Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material Point Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Influence of Technologic Advances on Outcomes in Patients With Unresectable, Locally Advanced Non-Small-Cell Lung Cancer Receiving Concomitant Chemoradiotherapy

Purpose: In 2004, our institution began using four-dimensional computed tomography (4DCT) simulation and then intensity-modulated radiotherapy (IMRT) (4DCT/IMRT) instead of three-dimensional conformal radiotherapy (3DCRT) for the standard treatment of non-small-cell lung cancer (NSCLC). This retrospective study compares disease outcomes and toxicity in patients treated with concomitant chemotherapy and either 4DCT/IMRT or 3DCRT. Methods and Materials: A total of 496 NSCLC patients have been treated at M. D. Anderson Cancer Center between 1999 and 2006 with concomitant chemoradiotherapy. Among these, 318 were treated with CT/3DCRT and 91 with 4DCT/IMRT. Both groups received a median dose of 63 Gy. Disease end points were locoregional progression (LRP), distant metastasis (DM), and overall survival (OS). Disease covariates were gross tumor volume (GTV), nodal status, and histology. The toxicity end point was Grade >=3 radiation pneumonitis; toxicity covariates were GTV, smoking status, and dosimetric factors. Data were analyzed using Cox proportional hazards models. Results: Mean follow-up times in the 4DCT/IMRT and CT/3DCRT groups were 1.3 (range, 0.1-3.2) and 2.1 (range, 0.1-7.9) years, respectively. The hazard ratios for 4DCT/IMRT were <1 for all disease end points; the difference was significant only for OS. The toxicity rate was significantly lower in the IMRT/4DCT group than in the CT/3DCRT group. V20 was significantly higher in the 3DCRT group and was a significant factor in determining toxicity. Freedom from DM was nearly identical in both groups. Conclusions: Treatment with 4DCT/IMRT was at least as good as that with 3DCRT in terms of the rates of freedom from LRP and DM. There was a significant reduction in toxicity and a significant improvement in OS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Widespread Dependence of Backup NHEJ on Growth State: Ramifications for the Use of DNA-PK Inhibitors

Purpose: The backup pathway of nonhomologous end joining (B-NHEJ) enables cells to process DNA double-strand breaks (DSBs) when the DNA-PK-dependent pathway of NHEJ (D-NHEJ) is compromised. Our previous results show marked reduction in the activity of B-NHEJ when LIG4{sup -/-} mouse embryo fibroblasts (MEFs) cease to grow and enter a plateau phase. The dependence of B-NHEJ on growth state is substantially stronger than that of D-NHEJ and points to regulatory mechanisms or processing determinants that require elucidation. Because the different D-NHEJ mutants show phenotypes distinct in their details, it is necessary to characterize the dependence of their DSB repair capacity on growth state and to explore species-specific responses. Methods and Materials: DSB repair was measured in cells of different genetic background from various species using pulsed-field gel electrophoresis, or the formation of {gamma}-H2AX foci, at different stages of growth. Results: Using pulsed-field gel electrophoresis, we report a marked reduction of B-NHEJ during the plateau phase of growth in KU and XRCC4, mouse or Chinese hamster, mutants. Notably, this reduction is only marginal in DNA-PKcs-deficient cells. However, reduced B-NHEJ is also observed in repair proficient, plateau-phase cells after treatment with DNA-PK inhibitors. The reduction of B-NHEJ activity in the plateau phase of growth does not derive from the reduced expression of participating proteins, is detectable by {gamma}-H2AX foci analysis, and leads to enhanced cell killing. Conclusions: These results further document the marked dependence on growth state of an essential DSB repair pathway and show the general nature of the effect. Molecular characterization of the mechanism underlying this response will help to optimize the administration of DNA repair inhibitors as adjuvants in radiation therapy.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Radiation Therapy in Primary Mediastinal B-Cell Lymphoma With Positron Emission Tomography Positivity After Rituximab Chemotherapy

