Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Connection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Error induced by coordinate systems

It is pointed out that the choice of a curvilinear coordinate system can have a substantial effect on the error in the numerical solution of a partial differential equation. The truncation error is dependent not only on the higher order derivatives of the solution and the local grid spacing, but also on the rate-of-change of the grid spacing and on the departure of the grid from orthogonality. In connection with the present investigation, an analysis is conducted of the local truncation error in the approximation of first and second order derivatives on a curvilinear grid. Attention is given to a number of examples which illustrate the two fundamental sources of truncation error in the numerical solution of partial differential equations on curvilinear coordinate systems. The first is the grid spacing and changes in grid spacing which is measured by the first and second order derivatives of the functions defining the coordinate system. The second source is the higher order derivatives of the solution itself.

Mastin, C. W.↗

Behavior of Multiple PV Plants in Future Power Grids During Events

As the integration of multiple photovoltaic (PV) plants into power grids grows, the dynamic response of each plant and their interactions during transient events demands a deeper understanding. In this paper, the dynamic behavior of multiple PV plants connected to future power grids is comprehensively explored using site-specific high-fidelity electromagnetic transient (EMT) PV plant models and generic high-fidelity EMT PV plant models. This research demonstrates the need to employ multiple high-fidelity EMT PV plant models to understand the intricate interactions between multiple PV plants during grid events. These models, developed in Fortran within the PSCAD environment, encompass a range of operational scenarios and plant configurations, offering invaluable insights crucial for future system planning with multiple PV plants to enhance grid stability.

Marthi, Phani Ratna Vanamali [ORNL] (ORCID:0000000↗

Parallel transport sweeps on two-dimensional cartesian and hexagonal grids

This paper aims to provide a proof of concept for parallel transport sweeps on two-dimensional hexagonal grids for the discrete ordinates transport equation. While the method is an extension of the popular and well-established Koch-Baker-Alcoulffe (KBA) algorithm, there are significant differences between the cartesian and hexagonal grid and thereafter sweep. The most important is the three-way connectivity of hexagons within the grid which creates greater dependencies between the elements. The KBA method in structured orthogonal grids was first implemented in the DRAGON5 code and the method is first described here. The differences in implementation for the hexagonal grid are also described. Benchmark results are also presented, showing roughly 10 times speedup in computational times with roughly 100 processors, in both cases. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Streamline integration as a method for two-dimensional elliptic grid generation

We propose a new numerical algorithm to construct a structured numerical elliptic grid of a doubly connected domain. Our method is applicable to domains with boundaries defined by two contour lines of a two-dimensional function. Furthermore, we can adapt any analytically given boundary aligned structured grid, which specifically includes polar and Cartesian grids. The resulting coordinate lines are orthogonal to the boundary. Grid points as well as the elements of the Jacobian matrix can be computed efficiently and up to machine precision. In the simplest case we construct conformal grids, yet with the help of weight functions and monitor metrics we can control the distribution of cells across the domain. Our algorithm is parallelizable and easy to implement with elementary numerical methods. We assess the quality of grids by considering both the distribution of cell sizes and the accuracy of the solution to elliptic problems. Among the tested grids these key properties are best fulfilled by the grid constructed with the monitor metric approach. - Graphical abstract: - Highlights: • Construct structured, elliptic numerical grids with elementary numerical methods. • Align coordinate lines with or make them orthogonal to the domain boundary. • Compute grid points and metric elements up to machine precision. • Control cell distribution by adaption functions or monitor metrics.

97 MATHEMATICS AND COMPUTING↗

Control and Grid Support Function Evaluation for a Three-Phase Back-to-Back Modular Multilevel Converter System

This paper focuses on the evaluation of advanced inverter controls for a 500kW back-to-back (B2B), silicon carbide, multilevel modular converter (MMC) used as a direct-connected medium-voltage grid intertie. A decentralized hierarchical controller architecture for the MMC system is presented, which uses the main controller to implement higher level grid interconnection functions per the IEEE 1547–2018 standards and the local controllers to execute lower level closed-loop functionality of the MMC stages. This paper presents and elaborates on the grid functionalities are elaborated and presented. The back-to-back converter system is equipped with local controllers and their corresponding functionalities are presented. Case study results for the corresponding functionalities presented show the effectiveness of the proposed architecture. To enhance the operation capabilities of the system, a parameter update scheme has been implemented and utilized in unison with the controller.

