Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Resolutions Optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Spectral Analysis of PG 1034+001, the Exciting Star of Hewett 1

PG 1034+001 is an extremely hot, helium-rich DO-type star that excites the planetary nebula Hewett 1 and large parts of the surrounding interstellar medium. We present preliminary results of an ongoing spectral analysis by means of non-LTE model atmospheres that consider most elements from hydrogen to nickel. This analysis is based on high-resolution ultraviolet (FUSE, IUE) and optical (VLT/UVES, KECK) data. The results are compared with those of PG 1034+001's spectroscopic twin, the DO star PG 0038+ 199. Keywords. stars: abundances, stars: AGB and post-AGB, stars: atmospheres, stars: evolution, stars: individual (PG 1034+001, PG 0038+ 199), planetary nebulae: individual (Hewett 1)

Kruk, J. W.↗

Low-Energy Microfocus X-Ray Source for Enhanced Testing Capability in the Stray Light Facility

Research toward high-resolution, soft x-ray optics (mirrors and gratings) necessary for the next generation large x-ray observatories requires x-ray testing using a low-energy x-ray source with fine angular size (<1 arcsecond). To accommodate this somewhat demanding requirement, NASA Marshall Space Flight Center (MSFC) has procured a custom, windowless low-energy microfocus (approximately 0.1 mm spot) x-ray source from TruFocus Corporation that mates directly to the Stray Light Facility (SLF). MSFC X-ray Astronomy team members are internationally recognized for their expertise in the development, fabrication, and testing of grazing-incidence optics for x-ray telescopes. One of the key MSFC facilities for testing novel x-ray instrumentation is the SLF. This facility is an approximately 100-m-long beam line equipped with multiple x-ray sources and detectors. This new source adds to the already robust compliment of instrumentation, allowing MSFC to support additional internal and community x-ray testing needs.

Gaskin, Jessica↗

The X-ray Integral Field Unit (X-IFU) for Athena

Athena is designed to implement the Hot and Energetic Universe science theme selected by the European Space Agency for the second large mission of its Cosmic Vision program. The Athena science payload consists of a large aperture high angular resolution X-ray optics (2 m2 at 1 keV) and twelve meters away, two interchangeable focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide Field Imager. The X-IFU is a cryogenic X-ray spectrometer, based on a large array of Transition Edge Sensors (TES), oering 2.5 eV spectral resolution, with approximately 5" pixels, over a field of view of 5' in diameter. In this paper, we present the X-IFU detector and readout electronics principles, some elements of the current design for the focal plane assembly and the cooling chain. We describe the current performance estimates, in terms of spectral resolution, effective area, particle background rejection and count rate capability. Finally, we emphasize on the technology developments necessary to meet the demanding requirements of the X-IFU, both for the sensor, readout electronics and cooling chain.

X-ray↗

Giant Planet Atmospheres: Dynamics and Variability from UV to Near-IR Hubble and Adaptive Optics Imaging

Abstract: Each of the giant planets, Jupiter, Saturn, Uranus, and Neptune, has been observed by at least one robotic spacecraft mission. However, these missions are infrequent; Uranus and Neptune have only had a single flyby by Voyager 2. The Hubble Space Telescope, particularly the Wide Field Camera 3 (WFC3) and Advanced Camera for Surveys (ACS) instruments, and large ground-based telescopes with adaptive optics systems have enabled high spatial resolution imaging at a higher cadence, and over a longer time, than can be achieved with targeted missions to these worlds. These facilities offer a powerful combination of high spatial resolution, often <0.05”, and broad wavelength coverage, from the ultraviolet through the near infrared, resulting in compelling studies of the clouds, winds, and atmospheric vertical structure. This coverage allows comparisons of atmospheric properties between the planets, as well as in different regions across each planet. Temporal variations in winds, cloud structure, and color over time scales of days to years, have been measured for all four planets. With several decades of data already obtained, we can now begin to investigate seasonal influences on dynamics and aerosol properties, despite orbital periods ranging from 12 to 165 years. Future facilities will enable even greater spatial resolution and, combined with our existing long record of data, will continue to advance our understanding of atmospheric evolution on the giant planets.

