Search NASA⌕ Search

SEARCH · Search NASA

Results for “Insertion device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

RHETT/EPDM Flight Hollow Cathode

Under the sponsorship of the BMDO Russian Hall Electric Thruster Technology program two xenon hollow cathodes, a flight unit and a flight spare were fabricated, acceptance tested and delivered to the Naval Research Laboratory for use on the Electric Propulsion Demonstration Module. These hollow cathodes, based on the International Space Station plasma contactor design, were fabricated at the NASA Lewis Research Center for use with a D-55 anode layer thruster in the first on-orbit operational application of this technology. The 2.2 Ampere nominal emission current of this device was obtained with a xenon flow rate of 0.6 mg/s. Ignition of the cathode discharge was accomplished through preheating the active electron emitter with a resistive heating element before application of a 650 volt ignition pulse between the emitter and an external starting electrode. The successful acceptance testing of the Electric Propulsion Demonstration Module utilizing these cathodes demonstrated the suitability of cathodes based on barium impregnated inserts in an enclosed keeper configuration for use with Hall thruster propulsion systems.

Manzella, David↗

Simulation analysis of graphene contacted perovskite solar cells using SCAPS-1D

To understand what cause the low performance in a perovskite cell with graphene back contact, we have performed simulations of device characteristics using SCAPs-1D simulation platform. The impact of increasing defect concentration at the interface of perovskite/graphene (RGO) and also graphene thickness on the current density, voltage, fill factor, and conversion efficiency of the cell was investigated. We converted the graphene nanostructure to a planar p-type layer at the top side of the cell as a hole transporting layer in order to enable to insert it into the SCAPS simulation platform. The simulation analysis were compared to the experimental data reported in literature. The voltage and fill factor of the simulation and experiments are almost the same but the current density is showing to be higher in simulation analysis which reminds a imperfect thickness and absorption by the graphene layer. Graphene was also compared to Spiro-MeOTAD showing to be a promising materials to act as both hole transporting layer and back contact. The experimental process could be improved by looking at our results as a method to fabricate a high performance cell with graphene electrode. It is shown that such a hybrid structure suffers from imperfect interface at graphene and perovskite junction where a high concentration of trap density impedes the carrier collection.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Organic integrated circuits for information storage based on ambipolar polymers and charge injection engineering

Ambipolar semiconducting polymers, characterized by both high electron (μ{sub e}) and hole (μ{sub h}) mobility, offer the advantage of realizing complex complementary electronic circuits with a single semiconducting layer, deposited by simple coating techniques. However, to achieve complementarity, one of the two conduction paths in transistors has to be suppressed, resulting in unipolar devices. Here, we adopt charge injection engineering through a specific interlayer in order to tune injection into frontier energy orbitals of a high mobility donor-acceptor co-polymer. Starting from field-effect transistors with Au contacts, showing a p-type unbalanced behaviour with μ{sub h} = 0.29 cm{sup 2}/V s and μ{sub e} = 0.001 cm{sup 2}/V s, through the insertion of a caesium salt interlayer with optimized thickness, we obtain an n-type unbalanced transistor with μ{sub e} = 0.12 cm{sup 2}/V s and μ{sub h} = 8 × 10{sup −4} cm{sup 2}/V s. We applied this result to the development of the basic pass-transistor logic building blocks such as inverters, with high gain and good noise margin, and transmission-gates. In addition, we developed and characterized information storage circuits like D-Latches and D-Flip-Flops consisting of 16 transistors, demonstrating both their static and dynamic performances and thus the suitability of this technology for more complex circuits such as display addressing logic.

36 MATERIALS SCIENCE↗

Evaluation of the peripheral dose in stereotactic radiotherapy and radiosurgery treatments

