Search NASA⌕ Search

SEARCH · Search NASA

Results for “MONOCHROMATIC RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

A search for anisotropy in the cosmic microwave radiation at medium angular scales

The results are reported from a search for anisotropy in the cosmic microwave radiation (CMR) at angular scales of 0.5 to 5 deg. No temperature fluctuations are detected, and limits are placed on intrinsic CMR anisotropy. These limits are expressed in terms of two models which describe the temperature fluctuations. For models specified by a Gaussian-shaped correlation function, the fluctuation amplitude is found to be 1.1 x 10 to the -4th or less at 1.1 deg; for models with monochromatic fluctuations it is 7.5 x 10 to the -5th or less at 1.7 deg. These limits satisfy the likelihood ratio test at the 95 percent confidence level. The implications of the results for large-scale structure information scenarios are discussed.

Timbie, Peter T.↗

Lyman-Alpha Aurora

The existence of intense and variable H Ly a emission from Uranus is demonstrated utilizing the monochromatic imaging capabilities of the International Ultraviolet Explorer satellite. A series of 14 observations, using the IUE short wavelength spectrograph in low dispersion and covering the period from 3 March 1982 through 2 September 1983, shows the disk averaged Ly a brightness of Uranus to vary between 690 and 2230 Rayleighs. Model calculations indicates that 400 R of this emission can be attributed to resonant scattering of solar Ly a radiation. An upper limit of 100 R is obtained for the Raman scattering of solar Ly a by H2 (1280 A). This implies that 300 R is contributed to the planetary Ly a emission by Rayleigh scattering. In addition to being unexpectedly strong, the Uranian Ly a emission has been observed to vary by a factor of two in one 24 hr period and by about 50% in one 5 hr period.

Durrance, S. T.↗

Convective Generation of Cirrus Near the Tropopause

The July 2004 CRYSTAL-FACE field program, based from Key West, Florida, showed that long-lived thin tropopause cirrus (TTC) layers were common above thunderstorm anvils. This paper investigates the origins of these cloud using airborne measurements. The horizontal dimensions of the TTC were nearly identical to the convectively formed anvil beneath. However, the TTC did not appear to have originated from convective detrainment. Rather it appears to have formed in stably stratified air derived from high altitudes near the tropopause. The TTC was separated from the anvil by approx. 1 km, it lacked precipitation particles, and it was strongly depleted in HDO. Nonetheless, compared to surrounding clear air near the tropopause, the TTC was enriched in moisture and trace gases in a manner consistent with it having mixed with the same convective airmass that produced the anvil. Unlike surrounding air, the TTC had embedded a monochromatic gravity wave with a wavelength of 2 km and an amplitude of several hundred meters. Combined, this evidence, supported by a photograph from CRYSTAL-FACE, leads to the conjecture that the TTC originated as a pileus cloud layer, which formed near the tropopause ahead of vigorous convective uplift. We hypothesize that the pileus was penetrated by the convection, moistened through mixing, and once the convection subsided, it was sustained by radiative cooling due to the presence of the anvil layer beneath.

Garrett, T. J.↗

Characterization of a Low-Temperature Plasma (LTP) Ambient Ionization Source Using Temporally Resolved Monochromatic Imaging Spectrometry

The low-temperature plasma (LTP) probe is a common plasma-based source used for ambient desorption–ionization mass spectrometry (MS). While the LTP probe has been characterized in detail with MS, relatively few studies have used optical spectroscopy. In this paper, two-dimensional (2D) imaging at selected wavelengths is used to visualize important species in the LTP plasma jet. First, 2D steady-state images of the LTP plume for N 2 + (391.2 nm), He I (706.5 nm), and N 2 (337.1 nm) emissions were recorded under selected plasma conditions. Second, time-resolved 2D emission maps of radiative species in the LTP plasma jet were recorded through the use of a 200 ns detection gate and varying gate delays with respect to the LTP trigger pulse. Emission from He I, N 2 + , and N 2 in the plasma jet region was found to show a transient behavior (often referred to as plasma bullets) lasting only a few microseconds. The N 2 + and He I maps were highly correlated in spatial and temporal structure. Further, emission from N 2 showed two maxima in time, one before and one after the maximum emission for N 2 + and He I, due to an initial electronic excitation wave and ion–electron recombination, respectively. Third, the interaction of the LTP probe with a sample substrate and an electrically grounded metallic needle was studied. Emission from a fluorophore on the sample substrate showed an initial photon-induced excitation from plasma-generated photons followed by electronic excitation by other plasma species. The presence of a grounded needle near the plasma jet significantly extended the plasma jet lifetime and also generated a long-lived corona discharge on the needle. The effect of LTP operating parameters on emission spectra was correlated with mass-spectral results including reagent-ion signals. Lastly, five movies provide a side-by-side comparison of the temporal behavior of emitting species and insights into the interactions of the emission clouds with a sample surface as well as an external needle. Temporally and spatially resolved imaging provided insights into important processes in the LTP plasma jet, which will help improve analyte ion sampling in LTP–MS.

