Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Implanting Transition Metal into Li 2 O-Based Cathode Prelithiation Agent for High-Energy-Density and Long-Life Li-Ion Batteries

Compensating the irreversible loss of limited active lithium (Li) is essentially important for improving the energy-density and cycle-life of practical Li-ion battery full-cell, especially after employing high-capacity but low initial coulombic efficiency anode candidates. Introducing prelithiation agent can provide additional Li source for such compensation. Herein, we precisely implant trace Co (extracted from transition metal oxide) into the Li site of Li 2 O, obtaining (Li 0.66 Co 0.11$\square$0.23 ) 2 O (CLO) cathode prelithiation agent. Further, the synergistic formation of Li vacancies and Co-derived catalysis efficiently enhance the inherent conductivity and weaken the Li-O interaction of Li 2 O, which facilitates its anionic oxidation to peroxo/superoxo species and gaseous O 2 , achieving 1642.7 mAh/g ~Li2O prelithiation capacity (≈980 mAh/g for prelithiation agent). Coupled 6.5 wt % CLO-based prelithiation agent with LiCoO 2 cathode, substantial additional Li source stored within CLO is efficiently released to compensate the Li consumption on the SiO/C anode, achieving 270 Wh/kg pouch-type full-cell with 92 % capacity retention after 1000 cycles.

25 ENERGY STORAGE↗

Juvenile Chinook Salmon Survival When Exposed to Simulated Dam Passage after Being Implanted with a New Microacoustic Transmitter

The current minimum size for tagging Chinook Salmon Oncorhynchus tshawytscha with acoustic transmitters is = 95 mm fork length (FL). Using a new injectable acoustic transmitter (AT), our objective was to determine a minimum size for tagging Chinook Salmon. We measured survival and transmitter and tissue retention after exposure to rapid pressure changes (n = 399) or shear forces (n = 308). Fish (69–107 mm FL) were implanted with an AT (0.22 g; AT-only) or an AT and a passive integrated transponder (PIT; 0.10 g; AT+PIT) tag through a 3-mm incision with no sutures, or did not receive an incision or tag (control). Survival and transmitter and tissue retention following pressure changes was significantly lower for AT-only (0.70) and AT+PIT (0.54) fish compared to controls (0.85). No transmitters were expelled but 2.2% of AT-only and 12.5% of AT+PIT fish had tissue or a transmitter protruding. Following shear exposure, survival and transmitter and tissue retention was significantly lower for AT-only (0.70) and AT+PIT (0.61) fish compared to controls (0.98). Here, tissue expulsion described 87% of AT-only and 80% of AT+PIT mortalities. In both tests fish larger than 85–88 mm FL had a higher probability of survival and tissue and transmitter retention than smaller fish. We recommend the minimum size for tagging continue to be 95 mm FL, using a 3-mm incision with no sutures.

59 BASIC BIOLOGICAL SCIENCES↗

Scheme for Creating a Subcutaneous Tunnel to Place an Indwelling Implantable Central Venous Access System in the Forearm

We report a method that we have devised in which a secure subcutaneous tunnel is prepared during the placement of an indwelling central venous reservoir in the forearm. Subjects included 69 cases in which a procedure for implanting an indwelling reservoir in the forearm was performed between June 2006 and May 2007. For the subcutaneous tunnel, a 22-G Cathelin needle was advanced from the puncture site, turning toward the subcutaneous pocket side to the deep subcutaneous area. A 14-G Surflo IV catheter was then advanced along the 22-G Cathelin needle from the subcutaneous pocket. With the tip of the 14-G Surflo IV catheter emerging above the skin at the puncture site, the inner needle of the 14-G Surflo IV catheter and the 22-G Cathelin needle were removed. The catheter was passed through the outer 14-G Surflo IV catheter to emerge on the subcutaneous pocket site, then the outer needle of the Surflo catheter was also removed, and a connection to the port was made to create the subcutaneous tunnel. In all 69 cases, the subcutaneous tunnel in the forearm of the nondominant arm was successfully created within a short period of time (100% success rate). No problems were observed due to slack in the catheter until removal of the sutures 1 week later and for 3 months after treatment. With this method, we believe that a subcutaneous tunnel can be prepared in which the contained catheter has minimal freedom of movement, and which minimizes any damage induced by slack in the catheter within the subcutaneous tunnel.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Late Pseudocoarctation Syndrome After Stent-Graft Implantation For Traumatic Aortic Rupture