Purpose: The main purpose of this work was to compare peripheral doses absorbed during stereotactic treatment of a brain lesion delivered using different devices. These data were used to estimate the risk of stochastic effects. Methods: Treatment plans were created for an anthropomorphic phantom and delivered using a LINAC with stereotactic cones and a multileaf collimator, a CyberKnife system (before and after a supplemental shielding was applied), a TomoTherapy system, and a Gamma Knife unit. For each treatment, 5 Gy were prescribed to the target. Measurements were performed with thermoluminescent dosimeters inserted roughly in the position of the thyroid, sternum, upper lung, lower lung, and gonads. Results: Mean doses ranged from of 4.1 (Gamma Knife) to 62.8 mGy (LINAC with cones) in the thyroid, from 2.3 (TomoTherapy) to 30 mGy (preshielding CyberKnife) in the sternum, from 1.7 (TomoTherapy) to 20 mGy (preshielding CyberKnife) in the upper part of the lungs, from 0.98 (Gamma Knife) to 15 mGy (preshielding CyberKnife) in the lower part of the lungs, and between 0.3 (Gamma Knife) and 10 mGy (preshielding CyberKnife) in the gonads. Conclusions: The peripheral dose absorbed in the sites of interest with a 5 Gy fraction is low. Although the risk of adverse side effects calculated for 20 Gy delivered in 5 Gy fractions is negligible, in the interest of optimum patient radioprotection, further studies are needed to determine the weight of each contributor to the peripheral dose.

60 APPLIED LIFE SCIENCES↗

Verifiable process monitoring through enhanced data authentication.

To ensure the peaceful intent for production and processing of nuclear fuel, verifiable process monitoring of the fuel production cycle is required. As part of a U.S. Department of Energy (DOE)-EURATOM collaboration in the field of international nuclear safeguards, the DOE Sandia National Laboratories (SNL), the European Commission Joint Research Centre (JRC) and Directorate General-Energy (DG-ENER) developed and demonstrated a new concept in process monitoring, enabling the use of operator process information by branching a second, authenticated data stream to the Safeguards inspectorate. This information would be complementary to independent safeguards data, improving the understanding of the plant's operation. The concept is called the Enhanced Data Authentication System (EDAS). EDAS transparently captures, authenticates, and encrypts communication data that is transmitted between operator control computers and connected analytical equipment utilized in nuclear processes controls. The intent is to capture information as close to the sensor point as possible to assure the highest possible confidence in the branched data. Data must be collected transparently by the EDAS: Operator processes should not be altered or disrupted by the insertion of the EDAS as a monitoring system for safeguards. EDAS employs public key authentication providing 'jointly verifiable' data and private key encryption for confidentiality. Timestamps and data source are also added to the collected data for analysis. The core of the system hardware is in a security enclosure with both active and passive tamper indication. Further, the system has the ability to monitor seals or other security devices in close proximity. This paper will discuss the EDAS concept, recent technical developments, intended application philosophy and the planned future progression of this system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-E-T-315: Dosimetric Effects of Couch Top Shift On VMAT Delivery in Absence of Indexing

Purpose: To investigate dosimetric effects of couch top shift for volumetric-modulated arc therapy (VMAT) in absence of indexing of immobilization devices. Methods: A total of twelve VMAT treatment plans were selected from three regions (lung, abdomen, and pelvis) to account for the variation of the patient position relative to the couch top. The treatment plans were generated using the Varian Eclipse system. A pinpoint ionization chamber (PTW TN31014) was placed at the center of 16-cm solid water phantom and the dose was delivered using the Varian TrueBeam STx with BrainLAB ExacTrac couch top. To simulate the day-to-day variation of the patient position relative to couch top, the couch top was laterally shifted up to 50 mm, with an increment of 5 mm from 0 to 20 mm; and of 10 mm afterwards, and the phantom was moved back to 0 cm shift for measurement. The dose was also delivered using a Varian tennis racket grid insert at 0 cm shift to simulate the absence of couch top. The treatment plans were delivered with 6, 10, and 15 MV photons using the same leaf sequencing to investigate the energy dependence of couch top shift. The dose difference was normalized to 0 cm shift for the regular couch top for comparison. Results: The percent difference of dose was found to increase with lateral shift for all energies; however, the average differences were close to 0% and the maximum difference was within 1% along the lateral shifts. The differences with the absence of couch top were 2.2±0.5% (6MV), 1.7±0.3% (10MV), and 1.6±0.2% (15MV), respectively. Conclusion: The inclusion of couch top is recommended in treatment planning to minimize the dosimetric uncertainty between calculated and delivered dose even in absence of indexing of immobilization devices in VMAT delivery.

