Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fault characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Hawthorne Nevada Deep Direct-Use Feasibility Study - References, Reports, Literature

The objective of this project is to use a multi-disciplinary, three-tiered approach to assess the geothermal resource and determine the feasibility of implementing a large-scale, direct-use facility for the Hawthorne Army Depot (HAD) and the various town and county facilities in Hawthorne, Nevada. This assessment directly targets a geothermal resource recently characterized by the Navy Geothermal Program Office (GPO) as part of a focused exploration and development campaign. Data includes: Zip folder containing information from Bjornstad. Includes isotope, temperature, water, well, and reports from 2002; Zip folder contains PDF and power point files of references for the Hawthorne Geothermal project; Zip folder containing PDF files of the literature cited in the proposal.

15 GEOTHERMAL ENERGY↗

Fort Nelson Test Site - Site Characterization Report

The Plains CO 2 Reduction (PCOR) Partnership, led by the Energy & Environmental Research Center (EERC), is working with Spectra Energy Transmission (SET) to determine the feasibility of large-scale injection of carbon dioxide (CO 2 ) into a deep brine-saturated carbonate formation near Fort Nelson, British Columbia, Canada, for the purpose of CO 2 storage. Site characterization must be conducted prior to large-scale injection of CO 2 at the Fort Nelson test site. Effective characterization supports modeling; risk assessment; and monitoring, verification, and accounting (MVA) programs that will constantly evolve to suit the project’s needs. Site characterization activities have been conducted to address three critical issues affecting the viability of the Fort Nelson test site: 1) the capacity of the target formation, 2) injectivity, and 3) containment – the potential for leakage of the injected CO 2 into overlying formations and/or the near-surface environment. Geochemical, mineralogical/petrophysical, geomechanical, and hydrogeological data have been collected for the purpose of supporting modeling, risk assessment, and MVA activities. The geology, stratigraphy, and lithology have been evaluated, delineated, and described for the entire sedimentary succession from the base of the Devonian age Presqu’ile reef complex to the top of the Fort Simpson shale (cap rock) in the Fort Nelson project area. The structural elements of the reef complex have been investigated to identify any existing faults and/or fractures that would allow migration of any reservoir and/or injected fluids out of the storage reservoir. On this basis, a geologic model has been built, with particular attention given to the Devonian injection interval and overlying and underlying sealing formations.

54 ENVIRONMENTAL SCIENCES↗

Microstructure, precipitates and hardness of selectively laser melted AlSi10Mg alloy before and after heat treatment

Highlights: • Microstructural characterization of SLM AlSi10Mg alloy and comparison with cast and powder AlSi10Mg • Effect of solution heat treatment and aging on the hardness change of SLM AlSi10Mg alloy • Evolution of strengthening precipitates and Fe-rich intermetallics in SLM AlSi10Mg during heat treatment - Abstract: The microstructure and precipitates within selectively laser melted (SLM) AlSi10Mg alloys in the as-built state and after T6 heat treatment were examined and correlated to the hardness evolution. The as-built alloy exhibited columnar patterns perpendicular to the build-direction and fish-scale pattern along the build-direction originating from the melt pool. The microstructure consisted of fine Al cells and eutectic structure with up to 4 μm in size. Tiny needle-like Si particles with highly faulted structure were identified within the Al cells and formed semi-coherent interface with the matrix. Nanoscale Si particles and π-Al{sub 8}Si{sub 6}Mg{sub 3}Fe phase were observed to segregate along the cell and grain boundary. Solution heat treatment (SHT) at 520 °C resulted in the dissolution of Al cellular microstructure. Precipitation and coarsening of the Si particles occurred, while the aspect ratio of Si particles remained nearly constant. The π-Al{sub 8}Si{sub 6}Mg{sub 3}Fe phase decomposed into plate-shaped β-Al{sub 5}SiFe. The artificial aging (AA) at 160 °C did not alter the microstructure but led to the formation of metastable Mg{sub 2}Si precipitates. The GP zones and β″ were identified through transmission electron microscopy after AA of 6 h, and β″ existed up to AA of 24 h. The hardness decreased after SHT due to the coarsening of the microstructure and reduced solid solution hardening. Hardness reached maximum magnitude after AA of 6–10 h due to the precipitation hardening, and remained relatively unchanged up to AA of 24 h. Microstructure and/or hardness of gas atomized powders and bulk cast AlSi10Mg alloys were also examined as references.

