Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image Reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

A line-source method for aligning on-board and other pinhole SPECT systems

Purpose: In order to achieve functional and molecular imaging as patients are in position for radiation therapy, a robotic multipinhole SPECT system is being developed. Alignment of the SPECT system—to the linear accelerator (LINAC) coordinate frame and to the coordinate frames of other on-board imaging systems such as cone-beam CT (CBCT)—is essential for target localization and image reconstruction. An alignment method that utilizes line sources and one pinhole projection is proposed and investigated to achieve this goal. Potentially, this method could also be applied to the calibration of the other pinhole SPECT systems.Methods: An alignment model consisting of multiple alignment parameters was developed which maps line sources in three-dimensional (3D) space to their two-dimensional (2D) projections on the SPECT detector. In a computer-simulation study, 3D coordinates of line-sources were defined in a reference room coordinate frame, such as the LINAC coordinate frame. Corresponding 2D line-source projections were generated by computer simulation that included SPECT blurring and noise effects. The Radon transform was utilized to detect angles (α) and offsets (ρ) of the line-source projections. Alignment parameters were then estimated by a nonlinear least squares method, based on the α and ρ values and the alignment model. Alignment performance was evaluated as a function of number of line sources, Radon transform accuracy, finite line-source width, intrinsic camera resolution, Poisson noise, and acquisition geometry. Experimental evaluations were performed using a physical line-source phantom and a pinhole-collimated gamma camera attached to a robot.Results: In computer-simulation studies, when there was no error in determining angles (α) and offsets (ρ) of the measured projections, six alignment parameters (three translational and three rotational) were estimated perfectly using three line sources. When angles (α) and offsets (ρ) were provided by the Radon transform, estimation accuracy was reduced. The estimation error was associated with rounding errors of Radon transform, finite line-source width, Poisson noise, number of line sources, intrinsic camera resolution, and detector acquisition geometry. Statistically, the estimation accuracy was significantly improved by using four line sources rather than three and by thinner line-source projections (obtained by better intrinsic detector resolution). With five line sources, median errors were 0.2 mm for the detector translations, 0.7 mm for the detector radius of rotation, and less than 0.5° for detector rotation, tilt, and twist. In experimental evaluations, average errors relative to a different, independent registration technique were about 1.8 mm for detector translations, 1.1 mm for the detector radius of rotation (ROR), 0.5° and 0.4° for detector rotation and tilt, respectively, and 1.2° for detector twist.Conclusions: Alignment parameters can be estimated using one pinhole projection of line sources. Alignment errors are largely associated with limited accuracy of the Radon transform in determining angles (α) and offsets (ρ) of the line-source projections. This alignment method may be important for multipinhole SPECT, where relative pinhole alignment may vary during rotation. For pinhole and multipinhole SPECT imaging on-board radiation therapy machines, the method could provide alignment of SPECT coordinates with those of CBCT and the LINAC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First-order convex feasibility algorithms for x-ray CT

Purpose: Iterative image reconstruction (IIR) algorithms in computed tomography (CT) are based on algorithms for solving a particular optimization problem. Design of the IIR algorithm, therefore, is aided by knowledge of the solution to the optimization problem on which it is based. Often times, however, it is impractical to achieve accurate solution to the optimization of interest, which complicates design of IIR algorithms. This issue is particularly acute for CT with a limited angular-range scan, which leads to poorly conditioned system matrices and difficult to solve optimization problems. In this paper, we develop IIR algorithms which solve a certain type of optimization called convex feasibility. The convex feasibility approach can provide alternatives to unconstrained optimization approaches and at the same time allow for rapidly convergent algorithms for their solution-thereby facilitating the IIR algorithm design process. Methods: An accelerated version of the Chambolle-Pock (CP) algorithm is adapted to various convex feasibility problems of potential interest to IIR in CT. One of the proposed problems is seen to be equivalent to least-squares minimization, and two other problems provide alternatives to penalized, least-squares minimization. Results: The accelerated CP algorithms are demonstrated on a simulation of circular fan-beam CT with a limited scanning arc of 144 Degree-Sign . The CP algorithms are seen in the empirical results to converge to the solution of their respective convex feasibility problems. Conclusions: Formulation of convex feasibility problems can provide a useful alternative to unconstrained optimization when designing IIR algorithms for CT. The approach is amenable to recent methods for accelerating first-order algorithms which may be particularly useful for CT with limited angular-range scanning. The present paper demonstrates the methodology, and future work will illustrate its utility in actual CT application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent Advancements in Tomographic Gamma Scanning for Non- Destructive Assay - 17321