60 APPLIED LIFE SCIENCES↗

The SIRAD irradiation facility at LNL

SIRAD is the irradiation facility at the Tandem XTU accelerator of the INFN National Laboratory of Legnaro (Padova, Italy) dedicated to study radiation effects, both comulative and Single Event, on silicon detectors and microelectronic devices and systems. SIRAD is routinely used by various research groups involved in the development of semiconductor detectors and electronics to be used in radiation hostile environments as experiments at high-energy/high luminosity accelerators or in space, or interested to study the basic radiation damage mechanisms. Single Events Effects (SEE) studies with micrometric resolution can be performed at SIRAD thanks to an Ion Electron Emission Microscope (IEEM) inserted at the end of the beam line. Here we describe the SIRAD facility including the available and future beam characteristics, and the IEEM performances as well as the scientific and technological solutions which have been implemented for its construction.

43 PARTICLE ACCELERATORS↗

A Nonfullerene Acceptor with Alkylthio‐ and Dimethoxy‐Thiophene‐Groups Yielding High‐Performance Ternary Organic Solar Cells

Herein, an A–D–A‐type nonfullerene acceptor (named IDTS‐4F) with an alkyl thiophenyl side chain and dimethoxy thiophene bridging unit is reported. The use of an alkyl thiophenyl group is important, as the insertion of sulfur atoms can slightly downshift the highest occupied molecular orbital (HOMO) level of the molecule and allows IDTS‐4F to match with state‐of‐the‐art donor polymer PM6 (or PM7). Compared with conventional nonfullerene acceptors, IT‐4F, the IDTS‐4F molecule, has a smaller optical bandgap and higher lowest unoccupied molecular orbital (LUMO) level, which are beneficial to increase the V oc and J sc of the devices. Nonfullerene organic solar cell devices are fabricated using IDTS‐4F. Although the binary device based on IDTS‐4F exhibits a lower fill factor (FF, 70%), the ternary device by incorporating 0.2 of IDTS‐4F and 0.8 of IT‐4F (with PM6 as the donor polymer) can simultaneously achieve a higher V oc and J sc , while maintaining the high FF (77%) of IT‐4F based system. Morphology characterizations indicate the formation of homogeneous film morphology, the large increase in phase purity and crystallinity, and the reduction in domain size upon addition of crystalline IDTS‐4F, while the electron/hole mobilities and recombination losses of the IT‐4F system are both maintained.

Zeng, Anping↗

SU-E-T-150: Brachytherapy QA Employing a High Resolution Liquid Filled Ionisation Chamber Array: Initial Experience and Limitations

Purpose: Verifying a complex 3D brachytherapy dose distribution by measurement is non-trivial. Ideally a photon detector array should be independent of energy and angle, have high spatial resolution and be robust for routine clinical use. Methods: An iridium-192 source was used. A PMMA jig was constructed comprising an outer slab and a central insert with eight milled channels for 1.33mm (outer diameter) steel needles, see figure. All calculations were performed using an empty CT study reconstructing eight virtual needles (QA-CT), using the v2 source model (Elekta AG, Sweden). A high resolution liquid filled ionisation chamber array SRS1000, together with Verisoft software v6.0 (PTW Freiburg, Germany), was used to perform measurements of plans of increasing complexity to evaluate its suitability for device- and patient-specific QA. The dimension of backscatter material was investigated. The patient plan dwell time distribution was entered manually into the QA-CT and the dose distribution was calculated. Results: Our measurements indicate that the array is independent of energy and angle. The resulting measured dose values are linearly interpolated to 2025 values. Shifts of 1mm of the entire needle are readily detectable. Individual dwell position shifts (2.5mm) are also readily measurable. Moreover a dwell time increase of 1 second both in the edge and central region are detectable. Conclusion: The high resolution SRS1000 array is a powerful instrument for brachytherapy QA enabling 977 simultaneous measurements to be performed. Our measurements suggest 60mm of RW3 backscatter material upstream and downstream are sufficient. Local percentage difference analysis is useful for device based QA, normalized relative percentage difference is arguably better for patient specific QA. Automated transfer of patient plan dwell time distribution to the QA plan is required to enable a comprehensive patient QA study to be performed. Moreover the described measurement technique can be used for commissioning new brachytherapy applicators.

