Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Practical spatial resolution of electron energy loss spectroscopy in aberration corrected scanning transmission elecron microscopy.

The resolution of electron energy loss spectroscopy (EELS) is limited by delocalization of inelastic electron scattering rather than probe size in an aberration corrected scanning transmission electron microscope (STEM). In this study, we present an experimental quantification of EELS spatial resolution using chemically modulated 2 x (LaMnO{sub 3})/2 x (SrTiO{sub 3}) and 2 x (SrVO{sub 3})/2 x (SrTiO{sub 3}) superlattices by measuring the full width at half maxima (FWHM) of integrated Ti M{sub 2,3}, Ti L{sub 2,3}, V L{sub 2,3}, Mn L{sub 2,3}, La N{sub 4,5}, La N{sub 2,3} La M{sub 4,5} and Sr L{sub 3} edges over the superlattices. The EELS signals recorded using large collection angles are peaked at atomic columns. The FWHM of the EELS profile, obtained by curve-fitting, reveals a systematic trend with the energy loss for the Ti, V, and Mn edges. However, the experimental FWHM of the Sr and La edges deviates significantly from the observed experimental tendency. Spatial resolution of aberration corrected STEM/EELS measured for Ti M{sub 2,3}, Ti L{sub 2,3}, V L{sub 2,3}, Mn L{sub 2,3}, La N{sub 4,5}, La N{sub 2,3} La M{sub 4,5} and Sr L{sub 3} edges using oxide superlattices. EELS signals recorded using large collection angles are peaked at atomic columns. The FWHM of the EELS profiles agrees with Egerton's empirical delocalization model for Ti, V, and Mn edges in thin samples. The FWHM of the Sr and La edges is larger than the model's prediction because of scattering by heavy atomic columns.

99 GENERAL AND MISCELLANEOUS↗

Time-Resolved X-Ray Microscopy for Materials Science

X-ray microscopy has been an indispensable tool to image nanoscale properties for materials research. One of its recent advances is extending microscopic studies to the time domain to visualize the dynamics of nanoscale phenomena. Large-scale X-ray facilities have been the powerhouse of time-resolved X-ray microscopy. Their upgrades, including a significant reduction of the X-ray emittance at storage rings (SRs) and fully coherent ultrashort X-ray pulses at free-electron lasers (FELs), will lead to new developments in instrumentation and will open new scientific opportunities for X-ray imaging of nanoscale dynamics with the simultaneous attainment of unprecedentedly high spatial and temporal resolutions. As a result, this review presents recent progress in and the outlook for time-resolved X-ray microscopy in the context of ultrafast nanoscale imaging and its applications to condensed matter physics and materials science.

36 MATERIALS SCIENCE↗

Epi-detected quadruple-modal nonlinear optical microscopy for label-free imaging of the tooth

We present an epi-detected quadruple-modal nonlinear optical microscopic imaging technique (i.e., coherent anti-Stokes Raman scattering (CARS), second-harmonic generation (SHG), third-harmonic generation (THG), and two-photon excited fluorescence (TPEF)) based on a picosecond (ps) laser-pumped optical parametric oscillator system for label-free imaging of the tooth. We demonstrate that high contrast ps-CARS images covering both the fingerprint (500–1800 cm{sup −1}) and high-wavenumber (2500–3800 cm{sup −1}) regions can be acquired to uncover the distributions of mineral and organic biomaterials in the tooth, while high quality TPEF, SHG, and THG images of the tooth can also be acquired under ps laser excitation without damaging the samples. The quadruple-modal nonlinear microscopic images (CARS/SHG/THG/TPEF) acquired provide better understanding of morphological structures and biochemical/biomolecular distributions in the dentin, enamel, and the dentin-enamel junction of the tooth without labeling, facilitating optical diagnosis and characterization of the tooth in dentistry.