Canberra Industries has recently designed and built a Tomographic Gamma Scanning (TGS) system for the deployment in a nuclear facility. The TGS technique combines high-resolution gamma spectroscopy with low spatial resolution 3- dimensional image reconstruction to provide increased accuracy over traditional approaches for the assay of non-uniform source distributions in low-to medium-density containers. The TGS system has been optimized to measure 120 liter drums and has the capability to measure containers of various sizes. Canberra has incorporated numerous enhancements and improvements to the latest system in both its hardware and software components. The signal processing chain and data analysis software have been configured to use either an electronic pulser or digital signal processing (DSP) electronics for dead time corrections. In the case of using the DSP electronics, the need to calibrate and maintain a pulser can be eliminated without sacrificing any performance. For the 120 liter container, the TGS system has been calibrated and validated with three different spatial resolutions, using two collimator aperture sizes, measuring 2.54 and 1.27 cm in width. The system has also been supplied and calibrated with a wide, rectangular collimator (25.4 cm W x 10.2 cm H) for scanning containers solely in the vertical axis. The TGS system also has an automated attenuator assembly, which has the capability to use a combination of attenuators to reduce the count rate for high activity samples. An extensive measurement campaign was performed in addition to the calibration verification to evaluate the accuracy of the system using rod sources, point sources, and a variety of matrices and source distributions. Improvements to the evaluation of the total measurement uncertainty based upon these studies have been incorporated into the analysis software package. Finally, the performance of this new TGS system will be demonstrated in the context of Canberra's previous TGS systems, including several 208 liter-based systems and a smaller, 20 liter container TGS system. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dedicated breast CT: radiation dose for circle-plus-line trajectory

Purpose: Dedicated breast CT prototypes used in clinical investigations utilize single circular source trajectory and cone-beam geometry with flat-panel detectors that do not satisfy data-sufficiency conditions and could lead to cone beam artifacts. Hence, this work investigated the glandular dose characteristics of a circle-plus-line trajectory that fulfills data-sufficiency conditions for image reconstruction in dedicated breast CT. Methods: Monte Carlo-based computer simulations were performed using the GEANT4 toolkit and was validated with previously reported normalized glandular dose coefficients for one prototype breast CT system. Upon validation, Monte Carlo simulations were performed to determine the normalized glandular dose coefficients as a function of x-ray source position along the line scan. The source-to-axis of rotation distance and the source-to-detector distance were maintained constant at 65 and 100 cm, respectively, in all simulations. The ratio of the normalized glandular dose coefficient at each source position along the line scan to that for the circular scan, defined as relative normalized glandular dose coefficient (RD{sub g}N), was studied by varying the diameter of the breast at the chest wall, chest-wall to nipple distance, skin thickness, x-ray beam energy, and glandular fraction of the breast. Results: The RD{sub g}N metric when stated as a function of source position along the line scan, relative to the maximum length of line scan needed for data sufficiency, was found to be minimally dependent on breast diameter, chest-wall to nipple distance, skin thickness, glandular fraction, and x-ray photon energy. This observation facilitates easy estimation of the average glandular dose of the line scan. Polynomial fit equations for computing the RD{sub g}N and hence the average glandular dose are provided. Conclusions: For a breast CT system that acquires 300-500 projections over 2{pi} for the circular scan, the addition of a line trajectory with equal source spacing and constant x-ray beam quality (kVp and HVL) and mAs matched to the circular scan, will result in less than 0.18% increase in average glandular dose to the breast per projection along the line scan.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Mobile Automated Tomographic Gamma Scanning System - 13231