Purpose: To investigate the role of radiation therapy (RT) in patients affected with primary mediastinal B-cell lymphoma (PMBCL) with residual {sup 18}fluorodeoxyglucose positron emission tomography ({sup 18}FDG-PET)-positive disease after rituximab chemotherapy (R-CT). Methods and Materials: Thirty-seven patients treated with R-CT and RT, all with {sup 18}FDG-PET scan at diagnosis and before RT, were included. All {sup 18}FDG-PET scans were reviewed, and responses were classified according to the Deauville 5-point scoring system. Outcomes measures were overall survival (OS) and progression-free survival (PFS), estimated for the whole cohort and for subgroups according to {sup 18}FDG-PET score after R-CT. Results: The median follow-up time was 40.9 months. Three patients were assigned to Deauville score 1 (8.1%), 9 to score 2 (24.3%), 7 to score 3 (19%), 14 to score 4 (37.8%), and 4 to score 5 (10.8%). After RT, all patients with score 3-4 experienced a complete response (CR). Among patients with score 5, 1 was in CR (25%), 2 had persistent positivity (50%), and 1 showed progressive disease (25%). A total of 4 patients experienced progression or relapse: 1 of 33 (3%) with scores 1-4, and 3 of 4 (75%) with score 5. The 3-year OS and PFS of the whole cohort were 89.8% and 88.7%, respectively. OS was significantly different between scores 1-3 and scores 4-5 (100% vs 77% at 3 years, P<.05). Patients with a score of 5 had a significantly worse outcome than did all other patients (OS at 2 years, 33.3% vs 100%). Conclusions: Approximately 50% of PMBCL patients show residual disease at {sup 18}FDG-PET scan after R-CT. RT is able to convert to CR approximately 85% of these patients, but those with a Deauville score of 5 (10%) appear at high risk of progression and death, and they might be candidates for intensified programs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Controlled drug release on amine functionalized spherical MCM-41

MCM-41 silica with spherical morphology and small particle sizes (100 nm) was synthesized and modified by post-synthesis method with different amounts of 3-aminopropyltriethoxysilane (APTES). A comparative study of the adsorption and release of a model drug, ibuprofen, was carried out. The modified and drug loaded mesoporous materials were characterized by XRD, TEM, N{sub 2} physisorption, elemental analysis, thermal analysis and FT-IR spectroscopy. A new method was developed for the quantitative determination of amino groups in surface modified mesoporous materials by the ninhydrin reaction. Good correlation was found between the amino content of the MCM-41 materials determined by the ninhydrin method and their ibuprofen adsorption capacity. Amino modification resulted in high degree of ibuprofen loading and slow release rate in comparison to the parent non-modified MCM-41. - Graphical abstract: Determination of surface amino groups by ninhidrin method. Highlights: Black-Right-Pointing-Pointer Spherical MCM-41 modified by different amounts of APTES was studied. Black-Right-Pointing-Pointer Ibuprofen (IBU) adsorption and release characteristics was tested. Black-Right-Pointing-Pointer The ninhydrin reaction was used for the quantitative determination of amino groups. Black-Right-Pointing-Pointer Stoichiometric amount of APTES is enough for totally covering the surface with amino groups. Black-Right-Pointing-Pointer Good correlation was found between the amino content and IBU adsorption capacity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reduced Artifact Approach for Determining Diffusion Coefficients in Time-Resolved Microscopy

Ultrafast microscopy methods traditionally assume a Gaussian profile to extract excited state diffusivities from transport measurements. Although this fitting method recovers accurate diffusion coefficients when the point spread function is well-represented by a Gaussian, even minor spatial aberrations introduced by the imaging system cause significant errors in the determined value. To provide a more accurate measure of excited state transport in nano- and microscale materials systems, in this work an alternative analysis protocol is proposed that numerically convolves the Green’s function solution to the diffusion equation with the experimentally measured point spread function. In contrast to the Gaussian fitting approach, the numerical convolution is shown to be robust against artifacts caused by nonideal point spread functions. Furthermore, the numerical convolution approach is highly effective at resolving anisotropic diffusion in modeled data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Second Harmonic Generation Electric Field Triplet Interferometry for Absolute Phasing