decentralized control↗

Towards Optimal and Executable Distribution Grid Restoration Planning With a Fine-Grained Power-Communication Interdependency Model

Distribution service restoration (DSR) under natural disasters is always a critical and challenging problem for utility companies. An effective solution must not ignore the power-communication interdependency as various systems are getting increasingly connected in the Smart Grid era. In this paper, we propose a two-layer distribution system model with both power and communication components. Based on this model, we formulate the restoration process as a routing problem that schedules the path and action sequence of utility crews that involves repairing damaged components, closing power switches, and enabling communication paths between the control center and remote field devices. Further, we develop a simulation-based method to quantitatively evaluate the restoration process with public reference models of large-scale power systems. The experimental results show that our method improves the total restored energy up to 57.6% and reduces the recovery time up to 63% by considering the power-communication interdependency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Generation of a composite grid for turbine flows and consideration of a numerical scheme

A composite grid was generated for flows in turbines. It consisted of the C-grid (or O-grid) in the immediate vicinity of the blade and the H-grid in the middle of the blade passage between the C-grids and in the upstream region. This new composite grid provides better smoothness, resolution, and orthogonality than any single grid for a typical turbine blade with a large camber and rounded leading and trailing edges. The C-H (or O-H) composite grid has an unusual grid point that is connected to more than four neighboring nodes in two dimensions (more than six neighboring nodes in three dimensions). A finite-volume lower-upper (LU) implicit scheme to be used on this grid poses no problem and requires no special treatment because each interior cell of this composite grid has only four neighboring cells in two dimensions (six cells in three dimensions). The LU implicit scheme was demonstrated to be efficient and robust for external flows in a broad flow regime and can be easily applied to internal flows and extended from two to three dimensions.

Choo, Y.↗

Security and Trust Metrics for Edge Computing

The present state of edge computing is an environment of different computing capabilities connected via a wide variety of communication paths. The energy grid is relying upon distributed energy devices connected at the edge of the internet. Consider the scenario where each edge device is customer-owned distributed energy resource (DER) that is connected via a trustworthy link to a grid service provider. Each DER keeps a local simple trust record of interactions. Information protection is provided by internet https standards, however, trust must be evaluated throughout operation. This paper presents a model for representing and evaluating trust in general and applied to the energy grid as a key example. Actors on the edge may interact with each other as well as with a central datacenter.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A gating grid driver for time projection chambers

A simple but novel driver system has been developed to operate the wire gating grid of a Time Projection Chamber (TPC). This system connects the wires of the gating grid to its driver via low impedance transmission lines. When the gating grid is open, all wires have the same voltage allowing drift electrons, produced by the ionization of the detector gas molecules, to pass through to the anode wires. When the grid is closed, the wires have alternating higher and lower voltages causing the drift electrons to terminate at the more positive wires. Rapid opening of the gating grid with low pickup noise is achieved by quickly shorting the positive and negative wires to attain the average bias potential with N-type and P-type MOSFET switches. The circuit analysis and simulation software SPICE shows that the driver restores the gating grid voltage to 90% of the opening voltage in less than 0.20 µs, for small values of the termination resistors. When tested in the experimental environment of a time projection chamber larger termination resistors were chosen so that the driver opens the gating grid in 0.35 µs. In each case, opening time is basically characterized by the RC constant given by the resistance of the switches and terminating resistors and the capacitance of the gating grid and its transmission line. By adding a second pair of N-type and P-type MOSFET switches, the gating grid is closed by restoring 99% of the original charges to the wires within 3 µs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Opening the Door to Grid-Interactive Efficient Buildings with Energy Codes