36 MATERIALS SCIENCE↗

Lattice-engineered Si{sub 1-x}Ge{sub x}-buffer on Si(001) for GaP integration

We report a detailed structure and defect characterization study on gallium phosphide (GaP) layers integrated on silicon (Si) (001) via silicon-germanium (SiGe) buffer layers. The presented approach uses an almost fully relaxed SiGe buffer heterostructure of only 400 nm thickness whose in-plane lattice constant is matched to GaP—not at room but at GaP deposition temperature. Single crystalline, pseudomorphic 270 nm thick GaP is successfully grown by metalorganic chemical vapour deposition on a 400 nm Si{sub 0.85}Ge{sub 0.15}/Si(001) heterosystem, but carries a 0.08% tensile strain after cooling down to room temperature due to the bigger thermal expansion coefficient of GaP with respect to Si. Transmission electron microscopy (TEM) studies confirm the absence of misfit dislocations in the pseudomorphic GaP film but growth defects (e.g., stacking faults, microtwins, etc.) especially at the GaP/SiGe interface region are detected. We interpret these growth defects as a residue of the initial 3D island coalescence phase of the GaP film on the SiGe buffer. TEM-energy-dispersive x-ray spectroscopy studies reveal that these defects are often correlated with stoichiometric inhomogeneities in the GaP film. Time-of-flight Secondary ion mass spectrometry detects sharp heterointerfaces between GaP and SiGe films with a minor level of Ga diffusion into the SiGe buffer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Validating Protection System Behavior with Machine Learning in a Master State Overseer

As power system protection devices continue the widespread transition from analog to digital, they become increasingly intricate. The internal functions and communication between critical grid components must now be significantly more complex to keep up with the demands of the modern smart grid. This brings increased difficulty in maintenance and monitoring, making it harder to identify potential misoperation, power anomalies, and cyber threats. Such issues are often only pinpointed after an exhaustive and costly post-mortem analysis, when a major outage or damage has already occurred. A solution is needed for validating protection systems as they operate, independently evaluating grid state and confirming whether the protection system is behaving accordingly. As opposed to incident response, this acts as a constant verification mechanism that raises a flag when subtler issues are noticed, catching them earlier and preventing larger incidents. This work presents the implementation of such a system, expanding on the prototype developed by the authors in a previous paper. This is accomplished with a machine learning (ML) system capable of validating the performance of protection systems by classifying anomalous events and characterizing protection system responses based solely on available current and voltage measurements. Additionally, this system is contextualized within a larger, modular Master State awareness Overseer (MSO) framework, responsible for monitoring, analyzing, and managing an electric grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Numerical and Analytical Modeling of Flow Partitioning in Partially Saturated Fracture Networks

Infiltration processes in fractured-porous media remain a crucial, yet not very well understood component of recharge and vulnerability assessment. Under partially-saturated conditions flows in fractures, percolating fracture networks, and fault zones contribute to the fastest spectrum of infiltration velocities via preferential pathways. Specifically, the partitioning dynamics at fracture intersections determine the magnitude of flow fragmentation into vertical and horizontal components and hence the bulk flow velocity and dispersion of fracture networks. In this work, we derive an approximate analytical solution for the partitioning process and validate it using smoothed particle hydrodynamics simulations. The developed transfer function is conceptually based on simulation results and laboratory experiments carried out in previous works. It allows to efficiently simulate flow through fracture networks with simple cubic structure and arbitrary number of fractures and aperture sizes via linear response theory and convolution of a given input signal. We derive a non-dimensional bulk flow velocity ($\widetilde{v}$) and dispersion coefficient ($\widetilde{D}$) to characterize fracture networks in terms of dimensionless horizontal and vertical time scales $\tau_m$ and $\tau_0$. The dispersion coefficient is shown to strongly depend on the horizontal time scale and converges towards a constant value of $0.08$ within reasonable fluid and geometrical parameter ranges, while the non-dimensional velocity exhibits a characteristic $\widetilde{v} \sim \tau_m^{-1/2}$ scaling. Given that hydraulic information is often only available at limited places within (fractured-porous) aquifer system, such as boreholes or springs, our study intends to provide a rudimentary analytical concept to potentially reconstruct internal fracture network geometries from external boundary information, e.g., the dispersive properties of discharge (groundwater level fluctuations).

