Vacuum weight-loss and contamination tests of some materials for space application.
Outgassing behavior of polymers in spacecraft by thermal-vacuum weight-loss and contamination tests
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Outgassing behavior of polymers in spacecraft by thermal-vacuum weight-loss and contamination tests
This paper presents a tribological tuft test method of candidate brush seal materials in viewgraph form. The goals of the research are: 1) To develop test method to tribologically brush seal materials; 2) To evaluate materials to identify potential improvements and trends; and 3) Guide seal material development and selection.
The results of an extensive analytical and experimental investigation of the Iosipescu and Asymmetrical Four-Point Bend (AFPB) test methods are summarized. Finite element analyses were used to assess the influence of notch parameters and load locations on the stress state in the specimens. The shear moduli and shear strengths were experimentally measured for quasi-isotropic graphite-epoxy laminates using both the Iosipescu and the AFPB test methods with various combinations of notch parameters and load locations. The test results indicate that changes in the notch geometry and load locations aimed at improving the stress distribution in the test section result in unexpected changes in the failure mode.
The transverse tension fatigue life of S2/8552 glass-epoxy and IM7/8552 carbon-epoxy was characterized using flexure tests of 90-degree laminates loaded in 3-point and 4-point bending. The influence of specimen polishing and specimen configuration on transverse tension fatigue life was examined using the glass-epoxy laminates. Results showed that 90-degree bend specimens with polished machined edges and polished tension-side surfaces, where bending failures where observed, had lower fatigue lives than unpolished specimens when cyclically loaded at equal stress levels. The influence of specimen thickness and the utility of a Weibull scaling law was examined using the carbon-epoxy laminates. The influence of test frequency on fatigue results was also documented for the 4-point bending configuration. A Weibull scaling law was used to predict the 4-point bending fatigue lives from the 3-point bending curve fit and vice-versa. Scaling was performed based on maximum cyclic stress level as well as fatigue life. The scaling laws based on stress level shifted the curve fit S-N characterizations in the desired direction, however, the magnitude of the shift was not adequate to accurately predict the fatigue lives. Furthermore, the scaling law based on fatigue life shifted the curve fit S-N characterizations in the opposite direction from measured values. Therefore, these scaling laws were not adequate for obtaining accurate predictions of the transverse tension fatigue lives.
High-Test Hydrogen Peroxide (HTP) propellant (greater than or equal to 70%) offers many advantages in space launch applications; however, materials used in construction of propulsion systems must be shown to be compatible with HTP. Isothermal Microcalorimetry (IMC) was used to determine the compatibility of several metallic and non-metallic materials with 90% HTP. The results of these experiments agreed with those from immersion bath tests when the values were converted to %Active Oxygen Loss per week (%AOL/wk).
Materials selection for spacecraft is based on conventional flammability or ignition sensitivity acceptance tests. Current procedures for determining the inter-laboratory repeatability and reproducibility of aerospace materials flammability tests are not considering the dependence of data variability on test conditions and consequently attempts to characterize the precision of these methods were not successful. The inter-laboratory data variability is determined with tests conducted under arbitrary conditions, which consequently may not provide sufficient information to enable adequate determination of a method's precision. For evaluating the precision of NASA's flammability test methods, the protocol recommended includes selecting critical parameters and determining the 50% failure point by considering the specific failure criteria of each method using the critical parameter as a variable. Upon performing inter-laboratory round robin testing using this approach, the laboratories' performance could be evaluated by comparing the repeatability of the 50% failure point and/or the repeatability of critical conditions where the probabilities of passing and failing are unity, i.e., the transition zone repeatability. When a sufficient amount of data has been acquired with this method, an adequate estimation of precision of aerospace materials flammability test methods will be possible.
The objective of this research is to modify the well-instrumented standard cone configuration to provide a reproducible bench-scale test environment that simulates the buoyant or ventilation flow that would be generated by or around a burning surface in a spacecraft or extraterrestrial gravity level. We will then develop a standard test method with pass-fail criteria for future use in spacecraft materials flammability screening. (For example, dripping of molten material will be an automatic fail.)
Previous ratings of the compatibility of high test hydrogen peroxide (HTP) with materials are not adequate for current needs. The goal of this work was to develop a new scheme of evaluation of compatibility of HTP with various materials. Procedures were developed to enrich commercially available hydrogen peroxide to 90% concentration and to assay the product. Reactivity testing, accelerated aging of materials and calorimetry studies were done on HTP with representative metallic and non-metallic materials. It was found that accelerated aging followed by concentration determination using refractive index effectively discriminated between different Class 2 metallic materials. Preliminary experiments using Differential Scanning Calorimetry (DSC) suggest that a calorimetry experiment is the most sensitive means to assay the compatibility of HTP with materials.
Hercules IM7/8552 carbon/epoxy and Hysol EA 9394 epoxy adhesive bonded between composite/titanium were tested for permeability after various numbers of thermal cycles between 100 C and liquid nitrogen (-196 C). The specimens were quenched from the 100 C temperature into liquid nitrogen to induce thermal shock into the material. Results showed that the carbon/epoxy system was practically impermeable even after 12 thermal cycles. The EA 9394 adhesive bondline was more permeable than the carbon/epoxy, but vacuum mixing minimized the permeability and kept it within allowable limits. Thermal cycling had little effect on the permeability values of the bondline specimens.
Program develops instrumentation for nondestructive testing of adhesive-bond strength in honeycomb materials and air coupled inspection methods suitable for large tankage.