The present observation illustrates an unusual complication occurring after stent-grafting (S-graft) for aortic isthmus rupture. A 22-year-old patient, treated by S-graft in the emergency department for traumatic aortic rupture, was readmitted 10 months later with pseudocoarctation syndrome. A membrane was found inside the stent-graft that had induced a pseudo-dissection, which caused the pseudocoarctation syndrome. Surgical treatment consisted of removing the stent-graft and membrane and replacing it with a vascular implant. The patient's clinical course was fair. The suggested mechanism was circumferential neoendothelialization of the stent-graft. Dehiscence caused the superior part of the membrane to drop into the lumen of the stent-graft creating a 'false channel' that compressed the 'true lumen' and induced 'pseudocoarctation' syndrome. The cause of the extensive neointimalization remains unexplained. Thoracic aortic stent-grafts require regular follow-up monitoring by angioscan or angio-magnetic resonance imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study of the Biocompatibility of Titanium-Niobium Implants by the Parameters of Their Osseointegration under Experimental Conditions

Superelastic titanium alloys (titanium-niobium-zirconium and titanium-niobium-tantalum) are considered to be the more advantageous choice for dental implants than titanium alloys due to their physico-mechanical properties close to those of the bone tissue. Morphological studies of the biocompatibility of these alloys in comparison with titanium were carried out in vivo. Scanning electron microscopy and microprobe elemental analysis of the tissue along the interface between the bone and titanium/superelastic titanium alloys showed similar morphology and elemental composition both on days 30 (poorly mineralized connective tissue was detected in sites of contact with titanium alloy samples) and 90 after surgery (the surface of the titanium alloy samples was covered with mineralized tissue similar by its composition to the surrounding bone).

60 APPLIED LIFE SCIENCES↗

Characterization of the Surface of Silver Ion-Implanted Silicon by Optical Reflectance

The optical reflection of the surface of silicon implanted with Ag{sup +} ions at low energy of 30 keV in a wide dosage range of 5.0·10{sup 14}–1.5·10{sup 17} ion/cm{sup 2} was studied in parallel with electron microscopy observation of the samples. It was found that with increasing ion dose of irradiation, the reflection intensity in the UV range of the Si spectrum decreases monotonically due to amorphization and macrostructuring of Si near-surface layer. In the long-wavelength region of the reflection spectra, a selective band with a maximum near 830 nm is recorded due to the plasmon resonance of ion-synthesized Ag nanoparticles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

DIN 1.7035 Steel Modification with High Intensity Nitrogen Ion Implantation

The paper presents research results on the formation of deep ion-modified layers of the grade DIN 1.7035 alloy steel due to a high intensity, repetitively-pulsed nitrogen ion beams with the ion current density of up to 0.5 А/сm{sup 2}. The formation of a low-energy, high intensity nitrogen ion beam is based on a plasma immersion ion extraction followed by the ballistic focusing in the equipotential drift region. The nitrogen ion implantation in steel specimens is performed at a 1.2 keV energy and 450, 500, 580 and 650°С temperatures during 60 minutes. The morphology, elementary composition and mechanical properties are investigated in deep layers of steel specimens alloyed with nitrogen ions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Influence of Process-Induced Anisotropy and Synovial Environment on Wear of EBM Built Ti6Al4V Joint Implants

Additive manufacturing (AM) technology is identified as an ideal solution to overcome challenges in design and manufacturing of complex components. However, the layered fashion of AM process result in directionally solidified microstructures on the system. The anisotropic surface texture will affect wear and corrosion resistance. The current study investigates tribological responses of AM-made Ti6Al4V for joint implant applications during the combined effect from synovial lubrication and process-induced surface structure on surface fatigue damage response. Electron beam melting was used to produce Ti6Al4V specimens and mechanical characterizations were performed using nanoindentation and micro bending tests to determine their mechanical properties. A series of pin-on-disk wear tests were performed to quantify sliding contact fatigue damage in three simulated synovial fluids with variable concentrations of bovine serum albumin and hyaluronic acid in the PBS solution. Physical properties of simulated synovial fluids were measured using a nanoindenter-based technique and correlated to fatigue wear response. The lower wear rate is found in greater protein concentrations. The results presented AM build direction significantly affects sliding fatigue wear resistance on TI6Al4V surface in all synovial environments.