60 APPLIED LIFE SCIENCES↗

Multiplexable high-temperature stable and low-loss intrinsic Fabry-Perot in-fiber sensors through nanograting engineering

This paper presents a method of using femtosecond laser inscribed nanograting as low-loss– and high-temperature–stable in-fiber reflectors. By introducing a pair of nanograting inside the core of a single-mode optical fiber, an intrinsic Fabry-Perot interferometer can be created for high-temperature sensing applications. The morphology of the nanograting inscribed in fiber cores was engineered by tuning the fabrication conditions to achieve a high fringe visibility of 0.49 and low insertion loss of 0.002 dB per sensor. Using a white light interferometry demodulation algorithm, we demonstrate the temperature sensitivity, cross-talk, and spatial multiplexability of sensor arrays. Both the sensor performance and stability were studied from room temperature to 1000°C with cyclic heating and cooling. Our results demonstrate a femtosecond direct laser writing technique capable of producing highly multiplexable in-fiber intrinsic Fabry-Perot interferometer sensor devices with high fringe contrast, high sensitivity, and low-loss for application in harsh environmental conditions.

Wang, Mohan (ORCID:0000000166784993)↗

Implementation of Adaptive Digital Controllers on Programmable Logic Devices

Much has been made of the capabilities of Field Programmable Gate Arrays (FPGA's) in the hardware implementation of fast digital signal processing functions. Such capability also makes an FPGA a suitable platform for the digital implementation of closed loop controllers. Other researchers have implemented a variety of closed-loop digital controllers on FPGA's. Some of these controllers include the widely used Proportional-Integral-Derivative (PID) controller, state space controllers, neural network and fuzzy logic based controllers. There are myriad advantages to utilizing an FPGA for discrete-time control functions which include the capability for reconfiguration when SRAM- based FPGA's are employed, fast parallel implementation of multiple control loops and implementations that can meet space level radiation tolerance requirements in a compact form-factor. Generally, a software implementation on a Digital Signal Processor (DSP) device or microcontroller is used to implement digital controllers. At Marshall Space Flight Center, the Control Electronics Group has been studying adaptive discrete-time control of motor driven actuator systems using DSP devices. While small form factor, commercial DSP devices are now available with event capture, data conversion, Pulse Width Modulated (PWM) outputs and communication peripherals, these devices are not currently available in designs and packages which meet space level radiation requirements. In general, very few DSP devices are produced that are designed to meet any level of radiation tolerance or hardness. An alternative is required for compact implementation of such functionality to withstand the harsh environment encountered on spacemap. The goal of this effort is to create a fully digital, flight ready controller design that utilizes an FPGA for implementation of signal conditioning for control feedback signals, generation of commands to the controlled system, and hardware insertion of adaptive-control algorithm approaches. Radiation tolerant FPGA's are a feasible option for reaching this goal.

Gwaltney, David A.↗

Human Flight to Lunar and Beyond - Re-Learning Operations Paradigms

For the first time since the Apollo era, NASA is planning on sending astronauts on flights beyond Low-Earth Orbit (LEO). The Human Space Flight (HSF) program started with a successful initial flight in Earth orbit, in December 2014. The program will continue with two Exploration Missions (EM) to Lunar orbit: EM-1 will be unmanned and EM-2, carrying astronauts, will follow. NASA established a multi-center team to address the communications, and related navigation, needs. This paper will focus on the lessons learned in the team, planning for the missions' parts that are beyond Earth orbit. Many of these lessons had to be re-learned, as the HSF program after operated for many years in Earth orbit. Fortunately, the experience base from tracking robotic missions in deep space by the Deep Space Network (DSN) and close interaction with the HSF community to understand the unique needs (e.g. 2-way voice) resulted in a ConOps that leverages of both the deep space robotic and the Human LEO experiences. Several examples will be used to highlight the unique operational needs for HSF missions beyond Earth Orbit, including: - Navigation. At LEO, HSF missions can rely on Global Positioning System (GPS) devices for orbit determination. For Lunar-and-beyond HSF missions, techniques such as precision 2-way and 3-way Doppler and ranging, Delta-Difference-of-range, and eventually on-board navigation will be used. - Impact of latency - the delay associated with Round-Trip-Light-Time (RTLT). Imagine trying to have a 2-way discussion (audio or video) with an astronaut, with a 2-3 sec delay inserted (for Lunar distances) or 20 minutes delay (for Mars distances). - Balanced communications link. For robotic missions, there has been a heavy emphasis on the downlink data rates, bringing back science data from the instruments on-board the spacecraft. Uplink data rates were of secondary importance, used to send commands to the spacecraft. The ratio of downlink-to-uplink data rates was often 10:1 or more. For HSF, rates for uplink and downlink, at least for high-quality video, need to be similar.