Chan, George C. -Y.↗

Observation of early shell-dopant mix in OMEGA direct-drive implosions and comparisons with radiation-hydrodynamic simulations

Temporally, spatially, and spectrally resolved x-ray image data from direct-drive implosions on OMEGA were interpreted with the aid of radiation-hydrodynamic simulations. Neither clean calculations nor those using a turbulent mix model can explain fully the observed migration of shell-dopant material (titanium) into the core. Shell-dopant migration was observed via time-dependent, spatially integrated spectra, and spatially and spectrally resolved x-ray images of capsule implosions and resultant dopant emissions. The titanium emission was centrally peaked in narrowband x-ray images. In post-processed clean simulations, the peak titanium emission forms in a ring in self-emission images as the capsule implodes. Post-processed simulations with mix reproduce trends in time-dependent, spatially integrated spectra, as well having centrally peaked Ti emission in synthetic multiple monochromatic imager. However, mix simulations still do not transport Ti to the core as is observed in the experiment. This suggests that phenomena in addition to the turbulent mix must be responsible for the transport of Ti. Simple diffusion estimates are unable to explain the early Ti mix into the core. Mechanisms suggested for further study are capsule surface roughness, illumination non-uniformity, and shock entrainment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Emerging monochromatic fluxes and colors of red degenerate stars

The emerging monochromatic fluxes and the B-V, V-I, J-H, and V-K color indices are presented for red degenerate stars with helium atmospheres which were calculated using an equation of state and opacities based on a hot Thomas-Fermi model of the helium gas. The effective temperature range is 4500-2500 K. It is found that although the emerging fluxes resemble blackbody curves, red degenerates emit more radiation than blackbodies in the short wavelength range and less in the long wavelength range. Thus, red degenerates appear bluer than blackbodies of the same temperature. The calculated colors of these models are compared to the colors of some of the coolest known non-DA degenerate stars. In particular it is found that the B-V and V-I colors of the cool white dwarf VB 11, whose temperature had been previously estimated to be higher than 4000 K, suggest a temperature of 3750 K. If this result is correct, then VB 11 is probably the coolest known white dwarf.

Kapranidis, S.↗

Speckle correlation as a monitor of X-ray free-electron laser induced crystal lattice deformation

X-ray free-electron lasers (X-FELs) present new opportunities to study ultrafast lattice dynamics in complex materials. While the unprecedented source brilliance enables high fidelity measurement of structural dynamics, it also raises experimental challenges related to the understanding and control of beam-induced irreversible structural changes in samples that can ultimately impact the interpretation of experimental results. This is also important for designing reliable high performance X-ray optical components. In this work, X-FEL beam-induced lattice alterations are investigated by measuring the shot-to-shot evolution of near-Bragg coherent scattering from a single crystalline germanium sample. It is shown that X-ray photon correlation analysis of sequential speckle patterns measurements can be used to monitor the nature and extent of lattice rearrangements. Additionally, abrupt, irreversible changes are observed following intermittent high-fluence monochromatic X-ray pulses, thus revealing the existence of a threshold response to X-FEL pulse intensity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Test of a prototype neutron spectrometer based on diamond detectors in a fast reactor