36 MATERIALS SCIENCE↗

Potential effects of low-dose average CT on cardiac implantable electronic devices

Background: Average CT has been shown to be more accurate than conventional helical CT in quantitation of the PET data. The risk of CT irradiation of a cardiac implantable electronic device (CIED) causing an adverse event is low and is generally outweighed by the clinical benefit of a medically indicated examination. However, irradiation of CIED over one breath cycle in cine CT scan for average CT could impose risks on a patient who is pacing dependent. The purpose of this study was to demonstrate that low-dose average CT can be safe for CIED. Methods: A Medtronic CIED of model Protecta VR was submerged in a saline bath for a series of 4-s cine CT scans on a GE CT scanner programmed to deliver a 2-cm-wide radiation at a dose rate of 0.9 to 41.2 mGy/s to the CIED. The number of over-sensings was recorded as the interference of radiation to the CIED. Results: Dose rates ≥ 1.9 mGy/s caused over-sensing. The higher the dose rate, the more over-sensings there were. The lowest dose rate of 0.9 mGy/s did not cause any over-sensing. Conclusions: Low-dose average CT at 0.9 mGy/s can be safe for a CIED patient who is pacing dependent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Discrimination and quantification of Fe and Ni abundances in Genesis solar wind implanted collectors using X-ray standing wave fluorescence yield depth profiling with internal referencing

In this paper, X-ray standing wave fluorescence yield depth profiling was used to determine the solar wind implanted Fe and Ni fluences in a silicon-on-sapphire (SoS) Genesis collector (60326). An internal reference standardization method was developed based on fluorescence from Si and Al in the collector materials. Measured Fe fluence agreed well with that measured previously by us on a sapphire collector (50722) as well as SIMS results by Jurewicz et al. Measured Ni fluence was higher than expected by a factor of two; neither instrumental errors nor solar wind fractionation effects are considered significant perturbations to this value. Impurity Ni within the epitaxial Si layer, if present, could explain the high Ni fluences and therefore needs further investigation. As they stand, these results are consistent with minor temporally-variable Fe and Ni fractionation on the timescale of a year.

36 MATERIALS SCIENCE↗

A Comparison of Acute and Chronic Toxicity for Men With Low-Risk Prostate Cancer Treated With Intensity-Modulated Radiation Therapy or {sup 125}I Permanent Implant

Purpose: To compare the toxicity and biochemical outcomes of intensity-modulated radiation therapy (IMRT) and {sup 125}I transperineal permanent prostate seed implant ({sup 125}I) for patients with low-risk prostate cancer. Methods and Materials: Between 1998 and 2004, a total of 374 low-risk patients (prostate-specific antigen < 10 ng/ml, T1c-T2b, Gleason score of 6 or less, and no neoadjuvant hormones) were treated at Fox Chase Cancer Center (216 IMRT and 158 {sup 125}I patients). Median follow-up was 43 months for IMRT and 48 months for {sup 125}I. The IMRT prescription dose ranged from 74-78 Gy, and {sup 125}I prescription was 145 Gy. Acute and late gastrointestinal (GI) and genitourinary (GU) toxicity was recorded by using a modified Radiation Therapy Oncology Group scale. Freedom from biochemical failure was defined by using the Phoenix definition (prostate-specific antigen nadir + 2.0 ng/ml). Results: Patients treated by using IMRT were more likely to be older and have a higher baseline American Urological Association symptom index score, history of previous transurethral resection of the prostate, and larger prostate volumes. On multivariate analysis, IMRT was an independent predictor of lower acute and late Grade 2 or higher GU toxicity and late Grade 2 or higher GI toxicity. Three-year actuarial estimates of late Grade 2 or higher toxicity were 2.4% for GI and 3.5% for GU by using IMRT compared with 7.7% for GI and 19.2% for GU for {sup 125}I, respectively. Four-year actuarial estimates of freedom from biochemical failure were 99.5% for IMRT and 93.5% for {sup 125}I (p = 0.09). Conclusions: The IMRT and {sup 125}I produce similar outcomes, although IMRT appears to have less acute and late toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postmastectomy Chest Wall Radiation to a Temporary Tissue Expander or Permanent Breast Implant-Is There a Difference in Complication Rates?