Canberra Industries have recently designed and built a new automated Tomographic Gamma Scanning (TGS) system for mobile deployment. The TGS technique combines high-resolution gamma spectroscopy with low spatial resolution 3-dimensional image reconstruction to provide increased accuracy over traditional approaches for the assay of non-uniform source distributions in low-to medium-density, non-heterogeneous matrices. Originally pioneered by R. Estep at Los Alamos National Laboratory (LANL), the TGS method has been further developed and commercialized by Canberra Industries in recent years. The present system advances the state of the art on several fronts: it is designed to be housed in a standard cargo transport container for ease of transport, allowing waste characterization at multiple facilities under the purview of a single operator. Conveyor feed, drum rotator, and detector and collimator positioning mechanisms operated by programmable logic control (PLC) allow automated batch mode operation. The variable geometry settings can accommodate a wide range of waste packaging, including but not limited to standard 220 liter drums, 380 liter overpack drums, and smaller 20 liter cans. A 20 mCi Eu-152 transmission source provides attenuation corrections for drum matrices up to 1 g/cm{sup 3} in TGS mode; the system can be operated in Segmented Gamma Scanning (SGS) mode to measure higher density drums. To support TGS assays at higher densities, the source shield is sufficient to house an alternate Co-60 transmission source of higher activity, up to 250 mCi. An automated shutter and attenuator assembly is provided for operating the system with a dual intensity transmission source. The system's 1500 kg capacity rotator turntable can handle heavy containers such as concrete lined 380 liter overpack drums. Finally, data acquisition utilizes Canberra's Broad Energy Germanium (BEGE) detector and Lynx MCA, with 32 k channels, providing better than 0.1 keV/channel resolution to support both isotopic analysis with the MGA/MGAU software and a wide 3 MeV dynamic range. The calibration and verification of the system is discussed, and quantitative results are presented for a variety of drum types and matrices. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The MicroBooNE Search For Anomalous Electron Neutrino Appearance Using Image Based Data Reconstruction

This thesis presents the MicroBooNE search for the MiniBooNE low energy excess using a fully automated image based data reconstruction scheme. A suite of traditional and deep learning computer vision algorithms are developed for identication of charge current quasi-elastic (CCQE) like muon and electron neutrino interactions using the MicroBooNE detector. Given a model of the MiniBooNE low energy excess as due to an enhancement of electron neutrino type events, this analysis predicts a combined statistical and systematic 3.8 low energy signal in 13:2 1020 POT of MicroBooNE data. When interpreted in the context of ! e 3 + 1 sterile neutrino oscillations a best t point of (m2 41; sin2 2e) = (0:063; 0:794) is found with a 90% condence allowed region consistent with > 0:1 eV2 oscillations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Vision-based inspection of prefabricated components using camera poses: Addressing inherent limitations of image-based 3D reconstruction

Modular construction can lead to additional cost overruns and delays when a defect is found on the construction site and is not easily repairable. Researchers have developed various methods that use image-based 3D reconstruction for quality assessment, but they have inherent limitations, such as inconsistency and dealing with surfaces with reflectivity and limited visual features. Therefore, this paper presents a vision-based quality assessment method using cameras for prefabricated components by addressing these limitations. Specifically, this paper proposes a novel quality inspection method with sub-millimeter accuracy using cameras focused on leveraging camera poses (as opposed to 3D point clouds that are often not consistent in quality) from the image-based 3D reconstruction. The 3D point estimation by computing triangulation was used for achieving accurate measurement. The proposed method is validated using six different variances and two case studies – an aluminum pipe with a reflective surface and a fabricated concrete column. Furthermore, the results demonstrate the accuracy and effectiveness of the proposed method.