60 APPLIED LIFE SCIENCES↗

Smart align -- A new tool for robust non-rigid registration of scanning microscope data

Many microscopic investigations of materials may benefit from the recording of multiple successive images. This can include techniques common to several types of microscopy such as frame averaging to improve signal-to-noise ratios (SNR) or time series to study dynamic processes or more specific applications. In the scanning transmission electron microscope, this might include focal series for optical sectioning or aberration measurement, beam damage studies or camera-length series to study the effects of strain; whilst in the scanning tunnelling microscope, this might include bias voltage series to probe local electronic structure. Whatever the application, such investigations must begin with the careful alignment of these data stacks, an operation that is not always trivial. In addition, the presence of low-frequency scanning distortions can introduce intra-image shifts to the data. Here, we describe an improved automated method of performing non-rigid registration customised for the challenges unique to scanned microscope data specifically addressing the issues of low-SNR data, images containing a large proportion of crystalline material and/or local features of interest such as dislocations or edges. Careful attention has been paid to artefact testing of the non-rigid registration method used, and the importance of this registration for the quantitative interpretation of feature intensities and positions is evaluated.

36 MATERIALS SCIENCE↗

Enhancing the local conductivity of Cu films using temperature-assisted agglomerated Cu nanostructures

We investigate the structural and electrical properties of Cu film and reveal their changes as a function of post-annealing temperature. Thermal annealing of a Cu film on a dielectric substrate can improve its crystallinity; however, high-temperature annealing also leads to a morphological transformation that hinders the precise measurement of electrical properties. The enhanced crystallinity of the Cu films is verified with x-ray diffraction as the annealing temperature increases. To examine the electrical properties of the Cu film after the dewetting processes, which promotes the formation of voids and agglomerations, we utilize both conventional micro four-point probe method as well as an advanced four-point probe scanning tunneling microscopy (4P-STM) technique to measure the conductance and evolution of the microscopic structural properties. We could eliminate a deceptive effect of voids with 4P-STM technique, and disclosed a significantly reduced resistivity (1.88 ± 0.07 µΩ∙cm) of Cu nanostructure after post-annealing at 700 °C. We unveiled impact of crystallinity and imperfections of Cu nanostructure, and discussed the critical role of the twin grain boundaries of single-crystalline Cu (1 1 1) on an Al 2 O 3 substrate. We anticipate that understanding the evolution of the structures and the enhanced electrical properties of the post-annealed Cu nanostructures would be important for nanoscale devices where Cu is used as an interconnecting material and could provide a new route to control the plasmonic applications.

36 MATERIALS SCIENCE↗

CHAMP (Camera, Handlens, and Microscope Probe)

CHAMP (Camera, Handlens And Microscope Probe)is a novel field microscope capable of color imaging with continuously variable spatial resolution from infinity imaging down to diffraction-limited microscopy (3 micron/pixel). As a robotic arm-mounted imager, CHAMP supports stereo imaging with variable baselines, can continuously image targets at an increasing magnification during an arm approach, can provide precision rangefinding estimates to targets, and can accommodate microscopic imaging of rough surfaces through a image filtering process called z-stacking. CHAMP was originally developed through the Mars Instrument Development Program (MIDP) in support of robotic field investigations, but may also find application in new areas such as robotic in-orbit servicing and maintenance operations associated with spacecraft and human operations. We overview CHAMP'S instrument performance and basic design considerations below.

robotic field investigations↗

Reactive sputter deposition of alumina films on magnesium alloy by double cathode glow-discharge plasma technique