Amy A Simon↗

WET Water Resources: A Google Earth Engine Python API Tool to Automate Wetland Extent Mapping Using Radar Satellite Sensors for Wetland Management and Monitoring

Wetland ecosystems are annually or seasonally wet transition zones between land and water. They provide a range of ecosystem services such as water filtration, flood mitigation, and carbon sequestration, as well as hosting biodiversity hotspots. Although they fulfill fundamental physical and natural processes, wetland extent and health are threatened by anthropogenic influences related to urbanization, population increase, pollution, and climate change. Recognizing the need to quantitatively monitor changes in these recently threatened ecosystems in a timely and cost-effective way, we developed a Google Earth Engine (GEE) Python API tool for automated wetland extent mapping using optical and radar satellite sensors that can be applied globally. The tool will significantly improve wetland change analysis and monitoring as the optical and SAR data proves high resolution (5-10 m) imagery, and SAR data is unaffected by cloud cover and light availability (day vs. night), which are common limitations for other remotely sensed sensors. The tool utilizes Copernicus Sentinel-1 C-band and NISAR L-band synthetic aperture radar (SAR) imagery. During image preprocessing, we applied a MODIS snow mask product to mask global snow coverage, which would affect land classification sensitivity. Calibration and validation were conducted through a historical change and sensitivity analysis of the Sudd watershed located in central Sudan. The tool was the first of its kind, as it enables NISAR data processing through an open-source GEE repository, further expanding and improving the utility of NASA Earth observations and contributing to NASA Open Science initiatives. We anticipate the tool will be used by researchers and practitioners interested in wetland monitoring and management..

Lori Berberian↗

MOA-2011-BLG-293LB: First microlensing planet possibly in the habitable zone

We used Keck adaptive optics observations to identify the first planet discovered by microlensing to lie in or near the habitable zone, i.e., at projected separation r = 1.1 ± 0.1 AU from its M{sub L} = 0.86 ± 0.06 M {sub ☉} host, being the highest microlensing mass definitely identified. The planet has a mass m{sub p} = 4.8 ± 0.3 M {sub Jup}, and could in principle have habitable moons. This is also the first planet to be identified as being in the Galactic bulge with good confidence: D{sub L} = 7.72 ± 0.44 kpc. The planet/host masses and distance were previously not known, but only estimated using Bayesian priors based on a Galactic model. These estimates had suggested that the planet might be a super-Jupiter orbiting an M dwarf, a very rare class of planets. We obtained high-resolution JHK images using Keck adaptive optics to detect the lens and so test this hypothesis. We clearly detect light from a G dwarf at the position of the event, and exclude all interpretations other than that this is the lens with high confidence (95%), using a new astrometric technique. The calibrated magnitude of the planet host star is H{sub L} = 19.16 ± 0.13. We infer the following probabilities for the three possible orbital configurations of the gas giant planet: 53% to be in the habitable zone, 35% to be near the habitable zone, and 12% to be beyond the snow line, depending on the atmospherical conditions and the uncertainties on the semimajor axis.

79 ASTRONOMY AND ASTROPHYSICS↗

ROSAT observations and correlated X-ray, radio, and optical features in cluster cooling flows

Images from the Rosat high resolution imager (HRI) of the central regions of cluster cooling flows are compared to optical continuum and radio continuum images. The radio sources associated with cooling flows show two distinct morphologies. In most sources, the jets appear to be inflating distinct lobes of radio plasma. These sources show strong Faraday rotation, radio pressures in agreement with the X-ray gas pressure, and a radio X-ray spatial anti-correlation. A few cooling sources are seen to have amorphous radio morphologies, Faraday depolarization, low radio pressure and a possible radio-X-ray spatial correlation. These properties suggest that the radio jets are disrupted and that the radio plasma is mixed with the thermal X-ray plasma. Blue continuum lobes are seen in several cooling flow central galaxies. These could be due to star formation induced by the hydrodynamical effects of the radio source or due to the scattered light from beamed emission from the active galactic nucleus.