Kenny, Ted↗

Monte Carlo model for a prototype CT-compatible, anatomically adaptive, shielded intracavitary brachytherapy applicator for the treatment of cervical cancer

Purpose: Current, clinically applicable intracavitary brachytherapy applicators that utilize shielded ovoids contain a pair of tungsten-alloy shields which serve to reduce dose delivered to the rectum and bladder during source afterloading. After applicator insertion, these fixed shields are not necessarily positioned to provide optimal shielding of these critical structures due to variations in patient anatomies. The authors present a dosimetric evaluation of a novel prototype intracavitary brachytherapy ovoid [anatomically adaptive applicator (A{sup 3})], featuring a single shield whose position can be adjusted with two degrees of freedom: Rotation about and translation along the long axis of the ovoid. Methods: The dosimetry of the device for a HDR {sup 192}Ir was characterized using radiochromic film measurements for various shield orientations. A MCNPX Monte Carlo model was developed of the prototype ovoid and integrated with a previously validated model of a v2 mHDR {sup 192}Ir source (Nucletron Co.). The model was validated for three distinct shield orientations using film measurements. Results: For the most complex case, 91% of the absolute simulated and measured dose points agreed within 2% or 2 mm and 96% agreed within 10% or 2 mm. Conclusions: Validation of the Monte Carlo model facilitates future investigations into any dosimetric advantages the use of the A{sup 3} may have over the current state of art with respect to optimization and customization of dose delivery as a function of patient anatomical geometries.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Madison plasma dynamo experiment: A facility for studying laboratory plasma astrophysics

The Madison plasma dynamo experiment (MPDX) is a novel, versatile, basic plasma research device designed to investigate flow driven magnetohydrodynamic instabilities and other high-β phenomena with astrophysically relevant parameters. A 3 m diameter vacuum vessel is lined with 36 rings of alternately oriented 4000 G samarium cobalt magnets, which create an axisymmetric multicusp that contains ∼14 m3of nearly magnetic field free plasma that is well confined and highly ionized (>50%). At present, 8 lanthanum hexaboride (LaB6) cathodes and 10 molybdenum anodes are inserted into the vessel and biased up to 500 V, drawing 40 A each cathode, ionizing a low pressure Ar or He fill gas and heating it. Up to 100 kW of electron cyclotron heating power is planned for additional electron heating. The LaB6cathodes are positioned in the magnetized edge to drive toroidal rotation through J × B torques that propagate into the unmagnetized core plasma. Dynamo studies on MPDX require a high magnetic Reynolds number Rm > 1000, and an adjustable fluid Reynolds number 10 1). Initial results from MPDX are presented along with a 0-dimensional power and particle balance model to predict the viscosity and resistivity to achieve dynamo action.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a Gas-Fed Pulse Detonation Research Engine

In response to the growing need for empirical data on pulse detonation engine performance and operation, NASA Marshall Space Flight Center has developed and placed into operation a low-cost gas-fed pulse detonation research engine. The guiding design strategy was to achieve a simple and flexible research apparatus, which was inexpensive to build and operate. As such, the engine was designed to operate as a heat sink device, and testing was limited to burst-mode operation with run durations of a few seconds. Wherever possible, maximum use was made of standard off-the-shelf industrial or automotive components. The 5-cm diameter primary tube is about 90-cm long and has been outfitted with a multitude of sensor and optical ports. The primary tube is fed by a coaxial injector through an initiator tube, which is inserted directly into the injector head face. Four auxiliary coaxial injectors are also integrated into the injector head assembly. All propellant flow is controlled with industrial solenoid valves. An automotive electronic ignition system was adapted for use, and spark plugs are mounted in both tubes so that a variety of ignition schemes can be examined. A microprocessor-based fiber-optic engine control system was developed to provide precise control over valve and ignition timing. Initial shakedown testing with hydrogen/oxygen mixtures verified the need for Schelkin spirals in both the initiator and primary tubes to ensure rapid development of the detonation wave. Measured pressure wave time-of-flight indicated detonation velocities of 2.4 km/sec and 2.2 km/sec in the initiator and primary tubes, respectively. These values implied a fuel-lean mixture corresponding to an H2 volume fraction near 0.5. The axial distribution for the detonation velocity was found to be essentially constant along the primary tube. Time-resolved thrust profiles were also acquired for both underfilled and overfilled tube conditions. These profiles are consistent with previous time-resolved measurements on single-cycle tubes where the thrust is found to peak as the detonation wave exits the tube, and decay as the tube blows down.