42 ENGINEERING↗

Structure and Voltage Recovery Driven by Defects Elimination in Li-Rich Layered Oxide Cathode Materials

Lithium-ion batteries (LIBs) are ubiquitous in a wide range of technologies, including cell phones, electric vehicles, and energy grid, and are indispensable in the transition toward sustainable energy technology. The battery performance is inherently connected to the capability of lithium ions to reversibly intercalate with the electrodes. The capacity of classical layered transition metal (TM) oxides, the primary commercial cathode materials, is limited to cationic redox activity. Anionic redox has thus emerged as a new paradigm for designing novel cathodes for next generation LIBs. It is recently confirmed oxygen redox in lithium-rich layered oxides (LRLO) with composition xLi 2 MnO 3 ∙(1-x)LiTMO 2 , which enables this group of materials exhibit reversible capacities exceeding 280 mAh g -1 . Unfortunately, this material undergoes voltage fading and instability that is rooted in irreversible structural transformation in terms of defects formation including lithium and oxygen vacancies, lithium tetrahedron, TM migration, edge dislocations, stacking fault, and local strain. Modification methods including morphology control, composition gradient, surface treatment, foreign elements doping, etc., have been proposed in the literatures to mitigate the defects formation and maintain the structure reversibility. Despite their improvement, the intrinsic voltage fading is still inevitable and remains a challenge that will require considerable effort to overcome. In this work, we demonstrate a path to recover the layer structure and working voltage through high-temperature annealing. The treatment at high temperature recovers the local Li-excess environments around oxygen, oxygen stacking sequence, and eliminates microstrain associated with different defects. As a result, the voltage profile once more shows plateau region during charge and the average discharge voltage is restored of the cycled cathode after heat treatment. Both theoretical calculations and experimental characterizations illustrate the mechanisms underlying the heating induced recovery. The structure metastability and defects removal are decisive in structure and voltage recovery of LRLO cathode material.

Zhang, Minghao↗

Vapor Compression Distillation Subsystem (VCDS) component enhancement, testing and expert fault diagnostics development, volume 1

Vapor compression distillation technology for phase change recovery of potable water from wastewater has evolved as a technically mature approach for use aboard the Space Station. A program to parametrically test an advanced preprototype Vapor Compression Distillation Subsystem (VCDS) was completed during 1985 and 1986. In parallel with parametric testing, a hardware improvement program was initiated to test the feasibility of incorporating several key improvements into the advanced preprototype VCDS following initial parametric tests. Specific areas of improvement included long-life, self-lubricated bearings, a lightweight, highly-efficient compressor, and a long-life magnetic drive. With the exception of the self-lubricated bearings, these improvements are incorporated. The advanced preprototype VCDS was designed to reclaim 95 percent of the available wastewater at a nominal water recovery rate of 1.36 kg/h achieved at a solids concentration of 2.3 percent and 308 K condenser temperature. While this performance was maintained for the initial testing, a 300 percent improvement in water production rate with a corresponding lower specific energy was achieved following incorporation of the improvements. Testing involved the characterization of key VCDS performance factors as a function of recycle loop solids concentration, distillation unit temperature and fluids pump speed. The objective of this effort was to expand the VCDS data base to enable defining optimum performance characteristics for flight hardware development.