Sarazin, C. L.↗

Shadowgraph Study of Gradient Driven Fluctuations

A fluid or fluid mixture, subjected to a vertical temperature and/or concentration gradient in a gravitational field, exhibits greatly enhanced light scattering at small angles. This effect is caused by coupling between the vertical velocity fluctuations due to thermal energy and the vertically varying refractive index. Physically, small upward or downward moving regions will be displaced into fluid having a refractive index different from that of the moving region, thus giving rise to the enhanced scattering. The scattered intensity is predicted to vary with scattering wave vector q, as q(sup -4), for sufficiently large q, but the divergence is quenched by gravity at small q. In the absence of gravity, the long wavelength fluctuations responsible for the enhanced scattering are predicted to grow until limited by the sample dimensions. It is thus of interest to measure the mean-squared amplitude of such fluctuations in the microgravity environment for comparison with existing theory and ground based measurements. The relevant wave vectors are extremely small, making traditional low-angle light scattering difficult or impossible because of stray elastically scattered light generated by optical surfaces. An alternative technique is offered by the shadowgraph method, which is normally used to visualize fluid flows, but which can also serve as a quantitative tool to measure fluctuations. A somewhat novel shadowgraph apparatus and the necessary data analysis methods will be described. The apparatus uses a spatially coherent, but temporally incoherent, light source consisting of a super-luminescent diode coupled to a single-mode optical fiber in order to achieve extremely high spatial resolution, while avoiding effects caused by interference of light reflected from the various optical surfaces that are present when using laser sources. Results obtained for a critical mixture of aniline and cyclohexane subjected to a vertical temperature gradient will be presented. The sample was confined between two horizontal parallel sapphire plates with a vertical spacing of 1 mm. The temperatures of the sapphire plates were controlled by independent circulating water loops that used Peltier devices to add or remove heat from the room air as required. For a mixture with a temperature gradient, two effects are involved in generating the vertical refractive index gradient, namely thermal expansion and the Soret effect, which generates a concentration gradient in response to the applied temperature gradient. For the aniline/cyclohexane system, the denser component (aniline) migrates toward the colder surface. Consequently, when heating from above, both effects result in the sample density decreasing with altitude and are stabilizing in the sense that no convective motion occurs regardless of the magnitude of the applied temperature gradient. The Soret effect is strong near a binary liquid critical point, and thus the dominant effect is due to the induced concentration gradient. The results clearly show the divergence at low q and the predicted gravitational quenching. Results obtained for different applied temperature gradients at varying temperature differences from the critical temperature, clearly demonstrate the predicted divergence of the thermal diffusion ratio. Thus, the more closely the critical point is approached, the smaller becomes the temperature gradient required to generate the same signal. Two different methods have been used to generate pure concentration gradients. In the first, a sample cell was filled with a single fluid, ethylene glycol, and a denser miscible fluid, water, was added from below thus establishing a sharp interface to begin the experiment. As time went on the two fluids diffused into each other, and large amplitude fluctuations were clearly observed at low q. The effects of gravitational quenching were also evident. In the second method, the aniline/cyclohexane sample was used, and after applying a vertical temperature gradient for several hours, the top and bottom temperatures were set equal and the thermal gradient died on a time scale of seconds, leaving the Soret induced concentration gradient in place. Again, large-scale fluctuations were observed and died away slowly in amplitude as diffusion destroyed the initial concentration gradient.

Cannell, David↗

Developing a narrow-line laser spectrometer based on a tunable continuous-wave dye laser

We present the development of a dye-laser-based spectrometer operating at 550–600 nm. The spectrometer will be used to detect an ultra-narrow clock transition ({sup 1}S{sub 0}-{sup 3}P{sub 0}) in an Ytterbium optical lattice clock and perform high-resolution spectroscopy of iodine molecules trapped in the sub-nanometer channels of zeolite crystal (AlPO{sub 4}-11). Two-stage Pound-Drever-Hall frequency stabilization is implemented on the tunable continuous-wave dye laser to obtain a reliable operation and provide stable laser radiations with two different spectral linewidths. In the first-stage frequency locking, a compact home-built intracavity electro-optic modulator is adopted for suppressing fast frequency noise. With an acquisition time of 0.1 s the 670-kHz linewidth of the free-running dye laser is reduced to 2 kHz when locked to a pre-stabilization optical cavity with a finesse of 1170. When the pre-stabilized laser is locked to a high-finesse optical cavity, a linewidth of 1.4 Hz (2 s) is observed and the frequency stability is 3.7 × 10{sup −15} (3 s). We also measure and analyze the individual noise contributions such as those from residual amplitude modulation and electronic noise. The ongoing upgrades include improving long-term frequency stability at time scales from 10 to 100 s and implementing continuous frequency scan across 10 GHz with radio-frequency precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Astronomical observations with normal incidence multilayer optics - Recent results and future prospects

High-resolution X-ray and EUV images of the solar corona have been obtained with two rocket-borne normal incidence Cassegrain multilayer telescopes. The Cassegrain images correspond to material at about 10 to the 6th K and about 80,000 K. Other images, at somewhat lower resolution, were obtained with Herschelian multilayer telescopes and Wolter-Schwarzschild hybrid grazing incidence/multilayer optical systems. The Cassegrain and Herschelian images are discussed emphasizing the analysis of polar plumes observed at the limb of the sun. The application of specific multilayer techniques to astronomical observations is discussed, emphasizing observations of the sun. Current efforts to develop a comprehensive Multi-Spectral Solar Telescope Array rocket instrument for the study of a wide variety of problems related to the solar atmosphere are reported.