Building codes represent standard design practice in the construction industry and must continually evolve to account for advancing technologies and innovative practices. Energy codes have historically focused on energy efficiency within buildings and across their systems. However, many of tomorrow's technologies go beyond efficiency and target increased flexibility. These demand flexibility (DF) measures can postpone or reduce building electric load based on price or other grid signals, and include smart appliances, connected lighting, and connected mechanical systems. Expanding codes to enable such grid-interactive efficient building (GEB) has the potential to influence their realization at scale, which will support renewable-energy grid-integration and building-sector decarbonization. However, considering DF measures in code development creates a new set of challenges for codes and the practices contained therein. This paper considers the role of building energy codes in enabling GEB. Specifically, it reviews the status of demand flexibility (DF) measures in current commercial building energy code. It examines the national model code development process and identifies components barring the consideration and inclusion of DF measures - including code scope, characterization and analysis of proposed new prescriptive measures, and accounting for time-of-day and geographic differences in their benefits. The paper presents findings from code development analyses that indicate the cost benefit of DF measures and the limitations associated with current code development conventions. To encourage building flexibility and improved energy resilience moving forward, recommendations are made for removing code development barriers and sanctioning DF measure consideration in future model codes.

Building Energy Codes and Standards, Grid-Interact↗

A method to identify weak points of interconnection of renewable energy resources

The increasing penetration of renewable energy resources (RERs) is challenging power grid planning and operation in maintaining grid reliability. Potential power grid reliability and stability issues may arise when large-scale RERs are connected to a weak power grid. These issues may become more significant due to the mutual interactions among RERs that are interconnected electrically close through a power network. Weakness analysis based on grid strength assessment is useful for identifying the potential weak grid issues. However, when taking into account the impact of the interactions among RERs, the weakness analysis becomes computationally challenging. Different combinations of points of interconnections (POIs) of RERs may have different impacts on grid strength at each POI. Due to the combination nature, such weakness analysis may be time-consuming when identifying the weakest combination of POIs from a large number of potential candidates in realistic power grids. To address this concern, the impact of the power network structure on grid strength is analyzed in this paper. It is found that the impact mainly depends on the impedance ratios at POIs. The findings can be summarized as two criteria to develop a recursive method for fast identification of the weakest combination in this paper. The efficacy of the proposed method is demonstrated through case studies on the IEEE 39-bus system and a realistic power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Black Start Allocation for Power System Restoration

Equipment failures, operator errors, natural disasters and cyber-attacks can and have caused extended blackouts of the electric grid. Even though such events are rare, preparedness for them is critical because extended power outages endanger human lives, compromise national security, or result in economic losses of billions of dollars. Since most of the generating units cannot restart without connecting to an energized grid, the system operator relies on a few units with the ability to start autonomously, called Black Start (BS) units, to restore the power system. Allocating and maintaining these units is costly and can severely impact the restoration security and time. We formulate an optimization problem to optimally allocate BS units in the grid, while simultaneously optimizing over the restoration sequence. We extend existing optimal allocation models by including grid considerations such as active power nodal balance, transmission switching, nodal reactive power support and voltage limits. In order to aid the branch and bound tree that solves the resulting large scale mixed integer program, we propose a randomized heuristic that is executed multiple times in parallel on a high-performance computing environment to find feasible solutions. Here, we proceed to solve the IEEE-39, the IEEE-118, and a simplified WECC system with 225 nodes and 136 generators to near optimality.

97 MATHEMATICS AND COMPUTING↗

An Innovative Energy Management System for Microgrids with Multiple Grid-Forming Inverters

As increasingly more grid-forming (GFM) inverter-based resources replace traditional fossil-fueled synchronous generators as the GFM sources in microgrids, the existing microgrid energy management systems (EMS) need to be updated to control and coordinate multiple GFM inverters that consider system control objectives under different microgrid connection states. For each state, we formulate an optimization problem and apply a real-time feedback-based control algorithm; altogether, the control algorithms seamlessly connect the states into a generic microgrid EMS that controls the nodal voltages and frequencies, becomes a virtual power plant (VPP) when connected to the main grid, and coordinates power sharing responsibility among GFM sources when islanded. We showcase the EMS on a real-world simulation of a microgrid under the different states to demonstrate its operational effectiveness.

energy management systems↗

An Innovative Energy Management System for Microgrids with Multiple Grid-Forming Inverters