Kovach, L. S.↗

Tools Ensure Reliability of Critical Software

In November 2006, after attempting to make a routine maneuver, NASA's Mars Global Surveyor (MGS) reported unexpected errors. The onboard software switched to backup resources, and a 2-day lapse in communication took place between the spacecraft and Earth. When a signal was finally received, it indicated that MGS had entered safe mode, a state of restricted activity in which the computer awaits instructions from Earth. After more than 9 years of successful operation gathering data and snapping pictures of Mars to characterize the planet's land and weather communication between MGS and Earth suddenly stopped. Months later, a report from NASA's internal review board found the spacecraft's battery failed due to an unfortunate sequence of events. Updates to the spacecraft's software, which had taken place months earlier, were written to the wrong memory address in the spacecraft's computer. In short, the mission ended because of a software defect. Over the last decade, spacecraft have become increasingly reliant on software to carry out mission operations. In fact, the next mission to Mars, the Mars Science Laboratory, will rely on more software than all earlier missions to Mars combined. According to Gerard Holzmann, manager at the Laboratory for Reliable Software (LaRS) at NASA's Jet Propulsion Laboratory (JPL), even the fault protection systems on a spacecraft are mostly software-based. For reasons like these, well-functioning software is critical for NASA. In the same year as the failure of MGS, Holzmann presented a new approach to critical software development to help reduce risk and provide consistency. He proposed The Power of 10: Rules for Developing Safety-Critical Code, which is a small set of rules that can easily be remembered, clearly relate to risk, and allow compliance to be verified. The reaction at JPL was positive, and developers in the private sector embraced Holzmann's ideas.

Source record↗

Disorderly Conduct of Benzamide IV: Crystallographic and Computational Analysis of High Entropy Polymorphs of Small Molecules

Benzamide, a simple derivative of benzoic acid and a common intermediate of pharmaceutical compounds, was reported to form two polymorphs in 1832, but the single crystal structure of the more stable form was not solved until 1959. Nearly 50 years later, the second form was characterized by powder diffraction, followed shortly thereafter by characterization of a third form, a polytype of the most thermodynamically stable Form I. These two new forms, Forms II and III, are metastable. Herein, we describe a fourth polymorph, Form IV, discovered by melt crystallization concurrently with its crystallization under confinement at small length scales (<10 nm), where it is stable indefinitely. Form III exists under confinement in larger pores, and melting point data for different pore sizes corroborate the existence of Form IV below 10 nm. Form IV is highly disordered, precluding indexing of powder diffraction data other than hk0 reflections. Nonetheless, a combination of powder X-ray diffraction and computational crystal structure prediction reveals that Form IV contains a 2D motif resembling that of Form II, but with longrange order in the third dimension masked by ubiquitous stacking faults. This approach relies on distilling a large number of candidate structures to a few possible disorder models based on benzamide tetrads that organize in 2D parquet-like tiles, with organization along the third dimension, that can be modeled with various stacking fault configurations having distinct intermolecular interactions and translations in the dimension orthogonal to the tiling planes. These observations reveal a bewildering crystallographic complexity for such a simple molecule. Nonetheless, the approach described herein demonstrates that challenging structures that may be abandoned prematurely because of poor crystallinity, twinning, or disorder can be solved.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design Support of an Above Cap-rock Early Detection Monitoring System using Simulated Leakage Scenarios at the FutureGen2.0 Site

The FutureGen 2.0 Project will design and build a first-of-its-kind, near-zero emissions coal-fueled power plant with carbon capture and storage (CCS). To assess storage site performance and meet the regulatory requirements of the Class VI Underground Injection Control (UIC) Program for CO 2 Geologic Sequestration, the FutureGen 2.0 project will implement a suite of monitoring technologies designed to evaluate CO 2 mass balance and detect any unforeseen loss in CO 2 containment. The monitoring program will include direct monitoring of the reservoir, and early-leak-detection monitoring directly above the primary confining zone. This preliminary modeling study described here focuses on hypothetical leakage scenarios into the first permeable unit above the primary confining zone (Ironton Sandstone) and is used to support assessment of early-leak detection capabilities. Future updates of the model will be used to assess potential impacts on the lowermost underground source of drinking water (Saint Peter Sandstone) for a range of theoretical leakage scenarios. This preliminary modeling evaluation considers both pressure response and geochemical signals in the overlying Ironton Sandstone. This model is independent of the FutureGen 2.0 reservoir model in that it does not simulate caprock discontinuities, faults, or failure scenarios. Instead this modeling effort is based on theoretical, volumetric-rate based leakage scenarios. The scenarios include leakage of 1% of the total injected CO 2 mass, but spread out over different time periods (20, 100, and 500 years) with each case yielding a different mass flux (i.e., smaller mass fluxes for longer duration leakage cases]. A brine leakage scenario using a volumetric leakage similar to the 20 year 1% CO 2 case was also considered. A framework for the comparison of the various cases was developed based on the exceedance of selected pressure and geochemical thresholds at different distances from the point of leakage and at different vertical positions within the Ironton Sandstone. These preliminary results, and results from an updated models that incorporate additional site-specific characterization data, support development/refinement of the monitoring system design.