Walker, Arthur B. C., Jr.↗

Multimodal Tip-Enhanced Nonlinear Optical Nanoimaging of Plasmonic Silver Nanocubes

Optical field localization at plasmonic tip-sample nanojunctions has enabled high spatial resolution chemical analysis through tip-enhanced linear optical spectroscopies, including Raman scattering and photoluminescence. In this work, we illustrate that nonlinear optical processes, including parametric four-wave mixing (4WM), second harmonic/sum-frequency generation (SHG and SFG), and two-photon photoluminescence (TPPL), can be enhanced at plasmonic junctions and spatio-spectrally resolved simultaneously with few-nm spatial resolution under ambient conditions. More importantly, through a detailed analysis of our spectral nano-images, we find that the efficiencies of the local nonlinear signals are determined by sharp tip-sample junction resonances that vary over the few-nanometer length scale because of the corrugated nature of the probe. Namely, plasmon resonances centered at or around the different nonlinear signals are tracked through TPPL, and they are found to selectively enhance nonlinear signals with closely matched optical resonances.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Methods of improving spatial resolution for IR spectroscopy in atmospheric-pressure plasma systems

High-temperature, atmospheric pressure plasma systems operated in molecular gases present complex diagnostic challenges. Infrared spectroscopy has been used to make measurements of the absorbance spectrum of complex molecular gas mixtures and thereby calculate the concentrations and species temperatures in these systems. For atmospheric-pressure systems, high spatial gradients arise and high spatial-resolution measurements are thus desirable. Some systems have achieved increased spatial resolution by reducing the beam diameter. However, this increase in spatial resolution comes at the expense of the optical throughput. Here we propose modifying a commercial Fourier Transform, Infrared spectrometer system with a set of simple optical elements. This design allows for scannable, high spatial resolution absorbance spectrum measurements of a complex molecular gas mix. We analyze the signal-to-noise ratio for this design and compare it with the diameter reduction method. For sufficiently low plasma radiation levels, this design improves the signal-to-noise ratio relative to reducing the beam diameter size while transmitting nearly all of the beam power. Furthermore, whether this design can achieve the desired sub-mm spatial resolution depends on the radiating area of the infrared light source in the spectrometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reconstruction of the Hubble Space Telescope mirror figure from out-of-focus stellar images

Both the amplitude and the phase of the incoming wave front viewed from the focal plane are reconstructed from the illumination recorded in defocused stellar images taken in flight by the HST. The reconstructed wavefront surface shows very little aberration. Compared to geometrical optics methods, the technique produces high spatial resolution wavefront maps with images taken closer to the telescope's focal plane. For the HST, the quality of the wavefront reconstruction is limited by the telescope jitter. The technique cannot be applied to ground-based telescopes at optical wavelength where the image is heavily blurred by the atmosphere. It is argued to be promising as a diagnostic tool for optical telescopes in space.

Roddier, C.↗

Synthesis and crystal structure characterization of InGaZnO{sub 4} with a new defect structure

Single crystals of InGaZnO{sub 4} were synthesized in a sealed Pt-tube at elevated temperatures under normal pressure without flux. InGaZnO{sub 4} has a trigonal crystal system (R3{sup ¯}m; No. 166) deduced from convergent beam electron diffraction (CBED). Single crystal structure refinement from XRD data at −150 °C (a=3.275(1) Å; c=25.99(1) Å; Z=3) revealed an alternate stacking of InO{sub 6/3}{sup −} and (Ga,Zn)O{sub 4/4}{sup +} layers, iso-structural to YbFe{sub 2}O{sub 4}. The cell parameters at room temperature were refined from powder X-ray diffraction data (a=3.284(3) Å and c=26.037(3) Å). The transparent crystals have a gray-bluish color and exhibit an excess of Ga expressed by the cation ratio of In:Ga:Zn=30.2(9):39(1):31(1) determined by energy dispersive X-ray spectroscopy (EDXS). While the isovalent substitution of In{sup 3+} by Ga{sup 3+} is known, an additional aliovalent substitution of Zn{sup 2+} by Ga{sup 3+} is observed. This results in the formula (In{sub 0.9}Ga{sub 0.1})Ga{sub 1.06}Zn{sub 0.91}□{sub 0.03}O{sub 4} where 3% of the cations in 4+1 coordination are vacant due to aliovalent substitution. Further evidence of that defect structure is found in the lattice parameter a which is substantially smaller than in stoichiometric InGaZnO{sub 4}, as well as in the strong absorption in the near-IR from transitions correlated with the defect structure. The bluish color of the crystals is due to an enhanced absorption in the red of the visible spectrum. For the first time, we achieved to image InGaZnO{sub 4} at atomic resolution in the electron microscope proving a perfect periodic stacking of atomic layers. - Graphical abstract: Single crystals of InGaZnO{sub 4} have been synthesized at ambient pressure and analyzed with X-ray diffraction, electron microscopy, and optical absorption. Optical band gap and optical transmission have been determined. - Highlights: • Preparation of single crystals of InGaO{sub 3}(ZnO){sub 1} at ambient pressure for the first time. • Non-stoichiometric compound (In{sub 0.9}Ga{sub 0.1})Ga{sub 1.06}Zn{sub 0.91}□{sub 0.03}O{sub 4} with defect structure, excess of Ga, depletion of Zn. • Real structure of InGaO{sub 3}(ZnO){sub 1} imaged by high resolution TEM for the first time. • Optical band gap and transmission of InGaO{sub 3}(ZnO){sub 1} single crystal.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved Cloud and Snow Screening in MAIAC Aerosol Retrievals Using Spectral and Spatial Analysis