As increasingly more grid-forming (GFM) inverter-based resources replace traditional fossil-fueled synchronous generators as the GFM sources in microgrids, the existing microgrid energy management systems (EMS) need to be updated to control and coordinate multiple GFM inverters that consider system control objectives under different microgrid connection states.For each state, we formulate an optimization problem and apply a real-time feedback-based control algorithm; altogether, the control algorithms seamlessly connect the states into a generic microgrid EMS that controls the nodal voltages and frequencies, becomes a virtual power plant (VPP) when connected to the main grid, and coordinates power sharing responsibility among GFM sources when islanded. We showcase the EMS on a real-world simulation of a microgrid under the different states to demonstrate its operational effectiveness.

energy management system↗

Electric Vehicles and the Electric Grid

In response to the need for the decarbonization of the transport sector and to reduce the reliance on fossil fuels, it is expected that large fleets of plug-in electric vehicles (PEVs) will constitute an important share of the electricity demand in the not so distant future. These devices can, and would behave as any regular demand if they are allowed to charge as soon as they are connected to the electric grid. If such charging process is allowed, then several adverse impacts on the power grids such as increased system-wide peak demand, and early reinforcements of the distribution, transmission and/or generation systems would be required. However, as opposed to conventional demands, these new devices are equipped with a battery that enables them deferring their needs for electric energy in time. If the pliant nature of this demand is exploited in such a way that the charging of these devices takes place when it is more convenient for the power system, then not only would the adverse impacts to the system would be avoided, but also, a new stream of services could be offered to the electric power grid in the form of demand response, power injections in V2G and regulating reserves. This article discusses the consequences of integrating significant volumes of PEVs into power systems, in both, uncontrolled and controlled manners.

Ortega Vazquez, Miguel A.↗

Discrete and Integrated Solutions for Hybrid PV Plants Without Momentary Cessation in Low SCR and High Penetration PE Grids

With the increased penetration of power electronic (PE) based loads and sources, advanced solutions may be required for the enhancement of grid stability in regions with low short circuit ratio (SCR) and high penetration PE grids. The requirement of advanced solutions arises from the gradual paradigm shift of the electric grid from the traditional electric machine dominant system to a high penetration of PE-based system. One of the major challenges with such systems in recent times is the momentary cessation during alternating current (ac) grid transmission faults. During momentary cessation, PE-based resources cease to operate, thus creating probable reliability challenges for the grid. In this paper, potential feasible options to provide continuity of operation during such scenarios are presented. The options are considered through identifying upgrades in existing and upcoming discrete development of photovoltaic (PV) and energy storage systems (ESS) termed as discrete hybrid PV plants. Additionally, an advanced concept of integrated development of PV and ESS connecting to ac transmission grid links called multi-port autonomous reconfigurable solar power plant (MARS) is evaluated. The developed new solutions are evaluated for different grid use cases and scenarios in PSCAD.

Marthi, Phani Ratna Vanamali↗

2025 California Demand Response Potential Study - Charting California’s Demand Response Future. Final Report on Phase 2 Results

California’s legislative and regulatory goals for renewable energy are changing the power grid’s dynamics. Increased variable generation resource penetration connected to the bulk power system, as well as, distributed energy resources (DERs) connected to the distribution system affect the grid’s reliable operation over many different time scales (e.g., days to hours to minutes to seconds). As the state continues this transition, it will require careful planning to ensure resources with the right characteristics are available to meet changing grid management needs. Demand response (DR) has the potential to provide important resources for keeping the electricity grid stable and efficient, to defer upgrades to generation, transmission and distribution systems, and to deliver customer economic benefits. This study estimates the potential size and cost of future DR resources for California’s three investor-owned utilities (IOUs): Pacific Gas and Electric Company (PG&E), Southern California Edison Company (SCE), and San Diego Gas & Electric Company (SDG&E). Our goal is to provide data-driven insights as the California Public Utilities Commission (CPUC) evaluates how to enhance DR’s role in meeting California’s resource planning needs and operational requirements. We address two fundamental questions: 1. What cost-competitive DR service types will meet California’s future grid needs as it moves towards clean energy and advanced infrastructure? 2. What is the size and cost of the expected resource base for the DR service types?

24 POWER TRANSMISSION AND DISTRIBUTION↗