54 ENVIRONMENTAL SCIENCES↗

Characterizing crystalline defects in single nanoparticles from angular correlations of single-shot diffracted X-rays

Characterizing and controlling the uniformity of nanoparticles is crucial for their application in science and technology because crystalline defects in the nanoparticles strongly affect their unique properties. Recently, ultra-short and ultra-bright X-ray pulses provided by X-ray free-electron lasers (XFELs) opened up the possibility of structure determination of nanometre-scale matter with Å spatial resolution. However, it is often difficult to reconstruct the 3D structural information from single-shot X-ray diffraction patterns owing to the random orientation of the particles. This report proposes an analysis approach for characterizing defects in nanoparticles using wide-angle X-ray scattering (WAXS) data from free-flying single nanoparticles. The analysis method is based on the concept of correlated X-ray scattering, in which correlations of scattered X-ray are used to recover detailed structural information. WAXS experiments of xenon nanoparticles, or clusters, were conducted at an XFEL facility in Japan by using the SPring-8 Ångstrom compact free-electron laser (SACLA). Bragg spots in the recorded single-shot X-ray diffraction patterns showed clear angular correlations, which offered significant structural information on the nanoparticles. The experimental angular correlations were reproduced by numerical simulation in which kinematical theory of diffraction was combined with geometric calculations. We also explain the diffuse scattering intensity as being due to the stacking faults in the xenon clusters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pattern formation during healing of fluid-filled cracks: an analog experiment

The formation and subsequent healing of cracks and crack networks may control such diverse phenomena as the strengthening of fault zones between earthquakes, fluid migrations in the Earth's crust, or the transport of radioactive materials in nuclear waste disposal. An intriguing pattern-forming process can develop during healing of fluid-filled cracks, where pockets of fluid remain permanently trapped in the solid as the crack tip is displaced driven by surface energy. Here, we present the results of analog experiments in which a liquid was injected into a colloidal inorganic gel to obtain penny-shaped cracks that were subsequently allowed to close and heal under the driving effect of interfacial tension. Depending on the properties of the gel and the injected liquid, two modes of healing were obtained. In the first mode, the crack healed completely through a continuous process. The second mode of healing was discontinuous and was characterized by a 'zipper-like' closure of a front that moved along the crack perimeter, trapping fluid that may eventually form inclusions trapped in the solid. This instability occurred only when the velocity of the crack tip decreased to zero. Our experiments provide a cheap and simple analog to reveal how aligned arrays of fluid inclusions may be captured along preexisting fracture planes and how small amounts of fluids can be permanently trapped in solids, modifying irreversibly their material properties.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The effects of high temperature processing on the structural and optical properties of oxygenated CdS window layers in CdTe solar cells

High efficiency CdTe solar cells typically use oxygenated CdS (CdS:O) window layers. We synthesize CdS:O window layers at room temperature (RT) and 270 °C using reactive sputtering. The band gaps of CdS:O layers deposited at RT increase when O{sub 2}/(O{sub 2} + Ar) ratios in the deposition chamber increase. On the other hand, the band gaps of CdS:O layers deposited at 270 °C decrease as the O{sub 2}/(O{sub 2} + Ar) ratios increase. Interestingly, however, our high temperature closed-space sublimation (CSS) processed CdTe solar cells using CdS:O window layers deposited at RT and 270 °C exhibit very similar cell performance, including similar short-circuit current densities. To understand the underlying reasons, CdS:O thin films deposited at RT and 270 °C are annealed at temperatures that simulate the CSS process of CdTe deposition. X-ray diffraction, atomic force microscopy, and UV-visible light absorption spectroscopy characterization of the annealed films reveals that the CdS:O films deposited at RT undergo grain regrowth and/or crystallization and exhibit reduced band gaps after the annealing. Our results suggest that CdS:O thin films deposited at RT and 270 °C should exhibit similar optical properties after the deposition of CdTe layers, explaining the similar cell performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Relating the long-term and short-term vertical deformation across a transect of the forearc in the central Mexican subduction zone