We report second harmonic generation (SHG) electric field triplet interferometry performed using three mutually coherent ultrafast pulses in a common path with controllable relative phases, namely, the light fields of a sample signal (SI), a reference oscillator (RO), and a local oscillator (LO). The ROLO phase determined from the interference of the light fields produced by two quartz wafers is subtracted from the phase determined from the SIROLO interferogram to yield the signal phase, ϕ SI . The new method also calibrates the measured SHG intensity from a given sample internally by sending the fundamental light field reflected from the sample into one of the quartz wafers in the ROLO element. The approach avoids having to exchange the sample against a reference material with a known χ(2) value or known phase and accounts on-the-fly for situations where the reflected fundamental light field intensity changes with experimental conditions. The new method is successfully benchmarked against z-cut α-quartz, fused silica held at its point of zero charge, and hematite nanolayers in air, across three different interferometers. Furthermore, the approach should be applicable for other second-order nonlinear spectroscopies, such as vibrational or electronic sum-frequency generation.

Interfaces↗

IDENTIFYING FRACTURE ORIGIN IN CERAMICS BY COMBINATION OF NONDESTRUCTIVE TESTING AND DISCRETE ELEMENT ANALYSIS

Advanced ceramic materials have been extensively applied in aerospace, automobile and other industries. However, the reliability of the advanced ceramics is a major concern because of the brittle nature of the materials. In this paper, combination of nondestructive testing and numerical modeling Discrete Element Method is proposed to identify the fracture origin in ceramics. The nondestructive testing--laser scattering technology is first performed on the ceramic components to reveal the machining-induced damage such as cracks and the material-inherent flaws such as voids, then followed by the four point bending test. Discrete Element software package PFC{sup 2D} is used to simulate the four point bending test and try to identify where the fractures start. The numerical representation of the ceramic materials is done by generating a densely packed particle system using the specimen genesis procedure and then applying the suitable microparameters to the particle system. Simulation of four point bending test is performed on materials having no defects, materials having manufacturing-induced defects like cracks, and materials having material-inherent flaws like voids. The initiation and propagation of defects is modeled and the mean contact force on the loading ball is also plotted. The simulation prediction results are well in accordance with the nondestructive testing results.

36 MATERIALS SCIENCE↗

Oxygen incorporation effects in annealed epitaxial La{sub (1-x)}Sr{sub x}MnO{sub 3} thin films

This paper presents our results regarding oxygen incorporation effects in epitaxial La{sub (1-x)}Sr{sub x}MnO{sub 3} thin films, deposited on SrTiO{sub 3} (001) single crystal substrates, by annealing in different gas mixtures of argon and oxygen. A particular emphasis is placed on the correlation of structural properties with the magnetic properties of the films, Curie temperature, and coercive field. In this sense, we demonstrate that the evolution of the diffuse part of the {omega}-scans performed on the films are due to oxygen excess in the film lattice, which creates cationic vacancies within the films. Also, we show that two regimes of oxygen incorporation in the films exist, one in which the films evolve toward a single phase and oxygen stoichiometry is recovered, and a second one dominated by oxygen over-doping effects. In order to support our study, XPS measurements were performed, from which we have evaluated the Mn{sup 3+}/Mn{sup 4+} ionic ratio.

36 MATERIALS SCIENCE↗

Locally defined quantum emission from epitaxial few-layer tungsten diselenide

Recently, single photons have been observed emanating from point defects in two-dimensional (2D) materials including WSe 2 , WS 2 , hexagonal-BN, and GaSe, with their energy residing in the direct electronic bandgap. Here, we report single photon emission from a nominal weakly emitting indirect bandgap 2D material through deterministic strain induced localization. A method is demonstrated to create highly spatially localized and spectrally well-separated defect emission sites in the 750–800 nm regime in a continuous epitaxial film of few-layer WSe 2 synthesized by a multistep diffusion-mediated gas source chemical vapor deposition technique. To separate the effects of mechanical strain from the substrate or dielectric-environment induced changes in the electronic structure, we created arrays of large isotropically etched ultrasharp silicon dioxide tips with spatial dimensions on the order of 10 μm. We use bending based on the small radius of these tips—on the order of 4 nm—to impart electronic localization effects through morphology alone, as the WSe 2 film experiences a uniform SiO 2 dielectric environment in the device geometry chosen for this investigation. When the continuous WSe 2 film was transferred onto an array of SiO 2 tips, an ~87% yield of localized emission sites on the tips was observed. The outcomes of this report provide fundamental guidelines for the integration of beyond-lab-scale quantum materials into photonic device architectures for all-optical quantum information applications.