A prototype of neutron spectrometer based on diamond detectors has been developed. This prototype consists of a {sup 6}Li neutron converter sandwiched between two CVD diamond crystals. The radiation hardness of the diamond crystals makes it suitable for applications in low power research reactors, while a low sensitivity to gamma rays and low leakage current of the detector permit to reach good energy resolution. A fast coincidence between two crystals is used to reject background. The detector was read out using two different electronic chains connected to it by a few meters of cable. The first chain was based on conventional charge-sensitive amplifiers, the other used a custom fast charge amplifier developed for this purpose. The prototype has been tested at various neutron sources and showed its practicability. In particular, the detector was calibrated in a TRIGA thermal reactor (LENA laboratory, University of Pavia) with neutron fluxes of 10{sup 8} n/cm{sup 2}s and at the 3 MeV D-D monochromatic neutron source named FNG (ENEA, Rome) with neutron fluxes of 10{sup 6} n/cm{sup 2}s. The neutron spectrum measurement was performed at the TAPIRO fast research reactor (ENEA, Casaccia) with fluxes of 10{sup 9} n/cm{sup 2}s. The obtained spectra were compared to Monte Carlo simulations, modeling detector response with MCNP and Geant4. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

First observations from the Kr multi-monochromatic x-ray imager for time and spatially resolved diagnosis of hot implosion cores

This paper presents initial findings from the recently deployed Kr multi-monochromatic x-ray imager (Kr MMI) at the Omega laser facility. The experiment focuses on exploring implosion dynamics in exploding pusher capsules at three distinct initial gas fill densities. Utilizing time-gated and spatially integrated measurements, core size, electron temperature (Te), and electron densities (ne) are extracted through the analysis of the spectral region encompassing the Kr He α and its satellite lines. A comprehensive spectral database, incorporating atomic kinetics, spectroscopic-quality radiation transport, and Stark broadened line shapes, has been developed for rigorous data analysis. These measurements underscore the utility of the new Kr MMI instrument, which, combined with sophisticated analysis techniques, enables the diagnosis of plasma conditions at Te>2000 eV, thereby extending the capabilities beyond the prior Ar MMI design. This is an important stepping stone for achieving time-gated and space-resolved diagnostics of electron temperature, electron density, and heat transport in high temperature implosion cores.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An inverse free electron laser acceleration-driven Compton scattering X-ray source

Abstract The generation of X-rays and γ-rays based on synchrotron radiation from free electrons, emitted in magnet arrays such as undulators, forms the basis of much of modern X-ray science. This approach has the drawback of requiring very high energy, up to the multi-GeV-scale, electron beams, to obtain the required photon energy. Due to the limit in accelerating gradients in conventional particle accelerators, reaching high energy typically demands use of instruments exceeding 100’s of meters in length. Compact, less costly, monochromatic X-ray sources based on very high field acceleration and very short period undulators, however, may enable diverse, paradigm-changing X-ray applications ranging from novel X-ray therapy techniques to active interrogation of sensitive materials, by making them accessible in energy reach, cost and size. Such compactness and enhanced energy reach may be obtained by an all-optical approach, which employs a laser-driven high gradient accelerator based on inverse free electron laser (IFEL), followed by a collision point for inverse Compton scattering (ICS), a scheme where a laser is used to provide undulator fields. We present an experimental proof-of-principle of this approach, where a TW-class CO 2 laser pulse is split in two, with half used to accelerate a high quality electron beam up to 84 MeV through the IFEL interaction, and the other half acts as an electromagnetic undulator to generate up to 13 keV X-rays via ICS. These results demonstrate the feasibility of this scheme, which can be joined with other techniques such as laser recirculation to yield very compact photon sources, with both high peak and average brilliance, and with energies extending from the keV to MeV scale. Further, use of the IFEL acceleration with the ICS interaction produces a train of high intensity X-ray pulses, thus enabling a unique tool synchronized with a laser pulse for ultra-fast strobe, pump-probe experimental scenarios.