In order to overcome the problem of the corrosion resistance of AZ31 magnesium alloy, the nanocrystalline Al{sub 2}O{sub 3} film was deposited on AZ31 magnesium alloy by double cathode glow-discharge plasma technique. The microstructure, chemical composition and elemental chemical state of the sputter-deposited nanocrystalline Al{sub 2}O{sub 3} film were analyzed by means of scanning electron microscopy equipped with an energy dispersive spectroscope, X-ray diffraction), transmission electron microscope and X-ray photoelectron spectroscopy. The results indicated that the sputter-deposited nanocrystalline Al{sub 2}O{sub 3} film consisted of single {theta}-Al{sub 2}O{sub 3} phase with average grain size about 60 nm. The hardness and the elastic modulus of the as-deposited nanocrystalline Al{sub 2}O{sub 3} film were about 17.21 GPa and 217 GPa measured by nanoindentation instrument, respectively. The corrosion behavior of the sputter-deposited nanocrystalline Al{sub 2}O{sub 3} film in 3.5%NaCl solution was investigated by potentiodynamic polarization and electrochemical impedance spectroscopy. The amount of porosity for the sputter-deposited nanocrystalline Al{sub 2}O{sub 3} film calculated by two electrochemical methods was equal to 0.0086% and 0.168%, respectively. The sputter-deposited nanocrystalline Al{sub 2}O{sub 3} film exhibited excellent corrosion resistance, which was attributed to its dense enough structure to prevent magnesium alloy from corrosion in aggressive solutions.

36 MATERIALS SCIENCE↗

Aberration corrected scanning transmission electron microscopy and electron energy loss spectroscopy studies of epitaxial Fe/MgO/(001)Ge heterostructures

Aberration correction in the scanning transmission electron microscope combined with electron energy loss spectroscopy allows simultaneous mapping of the structure, the chemistry and even the electronic properties of materials in one single experiment with spatial resolutions of the order of one Angstrom. Here the authors will apply these techniques to the characterization of epitaxial Fe/MgO/(001)Ge and interfaces with possible applications for tunneling junctions, and the authors will show that epitaxial MgO films can be grown on a (001)Ge substrates by molecular beam epitaxy and how it is possible to map the chemistry of interfaces with atomic resolution. Epitaxial growth of insulator oxides on semiconductors constitutes a key issue within the field of electronics, and a considerably large effort has been devoted to harness the growth of high-k oxides on Si. Ge, due to its high electronic and hole mobility, is a very interesting alternative as a potential substrate for future high performance complementary metal-oxide-semiconductor field-effect transistors. However, a major issue is to avoid the high resistivity at the source and drain contacts ensuing from the pinning of the Fermi level at the valence-band maximum. It has been suggested that this problem could be fixed by depositing a thin insulating tunneling barrier between the Ge substrate and the metal contacts. In this case, single crystal epitaxy would represent an additional benefit, since it would lead to a reduction of interfacial defects and improved performance of the tunneling barrier. MgO has been suggested to fulfill such requisites. Furthermore, MgO has been demonstrated to be a good substrate for epitaxial growth of transition metals thin films, such as Fe and Co, thus avoiding the potential problem of chemical reactivity with Ge. In such a scenario, epitaxial deposition of high quality MgO films on Ge substrates is highly desirable. But in addition, successful epitaxial growth of MgO on a semiconductor would also constitute a plus for applications in spintronics, since the injection of a spin polarized current from a ferromagnetic electrode to a non-magnetic semiconductor requires the presence of a potential barrier. MgO represents a convenient choice because the symmetry filtering properties at the interface with transition metals would allow an efficient spin filtering effect. For this approach to succeed, a suitable semiconducting substrate where MgO can be grown epitaxially must be found. And again, while GaAs and Si have been investigated for such role, Ge has not received much attention so far. In this study the authors report on the atomic resolution characterization of high quality interfaces in Fe/MgO/(001)Ge heterostructures. The study of the defects, the inhomogeneities and the interface structure of such junctions is a must to pave the way toward future applications. For this aim, the combination of scanning transmission electron microscopy (STEM) and electron energy loss spectroscopy (EELS) is a most useful tool, since it allows these features to be probed with atomic resolution. Spherical aberration correction in the STEM allows for increased contrast, allowing even single atoms to be detected both in imaging and spectroscopy.