36 MATERIALS SCIENCE↗

Impact of Blast Overpressure on the Pharmacokinetics of Various Antibiotics in Sprague Dawley Rats

ABSTRACT Introduction Combat injuries are complex and multimodal. Most injuries to the extremities occur because of explosive devices such as improvised explosive devices. Blast exposure dramatically increases the risk of infection in combat wounds, and there is limited available information on the best antibiotic treatments for these injuries. We previously demonstrated that mice exposed to blast displayed a delayed clearance of cefazolin from the plasma and liver; further semi-mechanistic modeling determined that cefazolin concentrations in the skin of these mice were reduced. Our objective was to investigate the effects of blast on the pharmacokinetics of antibiotics of different types used for the treatment of combat wounds in the rat model. Materials and Methods Male Sprague Dawley rats were exposed to blast overpressure followed by injection of a bolus of animal equivalent doses of an antibiotic (cefazolin, cefepime, ertapenem, or clindamycin) into the tail vein at 1-hour post-blast exposure. Blood was collected at predetermined time points via repeated sampling from the tail vein. Animals were also euthanized at predetermined time points, at which time liver, kidney, skin, and blood via cardiac puncture were collected. Antibiotic concentrations were determined by ultra-performance liquid chromatography–tandem mass spectrometry. Results Blast-exposed rats exhibited a similar rate of clearance compared to non-blasted rats in the blood, liver, kidney, and skin, which is inconsistent with the data regarding cefazolin in blast-exposed mice. Conclusions Our results in rats do not recapitulate our previous observation of delayed cefazolin clearance in mice following the blast overpressure exposure. Although using rats permitted us to collect multiple blood samples from the same animals, rats may not be a suitable model for measuring the pharmacokinetics of antibiotics following blast. The interpretation of the results may be challenging because of variation in data among rat subjects in the same sample groups.

General & Internal Medicine↗

First principles-based multiscale atomistic methods for input into first principles nonequilibrium transport across interfaces

This issue of PNAS features “nonequilibrium transport and mixing across interfaces,” with several papers describing the nonequilibrium coupling of transport at interfaces, including mesoscopic and macroscopic dynamics in fluids, plasma, and other materials over scales from microscale to celestial. Most such descriptions describe the materials in terms of the density and equations of state rather than specific atomic structures and chemical processes. It is at interfacial boundaries where such atomistic information is most relevant. However, there is not yet a practical way to couple these phenomena with the atomistic description of chemistry. The starting point for including such information is the quantum mechanics (QM). However, practical QM calculations are limited to a hundred atoms for dozens of picoseconds, far from the scales required to inform the continuum level with the proper atomistic description. To bridge this enormous gap, we need to develop practical methods to extend the scale of the atomistic simulation by several orders of magnitude while retaining the level of QM accuracy in describing the chemical process. Here, these developments would enable continuum modeling of turbulent transport at interfaces to incorporate the relevant chemistry. In this perspective, we will focus on recent progress in accomplishing these extensions in first principles-based atomistic simulations and the strategies being pursued to increase the accuracy of very large scales while dramatically decreasing the computational effort.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Submerged Fatigue Testing of Marine Energy Advanced Materials

Marine energy structures are typically made of advanced composite materials and are subjected to extreme ocean environments in service. In extreme ocean environments, seawater currents and waves load structures repeatedly, which cause two environmental conditions: water intrusion and mechanical fatigue. In prior research, the two environmental conditions were applied sequentially, where composite specimens were aged and then mechanically tested. To understand the combined effects of dynamic loading and water intrusion on composite materials, the present study involves the static and fatigue four-point bend testing of composite coupons in a water tank. The water tank was designed and built to fit either a 100 kN or a 250 kN load frame. Flexural strength value, cycles to failure, and failure mode results from submerged fatigue testing will be used to inform marine energy structure designs. The coupon-scale test method will be used to scale up to and inform methods for subsequent subcomponent testing and standards development. Finally, the benefits of designing marine energy structures to informed standards are decreased lifetime costs and increased reliability and energy production, ultimately leading to a sustainable and low-carbon energy system.