43 PARTICLE ACCELERATORS↗

A novel, magnetically driven convergent Richtmyer–Meshkov platform

Here, we introduce a novel experimental platform for the study of the Richtmyer–Meshkov instability in a cylindrically converging geometry using a magnetically driven cylindrical piston. Magnetically driven solid liner implosions are used to launch a shock into a liquid deuterium working fluid and, ultimately, into an on-axis rod with a pre-imposed perturbation. The shock front trajectory is tracked through the working fluid and up to the point of impacting the rod through the use of on axis photonic Doppler velocimetry. This configuration allows for precise characterization of the shock state as it impacts the perturbed rod interface. Monochromatic x-ray radiography is used to measure the post-shock interface evolution and rod density profile. The ALEGRA MHD model is used to simulate the dynamics of the experiment in one dimension. We show that late in time the perturbation growth becomes non-linear as evidenced by the observation of high-order harmonics, up to n = 5. Two dimensional simulations performed using a combination of the GORGON MHD code and the xRAGE radiation hydrodynamics code suggest that the late time non-linear growth is modified by convergence effects as the bubbles and spikes experience differences in the pressure of the background flow.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct observation of tetrahertz electromagnetic waves emitted from intrinsic Josephson junctions in single crystallie Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+{delta}}.

We have observed intense, coherent, continuous and monochromatic electromagnetic (EM) emission at terahertz frequencies generated from a single crystalline mesa structure of the high-T{sub c} superconductor Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+{delta}} intrinsic Josephson junction system. The mesa is fabricated by the Argon-ion-milling and photolithography techniques on the cleaved surface of Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+{delta}} single crystal. The frequency, {nu}, of the EM radiation observed from the sample obeys simple relations: {nu} = c/n{lambda} = c/2nw and {nu} = 2eV/hN, where c is the light velocity in vacuum, n the refractive index of a superconductor, {lambda} the wave length of the EM emission in vacuum, w the shorter width of the mesa, V the voltage applied to the mesa, N the number of layers of intrinsic Josephson junctions, e and h are the elementary charge and the Planck constant, respectively. These two relations strongly imply that the mechanism of the emission is, firstly, due to the geometrical resonance of EM waves to the mesa like a cavity resonance occuring in the mesa structure, and forming standing waves as cavity resonance modes, and secondly, due to the ac-Josephson effect, which works coherently in all intrinsic Josephson junctions. The peculiar temperature dependence of the power intensity emitted form samples shows a broad maximum in a temperature region between 20 and 40 K, suggesting that the nonequilibrium effect plays an essential role for the emission of EM waves in this system. The estimated total power is significantly improved in comparison with the previous report [L. Ozyuzer et al., Science 318 (2007) 1291, K. Kadowaki, et al., Physica C 437-438 (2006) 111, I.E. Batov, et al., Appl. Phys. Lett. 88 (2006) 262504], and reached as high as 5 {micro}W from single mesa with w = 60 {micro}m at 648 GHz, which enables us to use it for some of applications. So far, we succeeded in fabricating the mesa emitting EM waves up to 960 GHz in the fundamental mode in the w = 40 {micro}m mesa, whereas the higher harmonics up to the 4-th order were observed, resulting in a frequency exceeding 2.5 THz. In sharp contrast to the previous reports [K. Kadowaki, et al., Physica C 437-438 (2006) 111, M.-H. Bae, et al., Phys. Rev. Lett. 98, (2007) 027002], all the present measurements were done in zero magnetic field. Lastly, a plausible theoretical model for the mechanism of emission is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A critical evaluation of semianalytic methods in the study of centrally heated, unresolved, infrared sources

We critically evaluate current methods of analysis in infrared (IR) astronomy and investigate the conditions under which these semianalytic methods are reliable. Specifically we examine the usual assumptions of homogeneities in dust density and temperature, and neglect of opacity effects when applied to internally heated, unresolved IR sources. To accomplish this, a series of radiation transport models for these sources have been constructed. The model results are treated as observed quantities and analyzed to derive the source parameters, using simple semianalytic methods. The discrepancies between the derived and actual model parameters can then be attributed to the limitations of the analysis methods and provide a measure of their reliability. Applying this approach to centrally heated, unresolved IR sources, we have studied in detail the following diagnostic problems: (1) determination of dust mass from monochromatic and integrated luminosities; (2) estimation of dust temperature distribution from color temperatures derived from the flux spectrum; and (3) determination of the empirical grain emissivity law (opacity function) for both continuum and spectral features.