Earthquake-cycle deformation, which includes earthquake ruptures, interseismic strain, and transient slow slip events, spans spatial scales ranging from fractions of a meter to thousands of kilometers. Similarly, temporal scales range from seconds during an earthquake rupture to thousands of years of strain accumulation between earthquakes. We discuss results regarding the vertical crustal deformation associated with both slow and rapid crustal deformation across a transect of the central Mexican subduction forearc in the Guerrero seismic gap, where the Cocos plate underthrusts the North America plate. This sector of the subduction zone is characterized by a flat-slab geometry with zones of sharp bending-unbending of the slab, irregularly distributed seismicity, and exceptionally large slow slip events. We used the river network, topography, geomorphic features, and morphometry on a transect across the forearc to assess Quaternary crustal deformation. The Papagayo drainage network shows that the forearc has been uplifted since the late Cenozoic (~25 Ma), and that rates of uplift increased since the beginning of the Holocene. Uplift is not homogeneous but shows a trend of increase away from the coast. This vertical deformation is strongly influenced by subduction processes. Thus, the Papagayo River network is strongly controlled by Holocene earthquake cycle processes. This is particularly true for the southern section of the drainage basin, where E-W-striking left-lateral strike-slip faults with a vertical component offset the course of the main river. These faults are accommodating part of the oblique plate convergence at the Mexican subduction zone. We measured the height of a series of terraces and dated quartz extracts by optically stimulated luminescence, and we calculated long-term rates of uplift ranging from 0.5 to 4.9 mm/yr. We discuss associations of forearc topography, faults, and long-term crustal deformation with the Cocos slab geometry, distribution of slow slip events, and earthquake-cycle deformation.

58 GEOSCIENCES↗

Sensor enabled data-driven predictive analytics for modeling and control with high penetration of DERs in distribution systems

The electric power grid is undergoing a tremendous transformation due to the increasing penetration of renewable energy resources beginning with wind and more recently with the distributed energy resources (DERs) such as solar and battery storage. DERs have dramatically changed the role of the distribution systems in the overall power grid, and they are expected to contribute a significant portion of power generation in the future. If current trends for DERs continue, system operation and control will need to change dramatically for improved grid reliability and resiliency. As renewable resources increase in penetration, new and challenging operational, planning, and design problems are expected to emerge. Some of the key challenges that arise in the planning and operation of the future grid are: 1) Quantifying the impact of high DER penetration in distribution systems on bulk grid behavior over multiple time scales. 2) Identifying whether a particular DER configuration/settings have a large impact on the overall grid behavior. These challenges can be addressed in an offline manner using detailed T&D grid models and they can also be addressed in an online manner using sensor measurements. In particular, the advancement and planned growth in sensor technology in power grid over various voltage levels provide us with a unique opportunity to tackle these challenges from a data analytic perspective without needing detailed T&D grid models. A few questions that naturally arise when addressing the challenges from DERs using sensor data are: 1) How can we use limited sensor measurements to monitor & control voltage stability and small signal stability of the bulk system? 2) How can we ensure that the developed data analytic methods are robust to data availability and quality issues? 3) How can we compute the developed analytics in a scalable manner using streaming measurements? In this project, we addressed the aforementioned challenges arising from DERs and answered the questions raised above on how to effectively use the sensor measurements to enhance the reliability and performance of the electric grid. Thus, the overarching goal of this project is to develop effective reduced/representative system models from data that make the computational complexity sufficiently manageable so as to be useful to simulate, analyze, and even control complex non-linear power systems dynamics with large penetrations of DERs. In order to achieve the objective, the project team established a four-fold technical approach 1) Formulated a combined transmission-distribution co-simulation framework for data generation and validation, 2) Derived reduced/representative models of power systems based on data-driven methods for efficient computation and appropriate representation of system behavior, 3) Developed data driven characterization of power system behavior based on transfer operator theory, machine learning and optimization for model estimation, 4) Incorporated a scalable data management and processing architecture using distributed Kafka streaming applications that coordinate input data streams to the developed data analytics. The key accomplishments of the project are: 1) Development of a scalable multi-timescale T&D co-simulation framework (both for steady state and for dynamic co-simulation) using commercial solvers (PSSE and GridLAB-D). The steady-state T&D co-simulation interface is shared with our industry partner (PJM). 2) A structured reduced order dynamic model of distribution systems that can represent partial motor stalling along with a systematic procedure to derive the model parameters. 3) A PMU based online method to monitor, localize and mitigate fault-induced delayed voltage recovery using DER reactive support and load control in distribution systems. 4) Development of linear operator based robust methodologies for dynamic state estimation, uncertainty quantification, system identification and trajectory prediction for power system dynamics. 5) An adaptive damping control for utilizing wind energy resources to provide oscillation damping and system stability. 6) Implementation of Kafka-based framework for efficient processing of streaming data using Linux-based local virtual environment.