36 MATERIALS SCIENCE↗

Identification of modes of fracture in a 2618-T6 aluminum alloy using stereophotogrammetry

The identification and the development of a quantification technique of the modes of fracture in fatigue fracture surfaces of a 2618-T6 aluminum alloy were developed during this research. Fatigue tests at room and high temperature (230 Degree-Sign C) were carried out to be able to compare the microscopic fractographic features developed by this material under these testing conditions. The overall observations by scanning electron microscopy (SEM) of the fracture surfaces showed a mixture of transgranular and ductile intergranular fracture. The ductile intergranular fracture contribution appears to be more significant at room temperature than at 230 Degree-Sign C. A quantitative methodology was developed to identify and to measure the contribution of these microscopic fractographic features. The technique consisted of a combination of stereophotogrammetry and image analysis. Stereo-pairs were randomly taken along the crack paths and were then analyzed using the profile module of MeX software. The analysis involved the 3-D surface reconstruction, the trace of primary profile lines in both vertical and horizontal directions within the stereo-pair area, the measurements of the contribution of the modes of fracture in each profile, and finally, the calculation of the average contribution in each stereo-pair. The technique results confirmed a higher contribution of ductile intergranular fracture at room temperature than at 230 Degree-Sign C. Moreover, there was no indication of a direct relationship between this contribution and the strain amplitudes range applied during the fatigue testing. - Highlights: Black-Right-Pointing-Pointer Stereophotogrammetry and image analysis as a measuring tool of modes of fracture in fatigue fracture surfaces. Black-Right-Pointing-Pointer A mixture of ductile intergranular and transgranular fracture was identified at room temperature and 230 Degree-Sign C testing. Black-Right-Pointing-Pointer Development of a quantitative methodology to obtain the percentage of modes of fracture within the fracture surface.

36 MATERIALS SCIENCE↗

CHAMP - Camera, Handlens, and Microscope Probe

CHAMP (Camera, Handlens And Microscope Probe) is a novel field microscope capable of color imaging with continuously variable spatial resolution from infinity imaging down to diffraction-limited microscopy (3 micron/pixel). As an arm-mounted imager, CHAMP supports stereo-imaging with variable baselines, can continuously image targets at an increasing magnification during an arm approach, can provide precision range-finding estimates to targets, and can accommodate microscopic imaging of rough surfaces through a image filtering process called z-stacking. Currently designed with a filter wheel with 4 different filters, so that color and black and white images can be obtained over the entire Field-of-View, future designs will increase the number of filter positions to include 8 different filters. Finally, CHAMP incorporates controlled white and UV illumination so that images can be obtained regardless of sun position, and any potential fluorescent species can be identified so the most astrobiologically interesting samples can be identified.

Mungas, G. S.↗

Multimodal hyperspectral optical microscopy

We describe a unique and convenient approach to multimodal hyperspectral optical microscopy, herein achieved by coupling a portable and transferable hyperspectral imager to various optical microscopes. The experimental and data analysis schemes involved in recording spectrally and spatially resolved fluorescence, dark field, and optical absorption micrographs are illustrated through prototypical measurements targeting selected model systems. Namely, hyperspectral fluorescence micrographs of isolated fluorescent beads are employed to ensure spectral calibration of our detector and to gauge the attainable spatial resolution of our measurements; the recorded images are diffraction-limited. Moreover, spatially over-sampled absorption spectroscopy of a single lipid (18:1 Liss Rhod PE) layer reveals that optical densities on the order of 10-3 may be resolved by spatially averaging the recorded optical signatures. We also briefly illustrate two applications of our setup in the general areas of plasmonics and cell biology. Most notably, we deploy hyperspectral optical absorption microscopy to identify and image algal pigments within a single live Tisochrysis lutea cell. Overall, this work paves the way for multimodal multidimensional spectral imaging measurements spanning the realms of several scientific disciples.