13 HYDRO ENERGY↗

Electrochemical techniques and mechanisms for the corrosion of metals and alloys in sub- and supercritical aqueous systems

Corrosion has become a decisive factor hindering supercritical water technologies' long-cycle, safe implementation. Electrochemical experiments performed in supercritical aqueous systems can capture essential, real-time information about the micro/nanoscale processes of corrosion and their kinetics. As a starting point, this paper first summarizes the critical chemical properties of supercritical aqueous systems and analyzes their role in determining the duality of corrosion mechanisms (whether electrochemical or chemical micro-processes predominate). Next, it reviews the available electrochemical techniques such as pH sensors, electrochemical noise measurements, and related applications for quantitatively elaborating the corrosion issues in supercritical aqueous systems. With thick and heavy colors, a series of mechanistic models, such as the mixed potential model and the coupled environment models were introduced from the fundamental theories to the related applications, which have been applied widely in ambient and subcritical aqueous systems and exhibit great values and potential to be employed in high-density supercritical water environments. The passivity, depassivation, and passivity breakdown of metals and alloys in terms of the Point Defect Model (PDM) were also successfully implemented and discussed. Further, the newly built SCW_PDM describes the film growth kinetics at the atomic level of metals and alloys in supercritical water and is being developed to quantitatively analyze and resolve a series of corrosion issues such as the passivity breakdown and the stress corrosion cracking that occur in supercritical aqueous systems. This review is helpful by promoting the development of the electrochemical corrosion theory in supercritical aqueous systems and by identifying corrosion prevention and control methods for the safe implementation of relevant supercritical water technologies.

36 MATERIALS SCIENCE↗

Solid-State Joining of Magnesium Sheet to High-Strength Steel

Increasing the use of lightweight materials and implementing enabling manufacturing technologies are the two primary paths toward automotive weight reduction. In many situations, the ability to substitute light weight material requires a need to attach and join light weight material to existing steel substructures requiring dissimilar joining technologies. Dissimilar joining methods currently available in cost range for high volume automotive manufacturing face multiple challenges. The problem is exacerbated in the case of Magnesium alloy to steel joints because of their highly dissimilar nature and lack of mutual miscibility. Additionally, Magnesium’s poor room temperature ductility complicates the use of point fastening technologies. Two emerging solid-state joining technologies Friction Stir assisted Scribe welding (FaST) and Ultrasonic Welding (USW) that employ large amount of plastic deformation at the interface were used to investigate, develop, and understand dissimilar joints between Magnesium Alloy to DP590 Steel. Various process responses including interface temperatures, process forces, strain fields were captured during the development of the welding process. Variety of welded samples were tested and characterized to understand the relationship between welding conditions and joints microstructure and mechanical properties.

36 MATERIALS SCIENCE↗

Structural, electronic and thermodynamic properties of R{sub 3}ZnH{sub 5} (R=K, Rb, Cs): A first-principle calculation

R{sub 3}ZnH{sub 5} (R=K, Rb, Cs) series have been investigated with respect to the crystal structure, electronic and thermodynamic properties using first-principle methods based on density functional theory with generalized gradient approximation. The optimized structures and atomic coordinates are in good agreement with the experimental data. The strong covalent interactions are obtained between Zn and H atoms in the 18-electron [ZnH{sub 4}]{sup 2-} complex, while an ionic interaction is found between [ZnH{sub 4}]{sup 2-} and R atom. The formation enthalpies show that the formations of R{sub 3}ZnH{sub 5} hydrides are all exothermic at 298 K. The vibration free energies of R{sub 3}ZnH{sub 5} show that the thermodynamic stabilities of R{sub 3}ZnH{sub 5} hydrides decrease with the increasing diameter of R atom. Two possible decomposition reactions of R{sub 3}ZnH{sub 5} series have been suggested in our work. One (reaction one) is that R{sub 3}ZnH{sub 5} hydrides decomposes to elements directly, and the other (reaction two) is that R{sub 3}ZnH{sub 5} hydrides decomposes to RH hydride. The results show that the first decomposition reaction is more favorable one. The spontaneous decomposition reaction of K{sub 3}ZnH{sub 5} hydrides occur upon 465 K via reaction one, and 564 K via reaction two, respectively. - Graphical abstract: Total charge density of K{sub 3}ZnH{sub 5}. Highlights: Black-Right-Pointing-Pointer Electronic and thermodynamic properties of R{sub 3}ZnH{sub 5} (R=K, Rb, Cs) were calculated. Black-Right-Pointing-Pointer The formations of R{sub 3}ZnH{sub 5} hydrides are all exothermic at 298 K. Black-Right-Pointing-Pointer The thermodynamic stabilities decrease with the increasing diameter of R atom. Black-Right-Pointing-Pointer Two possible decomposition pathways of R{sub 3}ZnH{sub 5} were investigated.