DER integration↗

Transient behavior of a scaled RCCS test facility under postulated fault and accident scenarios

Tests were performed on the Natural convection Shutdown heat removal Test Facility (NSTF) to simulate design basis accident and postulated fault scenarios. Residing at Argonne National Laboratory, the NSTF stands nearly 26-m in total height and reflects a ½ scale reactor cavity cooling system (RCCS) for high temperature gas cooled reactors. The following manuscript details three test conditions performed on the experimental test facility. The first simulated the reactor pressure vessel (RPV) boundary condition during depressurized conduction cool down accident with small primary leak, and was repeated during both winter and summer seasons. The second examined a short-circuit break between the inlet and outlet flow paths, and was performed in three incremental stages of nominal flow area break size. The third and final test case studied system behavior with varying amounts of cooling channel blockages, up to and including 50% flow areas. Nominal component temperatures, heat removal performance, and system stability will be presented to characterize the behavior at these conditions.

decay heat removal↗

The tectonic and volcanic evolution of Venus: Catastrophic or gradual?

Radar imaging and altimetry data from the Magellan mission have yielded important new constraints on the tectonic and volcanic history of Venus and on its internal dynamics. The planet lacks global plate tectonics, but a number of chasm systems and corona moat structures have arcuate planforms, asymmetric topogrpahic profiles, and relief analogous to deep-sea trenches on Earth and may be products of limited lithospheric underthrusting or subduction. Several lines of evidence point to a crust and upper mantle stronger than would be predicted by simple extrapolation from Earth and the 450 K greater surface temperature; these include the unrelaxed depths of impact craters, apparently large values of elastic lithosphere thickness, and large ratios of gravity to topography. The density of impact craters indicates an averate crater retention age of about 500 My, but not more than 5% of the recognized craters have been volcanically embayed. This last observation has led to the proposal that Venus has been subjected to one or more global resurfacing events, the latest about 500 My ago, and that the volcanic flux during intervals between such events has been low. That more recent tectonic activity has been widespread, however, is indicated by the high relief and slopes of mountains, chasm walls, and plateau margins; the significant fraction (0.3) of impact craters deformed by younger faults; and the postformational vertical deformation of long channels. Interior dynamical scenarios advanced to account for episodic volcanic resurfacing include catastrophic overturn of a global lithosphere thickened by cooling or compositional buoyancy and strongly time-dependent mantle convective heat flux. Outgassing considerations and analogy with Earth and other terrestrial planets, however, suggests that such catastrophic models are unlikely. If the mantle of Venus cooled more efficiently than that of Earth because of, say, different boundary conditions, a different flow law, or a different degree of layering, then the planet may in the last 500 My have attained lesser mantle temperatures, lower mantle heat flux, and a significantly lesser rate of magma production than Earth yet still display evidence for ongoing convection and active tectonics. Such a 'cold Venus' scenario would be broadly consistent with observations yet be characterized by a gradual volcanic and tectonic evolution.

Solomon, Sean C.↗