47 OTHER INSTRUMENTATION↗

Atomic-scale friction control by vibration using friction force microscope

Manipulation of friction at the nanoscale has been traditionally approached by chemical means (lubrication). Recent friction force microscopy (FFM) experiments demonstrated that it can be done mechanically by applying vibration to accessible elements of the system. This paper provides analytic understanding on why vibration can reduce friction based on a 1D model imitating the FFM tip moving on a substrate. Open-loop stability is first studied, and a feedback vibration control is then designed using the accessible variable. Comparing to the open-loop system, friction force is significantly reduced in the closed-loop system. Numerical simulations show satisfactory performances.

Guo, Yi↗

Factors influencing quantitative liquid (scanning) transmission electron microscopy

One of the experimental challenges in the study of nanomaterials in liquids in the (scanning) transmission electron microscope ((S)TEM) is gaining quantitative information. A successful experiment in the fluid stage will depend upon the ability to plan for sensitive factors such as the electron dose applied, imaging mode, acceleration voltage, beam-induced solution chemistry changes, and the specifics of solution reactivity. In this paper, we make use of a visual approach to show the extent of damage of different instrumental and experimental factors in liquid samples imaged in the (S)TEM. Previous results as well as new insights are presented to create an overview of beam-sample interactions identified for changing imaging and experimental conditions. This work establishes procedures to understand the effect of the electron beam on a solution, provides information to allow for a deliberate choice of the optimal experimental conditions to enable quantification, and identifies the experimental factors that require further analysis for achieving fully quantitative results in the liquid (S)TEM.

(S)TEM↗

Design and performance of a compact scanning transmission X-ray microscope at the Photon Factory

We present a new compact instrument designed for scanning transmission X-ray microscopy. It has piezo-driven linear stages, making it small and light. Optical components from the virtual source point to the detector are located on a single optical table, resulting in a portable instrument that can be operated at a general-purpose spectroscopy beamline without requiring any major reconstruction. Careful consideration has been given to solving the vibration problem common to high-resolution microscopy, so as not to affect the spatial resolution determined by the Fresnel zone plate. Results on bacteriogenic iron oxides, single particle aerosols, and rare-earth permanent magnets are presented as examples of its performance under diverse applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementing microwave impedance microscopy in a dilution refrigerator

We report the implementation of a dilution refrigerator-based scanning microwave impedance microscope with a base temperature of ∼100 mK. The vibration noise of our apparatus with tuning-fork feedback control is as low as 1 nm. Using this setup, we have demonstrated the imaging of quantum anomalous Hall states in magnetically (Cr and V) doped (Bi, Sb)2Te3 thin films grown on mica substrates. Both the conductive edge modes and topological phase transitions near the coercive fields of Cr- and V-doped layers are visualized in the field-dependent results. Our study establishes the experimental platform for investigating nanoscale quantum phenomena at ultralow temperatures.

Instruments & Instrumentation↗

Real-Time X-Ray Microscopy of Al-Cu Eutectic Solidification

Recent improvements in the resolution of the X-ray Transmission Microscope (XTM) for Solidification Studies provide microstructure feature detectability down to 5 micrometers during solidification. This presentation will show the recent results from observations made in real-time of the solid-liquid interfacial morphologies of the Al-CuAI2 eutectic alloy. Lamellar dimensions and spacings, transitions of morphology caused by growth rate changes, and eutectic grain structures are open to measurements. A unique vantage point viewing the face of the interface isotherm is possible for the first time with the XTM due to its infinite depth of field. A video of the solid-liquid interfaces seen in-situ and in real-time will be shown.