Doty, Steven D.↗

Accelerated line-by-line calculation of spectral absorption coefficients with high numerical accuracy

To model radiative transfer through the atmosphere with high accuracy, one must resort to the calculation of spectral absorption coefficients on a line-by-line basis. The calculation of these coefficients is computationally expensive for three reasons: (1) thousands of spectral lines can contribute to absorption at a single frequency; (2) the tails of spectral line profiles are long (i.e., a given line can contribute to absorption over a wide range of frequencies); and (3) the sampling frequencies at which monochromatic radiances are to be calculated must be spaced sufficiently close together to resolve the thinnest lines of interest (e.g., those that arise in the stratosphere). We have developed a new algorithm to accelerate the calculation of spectral absorption coefficients while retaining high numerical accuracy.

Sparks, L.↗

Intense quasi-monochromatic resonant harmonic generation in the multiphoton ionization regime

Resonant high-order harmonics, which result in quasimonochromatic extreme ultraviolet light with coherent intensity enhancement involving autoionizing resonances, have been demonstrated from laser-ablated plumes in the tunnel-ionization regime. Here, we demonstrate resonant harmonics in the previously unexplored multiphoton-ionization regime. We demonstrate an intense resonant harmonic from gallium with an intensity enhancement ratio of 714 relative to the neighboring harmonics, achieved without the need for extreme ultraviolet filtering methods, thus preventing a typical photon flux loss of more than 70%. Three-dimensional time-dependent Schrödinger equation calculations reveal that this increase in the enhancement ratio is due to the lowelectron wave packet spreading in the multiphoton-ionization regime. These results reveal a method for increasing the intensity and monochromaticity of intense multimicrojoule femtosecond extreme ultraviolet light and will also facilitate understanding of the involvement of autoionizing resonances in generating resonant harmonics in the multiphoton-ionization regime.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of Experimental Techniques Using LVP (Large Volume Press) at GSECARS Beamlines, Advanced Photon Source (in Japanese with English abstract)

GSECARS (GeoSoilEnviroCARS, the University of Chicago) operates a bending magnet and an undulator beamlines at Sector 13, Advanced Photon Source. Experimental technique for High Pressure X-ray Tomographic Microscope (HPXTM) using monochromatized X-rays has been developed. The module for HPXTM also has shear deformation capability, which enables us to perform HPXTM experiments for microstructure developed by shear deformation under high pressure. A combination of Deformation DIA (D-DIA) and monochromatic X-rays has been developed for quantitative deformation experiments under pressure above 10 GPa. Deformation experiments of e-iron was performed at pressures up to 19 GPa and temperatures up to 700 K.

43 PARTICLE ACCELERATORS↗

LANDSAT-D investigations in snow hydrology

Thematic mapper data for the southern Sierra Nevada area were registered to digital topographic data and compared to LANDSAT MSS and NOAA-7 AVHRR data of snow covered areas in order to determine the errors associated with using coarser resolution and to qualify the information lost when high resolution data are not available. Both the zenith and the azimuth variations in the radiative field are considered in an atmospheric radiative transfer model which deals with a plane parallel structured atmosphere composed of different layers, each assumed to be homogeneous in composition and to have a linear in tau temperature profile. Astronomical parameters for each layer are Earth-Sun distance and solar flux at the top of the atmosphere. Atmospheric parameters include pressure temperature, chemical composition of the air molecules, and the composition and size of the aerosol, water droplets, and ice crystals. Outputs of the model are the monochromatic radiance and irradiance at each level. The use of the model in atmospheric correction of remotely sensed data is discussed.

Dozier, J.↗

Development and performance test of a soft x-ray polarimeter and ellipsometer for complete polarization analysis

A new apparatus for polarimetric and ellipsometric measurements based on the rotating-analyzer method in the soft x-ray region has been designed, constructed, and installed in the soft x-ray beamline (BL-11) at the SR Center of Ritsumeikan University, Shiga, Japan. It can realize the optical configurations for the complete polarization analysis by using six independently movable drive shafts. A demonstration of the capabilities of the apparatus has been performed using Mo/Si multilayer polarizers deposited by an ion beam sputtering method. It is for the first time shown that the degree of linear polarization of monochromatized light from the BL-11 is approximately 87% at 92 eV since the beamline has been constructed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