42 ENGINEERING↗

The United States Department of Energy and National Institutes of Health Collaboration: Medical Care Advances by Discovery in Radiation Detection

A National Institutes of Health (NIH) and U.S. Department of Energy (DOE) Office of Science virtual workshop on shared general topics was held in July of 2021 and reported on in this publication in January of 2023. Following the inaugural 2021 joint meeting representatives from the DOE Office of Science and NIH met to discuss organizing a second joint workshop that would concentrate on radiation detection to bring together teams from both agencies and their grantee populations to stimulate collaboration and efficiency. To meet this scientific mission within the NIH and DOE radiation detection space, the organizers assembled workshop sessions covering the state–of–the–art in cameras, detectors, and sensors for radiation external and internal (diagnostic and therapeutic) to human, data acquisition and electronics, image reconstruction and processing, and the application of artificial intelligence. NIH and DOE are committed to continuing the process of convening a joint workshop every 12–24 months. This Special Report recaps the findings of this second workshop. Beyond showing only the innovations and areas of success, important gaps in our knowledge were defined and presented. Finally, we summarize by defining four areas of greatest opportunity and need that emerged from the unique, dynamic dialogue the in–person workshop provided the attendees.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Deep Learning Approach for Detection and Localization of Leaf Anomalies

The detection and localization of possible diseases in crops are usually automated by resorting to supervised deep learning approaches. In this work, we tackle these goals with unsupervised models, by applying three different types of autoencoders to a specific open-source dataset of healthy and unhealthy pepper and cherry leaf images. CAE, CVAE and VQ-VAE autoencoders are deployed to screen unlabeled images of such a dataset, and compared in terms of image reconstruction, anomaly removal, detection and localization. The vector-quantized variational architecture turns out to be the best performing one with respect to all these targets.

Calabro', Davide↗

Modeling the tagged-neutron UXO identification technique using the Geant4 toolkit

It is proposed to use 14 MeV neutrons tagged by the associated particle neutron time-of-flight technique (APnTOF) to identify the fillers of unexploded ordnances (UXO) by characterizing their carbon, nitrogen and oxygen contents. To facilitate the design and construction of a prototype system, a preliminary simulation model was developed, using the Geant4 toolkit. This work established the toolkit environment for (a) generating tagged neutrons, (b) their transport and interactions within a sample to induce emission and detection of characteristic gamma-rays, and (c) 2D and 3D-image reconstruction of the interrogated object using the neutron and gamma-ray time-of-flight information. Using the modeling, this article demonstrates the novelty of the tagged-neutron approach for extracting useful signals with high signal-to-background discrimination of an object-of-interest from that of its environment. Simulations indicated that an UXO filled with the RDX explosive, hexogen (C{sub 3}H{sub 6}O{sub 6}N{sub 6}), can be identified to a depth of 20 cm when buried in soil.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of initial and steady-state sliding behavior of a nearly-frictionless carbon film by imaging 2- and 3-D TOF-SIMS.

Using imaging time-of-flight secondary ion mass spectrometry (TOF-SIMS), we investigated the initial and steady-state sliding behavior of a nearly frictionless carbon (NFC) film. Specifically, TOF-SIMS images (both 2-D and 3-D) of these surfaces were constructed to highlight the spatial distributions of ionized and molecular species that were present on as-received and friction-tested NFC surfaces and as a function of depth. As a complementary technique, we used X-ray photoelectron spectroscopy (XPS) to gain further insight into the chemical nature of the sliding surfaces. The NFC films were produced on Si wafers and steel substrates in a gas discharge plasma that consisted of 25 vol.% methane and 75 vol.% hydrogen using a plasma-enhanced chemical vapor deposition (PECVD) system. They were then subjected to sliding friction and wear experiments in a pin-on-disk machine under 5- and 10-N loads and at sliding velocities of 0.2-0.5 m/s in dry nitrogen. The initial friction coefficients of the NFC films were in the range of 0.05-0.1, but decreased rapidly to values less than 0.01 at steady state. Positive and negative TOF-SIMS spectra and 2- and 3-D images reconstructed from selected masses revealed that the elemental distribution of certain chemical species differs substantially between undisturbed and tribo-tested areas of the NFC films. Specifically, the tribo-tested areas are essentially made up of carbon and hydrogen, while undisturbed or as-received areas are covered by a layer that is rich in oxygen and other species. These findings correlate well with the initial and steady-state friction coefficients of these films and help further explain their superlubricity in inert test environments.