36 MATERIALS SCIENCE↗

A simple differential steady-state method to measure the thermal conductivity of solid bulk materials with high accuracy

Accurate measurements of thermal conductivity are of great importance for materials research and development. Steady-state methods determine thermal conductivity directly from the proportionality between heat flow and an applied temperature difference (Fourier Law). Although theoretically simple, in practice, achieving high accuracies with steady-state methods is challenging and requires rather complex experimental setups due to temperature sensor uncertainties and parasitic heat loss. We developed a simple differential steady-state method in which the sample is mounted between an electric heater and a temperature-controlled heat sink. Our method calibrates for parasitic heat losses from the electric heater during the measurement by maintaining a constant heater temperature close to the environmental temperature while varying the heat sink temperature. This enables a large signal-to-noise ratio which permits accurate measurements of samples with small thermal conductance values without an additional heater calibration measurement or sophisticated heater guards to eliminate parasitic heater losses. Additionally, the differential nature of the method largely eliminates the uncertainties of the temperature sensors, permitting measurements with small temperature differences, which is advantageous for samples with high thermal conductance values and/or with strongly temperature-dependent thermal conductivities. In order to accelerate measurements of more than one sample, the proposed method allows for measuring several samples consecutively at each temperature measurement point without adding significant error. We demonstrate the method by performing thermal conductivity measurements on commercial bulk thermoelectric Bi 2 Te 3 samples in the temperature range of 30–150 °C with an error below 3%.

47 OTHER INSTRUMENTATION↗

Assessing the Dosimetric Impact of Real-Time Prostate Motion During Volumetric Modulated Arc Therapy

Purpose: To develop a method for dose reconstruction by incorporating the interplay effect between aperture modulation and target motion, and to assess the dosimetric impact of real-time prostate motion during volumetric modulated arc therapy (VMAT). Methods and Materials: Clinical VMAT plans were delivered with the TrueBeam linac for 8 patients with prostate cancer. The real-time target motion during dose delivery was determined based on the 2-dimensional fiducial localization using an onboard electronic portal imaging device. The target shift in each image was correlated with the control point with the same gantry angle in the VMAT plan. An in-house-developed Monte Carlo simulation tool was used to calculate the 3-dimensional dose distribution for each control point individually, taking into account the corresponding real-time target motion (assuming a nondeformable target with no rotation). The delivered target dose was then estimated by accumulating the dose from all control points in the plan. On the basis of this information, dose–volume histograms and 3-dimensional dose distributions were calculated to assess their degradation from the planned dose caused by target motion. Thirty-two prostate motion trajectories were analyzed. Results: The minimum dose to 0.03 cm{sup 3} of the gross tumor volume (D{sub 0.03cc}) was only slightly degraded after taking motion into account, with a minimum value of 94.1% of the planned dose among all patients and fractions. However, the gross tumor volume receiving prescription dose (V{sub 100%}) could be largely affected by motion, dropping below 60% in 1 trajectory. We did not observe a correlation between motion magnitude and dose degradation. Conclusions: Prostate motion degrades the delivered dose to the target in an unpredictable way, although its effect is reduced over multiple fractions, and for most patients the degradation is small. Patients with greater prostate motion or those treated with stereotactic body radiation therapy would benefit from real-time prostate tracking to reduce the margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance Assessment of a New Gamma Spectroscopy Toolkit: Peak Doctor and the Spectral Nondestructive Assay Platform (SNAP) - 17397