Purpose: The purpose of this study was to evaluate the likelihood of complications and cosmetic results among breast cancer patients who underwent modified radical mastectomy (MRM) and breast reconstruction followed by radiation therapy (RT) to either a temporary tissue expander (TTE) or permanent breast implant (PI). Methods and Materials: Records were reviewed of 74 patients with breast cancer who underwent MRM followed by breast reconstruction and RT. Reconstruction consisted of a TTE usually followed by exchange to a PI. RT was delivered to the TTE in 62 patients and to the PI in 12 patients. Dose to the reconstructed chest wall was 50 Gy. Median follow-up was 48 months. The primary end point was the incidence of complications involving the reconstruction. Results: There was no significant difference in the rate of major complications in the PI group (0%) vs. 4.8% in the TTE group. No patients lost the reconstruction in the PI group. Three patients lost the reconstruction in the TTE group. There were excellent/good cosmetic scores in 90% of the TTE group and 80% of the PI group (p = 0.22). On multivariate regression models, the type of reconstruction irradiated had no statistically significant impact on complication rates. Conclusions: Patients treated with breast reconstruction and RT can experience low rates of major complications. We demonstrate no significant difference in the overall rate of major or minor complications between the TTE and PI groups. Postmastectomy RT to either the TTE or the PI should be considered as acceptable treatment options in all eligible patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hypofractionated Boost With High-Dose-Rate Brachytherapy and Open Magnetic Resonance Imaging-Guided Implants for Locally Aggressive Prostate Cancer: A Sequential Dose-Escalation Pilot Study

Purpose: To evaluate the feasibility, tolerance, and preliminary outcome of an open MRI-guided prostate partial-volume high-dose-rate brachytherapy (HDR-BT) schedule in a group of selected patients with nonmetastatic, locally aggressive prostatic tumors. Methods and Materials: After conventional fractionated three-dimensional conformal external radiotherapy to 64-64.4 Gy, 77 patients with nonmetastatic, locally aggressive (e.g., perineural invasion and/or Gleason score 8-10) prostate cancer were treated from June 2000 to August 2004, with HDR-BT using temporary open MRI-guided {sup 192}Ir implants, to escalate the dose in the boost region. Nineteen, 21, and 37 patients were sequentially treated with 2 fractions of 6 Gy, 7 Gy, and 8 Gy each, respectively. Neoadjuvant androgen deprivation was given to 62 patients for 6-24 months. Acute and late toxicity were scored according to the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer scoring system. Results: All 77 patients completed treatment as planned. Only 2 patients presented with Grade >=3 acute urinary toxicity. The 3-year probability of Grade >=2 late urinary and low gastrointestinal toxicity-free survival was 91.4% +- 3.4% and 94.4% +- 2.7%, respectively. Rates of 3-year biochemical disease-free survival (bDFS) and disease-specific survival were 87.1% +- 4.1% and 100%, respectively. Conclusions: Boosting a partial volume of the prostate with hypofractionated HDR-BT for aggressive prostate cancer was feasible and showed limited long-term toxicity, which compared favorably with other dose-escalation methods in the literature. Preliminary bDFS was encouraging if one considers the negatively selected population of high-risk patients in this study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Equivalent Biochemical Control and Improved Prostate-Specific Antigen Nadir After Permanent Prostate Seed Implant Brachytherapy Versus High-Dose Three-Dimensional Conformal Radiotherapy and High-Dose Conformal Proton Beam Radiotherapy Boost

