies, installers and O&M providers, investors and insurance underwriters. This report supports continued growth of PV predicated on assurances that properly installed and maintained PV system connectors are safe and reliable. The project team is proposing future work including accelerated testing of connectors and expanding the approach taken here to other PV system components, such as TEA for rapid shut-down devices.

14 SOLAR ENERGY↗

Viking Lander reliability program

The Viking Lander reliability program is reviewed with attention given to the development of the reliability program requirements, reliability program management, documents evaluation, failure modes evaluation, production variation control, failure reporting and correction, and the parts program. Lander hardware failures which have occurred during the mission are listed.

Pilny, M. J.↗

Flexible materials technology

A survey of all presently defined or proposed large space systems indicated an ever increasing demand for flexible components and materials, primarily as a result of the widening disparity between the stowage space of launch vehicles and the size of advanced systems. Typical flexible components and material requirements were identified on the basis of recurrence and/or functional commonality. This was followed by the evaluation of candidate materials and the search for material capabilities which promise to satisfy the postulated requirements. Particular attention was placed on thin films, and on the requirements of deployable antennas. The assessment of the performance of specific materials was based primarily on the failure mode, derived from a detailed failure analysis. In view of extensive on going work on thermal and environmental degradation effects, prime emphasis was placed on the assessment of the performance loss by meteoroid damage. Quantitative data were generated for tension members and antenna reflector materials. A methodology was developed for the representation of the overall materials performance as related to systems service life. A number of promising new concepts for flexible materials were identified.

Steurer, W. H.↗

[No Title]

Adequate performance was achieved relatively early in the development of ion engines and most subsequent development programs have focussed on demonstrating adequate engine life. The primary threats to engine reliability over the required service life are damage accumulation failure modes such as accelerator grid failure due to sputter erosion from charge exchange ions, erosion of discharge chamber components by lower energy ion sputtering and grid shorting by flakes of sputter-deposited material. These types of failure may typically be observed only after thousands of hours of operation. The purpose of this paper is to provide a critical review of the approaches used in past ion engine development programs to characterize and control these wearout failure mechanisms.

Ion Engine↗

The System Complexity Metric (SCM) Predicts System Costs and Failure Rates

A complex system has many parts and interactions and so is difficult to understand. Systems with higher complexity generally have higher costs and failure rates. A System Complexity Metric (SCM) is defined to be the sum of the number of nodes, N, in the system block diagram plus the number of one-way interactions, I, between the nodes. SCM = N + I. SCMs are easily determined by direct inspection of high level block diagrams of life support systems. System cost was found to be directly proportional to SCM. The system MTBF (Mean Time Before Failure) is the inverse of the system failure rate. MTBF = 1/f. The system MTBF was found to be proportional to SCM^(-2.2) for estimated preflight MTBFs. As is typical for systems that are not extensively tested and redesigned to eliminate unexpected failure modes, the life support flight failure rates were about ten times higher than the preflight estimates and the MTBFs one-tenth the preflight estimates. The system MTBF was found to be proportional to SCM^(-2.6) for observed flight MTBFs.

System compleity↗

Stress testing on silicon carbide electronic devices for prognostics and health management.

Power conversion systems for energy storage and other distributed energy resource applications are among the drivers of the important role that power electronics plays in providing reliable electricity. Wide band gap semiconductors such as silicon carbide (SiC) and gallium nitride (GaN) will help increase the performance and efficiency of power electronic equipment while condition monitoring (CM) and prognostics and health management (PHM) will increase the operational availability of the equipment and thereby make it more cost effective. Voltage and/or temperature stress testing were performed on a number of SiC devices in order to accelerate failure modes and to identify measureable shifts in electrical characteristics which may provide early indication of those failures. Those shifts can be interpreted and modeled to provide prognostic signatures for use in CM and/or PHM. Such experiments will also lead to a deeper understanding of basic device physics and the degradation mechanisms behind failure.

42 ENGINEERING↗