High resolution gamma spectroscopy (HRGS) is a widely used technique for non-destructive characterization of nuclear materials, and assay of radioactive waste. The ability to accurately evaluate raw spectral data is an important step in producing high-quality results. A spectral analysis application known as Peak Doctor has been developed under a Cooperative Research and Development Agreement (CRADA) between LANL and Pajarito Scientific Corporation (PSC). The software has undergone several years of testing and validation by the Radioactive Waste Characterization Team of the LANL Waste Management Services Group (WM-SVS). PeakDoctor is designed to work with the Spectral Nondestructive Assay Platform (SNAP{sup TM}) to provide a complete HRGS analysis engine. SNAP{sup TM} performs model specific corrections for attenuation and geometry. These applications are the major components of a new toolkit designed primarily for portable far-field non-destructive assay. Peak Doctor performs a very accurate peak fit analysis with the goal of improving upon the capabilities of existing commercially available routines. It is designed to be user-configurable and can be customized to any given type of detector and any given type of spectrum. Peak Doctor was developed to resolve many of the inherent complexities in gamma ray spectra including overlapping peaks, complex multiplet regions, large step peaks, backscatter regions and Compton edges. Unlike most spectral analysis platforms, Peak Doctor does not rely on the energy calibration and detector resolution parameters that are saved by the operator in the spectrum file. Instead, key parameters are pre-defined for individual detectors. The software fits a continuum using a series of splines between a series of junctions or 'knots'. Fitting techniques are used to join the splines together to create a near-continuous multi-element curve. Optimizing the location of the knots is one of Peak Doctor's most powerful features. The knots are initially configured using a pre-defined list and are removed or added automatically during the fitting process. Knots are also created when new features are identified such as Step Peaks and Compton Edges. The user can also manually specify knots in order to improve the continuum fit. The initial fit is improved on by removing any outlier regions (which are converted to peaks) and the continuum fitting process is repeated. At this stage, an experienced user can work interactively with the fit by manually converting peak regions to continuum or vice versa. The final step is to fit a series of peaks above the continuum based on detector parameters. Single and multiplet peaks are then processed by either the tailing (piecewise) or non-tailing (Gaussian) Levenberg Marquardt non-linear peak fitting routine depending on the user defined selection. Only a rough knowledge of the detector characteristics (energy calibration and resolution) is required for the fitting process to proceed with good accuracy. Any peaks that are missed can be manually added by the user and will also be fitted. Discontinuities in the peak / continuum fit can be rapidly identified by reviewing the 'residuals scale' plot. For waste streams that are well characterized, it is often the case that routinely encountered spectra will have similar peaks and continuum features. For these cases a handy 'One Step' method is available that proceeds in an automated fashion without user interaction. Peak Doctor has been configured with a set of default spectrum types including plutonium / transuranic waste (including Weapons Grade Pu, Heat Source Pu, Am-241, Am-243 and Np-237), depleted or enriched uranium, nuclear power plant / intermediate level waste (with fission and activation products such as Cs-137 and Co-60) as well as Naturally Occurring Radioactive Materials (NORM). The user can easily add new spectrum types for specific waste streams or other types of radiological / special nuclear materials. The output from PeakDoctor (including net peak area, centroid energy and a list of minimum detectable activity levels at pre-defined regions) is used by SNAP{sup TM} to complete the data analysis process. Isotope activities are calculated using configurable template-driven geometry and attenuation correction methods. The software accounts for matrix and container wall effects, collimator / angular corrections, detector efficiency (based on calibration curves) and stand-off distance. SNAP{sup TM} uses published algorithms incorporating a series of decision points during its operation to allow the analyst to provide logical input to guide the software during the analysis of each unique spectrum. The Peak Doctor / SNAP{sup TM} toolkit has been extensively tested and validated under a variety of conditions using 'benchmark' reference spectra. Test scenarios reported include HPGe-based measurements of well characterized uranium and plutonium standards and radioactive sources with a variety of different geometries and matrix materials including surrogate drums and boxes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