The short rod chevron-notch specimen has the advantages of (1) crack development at the chevron tip during the early stage of test loading, and (2) convenient calculation of plane-strain fracture toughness from the maximum test load and from a calibration factor which depends only on the specimen geometry and manner of loading. For generalized application, calibration of the specimen over a range of specimen proportions and chevron-notch configurations is necessary. Such was the objective of this investigation, wherein calibration of the short rod specimen was made by means of experimental compliance measurements converted into dimensionless stress intensity factor coefficients.
A new effort geared toward modeling the physics of meteor entry and break-up is underway at NASA Ames Research Center. This is part of a broader interdisciplinary effort on providing physics-based risk assessment models for potentially hazardous objects. As part of the entry modeling task we are seeking to improve our understanding of, among other things, the ablation of meteoric material during high speed entry into earths atmosphere. Meteoroid entry differs greatly in some key respects from spacecraft entry modeling. First, the aerothermal environment at these high velocities (18 km/s) is dominated by radiation. Second, meteoroids less than, say, 50m in size, will likely lose a significant portion of their mass during the high-speed atmospheric entry process due to vaporization as well as melting and spallation. The mass of the object, in turn, directly affects the amount of energy deposited in the atmosphere, and therefore the amount of damage done. Thus it is important for us to understand and be able to model this process in greater detail in order to assess the hazard posed by these objects.In this presentation, we first give an overview of the simple ablation models that are typically used in meteor entry calculations. Additionally, we will present a new model which utilizes a similar approach to what is typically done for spacecraft TPS response modeling. This uses an equilibrium assumption near the surface to compute the ablation rate, as is done in heritage material response codes. Next we describe the radiant heating experiment which uses a high-powered laser to emulate the radiation dominated heating environment experienced by meteoroids during atmospheric entry. The facility the Laser Hardened Material Evaluation Laboratory (LHMEL) permits us to expose samples of meteoritic material to heating rates in excess of 100kW/sq.cm. An overview of the experimental set-up and test plan for the initial exploratory campaign at this facility will be given. Then we present both qualitative and quantitative results from this initial test series. Comparisons between predicted and measured ablation rates suggest that there may be significant blockage of the incident beam by the ablation plume. Furthermore, melt is shown to be a significant ablation mechanics, even at high heating rates (16 kW/sq.cm). Finally, comparisons between the phenomenology of the ablation of terrestrial rocks namely, basalt -- to that of meteorites show very different behavior. This is shown to likely be due in part to the effect of composition on the melt viscosity.
Materials and decontaminate compatibility test in support of anchored interplanetary monitoring platform
Previously derived solutions of fatigue strength as a function of preloading were verified by applying preloads to elevated temperature dynamic fatigue tests of 96 wt% alumina at 1000 C and NC 132 silicon nitride at 1100 C. The technique was found very useful in identification and control of the governing failure mechanism when multiple failure mechanisms, such as slow crack growth, creep and oxidation occurred simultaneously at elevated temperatures.
A new tribological test for candidate brush seal materials evaluation has been developed. The sliding contact between the brush seal wires and their mating counterface journal is simulated by testing a small tuft of wire against the outside diameter of a high speed rotating shaft. The test configuration is similar to a standard block on ring geometry. The new tester provides the capability to measure both the friction and wear of candidate wire and counterface materials under controlled loading conditions in the gram to kilogram range. A wide test condition latitude of speeds (1 to 27 m/s), temperatures (25 to 700 C), and loads (0.5 to 10 N) enables the simulation of many of the important tribological parameters found in turbine engine brush seals. This paper describes the new test rig and specimen configuration and presents initial data for candidate seal materials comparing tuft test results and wear surface morphology to field tested seal components.
A coated columbium alloy material system 0.04 centimeter thick was developed which provides for increased reliability to the load bearing character of the system in the event of physical damage to and loss of the exterior protective coating. The increased reliability to the load bearing columbium alloy (FS-85) was achieved by interposing an oxidation resistant columbium alloy (B-1) between the FS-85 alloy and a fused slurry silicide coating. The B-1 alloy was applied as a cladding to the FS-85 and the composite was fused slurry silicide coated. Results of material evaluation testing included cyclic oxidation testing of specimens with intentional coating defects, tensile testing of several material combinations exposed to reentry profile conditions, and emittance testing after cycling of up to 100 simulated reentries. The clad material, which was shown to provide greater reliability than unclad materials, holds significant promise for use in the thermal protection system of hypersonic reentry vehicles.
Contaminant generation studies were conducted at the component level using two different methods, radioactive tracer technique and gravimetric analysis test procedure. Both of these were reduced to practice during this program. In the first of these methods, radioactively tagged components typical of those used in spacecraft were studied to determine their contaminant generation characteristics under simulated operating conditions. Because the purpose of the work was: (1) to determine the types and quantities of contaminants generated; and (2) to evaluate improved monitoring and detection schemes, no attempt was made to evaluate or qualify specific components. The components used in this test program were therefore not flight hardware items. Some of them had been used in previous tests; some were obsolete; one was an experimental device. In addition to the component tests, various materials of interest to contaminant and filtration studies were irradiated and evaluated for use as autotracer materials. These included test dusts, plastics, valve seat materials, and bearing cage materials.
Nondestructive testing and evaluation of adhesively bonded composite materials with high acoustic attenuation and impedance by acoustic ultrasonic instrument inspection