03 NATURAL GAS↗

The impact of positron range on PET resolution, evaluated with phantoms and PHITS Monte Carlo simulations for conventional and non-conventional radionuclides

The increasing interest and availability of non-standard positron-emitting radionuclides has heightened the relevance of radionuclide choice in the development and optimization of new positron emission tomography (PET) imaging procedures, both in preclinical research and clinical practice. Differences in achievable resolution arising from positron range can largely influence application suitability of each radionuclide, especially in small-ring preclinical PET where system blurring factors due to annihilation photon acollinearity and detector geometry are less significant. Here, some resolution degradation can be mitigated with appropriate range corrections implemented during image reconstruction, the quality of which is contingent on an accurate characterization of positron range.

43 PARTICLE ACCELERATORS↗

Comparison of maximal Rubidium-82 activities for myocardial blood flow quantification between digital and conventional PET systems

Background: PET-based myocardial blood flow (MBF) quantification can be inaccurate when using high tracer activities. Our aim was to derive the maximal Rubidium-82 activity for MBF assessment using a new digital PET system and compare the results with conventional analog systems. Methods: 1.8 GBq Rubidium-82 was injected into the cardiac insert of an anthropomorphic torso phantom. Data were acquired for 10 min using an Ingenuity TF (Philips Healthcare), Discovery 690 (D690, GE Healthcare), and digital PET prototype system (Philips Healthcare). The dynamic ranges, defined as the maximal measured activity in the reconstructed images deviating < 10% from the true present activity, were determined in all scans. Results: The dynamic ranges were 312 MBq for Ingenuity TF, 650 MBq for D690, and 654 MBq for digital PET prototype. Conclusions: The maximal Rb-82 activity for MBF assessment using digital PET prototype is higher than that for its analog counterpart (Ingenuity TF), but seems comparable to the D690.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Topological analysis of X-ray CT data for the recognition and trending of subtle changes in microstructure under material aging

X-ray computed tomography (CT) is an established non-destructive tool for 3D imaging of multiphasic composites. Numerous applications of X-ray CT in medical diagnosis and materials characterization have been reported, many involving field-specific innovations in the imaging technology itself. Yet, quantitative summarization to link image features to properties of interest has been rare. Here we address this issue by employing state-of-the-art technics in scalar field topology for the summarization of X-ray CT images of an example biphasic system. By varying processing-parameters we create different microstructures, evolve them through accelerated thermal aging, CT-image them pre- and post-aged, and demonstrate the ability of our image summarization method to systematically track process- and age-related changes, which can often be very subtle. A novel aspect of the algorithm involves recognition over multiple resolution levels, which provides deeper insight into the pattern relationship between grain-like features and their neighbors. The method is general, adaptable to diverse image reconstruction methods and materials systems, and particularly useful in applications where practical constraints on the sample-size limits the reliable use of more complex models, e.g., convolutional neural networks.

36 MATERIALS SCIENCE↗

Efficient distributed continual learning for steering experiments in real-time

Deep learning has emerged as a powerful method for extracting valuable information from large volumes of data. However, when new training data arrives continuously (i.e., is not fully available from the beginning), incremental training suffers from catastrophic forgetting (i.e., new patterns are reinforced at the expense of previously acquired knowledge). Training from scratch each time new training data becomes available would result in extremely long training times and massive data accumulation. Rehearsal-based continual learning has shown promise for addressing the catastrophic forgetting challenge, but research to date has not addressed performance and scalability. To fill this gap, we propose an approach based on a distributed rehearsal buffer that efficiently complements data-parallel training on multiple GPUs to achieve high accuracy, short runtime, and scalability. It leverages a set of buffers (local to each GPU) and uses several asynchronous techniques for updating these local buffers in an embarrassingly parallel fashion, all while handling the communication overheads necessary to augment input minibatches using unbiased, global sampling. We further propose a generalization of rehearsal buffers to support both classification and generative learning tasks, as well as more advanced rehearsal strategies (notably Dark Experience Replay, leveraging knowledge distillation). We illustrate this approach with a real-life HPC streaming application from the domain of ptychographic image reconstruction. Furthermore, we run extensive experiments on up to 128 GPUs of the ThetaGPU supercomputer to compare our approach with baselines representative of training-from-scratch (the upper bound in terms of accuracy) and incremental training (the lower bound). Results show that rehearsal-based continual learning achieves a top-5 validation accuracy close to the upper bound, while simultaneously exhibiting a runtime close to the lower bound.