Purpose: Permanent prostate implant brachytherapy (PPI), three-dimensional conformal radiotherapy (3D-CRT), and conformal proton beam radiotherapy (CPBRT) are used in the treatment of localized prostate cancer, although no head-to-head trials have compared these modalities. We studied the biochemical control (biochemical no evidence of disease [bNED]) and prostate-specific antigen (PSA) nadir achieved with contemporary PPI, and evaluated it against 3D-CRT and CPBRT. Patients and Methods: A total of 249 patients were treated with PPI at the University of California, San Francisco, and the outcomes were compared with those from a 3D-CRT cohort and the published results of a high-dose CPBRT boost (CPBRTB) trial. For each comparison, subsets of the PPI cohort were selected with patient and disease criteria similar to those of the reference group. Results: With a median follow-up of 5.3 years, the bNED rate at 5 and 7 years achieved with PPI was 92% and 86%, respectively, using the American Society for Therapeutic Radiology and Oncology (ASTRO) definition, and 93% using the PSA nadir plus 2 ng/mL definition. Using the ASTRO definition, a 5-year bNED rate of 78% was achieved for the 3D-CRT patients compared with 94% for a comparable PPI subset and 93% vs. 92%, respectively, using the PSA nadir plus 2 ng/mL definition. The median PSA nadir for patients treated with PPI and 3D-CRT was 0.10 and 0.40 ng/mL, respectively (p < .0001). For the CPBRT comparison, the 5-year bNED rate after a CPBRTB was 91% using the ASTRO definition vs. 93% for a similar group of PPI patients. A greater proportion of PPI patients achieved a lower PSA nadir compared with those achieved in the CPBRTB trial (PSA nadir <=0.5 ng/mL, 91% vs. 59%, respectively). Conclusion: We have demonstrated excellent outcomes in low- to intermediate-risk patients treated with PPI, suggesting at least equivalent 5-year bNED rates and a greater proportion of men achieving lower PSA nadirs compared with 3D-CRT or CPBRTB.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcomes of Children With Favorable Histology Wilms Tumor and Peritoneal Implants Treated in National Wilms Tumor Studies-4 and -5

Purpose: There are no published reports on the optimal management and survival rates of children with Wilms tumor (WT) and peritoneal implants (PIs). Methods and Materials: Among favorable histology WT patients enrolled in the National Wilms Tumor Study (NWTS)-4 and NWTS-5, 57 children had PIs at the time of nephrectomy. The median age was 3 years 5 months (range, 3 months to 14 years). The majority of children (42 of 57 [74%)] had Stage III tumors; 15 had Stage IV disease. All patients received multimodality therapy. Of 56 children who underwent primary surgery, 48 (84%) had gross total resection of all tumors. All patients received 3-drug chemotherapy with vincristine, dactinomycin, and doxorubicin. Whole-abdomen radiotherapy (RT) was used in 47 patients (82%), and in 50 patients (88%) the RT dose was 10.5 Gy. Results: After a median follow-up of 7.5 years, the overall abdominal and systemic tumor control rates were 97% and 93%, respectively. A comparative analysis between children with PIs and those without PIs showed no significant differences in the clinical characteristics between the two groups. The 5-year event-free survival rates with and without PIs were 90% (95% confidence interval, 78-96%) and 83% (95% confidence interval, 81-85%) respectively (p = 0.20). Conclusions: Multimodality therapy with surgery, whole-abdomen RT, and three-drug chemotherapy delivered according to the NWTS-4 and -5 protocols resulted in excellent abdominal and systemic tumor control rates. All children should be monitored in long-term surveillance programs for the early detection and management of therapy-related toxicities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Biodistribution and Toxicity Study of Cobalt Dichloride-N-Acetyl Cysteine in an Implantable MRI Marker for Prostate Cancer Treatment

Purpose: C4, a cobalt dichloride-N-acetyl cysteine complex, is being developed as a positive-signal magnetic resonance imaging (MRI) marker to localize implanted radioactive seeds in prostate brachytherapy. We evaluated the toxicity and biodistribution of C4 in rats with the goal of simulating the systemic effects of potential leakage from C4 MRI markers within the prostate. Methods and Materials: 9-μL doses (equivalent to leakage from 120 markers in a human) of control solution (0.9% sodium chloride), 1% (proposed for clinical use), and 10% C4 solution were injected into the prostates of male Sprague-Dawley rats via laparotomy. Organ toxicity and cobalt disposition in plasma, tissues, feces, and urine were evaluated. Results: No C4-related morbidity or mortality was observed in the biodistribution arm (60 rats). Biodistribution was measurable after 10% C4 injection: cobalt was cleared rapidly from periprostatic tissue; mean concentrations in prostate were 163 μg/g and 268 μg/g at 5 and 30 minutes but were undetectable by 60 minutes. Expected dual renal-hepatic elimination was observed, with percentages of injected dose recovered in tissues of 39.0 ± 5.6% (liver), >11.8 ± 6.5% (prostate), and >5.3 ± 0.9% (kidney), with low plasma concentrations detected up to 1 hour (1.40 μg/mL at 5-60 minutes). Excretion in urine was 13.1 ± 4.6%, with 3.1 ± 0.54% recovered in feces by 24 hours. In the toxicity arm, 3 animals died in the control group and 1 each in the 1% and 10% groups from surgical or anesthesia-related complications; all others survived to scheduled termination at 14 days. No C4-related adverse clinical signs or organ toxicity were observed. Conclusion: C4-related toxicity was not observed at exposures at least 10-fold the exposure proposed for use in humans. These data demonstrating lack of systemic toxicity with dual routes of elimination in the event of in situ rupture suggest that C4 warrants further investigation as an MRI marker for prostate brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rates of Reconstruction Failure in Patients Undergoing Immediate Reconstruction With Tissue Expanders and/or Implants and Postmastectomy Radiation Therapy