An improved cloud/snow screening technique in the Multi-Angle Implementation of Atmospheric Correction (MAIAC) algorithm is described. It is implemented as part of MAIAC aerosol retrievals based on analysis of spectral residuals and spatial variability. Comparisons with AERONET aerosol observations and a large-scale MODIS data analysis show strong suppression of aerosol optical thickness outliers due to unresolved clouds and snow. At the same time, the developed filter does not reduce the aerosol retrieval capability at high 1 km resolution in strongly inhomogeneous environments, such as near centers of the active fires. Despite significant improvement, the optical depth outliers in high spatial resolution data are and will remain the problem to be addressed by the application-dependent specialized filtering techniques.

Lyapustin, A.↗

DETECTION OF SUPERGRANULATION ALIGNMENT IN POLAR REGIONS OF THE SUN BY HELIOSEISMOLOGY

We report on a new phenomenon of 'alignment' of supergranulation cells in the polar regions of the Sun. Recent high-resolution data sets obtained by the Solar Optical Telescope on board the Hinode satellite enabled us to investigate supergranular structures in high-latitude regions of the Sun. We have carried out a local helioseismology time-distance analysis of the data and detected acoustic travel-time variations due to the supergranular flows. The supergranulation cells in both the north and south polar regions show systematic alignment patterns in the north-south direction. The south-pole data sets obtained in a month-long Hinode campaign indicate that the supergranulation alignment property may be quite common in the polar regions. We also discuss the latitudinal dependence of the supergranulation cell sizes; the data show that the east-west cell size decreases toward higher latitudes.

79 ASTRONOMY AND ASTROPHYSICS↗

High resolution Cerenkov light imaging of induced positron distribution in proton therapy

Purpose: In proton therapy, imaging of the positron distribution produced by fragmentation during or soon after proton irradiation is a useful method to monitor the proton range. Although positron emission tomography (PET) is typically used for this imaging, its spatial resolution is limited. Cerenkov light imaging is a new molecular imaging technology that detects the visible photons that are produced from high-speed electrons using a high sensitivity optical camera. Because its inherent spatial resolution is much higher than PET, the authors can measure more precise information of the proton-induced positron distribution with Cerenkov light imaging technology. For this purpose, they conducted Cerenkov light imaging of induced positron distribution in proton therapy. Methods: First, the authors evaluated the spatial resolution of our Cerenkov light imaging system with a {sup 22}Na point source for the actual imaging setup. Then the transparent acrylic phantoms (100 × 100 × 100 mm{sup 3}) were irradiated with two different proton energies using a spot scanning proton therapy system. Cerenkov light imaging of each phantom was conducted using a high sensitivity electron multiplied charge coupled device (EM-CCD) camera. Results: The Cerenkov light’s spatial resolution for the setup was 0.76 ± 0.6 mm FWHM. They obtained high resolution Cerenkov light images of the positron distributions in the phantoms for two different proton energies and made fused images of the reference images and the Cerenkov light images. The depths of the positron distribution in the phantoms from the Cerenkov light images were almost identical to the simulation results. The decay curves derived from the region-of-interests (ROIs) set on the Cerenkov light images revealed that Cerenkov light images can be used for estimating the half-life of the radionuclide components of positrons. Conclusions: High resolution Cerenkov light imaging of proton-induced positron distribution was possible. The authors conclude that Cerenkov light imaging of proton-induced positron is promising for proton therapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