Litchford, Ron J.↗

Life Cycle Testing of Ba(x)Sr(1-x)TiO3 Ferroelectric Thin Films in a Tunable Microwave Device

Thin film ferroelectrics are being studied as candidates for novel tunable microwave components such as tunable filters, tunable oscillators, and phase shifters for applications in phased array antennas. Much work has been done optimizing the ferroelectric material and in producing proof-of-concepts of these components. However, little attention has been given to their reliability. In this study we present our results on the reliability of high quality K-band phase shifters made of Ba(sub x)Sr(sub 1-x)TiO3 (BSTO) ferroelectric thin films (0.5 to 0.75 micrometers thick) on MgO and LAO. The phase shift and insertion loss were measured at 300 K over 104 operation cycles within a 0 to 400 V dc bias range (0 to 40 V/micrometer) at 15, 18, and 22 GHz. Results for these phase shifters indicate that in general there were no appreciable changes in phase shift after 4x10(exp 4) cycles, suggesting that these phase shifters are robust enough to sustain optimal performance under the operating mode typical of fast tracking phased arrays.

Miranda, Felix A.↗

First-Principles Assessment of ZnTe and CdSe as Prospective Tunnel Barriers at the InAs/Al Interface

Majorana zero modes are predicted to emerge in semiconductor/ superconductor interfaces, such as InAs/Al. Majorana modes could be utilized for fault tolerant topological qubits. However, their realization is hindered by materials challenges. The coupling between the superconductor and the semiconductor may be too strong for Majorana modes to emerge, due to effective doping of the semiconductor by the metallic contact. This could be mediated by adding a tunnel barrier of controlled thickness. We use density functional theory (DFT) with Hubbard U corrections, whose values are machine-learned via Bayesian optimization (BO), to assess ZnTe and CdSe as prospective tunnel barriers for the InAs/Al interface. The results of DFT +U(BO) for ZnTe are validated by comparison to angle resolved photoemission spectroscopy (ARPES). We then study bilayer interfaces of the three semiconductors with each other and with Al, as well as trilayer interfaces with a varying number of ZnTe or CdSe layers inserted between InAs and Al. We find that 16 atomic layers of either material completely insulate the InAs from metal induced gap states (MIGS). However, ZnTe and CdSe differ significantly in their band alignment, such that ZnTe forms an effective barrier for electrons, whereas CdSe forms a barrier for holes. Because of Fermi level pinning in the conduction band at the interface, only electron transport is relevant for InAs-based Majorana devices. Therefore, ZnTe is the better choice. Based on the results of our simulations, we suggest conducting experiments with ZnTe barriers in the thickness range of 6–18 atomic layers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Schottky contacts to N-polar GaN with SiN interlayer for elevated temperature operation

In this Letter, we unveil the high-temperature limits of N-polar GaN Schottky contacts enhanced by a low-pressure chemical vapor deposited (LPCVD) SiN interlayer. Compared to conventional Schottky diodes, the insertion of a 5 nm SiN lossy dielectric interlayer in-between Ni and N-polar GaN increases the turn-on voltage (V ON ) from 0.4 to 0.9 V and the barrier height ($\phi_B$) from 0.4 to 0.8 eV. This modification also reduces the leakage current at zero bias significantly: at room temperature, the leakage current in the conventional Schottky diode is >103 larger than that observed in the device with the SiN interlayer, while at 200 °C, this ratio increases to 105. Thus, the rectification ratio (ION/IOFF) at ±1.5 V reduces to less than one at 250 °C for the conventional Schottky diode, whereas for SiN-coated diodes, rectification continues until 500 °C. The I–V characteristics of the diode with an SiN interlayer can be recovered after exposure to 400 °C or lower. Contact degradation occurs at 500 °C, although devices are not destroyed yet. Here, we report N-polar GaN Schottky contact operation up to 500 °C using an LPCVD SiN interlayer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