Objectives: Mastectomy rates for breast cancer have increased, with a parallel increase in immediate reconstruction. For some women, tissue expander and implant (TE/I) reconstruction is the preferred or sole option. This retrospective study examined the rate of TE/I reconstruction failure (ie, removal of the TE or I with the inability to replace it resulting in no final reconstruction or autologous tissue reconstruction) in patients receiving postmastectomy radiation therapy (PMRT). Methods and Materials: Between 2004 and 2012, 99 women had skin-sparing mastectomies (SSM) or total nipple/areolar skin-sparing mastectomies (TSSM) with immediate TE/I reconstruction and PMRT for pathologic stage II to III breast cancer. Ninety-seven percent had chemotherapy (doxorubicin and taxane-based), 22% underwent targeted therapies, and 78% had endocrine therapy. Radiation consisted of 5000 cGy given in 180 to 200 cGy to the reconstructed breast with or without treatment to the supraclavicular nodes. Median follow-up was 3.8 years. Results: Total TE/I failure was 18% (12% without final reconstruction, 6% converted to autologous reconstruction). In univariate analysis, the strongest predictor of reconstruction failure (RF) was absence of total TE/I coverage (acellular dermal matrix and/or serratus muscle) at the time of radiation. RF occurred in 32.5% of patients without total coverage compared to 9% with coverage (P=.0069). For women with total coverage, the location of the mastectomy scar in the inframammary fold region was associated with higher RF (19% vs 0%, P=.0189). In multivariate analysis, weight was a significant factor for RF, with lower weight associated with a higher RF. Weight appeared to be a surrogate for the interaction of total coverage, thin skin flaps, interval to exchange, and location of the mastectomy scar. Conclusions: RFs in patients receiving PMRT were lowered with total TE/I coverage at the time of radiation by avoiding inframammary fold incisions and with a preferred interval of 6 months to exchange.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Urinary and Rectal Toxicity Profiles After Permanent Iodine-125 Implant Brachytherapy in Japanese Men: Nationwide J-POPS Multi-institutional Prospective Cohort Study

Purpose: To assess, in a nationwide multi-institutional cohort study begun in 2005 and in which 6927 subjects were enrolled by 2010, the urinary and rectal toxicity profiles of subjects who enrolled during the first 2 years, and evaluate the toxicity profiles for permanent seed implantation (PI) and a combination therapy with PI and external beam radiation therapy (EBRT). Methods and Materials: Baseline data for 2339 subjects out of 2354 patients were available for the analyses. Toxicities were evaluated using the National Cancer Institute's Common Terminology Criteria for Adverse Events, and the International Prostate Symptom Scores were recorded prospectively until 36 months after radiation therapy. Results: Grade 2+ acute urinary toxicities developed in 7.36% (172 of 2337) and grade 2+ acute rectal toxicities developed in 1.03% (24 of 2336) of the patients. Grade 2+ late urinary and rectal toxicities developed in 5.75% (133 of 2312) and 1.86% (43 of 2312) of the patients, respectively. A higher incidence of grade 2+ acute urinary toxicity occurred in the PI group than in the EBRT group (8.49% vs 3.66%; P<.01). Acute rectal toxicity outcomes were similar between the treatment groups. The 3-year cumulative incidence rates for grade 2+ late urinary toxicities were 6.04% versus 4.82% for the PI and the EBRT groups, respectively, with no significant differences between the treatment groups. The 3-year cumulative incidence rates for grade 2+ late rectal toxicities were 0.90% versus 5.01% (P<.01) for the PI and the EBRT groups, respectively. The mean of the postimplant International Prostate Symptom Score peaked at 3 months, but it decreased to a range that was within 2 points of the baseline score, which was observed in 1625 subjects (69.47%) at the 1-year follow-up assessment. Conclusions: The acute urinary toxicities observed were acceptable given the frequency and retention, and the late rectal toxicities were more favorable than those of other studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