Kaukler, William F.↗

Microscopy of Analogs for Martian Dust and Soil

The upcoming Mars 2001 lander will carry an atomic force microscope (AFM) as part of the Mars Environmental Compatibility Assessment (MECA) payload. By operating in a tapping mode, the AFM is capable of sub-nanometer resolution in three dimensions and can distinguish between substances of different compositions by employing phase-contrast imaging. Phase imaging is an extension of tapping-mode AFM that provides nanometer-scale information about surface composition not revealed in the topography. Phase imaging maps the phase of the cantilever oscillation during the tapping mode scan, hence detecting variations in composition, adhesion, friction, and viscoelasticity. Because phase imaging highlights edges and is not affected by large-scale height differences, it provides for clearer observation of fine features, such as grain edges, which can be obscured by rough topography. To prepare for the Mars 01 mission, we are testing the AFM on a lunar soil and terrestrial basaltic glasses to determine the AFMOs ability to define particle shapes and sizes and grain-surface textures. The test materials include the Apollo 17 soil 79221, which is a mixture of agglutinates, impact and volcanic beads, and mare and highland rock and mineral fragments. The majority of the lunar soil particles are less than 100 microns in size, comparable to the sizes estimated for Martian dust. The terrestrial samples are millimeter size basaltic glasses collected on Black Pointe at Mono Lake, just north of the Long Valley caldera in California. The basaltic glass formed by a phreatomagmatic eruption 13,000 years ago beneath a glacier that covered the Mono Lake region. Because basaltic glass formed by reworking of pyroclastic deposits may represent a likely source for Martian dunes, these basaltic glass samples represent plausible analogs to the types of particles that may be studied in sand dunes by the 01 lander and rover. We have used the AFM to examine several different soil particles at various resolutions. The instrument has demonstrated the ability to identify parallel ridges characteristic of twinning on a 150-micron plagioclase feldspar particle. Extremely small (10-100 nanometer) adhering particles are visible on the surface of the feldspar grain, and appear elongate with smooth surfaces. Phase contrast imaging of the nanometer particles shows several compositions to be present. When the AFM was applied to a 100-micron glass spherule, it was possible to define an extremely smooth surface.E Also visible on the surface of the glass spherule were chains of 100-nanometer- and-smaller impact melt droplets. Additional information is contained in the original extended abstract.

Anderson, M. A.↗

Radiation Dosimetry via Automated Fluorescence Microscopy

A developmental instrument for assessment of radiation-induced damage in human lymphocytes includes an automated fluorescence microscope equipped with a one or more chargecoupled- device (CCD) video camera(s) and circuitry to digitize the video output. The microscope is also equipped with a three-axis translation stage that includes a rotation stage, and a rotary tray that holds as many as thirty specimen slides. The figure depicts one version of the instrument. Once the slides have been prepared and loaded into the tray, the instrument can operate unattended. A computer controls the operation of the stage, tray, and microscope, and processes the digital fluorescence-image data to recognize and count chromosomes that have been broken, presumably by radiation. The design and method of operation of the instrument exploit fluorescence in situ hybridization (FISH) of metaphase chromosome spreads, which is a technique that has been found to be valuable for monitoring the radiation dose to circulating lymphocytes. In the specific FISH protocol used to prepare specimens for this instrument, metaphase lymphocyte cultures are chosen for high mitotic index and highly condensed chromosomes, then several of the largest chromosomes are labeled with three of four differently colored whole-chromosome-staining dyes. The three dyes, which are used both individually and in various combinations, are fluorescein isothiocyanate (FITC), Texas Red (or equivalent), and Cy5 (or equivalent); The fourth dye 4',6-diamidino- 2-phenylindole (DAPI) is used as a counterstain. Under control by the computer, the microscope is automatically focused on the cells and each slide is scanned while the computer analyzes the DAPI-fluorescence images to find the metaphases. Each metaphase field is recentered in the field of view and refocused. Then a four-color image (more precisely, a set of images of the same view in the fluorescent colors of the four dyes) is acquired. By use of pattern-recognition software developed specifically for this instrument, the images in the various colors are processed to recognize the metaphases and count the chromosome fragments of each color within the metaphases. The intermediate results are then further processed to estimate the proportion of cells that have suffered genetic damage. The prototype instrument scans at an average areal rate of 4.7 mm2/h in unattended operation, finding about 14 metaphases per hour. The false-alarm rate is typically less than 3 percent, and the metaphase-miss rate has been estimated to be less than 5 percent. The counts of chromosomes and fragments thereof are 50 to 70 percent accurate.

Castleman, Kenneth R.↗