Asynchronous data management↗

Cryoelectron Microscopy Structure of Purified gamma-Secretase at 12 angstrom Resolution

{gamma}-Secretase, an integral membrane protein complex, catalyzes the intramembrane cleavage of the {beta}-amyloid precursor protein (APP) during the neuronal production of the amyloid {beta}-peptide. As such, the protease has emerged as a key target for developing agents to treat and prevent Alzheimer's disease. Existing biochemical studies conflict on the oligomeric assembly state of the protease complex, and its detailed structure is not known. Here, we report that purified active human {gamma}-secretase in digitonin has a total molecular mass of {approx} 230 kDa when measured by scanning transmission electron microscopy. This result supports a complex that is monomeric for each of the four component proteins. We further report the three-dimensional structure of the {gamma}-secretase complex at 12 {angstrom} resolution as obtained by cryoelectron microscopy and single-particle image reconstruction. The structure reveals several domains on the extracellular side, three solvent-accessible low-density cavities, and a potential substrate-binding surface groove in the transmembrane region of the complex.

59 BASIC BIOLOGICAL SCIENCES↗

IrSr{sub 2}TbCu{sub 2}O{sub 8}, a high-pressure metamagnetic cuprate: Structure, microstructure and properties

The synthesis, structure and microstructure of the IrSr{sub 2}TbCu{sub 2}O{sub 8} cuprate showing metamagnetic properties are described. The sample was prepared at high temperatures and pressures up to 9.2 GPa. The structure is tetragonal, showing a 1212 type structure, that derives from the classical YBaCuO superconductor structure, replacing the tetracoordinated square planar copper [Cu-O{sub 4}] in the 'chains' by octahedral [Ir-O{sub 6}] groups that form a perovskite-like layer in the basal plane of the unit cell. A 'simple' cell, {approx}a{sub p}xa{sub p}x3a{sub p}, where a{sub p} is the basic perovskite unit cell parameter (a{sub p}{approx}3.8 A), is supported by X-ray powder diffraction (XRD) and a so-called 'diagonal' one, {approx}{radical}2a{sub p}x{radical}2a{sub p}x3a{sub p}, by SAED; a microdomain texture of latter cell and a series of very interesting extended defects have been observed by HREM. Magnetic susceptibility measurements show a magnetic transition, T{sub N}{approx}6 K, with negative Weiss temperature, that indicates antiferromagnetic interactions among the Tb moments. The magnetic structure has been determined by neutron diffraction. A detailed magnetic study has revealed a metamagnetic behavior, something not previously observed in this type of cuprates. Specific heat and resistivity measurements have also been performed to characterize the transition. - Graphical abstract: Reconstructed image from the SAED of the long c tetragonal axis (3a{sub p}) of a IrSr{sub 2}TbCu{sub 2}O{sub 8} crystal. A unit cell picture is included for comparison. Display Omitted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimization and evaluation of metal injection molding by using X-ray tomography

6061 aluminum alloy and 316L stainless steel green bodies were obtained by using different injection parameters (injection pressure, speed and temperature). After injection process, the green bodies were scanned by X-ray tomography. The projection and reconstruction images show the different kinds of defects obtained by the improper injection parameters. Then, 3D rendering of the Al alloy green bodies was used to demonstrate the spatial morphology characteristics of the serious defects. Based on the scanned and calculated results, it is convenient to obtain the proper injection parameters for the Al alloy. Then, reasons of the defect formation were discussed. During mold filling, the serious defects mainly formed in the case of low injection temperature and high injection speed. According to the gray value distribution of projection image, a threshold gray value was obtained to evaluate whether the quality of green body can meet the desired standard. The proper injection parameters of 316L stainless steel can be obtained efficiently by using the method of analyzing the Al alloy injection. - Highlights: • Different types of defects in green bodies were scanned by using X-ray tomography. • Reasons of the defect formation were discussed. • Optimization of the injection parameters can be simplified greatly by the way of X-ray tomography. • Evaluation standard of the injection process can be obtained by using the gray value distribution of projection image.

36 MATERIALS SCIENCE↗